• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 27
  • 27
  • 11
  • 11
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Classification System for the Spread of Polymethyl Methacrylate in Vertebral Bodies Treated with Vertebral Augmentation

Frankl, Joseph, Sakata, Michael P., Choudhary, Gagandeep, Hur, Seung, Peterson, Andrew, Hennemeyer, Charles T. 09 1900 (has links)
In this study, we develop a classification system for describing polymethyl methacrylate (PMMA) spread in vertebral bodies after kyphoplasty or vertebroplasty for vertebral compression fractures (VCFs) and for assessing whether PMMA spread varies between operators, VCF etiology, or vertebral level. Intraoperative fluoroscopic images of 198 vertebral levels were reviewed in 137 patients (women, 84; men, 53; mean age, 75.8 +/- 12.5; and those with a diagnosis of osteoporosis, 63%) treated with kyphoplasty between January 01, 2015 and May 31, 2015 at a single center to create a 5-class descriptive system. PMMA spread patterns in the same images were then classified by 2 board-certified radiologists, and a third board-certified radiologist resolved conflicts. A total of 2 primary PMMA spread patterns were identified, namely, acinar and globular, with subtypes of localized acinar, diffuse globular, and mixed, to describe an equal combination of patterns. Interrater reliability using the system was moderate (kappa = 0.47). After resolving conflicts, the most common spread class was globular (n = 63), followed by mixed (n = 58), diffuse globular (n = 30), acinar (n = 27), and localized acinar (n = 20). The spread class after treatment by the 2 most frequent operators differed significantly (n(1) = 63, n(2) = 70; P <.0001). There was no difference in the spread class between VCF etiologies or vertebral levels. PMMA spread may, therefore, be a modifiable parameter that affects kyphoplasty and vertebroplasty efficacy and adverse events.
2

Avaliação in vitro da citotoxicidade de resinas acrílicas para reembasamento baseadas em uma nova formulação

Costa, Cristiane Campos [UNESP] 19 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-19Bitstream added on 2014-06-13T20:58:45Z : No. of bitstreams: 1 costa_cc_me_arafo.pdf: 3083928 bytes, checksum: 2605dd91339dbf0d4e3c26e02afc6696 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi determinar a citotoxicidade in vitro de duas resinas reembasadoras experimentais autopolimerizáveis contendo alta concentração de agentes de ligação cruzada, etilenoglicol dimetacrilato (EGDMA) e 1,4-butanodiol dimetacrilato (BDMA) comparadas com uma resina reembasadora comercial (Tokuyama Rebase Fast II). Foram confeccionados corpos-de-prova em forma de discos das três resinas acrílicas reembasadoras rígidas sob condições assépticas. Os fibroblastos (L929) foram cultivados em placas com 96 compartimentos e incubadas por 24 h em meio de cultura Eagle. Os extratos foram preparados, colocando-se três amostras de cada resina em frascos de vidro estéreis com 9 mL de meio de Eagle e incubadas a 37º C por 24 h. O efeito citotóxico dos extratos foram avaliados utilizando os testes de incorporação do 3H-timidina e MTT, que refletem os níveis de síntese de DNA e metabolismo celular, respectivamente. Os dados foram analisados estatisticamente, utilizando análise de variância (P<0.05). Para o teste de incorporação do 3H-timidina, não foram observadas diferenças significativas (P>0.05) entre os materiais. A média da quantidade do isótopo incorporado no DNA celular para todas as resinas acrílicas foi estatisticamente menor do que para o controle. Todas as resinas acrílicas foram classificadas pelo teste de incorporação do 3Htimidina como moderadamente citotóxicas. Da mesma forma, para o teste do MTT, não foi encontrada diferença significativa para a citotoxicidade entre os materiais (P>0.05). Quando a citotoxidade foi comparado com o grupo controle, todas as resinas foram classificadas entre não citotóxicas e discretamente citotóxicas pelo teste do MTT. Assim, conclui-se que a incorporação dos agentes de ligação cruzada, EGDMA e BDMA não influenciaram significativamente sobre a citotoxicidade observada. Não houve diferença... / The aim of this study was to determine the cytotoxicity in vitro of two trials autopolymerizing reline systems made with higher concentration of cross-linking agents, EGDMA and BDMA compared to a commercial reline resin. Sample disks of the three hard reline acrylic resins were fabricated under aseptic conditions. The Fibroblast L929 cells were cultured in 96-well plates and incubated for 24 h in Eagle's medium. Eluates were prepared by placing three samples into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37ºC for 24 h. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. The data were statistically analyzed by using the one-way analysis of variance (P<.05). With the 3H-thymidine incorporation assay, no significant differences (P > .05) were found between the materials. The mean quantity of isotope incorporated into cellular DNA for all acrylic resins was statistically smaller than for the control. All acrylic resins were graded by the 3Hthymidine incorporation assay as moderate cytotoxic. Similarly, with the MTT assay, no significant difference in cytotoxicity was found between the materials (P > .05). When the cytotoxicity was compared with control group, all resins assay were between non cytotoxic and slight cytotoxic by the MTT. The incorporation of cross-linking agents, EGDMA and BDMA had no significant influence on the cytotoxicity observed. There was no cell viability difference between all materials in both assays.
3

Adição de nanopartículas de prata ao Poli (metil metacrilato): análise microbiológica

Takamiya, Aline Satie [UNESP] 08 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-08Bitstream added on 2014-06-13T19:37:36Z : No. of bitstreams: 1 takamiya_as_me_araca.pdf: 2744019 bytes, checksum: 436939ec1fb2e59f419b688a517c064c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi verificar a atividade antimicrobiana de uma resina acrílica à base de poli (metil metacrilato) (PMMA) contendo nanopartículas de prata frente ao microorganismo Candida albicans. Utilizou-se a resina acrílica termopolimerizável Lucitone 550 e as nanopartículas de prata foram sintetizadas por meio da redução dos íons prata do nitrato de prata pelo citrato de sódio. A forma e o tamanho das partículas foram confirmados por microscopia eletrônica de varredura (MEV) e de transmissão (MET), tendo-se obtido partículas na forma esférica e com tamanhos médios de 5 e 10 nm. A resina acrílica foi proporcionada de acordo com as instruções do fabricante e a solução coloidal de nanopartículas de prata foi adicionada ao componente líquido da resina acrílica nas concentrações de 0,05%, 0,5% e 5% baseadas na massa do polímero. Após o processamento, os espécimes foram esterilizados por radiação de Co-60. Foram analisados a adesão de microorganismos à superfície do poli (metil metacrilato)/prata (PMMA/Ag) e a formação de biofilme por Candida albicans sobre a superfície polimérica através de microscopia de luz e de MEV. Os resultados mostraram redução estatisticamente significante (P < 0,05) da adesão de microorganismos à superfície do nanocompósito para os grupos com 0,05 e 0,5% de nanopartículas de prata com tamanho de 5nm quando comparados ao grupo controle. A microscopia de luz nãomostrou diferença na formação de biofilme entre os grupos dos nanocompósitos e o grupo controle. A MEV sugeriu uma redução na quantidade de células na superfície dos grupos contendo nanopartículas de prata, especialmente até 12 horas de crescimento fúngico. Os resultados sugerem ação inibitória sobre a adesão e formação de biofilme por Candida albicans quando da adição de nanopartículas de prata de tamanho 5 nm à resina acrílica nas concentrações de 0,05% e 0,5% / The aim of this study was to verify the antimicrobial activity of a poly (methyl methacrylate) acrylic resin containing silver nanoparticles against Candida albicans microorganism. The heat-polymerized acrylic resin Lucitone 550 was used and the silver nanoparticles were synthesized through the reduction of silver ions of silver nitrate by sodium citrate. The shape and size of the particles were confirmed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and showed spherical particles with medium size of 5 and 10 nm. The acrylic resin was proportioned according to the manufacturer’s instructions and the silver nanoparticles colloid solution was added to the liquid of the acrylic resin in 0.05%, 0.5% and 5% of concentration based on the polymer mass. After being processing, the specimens were sterilized by Co-60 radiation. The adhesion of cells of Candida albicans and the biofilm formation on the surface of the polymer were evaluated by light microscopy and SEM. The results demonstrated significantly reduction (P < .05) of the microorganisms adhesion on the surface of the nanocomposites for the groups containing 0.05 and 0.5% of silver nanoparticles with size of 5nm when compared to the control group. The light microscopy did not show difference in the biofilm formation among the groups evaluated. The SEM images suggested reduction of growth of Candida albicans cells for the nanocomposite groups, mainly up to the period of 12 hours. It was concluded that the addition of silver nanoparticles with size of 5 nm to the PMMA in 0.05% and 0.5% concentrations showed antimicrobial effect against Candida albicans
4

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas metalicas implantossuportadas / Influence of vennering material and spark erosion on marginal misfit of implant-suported frameworks

Oliveira, Luciana Valadares 26 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:25:40Z (GMT). No. of bitstreams: 1 Oliveira_LucianaValadares_D.pdf: 36824583 bytes, checksum: 7a4d2a0d063c3cd9180327ea1a830f60 (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação dos revestimentos estéticos sobre infraestruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Este trabalho avaliou o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da porcelana e da eletroerosão sobre o desajuste de infra-estruturas implantossuportadas. Foi utilizada uma matriz metálica simulando um arco mandibular, contendo 5 pilares intermediários do tipo Microunit (Conexão Sistema de Próteses, Brasil). Sobre essa matriz, foram enceradas 40 infra-estruturas, fundidas em liga de CoCr (Remanium 2000, Alemanha). Para cada infra-estrutura, foi confeccionado um index, parafusando-se 5 réplicas em cada uma das infra-estruturas. Esse conjunto foi posicionado em gesso pedra especial com auxílio de delineador, antes da aplicação dos revestimentos estéticos, para avaliar o desajuste provocado apenas pela fase de aplicação dos revestimentos estéticos e ciclo de cocção da porcelana. As infra-estruturas foram separadas aleatoriamente: G1: resina acrílica termopolimerizável (Clássico, Clássico, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: porcelana (Carmen, Dentaurum, Alemanha); G4: simulação dos ciclos de cocção da porcelana. Antes da aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index, após aperto de 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido no outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador (STN ¿ Olympus Optical, Japão). Procedeu-se o processo de eletroerosão (Tel Med Technologies, EUA), e novamente avaliação do desajuste marginal. Os resultados obtidos foram submetidos à Análise de Variância e teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 56,97 µm (± 16,86); G2: 43,27 µm (± 16,49); G3: 49,26 µm (± 17,11); G4: 40,66 µm (+ 10,85). A aplicação dos revestimentos estéticos e simulação dos ciclos de cocção da porcelana aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 170,01 µm (±53,98); G2: 72,32 µm (±27,49); G3: 164,84 µm (±27,67); e G4: 86,28 µm (±20,01). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após eletroerosão, as médias de desajuste marginal apresentaram valores significamente menores para os grupos: Gl: 108, 54 µm (±40,75); G3: 109,61 µm (±24,42); e G4: 59,63 µm (±22,13). A média de desajuste marginal para o grupo de resina fotopolimerizável não apresentou diferença estatística significante: G2: 49,70 µm (±16,65). Como observado anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença dos grupos G2 e G4. Conclui-se que os revestimentos estéticos em resina acrílica e porcelana produzem os maiores valores de desajuste marginal para próteses implantossuportadas, enquanto a resina fotopolimerizável, os menores. A aplicação de porcelana resultou em maiores valores de desajuste marginal que apenas a simulação dos ciclos de cocção. A eletroerosão foi eficaz na redução dos desajustes marginais até os limites considerados clinicamente aceitáveis / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Co-Cr (Remanium 2000, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Carmen, Dentaurum, Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 56.97(± 16.86); G2: 43.27(± 16.49); G3: 49.26(± 17.11); G4: 40.66(± 10.85). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 170.01 µm (±53.98); G2: 72.32 µm (+±27.49); G3: 164.84 µm (±27.67); e G4: 86.28 µm (±20.01). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean values decreased significantly for the following groups: G1: 108. 54 µm (±40.75); G3: 109.61 µm (±24.42); and G4: 59.63 µm (±22.13). The light curing group decreased the marginal gap mean values, but not significantly after the spark erosion procedure: G2: 49.70 µm (±16.65). As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles only. The spark erosion procedure was efficacious in reducing the frameworks marginal gaps to the levels clinically accepted for all groups evaluated. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
5

Influencia da adição de politetrafluoretileno (PTFE) nas propriedades fisicas, mecanicas e aderencia microbiana em resinas acrilicas / Influence of polytetrafluorethylene (PTFE) added to acrylic resin on its physical and mechanical properties and microorganism adherence on acrylic resin

Straioto, Fabiana Gouveia 15 August 2018 (has links)
Orientadores: Altair Antoninha Del Bel Cury, Alfredo Julio Fernandes Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T07:28:18Z (GMT). No. of bitstreams: 1 Straioto_FabianaGouveia_D.pdf: 1136819 bytes, checksum: 94255ae316940aec09bc64b1ad3b35c2 (MD5) Previous issue date: 2010 / Resumo: Resinas acrílicas são materiais amplamente empregados na Odontologia, especialmente os polímeros a base de polimetilmetacrilato (PMMA) para confecção de próteses. Dentre as vantagens deste material estão à estabilidade de cor, propriedades ópticas, estética satisfatória, estabilidade dimensional, fácil manipulação e propriedades físicas adequadas para aplicações odontológicas. Entretanto, como desvantagem deste material, está à susceptibilidade à aderência e desenvolvimento de biofilme por microrganismos presentes na cavidade bucal, como fungos e bactérias. A aderência de microrganismo é o primeiro evento para o desenvolvimento do biofilme o qual está relacionado ao estabelecimento de quadros clínicos patológicos como estomatite protética. Recentemente, a adição de modificadores na composição da resina acrílica tem sido proposta com o objetivo de melhorar as características de superfície, e conseqüentemente controlar a aderência de microrganismos. Entretanto, a mudança na composição da resina acrílica não deverá comprometer as propriedades físicas. Politetrafluoretileno (PTFE) tem sido usado como modificador para confecção de stents e cateteres devido a biocompatibilidade, alta resistência a agentes químicos e baixa energia de superfície. Assim, o objetivo neste estudo foi avaliar as propriedades físicas, características de superfície, aderência de microrganismos e formação de biofilme de suas resinas acrílicas, uma polimerizada em água quente com ciclo longo e a outra polimerizada pelo ciclo curto, contendo 2% de PTFE em sua composição e comparar com as mesmas resinas sem adição de PTFE. Para isto, três estudos foram realizados: 1- Propriedades físicas da resina acrílica - espécimes das resinas foram confeccionados de acordo com a norma ISO 1567:1999 (n=10) para cada teste mecânico: dureza de superfície, resistência ao impacto, resistência a flexão e o módulo de elasticidade e carga máxima foram calculados; 2 - Características de superfície da resina acrílica e aderência de Candida albicans: espécimes retangulares (n=10) para cada resina foram confeccionados e avaliados quanto à rugosidade, ângulo de contato, energia livre de superfície e aderência de Candida albicans. As células aderidas foram expressas por unidade formadora de colônia por área da superfície; 3- Biofilme formado na resina acrílica e sua composição: discos de resina acrílica (n=6) foram usados para formação de biofilme de Streptococcus mutans UA159, Streptococcus sanguinis ATCC 10556 e Actinomyces naeslundii ATCC 12104. A composição de polissacarídeos e unidades formadoras de colônia foram comparadas. Em todos os estudos, os resultados foram submetidos à análise variância a dois fatores e comparados pelo teste de Tukey (p=0,05). Os resultados não mostraram diferença estatisticamente significante para os valores de dureza de superfície (p>0,05). Entretanto, para os valores de resistência ao impacto e flexão para os grupos experimentais, contendo PTFE, apresentaram resultados significantemente menores (p<0,05) quando comparados aos grupos não adicionados de PTFE. Os valores de módulo de elasticidade da resina acrílica adicionada com 2% de PTFE polimerizada com o ciclo longo apresentaram os maiores valores comparados aos demais grupos (p<0,05). Não houve diferenças significativas para rugosidade, ângulo de contato e energia livre de superfície (p>0,05); houve uma tendência de redução de células de C. albicans no grupo com PTFE, mas não foi estatisticamente significante. Em relação, a formação e composição de polissacarídeo os resultados não apresentaram diferenças entre os grupos de resina acrílica (p>0,05). Os resultados sugerem que 2% de PTFE adicionada à resina acrílica não foi suficiente para promover mudanças nas propriedades mecânicas, aderência e composição do biofilme. / Abstract: Acrylic resins have been widely used in Dentistry, especially polymers of poly (methyl methacrylate) for fabricating dentures. This material has as advantages stable color and optical properties, satisfactory esthetic and dimensional stability, it is easy to be processed, and its physical properties have been proven adequate for dental applications. However, as disadvantage acrylic resins surface is susceptible to adherence and biofilm development of oral microorganism, such as fungi and bacteria. Microorganism's adherence is the first step to biofilm development, and it is related to pathogenic condition, leading to denture stomatitis. Recently, it had been proposed addition of modifiers to acrylic resin composition that could be able to improve its surface properties, and consequently controlling microorganisms' adherence. However, this change in composition of acrylic resin should not compromise its physical properties. Polytetrafluorethylene has been used as modifiers to fabricate medical devices such as stents and catheters because it is a biocompatible material, high resistance to chemical reagents and low surface energy. Thus, the aim of this study was to evaluate the physical properties, surface characteristics, adherence of microorganisms and biofilm formation of two acrylic resins, one polymerized by long and other polymerized by short cycle, with 2% (w/w) of PTFE added and to compare with the same resins with no PTFE added. For this, three studies were conducted: 1 - Physical properties of acrylic resins - specimens were prepared for each acrylic resin according to the ISO standard 1567:1999 (n=10) for each mechanical test: surface hardness, impact strength, flexural strength and flexural modulus and peak load were calculated; 2 - Characteristics of acrylic resin surface and adherence of Candida albicans: rectangular specimens (n=10) of each resin were prepared and evaluated for surface roughness, contact angle, surface free energy and C.albicans adherence. Adhered cells were expressed in colony forming units per surface area; 3- Biofilm formed on acrylic resins and its composition: acrylic resin discs (n=6) were used to Streptococcus mutans UA 159, Streptococcus sanguinis ATCC 10556 and Actinomyces naeslundii ATCC 12104 biofilm formation. Polysaccharide composition and colony forming units were compared. For both three studies the results of were analyzed by Two-Way ANOVA and Tukey test (P<.05). The results showed no statistical significant differences for surface hardness (P>0.05). However, impact and flexural strengths values for experimental groups, with PTFE added were significantly lower (P<.05) when compared to the groups with no PTFE added. The flexural modulus values of acrylic resin containing 2% PTFE polymerized by long cycle was higher than other resins (P<0.05). No statistical differences were found for roughness, contact angle, surface free energy (P>.05); there was a reduction trend in C. albicans adherence in acrylic resin with PTFE added, but it was not statistically significant. Regarding, the formation and composition of polysaccharide matrix the results showed no differences among the acrylic resin groups (P>0.05). The results showed that the 2% of PTFEE incorporated to acrylic resins was not enough to affect the mechanical properties, adherence and composition of biofilm. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
6

Development of Candida albicans biofilms in the presence of fluconazole = effects on extracellular matrix = Desenvolvimento de biofilmes de Candida albicans na presença de fluconazol : efeitos na matriz extracelular / Desenvolvimento de biofilmes de Candida albicans na presença de fluconazol : efeitos na matriz extracelular

Gonçalves, Letícia Machado, 1987- 27 September 2013 (has links)
Orientador: Wander José da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T13:26:50Z (GMT). No. of bitstreams: 1 Goncalves_LeticiaMachado_D.pdf: 3139804 bytes, checksum: 4f3ad00e23ae5ec0336267a151dbe2e0 (MD5) Previous issue date: 2012 / Resumo: O fluconazol (FLZ) é um antifúngico amplamente utilizado no tratamento da candidose associada ao uso de prótese dental. No entanto, o sucesso desta terapia pode ser dificultado pela presença da matriz extracelular dos biofilmes de Candida albicans. Estudos já foram conduzidos avaliando o efeito do FLZ em biofilmes de C. albicans, no entanto, estudos que simulem uma condição na qual os biofilmes são desenvolvidos na presença do FLZ são escassos. Ainda, na tentativa de avaliar a organização tridimensional destes biofilmes, várias técnicas de microscopia já foram descritas, apesar de pouca atenção ser dada na análise da matriz extracelular. Frente ao exposto, o objetivo deste trabalho foi avaliar a matriz extracelular de biofilmes de C. albicans na presença de concentração salivar de FLZ. Dois estudos foram conduzidos e, em ambos, discos (10 mm x 2 mm) de resina acrílica à base de poli (metil metacrilato) foram confeccionados e cobertos com uma película de saliva sobre a qual biofilmes de C. albicans foram desenvolvidos. O primeiro estudo foi conduzido com o objetivo de definir uma metodologia para análise da matriz extracelular. Biofilmes de C. albicans ATCC 90028 foram desenvolvidos em meio de cultura sem suplementação (controle) ou suplementado com glicose ou sacarose, por 72 horas. Durante o desenvolvimento dos biofilmes foi adicionado o corante Concanavalina A (ConA) para a marcação da matriz extracelular. Após o desenvolvimento, os biofilmes foram corados com SYTO 9 para a marcação das células. As imagens obtidas por microscopia confocal foram analisadas pelo software COMSTAT. Para confirmação dos resultados, os biofilmes foram coletados e analisados bioquimicamente para determinação da composição da matriz de polissacarídeos pelo método fenol-sulfúrico. Os dados foram analisados por ANOVA seguido do teste de Tukey com nível de significância de 5%. Para o segundo estudo, biofilmes de C. albicans (ATCC 90028) e de dois isolados clínicos (P01 e P34) foram desenvolvidos em meio de cultura contendo FLZ na concentração biodisponível na saliva (2,56 ?g/mL), durante 48h. O grupo controle foi desenvolvido sem a presença de fluconazol. O número de células viáveis foi quantificado por diluição seriada, e a matriz extracelular analisada bioquimicamente, além da avaliação por microscopia confocal. Os dados foram analisados pelo teste t de Student com nível de significância de 5%. No primeiro estudo, observou-se que o uso de ConA permitiu uma marcação eficaz da matriz extracelular, confirmada pela análise bioquímica (p < 0,05). No segundo estudo, houve uma redução de 80% no número de células viáveis dos biofilmes desenvolvidos na presença de FLZ (p < 0,001). Considerando-se a proporção de polissacarídeos produzidos pelo número de células viáveis, observou-se que nos grupos experimentais, C. albicans foi capaz de produzir mais matriz extracelular do que os grupos controle (p < 0,05). Este resultado foi confirmado pelas imagens obtidas por microscopia confocal. Conclui-se que a microscopia confocal é uma ferramenta efetiva na análise da matriz extracelular de biofilmes de C. albicans, e que os biofilmes de C. albicans desenvolvidos na presença de FLZ apresentaram maior produção de matriz extracelular / Abstract: Fluconazole (FLZ) is a commonly used antifungal agent to treat patients with Candida-associated denture stomatitis. However, the success of this therapy may be compromised by the presence of extracellular matrix of C. albicans biofilms. Although studies have been conducting evaluating the effect of FLZ on C. albicans biofilms, studies that simulate the condition in which biofilms were allowed to grow in the presence of FLZ are limited. Additionally, in order to evaluate the three-dimensional organization of these biofilms, several microscopic techniques have been described, although little attempt has been paid to assess the extracellular matrix. The objective of this study was to investigate the extracellular matrix of C. albicans biofilms in the presence of salivary concentration of FLZ. For this, two studies were conducted. For both studies, discs (10 mm x 2 mm) were fabricated using poly (methyl methacrylate). Salivary pellicle was formed on disc surface and C. albicans biofilms were developed. In the first study a methodology for analyzing the extracellular matrix was defined. C. albicans ATCC 90028 biofilms were developed in culture media without (control) or with supplementation by glucose or sucrose for 72 hours. During development, biofilms were stained with Concanavalin A (ConA) in order to label the extracellular matrix. After, cells were also labeled with SYTO-9. Images obtained by confocal microscopy were analyzed by COMSTAT software. In order to confirm the results, biofilms were subjected by the biochemical phenol-sulfuric method. Data were analyzed by ANOVA followed by Tukey's test at a significance level set at 5%. For the second study, biofilms of an ATCC 90028 and two clinical isolates (, P01 and P34) were developed for 48 hours. FLZ at 2.56 ?g/mL, concentration bioavailable in saliva, was added to culture media of experimental groups. Biofilms were investigated for the number of viable cells by serial dilution and extracellular matrix production was analyzed by phenol-sulfuric method and confocal microscopy. Data were analyzed by Student's t-test, with significance level set at 5%. In the first study, the use of ConA provided an effective labeling of extracellular matrix, which was confirmed by phenol-sulfuric method (p < 0.05). In the second study, a reduction of 80% was observed in the number of viable cells for C. albicans biofilms developed in the presence of FLZ (p < 0.001). Considering the proportion of polysaccharides produced by the number of viable cells, it was observed that in the experimental groups, C. albicans was able to produce more extracellular matrix than the control groups (p < 0.05). This result was confirmed by confocal images. It was concluded that confocal microscopy is an effective tool to investigate the extracellular matrix of C. albicans biofilms; and C. albicans biofilms developed in the presence of FLZ present increased extracellular matrix production / Doutorado / Protese Dental / Doutora em Clínica Odontológica
7

The influence of mixing ratio on the fatigue behaviour of fibre reinforced polymers

Stuhlinger, Martin Ernst January 2013 (has links)
Magister Scientiae Dentium - MSc(Dent) / Statement of the problem: Fibre reinforcement of polymethyl methacrylate (PMMA) denture base material is known to improve the strength, as well as the fatigue behavior, of the material. The powder liquid (P/L) ratio of PMMA is often changed to modify the handling properties of the material. Little is known about the effect of this deviation from manufacturer’s guidelines on the fatigue behaviour of the fibre reinforced product. Purpose: This study compared the flexural strength (FS) of PMMA reinforced with glass fibre using different P/L ratios, before and after cyclic loading. Methods and materials: Three groups, with 50 glass fibre reinforced (everStick nonimpregnated fibers) heat-cured PMMA resin (Vertex Rapid Simplified) specimens each, were prepared using a custom-made template (dimensions 10x9x50mm). Each group had a different P/L ratio: the control group (100%) had the manufacturer’s recommended ratio; the 90% and 80% groups had reduced P/L ratios (by weight).Twenty five specimens from each group were subjected to a 3-point bending compression test using a universal testing machine. The remaining 25 specimens from each group were subjected to cyclic loading (104 cycles) before compression testing. The (FS) was calculated using the highest force (Fmax) before specimen failure. Flexural strength was calculated using the equation: FS=3WL/2bd2. Within each group, median FS values before and after cyclic loading were compared by means of a non-parametric analysis of variance. The Aligned Ranks Transform method was used for the analysis. Statistical significance was set at p=0.05. Results: The Fmax (N) of the control (100%), 90% and 80% groups fatigued and unfatigued were 100%: 1665 (fat), 1465 (unfat); 90%: 1679 (fat), 1548 (unfat) and 80%: 1585 (fat), 1467 (unfit) respectively. There was no significant interaction between Mix ratio and Fatigue state, and the 80% mix had a significantly higher mean than either the 90% or 100% mix (with differences of about 0.3 units for both). The Fatigued state had a higher mean than the Un- fatigued state by about 6.0 units. Using FS (MPa) it was found that the fatigued 80% mix specimens had the highest value. The FS MPa of the control (100%), 90% and 80% groups fatigued and un-fatigued were 64.3, 60.6; 66.9, 65.6 and 70.2, 69.3 respectively. The fact that fatiguing strengthened the specimens merits further research. When observing the broken specimens it was found that there was a complete debonding of the fibres and the PMMA. Conclusion and clinical relevance: a) Fibre: The benefit of using glass fibre bundles to reinforce prostheses fabricated using heat cured PMMA is questionable due to problems with bonding between the fibre bundles and the heat cured PMMA resin. b) Fatiguing: An average person chews 107 times during a 3 year period. A limited period of average masticatory forces should not have a detrimental effect on prostheses made from heat cured PMMA resin. c) Mix ratio: Within the normal parameters of laboratory techniques the mix ratio of PMMA resin had no significance on the fracture resistance of the prostheses. Due to the high cost of the fibres used for the reinforcement and the limited success and insignificant results achieved in this study, this researcher cannot recommend using Stickbond or Stick fibers for the reinforcement of dentures made with heat cured PMMA resin.
8

Water sorption, solubility and load transmission of removable partial dentures manufactured with poly (methilmetacrilate) and polyamide = Sorção de água, solubilidade em água e transmissão de forças de próteses parciais removíveis confeccionadas em poli (metilmetacrilato) e poliamida / Sorção de água, solubilidade em água e transmissão de forças de próteses parciais removíveis confeccionadas em poli (metilmetacrilato) e poliamida

Panza, Leonardo Henrique Vadenal, 1982- 24 February 2015 (has links)
Orientadores: Wander José da Silva, Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T04:08:04Z (GMT). No. of bitstreams: 1 Panza_LeonardoHenriqueVadenal_D.pdf: 39498694 bytes, checksum: bcb5576864f239980a74f85ecab13ee6 (MD5) Previous issue date: 2015 / Resumo: O uso de PPRs continua como uma alternativa viável e eficiente na prática da reabilitação oral, no entanto a necessidade do uso de uma estrutura metálica, pode muitas vezes causar um comprometimento estético. O uso de materiais alternativos flexíveis para a substituição destes grampos ou de outras partes da PPR tem sido bastante divulgado, porém ainda existem controvérsias sobre as propriedades físicas e mecânicas dos mesmos. O objetivo deste trabalho foi comparar 2 materiais utilizados na confecção de PPRs nos quesitos sorpção de água, solubilidade em água e transmissão de forças ao rebordo na extensão distal da peça. Para análise de sorpção e solubilidade foram confeccionados discos em polimetilmetacrilato (PMMA) e poliamida (POL), seguindo as especificações da ISO 1567. Para análise da transmissão de forças ao rebordo foram confeccionados modelos classe I de Kennedy em resina fotoelástica e 3 diferentes tipos de PPR: tradicional com estrutura metálica e base em PMMA (controle), PPR conjugada feita com estrutura metálica e poliamida e uma PPR confeccionada totalmente em poliamida. Os conjuntos modelo-PPR foram submetidos à cargas de 0,5 e 1,0 KgF na extensão distal e as imagens de franjas formadas nos modelos foram capturadas de forma padronizada. O teste de Kruskal-Wallis foi utiilizado para analisar os dados, que mostraram não haver diferenças significantes entre os materiais para sorpção de água (p=0.6682) e solubilidade (p=0.4095). A análise fotoelástica mostrou uma transmissão de forças mais intensa pela extensão distal da PPR nos grupos de PPRs feitas em poliamida, quando comparadas ao grupo controle, especialmente no grupo da PPR sem metal. Com as limitações deste estudo foi possível concluir que o comportamento do PMMA e da poliamida foi similar para sorpção e solubilidade em água e que a transmissão de forças ao rebordo em próteses confeccionadas em poliamida sem metal contraindicam o seu uso / Abstract: The use of removable partial denture (RPD) still remains as a viable alternative to an efficient oral rehabilitation. However, due the metal framework lack of esthetic, it has been suggested the use of flexible materials as substitutes to the metal clasps, even thought this material maintains controversial regarding its dimensional properties. In this manuscript, our group compared two materials used in the fabrication of RPD regarding its water sorption and solubility and load transmission by distal extension. For this, poly (methyl methacrylate) (PMMA) and polyamide (POL) discs (n=7) were used to manufacture specimens that were evaluated regarding its water sorption and solubility. For load transmission by distal extension, Kennedy Class I mandibular models were made with photo elastic resin and 3 different RPD were tested: traditional RPD with metal framework and PMMA flange (Control); RPD with metal framework and clasps and flange in POL (POL-Metal); and RPD totally manufactured in POL (TOT-POL). Load of 0.5 and 1.0 kgF were applied to distal extension and the image of the load transmission in the photo-elastic model was captured. Kruskal-Wallis test were used for data analysis. Results showed no statistical difference between both materials regarding water sorption (p=0.6682) and solubility (p=0.4095). Photo-elastic analyses showed higher load transmission by distal extension by both POL group when compared to control group. Within the limitations of this study, it can be concluded that although POL had similar behavior to PMMA regarding water sorption and solubility, the load transmission by distal extension in RPD manufactured with POL shows the worst results, but clinical studies should de done with this material to indicates its use / Doutorado / Protese Dental / Doutor em Clínica Odontológica
9

Synthèse de réseaux polymères thermoréversibles par réaction de Diels-Alder / Supramolecular reinforced Diels-Alder based evolutive polyurethane networks

Okhay, Nidhal 30 November 2012 (has links)
Cette étude porte sur l’application de la réaction de Diels-Alder dans la synthèse de réseaux polymères thermoréversibles ainsi que la compatibilisation de mélanges de polymères initialement immiscibles. Les polymères étudiés ne sont autres que le polyméthacrylate de méthyle et le polyuréthane. Les réseaux thermoréversibles sont obtenus par réaction de Diels-Alder faisant intervenir le couple furanne-maléimide. Les polymères fonctionnalisés furanne ou maléimide sont obtenus soit par modification chimique d’un polymère commercial (cas du PMMA) soit par réaction de polyaddition (cas du polyuréthane). Les réseaux sont ensuite obtenus par réaction de DA avec des agents de couplage maléimide (bis- ou tris-maléimide) pour les polymères fonctionnalisés furanne ou par réaction de DA avec des agents de couplage furanne pour les prépolymères fonctionnalisés maléimide. La thermo-réversibilité a été soulignée par DSC, par des tests de solubilité à chaud ainsi que par rhéologie. Des réseaux interpénétrés thermoréversibles PMMA/PU ont été également obtenu par Diels-Alder et ce grâce à la présence d’interaction supramoléculaire entre les deux phases. / This study focuses on the application of the Diels-Alder reaction in the synthesis of thermoreversible polymer networks and compatibilization of immiscible polymer blends. The studied polymers are polymethyl methacrylate and polyurethane. Thermoreversible networks were obtained by a Diels-Alder involving furan-maleimide couple. The furan or maleimide functionalized polymers were obtained either by chemical modification of a commercial polymer (case of PMMA) or by polyaddition reaction (case of polyurethane). Networks were then obtained by DA reaction with maleimide coupling agents (bis-or tris-maleimide) for furan functionalized polymers or DA reaction with furan coupling agents for maleimide functionalized prepolymers. The thermoreversibility was highlighted by DSC, solubility tests (at high temperature) as well as rheology. Thermoreversible interpenetrating PMMA/PU networks were also obtained by Diels-Alder reaction and this is due to the presence of supramolecular interaction between the two phases
10

Avaliação in vitro da citotoxicidade de resinas acrílicas para reembasamento baseadas em uma nova formulação /

Costa, Cristiane Campos. January 2009 (has links)
Resumo: O objetivo deste estudo foi determinar a citotoxicidade in vitro de duas resinas reembasadoras experimentais autopolimerizáveis contendo alta concentração de agentes de ligação cruzada, etilenoglicol dimetacrilato (EGDMA) e 1,4-butanodiol dimetacrilato (BDMA) comparadas com uma resina reembasadora comercial (Tokuyama Rebase Fast II). Foram confeccionados corpos-de-prova em forma de discos das três resinas acrílicas reembasadoras rígidas sob condições assépticas. Os fibroblastos (L929) foram cultivados em placas com 96 compartimentos e incubadas por 24 h em meio de cultura Eagle. Os extratos foram preparados, colocando-se três amostras de cada resina em frascos de vidro estéreis com 9 mL de meio de Eagle e incubadas a 37º C por 24 h. O efeito citotóxico dos extratos foram avaliados utilizando os testes de incorporação do 3H-timidina e MTT, que refletem os níveis de síntese de DNA e metabolismo celular, respectivamente. Os dados foram analisados estatisticamente, utilizando análise de variância (P<0.05). Para o teste de incorporação do 3H-timidina, não foram observadas diferenças significativas (P>0.05) entre os materiais. A média da quantidade do isótopo incorporado no DNA celular para todas as resinas acrílicas foi estatisticamente menor do que para o controle. Todas as resinas acrílicas foram classificadas pelo teste de incorporação do 3Htimidina como moderadamente citotóxicas. Da mesma forma, para o teste do MTT, não foi encontrada diferença significativa para a citotoxicidade entre os materiais (P>0.05). Quando a citotoxidade foi comparado com o grupo controle, todas as resinas foram classificadas entre não citotóxicas e discretamente citotóxicas pelo teste do MTT. Assim, conclui-se que a incorporação dos agentes de ligação cruzada, EGDMA e BDMA não influenciaram significativamente sobre a citotoxicidade observada. Não houve diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the cytotoxicity in vitro of two trials autopolymerizing reline systems made with higher concentration of cross-linking agents, EGDMA and BDMA compared to a commercial reline resin. Sample disks of the three hard reline acrylic resins were fabricated under aseptic conditions. The Fibroblast L929 cells were cultured in 96-well plates and incubated for 24 h in Eagle's medium. Eluates were prepared by placing three samples into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37ºC for 24 h. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. The data were statistically analyzed by using the one-way analysis of variance (P<.05). With the 3H-thymidine incorporation assay, no significant differences (P > .05) were found between the materials. The mean quantity of isotope incorporated into cellular DNA for all acrylic resins was statistically smaller than for the control. All acrylic resins were graded by the 3Hthymidine incorporation assay as moderate cytotoxic. Similarly, with the MTT assay, no significant difference in cytotoxicity was found between the materials (P > .05). When the cytotoxicity was compared with control group, all resins assay were between non cytotoxic and slight cytotoxic by the MTT. The incorporation of cross-linking agents, EGDMA and BDMA had no significant influence on the cytotoxicity observed. There was no cell viability difference between all materials in both assays. / Orientador: Eunice Teresinha Giampaolo / Coorientador: Iracilda Zeppone Carlos / Banca: Renata Cristina Silveira Rodrigues Ferracioli / Banca: Iracilda Zeppone Carlos / Mestre

Page generated in 0.0903 seconds