• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 48
  • 1
  • 1
  • Tagged with
  • 132
  • 28
  • 28
  • 27
  • 27
  • 26
  • 22
  • 20
  • 20
  • 20
  • 20
  • 19
  • 18
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

AVALIAÇÃO DO ESPAÇO DISPONÍVEL PARA ERUPÇÃO DOS SEGUNDOS E TERCEIROS MOLARES SUPERIORES PERMANENTES APÓS A DISTALIZAÇÃO DOS PRIMEIROS MOLARES SUPERIORES PERMANENTES / EVALUATION OF THE SPACE AVAILABLE FOR ERUPTION OF PERMANENT MAXILLARY SECOND AND THIRD MOLARS, AFTER DISTALIZATION OF PERMANENT MAXILLARY FIRST MOLARS

Silva, Francisco Alexandre Baptista da 18 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:11Z (GMT). No. of bitstreams: 1 Francisco Alexandre Baptista da Silva.pdf: 816513 bytes, checksum: 920442db69c519bfaf2584c0fc9bfe43 (MD5) Previous issue date: 2008-02-18 / This study aimed to cephalometrically evaluate the space and positioning of crowns of unerupted permanent maxillary second and third molars at the region of the maxil-lary tuberosity during distalization of maxillary first molars, as well as to verify the cor-relation between these two variables. The sample was composed of 38 right lateral cephalograms, obtained of 19 young Brazilian patients, both Caucasoid and of Afri-can descent, being 6 males and 13 females, with mean age 9 years 5 months 13 days. The methodology initially comprised division of periods, namely initial (T1) and after distalization of the permanent maxillary first molar (T2) in a mean period of 10 months and 23 days. The space and angulation of existing crowns was analyzed with the aid of an intracranial reference line (line M), which was delineated from two points, the point SE located on the sphenoethmoidal suture, and the point Pt located at the anterior region of the pterygopalatine suture. This reference line was trans-ferred to the point F (line M ), located at the most posterior and inferior region of the maxillary tuberosity. The evaluated space was located from the line M to the distal aspect of the permanent maxillary first molar. Statistical analysis was performed by the Student s t test; correlation between the space and angulation was calculated by the Pearson correlation coefficient. It was concluded that the corresponding space between the distal aspect of permanent maxillary first molars and the end of the max-illary tuberosity, at the initial stage and after distalization, is not enough for the erup-tion of permanent maxillary second and third molars. The angulation of crowns in the initial period and after distalization revealed distal angulation of the crowns. With re-gard to the correlation of angulations of crowns of the permanent maxillary second and third molars and the space for eruption, it was observed that the greater the dis-tal angulation of crowns, the smaller will be the space available for eruption.(AU) / A presente pesquisa tem como objetivo avaliar cefalometricamente, o espaço e po-sicionamento das coroas dos segundos e terceiros molares superiores permanentes não erupcionados na região da tuberosidade maxilar durante a distalização dos pri-meiros molares superiores, além de verificar a correlação entre estas duas variáveis. A amostra foi constituída de 38 telerradiografias em norma lateral direita, obtidas de 19 pacientes, jovens brasileiros, leucodermas e melanodermas, sendo 6 do sexo masculino e 13 do sexo feminino, com idade média de 9 anos 5 meses 13 dias. A metodologia constou inicialmente da divisão dos tempos (T1) inicial, e após a distali-zação do primeiro molar superior permanente em (T2) por um período médio de 10 meses e 23 dias. Para avaliação do espaço e angulação das coroas existente utili-zou-se uma Linha referencial intracraniana (Linha M) sendo esta demarcada, a partir de dois pontos, o ponto SE localizado na sutura esfenoetmoidal, e o ponto Pt locali-zado na parte anterior da fossa pterigopalatina. Esta linha referencial foi transferida até o ponto F, (Linha M ) ponto este localizado na região mais posterio-inferior da tuberosidade maxilar. O espaço avaliado compreendeu entre a Linha M , até a face distal do primeiro molar superior permanente. Na análise estatística usou-se o teste t (Teste t Student) , e na correlação entre espaço e angulação foi utilizado o coefi-ciente de correlação de Pearson. Concluímos que o espaço correspondente entre a distal dos primeiros molares superiores permanentes e extremidade da tuberosidade maxilar, na fase inicial e após a movimentação distal, não é suficiente para a erup-ção dos segundos e terceiros molares superiores permanentes. A angulação das coroas na fase inicial e após a movimentação distal posicionam-se com angulações mais para distal. Quanto à correlação das angulações das coroas dos segundos e terceiros molares superiores permanentes e o espaço para erupção verificamos que quanto maior a angulação das coroas para distal, menor os espaços oferecidos para a erupção.(AU)
132

Efeito do número de pinos de fibra de vidro na resistência à fratura, deformação estrutural e distribuição de tensão em molares tratados endodonticamente

Barcelos, Luciana Mendes 12 February 2016 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The aim of this study was to evaluate the biomechanical effect of the presence and number of fibreglass post in endodontically treated molars restored with composite resin. 45 human molars were selected, included in polystyrene resin cylinders with simulation of the periodontal ligament and endodontically treated. These teeth were randomized into three groups (n = 15): Wfgp, without fibreglass post and restored with Filtek Z350 XT; 1fgp, 1 fiberglass post Exact #2 cemented in the distal root with RelyX U200 and restored with Z350XT; and 2fgp, 2 fiberglass posts cemented with RelyX U200, one in the distal root and the other in the mesiobuccal root, restored with Z350XT. The specimens were submitted to mechanical fatigue with axial load of 50N. The tooth remaining deformation was measured using extensometers (n = 10) during occlusal loading of 100N and then until fracture. The other teeth (n = 5) were used to calculate the modulus of elasticity (GPa) and Vickers hardness (VH, N/mm2) of the enamel, dentin composite resin and fiberglass post in two positions: parallelly and transversally to the long axis of the post. The stress distribution was analyzed using three dimensional finite elements model, generated from micro-CT image of an intact tooth with its geometry similar of those used in the in vitro study. The calculated mechanical properties were used to characterize models of finite element analysis. The data of deformation and fracture resistance were tested for normality (Shapiro-Wilk) and equivalence of variances (test Levene), followed by parametric statistical tests appropriated for each test. One way Anova was performed for the axial compressive strength values, tooth remaining deformation and fracture resistance. Multiple comparisons were performed using Tukey test. The mean fracture data were submitted to the Chi-square test. Factorial analysis of variance on two factors was carried out considering as factors in study: the tooth surface deformation (B and L) and rehabilitation technique. All tests done had significance level α = 0.05 and all analyses were performed with the statistical program Sigma Plot version 13.1 (Systat Software, San Jose, CA, USA). The use of two fiber glass posts resulted in lower fracture resistance than the groups without fiber glass - 22 - post and with one fiber glass post. During occlusal loading of 100N lingual surface of the remaining tooth showed higher deformation for all groups. The absence of fiber glass post resulted in significantly higher values of stress in the root and more irreparable fracture modes than the other groups. The use of a fiber glass post resulted in better ratio deformation/fracture resistance. The concentration of stress in the furcation area was slightly reduced with use of fiber glass post. It is concluded that the use of one fiber glass post to rehabilitated molars with direct composite resin showed higher resistance to fracture than the use of two fiberglass posts, lower tooth remaining deformation, better stress distribution and failure pat more repairable when compared to molars restored without use of fiber-glass post / O objetivo deste trabalho foi avaliar o efeito biomecânico da presença e do número de pinos de fibra de vidro em molares tratados endodonticamente e restaurados de forma direta com resina composta. Quarenta e cinco molares humanos foram selecionados, incluídos em cilindros de resina de poliestireno com simulação do ligamento periodontal e tratados endodonticamente. Estes dentes foram randomizados em três grupos (n=15): Spfv, sem pino de fibra de vidro, restaurado com Filtek Z350XT; 1pfv, 1 pino de fibra de vidro Exacto Nº 2 cimentado no canal distal com RelyX U200 restaurado com Z350XT; e 2pfv, 2 pinos de fibra de vidro Exacto Nº 2 cimentados com RelyX U200, um no canal distal e o outro no mesio-vestibular restaurado com Z350XT. As amostras foram submetidas à fadiga mecânica com carregamento axial de 50N. A deformação do remanescente foi mensurada usando extensômetros (n=10) durante o carregamento oclusal de 100N e em seguida até o momento de fratura. Os demais dentes (n=5) foram usados para calcular o módulo de elasticidade (E, GPa) e dureza Vickers (VH, N/mm2) do esmalte, dentina, resina composta e pino de fibra de vidro em duas posições: paralelamente e transversalmente ao longo eixo do pino. A distribuição de tensões foi analisada usando modelo tridimensional de elementos finitos gerado a partir de imagem de micro-CT de um dente hígido com medidas e geometrias representativo das amostras usadas na etapa experimental. Às propriedades mecânicas calculadas foram utilizadas para caracterizar os modelos da análise por elementos finitos. Os dados de deformação e resistência à fratura foram submetidos à teste de normalidade (Shapiro-Wilk) e equivalência de variâncias (teste de Levene), seguido por testes estatísticos paramétricos adequados para cada tipo de ensaio. Análise de variância em fator único foi realizada para os valores de resistência à compressão axial, deformação do remanescente e resistência à fratura. Comparações múltiplas foram realizadas usando teste de Tukey. Os dados de padrão de fratura foram submetidos ao teste Quiquadrado. Análise de variância fatorial em dois fatores foi realizada considerando como fatores em estudo: deformação da superfície do remanescente (V e L) e a técnica de reabilitação. Todos os testes empregados - 19 - tiveram nível de significância α=0,05 e todas as análises foram realizadas com o programa estatístico Sigma Plot versão 13.1 (Systat Software Ins, San Jose, CA, USA). O uso de dois pinos de fibra de vidro resultou em menor resistência à fratura que os grupos sem pino de fibra de vidro e com um pino de fibra de vidro. Durante o carregamento oclusal de 100N a superfície lingual do remanescente demonstrou maior deformação para todos os grupos. A ausência de pino de fibra de vidro resultou em valores significativamente mais elevados de tensões na dentina radicular e modos de fratura irreparáveis significativamente maiores que os outros grupos. O uso de um pino de fibra de vidro resultou em melhor razão deformação/resistência fratura. A concentração de tensão na área de furca foi ligeiramente reduzida com uso de pino de fibra de vidro. Conclui-se que o uso de um pino de fibra de vidro para reabilitar molares inferiores com resina composta direta mostrou maior resistência à fratura que o uso de dois pinos de fibra de vidro, menor deformação do remanescente, melhor distribuição de tensões e padrão de falha com maior número de fraturas reparáveis quando comparado a molares restaurados sem uso de pino de fibra de vidro / Mestre em Odontologia

Page generated in 0.0477 seconds