• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 2
  • 2
  • 1
  • Tagged with
  • 86
  • 46
  • 29
  • 27
  • 26
  • 25
  • 20
  • 15
  • 14
  • 12
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de cicatrização em pele de dorso de ratos induzida pela resina acrílica quimicamente ativada e desenvolvimento de gel acrílico

Jucá Rêgo Lima Netto, Osman 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T16:26:36Z (GMT). No. of bitstreams: 2 arquivo2156_1.pdf: 1712852 bytes, checksum: 3850b32a1588491d5215dcf34a37eb8e (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / A Todo instante nosso corpo está sujeito a lesões e muitas são as substâncias e técnicas no sentido de prover o mais rápido restabelecimento da região. Alguns polímeros desempenham interferência proativa na cicatrização, destacando-se colágeno, fibrina, quitosana, cianoacrilatos, num grupo chamado de cola biológica. Extratos naturais de plantas também concorrem em volume de estudos, ao auxílio da regeneração tecidual. Cicatrizes fibrosadas (quelóides), em regiões que comprometem a estética, levam seus portadores a um decréscimo de auto-estima. Portanto o controle de infecções, manutenção do sistema imunológico e reparação tecidual organizada, constituem-se relevantes eventos para boa cicatrização. O polímero PMMA (polimetilmetacrilato de metila) é bastante utilizado na indústria de forma geral, na medicina, na odontologia, nos implantes, na liberação de fármacos. Sua familiaridade ao cianoacrilato, notabilizado na síntese de tecidos, seu uso no preenchimento de sulcos e rugas faciais, a estimulação do sistema imune e adesividade, sinalizam-no como agente cicatrizante. Testou-se propositivamente, seu comportamento em feridas em dorso de ratos. Na primeira etapa do trabalho, obteve-se feridas através de um punch cirúrgico com 0,8 cm. Sobre as mesmas colocou-se em aplicação única PMMA (G3) quimicamente ativado em pó e líquido, analisados nos tempos T7, T15 e T21 dias. Nesses períodos os animais foram sacrificados igualmente àqueles tratados com solução salina(G1) e por sutura (G2-Fio seda 000 Ethicon®), n=6. Peças histológicas foram retiradas, fixadas em solução tampão de formol a 10%, recebendo tratamento rotineiro para microscopia óptica. Os preparos corados em HE-Hematoxilina Eosina e Tricrômio de Masson, objetivou analisar as estruturas gerais, células de defesa, fibroblásticas, vasos, colágeno e epitélio. A captura de imagens das lâminas realizou-se através de microscópio óptico, acoplado ao sistema ATI tv Player Versão 6.3. Contou-se colágeno analiticamente pelo sistema Imagelab Versão 2.4, enquanto que os demais parâmetros, pelo ImageJ. Demonstrou-se aumento do número de células de defesa no grupo tratado com PMMA em T7 e redução em T21, quando comparado aos demais grupos, enquanto que o número de células fibroblásticas manteve-se superior em todos os tempos analisados, finalizando em T21 com maior nível de colágeno e similaridade na espessura de epitélio. Concluído o primeiro estudo, seguiu-se desenvolvimento galênico e respectivos controles de géis de PMMA. Nesse segundo estudo, provocou-se duas feridas de 0,6cm de diâmetro nos dorsos de 30 animais, uma próxima à cervical, e outra distante 2 cm. Comparou-se histlogicamente em 3 períodos, T5, T14 e T20 dias, o gel PMMA (SG4) ao gel PMMA+ aroeira (SG3), aos controles Salina (SG1) e Fibrase®(SG2), todos com aplicação diária, n=5. Os resultados mostraram maior número de células de defesa e fibroblástica em SG4/ T5 e T14, enquanto que a espessura do epitélio em T5 foi substancialmente maior nos SG 3 e 4, concordando com a planimetria observada com paquímetro digital®. Concluiu-se que a ocorrência do maior número de células de defesa nos primeiros dias nos grupos tratados com PMMA levou a um processo cicatricial mais rápido e equilibrado, destacando que após o sétimo dia de tratamento, um organismo saudável, equilibra os fenômenos hemodinâmicos
2

Análise da incorporação de nanopartículas de prata a uma resina acrílica para base protética /

Monteiro, Douglas Roberto. January 2009 (has links)
Orientador: Débora Barros Barbosa / Banca: Wirley Gonçalves Assunção / Banca: Emerson Rodrigues de Camargo / Resumo: O objetivo do presente estudo foi avaliar a incorporação de nanopartículas de prata a uma resina acrílica para base protética por meio de testes de liberação em água deionizada por diferentes períodos e através de análises da distribuição e dispersão destas partículas na massa polimérica. Utilizou-se a resina acrílica termopolimerizável Lucitone 550 e as nanopartículas de prata foram sintetizadas por meio da redução dos íons prata do nitrato de prata pelo citrato de sódio. A forma e o tamanho das partículas foram confirmados por microscopia eletrônica de varredura (MEV) e de transmissão (MET), tendo-se obtido partículas na forma esférica e com tamanho médio de 60 nm. A resina acrílica foi proporcionada de acordo com as instruções do fabricante e a solução coloidal de nanopartículas de prata foi adicionada ao componente líquido da resina acrílica nas concentrações de 0,05%, 0,5% e 5% baseadas na massa do polímero. Após o processamento laboratorial, os espécimes foram armazenados em água deionizada à 37ºC por 7, 15, 30, 60 e 120 dias. As amostras de cada solução foram analisadas por espectroscopia de absorção atômica. Espécimes antes e após 120 dias de imersão em água foram analisados por MEV para caracterização morfológica do nanocompósito. Não houve liberação de prata detectável pelo aparelho, independentemente da concentração de colóide adicionada ao polímero e do tempo de imersão em água deionizada. As microscopias mostraram que, de uma forma geral, quanto menor a concentração de colóide de prata adicionada, menor a distribuição e maior a dipersão das partículas no polímero. Também ocorreu uma tendência das nanopartículas localizarem-se, principalmente, na superfície externa dos espécimes após 120 dias de armazenamento. Concluiu-se que houve incorporação das nanopartículas de prata ao polímero da resina... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the incorporation of silver nanoparticles to an acrylic denture base resin by testing the silver release in deionized water at different times, and through morphological analysis to check the distribution and dispersion of these particles in the polymer. The heat-polymerised acrylic resin Lucitone 550 was used and the silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The form and size of the particles were confirmed by scanning and transmission electron microscopy. Most of the particles showed a diameter of about 60 nm and spherical form. The acrylic resin was prepared in accordance with the manufacturers' instructions and silver nanoparticles solution was added to the monomer of the acrylic resin in the concentrations of 0.05wt%, 0.5wt% and 5wt%. The specimens were stored in deionized water at 37ºC for 7, 15, 30, 60 and 120 days, and each solution was analyzed by atomic absorption spectroscopic. The specimens were characterized by scanning electron microscopy before and after their immersion in water. Silver was not detected in deionized water regardless of the silver nanoparticles added to the polymer and of the storage period. The micrographs usually showed that when lower concentrations of silver nanoparticles were added, the particles distribution was reduced whereas their dipersion was improved into the polymer. Moreover, nanoparticles were mainly located at the surface of the specimens after 120 days of storage. The results showed that the silver nanoparticles were incorporated in the denture base resin polymer, and these nanoparticles were not detected in deionized water for up to 120 days. Moreover, the distribution and dispersion of the particles in the polymer changed with the silver concentration added and the period of storage. / Mestre
3

Estudo da degradação causada por íons, elétrons e fótons energéticos em poli (metacrilato de metila) (PMMA)

Schappo, Marcelo Girardi January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Física, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:10:05Z (GMT). No. of bitstreams: 1 340730.pdf: 11693559 bytes, checksum: 4ada99a71eb6b414c8b093494f7251ef (MD5) Previous issue date: 2016 / Quando radiação ionizante incide na matéria, ela pode produzir diversos efeitos diferentes, dependendo do tipo de radiação e do tipo de alvo. Alguns desses fenômenos são a dessorção e desbaste (arrancando material da superfície e ejetando da amostra), degradação química (quebra de ligações químicas do material) e também essas ligações quebradas podem desencadear processos de formação de novas moléculas. Todas essas consequências levam a alterações nas propriedades químicas, físicas e organolépticas, que são de interesse industrial, científico e tecnológico. O material de interesse analisado é o PMMA ? Poli(metacrilato de metila), polímero de monômero com massa 100u, cujo interesse de aplicação vai desde superfície exposta em satélites até como máscara para litografia em microeletrônica. As radiações ionizantes utilizadas foram ultravioleta, íons energéticos (feixes de prótons H+ de 600keV e 1,5MeV, feixe de hélio He+ de 1,0MeV e feixe de nitrogênio N2+ de 1,5MeV) e elétrons (energia 3,0keV), visando investigar diferentes condições de degradação do polímero, que foram analisadas com diferentes técnicas experimentais: espectrometria de massa de íons secundários por tempo-de-voo (ToF/SIMS) e por quadrupolo em gás residual (QMS/RGA), que permitem identificar os espécimes químicos emitidos da amostra enquanto irradiada ou após irradiação, espectroscopia de fluorescência no ultravioleta, permitindo identificar a existência de luminescência na amostra e a eventual mudança dessa propriedade após diferentes doses de radiação recebidas, e espectroscopia de absorção no infravermelho (FTIR), que identifica as bandas de absorção de diferentes ligações químicas no material de interesse e como essas bandas se modificam após doses de radiação ionizantes. Nos dados específicos com FTIR, foi calculada a seção de choque de quebra de ligação para o PMMA, um dado importante que se relaciona com o tempo de durabilidade do material exposto à radiação. Os resultados obtidos mostram um comportamento de dupla queda exponencial nos gráficos de razão de áreas nos picos do infravermelho em função da dose de íons e elétrons, sendo o feixe de N2+ o responsável pela maior degradação do material. Foi detectado ausência de luminescência no PMMA, mas mudança na refletividade do mesmo após diferentes doses de irradiação com elétrons. Além disso, o efeito de irradiação com luz UV também gera quebra do polímero em fragmentos, e essas mudanças foram detectadas com espectrometria de massa por tempo de voo e por quadrupolo. As instituições envolvidas no trabalho são a Universidade Federal de Santa Catarina (UFSC), a Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio), o Laboratório Nacional de Luz Síncrotron (LNLS) e o Instituto Federal de Educação, Ciência e Tecnologia de Santa Catarina (IFSC).<br> / Abstract: Interaction between ionizing radiation and matter can lead to several effects, which depends on kind of radiation and target. Sputtering, desorption, chemical degradation are such examples of phenomena involved. Hence, analysis of material changes under incident radiation is interest issue of science, technology and industry. In this work, PMMA polymer - poly(methyl methacrylate) is subjected to the following radiations: ultraviolet, ion beams (protons H+ 600keV and 1,5MeV, helium He+ 1,0MeV and nitrogen N2+ 1,5MeV) and electrons (3,0keV). Its applications vary from exposed surfaces on sattelites devices to lithography resist, booth into irradiation conditions. Polymer degradation analysis was performed with different experimental techniques: Time-of-Flight Secondary Ion Mass Spectrometry (ToF/SIMS) and Quadrupole Mass Spectrometry on Residual Gas Analyzer (QMS/RGA) to measure material fragments ejected from surface after radiations doses, Fluorescence Spectroscopy on Visible and Ultraviolet Wavelenghts to investigate this behavior on PMMA and Fourier Transform Infrared Spectroscopy (FTIR), which allow to determine the chemical bonds concentration changes inside material after irradiations. The chemical bonds breaking cross section was calculated from FTIR data, and it is an important experimental result because is related to the durability time of PMMA under technological uses. The results show no luminescence behavior on PMMA, but reflectiveness changes after electron irradiation. Mass distribution on ToF spectrum also changes after UV irradiation, and FTIR data lead to double exponencial decay behavior for chemical bonds degradation with ion beam and electron doses. Institutions involved on this work: Santa Catarina Federal University (UFSC), Rio de Janeiro Catholical University (PUC-Rio), Brazilian Synchrotron Light Laboratory (CNPEM-LNLS) and Santa Catarina Federal Institute of Education, Science and Technology (IFSC).
4

Adição de nanopartículas de prata ao Poli (metil metacrilato) : análise microbiológica /

Takamiya, Aline Satie. January 2010 (has links)
Orientador: Débora Barros Barbosa / Banca: Wirley Gonçalves Assunção / Banca: Cristiane Yumi Koga Ito / Resumo: O objetivo do presente estudo foi verificar a atividade antimicrobiana de uma resina acrílica à base de poli (metil metacrilato) (PMMA) contendo nanopartículas de prata frente ao microorganismo Candida albicans. Utilizou-se a resina acrílica termopolimerizável Lucitone 550 e as nanopartículas de prata foram sintetizadas por meio da redução dos íons prata do nitrato de prata pelo citrato de sódio. A forma e o tamanho das partículas foram confirmados por microscopia eletrônica de varredura (MEV) e de transmissão (MET), tendo-se obtido partículas na forma esférica e com tamanhos médios de 5 e 10 nm. A resina acrílica foi proporcionada de acordo com as instruções do fabricante e a solução coloidal de nanopartículas de prata foi adicionada ao componente líquido da resina acrílica nas concentrações de 0,05%, 0,5% e 5% baseadas na massa do polímero. Após o processamento, os espécimes foram esterilizados por radiação de Co-60. Foram analisados a adesão de microorganismos à superfície do poli (metil metacrilato)/prata (PMMA/Ag) e a formação de biofilme por Candida albicans sobre a superfície polimérica através de microscopia de luz e de MEV. Os resultados mostraram redução estatisticamente significante (P < 0,05) da adesão de microorganismos à superfície do nanocompósito para os grupos com 0,05 e 0,5% de nanopartículas de prata com tamanho de 5nm quando comparados ao grupo controle. A microscopia de luz nãomostrou diferença na formação de biofilme entre os grupos dos nanocompósitos e o grupo controle. A MEV sugeriu uma redução na quantidade de células na superfície dos grupos contendo nanopartículas de prata, especialmente até 12 horas de crescimento fúngico. Os resultados sugerem ação inibitória sobre a adesão e formação de biofilme por Candida albicans quando da adição de nanopartículas de prata de tamanho 5 nm à resina acrílica nas concentrações de 0,05% e 0,5% / Abstract: The aim of this study was to verify the antimicrobial activity of a poly (methyl methacrylate) acrylic resin containing silver nanoparticles against Candida albicans microorganism. The heat-polymerized acrylic resin Lucitone 550 was used and the silver nanoparticles were synthesized through the reduction of silver ions of silver nitrate by sodium citrate. The shape and size of the particles were confirmed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and showed spherical particles with medium size of 5 and 10 nm. The acrylic resin was proportioned according to the manufacturer's instructions and the silver nanoparticles colloid solution was added to the liquid of the acrylic resin in 0.05%, 0.5% and 5% of concentration based on the polymer mass. After being processing, the specimens were sterilized by Co-60 radiation. The adhesion of cells of Candida albicans and the biofilm formation on the surface of the polymer were evaluated by light microscopy and SEM. The results demonstrated significantly reduction (P < .05) of the microorganisms adhesion on the surface of the nanocomposites for the groups containing 0.05 and 0.5% of silver nanoparticles with size of 5nm when compared to the control group. The light microscopy did not show difference in the biofilm formation among the groups evaluated. The SEM images suggested reduction of growth of Candida albicans cells for the nanocomposite groups, mainly up to the period of 12 hours. It was concluded that the addition of silver nanoparticles with size of 5 nm to the PMMA in 0.05% and 0.5% concentrations showed antimicrobial effect against Candida albicans / Mestre
5

Estudo da adição de lama de bauxita em polímero de poli(metacrilato de metila) por meio de polimerização em massa e moldagem em casting / STUDY OF RED MUD ADDITION IN THE POLI (METHYL METACRYLATE) BY MASS POLIMERIZATION AND CASTING PROCESS MOLDING

Wander Burielo de Souza 29 May 2008 (has links)
O trabalho refere-se ao desenvolvimento de formulações de poli (metacrilato de metila) (PMMA) contendo lama de bauxita proveniente de processo Bayer. A adesão entre a lama de bauxita e o poli (metacrilato de metila) ocorreu em todas as concentrações testadas (10-70%), mostrando o aumento progressivo das propriedades mecânicas de resistência à tração, resistência à flexão e módulo de elasticidade na tração como na flexão. As propriedades mecânicas são compatíveis com as diversas finalidades de emprego de superfícies sólidas. A estabilidade térmica do composto de poli (metacrilato de metila) com alto nível de lama de bauxita (70%) é semelhante a do material padrão estudado. Os estudos de citoxidade revelam que superfícies sólidas obtidas a partir de lama vermelha não possuem toxidade nas condições testadas. / The work refers to the development of formulations of poly (methyl metacrylate) (PMMA) and red mud from Bayer process. The adhesion between PMMA and the filler was achieved in the experimental concentration range (10-70%), showing progressive increase of mechanical properties as flexion resistance and modulus. Other mechanical properties are compatible with service life of solid surfaces. The results of thermal stability indicated that formulation with red mud high content (70%) are similar to the standart. Citotoxicity tests revealed no toxicity of the materials in the test conditions.
6

Estudo da adição de lama de bauxita em polímero de poli(metacrilato de metila) por meio de polimerização em massa e moldagem em casting / STUDY OF RED MUD ADDITION IN THE POLI (METHYL METACRYLATE) BY MASS POLIMERIZATION AND CASTING PROCESS MOLDING

Souza, Wander Burielo de 29 May 2008 (has links)
O trabalho refere-se ao desenvolvimento de formulações de poli (metacrilato de metila) (PMMA) contendo lama de bauxita proveniente de processo Bayer. A adesão entre a lama de bauxita e o poli (metacrilato de metila) ocorreu em todas as concentrações testadas (10-70%), mostrando o aumento progressivo das propriedades mecânicas de resistência à tração, resistência à flexão e módulo de elasticidade na tração como na flexão. As propriedades mecânicas são compatíveis com as diversas finalidades de emprego de superfícies sólidas. A estabilidade térmica do composto de poli (metacrilato de metila) com alto nível de lama de bauxita (70%) é semelhante a do material padrão estudado. Os estudos de citoxidade revelam que superfícies sólidas obtidas a partir de lama vermelha não possuem toxidade nas condições testadas. / The work refers to the development of formulations of poly (methyl metacrylate) (PMMA) and red mud from Bayer process. The adhesion between PMMA and the filler was achieved in the experimental concentration range (10-70%), showing progressive increase of mechanical properties as flexion resistance and modulus. Other mechanical properties are compatible with service life of solid surfaces. The results of thermal stability indicated that formulation with red mud high content (70%) are similar to the standart. Citotoxicity tests revealed no toxicity of the materials in the test conditions.
7

Modificação química de amostras de poli(metacrilato de metila) comerciais com aminas funcionalizadas assistidas por micro-ondas / Chemical modification of commercial poly(methyl methacrylate) with functionalized amines assisted by microwave

Bianca da Rocha Mandarino 28 February 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho avaliou a reação de amidação sob catálise de DBU/NaCN de amostras comerciais de poli(metacrilato de metila), (PMMA), massa molar 60.000 u.m.a. com as aminas, alilamina, 2-morfolilaminoetano, 1-(3-aminopropil)-imidazol e N,N-dimetil-trimetilenodiamina com ativação por reator de micro-ondas. O estudo com alilamina e 2-morfolilaminoetano se mostrou eficaz, apresentando percentuais de derivatização significativos (27% e 37% , respectivamente). A quantidade de material polimérico obtido na purificação foi de cerca de 36 % para as duas aminas. O estudo evidenciou a importância dos catalisadores DBU/NaCN, pois sem eles a reação não ocorre e quando utilizados isoladamente, o grau de incorporação é muito menor. Já o estudo com as aminas 1-(3-aminopropil)-imidazol e N,N-dimetil-trimetilenodiamina mostrou-se ineficaz devido à dificuldade de purificação dos produtos. Tentativas de purificação por precipitação com metanol e soluções hidrometanólicas de diferentes concentrações mostraram-se ineficazes. Os novos PMMA modificados foram caracterizados por FT-IR, RMN-1H e análise elementar. Foram observadas alterações na taticidade do PMMA em reações ativadas por micro-ondas / This study evaluated the reaction of amidation under catalysis of DBU / NaCN of commercial samples of poly(methylmethacrylate) (PMMA) with a molecular weight 60,000 with the amines, allylamine, 2-morfollylaminoethane, 1-(3-aminopropyl)-imidazole and N,N-dimethyl-trimethylendiamine under microwave irradiation. The reaction allylamine and 2-morfolilaminoetano was observed with a significant percentage of derivatization. In addition, this study also showed the importance of the use of catalytic DBU / NaCN, without them the reaction does not occur and if used alone, the level of incorporation is much smaller. The study with amines 1-(3-aminopropyl)-imidazole and N, N-dimethyl-trimethylenediamine was inconclusive due to the difficulties in purifying the products. Attempts purification by precipitation with methanol and hidrometanólicas solutions of different concentrations have proven ineffective. The new modified PMMA were characterized by FT-IR, 1H-NMR and elemental analysis. There were changes on the tacticity in PMMA reactions activated by microwave
8

Modificação química de amostras de poli(metacrilato de metila) comerciais com aminas funcionalizadas assistidas por micro-ondas / Chemical modification of commercial poly(methyl methacrylate) with functionalized amines assisted by microwave

Bianca da Rocha Mandarino 28 February 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho avaliou a reação de amidação sob catálise de DBU/NaCN de amostras comerciais de poli(metacrilato de metila), (PMMA), massa molar 60.000 u.m.a. com as aminas, alilamina, 2-morfolilaminoetano, 1-(3-aminopropil)-imidazol e N,N-dimetil-trimetilenodiamina com ativação por reator de micro-ondas. O estudo com alilamina e 2-morfolilaminoetano se mostrou eficaz, apresentando percentuais de derivatização significativos (27% e 37% , respectivamente). A quantidade de material polimérico obtido na purificação foi de cerca de 36 % para as duas aminas. O estudo evidenciou a importância dos catalisadores DBU/NaCN, pois sem eles a reação não ocorre e quando utilizados isoladamente, o grau de incorporação é muito menor. Já o estudo com as aminas 1-(3-aminopropil)-imidazol e N,N-dimetil-trimetilenodiamina mostrou-se ineficaz devido à dificuldade de purificação dos produtos. Tentativas de purificação por precipitação com metanol e soluções hidrometanólicas de diferentes concentrações mostraram-se ineficazes. Os novos PMMA modificados foram caracterizados por FT-IR, RMN-1H e análise elementar. Foram observadas alterações na taticidade do PMMA em reações ativadas por micro-ondas / This study evaluated the reaction of amidation under catalysis of DBU / NaCN of commercial samples of poly(methylmethacrylate) (PMMA) with a molecular weight 60,000 with the amines, allylamine, 2-morfollylaminoethane, 1-(3-aminopropyl)-imidazole and N,N-dimethyl-trimethylendiamine under microwave irradiation. The reaction allylamine and 2-morfolilaminoetano was observed with a significant percentage of derivatization. In addition, this study also showed the importance of the use of catalytic DBU / NaCN, without them the reaction does not occur and if used alone, the level of incorporation is much smaller. The study with amines 1-(3-aminopropyl)-imidazole and N, N-dimethyl-trimethylenediamine was inconclusive due to the difficulties in purifying the products. Attempts purification by precipitation with methanol and hidrometanólicas solutions of different concentrations have proven ineffective. The new modified PMMA were characterized by FT-IR, 1H-NMR and elemental analysis. There were changes on the tacticity in PMMA reactions activated by microwave
9

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas metalicas implantossuportadas / Influence of vennering material and spark erosion on marginal misfit of implant-suported frameworks

Oliveira, Luciana Valadares 26 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:25:40Z (GMT). No. of bitstreams: 1 Oliveira_LucianaValadares_D.pdf: 36824583 bytes, checksum: 7a4d2a0d063c3cd9180327ea1a830f60 (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação dos revestimentos estéticos sobre infraestruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Este trabalho avaliou o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da porcelana e da eletroerosão sobre o desajuste de infra-estruturas implantossuportadas. Foi utilizada uma matriz metálica simulando um arco mandibular, contendo 5 pilares intermediários do tipo Microunit (Conexão Sistema de Próteses, Brasil). Sobre essa matriz, foram enceradas 40 infra-estruturas, fundidas em liga de CoCr (Remanium 2000, Alemanha). Para cada infra-estrutura, foi confeccionado um index, parafusando-se 5 réplicas em cada uma das infra-estruturas. Esse conjunto foi posicionado em gesso pedra especial com auxílio de delineador, antes da aplicação dos revestimentos estéticos, para avaliar o desajuste provocado apenas pela fase de aplicação dos revestimentos estéticos e ciclo de cocção da porcelana. As infra-estruturas foram separadas aleatoriamente: G1: resina acrílica termopolimerizável (Clássico, Clássico, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: porcelana (Carmen, Dentaurum, Alemanha); G4: simulação dos ciclos de cocção da porcelana. Antes da aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index, após aperto de 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido no outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador (STN ¿ Olympus Optical, Japão). Procedeu-se o processo de eletroerosão (Tel Med Technologies, EUA), e novamente avaliação do desajuste marginal. Os resultados obtidos foram submetidos à Análise de Variância e teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 56,97 µm (± 16,86); G2: 43,27 µm (± 16,49); G3: 49,26 µm (± 17,11); G4: 40,66 µm (+ 10,85). A aplicação dos revestimentos estéticos e simulação dos ciclos de cocção da porcelana aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 170,01 µm (±53,98); G2: 72,32 µm (±27,49); G3: 164,84 µm (±27,67); e G4: 86,28 µm (±20,01). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após eletroerosão, as médias de desajuste marginal apresentaram valores significamente menores para os grupos: Gl: 108, 54 µm (±40,75); G3: 109,61 µm (±24,42); e G4: 59,63 µm (±22,13). A média de desajuste marginal para o grupo de resina fotopolimerizável não apresentou diferença estatística significante: G2: 49,70 µm (±16,65). Como observado anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença dos grupos G2 e G4. Conclui-se que os revestimentos estéticos em resina acrílica e porcelana produzem os maiores valores de desajuste marginal para próteses implantossuportadas, enquanto a resina fotopolimerizável, os menores. A aplicação de porcelana resultou em maiores valores de desajuste marginal que apenas a simulação dos ciclos de cocção. A eletroerosão foi eficaz na redução dos desajustes marginais até os limites considerados clinicamente aceitáveis / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Co-Cr (Remanium 2000, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Carmen, Dentaurum, Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 56.97(± 16.86); G2: 43.27(± 16.49); G3: 49.26(± 17.11); G4: 40.66(± 10.85). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 170.01 µm (±53.98); G2: 72.32 µm (+±27.49); G3: 164.84 µm (±27.67); e G4: 86.28 µm (±20.01). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean values decreased significantly for the following groups: G1: 108. 54 µm (±40.75); G3: 109.61 µm (±24.42); and G4: 59.63 µm (±22.13). The light curing group decreased the marginal gap mean values, but not significantly after the spark erosion procedure: G2: 49.70 µm (±16.65). As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles only. The spark erosion procedure was efficacious in reducing the frameworks marginal gaps to the levels clinically accepted for all groups evaluated. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
10

Análise da incorporação de nanopartículas de prata a uma resina acrílica para base protética

Monteiro, Douglas Roberto [UNESP] 02 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-02Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1 monteiro_dr_me_araca.pdf: 1306834 bytes, checksum: 0b13167dddf5ad2f97a668d7bc126eab (MD5) / O objetivo do presente estudo foi avaliar a incorporação de nanopartículas de prata a uma resina acrílica para base protética por meio de testes de liberação em água deionizada por diferentes períodos e através de análises da distribuição e dispersão destas partículas na massa polimérica. Utilizou-se a resina acrílica termopolimerizável Lucitone 550 e as nanopartículas de prata foram sintetizadas por meio da redução dos íons prata do nitrato de prata pelo citrato de sódio. A forma e o tamanho das partículas foram confirmados por microscopia eletrônica de varredura (MEV) e de transmissão (MET), tendo-se obtido partículas na forma esférica e com tamanho médio de 60 nm. A resina acrílica foi proporcionada de acordo com as instruções do fabricante e a solução coloidal de nanopartículas de prata foi adicionada ao componente líquido da resina acrílica nas concentrações de 0,05%, 0,5% e 5% baseadas na massa do polímero. Após o processamento laboratorial, os espécimes foram armazenados em água deionizada à 37ºC por 7, 15, 30, 60 e 120 dias. As amostras de cada solução foram analisadas por espectroscopia de absorção atômica. Espécimes antes e após 120 dias de imersão em água foram analisados por MEV para caracterização morfológica do nanocompósito. Não houve liberação de prata detectável pelo aparelho, independentemente da concentração de colóide adicionada ao polímero e do tempo de imersão em água deionizada. As microscopias mostraram que, de uma forma geral, quanto menor a concentração de colóide de prata adicionada, menor a distribuição e maior a dipersão das partículas no polímero. Também ocorreu uma tendência das nanopartículas localizarem-se, principalmente, na superfície externa dos espécimes após 120 dias de armazenamento. Concluiu-se que houve incorporação das nanopartículas de prata ao polímero da resina... / The aim of this study was to evaluate the incorporation of silver nanoparticles to an acrylic denture base resin by testing the silver release in deionized water at different times, and through morphological analysis to check the distribution and dispersion of these particles in the polymer. The heat-polymerised acrylic resin Lucitone 550 was used and the silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The form and size of the particles were confirmed by scanning and transmission electron microscopy. Most of the particles showed a diameter of about 60 nm and spherical form. The acrylic resin was prepared in accordance with the manufacturers’ instructions and silver nanoparticles solution was added to the monomer of the acrylic resin in the concentrations of 0.05wt%, 0.5wt% and 5wt%. The specimens were stored in deionized water at 37ºC for 7, 15, 30, 60 and 120 days, and each solution was analyzed by atomic absorption spectroscopic. The specimens were characterized by scanning electron microscopy before and after their immersion in water. Silver was not detected in deionized water regardless of the silver nanoparticles added to the polymer and of the storage period. The micrographs usually showed that when lower concentrations of silver nanoparticles were added, the particles distribution was reduced whereas their dipersion was improved into the polymer. Moreover, nanoparticles were mainly located at the surface of the specimens after 120 days of storage. The results showed that the silver nanoparticles were incorporated in the denture base resin polymer, and these nanoparticles were not detected in deionized water for up to 120 days. Moreover, the distribution and dispersion of the particles in the polymer changed with the silver concentration added and the period of storage.

Page generated in 0.065 seconds