• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 2
  • Tagged with
  • 18
  • 14
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A study on the innervation of the equine hip and knee (stifle) joint capsules

Rankin, John January 1975 (has links)
No description available.
2

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Miyashita, Elcio Ricardo 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
3

Avaliação das tensões ósseas geradas por prótese obturadora maxilar implanto-retida pelo sistema ERA® por meio da análise de elementos finitos / Evaluation of bone stress with implant retained obturator prosthesis with ERA® system through finite element analysis

Costa, Valéria Tognato 10 May 2016 (has links)
Visando melhorar a qualidade de vida dos pacientes com perdas de estrutura maxilar faz-se necessária sua reabilitação, seja ela cirúrgica ou protética por meio de próteses obturadoras, esta última, um recurso terapêutico que minimiza os distúrbios funcionais, estéticos e psicológicos. Este estudo avaliou o comportamento biomecânico de prótese obturadora maxilar Classe II de Okay retida por implantes e sistema de retenção ERA®, observando as tensões geradas no tecido gengivo-mucoso e ósseo maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir da tomografia computadorizada de um indivíduo adulto. Quatro implantes foram posicionados na maxila, em região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, onde as estruturas do sistema de retenção ERA® foram posicionadas nas extremidades de uma barra metálica e convertidas para serem representadas por superfícies. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes, UCLAS e o CAD do sistema de retenção ERA®. O CAD do sistema ERA®, fundido em metal, foi desenvolvido a partir de imagens geradas pelo microCT SkyScan 1176 Bruke no formato BMP e TIFF. Essas imagens no formato TIFF foram exportadas para o software img2dcm, convertidas para o formato DICOM e então exportadas para o software Invesalius que reconstruiu tridimensionalmente gerando uma malha no formato STL. As estruturas finalizadas foram exportadas para software Hyperworks 13.0 e pós-processadas com a visualização de resultados pelo Hyperview, tendo sido aplicada uma força de 80N na plataforma oclusal e de 35N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de máxima tensão principal e os valores quantitativos expressos em MPa. Ocorreu um deslocamento máximo da prótese obturadora na região sem suporte ósseo, tendo como fulcro a linha de ressecção óssea. Observou-se menos forças de tração do que de compressão. As forças analisadas se mostraram bastante favoráveis à estabilidade da prótese obturadora implanto-retida por se apresentarem bem distribuídas pelo tecido gengivo-mucoso e ósseo da maxila remanescente, indicando que o sistema ERA® de retenção é adequado para reabilitação maxilar das perdas ósseas Classe II de Okay. / Searching to improve quality of life of the patients that had sustained structural maxillary loss with the necessity of rehabilitation, either through surgery or obturator prosthesis, which is a therapeutic resource to minimize functional, esthetic and psychological impairments. This study evaluated the biomechanical behavior of an Okay Class II obturator prosthesis implant retained and ERA® system, analyzing the resultant stress on the soft and bone tissue. The finite element analysis was made with a digital model constructed from a computed tomography. Four implants were positioned on the left maxillae, on the following regions: lateral incisor, canine, second premolar and first molar, with the ERA® system positioned on the extremities of a metallic bar. The software used to create the BioCAD 3D model was Rhinoceros v. 5.0, including the CAD models from the implants, UCLAS and ERA® system. The ERA® CAD model was obtained from a microCT SkyScan 1176 Bruke images, on the BMP and TIFF format. The TIFF images were exported to the img2dcm software, converted in DICOM format and finally exported to the software Invesalius, were the STL mesh was created. All mesh were imported into the software Hyperworks v. 13.0 and the post-processing was visualized on Hyperview. The force applied was of 80N over the occlusal platform and of 35N over the incisal platform. A quantitative analysis was performed, corresponding to the maximum main stress, expressed in MPa. The obturator prosthesis suffered its maximum dislocation on the region with no bone support, with the bone resection line as fulcrum. Less tension forces were observed, when comparing to compression. The forces observed were favorable to maintain the implant retained prosthesis stabilization, with good distribution over the soft and bone tissues, suggesting that the ERA® retention system is suitable to Okay Class II maxillary bone loss.
4

Análise das tensões geradas por prótese obturadora maxilar implanto-retida por meio da análise de elementos finitos / Avaliation of stresses generated by the maxillary obturator prosthesis implant-retained by the finite element analysis

Sousa, Andréa Alves de 07 August 2012 (has links)
Neste estudo avaliou-se o comportamento biomecânico de próteses obturadoras maxilares Classe Ib, II e III de Okay retidas por implantes, observando as tensões geradas no tecido ósseo e gengivo-mucoso maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo adulto. Utilizou-se o programa Rhinoceros® versão 4.0 SR9 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes e UCLAS. Os implantes foram posicionados de acordo com cada modelo: Modelo 1 (Classe Ib de Okay): 6 implantes posicionados em regiões de caninos e incisivos laterais bilateralmente e em região de segundo premolar e primeiro molar esquerdos onde foram utilizados 4 clipes para o sistema de retenção barra/clipe; Modelo 2 (Classe II de Okay): 4 implantes posicionados em região de canino, incisivo lateral, segundo premolar e primeiro molar esquerdos, com 3 clipes; Modelo 3 (Classe III de Okay): 2 implantes posicionados em região de segundo premolar e primeiro molar esquerdos, com 2 clipes. A malha de elementos finitos foi gerada pelo programa Ansys®, tendo sido aplicada uma força de 80 N na plataforma oclusal, e de 35 N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal, com valores quantitativos expressos em MPa. O deslocamento da prótese obturadora na região sem suporte ósseo aumentou em função da diminuição da área de suporte ósseo, do número de implantes e de clipes; a mucosa gengival, o osso cortical e o osso medular sofreram tensões de tração e de compressão que aumentaram em função da diminuição da área de suporte ósseo, do número de implantes e de clipes. Concluiu-se que quanto maior a perda da área de suporte ósseo em uma maxilectomia, maiores serão as forças de tensão e de compressão geradas pelo sistema de retenção barra/clipe nos tecidos remanescentes e maior será a tendência para o deslocamento da prótese. / Patients submitted to maxillectomy due to oral cancer shall be rehabilitated by means of obturator prosthesis in order to achieve a better quality of life. This study evaluated the biomechanics of implant-retained obturator prostheses analyzing the stress on maxillary osseous and gingivo-mucosal tissues. Finite elements analysis was developed using a 3D digital model based on a computed tomography of an adult man. Files were processed by Software Rhinoceros®, v4.0 SR9 and generated a maxillary BioCAD 3D model, which incorporated the CAD models of the implants and UCLAS. The implants were located considering: Model 1 (Okay Class Ib) - 6 implants in the areas of canines and lateral incisors and in the areas of left second premolar and molar, retention system bar/4 clips; Model 2 (Okay Class II ) - 4 implants located in the areas of canine, lateral incisor, left second premolar and first molar, retention system bar/3 clips; Model 3 (Okay Classe III) - 2 implants inserted in the left second premolar and first molar, retention system bar/2clips. The finite elements mesh was generate using Software Ansys®. A force of 80 N was applied to the occlusal platform and, at the same time, a force of 35 N was applied to the incisal platform of the obturator prosthesis. Results considered a qualitative analysis, based on the scale of maximum principal stress, and a quantitative analysis, when values were expressed in MPa. The dislodgement of the obturator prosthesis in the area with no osseous support increases as the area of the osseous support, the number of implants and clips diminish; the tensile and compressive stress in the gingival mucosa, the cortical and the alveolar bone increase as the osseous support, the number of implants and of clips diminish. The larger the area without osseous support, the higher the tensile and compressive stress in the remaining tissues and greater the displacement of the prosthesis.
5

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Elcio Ricardo Miyashita 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
6

Silicone obturators and the bacterial flora in symptomatic nasal septal perforations

Hulterström, Anna Karin January 2012 (has links)
Background A perforation in the nasal septum can cause symptoms such as bleeding, obstruction, crusts and pain, and can be a challenge to treat. Surgery is the treatment of choice, but disease, size of the perforation, or the patient’s wish may contradict surgery. A custom-made silicone obturator is a successful treatment option, but little is known how this treatment affects the microbial flora. The purposes of this thesis were (i) to investigate the microbial flora around symptomatic nasal septal perforations before treatment, (ii) during and after a 12-month treatment period with a custom-made obturator, (iii) to compare the microbial flora around symptomatic perforations with the flora from the same area of the septum in healthy individuals, (iv) to investigate the microbial colonization of the silicone obturator, and (v) also to investigate the water sorption, solubility and if the wettability of silicones are affected by water. The hypotheses were (i) that the bacterial flora around symptomatic perforations would not differ from that found in healthy individuals, apart from a possible presence of Helicobacter pylori; (ii) the bacterial flora would change in composition during the course of treatment and that microorganisms and proteins could be seen on the surface of the silicone obturators; (iii) a material that has adsorbed water would also show an increase in wettability and the surface free energy of the material.  Methods Twenty-seven patients and 101 healthy individuals volunteered. Swabs were made around the rim of the perforation, or on the septum in the locus Kisselbachi area in the healthy individuals. Bacteria and fungi were isolated and identified with standard laboratory techniques. A biopsy of the granulated tissue at the perforation was taken and cultivated for Helicobacter pylori. Swabs were also taken three, six and twelve months after inserting the obturator. The obturator was analysed after being used twelve months in the nose.  Seven silicones were tested for water sorption and solubility according to ISO standards 1567:1999 and ISO 10477:2004. The change in wettability was examined by measuring the contact angle with a contact goniometer at various stages of the sorption/solubility test. Results Staphylococcus aureus was present in 88% of the untreated patients. With treatment a significant reduction of S. aureus occurred to 54.5% (p<0.05). In the healthy group S. aureus was present in 13% of the subjects. No Helicobacter pylori could be cultivated from the biopsies taken of the granulated tissue at the perforation. The flora round the untreated perforation was dominated by S. aureus with few other bacterial species detected. In the healthy group there was a diversified flora with both aerobic and anaerobic bacteria. SEM revealed a rough surface on the silicone obturator and crazing of the silicone surrounding the pigment granules. Both bacteria and proteins could be seen on the obturators in SEM. Candida albicans was detected in one obturator, but not in the mucosal swab at the corresponding time. That patient had, however, been treated for Candida in the nose six months prior to the last visit in the study. Wettability was affected but did not increase with amount of adsorbed water. Some materials showed an increase and some a decrease in the surface-free energy. The tested addition silicones showed little sorption and solubility. Conclusions The patients with symptomatic perforations of the nasal septum had a bacterial flora totally dominated by S. aureus. The massive presence of S. aureus around symptomatic perforations may have an impact on the persistence of the granulated and inflamed tissue present in symptomatic perforations, thus forming a vicious circle with bleeding and crustation. S. aureus dominance in the mucosa surrounding symptomatic perforations was diminished by using a custom-made obturator. The microbial flora became more diversified with the treatment, although not resembling the flora in healthy individuals. The microbial flora of the obturators was similar, but not the same as the corresponding mucosal flora. The discovery of Candida in the obturator of a patient who had been treated for Candida in the nose six months earlier suggests that obturators need to be exchanged when fungal infections are being treated to prevent the fungus from re-infecting the patient at a later stage. The silicone had a rough surface and a poor wettability, both aspects favours colonization of microorganisms. The silicone was negatively affected by the colouring pigments, this should be considered when colouring is not necessary. The slight, but existing solubility of silicones emphasises the importance of using medical grade silicones that are more purified than industrial silicones.
7

Análise das tensões geradas por prótese obturadora maxilar implanto-retida por meio da análise de elementos finitos / Avaliation of stresses generated by the maxillary obturator prosthesis implant-retained by the finite element analysis

Andréa Alves de Sousa 07 August 2012 (has links)
Neste estudo avaliou-se o comportamento biomecânico de próteses obturadoras maxilares Classe Ib, II e III de Okay retidas por implantes, observando as tensões geradas no tecido ósseo e gengivo-mucoso maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo adulto. Utilizou-se o programa Rhinoceros® versão 4.0 SR9 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes e UCLAS. Os implantes foram posicionados de acordo com cada modelo: Modelo 1 (Classe Ib de Okay): 6 implantes posicionados em regiões de caninos e incisivos laterais bilateralmente e em região de segundo premolar e primeiro molar esquerdos onde foram utilizados 4 clipes para o sistema de retenção barra/clipe; Modelo 2 (Classe II de Okay): 4 implantes posicionados em região de canino, incisivo lateral, segundo premolar e primeiro molar esquerdos, com 3 clipes; Modelo 3 (Classe III de Okay): 2 implantes posicionados em região de segundo premolar e primeiro molar esquerdos, com 2 clipes. A malha de elementos finitos foi gerada pelo programa Ansys®, tendo sido aplicada uma força de 80 N na plataforma oclusal, e de 35 N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal, com valores quantitativos expressos em MPa. O deslocamento da prótese obturadora na região sem suporte ósseo aumentou em função da diminuição da área de suporte ósseo, do número de implantes e de clipes; a mucosa gengival, o osso cortical e o osso medular sofreram tensões de tração e de compressão que aumentaram em função da diminuição da área de suporte ósseo, do número de implantes e de clipes. Concluiu-se que quanto maior a perda da área de suporte ósseo em uma maxilectomia, maiores serão as forças de tensão e de compressão geradas pelo sistema de retenção barra/clipe nos tecidos remanescentes e maior será a tendência para o deslocamento da prótese. / Patients submitted to maxillectomy due to oral cancer shall be rehabilitated by means of obturator prosthesis in order to achieve a better quality of life. This study evaluated the biomechanics of implant-retained obturator prostheses analyzing the stress on maxillary osseous and gingivo-mucosal tissues. Finite elements analysis was developed using a 3D digital model based on a computed tomography of an adult man. Files were processed by Software Rhinoceros®, v4.0 SR9 and generated a maxillary BioCAD 3D model, which incorporated the CAD models of the implants and UCLAS. The implants were located considering: Model 1 (Okay Class Ib) - 6 implants in the areas of canines and lateral incisors and in the areas of left second premolar and molar, retention system bar/4 clips; Model 2 (Okay Class II ) - 4 implants located in the areas of canine, lateral incisor, left second premolar and first molar, retention system bar/3 clips; Model 3 (Okay Classe III) - 2 implants inserted in the left second premolar and first molar, retention system bar/2clips. The finite elements mesh was generate using Software Ansys®. A force of 80 N was applied to the occlusal platform and, at the same time, a force of 35 N was applied to the incisal platform of the obturator prosthesis. Results considered a qualitative analysis, based on the scale of maximum principal stress, and a quantitative analysis, when values were expressed in MPa. The dislodgement of the obturator prosthesis in the area with no osseous support increases as the area of the osseous support, the number of implants and clips diminish; the tensile and compressive stress in the gingival mucosa, the cortical and the alveolar bone increase as the osseous support, the number of implants and of clips diminish. The larger the area without osseous support, the higher the tensile and compressive stress in the remaining tissues and greater the displacement of the prosthesis.
8

Avaliação das tensões ósseas geradas por prótese obturadora maxilar implanto-retida pelo sistema ERA® por meio da análise de elementos finitos / Evaluation of bone stress with implant retained obturator prosthesis with ERA® system through finite element analysis

Valéria Tognato Costa 10 May 2016 (has links)
Visando melhorar a qualidade de vida dos pacientes com perdas de estrutura maxilar faz-se necessária sua reabilitação, seja ela cirúrgica ou protética por meio de próteses obturadoras, esta última, um recurso terapêutico que minimiza os distúrbios funcionais, estéticos e psicológicos. Este estudo avaliou o comportamento biomecânico de prótese obturadora maxilar Classe II de Okay retida por implantes e sistema de retenção ERA®, observando as tensões geradas no tecido gengivo-mucoso e ósseo maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir da tomografia computadorizada de um indivíduo adulto. Quatro implantes foram posicionados na maxila, em região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, onde as estruturas do sistema de retenção ERA® foram posicionadas nas extremidades de uma barra metálica e convertidas para serem representadas por superfícies. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes, UCLAS e o CAD do sistema de retenção ERA®. O CAD do sistema ERA®, fundido em metal, foi desenvolvido a partir de imagens geradas pelo microCT SkyScan 1176 Bruke no formato BMP e TIFF. Essas imagens no formato TIFF foram exportadas para o software img2dcm, convertidas para o formato DICOM e então exportadas para o software Invesalius que reconstruiu tridimensionalmente gerando uma malha no formato STL. As estruturas finalizadas foram exportadas para software Hyperworks 13.0 e pós-processadas com a visualização de resultados pelo Hyperview, tendo sido aplicada uma força de 80N na plataforma oclusal e de 35N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de máxima tensão principal e os valores quantitativos expressos em MPa. Ocorreu um deslocamento máximo da prótese obturadora na região sem suporte ósseo, tendo como fulcro a linha de ressecção óssea. Observou-se menos forças de tração do que de compressão. As forças analisadas se mostraram bastante favoráveis à estabilidade da prótese obturadora implanto-retida por se apresentarem bem distribuídas pelo tecido gengivo-mucoso e ósseo da maxila remanescente, indicando que o sistema ERA® de retenção é adequado para reabilitação maxilar das perdas ósseas Classe II de Okay. / Searching to improve quality of life of the patients that had sustained structural maxillary loss with the necessity of rehabilitation, either through surgery or obturator prosthesis, which is a therapeutic resource to minimize functional, esthetic and psychological impairments. This study evaluated the biomechanical behavior of an Okay Class II obturator prosthesis implant retained and ERA® system, analyzing the resultant stress on the soft and bone tissue. The finite element analysis was made with a digital model constructed from a computed tomography. Four implants were positioned on the left maxillae, on the following regions: lateral incisor, canine, second premolar and first molar, with the ERA® system positioned on the extremities of a metallic bar. The software used to create the BioCAD 3D model was Rhinoceros v. 5.0, including the CAD models from the implants, UCLAS and ERA® system. The ERA® CAD model was obtained from a microCT SkyScan 1176 Bruke images, on the BMP and TIFF format. The TIFF images were exported to the img2dcm software, converted in DICOM format and finally exported to the software Invesalius, were the STL mesh was created. All mesh were imported into the software Hyperworks v. 13.0 and the post-processing was visualized on Hyperview. The force applied was of 80N over the occlusal platform and of 35N over the incisal platform. A quantitative analysis was performed, corresponding to the maximum main stress, expressed in MPa. The obturator prosthesis suffered its maximum dislocation on the region with no bone support, with the bone resection line as fulcrum. Less tension forces were observed, when comparing to compression. The forces observed were favorable to maintain the implant retained prosthesis stabilization, with good distribution over the soft and bone tissues, suggesting that the ERA® retention system is suitable to Okay Class II maxillary bone loss.
9

Ocorrência do anel de Passavant com o uso do obturador faríngeo em indivíduos com fissura de palato / Passavant´s pad occurrence with pharyngeal obturator in cleft palate subjects

Almeida, Beatriz Kuntz 11 December 2009 (has links)
Introdução: Existem evidências clínicas que o obturador faríngeo pode estimular a formação do anel de Passavant em alguns indivíduos com disfunção velofaríngea decorrente de fissura palatina, o que os tornariam melhores candidatos para correção cirúrgica dessa disfunção, ou mesmo para obterem melhores resultados com o uso do obturador faríngeo. Objetivo: O presente estudo teve por objetivo investigar a ocorrência do anel de Passavant em pacientes com fissura de palato, usuários de OF, nas seguintes condições: antes da confecção do OF (condição C1), durante a moldagem do obturador faríngeo (condição C2) e após seis meses de uso do mesmo (condição C3, sem o obturador e condição C4, com o obturador). Material e Método: A casuística deste trabalho foi composta por 25 pacientes (15 homens e 10 mulheres), com idades variando entre 18 e 59 anos (média= 32 anos). Todos os pacientes apresentavam disfunção velofaríngea após a cirurgia de palato e utilizavam obturador faríngeo havia pelo menos 6 meses. Para a avaliação do mecanismo velofaríngeo com e sem o obturador faríngeo, todos os pacientes haviam sido submetidos à avaliação nasoendoscópica durante fala. As 75 gravações dessa avaliação, 25 na condição C1, 25 na condição C2 e 25 nas condições C3 e C4, dos 25 pacientes foram editadas em um DVD e avaliadas por cinco fonoaudiólogas experientes, designadas juízas, quanto aos seguintes aspectos: a) posição do nasoendoscópio durante o exame; b) tamanho do bulbo faríngeo em relação ao espaço velofaríngeo; c) ocorrência de anel de Passavant; d) intercorrências que pudessem comprometer a visualização das paredes da faringe. Os protocolos de anotações utilizados pelas juízas foram baseados e adaptados do proposto por Golding-Kushner et al. (1990). Resultados: O grau médio de concordância intra-juízas para todos os aspectos avaliados foi considerado quase perfeito (83%) e o de concordância inter-juízas variou de regular (35%) a quase perfeito (100%). As avaliações foram comparadas entre si, nas quatro condições, para todos os aspectos avaliados. A única comparação que foi estatisticamente significante foi aquela que comparou os dados obtidos na avaliação da ocorrência do anel de Passavant entre as condições C2 e C4. Os dados revelaram que 14 (56%) pacientes apresentaram mudança na ocorrência do anel em uma ou mais das condições avaliadas e 11 (44%) não apresentaram mudança. Conclusão: Os achados deste estudo permitem concluir que o obturador faríngeo pode agir como um agente estimulador da formação do anel de Passavant em pacientes com disfunção velofaríngea decorrente de fissura palatina. / Background: Clinical evidence shows that pharyngeal obturator can stimulate Passavant´s pad formation in subjects with VPI current from cleft palate. It puts those subjects as better candidates for VPI treatment either surgical correction or pharyngeal obturator. Aim: The present study aimed to investigate Passavant´s pad occurrence in cleft palate subjects, who wore pharyngeal obturators, in the following conditions: before pharyngeal obturator´s confection (condition C1), during pharyngeal obturator molding (condition C2) and after six months wearing the pharyngeal obturator (condition C3, without the pharyngeal obturator and condition C4 with the pharyngeal obturator). Method: The sample was composed by 25 subjects (15 male and 10 female), age range between 18 - 59 years (range = 32 years). All patients had VPI current cleft palate surgery and were pharyngeal obturator wearers for at least six months. All subjects were submitted to nasoendoscopy evaluation during speech, with and without the pharyngeal obturator. The 75 recordings, 25 during condition C1, 25 during C2 and 25 during C3 and C4, were edited in a DVD and rated by five experienced speech pathologists, named judges. The judges had to rate the following aspects: a) nasoendoscope position during the exam; b) pharyngeal obturator size, according velopharyngeal space; c) Passavant´s pad occurrence; d) intercurrences that compromise pharyngeal walls observation. The judge´s rating protocols were based and adapted from the one proposed by Golding-Kushner et al. (1990). Results: Intra judge agreement for every rated aspect was considered, in range, almost perfect (83%), and the inter-judge agreement varied between regular (35%) and almost perfect (100%). The ratings were compared to each other, in every conditions, for all analyzed aspects. The only statistical significant comparison was in Passavant´s pad occurrence, between conditions C2 and C4. Data revealed that the Passavant´s pad occurrence varied, in one o more conditions, in 14 (56%) subjects and, in 11(44%) didn´t show any change. Conclusion: Findings allow us to conclude that, the pharyngeal obturator may act as a stimulus factor for Passavant´s pad formation in patients with VPI current from cleft palate.
10

Análise por meio de elementos finitos das tensões ósseas geradas por prótese obturadora maxilar implanto-retida através dos sistemas de retenção O\'ring e magneto / Finite elements analysis of bone stress generated by an implant retained maxillary obturator prosthesis with Ball/O\'ring and magnetic attachment

Pontes, Roberta Bezerra 20 September 2016 (has links)
A Análise de Elementos Finitos (AEF) vem sendo utilizada em diversos trabalhos na Odontologia, pois possibilita que o estudo in vitro simule uma situação clínica real. Neste estudo utilizou-se a Análise de Elementos Finitos para avaliar as tensões geradas por prótese total obturadora maxilar Classe II de Okay retida por implantes e utilizando os sistemas de retenção O\'ring e magneto. Avaliaram-se as tensões geradas no tecido ósseo, gengivo-mucoso e barras metálicas após a aplicação de cargas nas mesas oclusal e incisal. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo edentado adulto, onde se simulou uma perda óssea condizente com uma maxilectomia, simulando a Classe II de Okay. Foram posicionados quatro implantes na maxila, na região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, todos unidos por barra metálica onde se instalaram os sistemas de retenção escolhidos para esse estudo. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo BioCAD 3D, onde foram incorporados os modelos CAD dos implantes, UCLAS e dos sistemas de retenção, obtendo-se dois modelos, Modelo 1, O\'ring e Modelo 2, magneto. A malha de elementos finitos foi gerada pelo programa Ansys® e nela foi aplicada uma força de 80 N na plataforma oclusal e 35 N na plataforma incisal, simultaneamente. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal e os valores quantitativos expressos em MPa. O deslocamento da prótese obturadora, no sentido da região sem suporte ósseo, foi maior no Modelo 1, O\'ring. A mucosa de revestimento, o osso cortical e o osso medular sofreram tensões de tração e compressão que variaram de acordo com o sistema de retenção utilizado, sendo que o Modelo 2, magnetos, transferiu mais tensões para essas estruturas. O Modelo 2, magnetos, apresentou tensões na região cervical de três implantes, enquanto o Modelo 1, O\'ring, apresentou somente em um implante. A barra metálica com retenções do tipo magneto sofreu tensões equivalentes de von Mises com valores semelhantes a barra metálica com O\'ring, no entanto a área envolvida foi maior em abrangência. Baseando-se nos resultados apresentados neste estudo, a utilização de ambos sistemas de retenção é indicada para reabilitação com próteses obturadoras implantorretidas, no entanto o modelo que utilizou retenção com O\'ring, apresentou comportamento biomecânico mais favorável para esse tipo de reabilitação. / The Finite Elements Analysis (FEA) has been used in several studies in Dentistry, as it allows that an in vitro study simulates a clinical scenario. In this study the Finite Element Analysis was used to evaluate the bone stress generated by an Okay Class II obturator implant retained prosthesis having Ball/O\'ring and magnetic attachment. The tensions generated over bone, soft tissue and metallic bars were evaluated after applied loads which simulated the masticatory activity. The Finite Elements Analysis, were done utilizing a digital model developed from a computer tomography of an adult subject, where it was simulated a bone loss in accordance with a maxillectomy, simulating an Okay Class II. Four implants were set in the left maxilla, on the lateral incisor, canine, second premolar and first molar, all linked by a metallic bar where the retention system chosen for this study was installed. The Rhinoceros® program, version 5.0 was used to generate the BioCAD 3D model, where the implant CAD models, UCLAS and retention systems were incorporated, obtaining two models, Model 1, Ball/O\'ring and Model 2, magnetic attachment. The finite elements mesh was generated by Ansys® program and an 80 N force was applied over it on the occlusal platform and 35 N on the incisal platform. A qualitative analysis was performed, corresponding to the maximum main stress and the quantitative values expressed on MPa. The obturator prosthesis movement in the direction of the area without the bone support was greater on the Model 1, O´Ring. The soft tissue, the cortical and medullar bones suffered compression and tensions which variated according with the retention system used, the Model 2, magnetic attachment, was the one transferring more stress to these structures. The Model 2, magnetic attachment, presented tensions on the cervical region at 03 implants, while the Model 1, Ball/O\'ring, presented only at one implant. The metallic bar with magnetic attachment suffered von Mises equivalent tensions with similar values to the metallic bar with Ball/O\'ring, however it covered a greater area. Based on the results obtained in this study, the use of both retention systems is indicated in the rehabilitation with implant retained obturator prosthesis, though the Model 1, Ball/O\'ring, presented a biomechanical behavior more suitable to this type of rehabilitation.

Page generated in 0.0997 seconds