• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sociétés et identités du premier néolithique de Grande-Bretagne et d'Irlande : caractérisation et analyses comparatives des productions céramiques entre Manche, Mer d'Irlande et Mer du Nord / Societies and identities during early neolithic of Britain and Ireland in their West European context : characterization and comparative analysis of pottery productions between Channel, Irish Sea and North Sea

Pioffet, Hélène 10 December 2014 (has links)
Ce travail de thèse s'intègre dans le vaste débat de la néolithisation de la Grande-Bretagne et de l'Irlande (c. 4000 BC - 3500 BC). La question des liens entre les Îles Britanniques et le continent semblent aujourd'hui indéniables. Toutefois les modalités d'apparition et de développement du Néolithique sont, elles, encore mal connues. La présente étude porte sur l'analyse de la culture matérielle et plus particulièrement sur les productions céramiques, à partir d'un échantillonnage effectué à la fois en Grande-Bretagne, en Irlande, et sur le proche continent. Par ailleurs un pan analytique, jusqu'ici quelque peu délaissé dans les Îles Britanniques, a été mis à profit : l'étude technologique des productions céramiques. Deux interrogations majeures ont été formulées quant à l'arrivée et au développement des productions céramiques. La première concernait la détermination de styles de productions sur l'archipel et l'apparition d'identités culturelles liées à des traditions potières. La deuxième visait à identifier des aire(s) d'influences continentales à l'origine des productions de l'archipel. Les résultats obtenus, selon une approche multi-focale, tendent à illustrer deux grandes aires d'influences durant les premiers siècles du Néolithique (entre c. 4000 et 3700/3650 cal BC), d'une part sur la façade atlantique et l'ouest de la Manche, et d'autre part sur la façade de la Mer du Nord et l'est de la Manche. Ces grandes aires d'influences renseignent alors sur les modalités de néolithisation, vraisemblablement différentielles entre une façade occidentale et une façade orientale. Plus tard, les productions céramiques se régionalisent, développant des thèmes décoratifs pour certaines très élaborées (entre c. 3700/3650 et 3300/3200 cal BC) ; paradoxalement ces productions développent pour la plupart les mêmes codes stylistiques servant à les individualiser les unes des autres, mettant ainsi en exergue une nette accentuation des transferts de savoir-faire, à travers des réseaux d'échanges de plus en plus prégnants. / This Ph.D. thesis takes part to the vast debate of Mesolithic-Neolithic transition in Britain and Ireland. The bonds between the British Isles and the Near Continent are undeniable. Rather, the form(s) the transition took is (are) still to be understood. This work is an accurate analysis of material culture, more specifically pottery production ; sampling was made in order to address questions regarding Britain, Ireland and the Neat Continent. Moreover, a specific type of analysis, usually avoided in British studies, is here promoted : technological study of pottery production. This topic addressed the question of the determination of production styles as well as the appearing of cultural identities during that period. The second question that has been dealt with here is the continental areas of influence. The results obtained, following a multiscalar analysis, shed light on two wide areas during the first centuries of Neolithic (between c. 4000 and 3700/3650 cal BC), on the one hand on the Atlantic façade and western Channel and on the other hand on the North Sea façade and eastern Channel. These areas can thereafter inform on the transition modalities that, in all likelihood, are divergent from one area to the other. Later, pottery productions seem to find a regional basis, developing, for most of them, elaborate decorative patterns, probably used as a means of recognition. Interestingly, these productions seem to rely on the same stylistic codes that are used afterwards in the recognition process, highlighting the gradual emphasis on know-how transmission, through more and more significant exchange network.
2

Conception, réalisation et évaluation d'un implant diffractif bifocal intracornéen pour la correction de la presbytie / Design, elaboration and implementation of a diffractive bifocal intracorneal implant to correct presbyopia

Castignoles, Fannie 25 November 2011 (has links)
Actuellement, la presbytie peut être corrigée chirurgicalement à l’aide d’implants intraoculaires réfractifs ou diffractifs multifocaux (chirurgie endoculaire invasive et irréversible) ou en intracornéen avec une correction multifocale réfractive (correction laser irréversible, ou insertion d’un implant dans le stroma). L’objectif de ce travail est de développer un nouvel implant permettant de corriger la presbytie, qui allie l’innocuité et la réversibilité d’une correction intracornéenne, à l’efficacité du diffractif. Le design des profils optiques bifocaux a été permis grâce au développement d’outils de simulation optique. Les efficacités de diffraction sont calculées à partir de la propagation du champ électrique par spectre angulaire. La qualité optique est déterminée d’après les simulations de Fonction de Transfert de Modulation obtenues sous Zemax. Des simulations de rendu d’images permettent de visualiser les effets de différents profils envisagés. Les paramètres critiques du design optique sont déterminés. Le choix du matériau dépend des contraintes de biocompatibilité de l’implant et des techniques de fabrication. La solution retenue est un hydrogel à forte teneur en eau, couplé à une nouvelle architecture de l’implant. L’hydrogel est obtenu par polymérisation radicalaire de macromonomères difonctionnels de poly(éthylène glycol) de masses molaires de l’ordre de 8000 g.mol‐1 qui conduisent à des propriétés mécaniques et une perméabilité aux nutriments compatibles avec l’application. La réalisation, la stérilisation et la caractérisation optique de prototypes ont abouti à la preuve du concept d’un implant bifocal diffractif intracornéen / Presbyopia can be corrected with surgery by means of refractive or diffractive multifocal intraocular lenses (which imply an irreversible and invasive endocular surgery) or by intracorneal multifocal refractive correction (irreversible laser correction, or insertion of an intrastromal implant). This work aims at developing a new implant to correct presbyopia, which takes advantage of both the harmlessness and the reversibility of an intracorneal correction, and the efficiency of diffractive optics. The design of the bifocal optical profiles was based on the development of optical simulation tools. The diffractive efficiencies are calculated from the distribution of the electric field with the method of angular spectrum. The optical quality is determined according to the simulations of Modulation Transfer Function obtained with Zemax. Images simulations show the effects of the different profiles studied. The critical parameters of the optical design are also determined. The choice of the material depends on several constraints such as biocompatibility and techniques of manufacturing. The adopted solution relies on the used of an hydrogel with high water content and the design of a new implant architecture. The hydrogel is obtained by radical polymerization of difunctional macromonomers of poly(ethylene glycol) with molar masses around 8000 g.mol‐1, allowing mechanical properties and permeability to nutriments compatible with the application. The realization, the sterilization and the characterization of prototypes showed the proof of the concept of a diffractive bifocal intracorneal implant

Page generated in 0.0339 seconds