• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 204
  • 65
  • 40
  • 23
  • 9
  • 7
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 431
  • 97
  • 61
  • 47
  • 46
  • 43
  • 39
  • 35
  • 30
  • 29
  • 29
  • 28
  • 26
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Development of Nanoelectroporation-based Biochips for Living Cell Interrogation and Extracellular Vesicle Engineering

Shi, Junfeng, Leng January 2017 (has links)
No description available.
82

Precision Excimer Laser Lithography for Cylindrical Substrates With Thick Photoresists

Cole, Robert Lawrence 07 October 2004 (has links)
No description available.
83

Fabrication and Characterization of a Pulsed MEMS-based Micro Flow Sensor for Microfluidic Applications

Okulan, Nihat January 2000 (has links)
No description available.
84

Design, engineering,and evaluation of a novel microgrid electrode array to monitor the electrical activity on the surface of the cerebral cortex

Kitzmiller, Joseph Paul 18 June 2004 (has links)
No description available.
85

Polymer Microelectromechanical Systems: Fabrication and Applications in Biology and Biological Force Measurements

Ferrell, Nicholas Jay 19 March 2008 (has links)
No description available.
86

Nanoscale Interface Studies of a Microprojector and Water Fern

Hunt, James N. 22 July 2011 (has links)
No description available.
87

Contribution au développement d'interfaces neuro-électroniques / Contribution to the development of neuro-electric interfaces

Cottance, Myline 21 November 2014 (has links)
Les travaux menés au cours de cette thèse portent sur la microfabrication d'interfaces neuro-électroniques pour des applications en neurosciences. Nous avons choisi de nos focaliser sur la réhabilitation fonctionnelle motrice et sensorielle en développant différentes matrices de micro-électrodes (MEA) respectivement, des sondes neuronales rigides et des implants rétiniens souples. Selon les applications visées, deux types de substrats ont été utilisés pour concevoir ces MEA. Pour des analyses ou expériences in-vitro, les MEA (sondes neuronales) ont plutôt été réalisées sur des substrats rigides tels que le silicium ou le verre, tandis que pour les expériences in-vivo, les MEA (implants rétiniens) ont été réalisées sur des substrats souples tels que des polymères biocompatibles (polyimide ou parylène). Ces MEA ont été fabriquées avec différents matériaux d'électrodes (diamant dopé, platine, platine noir et or) qui ont également été testés afin de déterminer leur capacité en enregistrement et/ou stimulation. De plus, à l'aide de travaux de modélisation numérique, nous avons validé le concept d'une géométrie tridimensionnelle avec grille de masse permettant une stimulation plus focale des cellules. Cette thèse a ainsi contribué à stabiliser différents procédés de fabrication pour obtenir des MEA plus reproductibles ainsi que pour améliorer leur rendement. Elle a également permis d'établir un suivi et un protocole expérimental pour assurer une traçabilité des MEA et contrôler leur performances à toutes les étapes : depuis leur fabrication au moyen de techniques électrochimiques (CV, EIS) jusqu'aux expériences biologiques in-vitro et in-vivo / The work lead during this thesis deals with microfabrication of neuro-electronic interfaces for neuroscience applications. We have chosen to focus on motor and sensory function rehabilitations by developing Micro-Electrode Arrays (MEA) respectively, rigid neural probes and flexible retinal implants. According to the targeted applications, two types of substrates have been used to achieve these MEA. For analysis or in vitro experiments, neural probes MEA have been realized on rigid substrates such as silicon or glass whereas for in-vivo experiments, retinal implants MEA have been realized on flexible substrates such as biocompatible polymers (polyimide or parylene). These MEA were made with different electrode materials (boron doped diamond, platinum, black platinum and gold) which have been tested to determine their capability in recording and/or stimulation. Moreover, with numerical modelling work, we have validated a tridimensional geometry concept with a ground grid which permits a more local stimulation of cells. This thesis has contributed to stabilize different fabrication processes to obtain more repeatable MEA and also to improve their yield. It also allowed the set-up of a follow-up and an experimental protocol to insure MEA traceability and to monitor their performances at each step since their fabrication through means of electrochemical techniques (CV, EIS) to in vitro and in-vivo biological experiments
88

Grafted and Crosslinkable Polyphenyleneethynylene: Synthesis, Properties and Their Application

Wang, Yiqing 28 November 2005 (has links)
This thesis presents the first reported grafted PPE - polycaprolactone-g-PPE; the first PPE based sensing model: biotinylated grafted PPE/streptavidin coated sphere; the first photocrosslinkable PPE ¨C allyloxy PPE; and the new mechanism which demonstrates morphology control on a single molecular level
89

Micro-générateurs piézoélectriques pour des applications de récupération d'énergie / Piezoelectric micro-generators for energy harvesting applications

Trioux, Emilie 25 November 2015 (has links)
Le sujet de ce travail de thèse s'inscrit dans la récupération d'énergie thermique à l'échelle microscopique pour proposer une alternative aux matériaux thermoélectriques. L'objectif est de concevoir, fabriquer et caractériser un récupérateur microscopique pour tirer profit de l'augmentation des échanges thermiques et des fréquences d'oscillations avec la réduction d'échelle. Il est basé sur une double transduction, thermo-mécanique grâce au flambage d'une poutre bi-couche initialement courbe, et piézoélectrique.Des structures rectangulaires de différents tailles à base d'AlN et d'Al ont été fabriquées et caractérisées. La courbure transverse des plaques rectangulaires étant trop importante, des structures optimisées en forme de papillons ont par ailleurs été fabriquées et caractérisées. / This PhD thesis focuses on the thermal energy harvesting at microscale to propose an alternative to thermoelectric materials. The aim is to conceive, fabricate and characterize a microscopic harvester to take profit of the increase of thermal exchanges and oscillation frequencies with the downscaling. It is based on a double-step transduction: thermo-mecanical one thanks to the thermal buckling of a bilayer plate initially curved, and piezoelectric.Rectangular structures of different sizes composed of AlN and Al have been fabricated and characterized. The transverse curvature of the rectangular plate being to high, optimized structures having a butterfly shape have also been fabricated and characterized.
90

Conception et réalisation d'un microgénérateur piézoélectrique basse fréquence pour pacemaker sans fil / Design and fabrication of a low frequency microgenerator for leadless pacemaker

Colin, Mikaël 28 June 2016 (has links)
Le domaine de l’assistance cardiaque connait actuellement une rupture technologique avec l’apparition du pacemaker sans fil. Grâce à ces nouveaux dispositifs, la prise en charge des patients est simplifiée. En outre, la suppression des sondes devenues obsolètes devrait permettre une réduction drastique des problèmes rencontrés avec les pacemakers traditionnels. Cependant, la question de l’alimentation reste posée. Dans ce travail de thèse, nous tentons d’apporter une solution à base de microgénérateur piézoélectrique inertiel récupérant une portion de l’énergie vibratoire des battements cardiaques. La démarche suivie consiste tout d’abord à définir le besoin et la pertinence d’une solution à base de récupérateur d’énergie. Nous analysons ensuite l’allure de signaux cardiaques qui ont été enregistrés à l’aide d’accéléromètres directement positionnés sur le site de stimulation. On montre ainsi que le gisement vibratoire adressé (i.e. les battements cardiaques) imposent des récupérateurs vibrant aux alentours de 16 Hz. Ces fréquences sont extrêmement faibles en comparaison des microgénérateurs présentés dans la littérature (typ. > 100 Hz). Dans un second temps, et indépendamment de considérations purement technologiques, nous établissons, à l’aide de modèles analytiques et numériques, le dimensionnement optimal permettant de répondre simultanément aux spécifications dimensionnelles et au niveau de puissance récoltée nécessaire. Cette phase d’optimisation montre qu’un compromis entre fréquence de résonance et puissance délivrée doit être fait et, plus particulièrement, que celui-ci conduit à l’expression d’un besoin en termes d’épaisseur de couches piézoélectriques auquel aucune des technologies standards ne permet de répondre. Nous présentons, dans ce manuscrit, les travaux qui ont ainsi été menés pour développer une technique de réalisation de couches épaisses de PZT (typ. 15 à 100 µm) par amincissement de céramiques massives. Ce mode de réalisation est enfin mis en œuvre pour la fabrication d’un démonstrateur à l’échelle, de type poutre encastrée-libre bimorphe vibrant à 16 Hz. Nous montrons finalement que les résultats obtenus à partir de battements cardiaques reproduits en laboratoire (10-15 µW) sont en ligne avec les besoins exprimés pour la mise en œuvre d’une solution d’alimentation pour pacemaker sans fil. Ce travail de thèse a été conduit dans le cadre du projet HBS (Heart Beat Scavenging) notamment en collaboration avec la société LivaNova-Sorin CRM (Cardiac Rythm Management). Il est fortement probable que la décision initiale d’articuler l’ensemble de tâches accomplies autour des besoins de l’utilisateur final soit une des clés de la réussite de ce travail. En effet, les démonstrateurs développés dans ce travail de thèse ont, par la suite, été testés avec succès sur l’animal. Ils ont également donné lieu à un nouveau projet dont un des objectifs est d’adresser les aspects de fiabilité et de vieillissement. Ces nouvelles tâches correspondent ainsi à la poursuite de la montée en TRL (Technology Readiness Level) vers les étapes de pré-industrialisation. / The field of cardiac assistance is currently experiencing a new technological breakthrough with the introduction of the leadless pacemaker. With these new devices, the care of patients is simplified. Furthermore, removal of the leads should allow a drastic reduction of the problems encountered with conventional pacemakers. However, the question of the energy supply remains. In this thesis, we try to provide a solution based on piezoelectric inertial micro-generator in order to harvest a portion of the heartbeat vibrational energy. The approach is to first define the need and relevance of a solution based on energy scavenging. We then analyze the cardiac signals that were recorded using accelerometers positioned directly on the stimulation site. It is shown that the addressed vibration source (i.e. heartbeats) impose the devices to vibrate at around 16 Hz. These frequencies are extremely low compared to microgenerators presented in the literature (typ.> 100 Hz). Secondly, regardless of technological considerations, and using analytical and numerical models, we identify the optimal device dimensions in order to simultaneously meet the specifications in terms of size and required harvested power. This optimization phase shows that a trade-off between resonant frequency and output power must be made and, more particularly, that it leads to the expression of a need in terms of piezoelectric layer thickness to which none of the standard technologies can currently answer. Therefore, we present the work that has been undertaken to develop a technique for producing thick layers of PZT (typ. 15 to 100 µm) by the thinning and the polishing of bulk ceramics. Then, this technique is implemented for the fabrication of our demonstrator: a cantilever of bimorph type vibrating at 16 Hz. Finally, we show that the obtained results (10-15 µW) from heartbeats reproduced in the laboratory are in line with the expressed needs for the implementation of an energy supply solution for leadless pacemakers. This thesis work has been conducted in the frame of the HBS project (Heart Beat Scavenging) especially in collaboration with the company LivaNova - Sorin CRM (Cardiac Rhythm Management). It is highly believed that the original decision to articulate all the tasks that we performed around the end user needs was a key to the success of this work. Indeed, the demonstrators developed in this thesis have subsequently been successfully tested on animals. They also led to a new project whose objectives are to address the reliability and aging of these demonstrators. These new tasks correspond to the continuation of the TRL increase (Technology Readiness Level) to the stages of pre-industrialization.

Page generated in 0.1117 seconds