• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 13
  • 12
  • 6
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 107
  • 26
  • 22
  • 21
  • 15
  • 15
  • 15
  • 13
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Accessibility and The Potential of Bio-Physiological Systems Measuring Human Magnetic Fields to Inform Technology Devices

Revalee, Jason S. 25 July 2019 (has links)
No description available.
92

Improved State Estimation for Miniature Air Vehicles

Eldredge, Andrew Mark 02 August 2006 (has links) (PDF)
Research in Unmanned Air Vehicles (UAV's) continues to push the limitations of size and weight. As technical advances have made UAV's smaller and less expensive, they have become more flexible and extensive in their roles. To continue using smaller and less expensive components while retaining and even enhancing performance requires more sophisticated processing of sensor data in order for the UAV to accurately determine its state and thereby allow the use of feedback in controlling the aircraft automatically. This work presents a three-stage state-estimation scheme for the class of UAV's know as Miniature Air Vehicles (MAV's). The first stage estimates pitch and roll, the second stage estimates heading, and the third stage produces a position estimate and an estimate of wind speed and direction. All three stages make use of the extended Kalman filter, a framework for using a system dynamic model to predict future states and to update the predictions using weighted sensor measurements as they become available, where the weighting is based on the relative uncertainty of the dynamic model and the sensors. Using the three-stage state esti-mation scheme, significant improvements in the estimation of pitch, roll and heading have been achieved in simulation and flight testing. Performance of the navigation (position and wind) stage is comparable to an existing baseline algorithms for position and wind, and shows additional promise for use in dead reckoning when GPS updates become unavailable.
93

[pt] DESENVOLVIMENTO DE TRANSDUTORES MAGNÉTICOS EM MALHA FECHADA BASEADOS NO EFEITO DA MAGNETOIMPEDÂNCIA GIGANTE / [en] DEVELOPMENT OF CLOSED LOOP MAGNETIC TRANSDUCERS BASED ON GIANT MAGNETOIMPEDANCE EFFECT

SALVADOR PACHECO 20 September 2021 (has links)
[pt] Esta Tese tem por objetivo o desenvolvimento de um sistema destinado à medição de campo magnético com alta sensibilidade e resolução, baseado nas características de fase da impedância em sensores que apresentam o efeito GMI, e a otimização das características de desempenho por meio do uso de configurações em malha fechada. A metodologia empregada inicia com a avaliação experimental das características de fase da impedância de amostras de diferente estrutura e composição química, em função do campo magnético externo, a fim de selecionar aquelas com alta sensibilidade, baixa histerese e maior homogeneidade. Na sequência, são realizadas avaliações teórico-computacionais dos transdutores magnéticos em malha aberta e fechada (magnetômetro e gradiômetro). Da mesma forma, as principais características dos circuitos e controladores software dos transdutores desenvolvidos são detalhadas ao longo do texto. Por sua vez, as principais figuras de mérito dos protótipos desenvolvidos são detalhadamente analisadas, tais como: sensibilidade, linearidade, resposta em frequência, densidade espectral de ruído e resolução. As caracterizações e ensaios experimentais realizados evidenciaram o grande potencial dos transdutores GMI em malha fechada para a atenuação da interferência 1/f, aprimoramento da linearidade e ampliação da faixa de operação. O magnetômetro GMI em malha fechada apresentou sensibilidade em torno de 75,8 mV/microteslas, fundo de escala maior que mais ou menos 40 microteslas, banda de passagem de 45 Hz e resolução na banda de passagem de 27,74 nT. Por outro lado, o gradiômetro GMI em malha fechada desenvolvido apresentou sensibilidade em torno de 102 mV/microteslas, fundo de escala maior que mais ou menos 40 microteslas, banda de passagem de 30 Hz e resolução na banda de passagem de 28,41 nT. / [en] This Thesis aims to develop a system for magnetic field measurement with high sensitivity and resolution, based on the impedance phase characteristics of sensors that have the GMI effect and the performance characteristics optimization through closed-loop configurations. The methodology starts with the experimental evaluation of the phase characteristics of the impedance in samples of different chemical composition and structure as a function of the external magnetic field in order to select those with high sensitivity, low hysteresis, and higher homogeneity. Subsequently, theoretical-computational assessments of magnetic transducers in open and closed-loop (magnetometer and gradiometer) are carried out. Likewise, the main characteristics of the circuits and software controllers of the developed transducers are detailed throughout the text. In turn, the main figures of merit of the developed prototypes are analyzed in detail, such as sensitivity, linearity, frequency response, noise spectral density, and resolution. The characterizations and experimental tests carried out showed the great potential of GMI transducers in a closed-loop configuration for attenuation of interference 1/f, improving linearity and expanding the operating range. The closed-loop GMI magnetometer showed a sensitivity of around 75.8 mV/microteslas, a full-scale range greater than plus or minus 40 microteslas, a pass band of 45 Hz and a resolution in the pass band of 27.74 nT. On the other hand, the GMI closed-loop gradiometer developed had a sensitivity of around 102 mV/microteslas, a full scale greater than plus or minus 40 microteslas, a passband of 30 Hz and a resolution in the pass band of 28.41 nT.
94

[en] PROPOSAL OF A PORTABLE MULTISENSOR BIOMEDICAL DEVICE FOR DETECTION OF FERROMAGNETIC FOREIGN BODIES / [pt] PROPOSTA DE DISPOSITIVO BIOMÉDICO MULTISENSOR PORTÁTIL PARA LOCALIZAÇÃO DE CORPOS ESTRANHOS FERROMAGNÉTICOS

MELISSA CARVALHO COSTA 21 November 2022 (has links)
[pt] Os procedimentos atuais de localização de corpos estranhos ferromagnéticos utilizados na prática clínica envolvem as técnicas de imageamento de radioscopia e radiografia, que apresentam diversas limitações e riscos. Assim, técnicas de localização baseadas em magnetômetros como SQUID, GMI e GMR têm sido desenvolvidas, com variados graus de complexidade e sucesso. Uma das principais dificuldades de ordem prática, além do custo e das dimensões do sistema de medição no caso do SQUID, que opera a temperaturas criogênicas, é a necessidade de o paciente estar posicionado em uma estrutura móvel de grandes dimensões que permita a determinação das coordenadas da posição bidimensional do mapeamento magnético. Por outro lado, as pequenas dimensões dos sensores GMR ou GMI possibilitam o desenvolvimento de um sistema de medição portátil que poderia integrar outros sensores que em conjunto viabilizem a determinação da posição espacial do sensor magnético em relação ao paciente. Esta dissertação de mestrado investiga técnicas de determinação da posição espacial de um dispositivo portátil, baseado em uma plataforma Raspberry Pi, integrando sensor GMR, câmera, sensores inerciais e um sensor de distância, visando ao futuro desenvolvimento de um protótipo de dispositivo médico portátil para localização de corpos estranhos ferromagnéticos. A pesquisa também investiga técnicas de resolução do problema inverso magnético em tempo real baseadas em filtros de Kalman e ajuste por mínimos quadrados, de modo a acelerar o procedimento diagnóstico na futura aplicação clínica do dispositivo. / [en] The current procedures for locating ferromagnetic foreign bodies used in the clinic involve radioscopy and radiography image techniques, which presents several limitations and risks. Thus, localization techniques based on magnetometers were developed as SQUID, GMI and GMR, with varying degrees of complexity and success. One of the main difficulties, in addition to the cost and dimensions of the system, in the case of the SQUID, which operates at cryogenic temperatures, is the need for the patient to be positioned in a large structure that allows flexibility in the configurations of the two-dimensional position of the magnetic mapping. On the other hand, the small dimensions of the GMR or GMI sensors allow the development of a portable measurement system that could integrate other sensors that together make it possible to determine the spatial position of the magnetic sensor in relation to the patient. This master s dissertation investigates techniques for determining the spatial position of a portable device, based on a Raspberry Pi platform, integrating GMR sensor, camera, inertial sensors and a distance sensor, aiming at the future development of a prototype of a portable medical device for localization of ferromagnetic foreign bodies. The research also investigates real-time inverse magnetic problem solving techniques based on Kalman filters and least squares adjustment, in order to accelerate the diagnostic procedure in the future clinical application of the device.
95

[en] DESIGN OF A SYSTEM FOR DETECTION OF NONFERROMAGNETIC METALLIC FOREIGN BODIES BASED IN EDDY CURRENTS AND GMI MAGNETOMETER / [pt] PROJETO DE SISTEMA DE DETECÇÃO DE CORPOS ESTRANHOS METÁLICOS NÃO-FERROMAGNÉTICOS BASEADO EM EDDY CURRENTS E MAGNETÔMETRO GMI

VINICIUS TOSTES SEIXAS 21 November 2022 (has links)
[pt] Esta dissertação apresenta um projeto de sistema portátil de localização de corpos estranhos metálicos não ferromagnéticos por meio de mapeamento magnético. O sistema baseia-se na indução de correntes parasitas no corpo estranho por um estágio de excitação e na medição por um magnetômetro GMI comercial de elevada resolução (25 pT). A topologia do instrumento é baseada no desacoplamento dos estágios de excitação e medição, com uma configuração que produz linhas de campo magnético primário elevadas na região do corpo estranho e tênues na região do sensor. Esta característica supera as limitações de um instrumento previamente desenvolvido, permitindo aumentar o campo magnético primário de excitação sem saturar o magnetômetro. O projeto é baseado em simulações computacionais, considerando dois tipos de excitação e duas orientações para o eixo de sensibilidade do magnetômetro. Diretrizes internacionais para os limites de exposição à radiação não-ionizante, aspectos biometrológicos, construtivos e elétricos também foram levados em consideração no projeto. A análise de desempenho das configurações mais promissoras confirmou a viabilidade do instrumento de medição proposto, otimizando a operação linear do magnetômetro durante o procedimento de medição e contribuindo para a futura construção de um protótipo de sistema de medição completo, com características de desempenho e segurança asseguradas para a aplicação biomédica pretendida. / [en] This dissertation presents a portable system for the localization of nonferromagnetic foreign metal bodies by magnetic mapping. The system is based on the induction of eddy currents in the foreign body by an excitation stage and the measurement by a high resolution commercial GMI magnetometer (25 pT). The instrument topology is based on the decoupling of the stages of excitation and measurement, with a configuration that produces a high primary magnetic field in the foreign body region and a weak one in the sensor region. This feature surpasses the limitations of a previously developed instrument, allowing to increase the primary excitation magnetic field without saturating the magnetometer. The project is based on computational simulations, considering two types of excitation and two orientations for the magnetometer sensitivity axis. International guidelines for exposure limits to non-ionizing radiation, biometrological, constructive and electrical aspects were also taken into consideration in the project. The performance analysis of the most promising settings confirmed the viability of the proposed measurement instrument, optimizing the linear operation of the magnetometer during the measurement procedure and contributing to the future construction of a complete measurement system prototype, with performance and safety characteristics ensured for the intended biomedical application.
96

High-resolution near-shore geophysical survey using an Autonomous Underwater Vehicle (AUV) with integrated magnetometer and side-scan sonar

Hrvoic, Doug January 2014 (has links)
<p>Small, low cost Autonomous underwater vehicles (AUVs) provide ideal platforms for shallow water survey, as they are capable of unmanned navigation and can be programmed to acquire data at constant depth, or constant altitude above the seabed. AUVs can be deployed under most sea states and are unaffected by vessel motions that often degrade sonar and magnetometer data quality. The integration of sonar and magnetometer sensors on AUV’s is challenging, however, due to limited payload and strong magnetic fields produced by the vehicle motor.</p> <p>In this study, a Marine Magnetics Explorer Overhauser magnetometer was mated to a portable AUV (OceanServer Iver2) creating the first practical AUV- deployed magnetic survey system. To eliminate magnetic interference from the AUV, the magnetometer was tethered to the AUV with a 5 m tow cable, as determined by static and dynamic instrument testing. The results of the magnetic tests are presented, along with field data from a shallow water test area in Lake Ontario near Toronto, Canada. AUV-acquired magnetic survey data were compared directly with a conventional boat-towed magnetic survey of the same area. The AUV magnetic data were of superior quality despite being collected in rough weather conditions that would have made conventional survey impossible. The resulting high-resolution total magnetic intensity and analytic signal maps clearly identify several buried and surface ferrometallic targets that were verified in 500-kHz side- scan sonar imaging and visual inspection by divers.</p> / Master of Science (MSc)
97

Měření vzdálenosti pomocí senzorů mobilního telefonu / Distance measurement using sensors of mobile phone

Hubr, Ivo January 2013 (has links)
Distance and the associated parameters can be measured by specific sensors mobile device. Introduction The work focuses on the description of the sensors and the effects on their accuracy. To measure the distance, there is a number of good practices, which were described and demonstrated the application implemented source code for the Android platform. The project works with a total of three sensors, namely accelerometer, magnetometer and camera. The main objective of this work is the definition and application of methods for measuring distance using the appropriate sensors.
98

Univerzální senzorová testovací platforma / Verastile Sensor-based Experimental Platform

Tydor, Maximilián January 2015 (has links)
This document deals with issues of testing semiconductor inertial sensors like gyroscopes and accelerometers, but also other sensors like magnetometers, inclinometers and others for aviation navigation purposes where strict requirements cover every system. The goal of this thesis is to create modular test platform for testing wide variety of sensors in different combinations under variable circumstances. The development covers mechanical design, electrical design – hardware and also control algorithm – software.
99

[pt] APRENDIZADO PROFUNDO APLICADO NA LOCALIZAÇÃO DE CORPOS ESTRANHOS FERROMAGNÉTICOS EM HUMANOS / [en] DEEP LEARNING APPLIED TO LOCATING FERROMAGNETIC FOREIGN BODIES IN HUMANS

MARCOS ROGOZINSKI 19 January 2022 (has links)
[pt] Corpos estranhos ferromagnéticos inseridos acidentalmente em pacientes geralmente precisam de remoção cirúrgica. Os métodos convencionalmente empregados para localizar corpos estranhos são frequentemente ineficazes devido à baixa precisão na determinação da posição do objeto e representam riscos decorrentes da exposição da equipe médica e dos pacientes à radiação ionizante durante procedimentos de longa duração. Novos métodos utilizando sensores SQUID têm obtido sucesso na localização de corpos estranhos de forma inócua e não invasiva, mas têm a desvantagem de apresentar alto custo e baixa portabilidade. Este trabalho faz parte de pesquisas que buscam trazer maior portabilidade e baixo custo na localização de corpos estranhos no corpo humano utilizando sensores GMI e GMR. O objetivo principal deste trabalho é avaliar e aplicar o uso de Aprendizado Profundo para a localização de corpos estranhos ferromagnéticos no corpo humano utilizando um dispositivo portátil e manual baseado em magnetômetro GMR, incluindo o rastreamento da posição e orientação deste dispositivo a partir de imagens de padrões conhecidos obtidas por uma câmera integrada ao dispositivo e a solução do problema inverso magnético a partir do mapeamento magnético obtido. As técnicas apresentadas se mostraram capazes de rastrear o dispositivo com boa precisão e detectar a localização do corpo estranho com resultados semelhantes ou melhores do que os obtidos em trabalhos anteriores, dependendo do parâmetro. Os resultados obtidos são promissores como base para desenvolvimentos futuros. / [en] Ferromagnetic foreign bodies accidentally inserted in patients usually need to be surgically removed. The methods conventionally employed for locating foreign bodies are often ineffective due to the low accuracy in determining the position of the object and pose risks arising from the exposure of medical staff and patients to ionizing radiation during long-term procedures. New methods using SQUID sensors successfully located foreign bodies in an innocuous and noninvasive way, but they have the drawback of presenting high cost and low portability. This work is part of new research that seeks to bring greater portability and low cost in locating foreign bodies in the human body using GMI and GMR sensors. The main objective of this work is to evaluate and apply the use of Deep Learning in the development of a portable and manual device based on a GMR sensor, including position tracking and orientation of this device from images of known patterns obtained by a camera integrated to the device and the solution of the inverse magnetic problem from the obtained magnetic mapping. The techniques presented are capable of tracking the device with good accuracy and detecting the localization of the foreign body with similar or better results than those obtained in previous works, depending on the parameter. The results obtained are promising as a basis for future developments.
100

[en] HIGH SENSITIVITY TRANSDUCERS FOR MEASURING ARTERIAL PULSE WAVE VELOCITY, BASED ON IMPEDANCE PHASE READINGS OF GMI SENSORS / [pt] TRANSDUTORES DE ALTA SENSIBILIDADE DESTINADOS À MEDIÇÃO DA VELOCIDADE DA ONDA DE PULSO ARTERIAL, BASEADOS NA LEITURA DA FASE DA IMPEDÂNCIA DE SENSORES GMI

LIZETH STEFANÍA BENAVIDES CABRERA 16 November 2021 (has links)
[pt] A velocidade da onda de pulso (VOP) tem sido identificada como o padrão-ouro para avaliação da rigidez arterial e, recentemente, vem sendo reconhecida como um importante indicador no diagnóstico e tratamento de doenças cardiovasculares. Atualmente, já existem dispositivos comerciais capazes de efetuar a medição da VOP, entretanto, ainda exigem um investimento financeiro significativo e alguns requerem um treinamento especializado para seu correto uso. Os, transdutores de pressão atuais são majoritariamente baseados em sensores piezoresistivos, piezoelétricos e capacitivos. Entretanto, pesquisas recentes demostraram que transdutores de pressão que utilizam sensores magnéticos baseados na magnetoimpedância gigante (GMI) apresentam elevada sensibilidade. Tendo em vista que a VOP é um importante indicador do risco de distúrbios cardiovasculares, e considerando os potenciais beneficios dos sensores GMI em relação às demais alternativas, esta tese de doutorado buscou utilizar-se destes elementos sensores a fim de desenvolver um sistema de medição portátil, não-invasivo, de baixo custo, acessível e simples de usar, capaz de efetuar a medição da VOP. Neste intuito, foram desenvolvidos transdutores de alta sensibilidade, baseados nas características de fase da impedância de sensores de Magnetoimpedância Gigante, destinados à medição da velocidade da onda de pulso arterial. A fim de se otimizar as características de desempenho dos transdutores, foram realizadas avaliações teórico-computacionais dos transdutores na configuração em malha aberta e fechada, bem como ensaios experimentais dos protótipos projetados. As caracterizações e ensaios experimentais realizados com o transdutor de pressão em malha aberta resultaram em uma sensibilidade de 59,6 mV/kPa, e resolução de 192,8 Pa para uma média de 30 amostras, na banda de passagem de 1000 Hz. Por outro lado, a configuração em malha fechada apresentou uma sensibilidade de 54,2 mV/kPa, e resolução de 206,0 Pa para uma média de 30 amostras, na banda de passagem de 32 Hz. Tendo em vista os valores de sensibilidade e resolução obtidos, propõe-se empregar o sistema de transdução de pressão que incorpora uma câmara incompressível para amplificação mecânica, na medição de ondas de pulso arterial. Neste protótipo, uma pequena membrana semirrígida localizada na superfície da câmara incompressível é posicionada sobre a superfície da pele, próxima à artéria de interesse. Deste modo, pequenas mudanças de pressão na superfície da pele, causadas pela onda de pulso arterial, provocam uma variação do campo magnético sobre o elemento sensor. Por outra parte, devido à alta sensibilidade apresentada pelo transdutor magnetico (magnetômetro GMI) na configuração de malha aberta (0,2 mV/nT) e de malha fechada (0,19 mV/nT), estes foram usados para medir diretamente a forma de onda do pulso arterial, sem utilizar uma câmara incompressível para transdução mecânica. Nesta medição, considerando a adequada resolução espacial para as demandas anatômicas, utiliza-se um pequeno marcador magnético, envolto por uma fita adesiva hipoalergênica e flexível, aderida á região da pele sobre a artéria de interesse, e aproxima-se o sensor magnético GMI da superfície da pele onde o marcador foi colocado. Finalmente, as configurações propostas foram analisadas e comparadas, a fim de se identificar aquela com melhor desempenho, a qual foi utilizada para medição da VOP. Como o estudo envolve o registro da onda de pulso em participantes da pesquisa, o projeto foi submetido à apreciação e aprovado pela Comissão da Câmara de Ética em Pesquisa da Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) 045/2020 – Protocolo 83/2020. Espera-se que o dispositivo desenvolvido contribua para o avanço tecnológico do ferramental utilizado no setor da saúde. / [en] Pulse wave velocity (PWV) is considered the gold standard for assessing arterial stiffness and recently, it has been recognized as an important indicator in the diagnosis and treatment of cardiovascular disease. Currently, there are commercial devices capable of measuring PWV, however, significant investments are required and some devices requires specialized training for their correct use. Conventional pressure-sensing devices are mainly based on piezoresistive, piezoelectric and capacitive sensors. Recent investigations, however, show that pressure transducer using magnetic sensors based on the giant Magnetoimpedance (GMI) present high-sensitivity. Considering that, PWV is a significant risk factor for future cardiovascular disease and in view of some of the advantages of GMI sensors in relation to another sensing technologies, this doctoral thesis aims to develop a portable measurement system, non-invasive, low-cost, accessible and simple to use, capable of measuring PWV. For this purpose, we have developed a high-sensitivity transducers based on the impedance phase characteristics of GMI sensors, for measuring the arterial pulse wave velocity. In order to improve the performance characteristics of the transducers, computational and theoretical analysis in open and closed loop configuration were performed. The characterizations and experimental tests performed with the open-loop pressure transducer resulted in a sensitivity of 59.6 mV/kPa, and resolution of 192.8 Pa for an average of 30 samples, in the 1000 Hz passband. On the other hand, the closed-loop configuration presented a sensitivity of 54.2 mV/kPa, and a resolution of 206.0 Pa for an average of 30 samples, in the 32 Hz passband. In view of the considerable sensitivity and resolution obtained, it is proposed to employ a pressure transduction system that incorporates an incompressible chamber for mechanical amplification, in the measurement of arterial pulse waves. In this prototype, a small semi-rigid membrane located on the surface of the incompressible chamber is positioned over the surface of the skin, close to the artery of interest. In this way, small pressure changes on the skin surface, caused by the arterial pulse wave, cause a variation of the magnetic field on the sensing element. On the other hand, due to the high sensitivity presented by the magnetic transducer (GMI magnetometer) in the open-loop (0.2 mV/nT) and closed-loop (0.19 mV/nT) configurations, they were used to measure the shape pulse waveform without using an incompressible chamber for mechanical transduction. In this test, considering the adequate spatial resolution for the anatomical demands, a small magnetic marker is used, the magnetic marker is attached to the skin region over the artery of interest, and the GMI magnetic sensor is approached near the marker placed of the skin surface. Finally, the proposed configurations were analyzed and compared in order to identify the one with the best performance, which was used to measure PWV. As the study involves recording the pulse wave in research participants, the project was submitted for consideration and approved by the Research Ethics Committee of the Pontifical Catholic University of Rio de Janeiro (PUC-Rio) 045/2020 – Protocol 83/2020. It is expected that the device developed will contribute to the technological advancement of the tools used in the health sector.

Page generated in 0.0531 seconds