• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 6
  • 1
  • Tagged with
  • 19
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Micro et nano structuration de matériaux : application aux laboratoires sur puce et à l’imagerie médicale / Micro and nano structuration of materials : application to Lab-On-Chips and CT-scan Imaging

De Ville, Magalie 20 October 2014 (has links)
La conception et la fabrication « à façon » de dispositifs microfluidiques requiert très souvent l’utilisation de multiples équipements coûteux en temps et en argent (lithographie notamment). Par ailleurs, l’achat auprès de fournisseurs industriels ne permet pas toujours l’obtention de structures pleinement adaptées aux besoins de l’utilisateur final, notamment dans le contexte médical, où un niveau minimal de biocompatibilité est souhaitable. La première partie de notre étude porte donc sur le développement d’une technique de création personnalisée, rapide et à moindre frais de réseaux microfluidiques à section circulaire, en polydimethylsiloxane. Par suite, la thématique « Lab On Chip » est naturellement liée au développement de techniques de détection. L’imagerie médicale par agents de contraste est l’une de ces voies de détection. Les agents de contraste les plus utilisés sont les produits iodés, qui ne permettent pas toujours l’obtention d’un contraste optimal sur les clichés scanner. L’injection de ces produits peut engendrer de graves complications chez des patients potentiellement allergiques, d’autant plus qu’ils se dispersent dans la totalité de l’organisme. Ainsi le développement de nouveaux produits de contraste plus efficients, et qui pourraient permettre un ciblage biologique plus localisé est un challenge d’actualité. Dans ce but, la synthèse de particules d’or de formes et de tailles variées a été réalisée. Ces particules ont été analysées par imagerie micro-scanner pour petit animal, afin d’optimiser d’une part les protocoles sur équipement réel, et d’autre part vérifier les possibilités de discrimination des différents types d’échantillons, ainsi que le bénéfice engendré comparativement à des échantillons d’agents de contraste iodés. / Conception and fabrication of microfluidic devices is frequently money and time consuming. Furthermore, sophisticated equipments and techniques are required (eg. lithography). Moreover, industrial manufacturers do not provide perfectly adapted devices. Their structures do not completely match with final needs of their users, especially in medicine context, where a minimal level of biocompatibility is desirable. The first part of this study is dedicated to the development of a customizable technique. This method will enable quick and low cost creation of microfluidic networks made of polydimethylsiloxane, with circular channel section. Then, this Lab-On-Chip thematic can be linked to the development of detection techniques. Medical imaging is one of those ways of detection. The most used contrast agents are the iodinated ones, but they do not always give a good enough contrast on the scanner images. Moreover, injection of those iodinated products can produce medical complications as a deadly allergy for some sensitive patients, as they disperse everywhere in the body. Thus, development of new and more efficient contrast agents, able to target more precisely specific zones in the human body is a challenge. To reach this aim, the synthesis of gold micro and nanoparticles with different sizes and shapes have been realised. These particles have been analyzed using a micro-scanner equipment. Those analyses have enabled on the one hand the protocols optimization onto real medical equipment, and on the other hand, they have permitted to verify the possibilities of discrimination of the samples between themselves and the benefit given by the gold particles onto the iodinated samples.
2

Conception d'un appareil de mesure par spectroscopie et cartouches microfluidiques

Daignault Bouchard, Arthur 16 January 2024 (has links)
Titre de l'écran-titre (visionné le 5 janvier 2024) / La spectroscopie est largement utilisée en chimie analytique pour analyser différents échantillons. Quant à elles, la microfluidique et la microfabrication servent à exploiter les propriétés des fluides agissant à de très basses valeurs de Reynolds. L'intégration de la spectroscopie et de la microfluidique est un domaine relativement nouveau et peu exploré, mais une intégration fiable et de qualité montre énormément de potentiel pour la recherche comme les avantages de chaque méthode peuvent être combinés. Dans un premier temps, un accessoire de mesure spectroscopique conçu par un autre étudiant à la maitrise a été adapté et amélioré dans le but de le rendre plus fiable, plus précis et plus facilement fabricable à grande échelle. Contrairement aux outils disponibles sur le marché présentement, cet outil permet d'analyser plusieurs échantillons à la fois grâce à un système de déplacement dans deux axes. L'appareil s'adapte à différents spectromètres infrarouge à transformée de Fourier (FTIR) et se sert d'un cristal à réflectance totale atténuée (ATR) afin d'analyser différents échantillons. La version conçue dans le cadre de ce projet de maîtrise s'adapte à différentes cartouches microfluidiques également conçues dans le cadre de ce projet. Dans le cadre de ce projet de maîtrise, l'appareil conçu a été testé, adapté et modifié afin de mieux répondre aux besoins des utilisateurs. Ces besoins ont été définis de façon précise afin de bien pouvoir cibler quelles fonctions sont essentielles. Les cartouches microfluidiques ont été conçues et simulées à l'aide de logiciels d'analyse par éléments finis. Une fois fabriquées, elles ont été testées sur différents spectromètres afin de valider les performances ainsi que la qualité de l'intégration des cartouches dans l'accessoire. / Spectroscopy is widely used in analytical chemistry to analyze different samples. Microfluidics and microfabrication are used to exploit the properties of fluids acting at very low Reynolds. The integration of spectroscopy and microfluidics is a relatively new and unexplored area, but a reliable and high-quality integration shows great potential for research as the advantages of each method can be combined. First, a spectroscopic measurement accessory designed by another master's student is adapted and improved to make it more reliable, more accurate and more easily manufacturable on a large scale. Contrary to the tools available on the market today, this tool allows to analyze several samples at the same time thanks to a system of displacement in two axes. The instrument is adaptable to different Fourier transform infrared spectrometers (FTIR) and uses an attenuated total reflectance crystal (ATR) to analyze different samples. The version designed in this master's project is adaptable to different microfluidic cartridges also designed in this project. Within the framework of this master's project, the designed apparatus is tested, adapted and modified in order to better meet the needs. These needs have been precisely defined in order to target which functions are essential. The microfluidic cartridges were designed and simulated using finite element analysis software. Once manufactured, they were tested on different spectrometers to validate the performance as well as the quality of the integration of the cartridges in the device.
3

Optimisation des réacteurs microfluidiques microbiens en contrôlant la croissance et l'homogénéité du biofilm

Asayesh, Farnaz 24 April 2018 (has links)
Les biofilms microbiens soit des communautés multicellulaires formées de bactéries, adhérant à une surface, entourés d'une couche de polymère extracellulaire (EPS). Parce qu'ils sont naturels, les biofilms bactériens sont de plus en plus étudiés et utilisés pour des applications en biocatalyse, en autoréparation et en tant que systèmes pouvant fonctionner efficacement dans des conditions ambiantes. La structure du biofilm est également importante, car elle peut protéger les bactéries sous les contraintes physiques, chimiques et biologiques rencontrées lors de l'opération du bioréacteur. Parmi les principaux facteurs entrant dans la régulation du développement du biofilm et de ses propriétés à maturité, on trouve les conditions hydrodynamiques et les concentrations d'éléments nutritifs appliquées. La microfluidique connait une popularité croissante parmi la communauté de recherche sur les biofilms en raison de sa capacité à mieux contrôler ces paramètres en fonction de d'autres propriétés physicochimiques importantes et même le taux de croissance. Dans ce travail, nous nous appuyons sur les travaux antérieurs de notre groupe pour résoudre deux principales limites. Tout d'abord, la tendance des biofilms à contaminer les canaux et les tubes en amont peut éroder les spécifications précises des conditions expérimentales dans les positions en aval d'où des mesures analytiques sont réalisées. La premiere partie ce travail, nous présentons un dispositif microfluidique qui varie la vitesse d'écoulement en amont pour arrêter la croissance vers l'arrière et la contamination de l'entrée pour les expériences de longue durée. Le deuxième point d'intérêt est lié à des facteurs qui provoquent une hétérogénéité dans les modèles de croissance du biofilm. On a noté que les bulles formées pendant et après l'inoculation augmentaient la croissance locale du biofilm et réduisaient l'uniformité et l'homogénéité globale. Ce mémoire étudie également les effets des bulles sur le taux de croissance et le développement secondaire du biofilm.
4

Microfluidique de gouttes 2D par gradient de confinement

Dangla, Rémi 08 October 2012 (has links) (PDF)
L'usage de gouttes comme microréacteurs movite le développement rapide de la microfluidique de gouttes. En effet, une goutte peut être utilisée pour collecter, transporter et analyser du matériel chimique, biologique ou génétique. Ainsi, la microfluidique de goutte porte la promesse d'une miniaturisation et d'une automatisation sur puce des process actuellement mis oeuvre sur microplaques. Toutefois, l'architecture des dispositifs reste essentiellement sérielle et en opposition avec le format intrinsèquement 2D des microplaques. Ce travail de thèse fournit une nouvelle stratégie de gestion de gouttes sur puce qui permet d'implémenter des procédés de microfluidiques de goutte au sein de chambres bidimensionnelles. Les méthodes mises au point emploient des gradients de confinement pour agir sur les gouttes.
5

Gouttes, vésicules et globules rouges: Deformabilité et comportement sous écoulement

Faivre, Magalie 04 December 2006 (has links) (PDF)
Les gouttes, les vésicules et les globules rouges sont des objets mous et déformables, structurés et de taille micrométrique (de 1 à 100 microns de diamètre). L'objectif de ce travail est de déterminer la participation de chaque paramètre mécanique des objets étudiés (tension de surface, élasticité, viscosité...) à partir de leur comportement sous écoulement. Nous avons choisi de nous intéresser tout particulierement à la réponse de ces objets sous écoulement confiné (ou semi-confiné) en utilisant une approche de type « microfluidique ». <br />La production de tensio-actif à la surface d'une goutte en mouvement influence sa forme et sa dynamique. L'étude détaille notamment les effets de la concentration et de la géométrie.<br />La mise au point de vésicules aux propriétés complexes modulables par l'action de la température est exposée. Nous avons aussi étudié l'impact de la transition sol/gel de la membrane lipidique de vésicules DMPC sur leur comportement sous champs externes (pression osmotique, écoulement...). <br />Dans le cas des globules rouges soumis à un cisaillement, deux types de mouvements sont connus : un mouvement de bascule et un mouvement de chenille de char. Nous avons mis en évidence l'existence d'un nouveau régime d'oscillations superposé au mouvement de chenille de char. Notre étude a également porté sur le comportement de globules rouges s'écoulant dans des canaux de dimension comparable a leur taille. Un diagramme de forme a été établi en fonction de la vitesse de l'objet, de la viscosité externe et de la section du capillaire. Nous avons développé un système mesurant la chute de pression associée au passage d'une cellule unique dans un canal de même dimension. Cette mesure permet notament de corréler le signal obtenu avec les propriétés physiques et mécaniques des objets étudiés. Nous avons illustré cette approche avec des globules blancs et des globules rouges. Nous nous sommes enfin intéressés au cas d'une suspension concentrée de cellules sanguines dans un écoulement pathologique: la thrombose.
6

Fabrication, integration and study of micropillars for cell culture / Fabrication, intégration et étude de micropiliers pour la culture cellulaire

Wei, Jin 15 September 2017 (has links)
Ce travail a pour but de développer des nouveaux substrats d’étude en culture cellulaire. Nous avons d'abord fabriqué des réseaux de micro-piliers en élastomère et en polymères thermoplastiques. En particulier, nous avons réalisé des réseaux de micro-piliers adjacents et de différentes hauteurs, qui dépend de la rigidité de la surface de culture. Nos résultats ont montré que les cellules étaient sensibles à la hauteur des piliers lorsque la rigidité effective du substrat était similaire à celle de la cellule et que les cellules se déplacent préférentiellement vers la partie plus rigide. Nous avons également développé une méthode pour fabriquer des nanofibres sur les piliers élastomère pour créer un substrat qui reproduit la matrice extracellulaire in vivo. Nos résultats ont montré que les neurones primaires de l'hippocampe sur un tel substrat étaient plus actifs que sur des substrats plats. En outre, nous avons analysé le confinement et la déformation des noyaux cellulaires dans les espaces inter-piliers pour les études de cellules tumorales et de cellules souches. Enfin, nous avons intégré les réseaux de micro-piliers dans un dispositif microfluidique afin de montrer que la migration cellulaire soumise à un gradient de concentration était influencée par la rigidité du substrat. En conclusion, les micropiliers ainsi fabriqués peuvent être utilisés pour réguler la rigidité d’un substrat afin d’étudier divers mécanismes en culture cellulaire. / This work aimed to provide new substrates for cell culture studies. We first developed a method to fabricate micropillars in both elastomer and thermoplastic polymer. In particular, we produced adjacent micropillar arrays with different heights to evaluate the surface stiffness dependent migration of cells. Our results showed that cells were sensitive to the height of the pillars when the effective stiffness of the substrate is compatible to that of the cell and that the cells were preferentially localized on the stiffer surface area. We also developed a method to fabricate nanofibers on the elastomer pillars to create in-vivo like extracellular matrix. Our results showed that primary hippocampal neurons on such a substrate were more active than on flat substrates. Furthermore, we analyzed the confinement and deformation of cell nuclei in the inter-pillar areas for both cancer and stem cell studies. Finally, we integrated the micro-pillar arrays into a microfluidic device and showed that the cell migration under concentration gradient was influenced by the substrate stiffness. Altogether, the fabricated pillar arrays can be used to regulate the stiffness of the substrate for cell culture studies.
7

Caractérisation par imagerie en temps réel de cultures cellulaires hépatiques en biopuces microfluidiques / Characterization of liver cell culture in micro-fluidic biochips by a real time imaging analysis

Naudot, Marie 29 November 2013 (has links)
Le développement de méthodes alternatives à la culture in vivo pour l’évaluation de la toxicité des molécules chimiques s’est accéléré ces dernières années, l’objectif étant de limiter l’utilisation d’animaux. Préconisés par l’OCDE (Organisation de coopération et de développement économiques), ces modèles alternatifs visent à mimer les conditions physiologiques en employant des systèmes in vitro ou in silico. Parmi les différents systèmes développés, les biopuces microfluidiques ont prouvé leur contribution à l’amélioration des fonctions cellulaires, ce qui permet des études toxicologiques pertinentes. Les travaux de ce doctorat sont basés sur l’emploi de ces biopuces pour cultiver des hépatocytes (cellules du foie) et portent sur la mise au point d’une méthode d’analyse d’images issues de ces cultures sous microscope au cours du temps. L’acquisition d’images tout au long de l’expérience permet de suivre, après traitement, l’évolution et le comportement des cellules au contact de molécules chimiques et d’évaluer les réponses toxicologiques. Les premiers résultats de ces travaux ont permis l’amélioration du procédé de culture microfluidique adaptée au matériel d’acquisition d’images, la sélection de sondes fluorescentes, et le choix d’un algorithme de traitement des images sur CellProfiler. Cela nous a permis de quantifier et caractériser certaines fonctions biologiques au sein de la biopuce comme l’activité mitochondriale. Le potentiel de cet outil pour évaluer la toxicité de molécule a été testé grâce à l’emploi d’un toxique connu : la staurosporine. Les résultats obtenus ont révélé l’impact de la mise en culture en dynamique sur le comportement des hépatocytes, et la toxicité de la staurosporine visible en biopuce. / The development of alternative methods of in vivo cultures for the toxicological evaluation of chemical molecules has accelerated this last years, in order to limit the use of animals. Recommended by the OECD (Organisation for Economic Cooperation and Development), these alternative models are designed to mimic the physiological conditions using in vitro or in silico systems. Among the developed systems, microfluidic biochips have proven their contribution to the improvement of cellular functions, which allows relevant toxicological studies. This PhD thesis is based on the use of these biochips for hepatocytes culture and focus on the development of an analysis method for study these cultures under microscope over time using imaging. Image acquisition throughout the experiment enables to analyze, after image processing, the evolution and the behavior of cells in contact with chemical molecules and to evaluate toxicological responses. The first results of this work led to the optimization of the microfluidic cultures under the microscope used to get the image sequences, the selection of fluorescent probes and the development of an image processing system with CellProfiler. These works allowed the quantification and the characterization of some biological functions within the biochip such as the mitochondrial activity. Staurosporine, a well-known toxic, has been used to test the potential of this tool to evaluate the toxicity of molecules. The results showed the impact of dynamic culture on the hepatocytes behavior, and the staurosporine toxicity, in biochip cultures.
8

Développement de puces à ADN microfluidiques pour la détection de la résistance aux antibiotiques chez les bactéries à gram positif responsables des septicémies

Beauregard, Julie 19 April 2018 (has links)
Le phénomène de multirésistance aux antibiotiques chez les bactéries à Gram positif causant des infections sévères du sang est un problème mondial grandissant. La détection du niveau de sensibilité aux antibiotiques avec des tests phénotypiques requière un minimum de 48 h avant l'obtention des résultats. Il est donc nécessaire de développer des tests de diagnostic rapides, sensibles, spécifiques et ubiquitaires pour améliorer le traitement des septicémies. Ce mémoire de maîtrise présente le développement d'un test de diagnostic moléculaire permettant la détection rapide des gènes de résistance aux antibiotiques cliniquement importants associés aux bactéries à Gram positif causant des septicémies. Ce test comprend 4 essais PCR multiplex combinés à une hybridation microfluidique sur puces à ADN intégrées à un disque compact. Les corrélations obtenues entre les résultats génotypiques et phénotypiques étaient de 98% pour les P-lactamines et de 100% pour la vancomycine, la clindamycine et la gentamicine. Cette approche moléculaire pourrait éventuellement être utilisée pour le diagnostic clinique afin de guider l'antibiothérapie des patients atteints d'une septicémie.
9

Analyse et conception d'une micropompe pour des applications à très faible pression

Landari, Hamza 24 April 2018 (has links)
Dans ce mémoire, nous présentons une nouvelle architecture d’une micropompe pneumatique à valves autoactionnées. Une modélisation par éléments finis de la micropompe est également présentée ainsi que sa fabrication et sa caractérisation. Le débit théorique minimal de la micropompe est de 9 µL/min pour une pression externe d’actionnement égale à 1500 Pa. La fréquence de déformation imposée à la membrane est de 1,25 Hz et la déformation maximale observée de cette dernière est égale à 3,66 µm. On note aussi que la modélisation par la méthode des éléments finis montre clairement une conservation de débit entre les phases d’admission et de refoulement égal à 99,99 %, cette conservation de débit a été validée aussi expérimentalement. La fabrication de la micropompe s’est faite à travers deux procédures : un moulage manuel pour les microvalves avec des chambres cylindrique et cubiques dont les dimensions externes sont de 8 mm x 12 mm x 6 mm avec des membranes de 20 µm d’épaisseur, fabriquées en Polydimethylsiloxane (PDMS). Un nouveau procédé d’impression à base de sucre, en collaboration avec le département de mécanique, a été aussi utilisé. Ce dernier se résume dans l’impression 3D d’un moule temporaire en sucre vitrifié. Les chambres d’actionnement de la micropompe sont de forme cylindrique avec un diamètre de 4 mm et une hauteur de 1 mm. La chambre de pompage est aussi cylindrique avec le même diamètre, mais avec une hauteur 0,5 mm. L’épaisseur des membranes de pompage est de 250 μm. En utilisant ce procédé, tout le système de pompage excluant les microvalves est fabriqué en un seul bloc afin d’éliminer toute fuite et minimiser l’encombrement du système. Les dimensions externes de la micropompe sont 20 mm x 20 mm x 10 mm. Les résultats de caractérisation de la micropompe consistent le débit minimal qu’on a pu générer qui est égale à 7 µL/min avec une puissance électrique consommée par le système de 114 mW. Enfin, les microvalves peuvent supporter une contre-pression jusqu’à 13 psi. Une interface graphique pour contrôler l’actionneur de la micropompe à l’aide d’un FPGA a aussi été développée. / In this project, a new architecture of an air-driven micropump prototype with self-actuating microvalves is presented. A finite element model is also presented. Fabrication and characterization of the system and the electronic control of the micro-pump was also introduced. The designed micropump was able to generate a flow rate of 9 µL/min. Pumping pressure was 1500 Pa. Frequency of membrane deformation was 1.25 Hz and its maximum deformation was 3.66 µm. Finite element modeling shows that the flow rate ratio between the admission and delivery phase was 99.99 %. Fabrication of the micropump was achieved through two processes. First, a manual molding for microvalves with cylindrical and cubic chambers whose external dimensions was 8 mm x 12 mm x 6 mm and actuation membrane thickness of 20 µm. The entire system, including the membrane, was made from polydimethylsiloxane (PDMS). Second, in collaboration with the department of mechanical engineering, a new printing process based on sugar glass was also used. The latter is based on the 3D printing of a sugar mold. The mold is dissolved after the pouring and curing of PDMS. The actuating chambers of the micropump wetre cylindrical with a diameter of 4 mm and a height of 1 mm. The pumping chamber was also cylindrical with the same diameter but with a height of 0.5 mm. The thickness of the pumping membranes was 250 µm. Through this process, the entire pumping system (expect microvalves) were fabricated as a one block to eliminate leakage and reduce system dimensions. The external dimensions of the micropump was 20 mm x 20 mm x 10 mm. Experimental results of the micro-pump showed that the flow rate that can be generated is 7 µL/min. The electrical power consumption of the system was 114 mW. Finally, the microvalve can resist to a back pressure up to 13 psi. A graphical interface to control the actuation part of the micropump using an FPGA has also been developed.
10

Linear scanning ATR-FTIR for mapping and high throughput studies of bacterial biofilms in microfluidic channels

Pousti, Mohammad 08 November 2019 (has links)
Le domaine de la chimie bioanalytique est en plein développement. Les tendances vers une caractérisation plus précise, une analyse à haut débit et une automatisation accrue offrent la promesse de systèmes capables de fournir des informations plus détaillées sur les systèmes biologiques vivants. Les biofilms sont répandus dans la plupart des écosystèmes. Ils peuvent être formés par la plupart des microorganismes. Les biofilms microbiens sont des communautés multicellulaires de bactéries, adhérant à une surface, entourées d'une substance polymère extracellulaire (EPM). En raison de leur origine naturelle, les biofilms bactériens sont de plus en plus étudiés et utilisés pour des applications en biocatalyse, en auto-guérison et en tant que systèmes pouvant fonctionner efficacement dans des conditions ambiantes. Les principaux facteurs qui contrôlent le développement du biofilm et ses propriétés matures sont les conditions hydrodynamiques appliquées et les concentrations en éléments nutritifs. Les propriétés mécaniques du système EPM peuvent être personnalisées en fonction de son environnement. De plus, l’existence de différents groupes chimiques fonctionnels dans le biofilm permet de piéger des molécules organiques et des ions dissous. Cette thèse porte sur le développement d'une technique permettant une flexibilité et une précision dans la croissance et la détection des biofilms de Pseudomonas sp. Bactérie CT07. Le système analytique est multimodal afin d’obtenir des informations sur les propriétés chimiques et structurelles du biofilm. À cette fin, la microscopie optique et la spectroscopie infrarouge à transformée de Fourier (FTIR) à réflexion totale atténuée (ATR) ont été couplées dans un système analytique coordonné avec des canaux microfluidiques pour contrôler les conditions de croissance des biofilms. Pour atteindre cet objectif, un montage ATR-IR fait maison a été développé pour permettre de sonder différents emplacements au-dessus du cristal d'ATR afin d'ajouter une capacité de mesure au système situé à différents emplacements. Les différentes méthodologies développées dans cette thèse peuvent être appliquées à d'autres systèmes complexes à l'avenir. La combinaison de la microfluidique pour un contrôle de flux précis ainsi que des mesures multiplexées dans un microcanal parallèle est la clé pour obtenir des indices importants et statistiquement pertinents sur la croissance des biofilms et sur les méthodes pour les contrôler. / The field of bioanalytical chemistry is currently undergoing rapid development. Trends toward more precise characterization, high-throughput analysis and greater levels of automation collectively offer the promise of systems that can deliver deeper insights into living biological systems. Biofilms are widespread in most ecosystems. They can be formed by most microorganisms. Microbial biofilms are multicellular communities of bacteria, adhering to a surface, surrounded by an extracellular polymeric matrix (EPM). Because they are natural, bacterial biofilms are increasingly being studied and used for applications in biocatalysis, self-healing and as systems that can function effectively under ambient conditions. The main factors controlling biofilm development and its mature properties are the applied hydrodynamic conditions and nutrient concentrations. The mechanical properties of the EPM can be customized based on its environment. Additionally, the existence of different functional chemical groups within biofilm makes it possible to trap organic molecules and dissolved ions. This PhD thesis focus on developing a system-level technique that enables flexibility and precision in the growth and detection of biofilms from Pseudomonas sp. CT07 bacteria. The analytical system is multi-modal, in order to obtain information on biofilm chemical and structure properties. To this end, optical microscopy and attenuated total reflection (ATR) Fourier transform infrared (FTIR) spectroscopy have been coupled into one coordinated analytical system with microfluidic channels to control the growth conditions of biofilms. To achieve this goal, a home-built ATR-FTIR stage was developed for probing different locations on top of ATR crystal. The methodologies developed in this thesis can be applied to other complex analytical systems in the future. The combination of microfluidics for precise flow control as well as multiplexed measurements in parallel microchannel is the key to obtaining important and statistically relevant clues to the growth of biofilms and the methods to control them.

Page generated in 0.1038 seconds