• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1751
  • 90
  • 46
  • 11
  • 8
  • 6
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 1929
  • 1380
  • 1232
  • 963
  • 519
  • 517
  • 468
  • 464
  • 261
  • 132
  • 117
  • 110
  • 109
  • 107
  • 101
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
441

Avaliação do músculo pterigóideo lateral por meio de ressonância magnética / Evaluation of the Lateral Pterygoid Muscle by Magnetic Resonance Imaging

D\'Ippolito, Silvia Fernandes Morgado 25 September 2009 (has links)
O Músculo Pterigóideo Lateral (MPL) desempenha um papel importante nas Desordens Temporomandibulares (DTM), devido à íntima relação deste músculo com a Articulação Temporomandibular (ATM). No entanto, evidências de alterações patológicas dos músculos mastigatórios ainda parecem faltar nas pesquisas da DTM. Este estudo investigou o MPL por meio de Ressonância Magnética (RM) de 50 indivíduos com e sem DTM. Neste trabalho, das 100 ATM analisadas, 35 pacientes com DTM (70 ATM), prevalecendo o gênero feminino e 15 indivíduos sem sinais e sintomas clínicos de DTM (30 ATM) foram incluídos. O MPL foi observado e analisado em diferentes projeções. As imagens sagitais oblíquas e axiais da ATM foram capazes de mostrar os MPL claramente. Hipertrofia, atrofia e contratura do MPL foram as anomalias encontradas. Sinais de DTM, como hipermobilidade, hipomobilidade e deslocamento do disco articular puderam ser observados nas imagens de ATM. Com relação aos sintomas clínicos como dor, sons articulares, cefaléia e limitação nos movimentos mandibulares, foi possível observar que todos os pacientes com DTM apresentavam pelo menos um destes sintomas, sendo as queixas mais presentes dor e estalo; e os pacientes sem DTM também puderam mostrar alterações nas imagens de RM da ATM, como atrofia e contratura muscular, as mais observadas. O reconhecimento das alterações no MPL, podem levar a um diagnóstico mais específico e aumentar o entendimento dos sintomas clínicos e da fisiopatologia da DTM. Estudos futuros são necessários para se continuar avaliando o MPL por meio de RM. / The Lateral Pterygoid Muscle (LPM) plays an important role in Temporomandibular Disorders (TMD), due to the close relation of this muscle with the Temporomandibular Joint (TMJ). However, evidence of pathological changes of the masticatory muscles still seems to be lacking in the TMD research. This study investigated the LPM by Magnetic Resonance Imaging (MRI) of 50 subjects with and without TMD. In this work, 100 Temporomandibular joints were analyzed, 35 subjects with TMD (70 TMJs), with the prevalence of female and 15 subjects without clinical signs and symptoms (30 TMJs) were included. The LPM was visible in different projections and analyzed. The oblique sagital and axial images of the TMJ were able to show the LPM clearly. Hipertrophy, atrophy and contracture of the LPM were the abnormalities found. TMD signs, such as hipermobility, hipomobility, disc displacement could be seem in the TMJ images. Related to clinical symptoms like pain, articular sounds, headache, and limitation of mandibular movements, it was possible to observed that all patients with TMD had at least one of these symptoms, pain and click being the most frequent complaint. Patients without TMD could also show alterations in the TMJ MRI, such as atrophy and contracture as the most common. The recognition of LPM alterations may lead to a more specific diagnosis and improvement of understanding of the clinical symptoms and pathophysiology of TMD. Further studies should be necessary to continue evaluating the LPM by MRI.
442

Detecção de fibrose miocárdica pela ressonância magnética cardiovascular em portadores de doença de Chagas: correlação com as formas clínicas e prognóstico / Detection of myocardial fibrosis by cardiovascular magnetic resonance imaging in patients with Chagas disease: correlation with clinical presentation and risk stratification

Lopes, Marly Maria Uellendahl 23 August 2007 (has links)
INTRODUÇÃO: A doença de Chagas (DC) persiste como um importante problema de saúde na América Latina, onde o envolvimento cardíaco é responsável pela elevada morbidade e mortalidade. A identificação dos pacientes de maior risco representa, portanto, um grande desafio. A ressonância magnética cardiovascular (RMC) é uma metodologia de elevada acurácia na avaliação da morfologia e da função ventricular e permite a detecção da fibrose miocárdica pela técnica do realce tardio, podendo ser útil na estratificação de risco dos pacientes chagásicos. OBJETIVOS: Avaliar as características morfológicas e funcionais dos ventrículos esquerdo e direito nas formas clínicas da DC; avaliar a fibrose miocárdica pela RMC e sua relação com as formas clínicas da DC; investigar o valor prognóstico da fibrose miocárdica, através de sua correlação com o escore de Rassi. MÉTODOS: Foram estudados 39 pacientes, sendo 20 do sexo masculino. A população de pacientes foi dividida em dois grupos: com cardiopatia aparente (CCA) e sem cardiopatia aparente (SCA). Todos os pacientes foram submetidos a estudo de RMC para avaliação morfológica e funcional; e detecção da fibrose miocárdica. Visando à obtenção do escore de Rassi, os pacientes realizaram avaliação clínica, eletrocardiograma, radiografia do tórax, ecodopplercardiograma e eletrocardiografia dinâmica de 24 horas (Holter). Os pacientes foram classificados, de acordo com o escore de Rassi, em: de baixo, de médio e de alto risco, e foi realizada a correlação desse escore com os parâmetros obtidos pela RMC. RESULTADOS: Os aspectos morfológicos e funcionais do VE apresentaram uma diferença significante entre as formas clínicas estudadas, e a quantificação de fibrose miocárdica na DC apresentou uma forte correlação com o escore de Rassi (r=0,76 p<0,001). CONCLUSÕES: O ventrículo esquerdo apresentou comprometimento morfológico e funcional no grupo com cardiopatia aparente; a extensão da fibrose miocárdica foi maior no grupo com cardiopatia aparente; a quantificação de fibrose miocárdica pela RMC apresentou forte correlação com o escore de Rassi, denotando o valor prognóstico da RMC nesse grupo de paciente chagásico / INTRODUCTION: Chagas disease (CD) still remains an important health problem in Latin America. One of the major challenges is to identify high risk patients. Considering that magnetic resonance imaging (MRI) has a very high accuracy to assess morphology and ventricular function and that myocardial delayed enhancement (MDE) technique is well established to detect myocardial fibrosis, we believe that MRI may have an important role to stratify patients with CD. OBJECTIVES: Evaluate morphological and functional ventricular characteristics, as well as the extent of myocardial fibrosis (MF) in patients with Chagasdisease, by magnetic resonance imaging (MRI); and search the prognostic value of myocardial fibrosis detected by MRI, comparing these findings with the recently developed Rassi`s score. METHODS: 39 patients were evaluated (male sex = 20), divided in two main groups: a) with apparent cardiomyopathy (AC) and without apparent cardiomyopathy (WAC). All patients were submitted to MRI, using the technique of myocardial delayed enhancement (MDE) and the results were compared with the Rassi`s score (RS), which was obtained by analyzing the following parameters: 12-lead electrocardiogram, chest x-ray, echodopplercardiography and 24-hour dynamic electrocardiography (Holter). Patients were stratified as belonging to the low, medium or high risk group, and then each one was compared with data obtained by MRI. RESULTS: Regarding the morphological and functional analysis, significant differences were observed in both groups (p< 0.001). Furthermore, there was a strong correlation between the extent of myocardial fibrosis and the Rassi`s score (r= 0.76). CONCLUSIONS: MRI is an important technique in the evaluation of patients with CD, stressing morphological and functional differences in all clinical presentations. The strong correlation with the Rassi`s score and the extent of myocardial fibrosis detected by MRI, emphasizes its role in the prognostic stratification of patients with CD
443

Projeto e construção de um equipamento de imagens por ressonância magnética para uso em rotina clínica e em pesquisa / Mri coil design and receiver system for ultra low field magnetic resonance imaging

Vidoto, Edson Luiz Géa 16 March 2001 (has links)
Neste trabalho medidas de condutividade alternada e de corrente versus tensão foram realizadas em dispositivos emissores de luz baseados em poli(2-metoxi-5-(2\'-etil-hexiloxi)-1,4-fenileno vinileno)-MEH-PPV com óxido de zinco (ZnO) como eletrodo transparente e injetor de buracos e alumínio (Al) como eletrodo metálico e injetor de elétrons. MEH-PPV é um derivado do PPV que emite no vermelho. O ZnO tem função trabalho similar à do ITO, mas é menos agressivo ao polímero, menos caro e mais fácil de ser processado. A curva I vs. V retificada mostrou que a corrente direta depende da temperatura. As componentes real e imaginária da condutividade (ac) apresentam comportamento típico de alguns materiais desordenados: a componente imaginária aumenta como função da freqüência e a componente real mostrou-se independente da freqüência para baixas freqüências e varia como uma lei de potência no domínio de freqüências mais altas O modelo de energias livres aleatórias-RFEB e uma resistência em série para o fenômeno de interface foram desenvolvidos e ajustados para os resultados ac. Com base neste ajuste teórico-experimental, obtemos importantes parâmetros do dispositivo, bem como informações quantitativas sobre o fenômeno de transporte no MEH-PPV. / In this work current vs. voltage (I vs. V) and alternating conductivity (ac) measurements were carried out in poly[(2-methoxy- 5-hexyloxy)-pphenylenevinilene] ? MEH-PPV light-emitting diodes having zinc oxide (ZnO) as transparent anode and Al as metallic cathode. MEH-PPV is a PPV derivative, which emits in the red spectral region; ZnO has a work function similar to that of ITO, but it is less aggressive to the polymer, less expensive and easily processed. The retificated I vs. V curves shows that the direct current depends on the temperature. Moreover, the real and imaginary components of alternating conductivity (ac) present typical behavior of somewhat disordered material: the imaginary component grows as a function of the frequency and the real component was observed to be frequency independent for lower frequencies, and follows a power-law above a certain frequency. The Random Energy Free Barrier model approaches and a resistance in series for the interface phenomenon were developed and adjusted for the ac results. From this experimental-theoretical fitting we obtained important parameters of the devices as well as, quantitative informations about the MEH-PPV transport phenomenon.
444

Polarizabilidades elétrica e magnética do próton / Proton\'s electric and magnetic polarizabilities

Onody, Roberto Nicolau 25 April 1979 (has links)
Estimamos os valores das polarizabilidades dipolares elétrica e magnética do próton, levando em conta as contribuições das ressonâncias nucleônicas de menor massa: P33 (1236), P11 (1450), D13 (1525), S11(1550), e da ressonância mesônica &#949 (660). O valor obtido para a soma das polarizabilidades concorda bem com os dados experimentais. Por outro lado, o valor obtido para cada uma delas, que depende do valor não bem determinado da largura do decaimento &#949 &#8594 &#933 &#933, é compatível com os valores experimentais / We have estimated the values of electric and magnetic polarizabilities of the proton, taking into account the contributions of the low masses nucleon ressonances : P33 (1236), P11 (1450), D13 (1525), S11(1550) and the meson ressonance &#949 (660). The obtained value for the sumo f the polarizabilities is in good agreement with the experimental data. On the other hand, the value, of each polarizability, which depends on the not too well determined width decay &#949 &#8594 &#933 &#933, is compatible with experimental values
445

Estudo de condutores iônicos vítreos e poliméricos por ressonância magnética nuclear / Nuclear magnetic resonance study of vitreous and polymeric ionic conductors

Frare Junior, Pedro Luiz 12 September 1996 (has links)
Neste trabalho apresenta-se um estudo por Ressonância Magnética Nuclear (RMN) dos condutores iônicos vítreos (fluoroindatos) e poliméricos, com base nos Poli-Óxidos de Propileno (PPO). Nosso principal objetivo é investigar as propriedades de RMN dos íons responsáveis pela condução iônica nestes condutores amorfos. Entre as propriedades estudadas estão os mecanismos de relaxação nuclear em função da temperatura e freqüência, a forma de linha e o segundo momento associado as linhas de ressonância. No caso dos complexos poliméricos, nossos resultados indicam que a condutividade é governada pelos movimentos segmentários de cadeia polimérica. A análise do segundo momento das linhas, permitiu determinar a intensidade das interações dominantes que estão envolvidas nestes complexos. Dos resultados de relaxação em polímeros, obtivemos os parâmetros importantes do movimento iônico, tais como: a energia de ativação (Ea), a freqüência de saltos (&#9640 e a dependência em freqüência da taxa de relaxação. Nossos resultados refletem a natureza desordenada destes materiais e a complexidade do processo de condução iônica nestes sistemas. Nos estudos realizados em vidros fluorados, pudemos discriminar os mecanismos re relaxação spin-rede presentes. Estes resultados mostram que, abaixo da temperatura de transição vítrea (Tg), T1-1 é fracamente dependente da freqüência e da temperatura. Enquanto que acima de Tg, T1-1 passa a ter um comportamento típico de sistemas termicamente ativados. Um terceiro mecanismo (contribuição paramagnética) foi estudado nas amostras de vidros fluoroindatos dopados com um íon paramagnético (Gd3+), onde pôde se observar das medidas da taxa de relaxação spin-spin (T2-1), o comportamento descrito pela interação hiperfina de contato, entre o núcleo de 19F em difusão com o spin eletrônico do íon paramagnético. Aborda-se ainda, aspectos técnicos necessários a utilização e desenvolvimento do espectrômetro, tais como: sondas de alta e baixa temperaturas, circuitos de recepção e softwares de controle / In this work we report a Nuclear Magnetic Resonance (NMR) study of two types of ionic conductors: fluoroindates glasses and polymers based on polypropylene oxide (PPO). We have investigated the nuclear spin relaxation process of the diffusing ions by measuring relaxation times and the second moment of the resonance line as a function of temperature and frequency. In the case of the polymeric systems our results indicates that the conduction mechanism is d e d by segmental motions of the polymer chain. Analysis of the second moment allow us to determine the intensity of the main interactions involved and, from relaxation measurements, important parameters of the ionic motion can be extracted. Our results are compatible with the complexity of the ionic conduction process characteristic of these disordered systems. Studies realized with the fluoride glass systems allow us to distinguish between the different spin-lattice relaxation mechanisms. Results show that bellow the vitreous transition temperature (Tg), T1-1 has a weak dependence with temperature and frequency. The behavior of T1-1 above Tg is typical of thermally activated systems, from which we could calculate the activation energy. A third mechanism (paramagnetic contribution) was studied in the fluoride glasses doped with (Gd3+). In this case, the spin-spin relaxation process is dominated by the contact hyperfine interaction between diffusing 19F nuclei and the electronic spin of the paramagnetic ion. We still discuss in this work different technical aspects of the NMR spectrometer, such as the low and high temperature probes and software for control and data analysis
446

Ressonância magnética nuclear (1H e 7Li) dos compósitos formados por POE: LiCl04 e aluminas / Nuclear magnetic resonance (1H and 7Li) of the PEO: LiCl04 and alumina composites

Tambelli, Cassio de Campos 02 June 2000 (has links)
Os eletrólitos poliméricos formados com base de poli(óxido de etileno) POE e um sal alcalino, vem sendo motivo de grande interesse científico devido ao seu potencial de aplicações em dispositivos eletroquímicos. A condutividade iônica nestes sistemas resulta do fato que a macromolecula atua como solvente para o sal, deixando-o parcialmente dissociado. Neste trabalho, foi utilizada a técnica de Ressonância Magnética Nuclear (RMN) para caracterizar as dinâmicas do spin nuclear do 1H e do 7Li findando investigar os mecanismos de transporte iônico dos compósitos de eletrólitos poliméricos baseados no POE8:LiC104 e partículas de &3945; e &#947;-alumina. Foram feitas medidas da forma da linha de ressonância e da relaxação spin-rede nas frequências de 36 MHz (1H) e 155,4 MHz (7Li) em função da temperatura no intervalo de 170-350 K. Caracterizações fisicas das partículas foram realizadas através das medidas de tamanho de partícula, porosidade e área superficial. Nos compósitos foram feitas medidas de análise témica por DSC e de condutividade elétrica ac por impedância complexa. Os resultados de RMN do 1H mostraram uma maior mobilidade das cadeias poliméricas para o compósito preparado com a dispersão de 20% de &#945;-Al203 em massa, em relação ao eletrólito polimérico sem partículas. Nenhuma alteração foi observada nas medidas de largura de linha e relaxação spin-rede para os compósitos preparado com 5% de &#945; ou &#947;-alumina. A mobilidade dos íons Li+ apresenta um aumento quando é disperso 20% de &#945;-alumina no complexo polimérico. Em contrapartida, a adição de 20% de &#947;-alumina não altera os valores da taxa de relaxação (1/T1), porém um estreitamento da linha de ressonância em baixas temperaturas, em relação ao complexo polimérico, é observado. Os resultados serão discutido com base nas interações de ácido-base de Lewis / Polymeric electrolytes based on poly(ethylene oxide) (PEO) and alkaline salts has been subject of scientific and technological interest due to its potential applications as solid electrolytes in electrochemical devices. The ionic conductivity of such electrolytes results from the fact that the macromolecule acts as a solvent for the salt, leaving it partially dissociated. Nuclear magnetic resonance (NMR) techniques were used to characterize the 1H and 7Li nuclear spin dynamics in order to investigate the transport properties associated to the ionic conduction mechanisms of polymeric composites based on PEO8:LiC1O4 and particles of &#945; and &#947;-alumina. NMR lineshapes and spin-lattice relaxation were measured at 36 MHz (1 H) and 155.4 MHz (7Li) as a function of temperature in the range of 170-350 K. Physical characterization of the particles was realized by measuring the particle size distribution, porosity and superficial area. Differential scanning calorimetry (DSC) and ac electric conductivity of the composites were measured. 1H NMR results show that the polymeric chains of the composite prepared with 20 wt.% of &#945;-alumina has a greater mobility if compared with the unfilled polymeric material. No changes in linewidth and relaxation rates were observed following the addition of 5 wt.% of &#945; or &#947;-alumina. The 7Li mobility increases when 20 wt.% of &3945;-alumina is added to the starting polymeric material. On the other hand, addition of 20 wt.% of &#947;-alumina do not alter the relaxation rates but produces a small change in linewidth. Results are discussed in accordance with the Lewis acid-base interaction
447

Estudo de polímeros condutores iônicos e eletrônicos dopados com metais alcalinos utilizando-se espectroscopia de alta resolução em sólidos por ressonância magnética multinuclear / Ionic and electronic alkaline metal doped conductive polymer studies using high resolution multinuclear solid-state nuclear magnetic resonance

Giotto, Marcus Vinicius 28 April 1997 (has links)
As técnicas de Espectroscopia de Alta Resolução em Sólidos e Relaxação por RMN são largamente utilizadas no estudo da estrutura e dinâmica de polímeros. Neste trabalho estudamos, utilizando estas técnicas, duas classes distintas de polímeros: os condutores iônicos e os condutores eletrônicos. O polímero condutor iônico estudado foi o Diesterato de Polietileno Glicol (PEGD) complexado com sais de metais alcalinos, LiClO4 ou NaClO4. A metodologia básica que empregamos para o estudo destes materiais foi a análise da forma de linha e do tempo de relaxação longitudinal para os núcleos associados tanto aos portadores de carga, 7Li e 23Na, quanto à cadeia polimérica, 1H e 13C. Todas estas medidas foram realizadas em função da temperatura e da concentração de sal de metal alcalino presente na amostra. Estudos adicionais, por condutividade elétrica, análise térmica e viscosidade foram realizados para complementar o conhecimento obtido por RMN sobre a mobilidade e estrutura das cadeias poliméricas e dos portadores de carga. Os polímeros com ligações de elétrons-\'pi\' conjugados apresentam propriedades eletrônicas especiais, particularmente a condutividade elétrica, e formam uma classe de polímeros condutores eletrônicos que podem ser facilmente oxidados ou reduzidos através de um agente dopante. Estudamos dois polímeros deste tipo: As polianilinas dopadas com 1H ou 7Li. A metodologia básica que empregamos para o estudo destes polímeros foi a análise das formas de linhas espectrais de um dos núcleos que compõem a cadeia polimérica, 13C, e de um dos agentes dopantes, 7Li, em função do método de preparação e da condutividade elétrica, de forma a poder elucidar características estruturais e dinâmicas deste grupo de polímeros. A partir do estudo destas duas classes de polímeros, conseguimos coletar uma quantidade muito grande de resultados experimentais por RMN, a partir de diferentes núcleos atômicos, que contribuíram para elucidar várias de suas características estruturais e dinâmicas / High resolution solid-state NMR spectroscopic techniques are widely used in the study of polymer structure and dynamics. In the present work we are studying, with the employment of these techniques, two distinct kinds of polymers: the ionic conductors and the electronic conductors. The ionic conductor polymer considered was the Poliethyleneglycol Distereate - 400)/MclO4, (M=Li,Na), DPEG/MclO4. The basic methodology employed for the study of these materials were the line shape analysis of the resonance lines and the longitudinal relaxation time, for the nuclei associated with the charge carriers, 7Li and 23Na, and with the polymeric chain, 1H and 13C. The measurements were related to temperature and to the alkali metal salt concentration in the sample. Additional studies, of electrical conductivity, thermal analysis and viscosity were also conducted for the complementation of the information obtained by NMR about the mobility and structure of polymeric chains and the charge carriers. The polymers with conjugated n-electron bounds present special electronic properties, particularly related to the electrical conductivity, and are easily oxidized or reduced by the action of a doping agent. We studied two of these kind of polymers: the 1H and 7Li doped Polyaniline. The basic methodology employed for the study of these polymers was the line shape analysis of the resonance lines related to one of the component nuclei of the polymeric chain, 13C , and the lines related to one of doping agents, 7Li, as a function of the preparation method and the electrical conductivity, as a way of elucidate structural and dynamic characteristics of this class of polymers. From the study of these two classes of polymers we could collect a huge quantity of NMR data from different atomic nuclei, and it led to the elucidation of important structural and dynamic characteristics of the polymers
448

Utilização de um framework PCI Express® em um espectrômetro digital de ressonância magnética / Utilization of a PCI Express® framework in a digital magnetic resonance spectrometer

Martins, Tiago Amaro 23 June 2017 (has links)
O foco central desse trabalho é a utilização e aprimoramento de um framework Peripheral Component Interconnect Express (PCI Express®) para a comunicação de dados em um Espectrômetro Digital de Ressonância Magnética (Digital Magnetic Resonance Spectrometer &#8211; DMRS) utilizando o conceito de Field-Programmable Gate Array (FPGA). Esse trabalho foi desenvolvido para servir como base de comunicação para o Espectrômetro Digital de Ressonância Magnética do Centro de Imagens e Espectroscopia in vivo por Ressonância Magnética (CIERMag) devido ao requerimento de altas taxas de transferência dos dados adquiridos. A integração dessa nova comunicação, entre o software e o hardware do espectrômetro, mantém compatibilidade com as interfaces já existentes possibilitando a execução de todas as sequências desenvolvidas sem nenhuma alteração. A incorporação da comunicação PCI Express provê uma solução com um número menor de etapas por transferência em comparação com a comunicação Ethernet. Com isso é possível aumentar o desempenho do sistema e obter taxas de transferência mais elevadas. Para isso, foram feitas mudanças no hardware de forma a torná-lo mais eficiente, reduzindo o número de ciclos de clock por operação e também a quantidade de lógica sintetizada. Além disso, a latência do software durante as transferências também foi reduzida através da utilização de interrupções Message Signaled Interrupt (MSI) e do método Scatter and Gather usado para reduzir a quantidade de cópias de dados na memória principal do computador. Dessa forma, obteve-se, como resultados reais, uma taxa de transferência efetiva (throughput) de 97% do valor máximo da banda possível do barramento PCI Express. / The central focus of this work is the implementation and use of a Peripheral Component Interconnect Express (PCI Express®) framework for data communication on a Digital Magnetic Resonance Spectrometer (DMRS) using the concept of Field-Programmable Gate Array (FPGA). This work is being developed to serve as a communication basis for the magnetic resonance Digital Spectrometer of the Centro de Imagens e Espectroscopia in vivo por Ressonância Magnética (CIERMag) due to demand of high transfer rates of acquired data. The integration of this new communication, between spectrometer software and hardware, keeps compatibility with existing interfaces, making it possible to execute all developed magnetic resonance sequences without any change. The incorporation of PCI Express communication provides solution with a lower number of steps per transfer when compared to Ethernet communication. By this means it\'s possible to increase system performance and, as result, have higher transfer rates. To accomplish that, the number of clock cycles per operation was reduced, so was the synthesized logic. Furthermore, software latency for data transfer was also reduced consequence of MSI interruption implementation and the use of Scatter and Gather method to remove data movement across the computer main memory. Therefore, it was obtained, as measured real result, a throughput value of 97% the theoretical maximum value for the hardware.
449

Susceptômetro para medidas automáticas da susceptibilidade magnpetica AC / Susceptometer for automatic measures of the AC magnetic susceptibility

Souza, Ruberley Rodrigues de 30 September 1992 (has links)
Foi desenvolvido uma ponte de indutâncias mútuas, auto-balanceada, para medidas automáticas e simultâneas das partes real (x\') e imaginária (x\") da susceptibilidade magnética AC, na faixa de freqüências de 20 Hz e 1 KHz e temperaturas de 2K a 300K. O sistema é balanceado em um elo de realimentação digital que assegura um sinal, em fase e quadratura, continuamente nulo. A amplificação do sinal é feita através de um amplificador \"lock-in\" de duas fases, cujas saídas comandam dois DAC multiplicadores, gerando o sinal composto que é usado para balancear a ponte. O valor absoluto da susceptibilidade é medida movendo as bobinas primária e secundárias de tal forma que a amostra fique posicionada ora em um dos secundários, ora em outro. A resolução da parte numérica é 1 em 4000. A sensibilidade alcançada foi de 10-7 emu para amostras de 10-2cm-3 em um campo de excitação de amplitude 15 Gauss. A interface com um microcomputador ainda não foi desenvolvida. / An automatic self-balanced mutual inductance bridge has been designed to measure the real (x\') and imaginary (x\") parts of the magnetic AC susceptibility simultaneously in the frequency range 20 Hz to 1 KHz and temperatures between 2K to 30OK. The system is based on a digitally controlled feedback loop, which ensures continuous balanced operation, in phase as well in quadrature. The signal amplification chain is made of a dual-phase lock-in amplifier, whose outputs command two DAC multipliers, generating the composite balance signal for nulling the bridge. The absolute value of the susceptibility is measured by moving the primary and secondary coils in such a way to place the sample in the center of both secondary coils. The resolution of the numerical part is 1 in 4000. Sensivities of the order of 10-7 emu for samples of 10-2cm-3 in a primary field of 15 gauss have been obtained. The interface with a desktop computer has not been developed yet.
450

Espectroscopia de prótons na doença de Alzheimer e no comprometimento cognitivo sem demência: avaliação de uma amostra da comunidade / Proton spectroscopy in Alzheimer´s disease and cognitive impairment without dementia: a community study

Azevedo Junior, Dionisio 24 June 2005 (has links)
Para descrever os achados da espectroscopia de prótons (1H-ERM) na doença de Alzheimer (DA) e no comprometimento cognitivo sem demência (CIND) em uma amostra da comunidade foram avaliados 13 pacientes com DA, 12 com CIND e 15 controles normais. A 1H-ERM foi realizada com voxel de 8 cm3 nas regiões temporal direita, parietal esquerda e occipital medial estudando os metabólitos: N-acetilaspartato (NAA), creatina (Cr), colina (Cho) e mio-inositol (mI). O NAA foi maior nos indivíduos controles do que nos DA e intermediário no CIND; o mI foi maior no grupo DA do que nos controles; a Cho mostrou tendência a estar aumentada na DA e CIND. Correlação entre os testes cognitivos e a 1H-ERM confirmou a hipótese de que alterações metabólicas estão presentes quando do aparecimento das primeiras alterações cognitivas. A espectroscopia pode, em função disso, contribuir para o diagnóstico e seguimento de indivíduos com queixa de memória em indivíduos da comunidade com a possibilidade de diagnósticos mais precoces. / For the description of the proton magnetic resonance spectroscopy (1H-ERM) data in Alzheimer´s disease (AD) and Cognitive Impairment Not Dementia (CIND) in a community set, subjects with AD (n=13), CIND (n=12) and normal control (n=15) were investigated. 1H-ERM was performance with single voxel (8 cm3) placed in temporal, parietal e occipital region and studied metabolites: N-acetylaspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mI). NAA concentration was higher in control subjects than AD and intermediated level in CIND patients; mI was higher in patients with AD and CIND; Cho tended to be higher in AD and CIND. Metabolisms changes are present together the first cognitive deficits as showed by correlation between cognitive tests and 1H-ERM. Spectroscopy can be used in the diagnosis and follow-up of individuals with memory complain in the community set with the possibility of early diagnosis

Page generated in 0.0714 seconds