• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 1
  • Tagged with
  • 15
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Micropenetração Instrumentada em Compósitos de Matriz Metálica à Base de Tungstênio Empregados em Coroas de Perfuração Utilizadas em Sondagem Mineral

GAVA, G. H. S. 20 December 2010 (has links)
Made available in DSpace on 2016-08-29T15:32:52Z (GMT). No. of bitstreams: 1 tese_4854_Dissertação de Mestrado - Gabriel Haddad Souza Gava.pdf: 24495351 bytes, checksum: 753fa2b1d30124801793af7d963a8217 (MD5) Previous issue date: 2010-12-20 / Este trabalho tem o objetivo de avaliar uma possível relação entre as propriedades mecânicas calculadas a partir dos dados de micropenetração instrumentada e o comportamento sob desgaste microabrasivo dos compósitos à base de tungstênio (W) infiltrados por latão, usados em coroas diamantadas utilizadas em sondagem mineral. As amostras dos compósitos de tungstênio foram sinterizadas com combinações de diferentes tamanhos de partículas W e adições de ligas à base de outros elementos, além de adições de abrasivos secundários (SiC). Após a preparação metalográfica, as amostras foram analisadas em um micropenetrador instrumentado com um penetrador do tipo Vickers. As fases foram penetradas com uma carga de 30 mN, exceto o carbeto de silício, com carga de 250 mN. As curvas geradas a cada penetração permitiram calcular a microdureza e o módulo de elasticidade para cada fase. Estes resultados foram comparados com os coeficientes de desgaste microabrasivo dimensionais obtidos em um trabalho anterior, através de ensaios de microabrasão com lamas abrasivas à base de carbeto de silício, sílica e hematita, efetuados com equipamento do tipo Calowear. Foi observada uma diminuição na microdureza conforme o tamanho dos grãos de tungstênio aumenta. Para a lama abrasiva contendo SiC, uma diminuição no coeficiente de desgaste microabrasivo se seguiu à diminuição na microdureza do tungstênio. O oposto foi observado com a lama de SiO2, enquanto, para a lama de Fe2O3, nenhuma correlação clara foi obtida. Também é importante dizer que o efeito da dureza do latão infiltrado (fase aglutinante) tornou-se mais significativa nos ensaios com as pastas de SiO2 e de Fe2O3. Quando as ligas à base de outros elementos são adicionadas, para o abrasivo SiC, o aumento da plasticidade do latão aumenta o desgaste, porque as deformações plásticas são aumentadas, levando em consideração a relação Habr./Hfase muito alta. A plasticidade da fase W parece não interferir no desgaste. Ocorre o contrário para o abrasivo SiO2. Para ambos os abrasivos, o cobre adicionado aumenta a fração volumétrica de fase macia, proporcionando um desgaste ainda maior. Para o abrasivo Fe2O3, o aumento na plasticidade do latão aumenta o coeficiente de desgaste, pois leva a indentações maiores, ou seja, a maiores deformações plásticas. Dependendo do tipo do abrasivo, os mecanismos observados foram riscamento e rolamento de partículas (múltiplas indentações), além da ocorrência de ambos simultaneamente, embora dissociados. Palavras-chave: micropenetração instrumentada, microdureza, microabrasão, compósitos, tungstênio, latão.
2

Remineralização com fosfopeptídeo da caseína fosfato de cálcio amorfo do esmalte dentário microabrasionado - avaliação por tomografia por coerência óptica e microscopia eletrônica de varredura

GURGEL, Ludmila Galindo França 31 August 2015 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-27T22:30:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Ludmila Galindo França Gurgel.pdf: 2826441 bytes, checksum: 6f0231311711ba68c24b6dabae663d78 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-05T21:21:39Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Ludmila Galindo França Gurgel.pdf: 2826441 bytes, checksum: 6f0231311711ba68c24b6dabae663d78 (MD5) / Made available in DSpace on 2018-09-05T21:21:39Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Ludmila Galindo França Gurgel.pdf: 2826441 bytes, checksum: 6f0231311711ba68c24b6dabae663d78 (MD5) Previous issue date: 2015-08-31 / As manchas brancas do esmalte dentário são alterações estéticas importantes e as possibilidades conservadoras para eliminá-las são assunto de grande interesse da comunidade odontológica e da população em geral. O objetivo deste estudo foi avaliar a remineralização do esmalte microabrasionado com fosfopeptídeo da caseína fosfato de cálcio amorfo (CPP-ACP), através da tomografia por coerência óptica(OCT) e microscopia eletrônica de varredura (MEV).A amostra foi composta por 35 terceiros molares humanos hígidos, seccionados ao meio no sentido axial (n=70), distribuída da seguinte forma: G1, controle (n=10), G2, microabrasão com ácido fosfórico 37% (n=30) eG3, microabrasão com ácido hidroclorídrico 6,6% (Opalustre, Ultradent) (n=30). G2e G3 foram subdivididos em subgrupos, G2A/G3A, sem agente remineralizante(n=10), G2B/G3B,aplicação de solução remineralizante acetato-flúor(n=10), e os G2C/G3C, com aplicação do gel de fosfopeptídeo da caseína-fosfato de cálcio amorfo(CPP-ACP) (n=10). Os resultados mostraram que o OCT detectou as mudanças da superfície dentária microabrasionada e registrou um maior retroespalhamento da luz nas amostras tratadas com ácido hidroclorídrico 6,6%.G2C se assemelhou ao esmalte dentário hígido. As imagens de MEV confirmaram este achado, exibindo a preservação da morfologia dos prismas do esmalte dentário. Isto sugere que a microabrasão com ácido fosfórico 37% /CPP-ACP é o protocolo mais indicado. / OCR
3

ANÁLISE do Comportamento Tribológico em Ensaios de Microabrasão da Superliga de Cobalto Co-30cr-19fe Nitretada a Plasma

VIEIRA, L. B. 14 July 2017 (has links)
Made available in DSpace on 2018-08-02T00:03:00Z (GMT). No. of bitstreams: 1 tese_11451_LEONARDO BELICHI VIEIRA.pdf: 3099921 bytes, checksum: 62dfc10b00baf239179bbfea18ad51b1 (MD5) Previous issue date: 2017-07-14 / A aplicação de ligas de cobalto, como a Co-30Cr-19Fe, em componentes usados na produção de etanol de 2ª geração vem sendo estudada. Neste processo, cerca de 8% da carga trabalhada no reator é composta por partículas duras, principalmente sílica. Dessa forma, existe a necessidade de promover o aumento da resistência ao desgaste abrasivo dos componentes do reator. Em meio a este contexto, amostras da superliga de cobalto fundida Co-30Cr19Fe foram submetidas a um tratamento de solubilização e na sequência nitretadas a plasma em baixas temperaturas, objetivando a formação de uma camada dura, resistente ao desgaste e livre de precipitados, conhecida na literatura como fase-S ou austenita expandida. A liga apresentou microestrutura predominantemente homogênea e estrutura cristalina mista, com fases de cobalto α (CFC) e ε (HC). A solubilização foi feita à temperatura de 1200 °C e tempo de tratamento de 8 horas. Três condições de nitretação a plasma foram escolhidas, as temperaturas utilizadas foram de 325, 350 e 400 °C, em todos os casos a mistura gasosa foi de 75% de H2 e 25% de N2, tempo de tratamento de 20 horas e pressão de trabalho de 2,5 Torr. As amostras foram caracterizadas antes e após cada tratamento, utilizando microscopia ótica, medidas de microdureza e difração de raios X. Os ensaios de microabrasão foram realizados no microabrasômetro da marca PLINT modelo TE66, os abrasivos SiO2, Al2O3 e SiC, em suspensão em água destilada e com concentração de 0,1 g/cm3, foram utilizados. O Universal Micro Tester modelo APEX da CETR/Bruker foi empregado nos ensaios de esclerometria retilínea uniforme. O tratamento de solubilização resultou em uma microestrutura mais homogênea, com redução do tamanho médio dos precipitados e dissolução apenas parcial destes, a estrutura do material permaneceu mista. A solubilização não promoveu mudanças importantes na dureza e na resistência ao desgaste do material. A fase-S foi obtida em todas as condições, porém, à temperatura de 400 °C, houve precipitação de nitretos de cromo. A espessura e a dureza das camadas aumentaram de acordo com o acréscimo da temperatura de nitretação. De forma geral, a resistência ao desgaste aumentou após a formação das camadas. As amostras solubilizadas e nitretadas a 350 °C apresentaram, mesmo que ligeiramente, menores coeficientes de desgaste. O abrasivo que proporcionou maior coeficiente de desgaste foi a Al2O3, seguido por SiC e SiO2. O micromecanismo de desgaste dominante em todos os ensaios foi o de abrasão a dois corpos, riscamento. Quando aplicadas pequenas cargas, a fase-S promoveu aumento da dureza ao risco da superliga Co-30Cr-19Fe.
4

Remoção de irregularidades superficiais do esmalte dental após a remoção de braquetes ortodônticos : efeito de polimentos superficiais e tempos de análise /

Franco, Laura Molinar. January 2017 (has links)
Orientador: Renato Herman Sundfeld / Coorientador: Lucas Silveira Machado / Banca: André Pinheiro de Magalhães Bertoz / Banca: Sergio Kiyoshi Ishikiriama / Banca: Elaine Cristina Guerbach Conti / Banca: Rodolfo Brunieira Anchieta / Resumo: O objetivo deste ensaio clínico foi avaliar o comportamento de dois sistemas de polimento na regularização da superfície do esmalte dental, que apresentava-se rugosa e irregular após a remoção de braquetes ortodônticos. As variáveis de resposta foram: rugosidade superficial, luminosidade, morfologia, textura e sensibilidade. Fizeram parte dessa pesquisa clínica 30 voluntários. Os fatores em estudo foram: as técnicas de poli- mento superficial em dois níveis: Técnica 1 (discos de óxido de alumínio) e Técnica 2 (produto ácido-abrasivo), e o tempo de análise em 5 níveis: T0 (baseline), T1 (imedia- tamente após os polimentos superficiais), T2 (após polimento final), T3 (7 dias após os procedimentos) e T4 (6 meses após os procedimentos). Os dados representados por escores foram analisados considerando distribuição multinomial; os dados numéricos foram analisados como medidas repetidas no tempo, a um nível de significância de 5%. Nas análises de rugosidade superficial e luminosidade, não houve diferença estatística entre as técnicas em todos os tempos analisados. Nas análises por score, dentro de cada tempo, verificou-se igualdade significativa apenas no baseline; nos demais tempos foram observadas irregularidades superficiais estatisticamente superiores para a Técnica 1. Nenhum paciente apresentou sensibilidade dental. Ambas as técnicas foram eficientes; porém a maior lisura foi adquirida quando a Técnica 2 foi utilizada. / Abstract: This clinical study evaluated the behavior of two surface polishing systems in the regularization of the enamel surface, which was rough and irregular after orthodontic brackets debonding. The response variables were: surface roughness, lightness, morphology, texture and sensitivity. Thirty volunteers were part of this clinical research. The factors under study were: Surface polishing at two levels: Technique 1 (aluminum oxide disks) and Technique 2 (enamel microabrasive product); and the Time of analysis at 5 levels: T0 (after surface polishing), T1 (immediately after surface polishing), T2 (after final polishing), T3 (7 days after surface polishing) and T4 (6 months after surface polishing). The data represented by scores were analyzed considering multinomial distribution; the numerical ones were analyzed as measures repeated in time, at a significance level of 5%. In the analysis of surface roughness and lightness, there was no statistical difference between the polishing techniques at all times analyzed. In the other analyzes, within each time, significant equality was observed only in the baseline, while in the other times superficial irregularities were statistically superior for Technique 1. No patient presented dental sensitivity. Both techniques were efficient; however, the higher surface smoothness was observed on the dental enamel surface polished with the Technique 2 / Doutor
5

Efeito da microabrasão e do clareamento dental na rugosidade superficial e microdureza do esmalte dental: estudo longitudinal ‘in situ’

Franco, Laura Molinar [UNESP] 21 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-21Bitstream added on 2015-03-03T12:06:56Z : No. of bitstreams: 1 000796548.pdf: 2383926 bytes, checksum: 065a6fc930609635eb619145c33a7140 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho in situ foi avaliar se a associação da microabrasão do esmalte com o clareamento dental causaria danos às propriedades do esmalte dental microabrasionado, através dos testes de rugosidade superficial, de microdureza do esmalte dental e de microscopia eletrônica por varredura. Os fatores em estudo foram: técnicas em 5 níveis: controle, microabrasão (Opalustre – Ultradent Products Inc. Utah, USA), clareamento dental (Opalescence Boost PF 38 % - Ultradent Prodcuts Inc. Utah, USA) e a associação dos dois procedimentos (imediata e tardia); assim como o tempo de manutenção dos espécimes in situ: 0, 1, 3, 7 dias. As variáveis de resposta foram microdureza e a rugosidade superficial. Foram utilizados 50 dentes bovinos hígidos, seccionados em discos de esmalte/dentina com 5,7mm de diâmetro. Os espécimes selecionados foram aleatoriamente divididos em 5 grupos de estudo (n=10): Grupo Controle + 0, 1, 3, 7 dias in situ; GI Clareamento + 0, 1, 3, 7 dias in situ; GII Microabrasão + 0, 1, 3, 7 dias in situ; GIII Microabrasão + Clareamento + 0, 1, 3, 7 dias in situ e GIV Microabrasão + 0, 1, 3, 7 dias in situ + Clareamento. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) para medidas repetidas, seguidas pelo teste de Tukey a 5%. Foi observado que a rugosidade superficial do esmalte dental não foi alterada pela realização do clareamento dental com/sem período in situ, mas foi significativamente influenciada pela realização da microabrasão associada ou não com o clareamento dental, com/sem período in situ. Já a microdureza do esmalte dental, em uma comparação entre grupos, sofreu redução significativa nos grupos onde a microabrasão do esmalte foi realizada, independente da associação com o clareamento dental; sendo que após o período in situ observou-se o reestabelecimento da microdureza... / The aim of this in situ study was to evaluate if the association of microabrasion enamel with dental bleaching causes damage to microabrasioned enamel properties, through the surface roughness, hardness of dental enamel and scanning electron microscopy tests. The factors under study were: procedure on 5 levels: control, microabrasion (Opalustre - Ultradent Products Inc. Utah, USA), dental bleaching (Opalescence Boost PF 38 % - Ultradent Prodcuts Inc. Utah, USA) and the association of the two procedures (immediate and late), as well as the maintenance time of the specimens in situ: 0, 1, 3, 7 days. The response variables were microhardness and surface roughness. Fifty healthy bovine teeth were used, sectioned into discs of enamel/dentin with 5.7 mm diameter. The selected specimens were randomly divided into 5 groups (n=10): control group + 0 , 1 , 3 , 7 days in situ; GI dental bleaching + 0, 1, 3, 7 days in situ; GII Microabrasion + 0, 1, 3, 7 days in situ; GIII Microabrasion + dental bleaching + 0, 1, 3, 7 days in situ and GIV Microabrasion + 0, 1, 3, 7 days in situ + dental bleaching. The results were subjected to two way repeated measures ANOVA for followed by the Tukey test at 5 %. It was observed that the enamel roughness surface was not altered by dental bleaching, with/without in situ period, but was significantly influenced by microabrasion, associated or not with dental bleaching, with/without in situ period; whereas the enamel microhardness, in a comparison between groups, was significantly decreased in the groups where enamel microabrasion was performed, regardless of association with dental bleaching; after the in situ period, there was satisfactory reestablishment of enamel microhardness. It can be conclude that the association of enamel microabrasion with dental bleaching does not cause damage on microabrasioned enamel properties. / FAPESP: 12/06271-3
6

Efeito da microabrasão e do clareamento dental na rugosidade superficial e microdureza do esmalte dental : estudo longitudinal 'in situ' /

Franco, Laura Molinar. January 2014 (has links)
Orientador: Renato Herman Sundfeld / Banca: Ticiane Cestari Fagundes / Banca: Márcio Grama Hoeppner / Resumo: O objetivo deste trabalho in situ foi avaliar se a associação da microabrasão do esmalte com o clareamento dental causaria danos às propriedades do esmalte dental microabrasionado, através dos testes de rugosidade superficial, de microdureza do esmalte dental e de microscopia eletrônica por varredura. Os fatores em estudo foram: técnicas em 5 níveis: controle, microabrasão (Opalustre - Ultradent Products Inc. Utah, USA), clareamento dental (Opalescence Boost PF 38 % - Ultradent Prodcuts Inc. Utah, USA) e a associação dos dois procedimentos (imediata e tardia); assim como o tempo de manutenção dos espécimes in situ: 0, 1, 3, 7 dias. As variáveis de resposta foram microdureza e a rugosidade superficial. Foram utilizados 50 dentes bovinos hígidos, seccionados em discos de esmalte/dentina com 5,7mm de diâmetro. Os espécimes selecionados foram aleatoriamente divididos em 5 grupos de estudo (n=10): Grupo Controle + 0, 1, 3, 7 dias in situ; GI Clareamento + 0, 1, 3, 7 dias in situ; GII Microabrasão + 0, 1, 3, 7 dias in situ; GIII Microabrasão + Clareamento + 0, 1, 3, 7 dias in situ e GIV Microabrasão + 0, 1, 3, 7 dias in situ + Clareamento. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) para medidas repetidas, seguidas pelo teste de Tukey a 5%. Foi observado que a rugosidade superficial do esmalte dental não foi alterada pela realização do clareamento dental com/sem período in situ, mas foi significativamente influenciada pela realização da microabrasão associada ou não com o clareamento dental, com/sem período in situ. Já a microdureza do esmalte dental, em uma comparação entre grupos, sofreu redução significativa nos grupos onde a microabrasão do esmalte foi realizada, independente da associação com o clareamento dental; sendo que após o período in situ observou-se o reestabelecimento da microdureza... / Abstract: The aim of this in situ study was to evaluate if the association of microabrasion enamel with dental bleaching causes damage to microabrasioned enamel properties, through the surface roughness, hardness of dental enamel and scanning electron microscopy tests. The factors under study were: procedure on 5 levels: control, microabrasion (Opalustre - Ultradent Products Inc. Utah, USA), dental bleaching (Opalescence Boost PF 38 % - Ultradent Prodcuts Inc. Utah, USA) and the association of the two procedures (immediate and late), as well as the maintenance time of the specimens in situ: 0, 1, 3, 7 days. The response variables were microhardness and surface roughness. Fifty healthy bovine teeth were used, sectioned into discs of enamel/dentin with 5.7 mm diameter. The selected specimens were randomly divided into 5 groups (n=10): control group + 0 , 1 , 3 , 7 days in situ; GI dental bleaching + 0, 1, 3, 7 days in situ; GII Microabrasion + 0, 1, 3, 7 days in situ; GIII Microabrasion + dental bleaching + 0, 1, 3, 7 days in situ and GIV Microabrasion + 0, 1, 3, 7 days in situ + dental bleaching. The results were subjected to two way repeated measures ANOVA for followed by the Tukey test at 5 %. It was observed that the enamel roughness surface was not altered by dental bleaching, with/without in situ period, but was significantly influenced by microabrasion, associated or not with dental bleaching, with/without in situ period; whereas the enamel microhardness, in a comparison between groups, was significantly decreased in the groups where enamel microabrasion was performed, regardless of association with dental bleaching; after the in situ period, there was satisfactory reestablishment of enamel microhardness. It can be conclude that the association of enamel microabrasion with dental bleaching does not cause damage on microabrasioned enamel properties. / Mestre
7

Avaliação da molhabilidade e resistência ao desgaste abrasivo de compósitos do tipo epóxi /quasicristais (AlCuFe)

MARTINS, José Lucas Pessoa 27 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-08-18T14:59:23Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) KGBA_15022016LUCAS1.pdf: 4588819 bytes, checksum: 532522f49862cfc44ad001b8b5a0413f (MD5) / Made available in DSpace on 2016-08-18T14:59:23Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) KGBA_15022016LUCAS1.pdf: 4588819 bytes, checksum: 532522f49862cfc44ad001b8b5a0413f (MD5) Previous issue date: 2015-08-27 / CAPEs / No presente trabalho foram produzidos compósitos a base de epóxi reforçados com liga quasicristalina AlCuFe, para ensaios de microabrasão e molhabilidade. A liga AlCuFe foi produzida num forno de indução de soleira fria com materias de até 99,99% de pureza e submetida ao tratamento térmico por 24h a uma temperatura de 750°C. O quasicristal foi utilizado na forma de pó após moagem em moinho planetário. A caracterização do quasicristal (QC) foi realizada com uso das técnicas de difração de raios x (DRX) e microscopia eletrônica de varredura (MEV). Análises de DRX mostraram fase cristalina bem definida para amostras de QC, por sua vez imagens de MEV indicaram morfologia arredondada do QC e com uso do software IMAGE J, foi possível observar diâmetros de partícula em torno de 5,48±1,83μm. Em adição, o pó metálico foi misturado com uma resina epóxi em proporções de 5%, 10% e 15% em volume, sendo a cura estabelecida em temperatura ambiente. Por sua vez, as propriedades de molhabilidade e microabrasão foram avaliadas. Verificamos que, com o aumento na proporção em volume de quasicristal no compósito, ocorreram alterações significativas no módulo do coeficiente de desgaste, bem como obtenção de maiores valores no ângulo de contato, tornando o material mais hidrofóbico. As imagens de MEV do compósito indicaram os mecanismos de desgaste envolvidos durante o ensaio de microabrasão, levando ao aumento da taxa de desgaste em função da proporção volumétrica de QC no compósito. / In this paper were produced epoxy-based composites reinforced with quasicristalina league AlCuFe to microabrasion and wettability tests. The AlCuFe alloy was produced in a cold hearth induction furnace with materials of up to 99.99% purity and subjected to heat treatment for 24 hours at a temperature of 750 ° C. The quasicristal was used in powder form after milling in a planetary mill. The characterization of quasicristal (QC) has been performed using the techniques of X-ray diffraction (XRD) and scanning electron microscopy (SEM). XRD analysis showed well defined crystalline phase for QC samples in turn SEM images indicated rounded morphology and QC using Image J software, it was possible to observe particle diameters around 5.48 ± 1,83μm. In addition, the metal powder was mixed with an epoxy resin proportions of 5%, 10% and 15% by volume being established cure at room temperature. In turn, the properties of wettability and microabrasion were evaluated. We found that, with increasing volume ratio of the composite quasicristal, significant changes in the wear coefficient module and obtaining the higher values of contact angle, making it more hydrophobic. The composite SEM images indicate the wear mechanisms involved during microabrasion test, leading to increased wear rate as a function of the volumetric ratio of QC in the composite.
8

Remoção de irregularidades superficiais do esmalte dental após a remoção de braquetes ortodônticos: efeito de polimentos superficiais e tempos de análise / Removal of enamel surface irregularities after orthodontic bracket debonding: effect of surface polishing and analysis time

Franco, Laura Molinar [UNESP] 29 August 2017 (has links)
Submitted by LAURA MOLINAR FRANCO null (lauramf3@hotmail.com) on 2017-10-02T16:32:03Z No. of bitstreams: 1 TESE Laura 2017 Biblioteca.pdf: 3853664 bytes, checksum: 3266da5ff489ed61060498df4a53af0f (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-10-03T16:00:09Z (GMT) No. of bitstreams: 1 franco_lm_dr_araca.pdf: 3853664 bytes, checksum: 3266da5ff489ed61060498df4a53af0f (MD5) / Made available in DSpace on 2017-10-03T16:00:09Z (GMT). No. of bitstreams: 1 franco_lm_dr_araca.pdf: 3853664 bytes, checksum: 3266da5ff489ed61060498df4a53af0f (MD5) Previous issue date: 2017-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste ensaio clínico foi avaliar o comportamento de dois sistemas de polimento na regularização da superfície do esmalte dental, que apresentava-se rugosa e irregular após a remoção de braquetes ortodônticos. As variáveis de resposta foram: rugosidade superficial, luminosidade, morfologia, textura e sensibilidade. Fizeram parte dessa pesquisa clínica 30 voluntários. Os fatores em estudo foram: as técnicas de poli- mento superficial em dois níveis: Técnica 1 (discos de óxido de alumínio) e Técnica 2 (produto ácido-abrasivo), e o tempo de análise em 5 níveis: T0 (baseline), T1 (imedia- tamente após os polimentos superficiais), T2 (após polimento final), T3 (7 dias após os procedimentos) e T4 (6 meses após os procedimentos). Os dados representados por escores foram analisados considerando distribuição multinomial; os dados numéricos foram analisados como medidas repetidas no tempo, a um nível de significância de 5%. Nas análises de rugosidade superficial e luminosidade, não houve diferença estatística entre as técnicas em todos os tempos analisados. Nas análises por score, dentro de cada tempo, verificou-se igualdade significativa apenas no baseline; nos demais tempos foram observadas irregularidades superficiais estatisticamente superiores para a Técnica 1. Nenhum paciente apresentou sensibilidade dental. Ambas as técnicas foram eficientes; porém a maior lisura foi adquirida quando a Técnica 2 foi utilizada. / This clinical study evaluated the behavior of two surface polishing systems in the regularization of the enamel surface, which was rough and irregular after orthodontic brackets debonding. The response variables were: surface roughness, lightness, morphology, texture and sensitivity. Thirty volunteers were part of this clinical research. The factors under study were: Surface polishing at two levels: Technique 1 (aluminum oxide disks) and Technique 2 (enamel microabrasive product); and the Time of analysis at 5 levels: T0 (after surface polishing), T1 (immediately after surface polishing), T2 (after final polishing), T3 (7 days after surface polishing) and T4 (6 months after surface polishing). The data represented by scores were analyzed considering multinomial distribution; the numerical ones were analyzed as measures repeated in time, at a significance level of 5%. In the analysis of surface roughness and lightness, there was no statistical difference between the polishing techniques at all times analyzed. In the other analyzes, within each time, significant equality was observed only in the baseline, while in the other times superficial irregularities were statistically superior for Technique 1. No patient presented dental sensitivity. Both techniques were efficient; however, the higher surface smoothness was observed on the dental enamel surface polished with the Technique 2.
9

Micropenetração instrumentada em compósitos de matriz metálica à base de tungstênio empregados em coroas de perfuração utilizadas em sondagem mineral

Gava, Gabriel Haddad Souza 20 December 2010 (has links)
Made available in DSpace on 2016-12-23T14:08:14Z (GMT). No. of bitstreams: 1 Capa, Cap 1 e Cap 2 ate secao 2-2-1-9.pdf: 1005078 bytes, checksum: 68579a03ea37b6d408ea44008ec9ad0f (MD5) Previous issue date: 2010-12-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho tem o objetivo de avaliar uma possível relação entre as propriedades mecânicas calculadas a partir dos dados de micropenetração instrumentada e o comportamento sob desgaste microabrasivo dos compósitos à base de tungstênio (W) infiltrados por latão, usados em coroas diamantadas utilizadas em sondagem mineral. As amostras dos compósitos de tungstênio foram sinterizadas com combinações de diferentes tamanhos de partículas W e adições de ligas à base de outros elementos, além de adições de abrasivos secundários (SiC). Após a preparação metalográfica, as amostras foram analisadas em um micropenetrador instrumentado com um pen etrador do tipo Vickers. As fases foram penetradas com uma carga de 30 mN, exceto o carbeto de silício, com carga de 250 mN. As curvas geradas a cada penetração permitiram calcular a microdureza e o módulo de elasticidade para cada fase. Estes resultados foram comparados com os coeficientes de desgaste microabrasivo dimensionais obtidos em um trabalho anterior, através de ensaios de microabrasão com lamas abrasivas à base de carbeto de silício, sílica e hematita, efetuados com equipamento do tipo Calowear. Foi observada uma diminuição na microdureza conforme o tamanho dos grãos de tungstênio aumenta. Para a lama abrasiva contendo SiC, uma diminuição no coeficiente de desgaste microabrasivo se seguiu à diminuição na microdureza do tungstênio. O oposto foi observado com a lama de SiO2, enquanto, para a lama de Fe2O3, nenhuma correlação clara foi obtida. Também é importante dizer que o efeito da dureza do latão infiltrado (fase aglutinante) tornou-se mais significativa nos ensaios com as pastas de SiO2 e de Fe2O3. Quando as ligas à base de outros elementos são adicionadas, para o abrasivo SiC, o aumento da plasticidade do latão aumenta o desgaste, porque as deformações plásticas são aumentadas, levando em consideração a relação Habr./Hfase muito alta. A plasticidade da fase W parece não interferir no desgaste. Ocorre o contrário para o abrasivo SiO2. Para ambos os abrasivos, o cobre adicionado aumenta a fração volumétrica de fase macia , proporcionando um desgaste ainda maior. Para o abrasivo Fe2O3, o aumento na plasticidade do latão aumenta o coeficiente de desgaste, pois leva a indentações maiores, ou seja, a maiores deformações plásticas. Dependendo do tipo do abrasivo, os mecanismos observados foram riscamento e rolamento de partículas (múltiplas indentações), além da ocorrência de ambos simultaneamente, embora dissociados / This work intends to evaluate a possible relationship between the mechanical properties calculated from instrumented microindentation data and the microabrasive wear behavior of infiltrated tungsten (W) composites used in impregnated diamond bits for rock drilling. Specimens of brass-infiltrated W composites were sintered with combinations of different W particle sizes, and additions of alloys based on other elements, as well as additions of secondary abrasives. After metallographic preparation, the specimens were analyzed in an instrumented microindenter with a Vickers indenter. All phases were indented with a load of 30 mN, except the silicon carbide, with a load of 250 mN. The indentation curves allowed the calculation of microhardness and Young s modulus for each phase. Those results were compared with dimensional microabrasive wear coefficients obtained in a previous work, by testing microabrasion with abrasive slurries based on silicon carbide, silica and hematite, performed with Calower equipment. It was observed a decrease in microhardness as the tungsten grains size increase. For the SiC abrasive slurry, a decrease in microabrasive wear coefficient followed the decrease in tungsten microhardness. The opposite was observed with the SiO2 slurry, whereas, for the Fe2O3 slurry, no clear correlation was obtained. It is also important to say that the effect of infiltrated brass (binder phase) hardness became more significant in the tests with the SiO2 and Fe2O3 slurries. When the alloys based on other elements are added, to the SiC abrasive, the increase of the brass plasticity increases its wear, because the plastic deformations are increased, taking into account the very high Habr./Hphase relation. The plasticity of the W phase seems not to interfere in wear. The opposite is true for the SiO2 abrasive. For both abrasives, the copper added increases the "soft" phase volumetrical fraction, providing an additional wear. For the Fe2O3 abrasive, the increase in the brass plasticity increases the wear coefficient, since it leads to larger indentations, i. e., to larger plastic deformations. Depending on the abrasive type, the observed mechanisms were grooving and particles rolling (multiple indentations), besides the occurrence of both simultaneously, although, dissociated
10

Influência da condição superficial na resistência ao desgaste microabrasivo do aço AISI H13 / Influence of surface condition on microabrasive wear resistance of AISI H13 steel

Morozo, Mário Augusto 30 August 2013 (has links)
Made available in DSpace on 2016-12-08T17:19:21Z (GMT). No. of bitstreams: 1 Mario Augusto Morozo.pdf: 3275631 bytes, checksum: 146bb363d630204d1f0a795658dce502 (MD5) Previous issue date: 2013-08-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work, solid boriding thermochemical treatment was carried out using Ekabor® 1-V2 and heat treatment for hardening and tempering hot work tool steel AISI H13 in order to compare and evaluate the tribological behavior and properties acquired for four conditions studied, namely: boriding with Ekabor used powder ® 1-V2, boriding with Ekabor new powder ® 1-V2, quenched and tempered, and as supplied (annealed). Fixed-ball Microabrasive wear tests were performed to evaluate the steady-state wear, wear coefficient, wear volume and friction coefficient. After wear tests, the samples were transversally cut for metallographic evaluations by optical microscopy and microhardness. The wear mechanisms were analyzed by scanning electron microscopy. X-ray diffraction was used to confirm the formation of a borided layer. The results showed that the layer formed after the boriding with Ekabor ® 1-V2 used powder had become quite uneven, which may directly influence in reducing the wear resistance. The same irregularity was detected after boriding with Ekabor® 1-V2 new powder. However, for this second condition, in all áreas, thicker layer was noted. The quenched and tempered condition had the highest average wear coefficient, followed by the annealed condition and boride powder Ekabor ® 1-V2 used, whose coefficients were virtually identical. The boride with Ekabor new powder ® 1-V2 had the lowest average wear coefficient. / Neste trabalho foi realizado tratamento termoquímico de boretação por via sólida com pó comercial Ekabor® 1-V2 e tratamento térmico de têmpera e revenimento em aço ferramenta para trabalho a quente AISI H13 com o intuito de comparar e avaliar o comportamento tribológico e as propriedades adquiridas para quatro condições estudadas, sendo elas: boretação com pó Ekabor® 1-V2 usado, boretação com pó Ekabor® 1-V2 novo, condição temperada e revenida e condição como fornecida (recozida). Ensaios de desgaste microabrasivo foram realizados em equipamento de microabrasão do tipo esfera fixa para avaliação da obtenção do regime permanente de desgaste, coeficiente de desgaste, volume de desgaste e coeficiente de atrito. Após os ensaios de desgaste as amostras foram cortadas transversalmente para avaliação metalográfica através de microscopia óptica e microdureza. Os mecanismos de desgaste foram analisados por microscopia eletrônica de varredura. Difratometria de raios-X foi utilizada para a comprovação da formação da camada de boretos. Os resultados mostraram que a camada formada após a boretação com pó Ekabor® 1-V2 usado apresentou-se bastante irregular, o que pode ter influenciado diretamente na redução da resistência ao desgaste. A mesma irregularidade foi verificada após a boretação com pó Ekabor® 1-V2 novo. Entretanto, para esta segunda condição, em todas as regiões se observou uma espessura de camada maior. A condição temperada e revenida apresentou o maior coeficiente de desgaste médio, sendo seguida pelas condições recozida e boretada com pó Ekabor® 1-V2 usado, cujos coeficientes foram praticamente idênticos. A condição boretada com pó Ekabor® 1-V2 novo apresentou o menor coeficiente de desgaste médio.

Page generated in 0.0389 seconds