• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 19
  • 19
  • 19
  • 11
  • 11
  • 7
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação da técnica de MQL combinado com ar resfriado (CAMQL) na retificação do aço ABNT 4340 com rebolo de CBN /

Fragoso, Kamira Miksza. January 2017 (has links)
Orientador: Eduardo Carlos Bianchi / Banca: Luiz Eduardo de Angelo Sanchez / Banca: Leonardo Roberto da Silva / Resumo: O processo de retificação é um processo de acabamento, e, portanto, possui características como bom acabamento superficial e alta precisão dimensional e geométrica. As peças usinadas por este processo possuem um alto valor agregado, pois as mesmas já passaram por outros processos de usinagem e/ou tratamentos térmicos e revenimento. Um fator limitador do processo de retificação é a quantidade de calor gerada durante o mesmo, energia esta que é minimizada pela aplicação de fluidos de corte durante a retificação. Porém os fluidos utilizados, na maior parte dos casos são poluentes e contém substâncias prejudiciais à saúde, além de possuir um alto custo de compra, manutenção e descarte. Visando reduzir a quantidade de fluido utilizada durante o processo de retificação o presente trabalho foi proposto, com o objetivo de melhorar a técnica da mínima quantidade de lubrificação através da aplicação combinada com ar comprimido à baixa temperatura a fim de melhorar o efeito de refrigeração e assim minimizar a geração de calor na região de corte. Para avaliar a eficácia da técnica foram escolhidas as variáveis de acabamento como a rugosidade e a circularidade, e de eficiência do processo como o desgaste do rebolo e potência consumida durante a usinagem. Estes valores foram medidos para três métodos distintos de aplicação de fluidos de corte durante o processo de retificação, a fim de compará-los, o método proposto para o presente trabalho, CAMQL (técnica de mínima quantidade de fluido co... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Grinding is a finishing process, and therefore has characteristics such as good surface finish, high dimensional and geometric precision. Because it is this kind of manufacture process, the parts machined by this have a high added value, since they have already undergone other machining processes and/or heat treatments and tempering. A limiting factor of grinding process is the amount of heat generated during it; which energy is minimized by application of cutting fluids. But these fluids, in most cases are pollutants and could contain substances that are harmful to health, in addition to having a high cost of purchase, maintenance and disposal. In order to reduce the amount of fluid used during the grinding process, the present research has been proposed with the aim of improving the technique of minimum quantity of lubrication by the combined application with compressed air at low temperature in order to improve the cooling effect ant thus minimize the heat in cutting zone. To evaluate the effectiveness of this technique, the finishing variables such as roughness and roundness, and process efficiency, such as grinding wheel wear and power consumed during machining, were chosen. These values were measured for three different methods of cutting fluids application during the grinding process, in order to compare them, the proposed method, CAMQL (cold air minimum quantity of lubrication) as compared to conventional fluid application (flood) and the minimum quantity lubrication with air in room temperature. For all parameters, the proposed cutting fluid reduction reached, in general, positives results, proving its... (Complete abstract electronica acess below) / Mestre
2

O Impacto da Janela no Conforto Térmico: Edificações Multifamiliares Ventiladas Naturalmente

Santo, Amabeli Dell 23 January 2014 (has links)
Made available in DSpace on 2016-08-29T15:10:14Z (GMT). No. of bitstreams: 1 tese_7447_Amábelli Dell Santo.pdf: 15621899 bytes, checksum: 4e01deecba0533012b07e586a27fa2b1 (MD5) Previous issue date: 2014-01-23 / CAPES / A edificação atua como mecanismo de controle das variáveis do clima, através de sua envoltória (paredes, cobertura e aberturas) e deve ser projetada de modo a proporcionar conforto e eficiência energética. Entre os componentes da envoltória, em edificações de múltiplos andares, as janelas merecem especial atenção devido à carga térmica recebida pela mesma. Os vidros das janelas funcionam, particularmente, como um dos elementos de maior potencialidade de aquecimento interno para climas tropicais, devido principalmente à sua transparência à radiação solar, possibilitando facilmente o ingresso de grande parte dessa energia que se converte em carga térmica. Nesta pesquisa foi analisado o desempenho térmico de ambiente de longa permanência (dormitório) em edifícios residenciais multifamiliares ventilados naturalmente, para a cidade de Vitória, considerando-se o comparativo entre dois modelos de janelas. A metodologia envolveu: 1) revisão bibliográfica visando o aprimoramento dos conceitos fundamentais de conforto térmico; estabelecimento de critérios para definição dos modelos de janela selecionados para estudo comparativo; e identificação de normas e metodologias de análise de conforto e desempenho térmico. 2) teste da metodologia que investigou o procedimento de análise mais adequado, através do software de simulação DesignBuilder. As análises buscaram especialmente o confronto com os critérios para avaliação de desempenho térmico propostos pela ABNT NBR 15575 utilizando a simulação computacional e referenciais de conforto do usuário considerandose o modelo de conforto adaptativo da ASHRAE. 3) ajuste final do procedimento para o estudo comparativo entre modelos de janelas. 4) avaliação dos resultados. Os resultados indicam, em média, uma redução de 45% da Frequência de Desconforto Térmico e redução de até 70% da Intensidade de Desconforto Térmico, para o ambiente analisado quando utilizado o modelo de janela com venezianas ao invés do modelo que não possui venezianas. Comprova-se assim, a eficiência do uso de venezianas como estratégia de condicionamento térmico passivo em dormitórios para a condição climática de Vitória, ES. / The building acts as a mechanism of control of climate variables, through its envelope (walls, roof and vents) and should be designed so as to provide comfort and energy efficiency. Among the components of the envelope, in multistory buildings, the windows deserve special attention due to thermal load they receive. The window panes work, particularly, as one of the elements of greater internal heating capability for tropical climates, mainly due to its transparency to direct solar radiation, easily allowing the inflow of much of this energy, which turns into thermal load. In this research it was analyzed the thermal performance of long permanence environment (dormitory) in free-running multifamily residential buildings, for Vitória city, considering the comparison between two models of windows. The methodology involved: 1) literature review aiming at the improvement of the fundamental concepts of thermal comfort; establishment of criteria for definition of models of window selected for comparative study; and identification of standards and methodologies of analysis of thermal comfort and performance. 2) testing of the methodology that investigated the most appropriate analysis procedure through the DesignBuilder simulation software. The analyses specially aimed the confrontation with the criteria for assessing thermal performance proposed by ABNT NBR 15575 using computater simulation and user comfort benchmarks considering the model of adaptive comfort of the ASHRAE. 3) final adjustment of the procedure for the comparative study between models of windows. 4) evaluation of the outcomes. The results indicate that, on average, a reduction of 45% in the frequency of thermal discomfort and reduction of up to 70% of the intensity of thermal discomfort, for the environment evaluated when the model of window was used with shutters instead of the model with no shutters. Thus, it is proved the efficiency of using blinds as a strategy of passive thermal conditioning in bedrooms for the climate condition of Vitória, ES.
3

Modelos numéricos para análise de elementos estruturais mistos.

Muniz, Cereno de Freitas Diniz Gonçalves January 2005 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-02-12T16:46:57Z No. of bitstreams: 1 DISSERTAÇÃO_ModelosNuméricosAnálise.pdf: 3741819 bytes, checksum: 04f4d41b1a4d3e7c9b301b7ba497b43d (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-02-12T18:14:37Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_ModelosNuméricosAnálise.pdf: 3741819 bytes, checksum: 04f4d41b1a4d3e7c9b301b7ba497b43d (MD5) / Made available in DSpace on 2016-05-04T14:34:33Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_ModelosNuméricosAnálise.pdf: 3741819 bytes, checksum: 04f4d41b1a4d3e7c9b301b7ba497b43d (MD5) Previous issue date: 2005 / Os elementos estruturais mistos, formados pela associação de perfis metálicos com o concreto, vêm se tornando uma solução atraente em diversos países, não só pelo aumento da capacidade de carga das peças estruturais, mas também devido a aspectos como economia e rapidez de execução da obra. Esta associação revela novos fenômenos que estão diretamente ligados à ação conjunta dos materiais e que, normalmente, são tratados de forma simplificada pelas normas. Este trabalho apresenta formulações numéricas para análise de elementos mistos utilizando elementos finitos de barra, que levam em consideração as não linearidades física e geométrica. A implementação realizada permite a consideração de qualquer tipo de seção transversal, que possa ser escrita em forma de poligonais, e de qualquer tipo de material, que possa ter sua relação constitutiva descrita através de funções polinomiais, abrangendo a grande maioria das situações encontradas na construção mista. Os elementos implementados permitem ainda a consideração de imperfeições geométricas iniciais e também análises no campo de grandes deslocamentos e grandes rotações através da utilização de elementos co-rotacionais. Um procedimento numérico de formulação simples, como no caso de elementos de barra, pode ser uma ferramenta de grande valor para pesquisadores e projetistas de estruturas mistas. O foco principal da dissertação é o comportamento de pilares mistos, mas, devido ao caráter genérico da formulação é possível o tratamento de elementos puramente metálicos ou de concreto armado. Ao longo do trabalho são descritas as principais particularidades inerentes a este tipo de estrutura e são apresentados os principais métodos de análise disponíveis na literatura. Resultados numéricos e experimentais são utilizados em comparações para verificação e validação do modelo proposto. Também são descritas, e comparadas através de exemplos, as prescrições do Eurocode 4 (1994), AISC-LRFD (1999, 2005) e do projeto de revisão da NBR 8800 (2003). ______________________________________________________________________________________ / ABSTRACT: Steel-Concrete composite members, formed by the association of steel profiles with concrete, are an attractive structural solution in many countries, not only by the increase on the load carrying capacity but also due to aspects related with cost saving and speed of construction. This association gives rise to new phenomena related with the combined action of the materials and generally treated by the design codes in a simplified way. This work presents numerical formulations for the analysis of composite members using beam-column finite elements using physical and geometrical nonlinearity assumptions. The developed implementation allows the consideration of a generic cross section, as long as it can be represented by polygons, and any type of material with piecewise polynomial stress-strain relation. This encompasses most practical situations usually found in composite construction. The implemented elements allows the consideration of initial lack of straightness of the element axis and also large displacements and large rigid-body rotations through the use of co-rotational technique. A simple numerical procedure, as is the case of bar elements, can be a useful tool for researchers and designers of composite structures. The main objective of this dissertation is the study of composite columns. Nonetheless, the generic aspect of the implemented formulation allows the treatment of bare steel elements and reinforced concrete members as well. The proposed numerical model is compared to other numerical and experimental results. The inherent characteristics of these structural elements are described and the most important methods of analysis available in literature are presented. Finally, the design methods recommended in Eurocode 4 (1994), AISC-LRFD (1999, 2005) and NBR 8800 (Draft-2003) are presented and evaluated through numerical examples.
4

Avaliação do nível de maturidade do sistema de gestão da qualidade para pequenas e médias empresas: proposição de um modelo

RUFINO, Jessika da Silva 15 December 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2018-02-08T19:05:59Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jéssika Rufino Dissertação.pdf: 2280569 bytes, checksum: 33d54b70234925f3e089e337e7de9dd3 (MD5) / Made available in DSpace on 2018-02-08T19:05:59Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jéssika Rufino Dissertação.pdf: 2280569 bytes, checksum: 33d54b70234925f3e089e337e7de9dd3 (MD5) Previous issue date: 2016-12-15 / CAPES / A avaliação do nível de maturidade busca investigar quais os pontos fortes e fracos de cada organização nos aspectos de qualidade e assim facilitar a implantação, manutenção e melhoria de um Sistema de Gestão da Qualidade (SGQ). O referido trabalho tem por objetivo a elaboração de um modelo para avaliação do nível de maturidade organizacional em relação à Gestão da Qualidade (estruturado, de embasamento técnico – científico, de fácil aplicabilidade e voltado a pequenas e médias empresas), tomando como base as ferramentas de autoavaliação disponíveis nas ISO 9004 e 10014 (normas ISO de apoio) assim como os modelos de maturidade existentes na literatura. Com isso, a ferramenta final torna-se de aplicabilidade fácil, com um grande potencial de atendimento as necessidades destas organizações. A aplicação do modelo em duas empresas, de médio e pequeno porte, mostrou resultados satisfatórios na descrição da maturidade, e em todos os sete elementos avaliados percebeu-se nos resultados obtidos grande correspondência com a realidade observada, de modo que pôde-se diagnosticar os pontos fortes e fracos destas organizações, e com o auxílio das diretrizes de melhoria, auxiliá-los nos caminhos à serem seguidos para um melhor desenvolvimento. / The maturity level evaluation seeks to investigate the strengths and weaknesses of each quality quality organization and to assimilate the implementation, maintenance and improvement of a Quality Management System (QMS). The project aims at the elaboration of a model for the evaluation of the level of organizational maturity in relation to Quality Management (structured, based on technical and scientific, easy application and aimed at small and medium enterprises), based on tools Self-assessment applicable to ISO 9004 and ISO 10014 (ISO support standards) as well as existing maturity models in the literature. With this, a final tool becomes of easy application, with a great potential of attendance as the needs of the organizations. The application of the model in two companies, medium and small, showed satisfactory results in the description of maturity, and in all seven elements obtained perceived results obtained large correspondence with an observed reality, so that could be diagnoses Strengths And weak organizations, and with the help of improvement guidelines, and the paths to better results.
5

Avaliação do nível de maturidade do sistema de gestão da qualidade para pequenas e médias empresas : proposição de um modelo

RUFINO, Jessika da Silva 16 December 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2018-02-15T19:54:56Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jéssika Rufino Dissertação.pdf: 2280569 bytes, checksum: 33d54b70234925f3e089e337e7de9dd3 (MD5) / Made available in DSpace on 2018-02-15T19:54:56Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jéssika Rufino Dissertação.pdf: 2280569 bytes, checksum: 33d54b70234925f3e089e337e7de9dd3 (MD5) Previous issue date: 2016-12-16 / CAPES / A avaliação do nível de maturidade busca investigar quais os pontos fortes e fracos de cada organização nos aspectos de qualidade e assim facilitar a implantação, manutenção e melhoria de um Sistema de Gestão da Qualidade (SGQ). O referido trabalho tem por objetivo a elaboração de um modelo para avaliação do nível de maturidade organizacional em relação à Gestão da Qualidade (estruturado, de embasamento técnico – científico, de fácil aplicabilidade e voltado a pequenas e médias empresas), tomando como base as ferramentas de autoavaliação disponíveis nas ISO 9004 e 10014 (normas ISO de apoio) assim como os modelos de maturidade existentes na literatura. Com isso, a ferramenta final torna-se de aplicabilidade fácil, com um grande potencial de atendimento as necessidades destas organizações. A aplicação do modelo em duas empresas, de médio e pequeno porte, mostrou resultados satisfatórios na descrição da maturidade, e em todos os sete elementos avaliados percebeu-se nos resultados obtidos grande correspondência com a realidade observada, de modo que pôde-se diagnosticar os pontos fortes e fracos destas organizações, e com o auxílio das diretrizes de melhoria, auxiliá-los nos caminhos à serem seguidos para um melhor desenvolvimento. / The maturity level evaluation seeks to investigate the strengths and weaknesses of each quality quality organization and to assimilate the implementation, maintenance and improvement of a Quality Management System (QMS). The project aims at the elaboration of a model for the evaluation of the level of organizational maturity in relation to Quality Management (structured, based on technical and scientific, easy application and aimed at small and medium enterprises), based on tools Self-assessment applicable to ISO 9004 and ISO 10014 (ISO support standards) as well as existing maturity models in the literature. With this, a final tool becomes of easy application, with a great potential of attendance as the needs of the organizations. The application of the model in two companies, medium and small, showed satisfactory results in the description of maturity, and in all seven elements obtained perceived results obtained large correspondence with an observed reality, so that could be diagnoses Strengths And weak organizations, and with the help of improvement guidelines, and the paths to better results.
6

Utilização do método Analytic Hierarchy Process (AHP) para localização de usina de reciclagem de resíduos da construção civil

Silva, Mayara Cristina Ghedini da 07 May 2012 (has links)
CAPES / Este trabalho teve por objetivo propor uma metodologia para identificação de potenciais locais para a implantação de uma usina de reciclagem de Resíduos da Construção Civil (RCC), na cidade de Ponta Grossa. Para isto, foi desenvolvida uma contextualização sobre: sustentabilidade e desenvolvimento sustentável; Resolução do CONAMA; Norma da ABNT e legislação municipal, que impõem critérios para a implantação de usina para a reciclagem dos mesmos. Buscando responder os objetivos específicos deste trabalho, a metodologia aplicada foi dividida em cinco etapas, sendo elas: levantamentos bibliográficos e documentais, para seleção de critérios e subcritérios; validação dos critérios; definição das alternativas; desenvolvimento da estrutura hierárquica e aplicação do modelo no software Expert Choice 11.5. Com este trabalho, foi desenvolvida uma metodologia aplicável em diferentes cidades, que tenham como objetivo a implantação de uma usina de reciclagem. O método Analytic Hierarchy Process (AHP) possibilitou transformar informações qualitativas em quantitativas, facilitando assim os processos decisórios. Deste modo, concluiu-se que com a aplicação do método AHP que o critério Pilar Ambiental apresenta-se como maior fator de tomada de decisão, e o terreno localizado no bairro de Uvaranas, apresenta-se como a alternativa com maior potencial para a implantação da usina de reciclagem de RCC, na cidade de Ponta Grossa. / This research aimed to propose a methodology for identifying potential sites to locate a waste recycling plant of Civil Construction in Ponta Grossa city. For this, presenting a background on: sustainability and sustainable development; CONAMA Resolution; ABNT rules and municipal laws, which impose criteria for the establishment of the plant for recycling them. Seeking to answer the specific objectives of this study, the methodology applied was divided into five stages, namely: bibliographic and documentary, to select criteria and sub criteria; criteria validation, definition of alternatives; development of the hierarchical structure and application of the model in software Expert Choice 11.5. With this work, it was developed a applicable methodology in different cities, which have as their objective the establishment of a recycling plant. The Analytic Hierarchy Process (AHP) method allowed to transform qualitative informations into quantitative, so facilitating decision making processes. Can be concluded that with the application of AHP method which the criterion Environmental Pillar presents itself as a major factor in decision making and the land located in the Uvaranas neighborhood, presents itself as the alternative with the greatest potential to locate a waste recycling plant of Civil Construction in Ponta Grossa city.
7

Análise comparativa entre métodos de cargas térmica e de eficiência energética em edificações / Rafael Ângelo Gentilini ; orientador, Nathan Mendes ; co-orientadora, Kátia C. Mendonça

Gentilini, Rafael Ângelo January 2012 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Bibliografia: f. 104-108 / O presente estudo tem como objetivo contribuir para o aprimoramento do processo de etiquetagem de edificações comerciais, sobretudo da parcela referente aos sistemas de condicionamento de ar. Haja vista que, para o cálculo da carga térmica de instalações / The aim of this study is to be a contribution to the improvement of labeling process of commercial buildings, especially processes related to air conditioning systems; considering that to calculate heat load of small facilities, the ABNT NBR 16401:2008 st
8

Análise da vida útil estimada das edificações baseada na norma de desempenho (ABNT NBR 15.575:2013)

Nina Celeste Macario Simões da Silva 25 February 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A análise da vida útil (VU) de uma edificação exige a observação de muitas variáveis, especialmente aquelas voltadas para o desempenho e durabilidade. Nesse sentido, a ABNT NBR 15.575:2013 Edificações habitacionais Desempenho estabelece requisitos, critérios e métodos de avaliação para analisar o desempenho das construções, e ao mesmo tempo subsidiar os projetistas a determinar a vida útil de projeto (VUP) condizente com o nível de desempenho desejado pelo construtor e usuário. Acrescente-se que o cálculo para a vida útil estimada (VUE) das construções leva em consideração o envelhecimento natural dos componentes dos sistemas construtivos, mas não contempla o efeito dos danos provocados pela entrada em operação e uso da edificação ou ausência de manutenção. Além disso, a ABNT NBR 5674:2012 - Manutenção de edificações Requisitos para o sistema de gestão de manutenção, indica quais os sistemas e serviços devem passar pelo processo de manutenção e em qual período, possibilitando a gestão da manutenção com qualidade. Entretanto, não é sempre o que ocorre nas edificações após a entrada em operação e uso. Na pesquisa, procurou-se, então, verificar qual a relação entre a vida útil estimada e os prazos de garantia das obras. Para medir a diferença percentual entre a VUP e a VUE, após a intervenção da ATPO foi utilizado o método dos fatores previsto na ISO 15.686:2000 - Building and construction assets service life planning e recomendado pela NBR 15.575-1:2013. As informações analisadas foram cedidas por uma construtora atuante na cidade do Recife, coletadas de um banco de dados proveniente da assistência técnica pós-obra (ATPO) de oito empreendimentos construídos na Região Metropolitana do Recife. A frequência de ocorrência de danos nas edificações foi analisada através da determinação da taxa de falhas dos empreendimentos. Os resultados assinalam para um percentual de redução da vida útil de projeto (VUP), da ordem de 20% da vida útil de referência (VUR), valores adotados da NBR 15.575:2013; apontam também, para uma concentração de avarias no estágio inicial da construção, acima de 50%, que correlacionando com a curva de probabilidade condicional de falha (curva da banheira) obtém-se um alto índice de falha brusca, classificando a edificação na fase da mortalidade infantil. Esses resultados refletem uma variação não planejada do nível de desempenho proposto para a edificação. Diante desse contexto, sugere-se vincular o prazo de garantia da obra com o nível de desempenho efetivo da construção. A aplicação de conceitos de confiabilidade permite inferir sobre os prazos de garantia da obra e fazer comparações com o valor previsto no aparato legal brasileiro. / Analysis of service life of a building requires the observation of many variables, especially corre-lating to the performance and durability. In this meaning, the NBR 15.575:2013 - Residential Buildings - Performance establishes requirements, criteria and methods assessment for analyz-ing the performance of buildings, and sometimes subsidize designers to determine the design life consistent with the performance level desired by the builder and user. Adding that the calculation of the estimated service life of buildings takes into account the natural aging of the building sys-tems components, but not contemplates of the damage effect caused by the entry into operation and use of the building or absence conservation. Moreover, the NBR 5.674:2012 - Buildings Maintenance - Requirements for the maintenance management system, indicates which systems and services that must go through the maintenance process and in what period, enabling mainte-nance management quality. However, it is not always what happens in the buildings after entry into operation and use. In the survey, we tired so verify the relationship between the predicted service life and the warranty period of the building. The information analyzed were provided by an active construction of Recife, collected in a database from the technical assistance after work eight buildings in the Metropolitan Region of Recife. To measure the percentage difference be-tween the design life and estimated service life, following the intervention of the technical assis-tance after work was used the factors method set out in ISO 15.686:2000 - Building and construc-tion assets - Service life planning and recommended by NBR 15575-1:2013. The frequency of occurrence damage in buildings was analyzed by determining the rates of failure in the buildings. The results show to a reduction of the design life of the order of 20% of the reference service life, from values adopted in the Performance of Brazilian Standard; also point to a concentration of damage in the initial stage of construction, above 50%, which correlate with the conditional prob-ability of failure curve (Bathtub Curve) sorting a high abrupt failure rate, ranking the building at the stage of infant mortality. These results reflect an unplanned variation in performance level proposed for the building. In this context, it is suggested to link the period of the works guarantee to the level of actual performance of the building. The application of reliability concepts allows infer about warranty period of the Building and make comparisons with the requirement of Brazi-lian law enforcement.
9

Caracterização de impacto ambiental no solo em um aterro de pequeno porte /

Bellezoni, Rodrigo Augusto. January 2012 (has links)
Orientador: Jorge Hamada / Banca: Ana Silvia Palcheco Peixoto / Banca: Vagner Roberto Elis / Resumo: A disposição de resíduos sólidos no solo gera frequentes preocupações ambientais, sociais e de saúde pública. Os aterros sanitários de pequeno porte são uma alternativa sugerida por órgãos ambientais no Estado de SP para que pequenos municípios possam destinar seus resíduos de forma ambientalmente segura, a custos reduzidos. Esta pesquisa teve como objetivo avaliar, sob a análise de aspectos físicos e geofísicos, se este mecanismo possui capacidade em conter os líquidos percolados das colunas de resíduos, evitando riscos de contaminação no solo e águas subterrâneas. Para tanto, características físicas da área de influência do aterro foram determinadas com auxílio de mapas, assim como as características físicas foram determinadas através de ensaios padrão. O método da Eletrorresistividade foi empregado para caracterizar o solo em subsuperfície e estimar sua capacidade na atenuação de contaminantes. Os resultados mostraram o potencial de aplicação deste método, através da relação entre elevada carga iônica e baixa resistividade elétrica, definindo com clareza o limite das plumas de contaminantes. O chorume ocorre em grande parte das valas mais recentes, devido à etapa de decomposição. Valas antigas apresentaram tendência de aumento na resistividade, significando queda na geração de chorume, concomitante ao aumento do tempo de resistividade dos resíduos. Assim, a zona de influência dos resíduos limitou-se à 20 m da área de disposição no plano horizontal e até 8,5 em profundidade. As propriedades físico-químicas do solo argiloso local influenciaram o comportamento da pluma de contaminantes, visto a redução destas ao longo do tempo. Destacam-se o mineral de argila e a granulometria como os possíveis principais responsáveis pela atenuação natural dos contaminantes. Em alguns... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The disposal of solid waste in the soil often creates environmental, social and public health concerns. Small landfills are an alternative suggestion by environmental agencies in the State of São Paulo so small cities direct their waste in an environmentally safe manner, at costs. This research is aimed to evaluate, under the analysis of physical and geophysical concepts, if this mechanism has the capacity to contain lanchated liquid from the columns of waste, avoiding risks of contamination in soil and groundwater. Thus, physical characteristics of landfill catchment area were determined with the aid of maps, as well as the physical characteristics of the local soil were determined by standard assays. The Electrical Resistivity method was employed to characterize the subsoil and to estimate its ability to attenuate contaminants. The results showed the potential application of this method through the relationship between hhigh ionic charge and low resistivity, defining clearly the limits of contaminant plumes. Leachate occurs largely in the more recent dithes, due to the decomposition phase. Older ditches tended to increase in resistivity; it means decrease of leachate generation, as well the increase of waste time residence. Thus, the waste influence zone was limited to 10 m of the disposal area in the horizontal plane and up to 8.5 m in depth. The physicochemical properties of the clay soil spot have influenced the contaminants plume behavior, to reduce it along the time. Emphasizing this are the clay mineral and grain size held as possible primary accountable for natural attenuation of contaminants. At some ponts, it is estimated that the layer of unsaturated soil under the ditches be less that one meter, it does not comply the criteria for exemption of additional waterproofing, established in NBR 15.849:2010 Municipal solid waste... (Complete abstract click electronic access below)
10

Desempenho acústico das edificações segundo a NBR 15575 (ABNT, 2013): desempenho das vedações e validação dos requisitos normativos com base na opinião dos usuários / Acoustic Performance of buildings according to NBR 15575 (ABNT, 2013): performance of seals and validation of regulatory requirements-based user view

SANTANA, Wylliam Bessa 18 March 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:32:22Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoAcusticoEdificacoes.pdf: 3956994 bytes, checksum: 8aac33ee018f87ebe777d0790db69806 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-22T12:29:37Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoAcusticoEdificacoes.pdf: 3956994 bytes, checksum: 8aac33ee018f87ebe777d0790db69806 (MD5) / Made available in DSpace on 2017-03-22T12:29:37Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoAcusticoEdificacoes.pdf: 3956994 bytes, checksum: 8aac33ee018f87ebe777d0790db69806 (MD5) Previous issue date: 2016-03-18 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Com o crescimento dos grandes centros urbanos no Brasil, a concentração populacional e a necessidade de moradia levaram à grande procura por residências geminadas e edifícios habitacionais com inúmeros apartamentos, que, no entanto, com o passar do tempo tornaram-se fruto de reclamações dos usuários em consequência do baixo desempenho das vedações. Era necessário a normalização do desempenho das edificações. Diversas normas internacionais abordam o tema, entretanto apenas em 2013 foi publicada a norma brasileira de desempenho das edificações NBR 15575 (ABNT, 2013), estipulando dentre outros aspectos, requisitos para o desempenho acústico ao ruído aéreo de lajes e paredes, internas e externas, e para o desempenho acústico ao ruído de impacto de lajes. No entanto, surgem algumas perguntas, como: as tipologias construtivas atuais atendem a estes critérios de desempenho acústico? Ou, será que estes critérios são adequados? Foi com o objetivo de responder a estas perguntas, especificamente, que este trabalho foi realizado. Para isso, foram executados ensaios em campo e aplicados questionários com os moradores. Os resultados demonstram que dentre as vedações cujo desempenho acústico é exigido, as paredes internas se mostram mais distantes de atender a estes critérios, e as externas atendem com dificuldade, inclusive segundo a percepção dos usuários. Quanto aos requisitos normativos para o desempenho acústico, são expressivos os níveis de incômodo gerados por cargas de impacto nas lajes, evidenciando o baixo rigor, e ainda mais preocupante que este último, é o fato de a norma ignorar o ruído de impacto propagado entre paredes, destacado pela imensa maioria dos entrevistados como a principal fonte de ruído. / With the growth of large urban centers in Brazil, the population density and the need for housing led to high demand for semi-detached homes and apartment houses with numerous apartments, however, with the passage of time they became the result of user complaints in consequence of the low performance of the buildings. The normalization of the performance of the buildings was necessary. Several international standards address the issue, but only in 2013 was published the Brazilian standard of buildings performance NBR 15575 (ABNT, 2013), stipulating among other things, requirements for acoustic performance of internal and external walls, and slabs about the noise impact and air. However, there are some questions, such as: does the current construction typology meet these performance acoustic criteria? Are these criteria suitable? Among to answer these questions, field tests and questionnaires were performed with residents. Among the seals whose acoustic performance is required, the results show the inner walls are more distant to meet these criteria, and the external meet with difficulty, even as perceived by users. About the regulatory requirements for acoustic performance, are significant the annoyed levels generated by impact loads on slabs, highlighting the low accuracy, and even more worrying that the latter is the fact in not require acoustic performance criteria regarding the impact noise between walls, highlighted by the vast majority of respondents as the main source of noise.

Page generated in 0.098 seconds