Spelling suggestions: "subject:"condição""
321 |
Comparação das medidas de pressão não invasivas pelos metodos do Doppler e Pos-capilar em membros inferiores : estudo realizado em individuos sem obstruções arteriaisMenezes, Fábio Hüsemann, 1962- 18 July 2018 (has links)
Orientador : João Poterio Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-18T07:25:20Z (GMT). No. of bitstreams: 1
Menezes_FabioHusemann_M.pdf: 1388418 bytes, checksum: 62556d72f442c7749bb42113b9309b88 (MD5)
Previous issue date: 1993 / Resumo: Desenvolveu-se este estudo para comparar, em membros inferiores, o método Pós-capilar para medida não-invasiva de pressão arterial com o método do Doppler. Foram estudados dois grupos de indivíduos que não apresentavam diferença estatística em relação a sexo, idade e presença de fatores de risco para arteriosclerose: 36 pacientes diabéticos e 37 voluntários sem diabetes mellitus, todos com pulsos presentes nos pés. Mostrou-se que o método Pós-capilar tem correlação com o método do Doppler, mas hipoestima as pressões nos indivíduos com índice pressórico tornozelo/braço (pelo método do Doppler) menor ou igual a 1,2. Nos indivíduos com índice tornozelo/braço (pelo método do Doppler) elevado, o método Pós-capilar estima nos pés pressões mais próximas das pressões dos membros superiores. Conclue-se que o método Pós-capilar não se aplica como substituto ao método do Doppler para a medida de pressão em indivíduos sem endurecimento arterial, mas está indicado nos casos com artérias endurecidas e, especialmente, quando as artérias são incompressíveis, o que torna não confiável a leitura da pressão com o método do Doppler / Abstract: The purpose of this study was to compare the non invasive blood pressure determination techniques of the Doppler and Post-capillary, used for the lower limbs. Two groups of subjects were studied. There was no statistical difference between the groups in regard to sex, age and risk factors for atherosclerosis. The first group consisted of 36 patients with Diabetes Mellitus, and the second group of 37 volunteers with no history of Diabetes. All subjects had palpable pulses at the foot. There could be demonstrated that the Post-capillary technique correlated well with the Doppler in those subjects with a Doppler ankle/brachial index lower or equal to 1. 2, even though the new technique underestimated the pressure in this group. In those subjects with stiffened arteries, with a Doppler ankle/brachial index higher than 1.2, the Post-capillary technique estimated pressure values closer to the arm pressure values. We conclude that the Post-capillary technique can not be used as a substitute for the Doppler technique in those subjects with palpable pulses and without stiffened arteries. Nonetheless i t is indicated for the evaluation of those subjects with stiffened arteries, and it's best indication is for those subjects with calcified arteries, where the Doppler derived pressures can not be trusted / Mestrado / Cirurgia / Mestre em Cirurgia
|
322 |
Anteprojeto de um sistema de medição para hidrometros eletronicosOliveira, Marcia Reis de 20 December 1990 (has links)
Orientador: Jose Antonio Siqueira Dias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T04:22:27Z (GMT). No. of bitstreams: 1
Oliveira_MarciaReisde_M.pdf: 2129641 bytes, checksum: 6a8eedb986d6e28ade0e11be4d66a9e9 (MD5)
Previous issue date: 1990 / Resumo: Este trabalho refere-se ao anteprojeto de um sistema de medição para hidrômetros eletrônicos, cujo objetivo foi de se obter uma maior confiabilidade, além de uma maior precisão nos sistemas atualmente em uso pela SABESP.Foi desenvolvido o projeto de um circuito integrado contendo uma parte analógica (bipolar) e uma parte digital (em tecnologia I2L). Estes circuitos operam com 3 volts de alimentação e consomem 15uApermitindo uma duração de 3,0 a 3,5 anos às baterias de alimentação do circuito. Foi também desenvolvido um sensor eletromagnético e um sistema de interface para saída de dados para uma leitora externa / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
|
323 |
Uma abordagem para avaliação de desempenho de processos de negócios baseada em modelos pré-definidosSILVA, Thiago Rodrigo Mendes da 07 August 2015 (has links)
Submitted by Bárbara Carmo (barbara.queirozcarmo@ufpe.br) on 2018-11-23T21:47:21Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Thiago Rodrigo Mendes da Silva.pdf: 2886233 bytes, checksum: 8cc2a4ba35de7f4fe200d796a8bd687e (MD5) / Rejected by Alice Araujo (alice.caraujo@ufpe.br), reason: on 2018-11-23T21:48:30Z (GMT) / Submitted by Bárbara Carmo (barbara.queirozcarmo@ufpe.br) on 2018-11-23T21:53:07Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Thiago Rodrigo Mendes da Silva.pdf: 2886233 bytes, checksum: 8cc2a4ba35de7f4fe200d796a8bd687e (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-23T22:00:32Z (GMT) No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Thiago Rodrigo Mendes da Silva.pdf: 2886233 bytes, checksum: 8cc2a4ba35de7f4fe200d796a8bd687e (MD5) / Made available in DSpace on 2018-11-23T22:00:32Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Thiago Rodrigo Mendes da Silva.pdf: 2886233 bytes, checksum: 8cc2a4ba35de7f4fe200d796a8bd687e (MD5)
Previous issue date: 2015-08-07 / A Gestão de Processos de Negócio (em inglês, Business Process Management ou BPM) é uma abordagem sistemática que possibilita identificar, desenhar, executar, documentar, medir, monitorar e controlar os processos de negócios, visando tornar a organização capaz de alcançar resultados consistentes e alinhados com seus objetivos estratégicos. Nesse contexto, as organizações necessitam realizar a medição do desempenho dos seus processos, permitindo apoiar o planejamento, induzindo o controle e possibilitando um diagnóstico da situação atual em relação à consecução dos objetivos estabelecidos. A proposta deste trabalho é motivada pela baixa investigação empírica das medidas de desempenho propostas na literatura e pelas dificuldades das organizações em verificar os resultados dos seus processos de negócios. Esta pesquisa tem como objetivo principal investigar e analisar os modelos pré-definidos ou abordagens para avaliação de desempenho de processos de negócios que permitem uma melhor visualização quanto ao alinhamento dos resultados do processo com os objetivos estratégicos. Para isto, foi realizada uma Revisão Sistemática da Literatura (RSL) a fim de coletar dados de estudos primários relacionados à avaliação de desempenho de processos de negócios. A partir dos resultados encontrados, ficou evidente que, dentre as abordagens analisadas, existem diversas variações na metodologia, nas especificações das medidas e até mesmo quanto à forma como os processos de negócio são avaliados. Com base na avaliação comparativa entre as abordagens, foi definido um conjunto de critérios que abordam tanto a teoria, fundamentada nas referências selecionadas, como em alguns aspectos de usabilidade de um modelo de desempenho de processo. Dessa forma, foi possível propor a definição de uma nova abordagem que reúne elementos e recomendações selecionados a partir das abordagens analisadas, acrescidos de melhorias que facilitam o seu uso. Para avaliar a abordagem proposta, um estudo de caso é discutido, apresentando resultados importantes que mostram a sua aplicabilidade. Como principal limitação, deve-se observar que a aplicação e avaliação de um único caso não permite que os resultados sejam generalizados para todas as organizações e contextos. Como conclusão, deve-se ressaltar que esta dissertação contribui com a proposta de uma abordagem que apresenta importantes elementos para avaliação de desempenho de processos de negócios nas organizações. Por fim, é importante ressaltar que, a abordagem não compreende um conjunto de procedimentos rígidos, mas passíveis de adaptação de acordo com os processos de negócios e objetivos da organização. / Business Process Management (English Business Process Management or BPM) is a systematica approach to business that enables the identification, design, execution, documentation, measurement, monitoring and control of business process in order to enable the organization to achieve consistent results aligned with its strategic objectives. Organizations need to measure the performance of their processes to support the planning, directing and controlling a diagnosis effort of challenging situations in relation to achieving the set goals. The purpose of this work is motivated by the low presence of empirical investigation of performance measures in the literature and the difficulties of organizations to check the results of their business processes. This research work aims to investigate and analyze models or approaches for assessing the performance of business process to enable a better view of the results of the process with the strategic objectives. A Systematic Literature Review (SLR) was held to collect data from primary studies related to the evaluation of business process performance. From the results of the review, it became clear that among the analyzed approaches, there are several variations in the methodology, the specifications of measures and even in how business processes are evaluated. Based on the comparative evaluation of the approaches, it was defined a set of criteria that adresses the theory, based on the selected references, and some usability aspects of a process performance model. The results made it possible to propose the definition of a new approach that brings together selected elements anda recommendations from the analyzed approaches, plus improvements that facilitate their use. To evaluate the proposed approach, a case study is discussed, presenting importante results showing its applicability. It should be noted as major limitation that the implementation and evaluation of a single case does not allow results to be generalized to all organizations and contexts. In conclusion, this dissertation contributes to proposed approach that presents important elements for assessing the performance of business process in organizations. It is important to emphasize that the approach does not comprise a set of strict procedures, but subjects to changes according to the business process and goals of the organization.
|
324 |
Metrologia em química : validação do método analítico e estimativa da incerteza da medição para pH de etanol combustível (pHe) /Villa de Paula, Paulo Ricardo. January 2014 (has links)
Orientador: Fernando Luis Fertonani / Banca: Lídia Maria de Almeida Plicas / Banca: José Ricardo Turquetti / Resumo: O etanol é uma matriz energética que requere como especificação da qualidade a medição do parâmetro pH. A formação de recursos humanos, RH, com conhecimento metrológico em química, capaz de gerar e interpretar resultados provenientes da medição desse parâmetro e outros importantes do ponto de vista do rigor metrologia deve fazê-lo com ciência, consciência e pertinência de seu trabalho (BIÈVRE et al, 2010; GAUSTER, 1991; VALCÁRCEL, 2000). O presente trabalho utilizou de normas reguladoras para a medição do parâmetro supracitado a fim de obter a estimativa da incerteza das medidas de pHe. Também foram desenvolvidos procedimentos para a validação do método analítico de medição de pHe bem como a formação de RH devidamente treinado no sistema da qualidade para atuar no bojo das normas ABNT NBR 10891:2013 e ASTM D6423:2008. Também foi propósito deste estudo conhecer as minúcias da medição de pH em meio etanólico. O treinamento em medição de pH e rigor metrológico foi realizado em meio aquoso. No tocante a norma ABNT NBR 10891:2006 e desenvolvimento do trabalho foram coletadas três amostras de etanol combustível de postos de combustíveis distintos em que os valores obtidos estavam em conformidades com aqueles preconizados pela resolução ANP N°7:2011 isto é, 6,0 < pHe < 8,0. Para a estimativa da incerteza da medição de pHe o procedimento de validação contou com quatro parâmetros de performance, a linearidade, sensibilidade, precisão e exatidão. Os resultados obtidos da validação foram satisfatórios tornando evidente a adequação do método ao ensaio proposto. O estudo da incerteza padrão combinada demonstrou que a maior fonte de incerteza é aquela associada a repetibilidade, sendo passível de ser minimizada aplicando-se programas de treinamento técnico de pessoal, evidenciando assim a importância da adoção da metrologia no rol de disciplinas obrigatórias nos cursos da área de exatas / Abstract: Anhydrous ethanol and fuel are arrays that require energy as quality specification of the pH measurement parameter, which is set to the aqueous medium. The formation of human, HR resources, with metrological knowledge in chemistry, able to generate and interpret data from the measurement of this parameter and other important from the point of view of accuracy metrology must do so with knowledge, awareness and relevance of their work (Bievre et al, 2010; Gauster, 1991; VALCÁRCEL, 2000). This work included the study of regulatory standards for the measurement of the above parameters in order to obtain the estimated uncertainty of the measurements of pHe. Procedures for the validation of the analytical method for measuring pHe well as the formation of HR trained in the quality system to operate in the core of ABNT NBR 10891:2013 and ASTM D6423: 2008. Purpose of this study was also to know the minutiae of measuring pH in ethanol medium. The training metrological accuracy and pH monitoring was carried out in an aqueous medium. Regarding the ABNT NBR 10891:2006 and development work three samples of different ethanol fuel stations in the values obtained were in conformity with those recommended by ANP Resolution No. 7:2011 fuel between 6.0 < pHe <8.0. To estimate the uncertainty of measurement of pHe validation procedure had four performance parameters, linearity, sensitivity, precision and accuracy. The results of the validation were satisfactory pointing to the adequacy of the proposed test method. The combined standard uncertainty of the study showed that the largest source of uncertainty is that associated with repeatability, being able to be minimized by applying technical personnel training programs, thus underlining the importance of the adoption of metrology in the list of compulsory subjects in courses the exact sciences / Mestre
|
325 |
Concentrações de espécies químicas no curso de água após eventos de precipitação obtidas por monitoramento de alta frequênciaGirardi, Rubia, 1982-, Pinheiro, Adilson, 1961-, Garbossa, Luis Hamilton Pospissil, 1977-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2016 (has links) (PDF)
Orientador: Adilson Pinheiro. / Co-orientador: Luis Hamilton Pospissil Garbossa. / Dissertação (Mestrado em Engenharia Ambiental) - Programa de Pós-Graduação em Engenharia Ambiental, Centro de Ciências Tecnológicas, Universidade Regional de Blumenau, Blumenau.
|
326 |
Validação de métodos para as técnicas de WDXRF e OES -spark, na análise de aços. Cálculo de incerteza de medição para amostras de processo, aço classe API / VALIDATION OF METHODS FOR WDXRF AND OES-SPARK TECHNIQUES IN STEEL ANALYSIS. DETERMINATION OF THE UNCERTAINTY OF MEASUREMENTS FOR API STEEL PLANT SAMPLECarlos Eduardo da Silva 18 February 2009 (has links)
Em conseqüência do aumento da demanda de gás e petróleo no mercado nacional e internacional, as especificações e certificações dos resultados de analises químicas de tubos para gasodutos e oleodutos têm se tornados cada vez mais exigentes. Um contínuo desenvolvimento tem sido realizado para a melhoria de aços microligados da classe API (American Petroleum Institute). As propriedades do aço dependem do controle da composição química e parâmetros de processo durante sua fabricação. Neste trabalho, foi realizada comparação das incertezas de medição entre as técnicas de espectrometria de fluorescência de raios X por comprimento de onda (WDXRF) e de emissão óptica com fonte de arco voltaico (OES-spark) nas análises de acompanhamento de processo na produção de aços classe API. Usualmente, este tipo de análise requer menos de 40 segundos para completa caracterização química para ajuste nos parâmetros de processo de produção. As principais fontes de influência nas análises químicas foram avaliadas por planejamento de experimentos. Os elementos constituintes e traço como Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo e Sn foram determinados utilizando as metodologias normalizadas pela ASTM E-322, E-415, E-1009 e E-1085. Os materiais de referência certificados 185A e 187A da CMI (Czech Metrology Institute) foram utilizados para avaliação dos métodos. As incertezas das medições de resultados e a validação com relação a repetitividade e reprodutibilidade das medições foram obtidas conforme os testes estatísticos, recomendados pela norma ISO/IEC 17025. A incerteza de medição para cada elemento é discutida para ambas as técnicas. / The increase of gas and petroleum demanding in the national and international markets, the specification and certification of the chemical analysis results of gas and oil pipe-line have became more and more challenging. A continuous development has been outlined to improve API grade alloy steels (American Petroleum Institute). The steel properties depend on the chemical composition control and process parameters during its manufacturing. In this work, a comparison of the measurement uncertainty between X-ray fluorescence (WD system) and Optical Emission (OES-spark) spectrometries, for API grade steel plant samples analysis, was outlined. Usually, this kind of analyze requires less than 40 seconds for full chemical characterization for adjustment in the process parameters production. The main influence source in the chemical analysis was evaluated for design of experiments. The constituents and trace elements such as Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo and Sn were determined using the ASTM E-322, E-415, E-1009 and E-1085 standard methodologies. The 185A and 187A certified reference materials from CMI (Czech Metrology Institute) were used for evaluation of the methods. The uncertainty of the measurement, precision, accuracy, repeatability and reproducibility of the measurements were obtained applying statistic tests, recommended by ISO/IEC 17025. The uncertainty of measurement for each element is discussed for both techniques.
|
327 |
Calibração absoluta de goniômetro e polígonos ópticos.Jackeline Carla Seixas de Lima Pinto 13 November 2009 (has links)
A calibração de artefatos angulares como os polígonos ópticos e de instrumentos como goniômetros é um problema constantemente discutido e avaliado nos Laboratórios Nacionais de Metrologia; e para isso são necessários alguns procedimentos antes de qualquer calibração como, por exemplo, a escolha correta do tipo de equipamento a ser utilizado e saber como utilizar os métodos de avaliação de incerteza. Um método de calibração absoluta apresenta dificuldades quando não se dispõe de um padrão, o que permitiria uma fácil avaliação dos resultados obtidos. Daí a busca por diferentes métodos neste trabalho, para avaliar a compatibilidade dos resultados. Neste trabalho, utilizamos um goniômetro e dois polígonos óticos de 18 faces com diferentes tamanhos e duas técnicas de calibração (NIST e Roseta/IPT) para que possamos ao final do processo ter os polígonos e o goniômetro calibrados ao mesmo tempo. Foi também realizado o desenvolvimento de um polígono manufaturado no IEAv, para disponibilizar um artefato produzido a baixo custo, que viabilizasse futuras intercomparações. Sua fabricação apresentou obstáculos intransponíveis no momento, mas permitiram expor o artefato aos métodos utilizados, mesmo fora das especificações. Os resultados finais obtidos mostraram boa concordância, mesmo para o polígono manufaturado no IEAv, considerando-se que ele estava muito fora da especificação angular.
|
328 |
Avaliação metrológica de um sistema de calibração de acelerômetros por choque mecânicoAilson Nogueira Campos 28 December 2010 (has links)
Este trabalho apresenta a operacionalização e a análise metrológica de um sistema de calibração de acelerômetros por choque mecânico. O referido sistema é composto por um conjunto de aplicação de choque por queda livre, um analisador de sinais dinâmicos, um par de condicionadores e um acelerômetro piezoelétrico padrão de referência. A operacionalização consistiu em elaborar um procedimento de medição e desenvolver um software de aquisição e análise de resultados, já a avaliação metrológica, buscou comparar a exatidão do sistema através de especificações técnicas dos equipamentos utilizados, as recomendações previstas em norma e de avaliações experimentais, objetivando identificar e avaliar as principais componentes de incertezas que influenciam nos resultados de calibração. A técnica estudada complementa a técnica atualmente muito empregada na calibração de acelerômetros, atingindo valores de amplitude até 200 vezes maior e com incertezas na ordem de 3 a 5 % do valor da sensibilidade de choque medida.
|
329 |
Proposta de um modelo de previsão do estado de carga de baterias chumbo-ácidoMiguel Igino Valentini 30 September 2014 (has links)
O trabalho apresenta uma proposta de estudo de um modelo estatístico capaz de prever, a partir de valores extraídos de uma rápida medição de impedância, o estado de carga de uma bateria chumbo-ácido. Os dados foram levantados em um experimento que contou com dez medições de impedância em uma bateria nova nos estados de carga de 100% a 10%, sendo as medições realizadas através do método da espectroscopia de impedância eletroquímica (EIE). As curvas características, resultantes das medições, foram ajustadas com o auxílio de um circuito elétrico equivalente, tal qual fora proposto por Randles em 1947. Os dados foram linearizados e uma tabela de correlação foi estruturada para a definição das variáveis independentes que melhor explicam a relação entre o estado de carga e a alteração de parâmetros internos da bateria. Ferramentas estatísticas, como regressão linear e teste de hipóteses, foram utilizadas para elaboração do modelo de previsão que consta de três variáveis independentes, uma relacionada à resistência pura, devido principalmente à formação do sulfato de chumbo nas placas e a combinação das resistências ôhmicas nas conexões, nos separadores das placas e no eletrólito, outra devido à variação da capacitância da dupla camada e a terceira que é função da difusão de íons no eletrólito. Os resultados mostraram-se satisfatórios, considerando o caso específico da bateria utilizada nos testes, os objetivos propostos foram atingidos, podendo ser utilizados como base para trabalhos futuros, como a associação da previsão do estado de carga ao estado de saúde da bateria, o desenvolvimento de equipamentos de medição da impedância mais baratos e modelos de previsão que possam compensar as variações de temperatura nos ambientes de medição.
|
330 |
Validação de métodos para as técnicas de WDXRF e OES -spark, na análise de aços. Cálculo de incerteza de medição para amostras de processo, aço classe API / VALIDATION OF METHODS FOR WDXRF AND OES-SPARK TECHNIQUES IN STEEL ANALYSIS. DETERMINATION OF THE UNCERTAINTY OF MEASUREMENTS FOR API STEEL PLANT SAMPLESilva, Carlos Eduardo da 18 February 2009 (has links)
Em conseqüência do aumento da demanda de gás e petróleo no mercado nacional e internacional, as especificações e certificações dos resultados de analises químicas de tubos para gasodutos e oleodutos têm se tornados cada vez mais exigentes. Um contínuo desenvolvimento tem sido realizado para a melhoria de aços microligados da classe API (American Petroleum Institute). As propriedades do aço dependem do controle da composição química e parâmetros de processo durante sua fabricação. Neste trabalho, foi realizada comparação das incertezas de medição entre as técnicas de espectrometria de fluorescência de raios X por comprimento de onda (WDXRF) e de emissão óptica com fonte de arco voltaico (OES-spark) nas análises de acompanhamento de processo na produção de aços classe API. Usualmente, este tipo de análise requer menos de 40 segundos para completa caracterização química para ajuste nos parâmetros de processo de produção. As principais fontes de influência nas análises químicas foram avaliadas por planejamento de experimentos. Os elementos constituintes e traço como Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo e Sn foram determinados utilizando as metodologias normalizadas pela ASTM E-322, E-415, E-1009 e E-1085. Os materiais de referência certificados 185A e 187A da CMI (Czech Metrology Institute) foram utilizados para avaliação dos métodos. As incertezas das medições de resultados e a validação com relação a repetitividade e reprodutibilidade das medições foram obtidas conforme os testes estatísticos, recomendados pela norma ISO/IEC 17025. A incerteza de medição para cada elemento é discutida para ambas as técnicas. / The increase of gas and petroleum demanding in the national and international markets, the specification and certification of the chemical analysis results of gas and oil pipe-line have became more and more challenging. A continuous development has been outlined to improve API grade alloy steels (American Petroleum Institute). The steel properties depend on the chemical composition control and process parameters during its manufacturing. In this work, a comparison of the measurement uncertainty between X-ray fluorescence (WD system) and Optical Emission (OES-spark) spectrometries, for API grade steel plant samples analysis, was outlined. Usually, this kind of analyze requires less than 40 seconds for full chemical characterization for adjustment in the process parameters production. The main influence source in the chemical analysis was evaluated for design of experiments. The constituents and trace elements such as Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo and Sn were determined using the ASTM E-322, E-415, E-1009 and E-1085 standard methodologies. The 185A and 187A certified reference materials from CMI (Czech Metrology Institute) were used for evaluation of the methods. The uncertainty of the measurement, precision, accuracy, repeatability and reproducibility of the measurements were obtained applying statistic tests, recommended by ISO/IEC 17025. The uncertainty of measurement for each element is discussed for both techniques.
|
Page generated in 0.1013 seconds