• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Niveles de calcio sérico y su relación con la presentación de endometritis post puerperal diagnosticada con Metricheck® en vacas lecheras de crianza intensiva de Lima

Arévalo Rodríguez, Irma Karla Cecilia January 2017 (has links)
El documento digital no refiere un asesor / Determina la relación entre el nivel de calcio sérico y la presentación de endometritis en vacas lecheras postparto. El estudio se realiza con 213 vacas lecheras de raza Holstein de 3 establos lecheros de crianza intensiva de la provincia de Lima durante 1 año. Se colectan muestras de sangre de vacas entre el día 1 y 7 postparto. El diagnóstico de endometritis es realizado el día 35±3 postparto empleando el dispositivo Metricheck y de acuerdo al Score McDougall. Las vacas con Score mayor a 1 son positivas a endometritis. Se excluyen del estudio las vacas que murieron antes del diagnóstico de endometritis, vacas que presentan distocia, partos dobles o mortinatos, retención de placenta, metritis puerperal, hipocalcemia clínica o patologías diferentes al de interés y vacas que son tratadas con calcio. El análisis del calcio sérico de las vacas seleccionadas se realiza mediante el empleo de un espectrofotómetro y de un kit de diagnóstico de calcio. El punto de corte determinado mediante análisis de característica operativa del receptor - ROC (NCa vs. Endometritis) es de 7.44 mg/dl. En el análisis de regresión logística se consideran las variables independientes: estación del año, paridad y nivel de calcio (NCa); y la variable dependiente: endometritis. Se determina que las vacas con bajo NCa (<7.44 mg/dl) durante la primera semana postparto tienen mayor riesgo de presentar endometritis comparado con las vacas con alto NCa (>7.44 mg/dl) (OR ajustado=2.58; p<0.05). Las vacas primerizas tienen mayor riesgo de presentar endometritis comparado con vacas multíparas (OR ajustado=8.08; p<0.05). Las vacas que parieron en invierno tienen mayor riesgo de presentar endometritis comparado con vacas que parieron en verano (OR ajustado=2.36; p<0.05). El estudio demuestra que el NCa (<7.44 mg/dl) es un factor de riesgo en la presentación de endometritis en vacas lecheras post parto (p<0.05). / Tesis
2

Efecto climático sobre la producción y la reproducción en los establos lecheros de Lima

Ruíz García, Luis Felipe January 2017 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere un asesor / Evalúa el estrés calórico en el ganado lechero del departamento de Lima y el efecto del índice temperatura-humedad (ITH) sobre el desempeño reproductivo y la producción de leche diaria de las vacas en los establos intensivos. Los estudios se realizaron en cuatro provincias del departamento de Lima: Huaura, Huaral, Lima y Cañete. En el estudio 1 se utilizaron 6512 registros meteorológicos diarios de las estaciones meteorológicas de SENAMHI de las provincias indicadas anteriormente desde enero de 2010 a agosto de 2013. Estos registros se utilizaron para evaluar el estrés calórico en el ganado lechero. Se encontró que el ganado lechero de las localidades de Cañete y Végueta se encontraba más expuesto al estrés por calor. En el estudio 2, 144 registros reproductivos mensuales de cuatro establos lecheros intensivos fueron recolectados desde agosto de 2010 a julio de 2013. Estos datos fueron utilizados para determinar si el incremento del ITH máximo disminuye significativamente la tasa de preñez en los establos lecheros intensivos del departamento de Lima. Se encontró que el incremento del ITH máximo en una unidad disminuía la tasa de preñez de los establos lecheros intensivos en 0.84% (p<0,001). En el estudio 3, 8245 registros productivos de cuatro establos lecheros intensivos fueron recolectados desde agosto de 2010 a julio de 2013. Estos datos fueron utilizados para determinar si el incremento del ITH máximo disminuye significativamente sobre la producción de leche diaria de las vacas en los establos lecheros intensivos del departamento de Lima. Se encontró que el incremento del ITH máximo en una unidad disminuía la producción de leche diaria en 0.356 kg (p<0,001). Se concluye que el estrés calórico es un factor muy importante para la ganadería lechera intensiva del departamento de Lima, que no sólo está presente en los meses de verano, si no que se encuentra presenten en más meses del año, según las condiciones climatológicas de las diferentes provincias y distritos del departamento y que el incremento del ITH ocasiona una disminución significativa del desempeño reproductivo y el nivel productivo de los establos lecheros intensivos del departamento de Lima. / Tesis
3

Combined Energy Systems Applied to Productive Sectors: The Case of Dairy Farms in Central Bolivia / Sistemas Combinados de Energía Aplicados a Sectores Productivos: El Caso de las Granjas Lecheras en Bolivia Central

Villarroel-Schneider, Johnny January 2019 (has links)
Most energy solutions in developing countries focus primarily on solving domestic energy demands of their growing populations without due consideration of sustainable development. On the other hand, in most of these countries, a segment of energy users that has not received enough attention from governments and institutions regarding appropriate energy solutions is the productive sector. This sector is mainly composed by small and medium-sized industries and ventures that greatly contribute to the countries’ economy, as in the case of Bolivia. However, the low investment capacity, the lack of knowledge, training and insufficient support from local and national governments do not allow these solutions to arrive as expected. Although many of these sectors have the potential to apply energy solutions utilizing alternative energy sources, as the waste generated by the activity, this work has not materialized. This is the case of the dairy farmers in central Bolivia, who do not have an adequate management of farm waste. This problem contributes negatively to the contamination of the local and global environment.  This study explores solutions of combined energy systems applied to the dairy sector of Bolivia. The two cases under investigation consider the utilization of waste from farms to produce biogas, which drives the proposed systems. The first solution focuses on a polygeneration system featuring either an internal combustion engine or internally fired microturbine for the simultaneous provision of biogas for cooking, electricity, refrigeration, and fertilizer. The second system involves trigeneration i.e. absorption chiller integrated to an externally fired microturbine for supplying electricity, refrigeration and hot water. Analysis methods include determination of levelized cost of services, payback period, primary energy rates and energy saving rates.  The techno-economic assessment for the polygeneration system shows that the costs of the supplied services are still attractive when compared to subsidized prices of fossil fuel-based services in the market if the investment capital of this system is partially subsidized. The biogas cost from the system is lower than the cost of conventional gas used for cooking. The use of the internal combustion engine results in a lower electricity cost than using the microturbine. The refrigeration cost is slightly higher than conventional refrigeration for both cases. A sensitivity analysis shows that the cost for feedstock (cow dung) can be increased while maintaining an attractive price of biogas, and that subsidies on investment capital cause a reduction in the services costs. In the case of energy performance evaluation of the trigeneration system it was found to be more efficient in terms of energy utilization than conventional fossil fuel-based solutions, and this leads to energy savings.  Finally, it is shown that combined energy systems applied to the Bolivian dairy sector are competitive in terms of their economic feasibility and energy performance. / De flesta energilösningar i utvecklingsländer fokuserar på att lösa inhemska energibehov för sina växande populationer utan att ta hänsyn till hållbar utveckling. Å andra sidan är ett segment av energianvändare den produktiva sektorn, som inte fått tillräckligt med uppmärksamhet från regeringar och institutioner när det gäller lämpliga energilösningar. Denna sektor består huvudsakligen av små och medelstora industrier och företag som i hög grad bidrar till ländernas ekonomi, vilket är fallet med Bolivia. Låg investeringskapacitet, brist på kunskap, utbildning och otillräckligt stöd från lokala och nationella regeringar tillåter dock inte att dessa lösningar kommer fram som förväntat. Även om många av dessa sektorer har potential att tillämpa energilösningar som använder alternativa energikällor, som det avfall som genereras av verksamheten, har detta inte exploaterats i nämnvärd grad. Detta gäller bland annat mjölkbönderna i centrala Bolivia, som inte har en adekvat hantering av jordbruksavfal, vilket bidrar negativt till föroreningar av den lokala och globala miljön. Denna studie undersöker lösningar med kombinerade energisystem för mjölkhantering i Bolivia. De två fall som undersöks gäller användningen av avfall från gårdar för att producera biogas, som driver de föreslagna systemen. Den första lösningen fokuserar på ett polygenerationssystem som innehåller antingen en förbränningsmotor eller mikroturbin med klassisk intern förbränning. Systemet möjliggör samtidig försörjning av biogas för matlagning och elgenerering, bl.a. för kylning samt ger gödningsmedel som restprodukt. Det andra systemet innefattar tri-gereration, dvs en absorptionskylare integrerad med en externt driven mikroturbin för att leverera el, kylning och varmt vatten. Analysmetoder innefattar bestämning av driftkostnader för de olika energitjänsterna, återbetalningsperiod, förbrukad primärenergi och relativ energibesparing. En teknisk-ekonomisk analys av polygenerationssystemet visar att kostnaderna för de tillhandahållna tjänsterna är attraktiva i förhållande till de subventionerade priserna på tjänster på marknaden om subventioner tillämpas på investeringskapitalet. Kostnaden för biogas från systemet är lägre än kostnaden för konventionell gas som används för matlagning. Användning av en förbränningsmotor resulterar i en lägre elkostnad än att använda en mikroturbin. Kylkostnaden är något högre än med konventionell kylning för båda fallen. En känslighetsanalys visar att kostnaden för råvaror (kogödsel) kan tillåtas öka, samtidigt som ett attraktivt biogaspris bibehålls, och att subventioner på investeringskapital leder till en minskning av kostnaderna för energitjänsterna. När det gäller utvärdering av energiprestanda för tri-gererationssystemet visade sig det vara mer effektivt när det gäller energianvändning än konventionella lösningar baserade på fossila bränslen, vilket leder till energibesparingar. Slutligen visas att kombinerade energisystem som tillämpas på mjölkhanteringssektorn är konkurrenskraftiga när det gäller den ekonomiska genomförbarheten och energiprestanda.

Page generated in 0.0452 seconds