• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 16
  • 12
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Adequação da qualidade microbiológica de efluentes de tratamento secundário de esgoto sanitário pela aplicação dos desinfetantes ozônio, permanganato de potássio e ácido peracético / Microbiological quality adequation of the wastewater secondary effluent by the application of ozone, potassium permanganate and peracetic acid desinfectants

Sartori, Luci 10 December 2004 (has links)
Esta pesquisa abordou a influência do ozônio, ácido peracético e permanganato de potássio na inativação dos microrganismos indicadores E.coli, colifago, C.perfringens e Ascaris lumbricoides de efluentes secundários, visando reúso em agricultura. Os efluentes utilizados para os ensaios com ozônio foram provenientes da Estação de Tratamento de Esgoto da cidade de Lins-SP (o tratamento consiste em lagoa anaeróbia seguida de facultativa) e da Estação de Tratamento de Esgoto da cidade de Araraquara-SP, na qual o tratamento é constituído de lagoa aerada seguida de lagoa de sedimentação. Para os ensaios de desinfecção com ácido peracético e permanganato de potássio utilizou-se apenas o efluente da Estação de Tratamento de Esgoto da cidade de Araraquara-SP. Os ensaios de desinfecção demonstraram que o ácido peracético tem maior poder bactericida em relação ao ozônio e permanganato de potássio. O ozônio foi mais eficiente na inativação do microrganismo colifago. Para todos os desinfetantes usados, a concentração da bactéria esporulada C.perfringens permaneceu entre 103 a 104 NMP/100 mL. Todos os desinfetantes, nas concentrações e tempos de contatos testados, mostraram-se tóxicos nas primeiras 24 h ao microcrustáceo Daphnia similis. O desinfetante que alcançou, com menor concentração e tempo de contato, o padrão proposto pela OMS (1989) para irrigação irrestrita foi o ácido peracético com 5 mg/L e tempo de contato de 10 minutos. Já a concentração de ozônio consumida de 40 mg/L e tempo de contato de 10 minutos foram suficientes para atender ao padrão proposto para irrigação restrita. / This research deals with the influence of ozone, peracetic acid and potassium permanganate on the inactivation of indicator microorganisms E.coli, coliphage, Clostridium perfringens and Ascaris lumbricoides secondary effluents, aiming agricultural reuse. The effluents used for the analyses with ozone had been proceeding from the Lins-SP Wastewater Treatment Plant (the treatment consists of an anaerobic lagoon followed by a facultative one) and from the Araraquara-SP Wastewater Treatment Plant, where the treatment consists of an aerated lagoon followed by a sedimentation pond. For the disinfection analyses with peracetic acid and potassium permanganate only the effluent from the Araraquara-SP Wastewater Treatment Plant was used. The disinfection analyses demonstrated that the peracetic acid has greater bactericide power than ozone and potassium permanganate. Ozone was more efficient in the coliphage microorganism inactivation. For all used disinfectants the concentration of sporulated bacteria Clostridium perfringens remained between 103 and 104 NPM/100 mL. All the disinfectants, under the concentration and contact time tested, showed themselves toxic during the first 24 h, and did not show any mortality to the Daphnia similis microorganism after that period. The disinfectant that reached, under lower concentration and contact time, the proposed standard for unrestricted irrigation from WHO (1989) was the peracetic acid with 5 mg/L and contact time of 10 minutes.
2

Aplicação de radiação UV para desinfecção de efluente da associação de reator UASB e biofiltro aerado submerso / UV radiation application for sewer disinfection of the UASB reactor association with aerated submerged biofilter (ASB)

Silva, Silvia Sônia da 20 September 2007 (has links)
Essa pesquisa investigou e interpretou aspectos relevantes da desinfecção por radiação ultravioleta (UV) na inativação de microrganismos indicadores. O efluente sanitário foi proveniente de tratamento anaeróbio (Reator UASB), seguido de Biofiltro Aerado Submerso, em escala real. A pesquisa foi dividida em duas etapas, sendo que na primeira foi dado destaque ao estudo das características operacionais da unidade ultravioleta. Na segunda etapa da pesquisa objetivou-se o estudo da resistência de diferentes microrganismos indicadores à radiação ultravioleta e das possíveis correlações entre as variáveis testadas. Os resultados obtidos na primeira etapa da pesquisa forneceram indicativos de que a limpeza das lâmpadas emersas pode ser feita em períodos superiores a 2 meses, devendo-se levar em consideração também a fragilidade do sistema. A limpeza do canal de desinfecção não teve relação com a eficiência de desinfecção. A operação de unidades UV é relativamente simples desde que haja treinamento dos operadores e condições ergonômicas favoráveis ao trabalho dos mesmos. O custo operacional situou-se na faixa de 0,006 R$/\'M POT.3\' de esgoto desinfetado e o custo de energia elétrica foi de 0,07 R$/\'M POT.3\' de esgoto desinfetado. As eficiências máximas de desinfecção encontradas na segunda etapa da pesquisa foram de 100% para Colifagos, 99,999% para CF (Coliformes Fecais) e 99,993% para CT (Coliformes Totais), o que demonstra que a ordem decrescente de resistência desses organismos é CT > CF > Colifagos. Os resultados indicaram que houve pouca variação da eficiência de inativação para as três lâminas de esgoto testadas (3 cm, 4 cm e 5 cm) o que sugere que a unidade é capaz de atender aumentos moderados de vazão, confirmando os pressupostos adotados no seu dimensionamento. Os dados obtidos a partir do ensaio hidrodinâmico indicaram que o reator de desinfecção testado comporta-se como um sistema composto de um reator pistonado ideal com presença de curtos circuitos hidráulicos. / This research has investigated and interpreted relevant aspects of disinfection by ultraviolet radiation (UVR) in the inativation of indicator microorganisms\' inactivation. The sanitary effluent was provided by anaerobic treatment (UASB reactor), followed by aerated submerged biofilter (ASB), on a real scale. This research was divided into two stages, whereas in the first stage, operational characteristics of the ultraviolet unit studies were highlighted. The aim of the second stage of the research was the resistance of different indicator microorganisms to ultraviolet radiation study and the possible relation among variables tested. Results obtained in the first stage of the research have provided indication that the cleaning of submerged lamps may be done in periods longer than two months, however the fragility of the system must be considered. Disinfection channel cleaning should not be related to the disinfection efficiency. The operation of UV units is relatively simple, as long as the operators are trained and work under favorable ergonomic conditions. The operational cost was set at 0.006 R$/\'M POT.3\' of disinfected sewer system and the electrical energy cost was set at 0.07 R$/\'M POT.3\'. The maximum efficiency found on the disinfection of the research second stage were 100% for Coliphages, 99.999% for FC and 99.993% for TC, which demonstrates that the resistance decreasing order of these organisms is TC > FC > Coliphages. Results indicated that there was a low inactivation efficiency variation for the three tested sewer samples (3 cm, 4 cm and 5 cm), which suggests that the unit is capable of serving moderate increase of flow, confirming adopted predictions in its dimensioning. Information obtained from the hydrodynamic test indicated that the tested disinfection reactor behaves as a compound system of an ideal piston reactor with hydraulic short circuits.
3

Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection process

Souza, Jeanette Beber de 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested
4

Aplicação de radiação UV para desinfecção de efluente da associação de reator UASB e biofiltro aerado submerso / UV radiation application for sewer disinfection of the UASB reactor association with aerated submerged biofilter (ASB)

Silvia Sônia da Silva 20 September 2007 (has links)
Essa pesquisa investigou e interpretou aspectos relevantes da desinfecção por radiação ultravioleta (UV) na inativação de microrganismos indicadores. O efluente sanitário foi proveniente de tratamento anaeróbio (Reator UASB), seguido de Biofiltro Aerado Submerso, em escala real. A pesquisa foi dividida em duas etapas, sendo que na primeira foi dado destaque ao estudo das características operacionais da unidade ultravioleta. Na segunda etapa da pesquisa objetivou-se o estudo da resistência de diferentes microrganismos indicadores à radiação ultravioleta e das possíveis correlações entre as variáveis testadas. Os resultados obtidos na primeira etapa da pesquisa forneceram indicativos de que a limpeza das lâmpadas emersas pode ser feita em períodos superiores a 2 meses, devendo-se levar em consideração também a fragilidade do sistema. A limpeza do canal de desinfecção não teve relação com a eficiência de desinfecção. A operação de unidades UV é relativamente simples desde que haja treinamento dos operadores e condições ergonômicas favoráveis ao trabalho dos mesmos. O custo operacional situou-se na faixa de 0,006 R$/\'M POT.3\' de esgoto desinfetado e o custo de energia elétrica foi de 0,07 R$/\'M POT.3\' de esgoto desinfetado. As eficiências máximas de desinfecção encontradas na segunda etapa da pesquisa foram de 100% para Colifagos, 99,999% para CF (Coliformes Fecais) e 99,993% para CT (Coliformes Totais), o que demonstra que a ordem decrescente de resistência desses organismos é CT > CF > Colifagos. Os resultados indicaram que houve pouca variação da eficiência de inativação para as três lâminas de esgoto testadas (3 cm, 4 cm e 5 cm) o que sugere que a unidade é capaz de atender aumentos moderados de vazão, confirmando os pressupostos adotados no seu dimensionamento. Os dados obtidos a partir do ensaio hidrodinâmico indicaram que o reator de desinfecção testado comporta-se como um sistema composto de um reator pistonado ideal com presença de curtos circuitos hidráulicos. / This research has investigated and interpreted relevant aspects of disinfection by ultraviolet radiation (UVR) in the inativation of indicator microorganisms\' inactivation. The sanitary effluent was provided by anaerobic treatment (UASB reactor), followed by aerated submerged biofilter (ASB), on a real scale. This research was divided into two stages, whereas in the first stage, operational characteristics of the ultraviolet unit studies were highlighted. The aim of the second stage of the research was the resistance of different indicator microorganisms to ultraviolet radiation study and the possible relation among variables tested. Results obtained in the first stage of the research have provided indication that the cleaning of submerged lamps may be done in periods longer than two months, however the fragility of the system must be considered. Disinfection channel cleaning should not be related to the disinfection efficiency. The operation of UV units is relatively simple, as long as the operators are trained and work under favorable ergonomic conditions. The operational cost was set at 0.006 R$/\'M POT.3\' of disinfected sewer system and the electrical energy cost was set at 0.07 R$/\'M POT.3\'. The maximum efficiency found on the disinfection of the research second stage were 100% for Coliphages, 99.999% for FC and 99.993% for TC, which demonstrates that the resistance decreasing order of these organisms is TC > FC > Coliphages. Results indicated that there was a low inactivation efficiency variation for the three tested sewer samples (3 cm, 4 cm and 5 cm), which suggests that the unit is capable of serving moderate increase of flow, confirming adopted predictions in its dimensioning. Information obtained from the hydrodynamic test indicated that the tested disinfection reactor behaves as a compound system of an ideal piston reactor with hydraulic short circuits.
5

Ozonização de esgoto sanitário: estudo da hidrodinâmica, transferência de massa e inativação de microrganismos indicadores / Domestic sanitary sewer: study of hydrodynamics, mass transfer and microrganisms indicator inativation

Soares, Leonardo Vieira 27 September 2007 (has links)
Esta pesquisa teve como objetivo estudar a hidrodinâmica, a transferência de massa e a inativação de microrganismos indicadores durante o processo de ozonização de esgoto sanitário tratado previamente em reator UASB. A pesquisa foi dividida em três grupos de ensaios, experimentos I, II e III, nos quais foram medidas as concentrações de bolhas de ozônio, os campos de velocidades instantâneos e médios, os diâmetros das bolhas de ozônio e realizados ensaios de desinfecção com ozônio para inativação de microrganismos indicadores - E. coli, colifagos e Clostridium perfringens - e remoção de DQO. Estes ensaios foram realizados tanto em batelada (experimento I e II) quanto em fluxo contínuo (experimento III), e as dosagens de ozônio aplicado foram de 10 e 20 mg/L e os tempos de contato de 5, 10, 15 e 20 minutos. As concentrações, velocidades e diâmetros das bolhas de ozônio foram proporcionais às vazões de ozônio aplicadas e variaram, respectivamente, de 0,23 a 5,26%, de 6,84 a 10,81 cm/s e de 0,260 a 1,781 mm. A quantidade de ozônio consumido variou entre 50,5% e 99,3%, em relação à dose de ozônio aplicado, e seu valor foi decrescente com o aumento da vazão de ozônio. Quanto à inativação dos microrganismos indicadores, C. perfringens apresentou-se como o mais resistente à ação bactericida do ozônio seguido por E. coli e colifagos. Foram inativados 1,7 log de C. perfringens (Ct = 80 mg.min/L); 6,1 log de E. coli (Ct = 133 mg.min/L); e 100% de colifagos (Ct = 38 mg.min/L). O controle das características de ensaios - dose e vazão aplicadas e tempo de contato -, bem como das características hidrodinâmicas das bolhas de ozônio podem otimizar o processo de ozonização de esgoto sanitário tornando-o atrativo técnica e economicamente. / This research had as objective study hydrodynamics, mass transfer and indicating microrganisms inativation during the ozonization process of sanitary sewer treated previously in UASB reactor. The research was divided in three groups of assays, experiment I, II e III, in which had been measured the concentrations, velocity and diameter of bubbles and carried through assays of disinfection with ozone for indicating microrganisms inativation - E. coli, coliphages and C. perfringens - and COD removal. These assays had been carried through in batch (experiment I and II) how much in continuous flow (experiment III), and the dosages of applied ozone had been of 10 and 20 mg/L and the times of contact of 5, 10, 15 and 20 minutes. The concentrations, velocity and diameters of ozone bubbles had been proportional to the applied ozone outflows and had varied, respectively, of 0,23 to 5,26%, of 6,84 to 10,81 cm/s and 0,26 to 1,781 mm. The amount of consumed ozone varied between 50,5 and 99,3%, in relation to the dosage of applied ozone, and its value was decreasing with the increase of the ozone outflow. For the indicating microorganisms inativation, C. perfringens was presented as most resistant to the bactericidal action of ozone followed for E. coli and coliphages. Had been inactivated 1,7 log of C. perfringens (Ct = 80 mg.min/L); 6,1 log of E coli (Ct = 133 mg.min/L); and 100% of colifphages (Ct = 38 mg.min/L). The control of the characteristics of assays - dosage and outflow applied and time of contact -, as well as of the hydrodynamic characteristics of the ozone bubbles they can optimize the ozonization process of sanitary sewer becoming it attractive technique and economically.
6

Ozonização de esgoto sanitário: estudo da hidrodinâmica, transferência de massa e inativação de microrganismos indicadores / Domestic sanitary sewer: study of hydrodynamics, mass transfer and microrganisms indicator inativation

Leonardo Vieira Soares 27 September 2007 (has links)
Esta pesquisa teve como objetivo estudar a hidrodinâmica, a transferência de massa e a inativação de microrganismos indicadores durante o processo de ozonização de esgoto sanitário tratado previamente em reator UASB. A pesquisa foi dividida em três grupos de ensaios, experimentos I, II e III, nos quais foram medidas as concentrações de bolhas de ozônio, os campos de velocidades instantâneos e médios, os diâmetros das bolhas de ozônio e realizados ensaios de desinfecção com ozônio para inativação de microrganismos indicadores - E. coli, colifagos e Clostridium perfringens - e remoção de DQO. Estes ensaios foram realizados tanto em batelada (experimento I e II) quanto em fluxo contínuo (experimento III), e as dosagens de ozônio aplicado foram de 10 e 20 mg/L e os tempos de contato de 5, 10, 15 e 20 minutos. As concentrações, velocidades e diâmetros das bolhas de ozônio foram proporcionais às vazões de ozônio aplicadas e variaram, respectivamente, de 0,23 a 5,26%, de 6,84 a 10,81 cm/s e de 0,260 a 1,781 mm. A quantidade de ozônio consumido variou entre 50,5% e 99,3%, em relação à dose de ozônio aplicado, e seu valor foi decrescente com o aumento da vazão de ozônio. Quanto à inativação dos microrganismos indicadores, C. perfringens apresentou-se como o mais resistente à ação bactericida do ozônio seguido por E. coli e colifagos. Foram inativados 1,7 log de C. perfringens (Ct = 80 mg.min/L); 6,1 log de E. coli (Ct = 133 mg.min/L); e 100% de colifagos (Ct = 38 mg.min/L). O controle das características de ensaios - dose e vazão aplicadas e tempo de contato -, bem como das características hidrodinâmicas das bolhas de ozônio podem otimizar o processo de ozonização de esgoto sanitário tornando-o atrativo técnica e economicamente. / This research had as objective study hydrodynamics, mass transfer and indicating microrganisms inativation during the ozonization process of sanitary sewer treated previously in UASB reactor. The research was divided in three groups of assays, experiment I, II e III, in which had been measured the concentrations, velocity and diameter of bubbles and carried through assays of disinfection with ozone for indicating microrganisms inativation - E. coli, coliphages and C. perfringens - and COD removal. These assays had been carried through in batch (experiment I and II) how much in continuous flow (experiment III), and the dosages of applied ozone had been of 10 and 20 mg/L and the times of contact of 5, 10, 15 and 20 minutes. The concentrations, velocity and diameters of ozone bubbles had been proportional to the applied ozone outflows and had varied, respectively, of 0,23 to 5,26%, of 6,84 to 10,81 cm/s and 0,26 to 1,781 mm. The amount of consumed ozone varied between 50,5 and 99,3%, in relation to the dosage of applied ozone, and its value was decreasing with the increase of the ozone outflow. For the indicating microorganisms inativation, C. perfringens was presented as most resistant to the bactericidal action of ozone followed for E. coli and coliphages. Had been inactivated 1,7 log of C. perfringens (Ct = 80 mg.min/L); 6,1 log of E coli (Ct = 133 mg.min/L); and 100% of colifphages (Ct = 38 mg.min/L). The control of the characteristics of assays - dosage and outflow applied and time of contact -, as well as of the hydrodynamic characteristics of the ozone bubbles they can optimize the ozonization process of sanitary sewer becoming it attractive technique and economically.
7

Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection process

Jeanette Beber de Souza 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested
8

Adequação da qualidade microbiológica de efluentes de tratamento secundário de esgoto sanitário pela aplicação dos desinfetantes ozônio, permanganato de potássio e ácido peracético / Microbiological quality adequation of the wastewater secondary effluent by the application of ozone, potassium permanganate and peracetic acid desinfectants

Luci Sartori 10 December 2004 (has links)
Esta pesquisa abordou a influência do ozônio, ácido peracético e permanganato de potássio na inativação dos microrganismos indicadores E.coli, colifago, C.perfringens e Ascaris lumbricoides de efluentes secundários, visando reúso em agricultura. Os efluentes utilizados para os ensaios com ozônio foram provenientes da Estação de Tratamento de Esgoto da cidade de Lins-SP (o tratamento consiste em lagoa anaeróbia seguida de facultativa) e da Estação de Tratamento de Esgoto da cidade de Araraquara-SP, na qual o tratamento é constituído de lagoa aerada seguida de lagoa de sedimentação. Para os ensaios de desinfecção com ácido peracético e permanganato de potássio utilizou-se apenas o efluente da Estação de Tratamento de Esgoto da cidade de Araraquara-SP. Os ensaios de desinfecção demonstraram que o ácido peracético tem maior poder bactericida em relação ao ozônio e permanganato de potássio. O ozônio foi mais eficiente na inativação do microrganismo colifago. Para todos os desinfetantes usados, a concentração da bactéria esporulada C.perfringens permaneceu entre 103 a 104 NMP/100 mL. Todos os desinfetantes, nas concentrações e tempos de contatos testados, mostraram-se tóxicos nas primeiras 24 h ao microcrustáceo Daphnia similis. O desinfetante que alcançou, com menor concentração e tempo de contato, o padrão proposto pela OMS (1989) para irrigação irrestrita foi o ácido peracético com 5 mg/L e tempo de contato de 10 minutos. Já a concentração de ozônio consumida de 40 mg/L e tempo de contato de 10 minutos foram suficientes para atender ao padrão proposto para irrigação restrita. / This research deals with the influence of ozone, peracetic acid and potassium permanganate on the inactivation of indicator microorganisms E.coli, coliphage, Clostridium perfringens and Ascaris lumbricoides secondary effluents, aiming agricultural reuse. The effluents used for the analyses with ozone had been proceeding from the Lins-SP Wastewater Treatment Plant (the treatment consists of an anaerobic lagoon followed by a facultative one) and from the Araraquara-SP Wastewater Treatment Plant, where the treatment consists of an aerated lagoon followed by a sedimentation pond. For the disinfection analyses with peracetic acid and potassium permanganate only the effluent from the Araraquara-SP Wastewater Treatment Plant was used. The disinfection analyses demonstrated that the peracetic acid has greater bactericide power than ozone and potassium permanganate. Ozone was more efficient in the coliphage microorganism inactivation. For all used disinfectants the concentration of sporulated bacteria Clostridium perfringens remained between 103 and 104 NPM/100 mL. All the disinfectants, under the concentration and contact time tested, showed themselves toxic during the first 24 h, and did not show any mortality to the Daphnia similis microorganism after that period. The disinfectant that reached, under lower concentration and contact time, the proposed standard for unrestricted irrigation from WHO (1989) was the peracetic acid with 5 mg/L and contact time of 10 minutes.
9

Inativação de microrganismos indicadores presentes em efluentes secundários de esgoto sanitário com radiação ultravioleta / Inactivation of indicator microorganisms presents in secondary effluents of wastewater with ultraviolet radiation

Coletti, Fábio José 16 May 2003 (has links)
Nesta pesquisa estudou-se o emprego de radiação ultravioleta em reatores de batelada e em reator com escoamento contínuo (unidade comercial de alta intensidade), respectivamente em escala de laboratório e real. Os ensaios em batelada tiveram como finalidade monitoramento da potência radiante da lâmpada de baixa pressão de vapor de mercúrio durante a vida útil, determinação da intensidade média de radiação ultravioleta incidente no interior da câmara de desinfecção, obtenção dos coeficientes do modelo de Hom para coliformes totais, Escherichia coli e Clostridium perfringens e comparação da resistência à desinfecção desses microrganismos indicadores e colifagos. Os ensaios em sistema contínuo apresentaram como principal objetivo estudo da resistência dos microrganismos indicadores à desinfecção em condições de operação em escala real. Nos ensaios de desinfecção utilizou-se esgoto sanitário tratado em nível secundário. Os microrganismos indicadores apresentaram a seguinte ordem decrescente de resistência à desinfecção: C. perfringens, coliformes totais, E. coli e colifagos. As percentagens de inativação de C. perfringens, coliformes totais, E. coli e colifagos nos ensaios em batelada variaram de 0 a 99,882%, 36,3 a 99,999%, 21,8 a 100% e de 86,5 a 100%, respectivamente. Os resultados de inativação obtidos para coliformes totais e E. coli apresentaram ajustes pelo modelo de Hom com valores de R2 superiores a 0,81 e 0,76, respectivamente. Comprovou-se que a instalação contínua é inadequada para efluentes com elevadas concentrações de sólidos em suspensão e matéria orgânica. / In this research the use of ultraviolet radiation was studied in batch and continuous flow (high intensity commercial unit) reactors, respectively in laboratory and real scale. The batch assays were aimed to monitor the wattage of the low-pressure mercury lamp during its lifetime, to determine the mean ultraviolet radiation intensity inside disinfection chamber, to obtain Hom model coefficients for total coliforms, Escherichia coli and Clostridium perfringens and to compare the resistance to disinfection of these indicator microorganisms and coliphages. The assays in the continuous system presented as main objective to study the resistance of these indicator microorganisms to disinfection in real scale operational conditions. In the disinfection assays wastewater treated by a secondary level was used. The indicator microorganisms presented the following decreasing order of disinfection resistance: C. perfringens, total coliforms, E. coli and coliphages. C. perfringens, total coliforms, E. coli and coliphages inactivation percentages in batch assays varied from 0 to 99,882%, 36,3 to 99,999%, 21,8 to 100% and from 86,5 to 100%, respectively. The inactivation results obtained for total coliforms and E. coli presented adjustments by Hom model with R2 values above 0,81 and 0,76, respectively. It was proved that the installation of high intensity is not adequate for effluents with high concentration of suspended solids and organic matter.
10

Processo de tratamento biológico e físico-químico combinados visando o reúso de esgoto sanitário / Biological treatment process and physical-chemical combinations aiming reuse sewage

Oliveira, Gabriela Laila de 01 June 2012 (has links)
Este trabalho teve por objetivo avaliar a combinação de processos de tratamento de esgoto e a partir dos efluentes produzidos com diferentes padrões de qualidade elencar as possibilidades para reúso de acordo com legislação internacional. Foi feito o monitoramento da estação piloto de tratamento de esgoto constituído reator UASB seguido de lodo ativado cujos efluentes foram utilizados neste estudo, não somente para análises físico-químicas e microbiológicas, mas também para posterior tratamento físico-químico em laboratório com equipamento jarteste utilizando dois coagulantes - cloreto férrico e sulfato de alumínio. Após os tratamentos combinados seis amostras diferentes foram analisadas, sendo elas: efluente do UASB, efluente do lodo ativado, tratamentos UASB-\'AL IND.2\'(\'SO IND.4\')IND.3\', UASB-\'FE\'CL IND.3\', lodo ativado-\'AL IND.2\'(\'SO IND.4\')IND.3\' e lodo ativado-\'FE\'CL IND.3\'. Os ensaios realizados com cloreto férrico foram os que melhor promoveram remoção dos microrganismos indicadores e de (oo)cistos, de DQO e SST. Porém, mesmo após o tratamento físico-químico não será possível reutilização agrícola, urbana e/ou industrial dos efluentes, conforme legislação internacional e diretrizes da OMS, uma vez que a concentração de microrganismos indicadores ainda é muito elevada. Os valores médios de E. coli, coliformes totais e Giardia spp., mesmo após o tratamento que forneceu melhor remoção microbiológica (lodo ativado \'FE\'CL IND.3\') foram de 4,31 x \'10 POT.2\', 7,68 x \'10 POT.3\' e 2,17 x \'10 POT.2\', respectivamente. / The present dissertation reports to evaluate the combination of process wastewater treatment and from the effluent produced with different standards quality list the possibilities for reuse in accordance with international Law. Was monitored from the wastewater treatment plant pilot consists of a UASB reactor followed by activated sludge whose effluents were used in this study not only physical-chemical and microbiological analyzes, but also for subsequent physical-chemical treatment in the laboratory with equipment jartest using two coagulants ferric chloride and aluminum sulfate. After the treatments combined six different samples were analyzed: UASB effluent, activated sludge effluent, treatments UASB-\'AL IND.2\'(\'SO IND.4\')IND.3\', UASB-\'FE\'CL IND.3\', activated sludge-activated sludge and activated sludge-\'FE\'CL IND.3\'. The tests with ferric chloride were better promoted removal of the microbiological indicators and (oo)cysts, COD and TSS. However, even after physical-chemical treatment will not be possible wastewater reuse in agriculture, urban and/or industrial, according international law and the WHO guidelines, since the concentration of indicator microorganisms is still very high. The average values of E. coli and total coliform and Giardia spp., even after the treatment which promoted better microbiological removal, were 4,31 x \'10 POT.2\', 7,68 x \'10 POT.3\' e 2,17 x \'10 POT.2\', respectively.

Page generated in 0.068 seconds