Efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina /

Soares, Luiz Felipe Valandro. January 2005 (has links)
Resumo: Este estudo avaliou o efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina. As hipóteses desse trabalho são que a resistência adesiva não varia após o teste de fadiga e também não varia em função do tipo de pino de fibra. A parte coronária de 60 dentes humanos unirradiculares foi seccionada, obtendo-se espécimes (sp) de 16mm, que foram submetidos à instrumentação endodôntica e então 30 sp foram preparados (12mm) para receber um pino de fibra de quartzo (D.T. Light-Post) [DT] e 30 foram preparados para um pino de fibra de vidro (FRC Postec Plus) [FRC]. Os pinos foram cimentados (All-Bond + cimento resinoso Duolink) e a parte radicular dos sp foi embutida em resina epóxica até 3mm da porção cervical. Foram constituídos 6 grupos (n=10), considerando o tipo de pino de fibra e o regime de ciclagem mecânica (carga: 50 N; 45° em relação ao longo eixo do sp; freqüência: 8Hz): G1- DT + sem ciclagem; G2- DT + 20.000 ciclos; G3- DT + 2.000.000 ciclos; G4- FRC + sem ciclagem; G5- FRC + 20.000 ciclos; G6- FRC + 2.000.000 ciclos. Os sp foram então seccionados perpendicularmente ao longo eixo do sp,obtendo-se fatias de aproximadamente 2mm (4 secções / sp) que foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm.min-1). A média de resistência adesiva das repetições de cada espécime foi obtida e os dados (n=10) foram submetidos à análise estatística (a=0,05). A ANOVA mostrou que: (a) as resistências adesivas do pino DT (7,12 l 2,20 MPa) e do pino FRC (6,87 l 2,12 MPa) foram estatisticamente semelhantes entre si (P=0,665); (b) os valores obtidos para a condição sem ciclagem (6,96 l 2,44 MPa), 20.000 (6,99 l 2,08 MPa) e 2.000.000 (7,02 l 2,00 MPa) foram similares estatisticamente (P=0,996); (c) os 6 grupos foram estatisticamente semelhantes entre si (P=1,000)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of the mechanical cycling on the bond strength of fiber posts resin bonded to root dentin. The tooth crown of the 60 single-rooted human teeth was cut, leaving a 16-mm long root specimens (sp) that were endondontically treated and the space prepared in 12mm. Thirty sp received a quartz fiber post (D.T. Light-Post) and 30 sp received a glass fiber post (FRC Postec Plus). The posts were resin luted in the post space and each sp was embedded with epoxy resin (resin 285, Schaller, Florence, Italy) in a PVC cylinder (height: 25 mm, diameter: 10 mm). Sp were divided into 6 groups, considering the fiber post type and number of the mechanical cycles (load: 50 N; angle of 45°; frequency: 8Hz): G1- DT + without cycling; G2- DT + 20,000 cycles; G3- DT + 2,000,000 cycles; G4- FRC + without cycling; G5- FRC + 20,000 cycles; G6- FRC + 2,000,000 cycles. The sp were cut perpendicular to their long axis, to form 2-mm-thick disk-samples (4 sections / sp), which were submitted to the push-out test (1mm.min-1). The mean bond strength values were calculated for each tooth (n=10) and data were statistical analyzed (a=.05). ANOVA revealed that: (a) the bond strengths of DT (7,12 l 2,20 MPa) and of FRC (6,87 l 2,12 MPa) were statistically similar (P=0,665); (b) the mean values for the "without cycling" groups (6,96 l 2,44 MPa), "20,000 cycles" groups (6,99 l 2,08 MPa) and "2,000,000 cycles" groups (7,02 l 2,00 MPa) were not statistically different (P=0,996); (c) the 6 groups were not statistically different (P=1,000). It was concluded that the mechanical cycling did not affect the bond strength of two fiber posts resin bonded to dentin. / Orientador: Marco Antonio Bottino / Coorientador: Roberto Scotti / Banca: Marco Antonio Bottino / Banca: Alvaro Della Bona / Banca: Mario Fernando de Góes / Banca: Marcos Koiti Itinoche / Banca: Maria Amélia Máximo de Araújo / Doutor
12

Próteses parciais fixas apoiadas sobre conexão dente-implante rígida: análise do comportamento biomecânico antes e após ciclagem mecânica / Tooth-implant supported rigid connected fixed partial dentures: Biomechanical behavior analysis before and after mechanical cycling

Glauber Macedo Rama 10 September 2014 (has links)
A associação entre dente e implante em uma prótese parcial fixa (PPF) vêm sido questionada há muitos anos devido a suas implicações clínicas, incluindo a seleção do melhor tipo de união dos elementos protéticos (conexão rígida ou semi-rígida). Este estudo avaliou próteses dento-implanto-suportadas de conexão rígida do tipo cimentada sobre 3 tipos de conexão protética (hexágono externo - HE, hexágono interno - HI e cone morse - CM) e sua relação com o desajuste vertical e falhas na prótese antes e após ciclagem mecânica, além da análise fotoelástica destas situações. Foram confeccionados 21 corpos de prova (7 HE, 7 HI e 7 CM) sobre um modelo mestre que simulou a perda dentária dos elementos 46 e 47, sendo um implante posicionado na área do 47 e um dente preparado com ligamento periodontal simulado em poliéter na área do 45. Sobre este modelo foram confeccionadas PPFs metalocerâmicas de 3 elementos rígidas cimentadas sobre dente e implante (munhão universal). Os corpos de prova foram preparados e submetidos ao ensaio de ciclagem mecânica com uma carga de 120N por 1.000.000 de ciclos, simulando o uso clínico da prótese por 2 anos. Análises do desajuste vertical foram realizadas por meio de microscopia óptica (40x) em todos os períodos de confecção das PPFs (antes da solda, após solda, após aplicação da cerâmica e após ciclagem). O percentual de falhas nas próteses após ciclagem também foi avaliado (trincas/fraturas/decimentações), além da execução do ensaio fotoelástico (carga pontual dental, bipontual nos pilares e oclusal simultânea). Os resultados obtidos para o desajuste vertical indicaram um aumento significante dos níveis de desajuste para todas as etapas de confecção tanto para dente quanto implante (p<0,0001), porém não significante entre os grupos (p>0,059). Para o percentual de falhas na prótese, encontrou-se um índice decrescente na ordem CM>HI>HE. Para análise fotoelástica, encontrou-se um índice de concentração de tensões crescente na ordem CM&lt;HI&lt;HE. Baseado nos resultados encontrados, dentro das limitações do estudo foi possível concluir que: os níveis de desajuste vertical tendem a aumentar nas etapas de confecção da prótese para todas as conexões protéticas; a fadiga mecânica tende a interferir no grau de desajuste vertical a longo prazo pela deformação da estrutura a depender de sua espessura; o aumento no percentual de falhas da prótese tende a ser proporcional ao aumento da rigidez da conexão protética; apesar da redução da rigidez da conexão protética favorecer a longevidade da PPF, esta também tende a aumentar as tensões nos elementos pilares e stress no osso circundante; a utilização da conexão Morse subcrestal para união dente-implante rígida tende a ser preferível pela preservação dos elementos pilares devido a menor concentração de tensões em detrimento da longevidade da PPF, entretanto esta pode ser substituída caso a falha seja irreversível. / The association between tooth and implant in fixed partial dentures (FPD&prime;s) have been questioned for many years due to its clinical implications, including selecting the best kind of connection design (rigid or semi-rigid connection). This study assessed cemented toothimplant supported rigid connected FPD&prime;s on 3 types of implant connections (external hexagon - EH, internal hexagon - IH and morse taper - MT) and its relationship to the vertical misfit and FPD failure before and after mechanical cycling plus the photoelastic analysis of those situations. 21 specimens (7 EH, 7 IH and 7 MT) were fabricated on a master model that simulated tooth loss of elements 46 and 47, with an implant placed on the 47 area and a prepared tooth with simulated periodontal ligament in polyether on the 45 area. On this model, three-element metalloceramic rigid FPD&prime;s were made, cemented to tooth and implant (universal post). The specimens were prepared and subjected to mechanical cycling with a 120N load under 1,000,000 cycles, simulating a 2-year clinical use of the prosthesis. Analyses of vertical misfit were performed by optical microscopy (40x) in all periods of FPD&prime;s fabrication (before welding, after welding, after application of ceramic and after cycling). The FPD failure percentage after cycling was also evaluated (cracks/fractures/loss of cementation), and photoelastic test was performed (dental load only, simultaneous abutment load and occlusal load). The results for vertical misfit indicated a significant increase in the levels of misfit for all stages of fabrication for both tooth and implant (p<0.0001) but not significant between groups (p>0.059). For the FPD failure percentage, we found a decreasing rate in the order MT>IH>EH. The photoelastic test indicated a major amount of tension increase in the order MT&lt;IH&lt;EH. Based on these results, within the limitations of the study it was concluded that: the levels of vertical misfit tend to increase in the prosthesis fabrication steps for all implant connections; mechanical fatigue tends to interfere on vertical misfit in long term due to deformation of the framework depending on its thickness; the FPD failure percentage tends to be proportional to the rigidity increase of the implant connection; despite the decrease of rigidity of the implant connection favors the longevity of the FPD, this also tends to increase tensions on the abutments and stress on the surrounding bone; the use of subcrestal morse taper connection on rigid tooth-implant FPD&prime;s tends to be preferable for the preservation of the abutments due to the lower abutment stress concentration at the expense of longevity of FPD, though this can be replaced if the failure is irreversible.
13

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Piantino, Marcela Caffarena Junqueira 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.
14

Efeito do material no comportamento mecânico de laminados cerâmicos ultrafinos / The effect of the material on the mechanical behaviour of the ultrathin ceramic laminates

Favero, Stephanie Soares 04 April 2016 (has links)
Objetivos: (1) determinar a carga de fratura e o modo de falha de laminados cerâmicos ultrafinos processados via CAD-CAM em função da microestrutura do material (vitrocerâmica à base de dissilicato de lítio ou porcelana à base de leucita); (2) desenvolver metodologia de ciclagem mecânica para determinar o tempo de vida e o modo de falha de laminados cerâmicos ultrafinos processados via CADCAM. Materiais e métodos: dezesseis dentes humanos, incisivos centrais superiores, foram utilizados para confecção dos espécimes. Os dentes sofreram mínimo preparo, em esmalte, para adequada adaptação dos laminados cerâmicos ultrafinos. Os laminados de dissilicato de lítio e de porcelana foram confeccionados via CAD-CAM e cimentados com cimento resinoso sobre os dentes. Quatro espécimes de cada grupo foram levados à máquina de ensaios universal para determinação da carga de fratura dos laminados. Para o desenvolvimento de metodologia para determinação do tempo de vida dos laminados, uma série de testes piloto foi realizada, utilizando-se diferentes parâmetros como: tipo de antagonista (dentes naturais ou roletes metálicos), carga aplicada (20, 30 ou 40 N) e esquema de ciclo mastigatório (incisão ou deslizamento). Os padrões de falha dos laminados foram analisados em um estereomicroscópio, e os resultados obtidos no ensaio de carga de fratura foram analisados por ANOVA e teste de Tukey. Resultados: o valor médio obtido de carga de fratura para o dissilicato de lítio foi de 431,8 ± 217,9 N, enquanto que para a porcelana foi de 454,4 ± 72,1 N. Não houve diferença estatística entre os valores de carga de fratura encontrados, porém, o desvio padrão e o coeficiente de variação da vitrocerâmica foram muito superiores em relação aos da porcelana. Houve diferença no modo de falha dos materiais testados, sendo que a porcelana apresentou um maior número de falha por lascamento e o dissilicato de lítio apresentou maior quantidade de falha da estrutura dental. Na ciclagem mecânica, para cada condição testada, uma resposta diferente foi obtida. No tipo de ciclo incisão, os antagonistas (dente natural) fraturaram quando as cargas de 30 N e 40 N foram aplicadas. No tipo de ciclo deslizamento, o antagonista (dente natural) sofreu desgaste da borda incisal com carga de 30 N. Para o antagonista rolete metálico, quando a carga de 30 N foi aplicada ocorreu fratura do laminado, e quando aplicada a carga de 20 N, houve desgaste excessivo do rolete metálico. Conclusão: (1) o material utilizado não afetou a carga de fratura dos laminados cerâmicos ultrafinos quando o teste estático foi utilizado. Entretanto, o modo de falha foi significativamente diferente, sendo que a porcelana sofreu mais lascamentos do que o dissilicato de lítio; o qual, por sua vez, apresentou a maioria das falhas relacionadas à estrutura dental. (2) Não foi possível determinar uma combinação de parâmetros de ciclagem mecânica que permitisse a determinação dos parâmetros de fadiga para laminados cerâmicos ultrafinos, já que o número máximo de ciclos alcançados foi de 536.818 ciclos. Dessa forma, estudos futuros precisam ser realizados para que uma metodologia apropriada permita determinar parâmetros de fadiga clinicamente relevantes para laminados cerâmicos ultrafinos em dentes anteriores. / Objectives: (1) to determine the fracture load and the failure mode of the ultra-thin ceramic laminates processed via CAD-CAM according to the microstructure of the material (lithium disilicate-based glass-ceramic or leucite-based porcelain); (2) to develop a fatigue methodology capable of determining the lifetime of ultra-thin ceramic laminates processed via CAD-CAM. Materials and methods: sixteen human maxillary central incisors were used to produce the specimens. The teeth required minimal preparation on the enamel for proper adaptation of the ultra-thin ceramic laminates. Ceramic laminates made of lithium disilicate and feldspathic porcelain with thicknesses between 0.3 mm to 0.5 mm were produced via CAD-CAM and cemented with resin cement. Four specimens of each group were taken to a universal testing machine to determine the fracture load of the laminates. For the development of a fatigue methodology, a series of pilot tests was performed using different parameters such as: type of antagonist (natural teeth or metal roller), applied load (20, 30 or 40 N), and type of masticatory cycle (incision or sliding). Failure modes were analysed using a stereomicroscope. Fracture load data were analysed by ANOVA and Tukey\'s test. Results: the mean fracture load obtained for the glass-ceramic was 431.8 ± 217.9 N, while that obtained for the porcelain was 454.4 ± 72.1 N. There was no statistical difference between the mean fracture load values; however, the standard deviation and the coefficient of the variation of the glass-ceramic were both higher than those obtained for the porcelain. There was also a difference in the failure modes for the two materials tested. The porcelain showed a higher number of factures due to chipping and the lithium disilicate showed a higher number of tooth structure failure. The fatigue experiment showed different results depending on the condition analysed. In the incision cycle, the antagonists (natural tooth) fractured when loads of 30 N and 40 N were applied. In the slide type of cycle, the antagonist (natural tooth) suffered wear on the incisal edge after applying 30 N of load. For the metal roller antagonist, when a 30 N load was applied, the ceramic laminate fractured, and when a 20 N load was applied, an excessive wear of the metal roller occurred. Conclusion: (1) The material used did not affect the fracture load of ultra-thin ceramic laminates when the static test was used. However, the failure mode was significantly different, as porcelain suffered more chipping than the lithium disilicate; which, in turn, showed most fails related to the tooth structure. (2) It was not possible to determine the combination of the mechanical cycling parameters that would allow the determination of fatigue parameters for ultra-thin ceramic laminates, since the maximum number of cycles reached was 536,818 cycles. In this way, future studies need to be carried out so that a clinically relevant methodology can be developed to determine the fatigue parameters of ultra-thin ceramic laminates in the anterior teeth.
15

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Marcela Caffarena Junqueira Piantino 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.
16

Efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina

Soares, Luiz Felipe Valandro [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 soares_lfv_dr_sjc.pdf: 2172167 bytes, checksum: afe324626620aad27736c29fa48ab77b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina. As hipóteses desse trabalho são que a resistência adesiva não varia após o teste de fadiga e também não varia em função do tipo de pino de fibra. A parte coronária de 60 dentes humanos unirradiculares foi seccionada, obtendo-se espécimes (sp) de 16mm, que foram submetidos à instrumentação endodôntica e então 30 sp foram preparados (12mm) para receber um pino de fibra de quartzo (D.T. Light-Post) [DT] e 30 foram preparados para um pino de fibra de vidro (FRC Postec Plus) [FRC]. Os pinos foram cimentados (All-Bond + cimento resinoso Duolink) e a parte radicular dos sp foi embutida em resina epóxica até 3mm da porção cervical. Foram constituídos 6 grupos (n=10), considerando o tipo de pino de fibra e o regime de ciclagem mecânica (carga: 50 N; 45° em relação ao longo eixo do sp; freqüência: 8Hz): G1- DT + sem ciclagem; G2- DT + 20.000 ciclos; G3- DT + 2.000.000 ciclos; G4- FRC + sem ciclagem; G5- FRC + 20.000 ciclos; G6- FRC + 2.000.000 ciclos. Os sp foram então seccionados perpendicularmente ao longo eixo do sp,obtendo-se fatias de aproximadamente 2mm (4 secções / sp) que foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm.min-1). A média de resistência adesiva das repetições de cada espécime foi obtida e os dados (n=10) foram submetidos à análise estatística (a=0,05). A ANOVA mostrou que: (a) as resistências adesivas do pino DT (7,12 l 2,20 MPa) e do pino FRC (6,87 l 2,12 MPa) foram estatisticamente semelhantes entre si (P=0,665); (b) os valores obtidos para a condição sem ciclagem (6,96 l 2,44 MPa), 20.000 (6,99 l 2,08 MPa) e 2.000.000 (7,02 l 2,00 MPa) foram similares estatisticamente (P=0,996); (c) os 6 grupos foram estatisticamente semelhantes entre si (P=1,000)... / This study evaluated the effect of the mechanical cycling on the bond strength of fiber posts resin bonded to root dentin. The tooth crown of the 60 single-rooted human teeth was cut, leaving a 16-mm long root specimens (sp) that were endondontically treated and the space prepared in 12mm. Thirty sp received a quartz fiber post (D.T. Light-Post) and 30 sp received a glass fiber post (FRC Postec Plus). The posts were resin luted in the post space and each sp was embedded with epoxy resin (resin 285, Schaller, Florence, Italy) in a PVC cylinder (height: 25 mm, diameter: 10 mm). Sp were divided into 6 groups, considering the fiber post type and number of the mechanical cycles (load: 50 N; angle of 45°; frequency: 8Hz): G1- DT + without cycling; G2- DT + 20,000 cycles; G3- DT + 2,000,000 cycles; G4- FRC + without cycling; G5- FRC + 20,000 cycles; G6- FRC + 2,000,000 cycles. The sp were cut perpendicular to their long axis, to form 2-mm-thick disk-samples (4 sections / sp), which were submitted to the push-out test (1mm.min-1). The mean bond strength values were calculated for each tooth (n=10) and data were statistical analyzed (a=.05). ANOVA revealed that: (a) the bond strengths of DT (7,12 l 2,20 MPa) and of FRC (6,87 l 2,12 MPa) were statistically similar (P=0,665); (b) the mean values for the without cycling groups (6,96 l 2,44 MPa), 20,000 cycles groups (6,99 l 2,08 MPa) and 2,000,000 cycles groups (7,02 l 2,00 MPa) were not statistically different (P=0,996); (c) the 6 groups were not statistically different (P=1,000). It was concluded that the mechanical cycling did not affect the bond strength of two fiber posts resin bonded to dentin.
17

Efeito do material no comportamento mecânico de laminados cerâmicos ultrafinos / The effect of the material on the mechanical behaviour of the ultrathin ceramic laminates

Stephanie Soares Favero 04 April 2016 (has links)
Objetivos: (1) determinar a carga de fratura e o modo de falha de laminados cerâmicos ultrafinos processados via CAD-CAM em função da microestrutura do material (vitrocerâmica à base de dissilicato de lítio ou porcelana à base de leucita); (2) desenvolver metodologia de ciclagem mecânica para determinar o tempo de vida e o modo de falha de laminados cerâmicos ultrafinos processados via CADCAM. Materiais e métodos: dezesseis dentes humanos, incisivos centrais superiores, foram utilizados para confecção dos espécimes. Os dentes sofreram mínimo preparo, em esmalte, para adequada adaptação dos laminados cerâmicos ultrafinos. Os laminados de dissilicato de lítio e de porcelana foram confeccionados via CAD-CAM e cimentados com cimento resinoso sobre os dentes. Quatro espécimes de cada grupo foram levados à máquina de ensaios universal para determinação da carga de fratura dos laminados. Para o desenvolvimento de metodologia para determinação do tempo de vida dos laminados, uma série de testes piloto foi realizada, utilizando-se diferentes parâmetros como: tipo de antagonista (dentes naturais ou roletes metálicos), carga aplicada (20, 30 ou 40 N) e esquema de ciclo mastigatório (incisão ou deslizamento). Os padrões de falha dos laminados foram analisados em um estereomicroscópio, e os resultados obtidos no ensaio de carga de fratura foram analisados por ANOVA e teste de Tukey. Resultados: o valor médio obtido de carga de fratura para o dissilicato de lítio foi de 431,8 ± 217,9 N, enquanto que para a porcelana foi de 454,4 ± 72,1 N. Não houve diferença estatística entre os valores de carga de fratura encontrados, porém, o desvio padrão e o coeficiente de variação da vitrocerâmica foram muito superiores em relação aos da porcelana. Houve diferença no modo de falha dos materiais testados, sendo que a porcelana apresentou um maior número de falha por lascamento e o dissilicato de lítio apresentou maior quantidade de falha da estrutura dental. Na ciclagem mecânica, para cada condição testada, uma resposta diferente foi obtida. No tipo de ciclo incisão, os antagonistas (dente natural) fraturaram quando as cargas de 30 N e 40 N foram aplicadas. No tipo de ciclo deslizamento, o antagonista (dente natural) sofreu desgaste da borda incisal com carga de 30 N. Para o antagonista rolete metálico, quando a carga de 30 N foi aplicada ocorreu fratura do laminado, e quando aplicada a carga de 20 N, houve desgaste excessivo do rolete metálico. Conclusão: (1) o material utilizado não afetou a carga de fratura dos laminados cerâmicos ultrafinos quando o teste estático foi utilizado. Entretanto, o modo de falha foi significativamente diferente, sendo que a porcelana sofreu mais lascamentos do que o dissilicato de lítio; o qual, por sua vez, apresentou a maioria das falhas relacionadas à estrutura dental. (2) Não foi possível determinar uma combinação de parâmetros de ciclagem mecânica que permitisse a determinação dos parâmetros de fadiga para laminados cerâmicos ultrafinos, já que o número máximo de ciclos alcançados foi de 536.818 ciclos. Dessa forma, estudos futuros precisam ser realizados para que uma metodologia apropriada permita determinar parâmetros de fadiga clinicamente relevantes para laminados cerâmicos ultrafinos em dentes anteriores. / Objectives: (1) to determine the fracture load and the failure mode of the ultra-thin ceramic laminates processed via CAD-CAM according to the microstructure of the material (lithium disilicate-based glass-ceramic or leucite-based porcelain); (2) to develop a fatigue methodology capable of determining the lifetime of ultra-thin ceramic laminates processed via CAD-CAM. Materials and methods: sixteen human maxillary central incisors were used to produce the specimens. The teeth required minimal preparation on the enamel for proper adaptation of the ultra-thin ceramic laminates. Ceramic laminates made of lithium disilicate and feldspathic porcelain with thicknesses between 0.3 mm to 0.5 mm were produced via CAD-CAM and cemented with resin cement. Four specimens of each group were taken to a universal testing machine to determine the fracture load of the laminates. For the development of a fatigue methodology, a series of pilot tests was performed using different parameters such as: type of antagonist (natural teeth or metal roller), applied load (20, 30 or 40 N), and type of masticatory cycle (incision or sliding). Failure modes were analysed using a stereomicroscope. Fracture load data were analysed by ANOVA and Tukey\'s test. Results: the mean fracture load obtained for the glass-ceramic was 431.8 ± 217.9 N, while that obtained for the porcelain was 454.4 ± 72.1 N. There was no statistical difference between the mean fracture load values; however, the standard deviation and the coefficient of the variation of the glass-ceramic were both higher than those obtained for the porcelain. There was also a difference in the failure modes for the two materials tested. The porcelain showed a higher number of factures due to chipping and the lithium disilicate showed a higher number of tooth structure failure. The fatigue experiment showed different results depending on the condition analysed. In the incision cycle, the antagonists (natural tooth) fractured when loads of 30 N and 40 N were applied. In the slide type of cycle, the antagonist (natural tooth) suffered wear on the incisal edge after applying 30 N of load. For the metal roller antagonist, when a 30 N load was applied, the ceramic laminate fractured, and when a 20 N load was applied, an excessive wear of the metal roller occurred. Conclusion: (1) The material used did not affect the fracture load of ultra-thin ceramic laminates when the static test was used. However, the failure mode was significantly different, as porcelain suffered more chipping than the lithium disilicate; which, in turn, showed most fails related to the tooth structure. (2) It was not possible to determine the combination of the mechanical cycling parameters that would allow the determination of fatigue parameters for ultra-thin ceramic laminates, since the maximum number of cycles reached was 536,818 cycles. In this way, future studies need to be carried out so that a clinically relevant methodology can be developed to determine the fatigue parameters of ultra-thin ceramic laminates in the anterior teeth.