• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nanocompósitos naturais de celulose bacteriana para medicina regenerativa /

Olyveira, Gabriel Molina de. January 2016 (has links)
Orientador: Antônio Carlos Guastaldi / Banca: Sandra Helena Pulcinelli / Banca: Luis Geraldo Vaz / Banca: Jorge Enrique Rodriguez Chanfrau / Banca: Gildásio de Cerqueira Daltro / Resumo: A engenharia de tecidos é um campo que aplica os princípios de engenharia e ciências biológicas para desenvolver substitutos biológicos que restauram, mantém ou melhoram o tecido ou a função do órgão por inteiro. A presente tese estudou arcabouços (scaffolds) produzidos com celulose bacteriana/fosfato de cálcio voltados para a regeneração óssea. Foram analisados a modificação do processo de fermentação da celulose bacteriana com moléculas naturais (sulfato de condroitina e ácido hilaurônico), modificações físicas superficiais empregando-se irradiação gamma na celulose bacteriana e método biomimético para formação de fosfato de cálcio na superfície da membrana, posteriormente foram testados os biomateriais com células do ovário de hamster chineses (CHO-K1 cells). A modificação com moléculas naturais alterou a carga superficial e a cristalinidade das membranas, a modificação física alterou também propriedades físico-químicas de superfície, interferindo no processo de deposição de fosfato de cálcio. Os fosfatos de cálcio testados pelo método biomimético (SBFs 1 e 3), tiveram resultados melhores quanto a sua incorporação na superfíce das membranas não irradiadas de celulose bacteriana e seus nanocompósitos. / Doutor
2

Polímeros biomiméticos nanomagnéticos com acesso restrito (RAMIP magnéticos) obtidos por síntese semicovalente e não covalente visando aplicação em imunossensores e imunoensaios /

Pupin, Rafael Rovatti. January 2017 (has links)
Orientador: Maria del Pilar Taboada Sotomayor / Resumo: A biotina (vitamina B7) pode ser acoplada a diferentes tipos de moléculas e, ainda assim, ser reconhecida seletivamente pelas proteínas avidina e estreptavidina devido à alta constante de afinidade que existe entre elas (Ka = 1,0×1015 L mol-1). Assim, essa interação proporciona excelente aumento na sensibilidade de várias análises; o que leva ao desenvolvimento métodos analíticos para determinação de diferentes compostos que são biotinilados. O uso de materiais biológicos, como anticorpos ou proteínas, em análises de rotina se torna muitas vezes dispendioso e, devido à baixa estabilidade das biomoléculas em condições adversas às mesmas, iniciou-se a síntese de materiais que possam mimetizar as interações biológicas de reconhecimento; o que vem sendo feito com sucesso pelos polímeros molecularmente impressos (MIP). Esses polímeros apresentam vantagens em relação às biomoléculas por possuirem baixo custo, fácil preparação e alta resistência mecânica e térmica. Assim, esta dissertação aborda a síntese, caracterização, otimização e aplicação de diferentes MIP que possuem biotina como molécula alvo. Os estudos iniciais focaram na síntese do MIP magnético (MMIP) com acesso restrito (RAMIP) para realizar exclusão proteica pela modificação do polímero com albumina do soro bovino (BSA) e polietileno glicol (PEG). Enquanto o RAMIP recoberto com BSA não apresentou bons resultados nos experimentos, o RAMIP recoberto com PEG, após otimização, apresentou resultados altamente satisfatórios ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Biotin (vitamin B7) can be attached with different types of molecules and still be selectively recognized by avidin/streptavidin proteins due to the high affinity constant between them (Ka = 1,0×1015 L mol-1). Thus, this interaction provides an excellent increase in the sensitivity of analyzes; which leads to the development of analytical methods for the determination of different biotinylated compounds. The use of biological materials, such as antibodies or proteins, in analyzes is often expensive and has low stability of biomolecules under adverse conditions, which has led to the synthesis of materials that can mimic the biological interactions of recognition; which has been successfully made by molecularly printed polymers (MIP). These polymers have advantages over biomolecules because they have low cost, easy preparation and high mechanical and thermal resistance. Thus, this dissertation explores the synthesis, characterization, optimization and application of different MIP that has biotin as the target molecule. Initial studies focused on the synthesis of magnetic MIP (MMIP) with restricted-access (RAMIP) to evaluate protein exclusion by modifying the polymer with bovine serum albumin (BSA) and polyethylene glycol (PEG). While RAMIP coated with BSA didn't present good results in the experiments, the RAMIP coated with PEG, after optimization, presented highly satisfactory results in protein exclusion (with values ranging from 98 to 99.4% of protein exclusion) and good res... (Complete abstract click electronic access below) / Mestre
3

Desenvolvimento de sensor bioinspirado em hexapeptídeo de enzima acetilcolinesterase para detecção de pesticidas /

Rodrigues, Núbia Fernanda Marinho. January 2018 (has links)
Orientador: Hideko Yamanaka / Coorientador: Flávio Santos Damos / Banca: Cecilio Sadao Fugivara / Banca: Eder Tadeu Gomes Cavalheiro / Banca: Carla dos Santos Riccardi / Banca: Silvia Helena Pires Serrano / Resumo: Os pesticidas estão entre os poluentes mais preocupantes, devido à toxicidade e presença significativa no ambiente. A sua toxicidade é baseada na capacidade de inibir irreversivelmente a enzima acetilcolinesterase (AChE) que é chave na transmissão de impulsos nervosos. Este trabalho descreve o desenvolvimento de sensor contendo hexapeptídeo, bioinspirado em enzima acetilcolinesterase, para detecção de pesticidas organofosforados e carbamatos. A sequência peptídica (NH3+ - His - Glu - Trp - Arg - Pro - Ser - COO-) foi imobilizada sobre nanopartículas magnéticas (Fe3O4) previamente sintetizadas, modificadas com quitosana e posteriormente funcionalizadas com 1,12-diaminododecano. As condições experimentais de imobilização do peptídeo foram otimizadas, sendo estas: concentração 5,0 x 10-5 mol L-1 e tempo de incubação de 30 minutos a 25 ºC. O grupo carboxílico presente na sequência peptídica foi ativado com o uso de agentes de acoplamento 1-etil-3-(3-dimetilaminopropil) carbodiimida (EDC) e N-hidróxisuccinimida (NHS). A razão de concentração otimizada de EDC/NHS foi de 18,6/12,5 mmol L-1, respectivamente, e tempo de ativação de 60 minutos. O sinal eletroquímico do peptídeo foi monitorado pelo pico de oxidação da histidina, cujo valor é diminuído ao interagir com o pesticida. O perclorato de sódio (NaClO4) 0,1 mol L-1 pH 7,5 foi selecionado como eletrólito suporte. Os parâmetros da voltametria de onda quadrada foram otimizados (frequência de 100 Hz, amplitude de 90 mV e incremento ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Pesticides are among the most worrying pollutants due to toxicity and significant presence in the environment. Its toxicity is based on the ability to irreversibly inhibit the enzyme acetylcholinesterase (AChE) which is key in the transmission of nerve impulses. This work describes the development of a sensor containing hexapeptide, bioinspiring enzyme acetylcholinesterase, for the detection of organophosphorus pesticides and carbamates. The peptide sequence (NH3+ - His - Glu - Trp - Arg - Pro - Ser - COO-) was immobilized on previously synthesized magnetic nanoparticles (Fe3O4), modified with chitosan and subsequently functionalized with 1,12 - diaminododecane. The experimental conditions of immobilization of the peptide were optimized, being: 5,0 x 10-5 mol L-1 concentration and incubation time of 30 minutes at 25 ºC. The carboxyl group present in the peptide sequence was activated with the use of 1-ethyl-3- (3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) coupling agents. The optimum concentration ratio of EDC / NHS was 18.6 / 12.5 mmol L-1, respectively, and activation time of 60 minutes. The electrochemical signal of the peptide was monitored by the histidine oxidation peak, whose value is decreased when interacting with the pesticide. Sodium perchlorate (NaClO4) 0.1 mol L-1 pH 7.5 was selected as supporting electrolyte. The parameters of the square wave voltammetry were optimized (frequency of 100 Hz, amplitude of 90 mV and increment of sweep of 6 mV) using a matrix of factorial planning. The preconcentration time of the peptide with the pesticide was fixed in 5 minutes. The sensor presented linear response in the studied concentration ranges, with detection limits of 6.0 x 10-11 mol L-1 and 4.0 x 10- 10 mol L- 1 for carbofuran and chlorpyrifos, respectively. The storage in the refrigerator at ± 4 °C allowed 85% stability of the immobilized peptide after a period of... / Doutor
4

Sensores eletroquímicos à base de nanomateriais carbonáceos e catalisadores biomiméticos para determinação de tetraciclina em diferentes tipos de amostras /

Scontri, Mateus. January 2015 (has links)
Orientador: Maria Del Pilar Taboada Sotomayor / Co-orientador: Ademar Wong / Banca: Gustavo Troinano Feliciano / Banca: Renata Kelly Mendes Valente / Resumo: Este trabalho descreve a preparação e viabilidade de sensores eletroquímicos à base de nanomateriais carbonáceos e catalisadores biomiméticos da enzima P450, visando à obtenção de sensores sensíveis e seletivos para determinação de tetraciclina. Para tal, inicialmente foram construídos sensores eletroquímicos usando pasta de carbono modificada com 10% (m/m) de MWCNT-COOH (nanotubos de carbono de paredes múltiplas funcionalizados com grupos carboxila) e 10% (m/m) de óxido de grafeno (GO). A Voltametria de pulso diferencial adsortiva com varredura anódica (VPDadVA) permitiu obter melhores resultados em solução tampão fosfato 0,1 mol L-1 (pH 7,0); potencial e tempo de acumulação de 0,2 V e 30 s, respectivamente. Sob estas condições o sensor apresentou uma faixa linear de resposta entre 1,2 x 10-5 e 1,7 x 10-4 mol L-1, sensibilidade de 1,2 x 104 (±1,0x103) μA mol L-1 e limite de detecção de 3,6 x 10-8 mol L-1. Este sensor foi aplicado na determinação de tetraciclina em urina sintética, águas de rio e medicamentos, obtendo-se recuperações com valores próximos a 100% e valores de repetibilidade em termos do desvio padrão relativo (DPR) abaixo de 6%. Na segunda etapa do trabalho, visando à obtenção de um sensor biomimético, além dos materiais nanopartículados, as pastas de carbono foram individualmente modificadas, com 11 compostos organometálicos que mimetizam o sitio ativo da enzima P450. Dentre eles, apenas a bispiridilftalocianinaferro (II), cloreto de 5,10,15,20-tetrafenil-21H,23H-porfirinaferro (III) e 1,2,3,4,8,9,10,11,15, 16,17,18,22,23,24,25-hexadecafluoro-29H,31H-ftalocianinacobalto (II) apresentaram resposta promissora usando voltametria cíclica. Entretanto, quando realizados experimentos de quantificação através de VPDadVA nas condições otimizadas, vi nenhum dos sensores mostrou respostas satisfatórias, apesar dos esforços realizados para conseguir a... / Abstract: This work describes the preparation and feasibility of electrochemical sensors based on carbonaceous nanomaterials and biomimetic catalysts of the P450 enzyme, in order to obtain sensitive and selective sensors for determination of tetracycline. For this, electrochemical sensors were initially constructed using carbon paste modified with 10% (w/w) of MWCNTCOOH (carbon nanotubes multi-walled functionalized with carboxyl groups) and 10% (w/w) of graphene oxide (GO). Differential pulse with adsorptive anodic stripping voltammetry (DPadSAV) provided the best results in phosphate buffer 0.1 mol L-1 (pH 7.0) and accumulation potential and time of 0,2 V and 30 s, respectively. Under these conditions the sensor showed a linear response range between 1.2 x 10-5 and 1.7 x 10-4 mol L-1, sensitivity of 1.2 x 104 (± 1,0 x 103) A mol L-1 and detection limit of 3.6 x 10-8 mol L-1. This sensor has been applied to the determination of tetracycline in synthetic urine, river water and pharmaceutical formulations with recovery values close to 100% and repeatability in terms of relative standard deviation (RSD) below 6%. In the second stage of the work in order to obtain a biomimetic sensor, in addition to the nanoparticulate materials, carbon pastes were individually modified, with 11 organometallic compounds that mimic the active site of P450 enzyme. Among them, only bis(pyridil)phthalocyanine iron (II); 5,10,15,20-tetraphenyl-21H, 23H-porphyrin iron (III) chloride and 1,2,3,4,8,9,10,11,15,16,17,18,22,23,24,25-hexadecafluoro-29H,31H-phthalocyanine cobalt (II) showed promising response using cyclic voltammetry. However, when performed experiments by VPD and DPadSAV in optimized conditions, none of the sensors showed satisfactory resposes, despite the efforts made to achieve the quantification of tetracycline. viii Showing that in this case, the these compounds did not improve the sensor response previously obtained... / Mestre
5

Sensores eletroquímicos à base de nanomateriais carbonáceos e catalisadores biomiméticos para determinação de tetraciclina em diferentes tipos de amostras

Scontri, Mateus [UNESP] 24 April 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:10:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-04-24. Added 1 bitstream(s) on 2015-08-20T17:25:48Z : No. of bitstreams: 1 000841964.pdf: 1463703 bytes, checksum: 408f5159b85550b011090a5f648d6c32 (MD5) / Este trabalho descreve a preparação e viabilidade de sensores eletroquímicos à base de nanomateriais carbonáceos e catalisadores biomiméticos da enzima P450, visando à obtenção de sensores sensíveis e seletivos para determinação de tetraciclina. Para tal, inicialmente foram construídos sensores eletroquímicos usando pasta de carbono modificada com 10% (m/m) de MWCNT-COOH (nanotubos de carbono de paredes múltiplas funcionalizados com grupos carboxila) e 10% (m/m) de óxido de grafeno (GO). A Voltametria de pulso diferencial adsortiva com varredura anódica (VPDadVA) permitiu obter melhores resultados em solução tampão fosfato 0,1 mol L-1 (pH 7,0); potencial e tempo de acumulação de 0,2 V e 30 s, respectivamente. Sob estas condições o sensor apresentou uma faixa linear de resposta entre 1,2 x 10-5 e 1,7 x 10-4 mol L-1, sensibilidade de 1,2 x 104 (±1,0x103) μA mol L-1 e limite de detecção de 3,6 x 10-8 mol L-1. Este sensor foi aplicado na determinação de tetraciclina em urina sintética, águas de rio e medicamentos, obtendo-se recuperações com valores próximos a 100% e valores de repetibilidade em termos do desvio padrão relativo (DPR) abaixo de 6%. Na segunda etapa do trabalho, visando à obtenção de um sensor biomimético, além dos materiais nanopartículados, as pastas de carbono foram individualmente modificadas, com 11 compostos organometálicos que mimetizam o sitio ativo da enzima P450. Dentre eles, apenas a bispiridilftalocianinaferro (II), cloreto de 5,10,15,20-tetrafenil-21H,23H-porfirinaferro (III) e 1,2,3,4,8,9,10,11,15, 16,17,18,22,23,24,25-hexadecafluoro-29H,31H-ftalocianinacobalto (II) apresentaram resposta promissora usando voltametria cíclica. Entretanto, quando realizados experimentos de quantificação através de VPDadVA nas condições otimizadas, vi nenhum dos sensores mostrou respostas satisfatórias, apesar dos esforços realizados para conseguir a... / This work describes the preparation and feasibility of electrochemical sensors based on carbonaceous nanomaterials and biomimetic catalysts of the P450 enzyme, in order to obtain sensitive and selective sensors for determination of tetracycline. For this, electrochemical sensors were initially constructed using carbon paste modified with 10% (w/w) of MWCNTCOOH (carbon nanotubes multi-walled functionalized with carboxyl groups) and 10% (w/w) of graphene oxide (GO). Differential pulse with adsorptive anodic stripping voltammetry (DPadSAV) provided the best results in phosphate buffer 0.1 mol L-1 (pH 7.0) and accumulation potential and time of 0,2 V and 30 s, respectively. Under these conditions the sensor showed a linear response range between 1.2 x 10-5 and 1.7 x 10-4 mol L-1, sensitivity of 1.2 x 104 (± 1,0 x 103) A mol L-1 and detection limit of 3.6 x 10-8 mol L-1. This sensor has been applied to the determination of tetracycline in synthetic urine, river water and pharmaceutical formulations with recovery values close to 100% and repeatability in terms of relative standard deviation (RSD) below 6%. In the second stage of the work in order to obtain a biomimetic sensor, in addition to the nanoparticulate materials, carbon pastes were individually modified, with 11 organometallic compounds that mimic the active site of P450 enzyme. Among them, only bis(pyridil)phthalocyanine iron (II); 5,10,15,20-tetraphenyl-21H, 23H-porphyrin iron (III) chloride and 1,2,3,4,8,9,10,11,15,16,17,18,22,23,24,25-hexadecafluoro-29H,31H-phthalocyanine cobalt (II) showed promising response using cyclic voltammetry. However, when performed experiments by VPD and DPadSAV in optimized conditions, none of the sensors showed satisfactory resposes, despite the efforts made to achieve the quantification of tetracycline. viii Showing that in this case, the these compounds did not improve the sensor response previously obtained...

Page generated in 0.1138 seconds