Spelling suggestions: "subject:"microscopia eletrônico dde varredura"" "subject:"microscopia eletrônico dee varredura""
81 |
Aplicações da técnica de corrente induzida por feixe de elétrons (EBIC) / Applications of the electron beam-induced current technique - EBICLima, Camila Faccini de January 2015 (has links)
A Medida de Corrente Induzida por Feixe de Elétrons (EBIC - do inglês Electron Beam-induced Current ) é uma técnica focada nas propriedades de transporte dos portadores de carga minoritários em materiais semicondutores, permitindo a medição direta de propriedades elétricas tais como comprimento de difusão e vida média dos portadores, localização de defeitos e caracterização de zonas de depleção em junções p-n. O contraste EBIC depende da eficiência da coleção de corrente na amostra, permitindo assim a direta visualização de características eletricamente ativas. A avaliação da metodologia de medida EBIC foi realizada através da caracterização de amostras de silício tipo-p e tipo-n, e comparação dos resultados com dados da literatura. Uma vez que a profundidade de penetração do feixe de elétrons do MEV na amostra depende da tensão de aceleração utilizada, foram realizadas medidas EBIC com diferentes tensões de aceleração para avaliar a resolução em profundidade da posição de uma junção p-n formada em uma amostra de silício tipo n implantada com íons de Ga com energia de 5 keV.A medida EBIC na seção transversal de células solares é promissora para a caracterização destes dispositivos, considerando a habilidade da técnica de resolver espacialmente regiões menores do que o tamanho de grão típicos (em torno de 1 m), fornecendo informações que seriam inacessíveis através das técnicas usualmente empregadas, como luminescência e curvas I-V, cujos resultados constituem valores médios representativos de escalas maiores do que a da camada ativa das células. Embora imagens EBIC sejam comumente utilizadas para a análise de defeitos em células solares, poucos trabalhos aplicam a técnica para a caracterização de seções transversais de células solares, especialmente células de terceira geração sensibilizadas por corante (DSSC) do tipo estado sólido. A estabilidade dos dispositivos durante as medições foi verificada, apoiando a aplicação da técnica EBIC na caracterização desse tipo de DSSC. Foram analisadas células com diferentes estruturas e espessuras da camada ativa, e caracterizações complementares com as técnicas EDS e GID foram feitas. Observou-se também a possibilidade de utilização da técnica no controle de qualidade e avaliação dos métodos de produção das células. Diferentes métodos de deposição da camada intermediária na estrutura das DSSCs foram testados, de forma a melhorar a adesão insatisfatória desta camada. A técnica EBIC mostrou-se adequada para a distinção entre células com boa adesão desta camada e células com defeitos de construção, permitindo a introdução de melhorias significativas na fabricação destes dispositivos. / Electron Beam-induced Current (EBIC) measurement is a technique focused on minority carrier transport properties in semiconductor materials, allowing direct measurements of several electrical properties, such as diffusion lengths and lifetime of the carriers, location of defects and depletion zone characterization in p-n junctions. EBIC contrast depends on the current collection efficiency in the sample, thus permitting a direct visualization of electronically active features. The evaluation of the EBIC measuring methodology was performed by the characterization of p- and n-type silicon and the comparison with results from the literature. Since the penetration depth of the electron beam in a sample depends on its acceleration voltage, the EBIC signal was acquired for variable voltage in order to evaluate the depth-resolved location of the p-n junction formed in the n-type silicon implanted with gallium at 5 keV. Direct measurement of EBIC profiles in cross-sections of solar cells is a promising method for device characterization, considering its spatial resolution is smaller than the typical grain sizes (about 1 m), providing informations otherwise inaccessible by the usually employed techniques, such as luminescence and V-I curves, that yield results that represent mean values of scales larger than that of the cell’s active layer. Although the EBIC imaging method is commonly used for defect analysis of solar cells, very few works have applied the thechnique to 3rd. generation solid state dye sensitized solar cell (DSSC) cross-sections. The stability of the devices during the measurement was verified in this work, supporting the application of the EBIC technique for the characterization of this type of DSSCs. DSSCs with different structures and active layer thickness were analyzed, and complementary characterizations with EDS and GID techniques were performed. The applicability of the EBIC thecnique in device quality control, as well as production methods evaluation was observed. Different deposition methods of the intermediate layer of the DSSC structure were tested, in orde to improve the unsatisfactory adhesion of this layer. EBIC showed to be the adequate thechnique to differentiate between well adhered and poorly constructed DSSCs, allowing to introdenuce significant improvements in the device fabrication.
|
82 |
Análise da interação do MTA e DO ácido clorídrico com a dentinaFelippe, Gabriela Santos January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:43:26Z (GMT). No. of bitstreams: 1
340687.pdf: 1172274 bytes, checksum: 8271b88f3351900159a6642802607a42 (MD5)
Previous issue date: 2016 / O objetivo deste trabalho foi avaliar, de forma subjetiva, o aspecto estrutural da dentina após desmineralização com ácido clorídrico (HCl) 6M e 12M, com ou sem interação prévia com MTA/PBS, e identificar, quando necessário, os elementos constituintes da estrutura remanescente. A partir de 6 dentes bovinos, foram obtidos 24 discos de dentina com aproximadamente 2 mm de espessura, os quais foram distribuídos, aleatoriamente em 3 grupos experimentais (n = 8). Nos discos do Grupo 1, o espaço referente ao canal radicular foi preenchido com MTA e os discos permaneceram em contato com tampão fosfato-salino (PBS) por 30 dias. Em seguida, foi realizada a fixação dos discos, o embutimento em resina, o polimento e a desmineralização com HCl 6M por 30 seg, para posterior análise em microscopia eletrônica de varredura (MEV). Nos discos dos grupos 2 e 3, o espaço do canal permaneceu vazio. Após o embutimento em resina e polimento, foi feita a fixação e posterior desmineralização, por 30 seg, com HCl na concentração de 6M e 12M respectivamente. Todos os discos foram, então, preparados para avaliação em MEV e energia dispersiva de Rx (EDX) para verificar as alterações estruturais ocorridas na dentina, bem como a composição química de algumas das estruturas visualizadas. O HCl promoveu perda de grande parte da dentina intertubular e, em menor grau, da dentina peritubular. As maiores alterações foram evidenciadas nas amostras do Grupo 3. Foi possível concluir que: o aspecto estrutural da dentina após a desmineralização com HCl 6M e 12M mostrou-se similar, independentemente da interação prévia com MTA/PBS; as alterações estruturais foram mais evidentes nas amostras tratadas com HCl 12M, e a análise em MEV-EDX revelou que a composição das estruturas remanescentes era compatível com a da dentina.<br> / Abstract : The aim of this study was to analyze the morphological appearance of the dentin surface after demineralization with 6M e 12M chloride acid (HCl), with or without previous interaction with MTA/PBS, and to identify the remnants composition. Methods: Twenty-four 2 mm dentin discs were obtained from 6 bovine teeth, and randomly divided into 3 experimental groups (n = 8). In discs of group 1, the cavities were filled with MTA and the discs were imersed in PBS. After 30 days, they were fixed, embedded in epoxy resin, polished and demineralized with 6M HCl for 30 sec, for further scanning electron microscopy (SEM) analysis. In discs of groups 2 and 3, the cavities remained empty. After embedment and polishment, they were fixed and demineralized, for 30 sec, with 6M e 12M HCl, respectively. All discs were then prepared for SEM and SEM-EDX analysis to verify morphological modifications on dentin surface and the elemental composition of some structures. Results: The HCl lead to a great loss of intertubular dentin and part of the peritubular one. The greater modifications were observed in group 3. Conclusions: The morphological appearance of dentin after demineralization with 6M e 12M HCl was similar, despite the previous interaction with MTA/PBS; the structural modifications were more significant in the samples treated with 12M HCl; and SEM-EDX analysis showed the composition of the remnants structures was similar to dentin.
|
83 |
Avaliação radiográfica e microscópica (MEV-Microscopia eletrônica de varredura), do preparo apical promovido por três diferentes técnicas para preparo biomecânico dos canais radiculares, empregando sistemas rotatóriosSilva, Ronaldo Souza Ferreira da [UNESP] 09 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-11-09Bitstream added on 2014-06-13T19:20:37Z : No. of bitstreams: 1
silva_rsf_dr_arafo.pdf: 1974309 bytes, checksum: 1bf1e5c7818e9a913ac6eea6b869c038 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Para este estudo, foram utilizadas quarenta raízes mesiais de molares inferiores humanos (recém extraídos), com curvatura e conformação semelhantes, divididas, aleatoriamente, em quatro grupos experimentais. Desta forma, somente os canais mésio-vestibulares foram instrumentados por meio da técnica “crown-down”, utilizando-se os seguintes instrumentos rotatórios: Hero Apical (Clássico), Light Speed LSX, S-Apex; além das Limas manuais tipo KFlexofile. Avaliou-se então, radiográfica e microscopicamente (MEV - Microscopia Eletrônica de Varredura), o preparo apical promovido por estes diferentes instrumentos. Radiograficamente, as imagens das raízes estudadas foram analisadas e comparadas antes e após o preparo biomecânico (em cada grupo experimental), procurando-se observar, e até mesmo mensurar, possíveis modificações. Concluiu-se que, independentemente do tamanho dos desvios cervicais ocorridos (em ângulos/graus), após o preparo biomecânico, não houve diferença estatística significante com relação aos desvios resultantes nos terços apicais nos diferentes grupos (P=0,9064). De acordo com a análise microscópica da região apical, houve uma relação de continuidade entre o canal radicular instrumentado e o milímetro final (não instrumentado), dentre todos os grupos. / A Radiographic and SEM (scanning electronic microscope) evaluation in apical transportation was studied. Four similar groups (n=10) of mandibular first molar with curved canals were selected on the basis of their morphology and randomly divided. Only mesiobuccal canals were prepared by the crown-down technique, using rotary instrumentation with Hero Apical-Classic model (Group I), Light Speed LSX (Group II), S-Apex (Group III) and manual instrumentation with K-Flexofile (Group IV). The root images studied were analyzed and compared before and after the instrumentation into each group. The radiographic findings didn’t show a statistically significant difference between groups in the apical third (p=0.9064). SEM evaluation showed a continuous relationship between the root canal instrumentation and the ultimate millimeter (that was not prepared) in all studied groups.
|
84 |
Resistência de união ao microcisalhamento de sistemas adesivos distintos em substrato dentinário normal e hipermineralizado artificialmente /Kubo, Cinthia Sawamura. January 2013 (has links)
Orientador: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Banca: Cristina Magnani Felício / Resumo: O objetivo deste trabalho foi avaliar a resistência de união ao microcisalhamento de diferentes sistemas adesivos autocondicionantes de dois passos e passo único, com graus de acidez distintos, em substrato dentinário normal e hipermineralizado artificialmente. Sessenta e cinco (n = 65) incisivos bovinos hígidos foram selecionados, sendo cinqüenta e sete (n = 57) para o teste de resistência de união ao microcisalhamento e oito (n = 8) para a observação da interface adesiva em microscopia eletrônica de varredura (MEV). Os dentes tiveram suas raízes removidas com o auxílio de um motor elétrico e disco diamantado. As coroas tiveram sua superfície vestibular desgastada com o objetivo de expor a superfície dentinária plana, sendo os dentes divididos aleatoriamente em dois diferentes grupos, de acordo com o tipo de dentina: normal (N/ n = 28) e hipermineralizada artificialmente (H/ n = 29). O conjunto H recebeu tratamento para hipermineralização e um espécime foi selecionado aleatoriamente para observação em MEV para a confirmação do procedimento de hipermineralização. Cada coroa foi incluída em um cilindro de PVC com o auxílio de resina acrílica autopolimerizável. Cada grupo foi dividido em 4 subgrupos de acordo com o sistema adesivo autocondicionante empregado: Clearfil SE Bond (n=7) - suave de dois passos, Adhese (n = 7) - moderado de dois passos, Adper Easy One (n = 7) - suave de passo único, Optibond All in One (n = 7) - moderado de passo único. Sobre essa superfície foram inseridos e fotopolimerizados cilindros de resina composta (FiltekTM Z350 XT - 3M ESPE). Após período de armazenagem de 24 horas em ambiente úmido a 37°C (± 1°C), foram realizados os testes de microcisalhamento em máquina de ensaios mecânicos com velocidade de 0,5 mm/min até à fratura dos espécimes. A fim de verificar a presença de interface e/ou a aparência de tags de resina, um... / Abstract: The aim of this study was to evaluate the microshear bond strength of different self-etching two-step and all-in-one adhesive systems, with different acid concentrations to sound and artificially hypermineralized dentin. Sixty-five (n = 65) healthy bovine incisors were selected, fifty-seven (n = 57) to test the microshear bond strength and eight (n = 8) to observe the presence of adhesive interface with scanning electron microscopy (SEM). Teeth have roots removed using an electric motor and diamond disc. Vestibular surface were ground flat to expose a flat dentin surface, the teeth were divided randomly into two different groups according the type of dentin: sound (N / n = 28) or artificially hypermineralized (H / n = 29). The set H received hypermineralizing treatment and a specimen was selected randomly to observe the procedure with SEM. Each crown was included in a PVC cylinder using acrylic resin. Each group was divided into 4 subgroups according to dentin adhesive systems: Clearfil SE Bond (n = 7) - mild two steps, AdheSE (n = 7) - moderate two steps, Adper Easy One (n = 7) - mild all-in-one, Optibond All in One (n = 7) - moderate all-in-one. Then were inserted and cured resin cylinders (Filtek Z350 XT - 3M ESPE) at the surface. After 24 hours storage at 37 ° C (± 1°C), for humid environment, microshear was taked using mechanical testing machine with 0.5 mm/min speed until fracture of the specimens. For analysis the presence of an interface and/or appearance of resin tags, a specimen of each group was prepare for evaluating the adhesive interface with SEM. Bond strengths data were subjected to ANOVA and Bonferroni (p<0.05) test. The bond strength values were Clearfil = 15.65 ± 6.18, AdheSE = 14.71 ± 10.36, Easy One = 21.92 ± 6.40, OptiBond = 28.43 ± 6.55 to sound dentin and Clearfil = 20.96 ± 8.06, AdheSE = 17.23 ± 5.16, Easy One = 31.79 ± 8.31, OptiBond = 23.29 ± 3.66 to... / Mestre
|
85 |
Avaliação da alteração de cor, difusão de peróxido de hidrogênio e citotoxicidade trans-amelodentinária causadas por diferentes técnicas de clareamento dental /Almeida, Letícia Cunha Amaral Gonzaga de. January 2013 (has links)
Orientador: André Luiz Fraga Briso / Banca: João Eduardo Gomes Filho / Banca: Carlos Alberto de Souza Costa / Banca: Renato Herman Sundfeld / Banca: Marcelo Giannini / Resumo: Tem sido demonstrado que o tempo que o clareador permanece sobre o esmalte, a concentração do produto, a espessura do esmalte e da dentina presente em cada grupo de dentes, podem influenciar na penetração do peróxido na câmara pulpar e que esta ocorrência pode estar relacionada à inflamação da polpa e que nem sempre esses fatores estão associados à maior efetividade da técnica. Sendo assim, o objetivo deste estudo foi avaliar a alteração de cor, a citotoxicidade e a difusão do H2O2 causados por diferentes protocolos de clareamento dental. O presente estudo foi dividido em dois capitulos, no capitulo 1 foram estudados protocolos de clareamento de consultório: peróxido de hidrogênio a 35% (PH35%), três aplicaçoes de 15 minutos ou uma aplicação de 45 minutos; e peróxido de hidrogênio a 20% (PH20%) uma aplicação de 45 minutos. No capitulo 2 foram estudados protocolos caseiros: peróxido de carbamida 10% (PC10%), por 3 horas ou 1,5 horas e peróxido de hidrogênio 6% (PH6%), por 1,5 horas ou 45min. Para tanto, discos de esmalte/dentina foram clareados por 7, 14 e 21 dias pela técnica caseira ou receberam 3 sessões de clareamento de consultório, uma por semana. A alteração de cor dos espécimes (E) foi analisada por espectrofotometria de reflexão UV. Discos adaptados a câmaras pulpares artificiais foram posicionados em compartimentos contendo 1 ml de tampão acetato ou meio de cultura, de forma que a superfície dentinária permaneceu em contato direto com estas soluções. Imediatamente após o clareamento, o total de PH foi quantificado no tampão acetato e o meio de cultura foi aplicado por 1h em células MDPC-23, previamente semeadas em placas de acrílico. O metabolismo celular foi avaliado pelos teste MTT e a morfologia celular foi avaliada através de microscopia eletrônica de varredura. No capitulo 1 os resultados mostraram que ao final do tratamento a alteração ... / Abstract: It has been shown that the time that the bleach gel keeps on the enamel, the product concentration, the thickness of enamel and dentin in each group of teeth, among other factors, can influence the penetration of peroxide in the pulp chamber and that this occurrence may be associated with pulp inflammation and tooth sensitivity, and these factors are not associated with higher effectiveness of the technique. Thus, the aim of this study was to evaluate the color change, the cytotoxicity and the diffusion of H2O2 caused by different bleaching protocols. This study was divided into two chapters , in chapter 1 in-office bleaching protocols were studied: 35 % hydrogen peroxide ( 35% HP), three aplications of 15 minutes or an application of 45 minutes; and 20% hydrogen peroxide (20%HP) an application of 45 minutes. At-home protocols were studied in chapter 2: 10% carbamide peroxide (10 % CP ) for 3 hours or 1.5 hours; and 6% hydrogen peroxide (6% HP) for 1.5 hours or 45 min . Therefore, disks of enamel / dentin were bleached for 7, 14 and 21 days by the at-home technique or received 3 in office bleaching sessions, one per week. The color alteration of the specimens (E) was analyzed by spectrophotometry UV reflection. Discs adapted to artificial pulp chambers were placed in wells containing 1 ml of acetate buffer or culture medium, so that the dentine surface remained in contact with these solutions. Immediately after the bleaching, the total of HP was measured in acetate buffer and culture medium was applied for 1h at MDPC -23 cells previously seeded in acrylic plates. Cell metabolism was assessed by MTT assay and cell morphology was evaluated by scanning electron microscopy. In chapter 1 the results showed that at the end of the treatment the color change was similar in all bleaching protocols, noting that although there was less intense penetration of hydrogen peroxide in the group treated with lower concentrations ... / Doutor
|
86 |
Morfologia da testa e potencial fisiológico de sementes de soja /Silva, Monalisa Alves Diniz da. January 2003 (has links)
Orientador: Roberval Daiton Vieira / Banca: Nelson Moreira de Carvalho / Banca: Rinaldo Cesar de Paula / Banca: Francisco Humberto Dubbern de Souza / Banca: Ana Dionisia da Luz Coelho Novembre / Resumo: Durante o envelhecimento das sementes, a redução do potencial fisiológico é conseqüência do processo de deterioração que pode levar a alterações na anatomia da testa, as quais tendem a interferir no processo de embebição, e conseqüentemente, no potencial fisiológico. O presente trabalho teve como objetivo avaliar anatomicamente a testa de sementes de dois cultivares de soja, por intermédio do uso da microscopia eletrônica de varredura, após o envelhecimento acelerado e o armazenamento, assim como o seu potencial fisiológico. Foram conduzidos dois experimentos, no primeiro os tratamentos consistiram de cinco períodos de envelhecimento acelerado (0, 24, 48, 72 e 96 horas) a 42°C e, aproximadamente, 100% de umidade relativa do ar. Findo os períodos de envelhecimento foram avaliados o teor de água das sementes e a germinação; e, posteriormente, após secagem em estufa com circulação de ar, seções transversais da testa de 10 sementes de cada tratamento foram eletromicrografadas. No segundo experimento, os tratamentos constaram do armazenamento das sementes, em câmara fria e ambiente de laboratório, e três períodos de avaliação, zero, três e seis meses, com avaliações do teor de água, da germinação, do vigor (comprimento de plântula, matéria seca, envelhecimento acelerado, frio, condutividade elétrica e emergência de plântula), da anatomia da testa, com o uso da microscopia eletrônica de varredura. Houve a redução do potencial germinativo e o aumento do colapso das células da camada hipodérmica da testa, de ambas as cultivares, à medida que o período de envelhecimento acelerado aumentou. O teste de condutividade elétrica detectou diferenças significativas entre os períodos de armazenamento para as sementes armazenadas em laboratório, para as duas cultivares... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: During the aging of the seeds, the reduction of the physiologic potential is consequence of the deterioration process that can lead to alterations in the anatomy of the coat, which tend to interfere in the process of imbibition, and consequently, in the physiologic potential of the seed. The present work had as objective to evaluate anatomically the coat of seeds of two soybean cultivars, through the use of the scanning electron microscopy, after the accelerated aging and the storage, as well as the physiologic potential. Two experiments were conducted, in the first, treatments consisted of five periods of accelerated aging (0, 24, 48, 72 and 96 hours) at 42oC and approximately 100% of relative humidity of the air. At the end of the aging periods, the water content of the seeds and the germination percentage were appraised; later, after drying process in oven with air circulation, traverse sections of 10 seedcoat of each treatment were eletromicrographed. In the experiment two, the treatments consisted of the storage of the seeds in two different conditions: cold ambient and laboratory conditions, and three evaluation instances zero, three and six months, respectively, after, of storage. At these occasions, the following determinations were made: water content, seed germination, and vigor evaluated by the tests: seedlings length, dry matter, accelerated aging, cold, electric conductivity and seedlings field emergence. The evaluation of the anatomy of the coat with the use of the scanning electron microscopy followed the same procedure of the experiment 1. There were reduction of the germination potential and increase of the colapse of the hypodermic layer of the coat, of both cultivars, as the period of accelerated aging increased. The storage of the seeds for six months, under cold ambient and under laboratory, conditions can influence a larger collapse of the hypodermic layer of the coat... (Complete abstract, click electronic access below) / Doutor
|
87 |
Efeito da agitação mecânica do hipoclorito de sódio sobre a interface de adesão do cimento endodôntico na dentina radicular /Galvani, Lucas David January 2018 (has links)
Orientador: Milton Carlos Kuga / Resumo: O objetivo do presente estudo foi avaliar a incidência de resíduos nas paredes dentinárias dos canais radiculares após a energização da solução de hipoclorito de sódio a 2,5% (NaOCl a 2,5%), por meio de ativação ultrassônica passiva (PUI) ou sônica (XP Endo Finisher, XP Clean ou Easy Clean). Quarenta caninos humanos extraídos, obtidos do Banco de dentes da Faculdade de Odontologia de Araraquara (FOAr/UNESP), foram previamente radiografados e selecionados com anatomia radicular semelhantes. Na sequência, as raízes foram padronizadas, a partir do ápice radicular, com a extensão de 17 mm e realizado o preparo químico e mecânico do canal radicular até o instrumento F5 (ProTaper; Dentsply, Petrópolis, RJ, BR), conforme a técnica recomendada pelo fabricante. Entre cada troca de calibre de instrumento, foi realizada a irrigação com 5 mL de NaOCl a 2,5%. Concluído esta fase, as raízes foram incluídas em silicone de alta densidade, previamente adaptadas em frascos de Eppendorf de 2,0 mL. Posteriormente, estas mesmas raízes foram removidas do silicone e seccionadas longitudinalmente no sentido mésio-distal. O segmento do canal radicular da face palatina será demarcado em 3 pontos distintos, correspondentes aos terços cervical, médio e apical. Após, as raízes foram remontadas no padrão de silicone e os canais radiculares submetidos a irrigação final com o NaOCl a 2,5% e energizados com um dos seguintes métodos: G1- Xp Endo Finisher; G2- XP Clean, G3- Easy Clean ou G4- PUI (Ativação Ultr... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the study was to evaluete the occurrance of dentin walls residue of after energyzing a solution of sodium hypochloritorite in 2,5%(NaOCL a 2,5%), by Passive Ultrassonic Irrigation (PUI) or sonic (XP Endo Finisher, XP Clean ou Easy Clean). Forty extracted human canines, obtained from a tooth bank at the Dentristy School in Araraquara (FOAr/UNESP) were previously radiographed and selected with similar root anatomy. After that, the roots will be standardized from the root apex, with 17mm extension and chemical and mechanical preparation will be carried out until the F5 instrument, according to the technique recommended by the manufacture. Among each instrument caliber shift, irrigation was carried out with 5 ml of NaOCl at 2,5%. When this step was over, the roots were included in high density silicone, previously adapted in 2.0 ml eppendorf. After wards these were removed from the silicone and split lengthwise, mesiobuccal from. The palatine face root canal segment will be demarcarted in 3 distinc points, correspondent to the cervical, medium an apical thirds. After that, the roots were reassembled under the silicone pattern and the root canals were submitted to a final irrigation with NaOCl at 2,5% energized with one of the following methods: G1 XP Endo Finisher, G2: XP Clean, G3: Easy Clean and G4: PUI (Passive Ultrasonic Irrigation). Next, to roots were analyzed through scanning electron microscopy, assessing cervical, medium and apical thirds in arder to evaluate ... (Complete abstract click electronic access below) / Mestre
|
88 |
Métodos para caracterização de meios filtrantes contendo nanofibrasSalussoglia, Ana Isabela Pianowski 02 May 2016 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-10-25T17:46:20Z
No. of bitstreams: 1
DissAIPS.pdf: 2934102 bytes, checksum: 51f85d77e523c0342ac85dd9bf0aa211 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-11-08T19:14:48Z (GMT) No. of bitstreams: 1
DissAIPS.pdf: 2934102 bytes, checksum: 51f85d77e523c0342ac85dd9bf0aa211 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-11-08T19:14:53Z (GMT) No. of bitstreams: 1
DissAIPS.pdf: 2934102 bytes, checksum: 51f85d77e523c0342ac85dd9bf0aa211 (MD5) / Made available in DSpace on 2016-11-08T19:14:59Z (GMT). No. of bitstreams: 1
DissAIPS.pdf: 2934102 bytes, checksum: 51f85d77e523c0342ac85dd9bf0aa211 (MD5)
Previous issue date: 2016-05-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / It is necessary knowing the characteristics of the filter media and how they influence the
filtration process to improve the filter media. With this, the aim of this study was to
characterize the filter media containing nanofibers. The characterization of the filter was
made by testing in experimental unit and through images generated by scanning
electron microscopy analysis (SEM), which were treated with the softwares Gimp 2 and
Image-Pro Plus 7.0 and electronic spreadsheet. In the experimental unit were conducted
efficiency and permeability tests of the filter media with filtration area of 5.3 cm2. The
efficiency was determined by the Particle Analyzer for Electric Mobility with face
velocity of 4.7 cm/s. The particles were generated from a NaCl solution of 5 g/l. It was
obtained the efficiency 74% considering the whole range of particle diameter. The
permeability was obtained by Darcy equation it was possible to find the permeability of
2.5 10-08 cm2. The quality factor was calculated with efficiency and pressure drop and
was 22.0 kPa-1. The SEM images were analyzed by two microscopes. The images
generated by SEM - Magellan were greater number of pixels than images generated by
SEM – FEG, because of this the images generated by SEM - Magellan were more
accurate. The diameter of the nanofibers was evaluated by two methods. The automated
method was more agile than the manual. Furthermore, it was made the evaluation of
distribution models for the histograms of fiber diameters in the lognormal model was
the best fit. / Conhecer as características do meio filtrante e entender como elas influenciam no
processo de filtração é essencial para aperfeiçoá-lo. Tendo isto em vista, o objetivo
deste trabalho foi caracterizar o meio filtrante contendo nanofibras. A caracterização do
filtro foi feita por meio de testes em unidade experimental e por meio de análises de
imagens geradas por microscopia eletrônica de varredura (MEV), que foram tratadas
com os softwares Gimp 2 e Image-Pro Plus 7.0 juntamente com software de planilhas
eletrônica. Na unidade experimental foram realizados testes de eficiência de coleta e
permeabilidade do meio filtrante, com área de filtração de 5,3 cm2. A eficiência de
coleta foi determinada pelo Analisador de Partículas por Mobilidade Elétrica com
velocidade de filtração foi mantida em 4,7 cm/s durante todo o experimento. As
partículas foram geradas a partir de solução de 5 g/l de NaCl. Foi obtida eficiência de
coleta de 74% considerando toda gama de diâmetro de partículas analisadas. A
permeabilidade foi obtida medindo a queda de pressão para oito valores préestabelecidos
de velocidade superficial do aerossol. A viscosidade do fluido foi
considerada 1,7 10-7 Pa s. E através da Equação de Darcy foi possível encontrar a
permeabilidade do meio filtrante de 2,5 10-08 cm2. Após a determinação da eficiência e
queda de pressão a 4,7 cm/s foi calculado o fator de qualidade que foi de 22,0 kPa-1.
Foram analisadas imagens geradas por dois microscópios de MEV. Foi possível
perceber que as imagens geradas pelo microscópio MEV- Magellan possuem maior
quantidade de pixels, logo os dados obtidos por estas imagens são mais precisos. O
diâmetro das nanofibras foi avaliado por dois métodos. O método automatizado
mostrou-se mais ágil que o manual. Além disso, foi feita a avaliação de modelos de
distribuição para os histogramas de diâmetros de fibras, em que o modelo LogNormal
foi o que melhor se ajustou.
|
89 |
Avaliação in vitro do comportamento de resinas compostas, quanto a microdureza , sorção e análise em mev, após desafio ácido e/ou aplicação de soluções fluoretadas /Firoozmand, Leily Macedo. January 2007 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Luzia da Glória Corrêa Coelho / Banca: Marcos Vinícios Queiroz de Paula / Banca: Clovis Pagani / Banca: César Rogério Pucci / Resumo: O objetivo desta pesquisa foi o de avaliar in vitro o comportamento de resinas compostas (RC) submetidas ao desafio ácido e/ou aplicação de soluções fluoretadas, através dos testes de microdureza, sorção e análise morfológica em microscopia eletrônica de varredura (MEV). Foram empregadas as RCs: microhíbridas - Z100 (3M), Estelite Σ (J Morita) e nanoparticulada - Filtek™ Supreme (3M), na cor A3, inseridas em matriz de aço-inoxidável com cavidades de 5mm de diâmetro e 2mm de profundidade, fotopolimerizadas por aparelho de luz halógena, XL 3000 (3M) por 40s. Formaram-se 3 grupos contendo 25 corpos-de-prova (cps) de cada RC, num total de 75 cps. Estes foram pesados após a sua confecção em Balança Digital inicialmente e após armazenamento em água destilada por 24h, para a verificação da sorção de água. O teste de microdureza foi realizado com o Microdurômetro Digital Vickers, utilizando 50g de carga por 15s de permanência para a mensuração inicial dos 75 cps. Destes 20 cps de cada RC foram submetidos ao desafio ácido em uma solução des-remineralizante por 10 dias, e 5 permaneceram como controle em água destilada. Os cps foram novamente pesados e submetidos a 2a leitura da microdureza. Em cada grupo de RC metade dos cps (n=10) foi submetida à aplicação tópica do flúor neutro e na outra metade ao FFA 1,23% por 48 min realizando-se posteriormente a 3a leitura da microdureza. Para a avaliação em MEV foram confeccionados outros 6 cps de cada tipo de RC e submetidos ao desafio ácido e soluções fluoretadas sendo que em cada fase, procedia-se a visualização morfológica da superfície. Para os dados de sorção de água foram utilizados os testes ANOVA e Tukey e para os dados de microdureza os testes ANOVA de medidas repetidas, ANOVA split plot e Tukey. / Abstract: The aim of this study was to assess through hardness test, sorption test and morphological analyses in scanning electronic microscopy (SEM) the composite resin (CR) behavior submitted to the influence of acid challenge (de-remineralization process) and/or topic application of fluoride solutions. The CR: microhybrids - Z100 (3M), Estelite Σ (J Morita) and nanoparticulated - Filtek™ Supreme (3M), with A3 shade were inserted in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a XL 3000 halogen light curing unit, (3M) for 40s. Three groups were formed with 25 samples of each CR, making a total of 75 samples. They were initially weighed in Digital Scale after they were made and after they were stored for 24h in distilled water to verify the water sorption. For the microhardness test a Vickers Digital Microhardmeter, using 50g load and 30s time was used to measure the initial values of the 75 samples. From this 20 samples of each material were submitted to the acid challenge in a de-remineralized solution for 10 days, and 5 samples were stored in distilled water as a control group. The samples were again weighted and submitted to a second microhardness measure. In each group of the CR half of samples (n=10) were submitted to the topic application of neutral fluoride and the other half to the 1.23% acidulated phosphate fluoride (APF) for 48 min, making subsequently the third microhardness measure. For the SEM evaluation, 6 others samples were made for each CR and submitted to acid challenge and fluoride solutions considering that in each phase, the surface morphologic visualization was made. The ANOVA and Tukey statistical tests were used for the sorption data, and the ANOVA two way, ANOVA split plot and Tukey tests were used for hardness values. / Doutor
|
90 |
Influência da fixação e de métodos de secagem na detecção de alterações proliferativas ultraestruturais induzidas pelo Diuron no urotélio vesical de ratos wistar /Fava, Rafaela Marono. January 2014 (has links)
Orientador: Maria Luiza Cotrim Sartor de Oliveira / Coorientador: Mirielen Garcia Nascimento e Pontes / Banca: Maria Lucia Zaidan Dagli / Banca: Daniela Carvalho dos Santos / Resumo: Não disponivel / Abstract: Diuron is a substituted urea herbicide, carcinogenic to the rat urinary bladder at high dietary levels (2500 ppm). Different scanning electron microscopy (SEM) processing methods resulted in differing observations of early urothelial changes induced by exposure to this herbicide. This study evaluated the influence of SEM processing methods on the detection of urothelial alterations induced by diuron. Male Wistar rats were divided into 3 groups: control (basal diet), 7.1% Sodium Saccharin (NaS) (positive control) and 2500 ppm diuron, and fed for 7 days or 15 weeks. Urinary bladders were fixed with Bouin's or glutaraldehyde fixative and processed by critical point drying (CPD) or by hexamethyldisilazane (HMDS) for comparison of the cytotoxic and proliferative changes induced by diuron in the urothelium. Histological and cell proliferation evaluations were also performed. After seven days, no differences in the incidence of histological urothelial lesions or labeling indices were detected among the groups; however, the incidence of urothelial lesions after 15 weeks was significantly increased in the animals fed diuron or NaS. After seven days or 15 weeks, the severity of urothelial alterations was significantly higher in animals fed with diuron. Both fixative and drying methods allowed for the identification of prenecrotic swollen superficial cells in the urothelium after seven days exposure to 2500 ppm diuron. Our results confirmed that the presence of prenecrotic swollen cells in the urothelium is an early key event due to diuron cytotoxicity and is not an artifact related to the processing methods used / Mestre
|
Page generated in 0.1388 seconds