• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 3
  • 1
  • Tagged with
  • 12
  • 12
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A numerical and analytical investigation into some mechanical aspects of adhesive dentistry

Hubsch, Pierre Francois January 1995 (has links)
No description available.
2

Avaliação da hiperestesia dentinária após tratamento em diferentes formulações à base de oxalato de potássio utilizando-se um placebo como controle.

Martineli, Ana Christina Bonato Figueiredo 24 June 1999 (has links)
A hiperestesia dentinária é uma das mais antigas queixas de desconforto dos pacientes e, devido à sua alta incidência e diversidade de tratamentos sugeridos na literatura, novos produtos devem ser avaliados quanto ao efeito e aplicabilidade. O propósito deste estudo foi avaliar as respostas imediata e mediata de 94 dentes (caninos e pré-molares), que apresentavam algum grau de sensibilidade dentinária (1, 2 ou 3) de acordo com a Escala de Medida Verbal (EMV) aos estímulos sonda e ar, após a aplicação de três formulações à base de oxalato de potássio: Oxa-Gel®, Solução Experimental 1 e Solução Experimental 2, tendo um placebo como controle. Cada formulação de oxalato de potássio e o placebo foram aplicados passivamente por 3 minutos na superfície da dentina úmida, sendo o excesso de material removido posteriormente. O grau de sensibilidade foi avaliado antes (baseline) e imediatamente após a aplicação de cada formulação com um intervalo de 7 dias. Os resultados obtidos após a quarta aplicação foram denominados resultados imediatos e, após 6 meses, resultados mediatos. Os escores foram submetidos à análise estatística através dos testes de Kruskal-Wallis e de Friedman two-way ANOVA (p< 0,05). A aplicação de todos os materiais, inclusive o placebo, independente do tempo avaliado e dos estímulos utilizados, resultou em uma redução estatisticamente significante na hiperestesia dentinária podendo essa redução prolongar-se até seis meses. Houve uma tendência de respostas mais severas ao estímulo ar quando comparado ao estímulo sonda antes do tratamento, sendo que a hiperestesia provocada pela sonda se mostrou mais persistente ao longo do tratamento. O tratamento da hiperestesia dentinária está sujeito a variáveis clínicas que podem aumentar ou diminuir o efeito anti-hiperestésico dos agentes estudados.
3

Estudo sobre o papel dos solventes na produção de união à dentina / The role of solvents on bonding to dentin

Garcia, Fernanda Cristina Pimentel 07 April 2005 (has links)
O presente estudo teve por objetivo avaliar o efeito das interações moleculares entre solventes e monômeros com a matriz de dentina desmineralizada, nas alterações das propriedades mecânicas, na taxa de evaporação e na resistência de união (RU). As propriedades mecânicas da dentina desmineralizada foram determinadas através da análise do módulo de elasticidade máximo aparente (EMax) e do relaxamento das tensões (RT). Os resultados permitiram concluir que o Emax foi dependente do tipo de solvente utilizado e do tempo. A taxa de enrijecimento da matriz desmineralizada foi maior para acetona e etanol, intermediária para o ar, metanol e propanol, menor para o HEMA e praticamente nenhuma para água. Da mesma forma, o RT dependeu da solução em que os espécimes foram equilibrados, previamente ao ensaio mecânico, e do tipo de deformação induzida ao espécime. De uma maneira geral, a resposta da matriz desmineralizada (RT) foi maior quando equilibrada em acetona, propanol e etanol, intermediária para HEMA, butanol e metanol e menor para água. A tensão máxima gerada com o tempo foi maior quanto maior a deformação inicial induzida (3-5-10%). A taxa de evaporação e a perda de massa total (%) de misturas experimentais à base de 35%HEMA/65%solventes foram determinadas através da medida de perda de massa em função do tempo, a partir de duas superfícies distintas (cubos de dentina desmineralizados x superfície livre). A taxa de evaporação e a perda de massa foi maior para HEMA/acetona (H/AC) e HEMA/metanol (H/M), intermediária para HEMA/etanol (H/E) e menor para HEMA/água (H/A), sendo esses valores superiores a partir dos cubos de dentina. A RU foi determinada pelo emprego do teste de microtração. Para verificar a influência do aspecto de brilho superficial, foram aplicadas 2 ou 3 camadas de misturas experimentais (35%HEMA/65%solventes) sobre a dentina previamente condicionada. Os maiores valores de RU foram obtidos com a manutenção do brilho superficial para todas as soluções testadas (ou seja, com a aplicação de 3 camadas). A durabilidade da RU obtida com o uso das soluções experimentais (35%HEMA/65%solventes) aplicadas sobre dentina desmineralizada seca foi avaliada após 24hs , 6 meses ou 1 ano de armazenagem em água deionizada. O valor de RU sofreu uma redução com a referida armazenagem para a maioria das soluções testadas. Os maiores valores de RU foram obtidos para H/M e H/E em todos os períodos avaliados. Este estudo desenvolveu uma linha de raciocínio que empregou a teoria dos parâmetros de solubilidade para descrever e analisar as interações moleculares que ocorrem durante a execução de um procedimento adesivo à dentina, procurando estabelecer as relações de causa e efeito. / The present study aimed to test the effect of the molecular interactions between solvent and pure monomers with demineralized dentin matrix on its mechanical properties, evaporation rate and consequent change in the bond strength (BS). The mechanical properties were determined by measuring the apparent maximum modulus of elasticity (EMax) and stress relaxation (SR). The results indicated that the Emax is both time and solvent dependent; accordingly, the SR was both strain and solvent dependent. The weight loss (%) and evaporation rate of experimental mixtures (35%HEMA/65%solvents) were determined by the measuring of weight loss over time from different surfaces (demineralized dentin cubes x free surface). The overall evaporation rate and weight loss were higher for dentin cubes and dependent of solvents. The bond strength (BS) was determined by the microtensile test. The effects of surface shininess on bond strength of experimental primers to dentin were evaluated. Dentin surfaces were acidetched, primed with experimental mixtures in two (not shiny) or three (shiny) coats. For the all primers the presence of a shiny surface significantly improved resin-dentin bond strengths. The influence of storage time in resin dentin bond strength mediated by experimental HEMA/solvent primers was determined. Part of specimens were tested after 24 hour storage in deionized water (control) and remaining specimens were tested after 6 months and 1 year of storage in the same condition. Water storage resulted in reduced bond strength for most of the primers. This study develops a rationale that employs the solubility parameter theory to describe and analyze molecular interactions that occur during adhesive procedure to dentin, seeking to establish the cause-effect relationship.
4

Estudo sobre o papel dos solventes na produção de união à dentina / The role of solvents on bonding to dentin

Fernanda Cristina Pimentel Garcia 07 April 2005 (has links)
O presente estudo teve por objetivo avaliar o efeito das interações moleculares entre solventes e monômeros com a matriz de dentina desmineralizada, nas alterações das propriedades mecânicas, na taxa de evaporação e na resistência de união (RU). As propriedades mecânicas da dentina desmineralizada foram determinadas através da análise do módulo de elasticidade máximo aparente (EMax) e do relaxamento das tensões (RT). Os resultados permitiram concluir que o Emax foi dependente do tipo de solvente utilizado e do tempo. A taxa de enrijecimento da matriz desmineralizada foi maior para acetona e etanol, intermediária para o ar, metanol e propanol, menor para o HEMA e praticamente nenhuma para água. Da mesma forma, o RT dependeu da solução em que os espécimes foram equilibrados, previamente ao ensaio mecânico, e do tipo de deformação induzida ao espécime. De uma maneira geral, a resposta da matriz desmineralizada (RT) foi maior quando equilibrada em acetona, propanol e etanol, intermediária para HEMA, butanol e metanol e menor para água. A tensão máxima gerada com o tempo foi maior quanto maior a deformação inicial induzida (3-5-10%). A taxa de evaporação e a perda de massa total (%) de misturas experimentais à base de 35%HEMA/65%solventes foram determinadas através da medida de perda de massa em função do tempo, a partir de duas superfícies distintas (cubos de dentina desmineralizados x superfície livre). A taxa de evaporação e a perda de massa foi maior para HEMA/acetona (H/AC) e HEMA/metanol (H/M), intermediária para HEMA/etanol (H/E) e menor para HEMA/água (H/A), sendo esses valores superiores a partir dos cubos de dentina. A RU foi determinada pelo emprego do teste de microtração. Para verificar a influência do aspecto de brilho superficial, foram aplicadas 2 ou 3 camadas de misturas experimentais (35%HEMA/65%solventes) sobre a dentina previamente condicionada. Os maiores valores de RU foram obtidos com a manutenção do brilho superficial para todas as soluções testadas (ou seja, com a aplicação de 3 camadas). A durabilidade da RU obtida com o uso das soluções experimentais (35%HEMA/65%solventes) aplicadas sobre dentina desmineralizada seca foi avaliada após 24hs , 6 meses ou 1 ano de armazenagem em água deionizada. O valor de RU sofreu uma redução com a referida armazenagem para a maioria das soluções testadas. Os maiores valores de RU foram obtidos para H/M e H/E em todos os períodos avaliados. Este estudo desenvolveu uma linha de raciocínio que empregou a teoria dos parâmetros de solubilidade para descrever e analisar as interações moleculares que ocorrem durante a execução de um procedimento adesivo à dentina, procurando estabelecer as relações de causa e efeito. / The present study aimed to test the effect of the molecular interactions between solvent and pure monomers with demineralized dentin matrix on its mechanical properties, evaporation rate and consequent change in the bond strength (BS). The mechanical properties were determined by measuring the apparent maximum modulus of elasticity (EMax) and stress relaxation (SR). The results indicated that the Emax is both time and solvent dependent; accordingly, the SR was both strain and solvent dependent. The weight loss (%) and evaporation rate of experimental mixtures (35%HEMA/65%solvents) were determined by the measuring of weight loss over time from different surfaces (demineralized dentin cubes x free surface). The overall evaporation rate and weight loss were higher for dentin cubes and dependent of solvents. The bond strength (BS) was determined by the microtensile test. The effects of surface shininess on bond strength of experimental primers to dentin were evaluated. Dentin surfaces were acidetched, primed with experimental mixtures in two (not shiny) or three (shiny) coats. For the all primers the presence of a shiny surface significantly improved resin-dentin bond strengths. The influence of storage time in resin dentin bond strength mediated by experimental HEMA/solvent primers was determined. Part of specimens were tested after 24 hour storage in deionized water (control) and remaining specimens were tested after 6 months and 1 year of storage in the same condition. Water storage resulted in reduced bond strength for most of the primers. This study develops a rationale that employs the solubility parameter theory to describe and analyze molecular interactions that occur during adhesive procedure to dentin, seeking to establish the cause-effect relationship.
5

Emulsão de Copaifera Multijuga Hayne para limpeza de preparo Cavitário: controle de qualidade físico-químico e avaliação da atividade antibacteriana

Milério, Patricia Sâmea Lêdo Lima 20 January 2015 (has links)
Submitted by Maryse Santos (maryseeu4@gmail.com) on 2016-09-02T14:20:50Z No. of bitstreams: 1 Dissertação de mestrado- Patrícia Lêdo Lima Milério.pdf: 3829550 bytes, checksum: 0550e92088a763e371aab2565977a3c2 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-17T20:13:52Z (GMT) No. of bitstreams: 1 Dissertação de mestrado- Patrícia Lêdo Lima Milério.pdf: 3829550 bytes, checksum: 0550e92088a763e371aab2565977a3c2 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-17T20:14:24Z (GMT) No. of bitstreams: 1 Dissertação de mestrado- Patrícia Lêdo Lima Milério.pdf: 3829550 bytes, checksum: 0550e92088a763e371aab2565977a3c2 (MD5) / Made available in DSpace on 2017-07-17T20:14:24Z (GMT). No. of bitstreams: 1 Dissertação de mestrado- Patrícia Lêdo Lima Milério.pdf: 3829550 bytes, checksum: 0550e92088a763e371aab2565977a3c2 (MD5) Previous issue date: 2015-01-20 / FAPEAM / This study analyzed the stability and antibacterial activity of an emulsion in based of copaiba oil(Copaifera multijuga Hayne) in 10% for cavity cleaning, according to the physicochemical properties of quality control and antibacterial activity, following the standardization of guidelines and standards good manufacturing practices of the Brazilian Pharmacopoeia and the National Health Surveillance Agency. For quality control, the emulsion test was stored in different environments (greenhouse, room temperature, room temperature protected from light, a place with air conditioning, fridge and freezer) and evaluated in different periods (from 0.3 to 6 months ). There were, with this emulsion, centrifuge tests, determination of pH, density, microbiological evaluation and organoleptic. The antibacterial activity of the formulations on the microorganisms Streptococcus mutans (ATCC25175), Streptococcus oralis (ATCC10557), Streptococcus salivarius (ATCC7073) and Lactobacillus paracasei (ATCC335) was analyzed by using the minimum inhibitory concentration tests and minimum bactericidal. The results of the pH test and density determination were analyzed by ANOVA and Bonferroni's test (p <0.05). The other tests were given descriptive analysis In the centrifugation test, there was no phase separation at time 0 in the time of three months, stored in freezer, fridge and air conditioning and time of six months, stored in freezer, fridge, while in other environments in different times there was phase separation; in the pH test, the greenhouse storage environment, room temperature protected from light, room temperature and air conditioning had statistically significant difference from the control group (time 0), fridge and freezer in experimental periods; in the density test, the greenhouse had the lowest density values and showed a statistically significant difference in relation to: control group (zero time), time 3 months (fridge, freezer and air conditioning) and time 6 months (fridge and freezer); in microbiological evaluation there was no bacterial growth; in organoleptic evaluation at time 0 no had change, in time of 3 months, there was only change in color of the emulsion stored in glass and in time of 6 months, a change in color of the emulsion stored in room temperature and in room temperature protected of light. The emulsion test showed bacteriostatic and bactericidal activity, respectively, in concentrations of 13,33μL/ml and 15 μL/ml for S. mutans; 20 μL/ml and 23,33 μL/mL for S. salivarius and 13,33 μL/ml and 15 μL/ml for L. paracasei. The lowest concentration of the test emulsion (8,33μL/ml) demonstrated bactericidal activity against S. oralis. In conclusion, the emulsion showed antibacterial activity against all tested microorganisms; presented conditions of stability and quality without contaminants in freezer and in fridge. Considering, for the daily clinic, the best environment is the refrigerator. / Este estudo analisou a estabilidade e atividade antibacteriana de uma emulsão à base de óleo de copaíba (Copaifera multijuga Hayne) a 10% para limpeza de cavidade, segundo as propriedades físico-químicas de controle de qualidade e atividade antibacteriana, obedecendo às orientações de padronização e normas das boas práticas de fabricação da Farmacopeia Brasileira e da Agência Nacional de Vigilância Sanitária. Para o controle de qualidade, a emulsão-teste foi armazenada em diferentes ambientes (estufa, temperatura ambiente, temperatura ambiente ao abrigo da luz, local com ar condicionado, geladeira e freezer) e avaliada em diferentes períodos experimentais (0,3 e 6 meses). Realizaram-se, com essa emulsão, testes de centrifugação, determinação de pH, densidade, avaliação microbiológica e organoléptica. A atividade antibacteriana das formulações sobre os microrganismos Streptococcus mutans (ATCC25175), Streptococcus oralis (ATCC10557), Streptococcus salivarius (ATCC7073) e Lactobacillus paracasei (ATCC335) foi analisada através dos testes de concentração inibitória mínima e bactericida mínima. Os resultados do teste de pH e determinação da densidade foram analisados pelo teste ANOVA e teste de Bonferroni (p < 0,05). Os demais testes receberam análise descritiva. Na centrifugação, não foi observado separação de fases no tempo 0, no tempo de 3 meses, armazenados em freezer, geladeira e ar-condicionado e no tempo de 6 meses, armazenados em freezer, geladeira, enquanto que nos outros ambientes nos diferentes tempos houve separação de fases; no teste de pH, o ambiente de armazenamento estufa, temperatura ambiente ao abrigo da luz, temperatura ambiente e ar-condicionado apresentaram diferença estatisticamente significativa em relação ao grupo controle (tempo 0), geladeira e freezer nos períodos experimentais; na densidade, o ambiente de armazenamento estufa apresentou os menores valores de densidade e mostrou diferença estatisticamente significante em relação ao: grupo controle (tempo zero), tempo 3 meses (geladeira, freezer e ar-condicionado) e tempo 6 meses (geladeira e freezer); na avaliação microbiológica não houve crescimento bacteriano; na avaliação organoléptica, no tempo 0 não houve qualquer alteração, no tempo de 3 meses, houve apenas alteração da coloração da emulsão armazenada em estufa e no tempo de 6 meses, houve alteração da coloração da emulsão armazenada em estufa, temperatura ambiente e ao abrigo da luz. A emulsão-teste apresentou atividade bacteriostática e bactericida, respectivamente, nas concentrações de 13,33μL/mL e 15 μL/mL para o S. mutans; 20 μL/mL e 23,33 μL/mL para S. salivarius e 13,33 μL/mL e 15 μL/mL para o L. paracasei. A menor concentração da emulsão-teste (8,33μL/mL) demonstrou atividade bactericida contra S. oralis. Conclui-se que, a emulsão-teste demonstrou atividade antibacteriana frente a todos os microrganismos ensaiados; apresentou condições de estabilidade e qualidade, sem contaminantes, nos ambientes de armazenamento freezer e geladeira. Considerando a clínica diária o melhor ambiente de armazenamento é a geladeira.
6

Odontologia digital: estudo da concordância entre avaliação clínica e fotográfica de restaurações de resina composta / Digital dentistry: study of the agreement between clinical and photographic assessments on composite resin restorations

Cecilia Vilela Matias Vasconcelos 01 December 2017 (has links)
O presente estudo teve por objetivo observar os níveis de concordância entre a avaliação clínica e fotográfica digital no diagnóstico de desempenho de restaurações posteriores (Classe I e Classe II) em resina composta. As avaliações clínicas foram feitas por dois examinadores (C1 e C2) calibrados (e-calib) usando critérios da Fédération Dentaire Internationale (FDI) considerando propriedades estéticas, funcionais e biológicas. Em cada momento de avaliação clínica, uma fotografia digital padronizada de cada restauração foi realizada. Dois examinadores digitais (D1 e D2), igualmente calibrados e usando os mesmos critérios avaliaram todas as imagens obtidas nas avaliações clínicas. Os dados foram analisados com Coeficiente de Cohen Kappa e teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Comparações intra (mesmo método) e inter (métodos diferentes) examinadores foram feitas. Os resultados revelaram que os níveis de concordância variaram de \"Perfeito\" a \"Justo\". Houve diferença significante (p < 0.05) intra-examinadores; entre C1 e C2 para o manchamento marginal; entre D1 e D2 para brilho superficial, estabilidade de cor e translucidez, forma anatômica, e fratura do material e retenção; inter-examinadores foram encontradas diferenças significantes em todas as propriedades estéticas (brilho superficial, manchamento marginal, estabilidade de cor e translucidez e forma anatômica) e funcionais (fratura do material e retenção e adaptação marginal) observadas. A associação entre a imagem digital e o exame clínico pode ser uma ferramenta promissora para detecção de falhas precoces em restaurações de resina composta, necessitando de mais estudos que investiguem o método digital. / The present study aimed to evaluate the agreement levels between clinical and digital photographic assessments on the performance of posterior composite resin restorations (Class I and Class II). The clinical assessments were made by two examiners (C1 and C2) calibrated through e-calib with the Fédération Dentaire Internationale (FDI) criteria considering esthetic, functional and biological properties. In each moment of clinical assessment, standard digital photographs of each restoration were obtained. Two digital examiners (D1 and D2), equally calibrated and using the same criteria, evaluated all the images obtained in the clinical assessment. The data were analyzed with the calculation of Cohen Kappa coefficient, Kruskal-Wallis non-parametric test and Dunn\'s multiple shared test, with significance of 5%. Intra (same method) and inter (different methods) comparisons were realized. The results showed that agreement levels varied from \"Perfect\" to \"Fair\". There was a significant difference (p < 0.05) intra-examiners; between C1 and C2 to the marginal staining parameter; between D1 and D2 in the parameters surface luster, colour match and translucency, esthetic anatomical form and fracture of material and retention; inter-examiners was noticed significant difference in all the esthetic (surface luster, colour match and translucency, marginal staining, esthetic anatomical form) and functional properties (fracture of material and retention and marginal adaptation) observed. The association between the digital image to the clinical exam may be a promising tool associated with the clinical method to detect early failures in composite resin restorations, requiring further studies investigating the digital method.
7

Minimally invasive dentistry approach in dental public health

Oliveira, Deise Cruz 01 May 2011 (has links)
Dental caries is the main reason for placement and replacement of restorations (Keene, 1981). More than 60 percent of dentists' restorative time is spent replacing existing restorations. The replacement of restorations can result in a cavity preparation larger than its predecessor which leads to weakening of the remaining tooth structure (Mjör, 1993). Considering the traditional surgical dental caries management philosophy, it was based on "extension for prevention" and restorative material needs rather than on preserving the healthy tooth structure (Black, 1908). In the 1970s, the surgical dental paradigm began shifting to a new approach for caries management: Minimally Invasive Dentistry (MID). It was based on the medical model that prioritizes caries risk assessment, early caries detection, remineralization of tooth structure, and especially preservation of tooth structure through minimal intervention in the placement and replacement of restorations (Yamaga et al, 1972). The minimal intervention paradigm emphasizes use of adhesive restorative materials in order to minimize the size of cavity preparation (Murdoch-Kinch & McLean, 2003). Hence, a cross-sectional study using an online survey instrument (30-item) was conducted among National Network for Oral Health Access (NNOHA) and American Association Community Dental Programs (AACDP) members. Besides demographics, the survey addressed the following items using a 5-point Likert scale: knowledge, attitudes and behavior concerning MID among general practitioners. Specific questions focused on practitioner and practice characteristics, previous training and knowledge of MID, knowledge use of restorative, diagnostic and preventive techniques and whether MID was considered to meet the standard of care in the U.S., which was the main outcome of the study. Chi-square, Fisher's exact test, Wilcoxon rank-sum test, and two-Sample t-test were used to identify factors associated with beliefs that MID meets the standard of care. Overall, 86% believed MID met the standard of care for primary teeth, and 77% believed this for permanent teeth. The study found that those with more favorable opinions of fluoride to be more likely to believe MID met the standard of care, but no demographic or practice characteristics were associated MID standard of care beliefs.
8

Odontologia digital: estudo da concordância entre avaliação clínica e fotográfica de restaurações de resina composta / Digital dentistry: study of the agreement between clinical and photographic assessments on composite resin restorations

Vasconcelos, Cecilia Vilela Matias 01 December 2017 (has links)
O presente estudo teve por objetivo observar os níveis de concordância entre a avaliação clínica e fotográfica digital no diagnóstico de desempenho de restaurações posteriores (Classe I e Classe II) em resina composta. As avaliações clínicas foram feitas por dois examinadores (C1 e C2) calibrados (e-calib) usando critérios da Fédération Dentaire Internationale (FDI) considerando propriedades estéticas, funcionais e biológicas. Em cada momento de avaliação clínica, uma fotografia digital padronizada de cada restauração foi realizada. Dois examinadores digitais (D1 e D2), igualmente calibrados e usando os mesmos critérios avaliaram todas as imagens obtidas nas avaliações clínicas. Os dados foram analisados com Coeficiente de Cohen Kappa e teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Comparações intra (mesmo método) e inter (métodos diferentes) examinadores foram feitas. Os resultados revelaram que os níveis de concordância variaram de \"Perfeito\" a \"Justo\". Houve diferença significante (p < 0.05) intra-examinadores; entre C1 e C2 para o manchamento marginal; entre D1 e D2 para brilho superficial, estabilidade de cor e translucidez, forma anatômica, e fratura do material e retenção; inter-examinadores foram encontradas diferenças significantes em todas as propriedades estéticas (brilho superficial, manchamento marginal, estabilidade de cor e translucidez e forma anatômica) e funcionais (fratura do material e retenção e adaptação marginal) observadas. A associação entre a imagem digital e o exame clínico pode ser uma ferramenta promissora para detecção de falhas precoces em restaurações de resina composta, necessitando de mais estudos que investiguem o método digital. / The present study aimed to evaluate the agreement levels between clinical and digital photographic assessments on the performance of posterior composite resin restorations (Class I and Class II). The clinical assessments were made by two examiners (C1 and C2) calibrated through e-calib with the Fédération Dentaire Internationale (FDI) criteria considering esthetic, functional and biological properties. In each moment of clinical assessment, standard digital photographs of each restoration were obtained. Two digital examiners (D1 and D2), equally calibrated and using the same criteria, evaluated all the images obtained in the clinical assessment. The data were analyzed with the calculation of Cohen Kappa coefficient, Kruskal-Wallis non-parametric test and Dunn\'s multiple shared test, with significance of 5%. Intra (same method) and inter (different methods) comparisons were realized. The results showed that agreement levels varied from \"Perfect\" to \"Fair\". There was a significant difference (p < 0.05) intra-examiners; between C1 and C2 to the marginal staining parameter; between D1 and D2 in the parameters surface luster, colour match and translucency, esthetic anatomical form and fracture of material and retention; inter-examiners was noticed significant difference in all the esthetic (surface luster, colour match and translucency, marginal staining, esthetic anatomical form) and functional properties (fracture of material and retention and marginal adaptation) observed. The association between the digital image to the clinical exam may be a promising tool associated with the clinical method to detect early failures in composite resin restorations, requiring further studies investigating the digital method.
9

Mechanical and physical properties assessment of Bulk Fill resin composites / Avaliação das propriedades físico-mecânicas de resinas compostas do tipo Bulk Fill

Rizzante, Fabio Antonio Piola 04 May 2018 (has links)
The achievement of predictable and long lasting adhesive restorations in posterior teeth have always been a major objective of studies in the context of materials and techniques development. The use of bulk fill composites could provide better outcomes, but it is important to assess their physico-mechanical properties, responsible for their clinical behavior. The purpose of the present study was to assess the mechanical and physical properties of bulk fill composites. The composites were divided into 2 groups according to their viscosity. For low viscosity composites, the present study assessed: Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF), and Filtek Z350XT Flow (Z3F- control); and for high viscosity composites: Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Fusion x-tra (ADM) and Filtek Z350 XT (Z3XT- control). Composites were assessed through shrinkage stress test (using 12 and 24mm3 of composite in a custom device adapted in an Universal Testing Machine); volumetric shrinkage (using 64mm3 of composite placed on a Teflon mold and scanned in a micro computed tomography/CT); Youngs modulus (through a 3-point bending test device adapted in an Universal Testing Machine); microhardness and depth of cure tests (using longitudinal Knoop microhardness). All data was evaluated regarding their homogeneity using Shapiro-Wilk test. For polymerization stress, 3-way Variance Analysis (ANOVA) was used. Considering Volumetric Shrinkage, Youngs Modulus, Microhardness and Depth of Cure, one-way ANOVA was used. All ANOVA tests were followed by Tukeys test and 5% was adopted as significance level. Shrinkage stress test with 12mm3 showed SDR, TBF and XF generating the lowest stress after 300s, followed by other high viscosity composites (ADM, FBF, XB and FBP/Z3XT). The regular low viscosity composite (Z3F) generated the highest stress for all assessed times. Considering the same test, with 24mm3, after 300s, SDR, FBP and ADM generated similar stress, followed by TBF and XF. Low viscosity bulk fill composites generated lower stress than Z3F. Considering Youngs modulus, low viscosity composites (SDR, FBF, XB and Z3F) showed the lowest values, followed by ADM and TBF. The other high viscosity composites (Z3XT, FBP and XF) showed the highest values. For microhardness test, all low viscosity composites showed lower values (FBF being the lowest). For high viscosity composites, Z3XT showed the highest values, followed by XF, FBP/TBF and ADM. Assessing depth of cure, regular composites showed lower values when compared with bulk fill composites. All bulk fill composites showed adequate depth of cure over 4.5mm (microhardness 80% of initial reading). SDR and XB showed the highest depth of cure. All high viscosity bulk fill composites generated lower volumetric shrinkage than regular composites. All low viscosity bulk fill composites showed similar volumetric shrinkage when compared to the regular composites (Z3F and Z3XT). Bulk fill composites show characteristics that allow their use in larger increments (i.e. volumetric shrinkage and polymerization stress similar or lower when compared with regular composites). Nonetheless, the mechanical properties of bulk fill composites were widely variable, being important to individually assess each material previously to its clinical application. / A obtenção de restaurações adesivas previsíveis e duradouras em dentes posteriores sempre foi objetivo de estudos na área de desenvolvimento de materiais e técnicas. O uso de resinas compostas do tipo bulk fill pode possibilitar melhores resultados, porém é importante o estudo de suas propriedades físico-mecânicas, responsáveis por seus comportamentos clínicos. O objetivo do presente estudo foi o de avaliar as propriedades físicas e mecânicas das resinas bulk fill. As resinas foram divididas em 2 grupos de acordo com sua viscosidade. Para resinas de baixa viscosidade, o presente estudo avaliou: Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF) e Filtek Z350XT Flow (Z3F-controle); e, para alta viscosidade: Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Fusion x-tra (ADM) e Filtek Z350 XT (Z3XT-controle). As resinas foram avaliadas em relação à tensão de polimerização (utilizando 12 e 24mm3 de resina adaptadas em um dispositivo adaptado a uma máquina de testes universal); contração volumétrica (utilizando 64mm3 de resina composta inserida em um molde de Teflon e escaneada em um micro-tomógrafo/CT), modulo de Young (através de um dispositivo de flexão em 3 pontos adaptado a uma máquina de testes universal), microdureza e profundidade de polimerização (utilizando microdureza Knoop). Todos os resultados foram avaliados em relação à homogeneidade utilizando o teste de Shapiro-Wilk. Para avaliação da tensão de polimerização, foi empregada a Análise de Variância (ANOVA) a 3 critérios. Para as analyses de contração volumétrica, Módulo de Young, microdureza e profundidade de polimerizaçao, ANOVA a um critério foi empregada. Todas as Análises de Variância foram seguidas pelo teste de Tukey e 5% foi adotado como nível de significância. A tensão de polimerização com 12mm3 demonstrou que SDR, TBF e XF geraram valores significantemente mais baixos após 300s, seguidas por outras resinas de alta viscosidade (ADM, FBF, XB e FBP/Z3XT). A resina convencional de baixa viscosidade (Z3F) gerou valores de tensão significantemente mais elevados para todos os tempos avaliados. Considerando o mesmo teste, com 24mm3, após 300s, SDR, FBP e ADM geraram valores estatisticamente inferiores, seguidas por TBF e XF. As resinas bulk fill de baixa visocidade geraram menor tensão de polimerização que a Z3F. Considerando o modulo de Young, resinas de baixa viscosidade (SDR, FBF, XB e Z3F) apresentaram valores significantemente inferiores, seguidas por ADM e TBF. As outras resinas de alta viscosidade (Z3XT, FBP e XF) apresentaram valores significantemente mais elevados. Para o teste de microdureza, todas as resinas de baixa viscosidade apresentaram valores inferiores (FBF apresentou o menor). Para as resinas de alta viscosidade, Z3XT apresentou os valores mais elevados, seguida por XF, FBP/TBF e ADM. Para profundidade de polimerização, resinas compostas convencionais apresentaram valores signifixantemente mais baixos quando comparadas com resinas bulk fill. Todas as resinas bulk fill apresentaram profundidade de polimerização adequada até pelo menos 4,5mm (microdureza 80% da leitura inicial/superfície). SDR e XB apresentaram os valores mais altos de profundidade de polimerização. Todas as resinas bulk fill de alta viscosidade geraram menor contração volumétrica que resinas compostas convencionais. Todas as resinas bulk fill de baixa viscosidade apresentaram contração volumétrica similar às resinas convencionais (Z3F e Z3XT). Resinas compostas bulk fill apresentaram características que possibilitam sua indicação para serem empregadas em grandes incrementos (contração volumétrica e tensão de polimerização similar ou inferiores às resinas convencionais, além de maior profundidade de polimerização). No entanto, as propriedades mecânicas variaram grandemente entre as resinas estudadas sendo importante uma avaliação individual de cada material previamente ao seu uso clínico.
10

Mechanical and physical properties assessment of Bulk Fill resin composites / Avaliação das propriedades físico-mecânicas de resinas compostas do tipo Bulk Fill

Fabio Antonio Piola Rizzante 04 May 2018 (has links)
The achievement of predictable and long lasting adhesive restorations in posterior teeth have always been a major objective of studies in the context of materials and techniques development. The use of bulk fill composites could provide better outcomes, but it is important to assess their physico-mechanical properties, responsible for their clinical behavior. The purpose of the present study was to assess the mechanical and physical properties of bulk fill composites. The composites were divided into 2 groups according to their viscosity. For low viscosity composites, the present study assessed: Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF), and Filtek Z350XT Flow (Z3F- control); and for high viscosity composites: Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Fusion x-tra (ADM) and Filtek Z350 XT (Z3XT- control). Composites were assessed through shrinkage stress test (using 12 and 24mm3 of composite in a custom device adapted in an Universal Testing Machine); volumetric shrinkage (using 64mm3 of composite placed on a Teflon mold and scanned in a micro computed tomography/CT); Youngs modulus (through a 3-point bending test device adapted in an Universal Testing Machine); microhardness and depth of cure tests (using longitudinal Knoop microhardness). All data was evaluated regarding their homogeneity using Shapiro-Wilk test. For polymerization stress, 3-way Variance Analysis (ANOVA) was used. Considering Volumetric Shrinkage, Youngs Modulus, Microhardness and Depth of Cure, one-way ANOVA was used. All ANOVA tests were followed by Tukeys test and 5% was adopted as significance level. Shrinkage stress test with 12mm3 showed SDR, TBF and XF generating the lowest stress after 300s, followed by other high viscosity composites (ADM, FBF, XB and FBP/Z3XT). The regular low viscosity composite (Z3F) generated the highest stress for all assessed times. Considering the same test, with 24mm3, after 300s, SDR, FBP and ADM generated similar stress, followed by TBF and XF. Low viscosity bulk fill composites generated lower stress than Z3F. Considering Youngs modulus, low viscosity composites (SDR, FBF, XB and Z3F) showed the lowest values, followed by ADM and TBF. The other high viscosity composites (Z3XT, FBP and XF) showed the highest values. For microhardness test, all low viscosity composites showed lower values (FBF being the lowest). For high viscosity composites, Z3XT showed the highest values, followed by XF, FBP/TBF and ADM. Assessing depth of cure, regular composites showed lower values when compared with bulk fill composites. All bulk fill composites showed adequate depth of cure over 4.5mm (microhardness 80% of initial reading). SDR and XB showed the highest depth of cure. All high viscosity bulk fill composites generated lower volumetric shrinkage than regular composites. All low viscosity bulk fill composites showed similar volumetric shrinkage when compared to the regular composites (Z3F and Z3XT). Bulk fill composites show characteristics that allow their use in larger increments (i.e. volumetric shrinkage and polymerization stress similar or lower when compared with regular composites). Nonetheless, the mechanical properties of bulk fill composites were widely variable, being important to individually assess each material previously to its clinical application. / A obtenção de restaurações adesivas previsíveis e duradouras em dentes posteriores sempre foi objetivo de estudos na área de desenvolvimento de materiais e técnicas. O uso de resinas compostas do tipo bulk fill pode possibilitar melhores resultados, porém é importante o estudo de suas propriedades físico-mecânicas, responsáveis por seus comportamentos clínicos. O objetivo do presente estudo foi o de avaliar as propriedades físicas e mecânicas das resinas bulk fill. As resinas foram divididas em 2 grupos de acordo com sua viscosidade. Para resinas de baixa viscosidade, o presente estudo avaliou: Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF) e Filtek Z350XT Flow (Z3F-controle); e, para alta viscosidade: Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Fusion x-tra (ADM) e Filtek Z350 XT (Z3XT-controle). As resinas foram avaliadas em relação à tensão de polimerização (utilizando 12 e 24mm3 de resina adaptadas em um dispositivo adaptado a uma máquina de testes universal); contração volumétrica (utilizando 64mm3 de resina composta inserida em um molde de Teflon e escaneada em um micro-tomógrafo/CT), modulo de Young (através de um dispositivo de flexão em 3 pontos adaptado a uma máquina de testes universal), microdureza e profundidade de polimerização (utilizando microdureza Knoop). Todos os resultados foram avaliados em relação à homogeneidade utilizando o teste de Shapiro-Wilk. Para avaliação da tensão de polimerização, foi empregada a Análise de Variância (ANOVA) a 3 critérios. Para as analyses de contração volumétrica, Módulo de Young, microdureza e profundidade de polimerizaçao, ANOVA a um critério foi empregada. Todas as Análises de Variância foram seguidas pelo teste de Tukey e 5% foi adotado como nível de significância. A tensão de polimerização com 12mm3 demonstrou que SDR, TBF e XF geraram valores significantemente mais baixos após 300s, seguidas por outras resinas de alta viscosidade (ADM, FBF, XB e FBP/Z3XT). A resina convencional de baixa viscosidade (Z3F) gerou valores de tensão significantemente mais elevados para todos os tempos avaliados. Considerando o mesmo teste, com 24mm3, após 300s, SDR, FBP e ADM geraram valores estatisticamente inferiores, seguidas por TBF e XF. As resinas bulk fill de baixa visocidade geraram menor tensão de polimerização que a Z3F. Considerando o modulo de Young, resinas de baixa viscosidade (SDR, FBF, XB e Z3F) apresentaram valores significantemente inferiores, seguidas por ADM e TBF. As outras resinas de alta viscosidade (Z3XT, FBP e XF) apresentaram valores significantemente mais elevados. Para o teste de microdureza, todas as resinas de baixa viscosidade apresentaram valores inferiores (FBF apresentou o menor). Para as resinas de alta viscosidade, Z3XT apresentou os valores mais elevados, seguida por XF, FBP/TBF e ADM. Para profundidade de polimerização, resinas compostas convencionais apresentaram valores signifixantemente mais baixos quando comparadas com resinas bulk fill. Todas as resinas bulk fill apresentaram profundidade de polimerização adequada até pelo menos 4,5mm (microdureza 80% da leitura inicial/superfície). SDR e XB apresentaram os valores mais altos de profundidade de polimerização. Todas as resinas bulk fill de alta viscosidade geraram menor contração volumétrica que resinas compostas convencionais. Todas as resinas bulk fill de baixa viscosidade apresentaram contração volumétrica similar às resinas convencionais (Z3F e Z3XT). Resinas compostas bulk fill apresentaram características que possibilitam sua indicação para serem empregadas em grandes incrementos (contração volumétrica e tensão de polimerização similar ou inferiores às resinas convencionais, além de maior profundidade de polimerização). No entanto, as propriedades mecânicas variaram grandemente entre as resinas estudadas sendo importante uma avaliação individual de cada material previamente ao seu uso clínico.

Page generated in 0.0945 seconds