1

Massflöde som bedömningsgrund för förorenat grundvatten / Mass flux as a tool for assessment of contaminated groundwater

Stenman, David January 2011 (has links)
Förorenat grundvatten bedöms ofta med fokus på att specifika gränsvärden för föroreningskoncentrationer ej skall överskridas. Höga koncentrationer i grundvattnet behöver dock inte betyda att risken att kontaminera nedströms recipienter är stor. Detta eftersom höga föroreningskoncentrationer kan återfinnas i zoner med låg permeabilitet vilket medför små grundvattenflöden och därmed en liten belastning på nedströms recipienter. Genom att genomföra kompletterande mätningar av masstransporten (massflödet) av en förorening kan dock en tydligare bild av föroreningssituationen fås. I detta arbete undersöktes hur massflöde skulle kunna användas som en bedömningsgrund för förorenat grundvatten och vilka mättekniker som finns för att kvantifiera massflödet. De tekniker som finns för att mäta massflöde kan delas upp i två grupper. Den ena gruppen omfattar tekniker där uppmätta punktdata av koncentrationer och grundvattenflöden interpoleras längs en tvärsnittssektion av marken vinkelrätt mot grundvattenflödet. Den andra gruppen omfattar tekniker där pumpning av grundvatten tillämpas för att bestämma massflödet. Massflödesmätningar av förorenat grundvatten skulle kunna användas vid beslut om vilket eller vilka förorenade områden som skall renas först. Prioriteringar mellan områdena skulle exempelvis kunna baseras på beräknade koncentrationer utifrån massflödesmätningar och storleken på ett potentiellt uttag av grundvatten. Alternativt kan massflödet användas som ett mått på den belastning som anses acceptabel för att koncentrationen i ett närliggande vattendrag inte skall överskrida ett gränsvärde. Mätningar av massflöde skulle då kunna användas som en bedömningsgrund för den belastning av en specifik förorening som anses acceptabel på en recipient från fall till fall. Vid en sådan bedömning måste hänsyn tas till föroreningens farlighet, platsspecifika utspädningseffekter och bakgrundshalter. En fältstudie genomfördes även i ett före detta industriområde i Kopparlunden, Västerås. Fältstudien genomfördes för att exemplifiera hur mätningar av massflöde kan genomföras. Utspädningsteknik tillämpades, med uranin som spårämne, för att skatta specifika grundvattenflöden. Dessa specifika grundvattenflöden kombinerades med tidigare uppmätta TCE-koncentrationer för att erhålla massflödet. I fältstudien skattades massflödet av TCE till ca 29,4 kg år-1. Studier gjorda i USA visar att massflödesmätningar har varit värdefulla då de har underlättat bedömningen av förorenat grundvatten. Studierna visar även att mätningar av massflöde kommer att användas mer frekvent då fördelarna med mätningarna blir mer allmänt kända.
2

Utsättning - från ritning till verklig placering : En kartläggning av fel i produktionsskedet till följd av felaktig utsättning

Smits, Erik, Evensen, Lukas January 2018 (has links)
Layout is a professional term which means to determine the position of construction elements. Layout is done throughout the construction process, it is the stage linking the blueprints to the real placement of the elements such as walls. There are many factors that can cause a less precise measuring, such asbad accuracy, lack of experience, bad weather conditions, or instruments that are not properly maintained. This will affect the construction project both in terms of time and economy. Because of a failing layout, consequences follow for work teams who depend on this being correctly done. Using JM AB as an example, the purpose of this thesis is to investigate the reasons which leads to inaccuracy in the layout process. In order to accomplish a result interviews and a survey has been done. In addition, two on- site visits have been made and research in the company’s economic follow-up for the projects. A possible solution for companies is to come up with a new role which combines two earlier titles into one. If they were to combine the work of a measuring engineer with a supervisor, the role would be more attractive and possible to grow within. Today there’s a lot of personnel who moves on to new challenges and we think that the new role could be a solution to this this problem. Weather conditions is also a problem. Rain, ice formation and strong sun are examples of conditions that creates difficulty for the layout. More research is required in this area.
3

Tillståndsbedömning av krafttransformatorer i stamnätet : En rekommendation av diagnostiska mättekniker

Scheutz Godin, Axel January 2016 (has links)
Ett transformatorfel kan få stora ekonomiska konsekvenser och påverka ett elkraftsystems driftsäkerhet. Genom att övervaka en transformators tillstånd kan haverier och avbrott undvikas. Tillståndsövervakning möjliggör även att förebyggande underhåll kan planeras effektivt. Det här arbetet har undersökt tillgängliga diagnostikmetoder och övervakningstekniker för tillståndsbedömning av transformatorer.  Tillgänglig felstatistik för transformatorer har studerats ingående för att förstå vilka fel som kan uppstå i en transformator och i vilken grad de förekommer. Eftersom felen har olika konsekvenser för transformatorns fortsatta drift har dessa undersökts. Befintliga metoder för att upptäcka fel har dokumenterats. Detta har utförts genom att studera tillgänglig litteratur och via intervjuer med företag som tillverkar övervakningsutrustning för transformatorer. Övervakningsmetoderna har jämförts med avseende på kostnad, livslängd och noggrannhet. Utifrån dessa analyser har en rekommendation tagits fram över vilka övervakningsmetoder som är mest lämpade för Svenska Kraftnät. Det finns verktyg för att kvantifiera resultaten från övervakningsmetoder till lättolkad information. Ett sådant är hälsoindexet, som komprimerar data från olika mätningar, till ett enskilt värde som representerar en komponents tillstånd. En fallstudie har utförts där tre transformatorers tillstånd under perioden 2002–2015 har undersökts med ett befintligt hälsoindex. Resultatet visar att hälsoindex kan utnyttjas för att indikera transformatorernas tillstånd. Nackdelen med hälsoindexet som användes är att indexet är fortsatt högt oavsett kvaliteten på isolationsmaterialet. Därför föreslås en alternativ modell för en hälsoindexberäkning, i vilken pappersåldringen beaktas i större utsträckning. / A transformer fault could affect the reliability of a power system and have serious economic consequences. Therefore there is an increasing demand among electrical utilities to assess the actual condition of their transformers and hence detect faults before they occur. Condition monitoring has the potential to reduce operating costs and improve the reliability of operation. The aim of this master thesis has been to investigate available diagnostic measurement techniques that can assess the condition of power transformers. Transformer failure statistics has been studied in order to understand what different faults that can occur and to which extent they appear. The consequences of different faults have been investigated. Available measurement techniques were coupled with what faults they can detect. The diagnostic measurement techniques have also been compared in regard to cost, lifetime and accuracy. The comparison resulted in a recommendation over which measurement techniques that are most suitable for the Swedish transmission system operator, Svenska Kraftnät. There is a need among electrical utilities of economic and technical justifications for optimal investment and maintenance decisions. One available asset management technique that enables this is the health index. A health index is a tool that combines available measurement data from operating observations, field inspections and laboratory testing into an objective and quantitative index. The index provides information about the overall condition of an asset. A case study has been conducted where an available health index was used to estimate the condition of three transformers. The results indicate that the health index presents an efficient way to represent the condition of transformers. The disadvantage of the used index is that it implies a good condition even when the quality of the transformer insulation paper is poor. An alternative health index is therefore proposed where the paper insulation quality has a larger impact on the index.
4

Monitoring of Partial Discharges on Cable Terminations : An experimental approach to evaluate non-conventional online PD measurement techniques / Övervakning av partiella urladdningar vid kabeländar : En experimentell utvärdering av icke-konventionella mättekniker

Sibo, Tony January 2023 (has links)
The transmission of electric power over long distances has historically posed challenges. However, the advent of high-voltage engineering has not only addressed distance barriers and power losses in electricity transmission and distribution, but it has also significantly improved the efficiency and transmission capacity of power grids. However, the use of high-voltage techniques has presented new challenges in identifying suitable insulator materials capable of withstanding high electrical stresses associated with elevated voltages. A significant issue arising from these extreme electrical stresses is the occurrence of partial discharges (PDs). Those are electrical sparks or pulses in the magnitude order of pico- or nano-coulombs (pC or nC) emitted from high voltage conductors due to the presence of impurities, contaminants or defects in their insulation system. PDs pose a serious threat to the insulation material due to their aggressive nature in breaking down weak points or links inside the insulation system leading to short-circuit and system failure. Means of offline or conventional testing of power assets against partial discharges has proven to be extremely precise but it is often an unavailable option since it requires a total power shutdown. In this paper, the performance of existing online PD detection techniques is tested and evaluated in terms of performance against conventional PD monitoring methods. Five non-intrusive detectors including an infrared camera (IR-camera), an ultrasonic sensor , a temperature and relative humidity sensor (TRH-sensor), high-frequency current transformer (HFCT sensor) and transient earth voltage antenna (TEV-antenna) were tested in a laboratory experiment for detection of PDs emitted by artificially-created defects inside a medium-voltage cable termination. The results showed varying sensitivity levels among the sensors, with the HFCT sensor demonstrating the highest sensitivity to all types and magnitudes of PDs. The IR-camera and ultrasonic sensor also showed potential, while the TRH-sensor exhibited poor sensitivity. The TEV-antenna had limited reliability. The findings of this study are that the HFCT system proved to be highly reliable for online PD monitoring, followed by the IR-camera and ultrasonic sensor, while the TEV-antenna and TRH-sensor showed lower reliability. In future work, further research on testing the HFCT system on-site can be conducted along with performing longer thermographic detection tests using the IR-camera to further investigate their potential in online PD detection. / Överföring av elektrisk kraft över långa avstånd har historiskt sett varit utmanande. Införandet av högspänningsteknik har inte bara övervunnit avståndsbarriärer och effektförluster vid överföring och distribution av elkraft, utan det har också avsevärt förbättrat kraftnätens effektivitet och överföringskapacitet. Användningen av högspänningsteknik har dock också inneburit nya utmaningar såsom utveckling av lämpliga isoleringsmaterial som tål höga elektriska påfrestningar vid höga spänningar. Ett betydande problem som härrör från dessa extrema elektriska spänningar är förekomsten av partiella urladdningar. Dessa urladdningar identifieras vara elektriska gnistor eller pulser i storleksordningen pico- eller nanocoulombs (pC eller nC) som emitteras från högspänningsledare på grund av närvaron av föroreningar eller defekter i närliggande isoleringssystem. PD:er utgör ett allvarligt hot mot isoleringsmaterialet på grund av deras aggressiva natur för att bryta ner svaga punkter eller länkar i isoleringssystemet, vilket kan leda till kortslutningar och systemfel. Konventionella metoder för att testa nätkomponenter mot partiella urladdningar har visat sig vara extremt noggranna, men detta är ofta inte ett tillgängligt alternativ eftersom det kräver ett totalt strömavbrott för att utföras. I denna studie testades och utvärderades prestandan hos befintliga metoder för online-detektering av partiell urladdning i förhållande till konventionella övervakningsmetoder. Fem icke-invasiva detektorer, inklusive en infraröd kamera, en ultraljudssensor, en temperatur- och relativ fuktighetssensor, en högfrekvent strömtransformator och en transient jordspänningsantenn, testades i ett laboratorieexperiment för att upptäcka partiella urladdningar orsakade av artificiellt skapade defekter i en mellanspänningskabelavslutning. Resultaten visade varierande känslighetsnivåer bland sensorerna, där högfrekventa strömtransformatorn visade den högsta känsligheten för alla typer och storlekar av partiella urladdningar. Den infraröda kameran och ultraljudssensorn visade också potential, medan temperatur- och relativ fuktighetssensorn visade låg känslighet. Den transienta jordspänningsantennen hade begränsad tillförlitlighet. Slutsatsen av denna studie är att den högfrekventa strömtransformatorn visade sig vara mycket tillförlitlig för online-övervakning av partiella urladdningar, följt av den infraröda kameran och ultraljudssensorn, medan den transienta jordspänningsantennen, temperatur- och fuktighetssensorn visade lägre tillförlitlighet. I framtida forskning kan ytterligare undersökningar av det högfrekventa strömtransformatorsystemet utföras på plats, tillsammans med längre termografiska detekteringstester med hjälp av den infraröda kameran för att ytterligare undersöka deras potential för onlinedetektering av partiella urladdningar.