• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2312
  • 603
  • 320
  • 318
  • 305
  • 144
  • 73
  • 42
  • 38
  • 37
  • 29
  • 19
  • 18
  • 15
  • 12
  • Tagged with
  • 5438
  • 661
  • 552
  • 537
  • 502
  • 461
  • 428
  • 409
  • 332
  • 312
  • 311
  • 301
  • 293
  • 274
  • 267
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1491

Vortex shedding-induced noise reduction using (DBD) plasma actuator

Al-Sadawi, Laith Ayad January 2018 (has links)
The Dielectric Barrier Discharge (DBD) plasma actuators have received a significant attention of many researchers in the last few decades. The main focus of these studies has been on the flow control areas such as turbulent boundary layer separation and turbulent skin friction reduction. Little attention has been paid on the effect of the DBD plasma actuators on the aerodynamic noise reduction. In this regard, the aim of the current work is to investigate the effect of the DBD plasma actuator driven at relatively low voltages on vortex-induced noise. The first part of the current work includes an extensive assessment of the effect of the DBD plasma actuator on the narrowband tonal noise radiated from a flat plate with blunt trailing edge and an airfoil (NACA 0012) with blunt and cut-in type serrated trailing edge. The measurements were carried out at Reynolds numbers between 0.75 x 10 to the power of 5 and 4 x 10 to the power of 5. It is found that the DBD plasma actuator effectiveness depends on the direction of the generated electric wind. For example, a high reduction in the narrowband tonal noise level is achieved when a direct streamwise electric wind is injected into the wake region. However, using a plasma actuator, which can induce streamwise vortices into the wake region, shows more superior noise reduction capability at lower voltages. Flow measurement results revealed that the mechanism responsible for the narrowband tonal noise reduction when the electric wind is directly injected into the wake is not due the momentum injection into the wake deficit. Rather, the streamwise jet isolates the two separated shear layers and prevents the interaction between them. On the other hand, it is found that the break-up of the spanwise coherence of the vortex shedding is responsible for the significant reduction in the tonal noise level when the spanwise actuation is used. The second part of the current work comprises the effect of the DBD plasma actuator on both the narrowband tonal noise and interaction broadband noise radiated from both single and tandem cylinder, respectively. The experiments were conducted at subcritical Reynolds number ReD = 1.1 x 10 to the power of 4. The actuators were positioned at different azimuthal angles 27° ≤ θj ≤ 153°. For the single cylinder case, the acoustic results show the DBD plasma actuator that is positioned at θj = 133° leads to a more reduction in the narrowband tonal noise level when compared to the other angles. It is found that the streamwise jet produced by the plasma actuators plays an important role in prevention of the interaction between the shear layers that separates from the cylinder. For the tandem cylinders case, the acoustic results show that the simultaneous actuation of both the upstream and the downstream cylinders leads to more reduction in both the narrowband tonal noise and the interaction broadband noise level compared with the case where only the upstream or the downstream cylinder is actuated. The mechanism responsible for this noise reduction is found to be mainly due to the streamwise jet induced by the upstream cylinder activation, which delays the vortex shedding formation and reduces the turbulence intensity in the near wake region. On the other hand, the plasma induced jet against the main-flow direction works as a virtual fluidic barrier which displaces the wake produced by the upstream cylinder away from the downstream cylinder.
1492

Avaliação das variações na força de atrito de materiais de fricção utilizando um tribômetro

Moraes, Tiago Roberto Borges de January 2016 (has links)
A demanda crescente por veículos mais confortáveis e mais seguros apresenta desafios à indústria. Os freios são um dos mais importantes sistemas de segurança dos veículos e também são frequentemente objeto de reclamações de consumidores por motivo de ruído. Os materiais de atrito empregados nos sistemas de freio devem apresentar desempenho satisfatório sob diferentes condições de temperatura e umidade, possuindo resistência à corrosão, longa vida útil, baixo custo e produzindo baixos níveis de ruído. Com o objetivo de caracterizar diferentes materiais quanto ao coeficiente de atrito e à produção de ruído, foram realizados ensaios de frenagem em diferentes condições utilizando um tribômetro. Esse equipamento possui sistemas de medição e controle capazes de registrar os coeficientes de atrito a cada frenagem simulada. O tribômetro também foi instrumentado com uma célula de carga capaz de medir variações da força de atrito. Os ensaios foram realizados em diferentes condições de temperatura e de intervalos de tempo entre as frenagens, alternando etapas quentes e frias. Durante o assentamento dos materiais, foram verificados diferentes comportamentos do coeficiente de atrito. Os materiais ensaiados apresentaram sensibilidade às variações de temperatura e de intervalos de tempo entre frenagens. Foi observada correlação entre as variações da força de atrito e o coeficiente de atrito. Também foram evidenciados os efeitos da velocidade de deslizamento sobre o espectro de frequências de variação da força de atrito. / The growing demand for more comfortable and safer vehicles comes up with new challenges to the industry. The brakes are one of the most important vehicle safety systems and are also often the subject of customer complaints about noise. The brake friction materials need to perform properly under different conditions of temperature and humidity, presenting resistance to corrosion, long life, low cost and producing low noise levels. In order to characterize the friction coefficient and noise generation of different friction materials, different conditions were tested using a tribometer. This equipment has measurement and control systems capable of record each brake stop friction coefficient. The tribometer was also instrumented with a load cell capable of measuring friction force variations. The tests were performed at different temperatures and time intervals between brake applications, alternating hot and cold stages. During the materials running-in, different behaviors of the friction coefficients were found. The friction materials tested showed sensitivity to temperature variations and time intervals between brake applications. There was a correlation between friction force variations and coefficient of friction. There were also effects of the slip speed on the frequency spectrum of the frictional force variations.
1493

Saúde auditiva em frequentadores de ginásio de esportes: mensuração do nível de pressão sonora e avaliação audiológica / The hearing health of gyms attendees: sound pressure measuring and audiologic evaluation

Ferreira, Nelfa Souza 10 November 2014 (has links)
O ruído faz-se cada vez mais onipresente no cotidiano de toda sociedade e a exposição continuada a elevados Níveis de Pressão Sonora (NPS), dentre outros danos, pode originar uma Perda Auditiva Induzida por Níveis de Pressão Sonora Elevados (PAINPSE): lesão auditiva irreversível, que interfere na qualidade de vida do sujeito acometido, podendo ser ocasionada tanto pela exposição ocupacional, quanto pela não ocupacional. E, o ginásio de esportes figura como um ambiente propício à exposição de tal natureza, onde coexistem esses dois tipos. A proposição deste estudo foi investigar a exposição sonora e a saúde auditiva de esportistas e não esportistas que frequentam ginásios de esportes. Participaram deste, 25 indivíduos frequentadores de um ginásio de esportes, divididos em três grupos: nove jogadores (G I), oito integrantes do público (G II) e oito funcionários do local (G III). Todos foram submetidos ao questionário específico e às avaliações auditivas (Imitanciometria, Audiometria Tonal Liminar AT-AC e de Altas Frequências AT-AF) e, além disso, foram obtidas em dois momentos (jogo oficial e jogo treino), mensurações de intensidade sonora no ginásio. Como resultados, tais mensurações no jogo oficial variaram de 73,3 e 112 dBNPS(A) e no jogo treino, de entre 70,8 e 100,1 dBNPS(A). Ao questionário específico, os sintomas auditivos mais referidos foram otalgia (55,6% do GI), zumbido (37,5% do GII) e hiperacusia (37,5% do GIII); para os não auditivos, obtiveram maiores prevalências cefaleia (44,4% GI), e alteração do sono (50% do GII e 37,5% do GIII); após exposição a elevados NPS, o sintoma auditivo mais referido foi hiperacusia (25% do GII e do GIII); para os não auditivos, obtiveram maiores prevalências alteração do sono (66,7% do GI) e cefaleia (50% do GII). Nas avaliações auditivas, a imitanciometria indicou a curva timpanométrica do Tipo A como mais recorrente (100% OD e OE no GI; 62,5% OD e 87,5% OE no GII; 75% OD e 87,5% OE no GIII) e o GI foi o único que obteve 100% de presença de reflexos ipsilaterais (bilateralmente) e contralaterais com aferência em OD; a AT-AC apontou a frequência de 6 kHz como a mais acometida, bilateralmente. Na comparação entre médias tritonais (0,5, 1 e 2 kHz com 3, 4 e 6 kHz), houve diferença estatisticamente significante apenas no GIII, em OE; a AT-AF apontou as frequências de 12,5 kHz na OD e 14 kHz na OE como as mais acometidas. Na comparação entre as médias dos limiares entre os três grupos, houve diferença estatisticamente significante apenas para as frequências de 11,2 e 12,5 kHz. Evidenciou-se que na mensuração do NPS, para todos os pontos e em ambos momentos, foram obtidos valores que ultrapassaram os estabelecidos em pelo menos uma das normas utilizadas neste estudo. Para G II e G III, verifica-se ainda o indício de comprometimento de células ciliadas externas, retratado pela normalidade das médias dos limiares tonais convencionais, acompanhada de ausência de respostas na AT-AF. Nesse sentido, destaca-se como relevante a adoção de medidas que viabilizem a conservação da saúde auditiva dos frequentadores do ambiente esportivo ginásio de esportes. / Noise has become more and more omnipresent in the routine of society and the continued exposure to elevated Sound Pressure Levels (SPL), among other damages, may cause Noise Induced Hearing Loss (NIHL): an irreversible hearing damage, which interferes in the subjects quality of life, and is caused both by occupational exposure and by non-occupational exposure. The gyms configures a propitious environment to exposures of such nature, where these two types coexist. The purpose of this study was to investigate the sound exposure and the hearing care of sports players and non sports players who attend gyms. 25 individuals, attendees of gym, participated of this study: nine players (G I), eight publics members (G II) and eight gyms employees (G III). All of them were subject to the specific questionnaire and to the hearing evaluations (Immitanciometry, Pure Tone Audiometry, and High-Frequency Audiometry) and, besides, two sound intensity measurements were obtained in the gym (official game and training game). The results indicate that such measurements in the official game varied from 73,3 to 112 dBSPL(A) and in the training game, from 70,8 to 100,1 dBSPL(A). According to the specific questionnaire the most felt hearing symptoms were otalgy (55,6% of G I), tinnitus (37,5% of G III); in the non-hearing symptoms the most frequent were headaches ( 44,4% of G I) and sleeping alteration ( 50% of G II and 37,5% of G III); after exposure to elevated SPL, the most mentioned hearing symptom was hyperacusis (25% of GII and G III); in the non-hearing symptoms prevailed sleeping alteration (66,7% of GI) and headache (50% of GII). In the hearing evaluations, the Immitanciometry indicated the tympanometric curve of the Type A as more recurrent (100% RE and LE in GI; 62,5% RE and 87,5% LE in GII; 75% RE and 87,5 LE in GIII) and the GI was the only one that obtained 100% presence of ipsilateral reflexes (bilaterally) and contralateral with RE checking, the PTA pointed the frequency of 6khz as the most affected, bilaterally. In the comparison between tritonal averages (0,5, 1 and 2 kHz with 3, 4 and 6 kHz) there was a statistically significant difference only in the GIII, in LE; the HFA pointed the frequencies of 12,5 kHz in the RE and 14kHz in the LE as the most affected. In the averages comparison between the threshold of the three groups, there were a significant statistically difference only to the frequencies of 11,2 and 12,5 kHz. It was evident that in the measuring of SPL, to all the points and in both moments, there were obtained values that exceeded the established in at least one of the norms used in this study. To GII and GII there was also verified the impairment of external ciliated cells, portrayed by the normality conventional tonal thresholds, followed by the absence of answers in the HFA. In this sense, we highlight the relevance of adopting measures that make the conservation of the gym attendees hearing health possible.
1494

Active noise attenuation

Short, William Rhuel January 1980 (has links)
Thesis (Sc.D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1980. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING. / Vita. / Bibliography: leaves 121-123. / by William Rhuel Short. / Sc.D.
1495

Saúde auditiva em frequentadores de ginásio de esportes: mensuração do nível de pressão sonora e avaliação audiológica / The hearing health of gyms attendees: sound pressure measuring and audiologic evaluation

Nelfa Souza Ferreira 10 November 2014 (has links)
O ruído faz-se cada vez mais onipresente no cotidiano de toda sociedade e a exposição continuada a elevados Níveis de Pressão Sonora (NPS), dentre outros danos, pode originar uma Perda Auditiva Induzida por Níveis de Pressão Sonora Elevados (PAINPSE): lesão auditiva irreversível, que interfere na qualidade de vida do sujeito acometido, podendo ser ocasionada tanto pela exposição ocupacional, quanto pela não ocupacional. E, o ginásio de esportes figura como um ambiente propício à exposição de tal natureza, onde coexistem esses dois tipos. A proposição deste estudo foi investigar a exposição sonora e a saúde auditiva de esportistas e não esportistas que frequentam ginásios de esportes. Participaram deste, 25 indivíduos frequentadores de um ginásio de esportes, divididos em três grupos: nove jogadores (G I), oito integrantes do público (G II) e oito funcionários do local (G III). Todos foram submetidos ao questionário específico e às avaliações auditivas (Imitanciometria, Audiometria Tonal Liminar AT-AC e de Altas Frequências AT-AF) e, além disso, foram obtidas em dois momentos (jogo oficial e jogo treino), mensurações de intensidade sonora no ginásio. Como resultados, tais mensurações no jogo oficial variaram de 73,3 e 112 dBNPS(A) e no jogo treino, de entre 70,8 e 100,1 dBNPS(A). Ao questionário específico, os sintomas auditivos mais referidos foram otalgia (55,6% do GI), zumbido (37,5% do GII) e hiperacusia (37,5% do GIII); para os não auditivos, obtiveram maiores prevalências cefaleia (44,4% GI), e alteração do sono (50% do GII e 37,5% do GIII); após exposição a elevados NPS, o sintoma auditivo mais referido foi hiperacusia (25% do GII e do GIII); para os não auditivos, obtiveram maiores prevalências alteração do sono (66,7% do GI) e cefaleia (50% do GII). Nas avaliações auditivas, a imitanciometria indicou a curva timpanométrica do Tipo A como mais recorrente (100% OD e OE no GI; 62,5% OD e 87,5% OE no GII; 75% OD e 87,5% OE no GIII) e o GI foi o único que obteve 100% de presença de reflexos ipsilaterais (bilateralmente) e contralaterais com aferência em OD; a AT-AC apontou a frequência de 6 kHz como a mais acometida, bilateralmente. Na comparação entre médias tritonais (0,5, 1 e 2 kHz com 3, 4 e 6 kHz), houve diferença estatisticamente significante apenas no GIII, em OE; a AT-AF apontou as frequências de 12,5 kHz na OD e 14 kHz na OE como as mais acometidas. Na comparação entre as médias dos limiares entre os três grupos, houve diferença estatisticamente significante apenas para as frequências de 11,2 e 12,5 kHz. Evidenciou-se que na mensuração do NPS, para todos os pontos e em ambos momentos, foram obtidos valores que ultrapassaram os estabelecidos em pelo menos uma das normas utilizadas neste estudo. Para G II e G III, verifica-se ainda o indício de comprometimento de células ciliadas externas, retratado pela normalidade das médias dos limiares tonais convencionais, acompanhada de ausência de respostas na AT-AF. Nesse sentido, destaca-se como relevante a adoção de medidas que viabilizem a conservação da saúde auditiva dos frequentadores do ambiente esportivo ginásio de esportes. / Noise has become more and more omnipresent in the routine of society and the continued exposure to elevated Sound Pressure Levels (SPL), among other damages, may cause Noise Induced Hearing Loss (NIHL): an irreversible hearing damage, which interferes in the subjects quality of life, and is caused both by occupational exposure and by non-occupational exposure. The gyms configures a propitious environment to exposures of such nature, where these two types coexist. The purpose of this study was to investigate the sound exposure and the hearing care of sports players and non sports players who attend gyms. 25 individuals, attendees of gym, participated of this study: nine players (G I), eight publics members (G II) and eight gyms employees (G III). All of them were subject to the specific questionnaire and to the hearing evaluations (Immitanciometry, Pure Tone Audiometry, and High-Frequency Audiometry) and, besides, two sound intensity measurements were obtained in the gym (official game and training game). The results indicate that such measurements in the official game varied from 73,3 to 112 dBSPL(A) and in the training game, from 70,8 to 100,1 dBSPL(A). According to the specific questionnaire the most felt hearing symptoms were otalgy (55,6% of G I), tinnitus (37,5% of G III); in the non-hearing symptoms the most frequent were headaches ( 44,4% of G I) and sleeping alteration ( 50% of G II and 37,5% of G III); after exposure to elevated SPL, the most mentioned hearing symptom was hyperacusis (25% of GII and G III); in the non-hearing symptoms prevailed sleeping alteration (66,7% of GI) and headache (50% of GII). In the hearing evaluations, the Immitanciometry indicated the tympanometric curve of the Type A as more recurrent (100% RE and LE in GI; 62,5% RE and 87,5% LE in GII; 75% RE and 87,5 LE in GIII) and the GI was the only one that obtained 100% presence of ipsilateral reflexes (bilaterally) and contralateral with RE checking, the PTA pointed the frequency of 6khz as the most affected, bilaterally. In the comparison between tritonal averages (0,5, 1 and 2 kHz with 3, 4 and 6 kHz) there was a statistically significant difference only in the GIII, in LE; the HFA pointed the frequencies of 12,5 kHz in the RE and 14kHz in the LE as the most affected. In the averages comparison between the threshold of the three groups, there were a significant statistically difference only to the frequencies of 11,2 and 12,5 kHz. It was evident that in the measuring of SPL, to all the points and in both moments, there were obtained values that exceeded the established in at least one of the norms used in this study. To GII and GII there was also verified the impairment of external ciliated cells, portrayed by the normality conventional tonal thresholds, followed by the absence of answers in the HFA. In this sense, we highlight the relevance of adopting measures that make the conservation of the gym attendees hearing health possible.
1496

PoluiÃÃo sonora na escola:perceber, apreciar, conscientizar e reciclar sons para musicalizar / Noise pollution in school: realize, appreciate, awareness and recycle sounds to musicalizar

Deise da Costa Crispim 15 July 2016 (has links)
O presente trabalho, representado por uma Proposta PedagÃgica, toma como objeto de estudo a educaÃÃo musical, no que se refere especificamente à musicalizaÃÃo, tendo como ponto de partida a poluiÃÃo sonora. Para tanto, expÃe, reflete, relata e propÃe atividades relacionadas ao assunto, utilizando-o como recurso de percepÃÃo, apreciaÃÃo, conscientizaÃÃo e aprendizagem musical, por meio dos sons. Com isso, aborda questÃes relevantes acerca da paisagem sonora, trazendo educadores musicais, tais como Schafer, Swanwick e Fonterrada, que dialogam e refletem sobre o processo de ensino aprendizagem da mÃsica. Concomitantemente, esse estudo apresenta um relato de experiÃncia do ensino de mÃsica nas escolas municipais Professor Berilo Wanderley e EmÃlia Ramos, no municÃpio de Natal, Rio Grande do Norte, a partir da poluiÃÃo sonora, representada diferentemente em cada uma delas. As experiÃncias vivenciadas, bem como as atividades desenvolvidas nesta proposta pedagÃgica, foram obtidas por meio de um projeto de pesquisa, numa abordagem qualitativa, na qual se utilizou materiais como gravaÃÃes, filmagens, entrevistas de sondagem, atividades musicais teÃricas e prÃticas, dinÃmicas, dentre outros recursos pedagÃgicos, para construÃÃo e obtenÃÃo dos dados comprobatÃrios aqui descritos. / This work is represented by a pedagogical proposal and takes music education as object of study, as far as musicalization is concerned, and it also takes noise pollution as its starting point. For this reason, this work exposes, reflects, reports and proposes activities related to the subject, using it as a tool of perception, appreciation, awareness and music learning by means of sounds. It addresses relevant questions about the soundscape by bringing music educators, such as Schafer, Swanwick and Fonterrada, and by dialoguing and reflecting on the process of music teaching and learning. Concurrently, this work brings an account of music teaching in the following municipal schools: Professor BeriloWanderley and Professora Emilia Ramos, in Natal, Rio Grande do Norte. The starting point of this account was the noise pollution, which was represented differently in each municipal school. The experiences and activities developed in this pedagogical proposal were obtained by means of a research project, in a qualitative approach in which materials such as recordings, films, interviews, theoretical musical activities and practices, dynamics were broadly used, among other teaching resources designed to construct and obtain corroborative data described herein.
1497

Incômodo em relação ao ruído urbano entre trabalhadores de estabelecimentos comerciais no município de São Paulo / Annoyance related about urban noise among workers of commercial establishments in the city of Sao Paulo, Brazil

Andréa Petian 10 October 2008 (has links)
Objetivos: 1) Estimar a prevalência do incômodo causado pelo ruído em trabalhadores de estabelecimentos comerciais no município de São Paulo. 2) Identificar o conhecimento e a opinião dos trabalhadores de estabelecimentos comerciais em relação ao ruído urbano 3) Identificar fatores sócio-demográficos associados ao incômodo, ao conhecimento e a opinião em relação ao ruído urbano. Métodos: Estudo transversal com 400 trabalhadores de estabelecimentos comerciais situados na zona central do município de São Paulo. O instrumento utilizado foi um questionário que contemplava questões sobre dados sócio-ambientais, ruído e aspectos relacionados aos incômodos por ele causados. As entrevistas foram realizadas no próprio estabelecimento onde o trabalhador atuava, em horário comercial. Mediu-se também o nível de pressão sonora no posto de trabalho, em um estabelecimento de cada rua visitada. Resultados: Dos 400 participantes, 59% eram do sexo feminino. A idade dos indivíduos variou entre 18 e 89 anos, com a mediana de 31 anos. 60% tinham nível escolar médio completo ou incompleto, 46% eram do setor de moda e 44% exerciam a função de balconista. Espontaneamente o ruído aparece em quarto colocado em incômodos no município e em primeiro em incômodo no local de trabalho e na residência. Do total, 65,75% achavam o local de trabalho ruidoso e 62,5% se mostraram incomodados com ruído neste local. O ruído interferia na atividade laboral de 43% dos trabalhadores sendo que a principal falar ao telefone (54%). Os principais problemas causados ou agravados pelo ruído, na opinião dos trabalhadores foram: perda auditiva, (72%), estresse (29%), irritabilidade (9%), dor de cabeça (7%), nervosismo (3%) e alterações do sono (1%). A maioria dos entrevistados referiu ter boa audição (96%). O sexo masculino e o maior nível de escolaridade se mostraram associados ao fato do trabalhador referir que o local de trabalho era ruidoso. Conclusões: A prevalência de trabalhadores que trabalhavam em estabelecimentos comerciais no município de São Paulo que referiram incômodo relacionado ao ruído no local de trabalho foi estimada em 62,5%. Referiram que o local de trabalho era ruidoso 65,75% trabalhadores e, o ruído do tráfego no local de trabalho incomodou 62% trabalhadores. Com os resultados deste estudo pode-se inferir que os trabalhadores conheciam tanto o risco físico do ruído, quanto o incômodo que ele pode causar. Os trabalhadores relataram que o ruído poderia causar ou agravar alguns problemas de saúde, principalmente a perda auditiva, estresse e irritabilidade / Objectives: 1) To evaluate the annoyance caused by noise among workers of commercial establishments of the city o Sao Paulo. 2) To find out the knowledge and opinion of these workers about the urban noise. 3) To identify socio-demographic factors associated to the annoyance, the knowledge and the opinion of the workers of commercial establishments in the city of Sao Paulo about the urban noise. Methods: This is a cross sectional study with 400 workers of commercial establishments located at the central area of the city of Sao Paulo. It was used a questionnaire that included questions about socio-environmental, noise and aspects related to the annoyances caused by them. The interviews were carried on at the workers workplace, during working hours. It was also measured the noise level at the workstation in one establishment of every street visited. Results: Of the 400 participants, 59% were female. The age ranged from 18 and 89 years old, with a median of 31 years. 60% of them had complete or incomplete high school educational level, 46% worked with clothes, and 44% were clerks. Noise appears spontaneously in fourth place among the annoyances at the workplace and at home. Of the participants 65.75% considered the workplace noisy, and 62.5% declared the felt annoyed by the noise at this place. Noise interfered with the professional activities of 43% of the workers, being talking to the phone the main activity disrupted (54%). Main problems caused or worsened by noise, for the workers, were: hearing loss (72%), stress (29%), irritability (9%), headache (7%), nervousness (3%), and sleep disturbances (1%). Most of the interviewed workers consider themselves as having a good hearing (96%). Male gender and higher schooling level were associated to the fact the worker mentions the workplace is noisy. Conclusions: The prevalence of people working at commercial establishments in the city of Sao Paulo who mentioned annoyance related to noise at the workplace was estimated to be 62.5%. 65.75% of the workers mentioned that the workplace was noisy, and the traffic noise was disturbing for 62% of the workers. From the results of this study it can inferred that the workers knew the physical risks associated to noise and the annoyances it can cause. The workers mentioned that noise could cause or worsen some health problems, especially hearing loss, stress and irritability
1498

Detecção e avaliação de impactos em mecanismos de direção automotivo servo-assistido através do uso da Transformada de Wavelets. / Impacts detection and evaluation of steering system with servo assistance by the use of Wavelet Transform.

Marcos Jun Tsuchie 27 October 2010 (has links)
Sabe-se que folgas e impactos de partes internas reduzem o desempenho da transmissão, do sistema de controle e a qualidade global do mecanismo. Folgas causam instabilidade, mas impactos também geram ruídos estruturais que perturbam medições e causam ruído acústico que reduz o conforto. Sinais de movimento são frequentemente usados para realimentação e podem ser perturbados por ruídos de impacto. Para avaliar este problema, um procedimento capaz de detectar e quantificar a severidade e a frequência de ocorrência de impactos é proposto. Desta forma, o desempenho de diferentes sistemas em relação à sua robustez ao impacto pode ser comparado. Sinais de vibração na estrutura do sistema são medidos e o sinal é processado digitalmente e decomposto em múltiplas escalas pela Transformada de Wavelet. As wavelets Harmônicas e de Daubechies são comparadas. Escalas que correspondem aos níveis de detalhamento característicos dos impactos são extraídas do sinal de vibração e a severidade do impacto é avaliada. Após o processamento do sinal e a retirada do ruído, o sinal original é disponibilizado para posterior processamento e controle. Foi estudado o ruído de impacto em caixas de direção conhecido como knock noise. Ao final, tentou-se comparar a técnica de Transformada de Wavelet com a técnica de Emissão Acústica. Na sessão Transformada de Wavelets é feito um breve estudo de alguns conceitos necessários para o entendimento de wavelets e é explicada a técnica utilizada para a detecção dos ruídos de impacto. Na sessão Emissão Acústica é explicada a técnica utilizada para comparar com a técnica de wavelets. Na sessão Direção Hidráulica é explicado o mecanismo de direção estudado. Na sessão Resultados, são mostrados os sinais de ruídos de impacto detectados pela Transformada de Wavelet e Emissão Acústica e o método adotado para mensurar a severidade dos impactos e a frequência de ocorrência dos mesmos. / It is well known that backlash and impact of inner parts reduce the performance of transmission, control systems and overall quality of mechanism. Clearance causes instability, but impact also generates structural borne noise that disrupts measurements and cause acoustic noise that reduces the comfort. Motion signals are often used for feedback and can be disrupted by impact noise. In order to overcome this problem a procedure able to detect and quantify the severity and rate of occurrence of impacts is proposed. Thence performance of different systems in regard to their robustness to impact can be compared. A procedure to detect and evaluate impacts of inner parts of mechanical mechanism is presented. Therefore, vibration signals on the structure of the system are measured and the signal is digitally processed and decomposed into multiscales by the Wavelet transform. Both Daubechies and Harmonic Wavelet are compared. Scales that correspond to the impact response are extracted from the overall vibration signal, and the impact severity is rated. After signal processing and de-noising, the original signal without the impact is also available for further processing and control. The analysis technique was applied to study the impact noise in steering boxes known as knock noise. Finally, it was tried to compare the technique of wavelet transform with the Acoustic Emission. First, a brief study is presented of some concepts necessary to understand wavelets and Wavelet Transform technique is explained and the approach used for detection of impact noise is presented. In the following section the technique of Acoustic Emission is explained and how it was compared to the wavelet technique. The Hydraulic Steering System is explained in the next section. In the final section the Results of the study are show, the signal with impact noise, the impact detected by the Wavelet Transform and Acoustic Emission and the method used to measure the severity of impacts and to measure the frequency of their occurrence.
1499

Avaliação da percepção da fala com ruído competitivo em adultos com implante coclear. / Evaluation of speech perception in noise in cochlear implanted adults.

Leandra Tabanez do Nascimento 06 February 2002 (has links)
Os objetivos deste trabalho foram: avaliar os efeitos das diferentes relações sinal/ruído, no reconhecimento da fala com o implante coclear; comparar o reconhecimento da fala no ruído, com diferentes tipos de implantes cocleares multicanais; avaliar a influência do tempo de surdez, tempo de uso do implante coclear e progressão da surdez, no reconhecimento da fala com o implante coclear e avaliar o grau de dificuldade dos usuários de implante coclear, em situações com ruído competitivo no dia-a-dia. Foram selecionados 40 adultos com deficiência auditiva pós-lingual, com os implantes cocleares Nucleus 22 (N=13, estratégia SPEAK), Nucleus 24 (N=7, estratégia ACE), Combi 40 (N=6), Combi 40+ (N=7) e Clarion (N=7) com a estratégia CIS, com experiência de mais 6 meses de uso do implante coclear e reconhecimento de fala em conjunto aberto. Foi avaliado o reconhecimento das sentenças CPA (Valente 1998), no silêncio e nas relações S/R de +15 dB, +10 dB, +5 dB e aplicado o questionário Social Hearing Handicap Index - SHHI (Wedel e Tegtmeier 1979, Wedel 1983), para a auto-avaliação do desempenho com o implante coclear, em situações de silêncio (componente da deficiência auditiva) e ruído (componente da seletividade), no dia-a-dia. Os usuários de todos os tipos de implante coclear apresentaram redução significativa dos índices de reconhecimento de sentenças CPA, em função da diminuição da relação S/R, com a curva das medianas de reconhecimento das sentenças CPA alcançando 50% na relação S/R de +10 dB. Não houve diferença estatisticamente significante nos índices de reconhecimento das sentenças CPA e escores de dificuldade do Social Hearing Handicap Index (SHHI), obtidos com os diferentes tipos de implantes cocleares e estratégias de codificação da fala. As dificuldades dos usuários de implante coclear foram raras nas situações de silêncio (componente da deficiência auditiva) e ocasionais nas situações com ruído competitivo (componente da seletividade), no questionário SHHI. Observou-se, também, a influência das características dos sujeitos (tempo de surdez, tempo de uso do implante coclear e progressão da surdez) nos índices de reconhecimento das sentenças CPA. O presente estudo permitiu concluir que os usuários de todos o tipos de implante coclear multicanais apresentaram redução dos índices de reconhecimento da fala, em função da diminuição da relação S/R e maior dificuldade, no dia-a-dia, em ambientes com ruído competitivo, do que no silêncio. / The aims of this study were: to evaluate the effects of different signal to noise ratios on speech recognition obtained by the use of the cochlear implant; to compare the speech recognition in noise with different types of multichannel cochlear implants; to evaluate the influence of duration of deafness, time of implant use and hearing loss progression in the speech recognition with cochlear implant and to evaluate the degree of difficulty for speech understanding in noise in daily life situations as well. Forty adults with post lingual hearing loss implanted with Nucleus 22 (n=13, SPEAK strategy), Nucleus 24 (n=7, ACE strategy), Combi 40 (n=6, CIS strategy), Combi 40+ (n=7, CIS strategy) and Clarion (n=7, CIS strategy). The minimum time of implant use was 6 months. All subjects enjoyed some degree of open set recognition. It was evaluated the recognition for CPA sentences (Valente 1998), in silence and in S/N +15, +10 and +5 dB. It was also applied the Social Hearing Handicap Index - SHHI questionnaire (Wedel e Tegtmeier 1979, Wedel 1983) for self assessment in daily life in silence (hearing loss component) and noise (selectivity component). All the implanted adults presented a significant reduction in the scores for sentences recognition as the S/N decreased. The medians´ curve for sentence recognition reached 50% in the signal to noise ratio of +10 dB. There was no difference statistically significant in sentences recognition scores and difficulty scores obtained with the Social Hearing Handicap Index (SHHI), for all types of implants and different speech strategy. The difficulties of implanted adults were rare in silence (hearing loss component) and occasional in noisy situations (selectivity component) in the SHHI questionnaire. It was also observed the influence of duration of deafness, time of implant use and hearing loss progression in the sentences recognition scores. In this study it was concluded that all subjects presented a significant reduction in sentences recognition scores as the S/N decreased and all subjects showed more difficulty for speech understanding in noisy environments independently of the type of multichannel cochlear implants used.
1500

Broken Ergodicity and $1/f$ Noise from Finite, Local Entropy Baths

January 2018 (has links)
abstract: Fluctuations with a power spectral density depending on frequency as $1/f^\alpha$ ($0<\alpha<2$) are found in a wide class of systems. The number of systems exhibiting $1/f$ noise means it has far-reaching practical implications; it also suggests a possibly universal explanation, or at least a set of shared properties. Given this diversity, there are numerous models of $1/f$ noise. In this dissertation, I summarize my research into models based on linking the characteristic times of fluctuations of a quantity to its multiplicity of states. With this condition satisfied, I show that a quantity will undergo $1/f$ fluctuations and exhibit associated properties, such as slow dynamics, divergence of time scales, and ergodicity breaking. I propose that multiplicity-dependent characteristic times come about when a system shares a constant, maximized amount of entropy with a finite bath. This may be the case when systems are imperfectly coupled to their thermal environment and the exchange of conserved quantities is mediated through their local environment. To demonstrate the effects of multiplicity-dependent characteristic times, I present numerical simulations of two models. The first consists of non-interacting spins in $0$-field coupled to an explicit finite bath. This model has the advantage of being degenerate, so that its multiplicity alone determines the dynamics. Fluctuations of the alignment of this model will be compared to voltage fluctuations across a mesoscopic metal-insulator-metal junction. The second model consists of classical, interacting Heisenberg spins with a dynamic constraint that slows fluctuations according to the multiplicity of the system's alignment. Fluctuations in one component of the alignment will be compared to the flux noise in superconducting quantum interference devices (SQUIDs). Finally, I will compare both of these models to each other and some of the most popular models of $1/f$ noise, including those based on a superposition of exponential relaxation processes and those based on power law renewal processes. / Dissertation/Thesis / Doctoral Dissertation Physics 2018

Page generated in 0.0593 seconds