• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 984
  • 34
  • 34
  • 34
  • 34
  • 29
  • 29
  • 18
  • 14
  • 14
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 1004
  • 450
  • 288
  • 190
  • 188
  • 167
  • 158
  • 156
  • 150
  • 145
  • 127
  • 111
  • 106
  • 94
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Efeitos da radiação laser Arseneto de Gálio e Alumínio (780nm) no periodonto de sustentação de ratos diabéticos durante movimentação ortodôntica: analises radiográfica e histológica /

Sousa, Aretha Graziela Vilela de. January 2011 (has links)
Orientador: Mônica Fernandes Gomes / Banca: Luana Marotta Reis de Vasconcellos / Banca: Maria das Graças Vilela Goulart / Resumo: Diabetes Mellitus (DM) é considerado uma epidemia mundial, suas complicações implicam em alterações sistêmicas generalizadas. Concomitantemente cresce a acessibilidade e adesão da população brasileira, incluindo pacientes diabéticos, ao tratamento ortodôntico devido à modernização dos aparelhos ortodônticos e a conscientização das vantagens estéticas e funcionais deste tratamento. Este trabalho avaliou as alterações dos tecidos periodontais durante a movimentação ortodôntica com forças leves (20cN) em ratos diabéticos induzidos por aloxano, aplicando radiação laser diiodo de Arseneto de Galio e Alumínio (780nm) com densidade de energia de 20J/cm2. Foram utilizados 60 ratos divididos em 4 grupos: Controle, Laser, Diabético, Diabético-Laser, avaliados aos 7, 14 e 21 dias de movimentação ortodôntica. Realizou-se as análises radiográfica e imunohistoquímica da osteopontina para mensurar a movimentação ortodôntica. Diante dos resultados obtidos, pode-se concluir que a movimentação ortodôntica foi maior no grupo Diabetico do que nos demais grupos, entretanto a qualidade da microarquitetura periodontal foi indesejável; a laserterapia aplicada no grupo Diabético-Laser submetidos à movimentação ortodôntica, promoveu melhor preservação e integridade da microarquitetura dos tecidos periodontais quando comparado ao grupo Diabético, todavia foi semelhante aos resultados histológicos do grupo Controle; o número de osteócitos imunorreativos para a osteopontina foi maior no grupo Laser do que no grupo Diabético / Abstract: Diabetes Mellitus (DM) is considered a worldwide epidemic, its complications involve generalized systemic changes. At the same time increases the accessibility and adherence of the population, including diabetic patients, orthodontic treatment due to the modernization of orthodontic appliances and awareness of the aesthetic and functional advantages of this treatment. This study evaluated changes in periodontal tissues during orthodontic tooth movement with light forces (20cN) in alloxan-induced diabetic rats, using laser radiation diiodo of gallium arsenide and aluminum (780nm) with energy density of 20J/cm2. We used 60 mice divided into four groups: Control, Laser, Diabetic, Diabetic Laserassessed at 7, 14 and 21 days of orthodontic movement. We conducted the analysis of radiographic and osteopontin immunohistochemistry to measure the orthodontic movement. Considering the results obtained, it can be concluded that orthodontic movement was higher in the diabetic group than in the other groups, but the quality of periodontal microarchitecture was undesirable; laser therapy applied in the diabetic group, submitted to Laser Tooth movement, promoted better preservation and integrity of the microarchitecture of the periodontal tissues when compared to diabetic group, but was similar to the histological results of the control group, the number of osteocytes immunoreactive for osteopontin was higher in the laser group than in the diabetic group / Mestre
242

Influência da LLLT (GaAlAs) com diferentes energias na Movimentação ortodôntica em ratos / $$Binfluence Of The Lllt (Gaalas) With Diferent Energies On The Orthodontic Movement In Rats

Torri, Simone January 2013 (has links)
Made available in DSpace on 2013-10-11T13:36:08Z (GMT). No. of bitstreams: 1 000450849-Texto+Completo-0.pdf: 1707551 bytes, checksum: f049c5c7f4a25372abcca06fb06fbc9b (MD5) Previous issue date: 2013 / Introduction: Prolonged treatment times are one of the greatest challenges of orthodontic practice. Research has shown that laser therapy can be used as an adjunct to orthodontic movement, with effects on bone repair and analgesia. This study sought to assess the influence of low-level laser therapy (LLLT), using different energy settings, on orthodontic tooth movement in rats. Methods: Twenty-five male Wistar rats were randomly allocated across four different energy setting groups and one control group. A 10-g load was applied to the left maxillary first molar. During orthodontic movement, 830-nm laser radiation was administered to three spots at different energy settings depending on group allocation (12J, 15J, 18J, or 21J per site). Orthodontic movement was measured throughout the experiment and calcein dye was injected into the specimens for measurement of the area of neoformed bone. Results: There were no significant quantitative differences in orthodontic movement between the control and LLLT groups (P<0. 01). On histological examination, LLLT groups 12J, 15J, and 18J exhibited a significant increase in area of neoformed bone (P<0. 05).Conclusions: At the energy settings and protocols used in this study, LLLT does not appear to influence the rate of orthodontic movement, although different energy settings encourage bone neoformation. / Introdução: Um dos grandes desafios da ortodontia nos dias atuais é a diminuição do tempo de tratamento. Estudos tem demonstrado que o laser pode ser um auxiliar na movimentação ortodôntica, influenciando na reparação óssea e na analgesia. O objetivo desse trabalho foi analisar a influência da Low-Level Laser Therapy (LLLT) com diferentes energias na quantidade da movimentação ortodôntica em ratos.Métodos: Vinte e cinco ratos machos Wistar foram divididos aleatoriamente em cinco grupos de acordo com a energia de laser aplicada. Uma força de 10 gramas foi aplicada ao primeiro molar superior esquerdo. Nele foi aplicado laser, 830nm, com diferentes energias durante a movimentação ortodôntica (12J, 15J, 18J, 21J por ponto) em 3 pontos. A quantidade de movimentação dentária foi mensurada durante o experimento e calceína foi injetada nas amostras para marcar e possibilitar a mensuração da área do osso neoformado. Resultados: Com relação à quantidade de movimentação, não houve diferença estatisticamente significante entre o grupo controle e os grupos LLLT (P<0,01). Histologicamente, houve aumento significativo da área de osso neoformado nos grupos LLLT com energias de 12, 15 e 18J (P<0,05).Conclusões: Esses achados sugerem que a LLLT nas energias e protocolos aplicados nesse estudo não interferem na quantidade da movimentação dentária ortodôntica, apesar de estimular a neoformação óssea com a aplicação de determinadas energias.
243

Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam

Weissheimer, André January 2013 (has links)
Made available in DSpace on 2013-12-13T01:01:21Z (GMT). No. of bitstreams: 1 000452798-Texto+Completo-0.pdf: 11258762 bytes, checksum: 1779e23c337cdf8d461b246e5a82e0c5 (MD5) Previous issue date: 2013 / Introduction : this thesis aimed to evaluate the software accuracy for 3D analysis of craniofacial complex in cone beam computed tomography (CBCT). With this purpose, two studies were performed. The first study evaluated the precision and accuracy of 6 imaging software programs for measuring the upper airway volume in CBCT. The second study aimed to validate a fast method for 3D superimposition of CBCT. Methods : in study 1, the sample consisted of 33 growing patients and 1 oropharynx acrylic phantom (OAP), scanned with iCAT scanner. The known OAP volume was used as gold standard (GS). Semi-automatic segmentations of the patients´ oropharynx (OP) and OAP was performed using Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental and Ondemand3D software programs. In study 2, the sample consisted of CBCT scans of 18 patients. For 10 patients as a gold standard, the spatial position of the pretreatment CBCT volume was reoriented, saved as a reoriented volume, and then superimposed to the original image. For 8 patients, 4 non-growing and 4 growing patients, pre and post-treatment scans were superimposed. Superimposition accuracy was assessed by visual inspection and measured by using the CMF application and expressed via color maps. Results : in study 1, the OAP segmentations with Mimics, Dolphin3D, OsiriX and ITK-Snap showed less than 2% error in volume compared to the GS. Ondemand3D and InVivo Dental showed more than 5% error compared to the GS. In the OP segmentation, ITK-Snap, Mimics, OsiriX and Dolphin3D were statistically significantly different (P<. 05) from InVivo Dental. No statistical difference (P>. 05) was found between InVivo Dental and OnDemand3D. In study 2, Superimposition error of the spatial reorientation as measured by the color-coded surface distances was less than 0. 5mm. Superimposition error of pre and post treatment scans for both growing and non-growing patients at the cranial base were smaller than 0. 5 mm, which was considered acceptable and clinically insignificant. Conclusion : in study 1, all 6 imaging software programs were reliable but showed errors in the volume segmentation of OP. Mimics, Dolphin3D, ITK-Snap and OsiriX were similar and more accurate than InVivo Dental and Ondemand3D. In study 2, the voxel-based superimposition method evaluated was reproducible in different clinical conditions, time-efficient and potentially applicable for both research and clinical practice. / Introdução : o objetivo desta tese foi avaliar a acurácia de programas para análises 3D do complexo maxilofacial em tomografia computadorizada cone beam (TCCB). Com esse propósito, dois estudos foram realizados. O primeiro estudo avaliou a precisão e acurácia de 6 programas para avaliação do volume da via aérea superior em TCCB. O segundo estudo objetivou validar um método rápido de superposição 3D de TCCB.Método : no estudo 1, a amostra consistiu de 33 pacientes e 1 Phantom de acrílico da orofaringe (PAO), escaneados com o tomógrafo iCAT. O volume conhecido do PAO foi utilizado com “padrão ouro”. Segmentação semiautomática da orofaringe dos pacientes (OP) e do PAO foi realizada com os programas Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental e Ondemand3D. No estudo 2, a amostra consistiu de TCCB de 18 pacientes. Em 10 pacientes, como padrão de comparação, a TCCB pré-tratamento foi reorientada espacialmente, salva como TCCB reorientada, e então superposta na imagem original. Em 8 pacientes, sendo 4 sem crescimento e 4 em crescimento, foram superpostas as TCCB e pós-tratamento. A acurácia da superposição foi avaliada através de inspeção visual e mensurada através do programa CFM com mapas coloridos. Resultados : no estudo 1, as segmentações com o Mimics, Dolphin3D, OsiriX e ITK-Snap mostraram menos de 2% de erro no volume do PAO em comparação ao “padrão ouro”. O Ondemand3D e o InVivo Dental apresentaram mais de 5% de erro no volume do PAO em comparação ao “padrão ouro”. As segmentações da OP com o ITK-Snap, Mimics, OsiriX e Dolphin3D foram estatisticamente diferentes (P<. 05) em comparação ao InVivo Dental. Não houve diferença estatisticamente significante (P>. 05) entre os programas InVivo Dental e o OnDemand3D. No estudo 2, o erro da superposição das TCCB reorientadas, medidas através dos mapas coloridos foi menor que 0,5mm. O erro da superposição das TCCB pré-tratamento e pós-tratamento para pacientes com e sem crescimento, na região da base do crânio, foi menor que 0,5 mm e considerado aceitável e clinicamente insignificante. Conclusão : no estudo 1, todos os 6 programas foram precisos, mas apresentaram erros no volume da segmentação da OP. Mimics, Dolphin3D, ITK-Snap e OsiriX foram considerados similares e mais acurados em comparação ao InVivo Dental e Ondemand3D. No estudo 2, o método de superposição baseado em voxel avaliado foi reproduzível em diferentes condições clínicas, rápido e potencialmente aplicável para pesquisa e prática clínica.
244

Estudo comparativo das técnicas de fixação óssea em fraturas de côndilo mandibular através de análise por elementos finitos

Conci, Ricardo Augusto January 2014 (has links)
Made available in DSpace on 2014-04-11T02:01:23Z (GMT). No. of bitstreams: 1 000456864-Texto+Completo-0.pdf: 1845700 bytes, checksum: a5c9dbfafcce1c6f9782ab16bd534d34 (MD5) Previous issue date: 2014 / Mandibular condylar fractures are a theme of great importance within Oral and Maxillofacial Surgery due to their high incidence among facial fractures, and to numerous discussions regarding forms of treatment, surgical approaches, and the type of material used for fracture fixation. Treatment can be either surgical or nonsurgical, and depends upon certain situations and directions. When the choice is for surgical treatment proper fracture reduction and efficient internal fixation must be pursued to achieve good final results. Numerous plate configurations, whether or not isolated, with various shapes and sizes, are used for the surgical resolution of condylar fractures. In order to enhance the advantages and minimize the disadvantages of fixation techniques, the Neck Screw was developed, aiming at the necessary stability for proper fixation through a dynamic compression system that could increase the contact between the fractured stumps, and, at the same time, assist at the time of fracture reduction. The purpose of this study was to assess the fixation and stability of mandibular condylar fractures, and to compare three fixation techniques, in that the first configuration had a 2. 0 mm plate with 4 holes, and with 6-mm-long screws, the second configuration had two plates ─ one of 1. 5 mm and the other of 2mm ─-both with 4 holes, and with 6-mm-long screws, and the last had a Neck Screw. The results showed improved stability when using two plates, in regard to displacement of the fractures, deformation of the synthesis materials, and minimum and maximum tension values. The results with the Neck Screw were satisfactory, similar to those found when using a Mini-Plate, and it is thus an alternative for the reduction and fixation of condylar fractures, provided it is correctly prescribed, and follows an appropriate surgical sequence and technique. / As fraturas de côndilo mandibular representam um tema de grande importância dentro da Cirurgia e Traumatologia Bucomaxilofacial, pela grande incidência dentre as fraturas faciais, além das inúmeras discussões no que diz respeito às formas de tratamento, acessos cirúrgicos e o tipo de material que vai ser utilizado para fixação das fraturas. O tratamento divide-se em cirúrgico e não-cirúrgico, e depende de algumas situações e indicações. Quando o tratamento cirúrgico é a escolha, deve-se buscar uma adequada redução das fraturas, além de eficiente fixação interna para se obter um bom resultado final. Inúmeras configurações de placas, isoladas ou não, com formatos e tamanhos variados, são utilizadas para a resolução cirúrgica das fraturas condilares. Almejando aprimorar as vantagens e minimizar as desvantagens das técnicas de fixação, foi desenvolvido o parafuso Neck Screw, visando a estabilidade necessária para a correta fixação através de um sistema de compressão dinâmica, aumentando o contato entre os cotos fraturados, além de servir como aliado no momento da redução das fraturas. O presente trabalho tem como objetivo avaliar a fixação e a estabilidade das fraturas de côndilo mandibular e comparar três técnicas de fixação, sendo que a primeira configuração apresenta uma placa de 2. 0 mm, com 4 furos, com parafusos de 6 mm de comprimento, a segunda configuração apresenta duas placas, sendo uma de 1. 5 mm e outra de 2. 0 mm, ambas com 4 furos, com parafusos de 6 mm de comprimento e a última, apresenta o parafuso Neck Screw. Os resultados demonstram uma melhor estabilidade quando do uso de duas placas, no que diz respeito ao deslocamento das fraturas, deformação dos materiais de síntese e valores de tensões mínimas e máximas. Os resultados com o parafuso Neck Screw são satisfatórios, semelhantes aos encontrados quando da utilização de uma miniplaca, sendo, portanto, uma alternativa para redução e fixação das fraturas condilares, desde que corretamente indicado e com sequência e técnica cirúrgica adequadas.
245

Análise comparativa da movimentação dentária induzida entre dois critérios de mensuração : macroscópico e microscópico /

Moreira, José Roberto Alves. January 2009 (has links)
Resumo: Este estudo analisou a quantidade de deslocamento dentário por meio de mensurações macroscópicas e microscópicas, após a movimentação dentária induzida. Os dois Grupos Experimentais GI (forças contínuas) e GII (forças contínuas interrompidas) constituíram-se de 30 ratos, da linhagem Wistar, subdivididos de acordo com o período experimental de 8, 16 e 24 dias. Cada subgrupo foi composto por dez animais, assim como o Grupo Controle (GC), perfazendo um total de 70 animais. O aparelho destinado para se obter o deslocamento dentário foi o desenvolvido por Heller e Nanda. As molas de secção fechada foram instaladas no espaço entre os incisivos superiores e primeiro molar superior direito. Após ativações, de acordo com o tipo de força e tempo experimental, os animais foram mortos. Mediu-se a espessura do ligamento periodontal por meio de microscopia histomorfométrica quantitativa na raiz vestibular intermediária do primeiro molar superior direito do rato, na região distal (tração) e macroscópica, no espaço resultante entre os primeiro e segundo molares superiores direitos. A metodologia empregada permite concluir que as mensurações microscópicas são mais precisas e seguras para determinar o deslocamento na movimentação dentária induzida. / Abstract: This study analyzed the amount of displacement, by measuring macroscopic and microscopic, after induced tooth movement. Both groups GI (continuous forces) and GII (interrupted continuous force) comprised of 30 rats, Wistar, were subdivided according to the experimental period of 8, 16 and 24 days. Each group comprised of ten animals, as well as the control group (CG), totaling 70 animals. The appliance used to obtain the displacement, was developed by Heller and Nanda. The nickeltitanium (NiTi) coil springs were installed in the space between the upper incisors and the upper first right molar. After activation, according to the type of force and experimental time, animals were sacrificed. A quantitative histomorphometric microscopy was used to the measurement of the periodontal ligament thickness in the mesiobuccal root of the first upper right molar of the rat, in the distal and macroscopic region, at reached space between the first and second upper right molars. The microscopic measurements are accurate and reliable to determine the displacement in the induced tooth movement. / Orientador: Osmar Aparecido Cuoghi / Coorientador: Alberto Consolaro / Coorientador: Maria Fernanda Martins-Ortiz Consolaro / Banca: Marcos Rogério de Mendonça / Banca: Laurindo Zanco Furquim / Mestre
246

Alteração nos níveis de metaloproteinases da matriz e quimiocinas no fluido gengival durante o movimento dentário ortodôntico / Levels of the matrix metalloproteinases and chemokines in the gingival crevicular fluid of teeth under orthodontic forces

Jonas Capelli Júnior 29 June 2007 (has links)
O objetivo do presente estudo foi avaliar os níveis das metaloproteinases da matriz MMP-9, MMP-3 e MMP-13, e das quimiocinas MCP-1, MIP-1&#946; e RANTES, no fluido gengival de dentes sob força ortodôntica. Foram recrutados 14 pacientes (3 homens e 11 mulheres) que foram submetidos à movimentação ortodôntica dos caninos superiores. Amostras do fluido gengival foram coletadas com tiras de Periopaper em diferentes tempos. O volume do FG foi determinado com o uso do Periotron e os niveis das MMPs e das quimiocinas quantificados usando-se uma multianálise imunoenzimática com microesferas. Os resultados mostraram que existe um aumento significativo no volume do FG na área de pressão em quase todos os tempos analisados, quando comparados às áreas de tensão. Os níveis da MMP-9 foram muito superiores aos das MMP-13 e MMP-3. Na análise da evolução do tempo pode ser observada uma alteração significativa nos níveis da quantidade total de MMP-9, MMP-13 e MMP-3 e na concentração de MMP-13 e MMP-3 durante o período de movimentação dentária no lado de pressão. A elevação dos níveis de expressão destas MMPs 1 hora após a aplicação da força ortodôntica sugere que estas enzimas estejam envolvidas na remodelação periodontal induzida. As quimiocinas MCP-1, MIP-1&#946; e RANTES foram detectadas no sulco gengival em todos os diferentes intervalos de tempo analisados, nas áreas de tensão e de pressão. Porém, diversas amostras estavam abaixo do nível de detecção do ensaio e, os níveis dessas quimiocinas no fluido gengival não parecem ser alterados pelas forças ortodônticas. / The goal of the present study was to evaluate the levels of the matrix metalloproteinases MMP-9, MMP-3 and MMP-13 and of the chemokines MCP-1, MIP-1&#946; and RANTES in the gingival crevicular fluid of teeth under orthodontic forces. Fourteen subjects (3 males and 11 females) were enrolled and subjected to orthodontic tooth movement of their maxillary canines. Samples of gingival crevicular fluid were collected from both tension and pressure sides using Periopaper strips at different time points. The volume of GCF was determined using a Periotron and the levels of MMPs and chemokines quantified using a multiplex microbead immunoassay. The results demonstrated that the levels of MMP-9 were higher than the levels of MMP-13 and MMP-3. Statistically significant fluctuations during the orthodontic tooth movement could be detected for the total amount of MMP-9, MMP-13 and MMP-3 and for the concentration of MMP-13 and MMP-3 at the pressure side. The elevation in the levels of these MMPs, 1 hour after the application of the orthodontic force, suggests that these enzymes are involved in the induced periodontal remodeling. The chemokines MCP-1, MIP-1&#946; and RANTES were detected in the GCF in both tension and pressure sides at different time points. However, several samples were below the level of detection of the assay and the levels of theses mediators in GCF did not seem to be altered by the orthodontic forces.
247

Citotoxicidade e genotoxicidade de materiais ortodônticos

Westphalen, Graziela Henriques January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:02Z (GMT). No. of bitstreams: 2 000419165-0.pdf: 5355760 bytes, checksum: 19b3455362048d8c78c84e65df0785d8 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Biocompatibility evaluation of orthodontic materials is very important, since some constituent elements of these materials are related to citotoxic, genotoxic and carcinogenic effects. This study aimed to assess citotoxicity and genotoxicity of orthodontic materials. Citotoxicity of orthodontic materials (brackets, wires, resin composites, solder silver and elastomers) was tested by two survival exposure to Saccharomyces cerevisiae (S. Cerevisiae), through direct and indirect (chemical products liberated by these materials in artificial saliva) forms (Article 1). Assessment of genotoxicity was carried out in patient groups, using the following tests: Cytome buccal micronucleus assay for evaluating orthodontic fixed appliances and Hyrax (Article 2), Micronucleus tests for Hyrax and Haas appliances (Article 3). For Article 1, occurrence of S. Cerevisiae survival was compared in a semi-log curve between orthodontic materials and control groups. For articles 2 and 3, non parametric test was used (ES0. 05%) for comparison among patients and control groups. Silver solder was the only material that showed citotoxicity. All appliances tested did not present genotoxicity in studied patients. / A avaliação da biocompatibilidade dos materiais ortodônticos é de extrema importância, uma vez que elementos constituintes desses materiais estão relacionados a efeitos citotóxicos, genotóxicos e carcinogênicos Este estudo objetivou verificar a citotoxicidade e genotoxicidade de materiais ortodônticos. A citotoxicidade de materiais ortodônticos (bráquetes, fios, resinas compostas, soldas de prata e elásticos) foi testada por meio de duas exposições de sobrevivência ao Saccharomyces cerevisiae (S. Cerevisiae) de forma direta e indireta (produtos químicos liberados pelos materiais em saliva artificial) (Artigo 1). A avaliação da genotoxicidade foi realizada em grupos de pacientes, empregando-se os testes: Ensaio citoma bucal de micronúcleos para avaliação de aparelhos ortodônticos fixos e Hyrax (Artigo 2); Teste de micronúcleos para aparelhos expansores maxilares de Haas e Hyrax (Artigo 3). No artigo 1 foram realizadas comparações de ocorrência de sobrevivência de S. Cerevisiae em curvas semi-log entre os materiais ortodônticos e controle. Já nos artigos 2 e 3 foram empregados testes estatísticos não paramétricos diferentes (ES0,05) para comparações entre grupos de pacientes e controle. Foi observado que a solda de prata foi o único material que apresentou citotoxicidade. Todos os aparelhos testados não mostraram genotoxicidade nos grupos de pacientes estudados.
248

Retração de caninos superiores com dois tipos de elásticos em cadeia

Giollo, Luciano Dias January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000400719-0.pdf: 3832868 bytes, checksum: 7f7e5e2d5a4148bbc3e382e8c43c4bfc (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the speed of space closure in canine retraction submitted to two distinct types of elastomeric chains (Memory chain and Standard chain) and to determine: mean quantity of movement of upper canine retraction and the loss of anchorage involved. The sample consisted of 15 patients with Angle 1st division Class II malocclusion, with a mean age of 17, 5 years of 4 boys and 11 girls. All of them were submitted to first premolar extractions. Upper canine retraction was achieved with Standard elastomeric chains in the upper right quadrant and with Memory elastomeric chains in the upper left quadrant providing a starting force of 150 g. Canine retraction was assessed in a three week reactivation protocol, until canine retraction was completed or up to a maximum of 3 reactivations. At each recall, stone model casts were taken. The evaluation of the mean amount of space closure was accomplished in 4 different places (3 between canine-premolar and 1 between caninemolar) and anchorage loss measured between first permanent molar and medial point of third palatal rugae in stone model casts. Results showed a statistical difference towards Memory chain, at one measure point and between the first and second activations. Anchorage loss occurred in both specified retraction methods, however there was not significant difference between them. / O objetivo deste estudo foi avaliar o fechamento dos espaços na retração dos caninos permanentes superiores com dois tipos de elástico em cadeia distintos (elásticos em cadeia “Memory” e “Convencional”) determinando: a diferença média do movimento dentário e a perda de ancoragem dos primeiros molares permanentes superiores. A amostra constituiu-se de 15 pacientes portadores de maloclusão de Classe II divisão 1 de Angle, com média de idade de 17anos e 5 meses, sendo 4 do gênero masculino e 11 do feminino, e todos foram submetidos à extração de dois primeiros pré-molares superiores. A retração dos caninos superiores foi realizada com elástico em cadeia “Convencional”, na hemiarcada direita, e com elástico em cadeia tipo “Memory”, na esquerda, com força de 150 g. A distalização dos caninos foi avaliada a cada 3 semanas até esta ter sido completada ou num período máximo de 3 reavaliações. Em cada uma destas consultas, foi obtido modelo de gesso a partir de moldagens com alginato. A avaliação da quantidade média do fechamento dos espaços a cada 3 semanas foi feita em 4 locais diferentes (3 entre canino e pré-molar e 1 entre canino e molar) e a perda de ancoragem medida entre o primeiro molar permanente e o ponto mais medial da terceira ruga palatina nos modelos de gesso. Os resultados demonstraram maior movimentação com elásticos “Memory”, em uma das medidas de fechamento de espaços. Além disso, essa tendência limitou-se às três primeiras semanas de tratamento, perdendo a validade ao longo do período de retração de caninos superiores permanentes. Ocorreu perda de ancoragem para ambos os elásticos, no entanto, sem diferença estatística entre eles.
249

Efeitos imediatos da expansão rápida da maxila no sentido sagital, com os disjuntores tipo Haas e Hyrax, em tomografia computadorizada cone beam

Dias, Daniela Marchiori January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2 000424758-0.pdf: 7792361 bytes, checksum: 5c3a28a0cbc9f3ec5a2f68e92f3bbfe5 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated rapid maxillary expansion (RME) vertical and posteroanterior effects by means of cone- beam computed tomography (CBCT) in 33 patients, comparing tooth tissue–borne (Haas) and tooth-borne expanders (Hyrax). Haas group was composed of 18 subjects (13 girls and 5 boys; mean age, 10 ± 0. 11 years). Hyrax group consisted of 15 subjects (nine girls and six boys; mean age 10 ± 0. 11 years). All appliances were activated up to the full eight mm capacity of the expansion screw. The patients were subjected to a CBCT before (T1) and immediately after (T2) the active phase of expansion, the “growth factor” was not considered. The measures were evaluated by the analysis of variance of mixing model with repeated measures, where the age and sex were controlled by the statistical model. There was a forward movement of the maxilla in Haas group after RME, increasing SNA angle in 1 degree, while there wasn’t any change in the Hyrax group, there was a tendency of decrease the palatine plane and the oclusal plane to sella nasion (SN). Change in the angulation of the maxillary incisor was not significant, a tendency of uprighting was observed in both groups. Within the limits of this study, the results suggest that there weren’t significant changes in both groups in the sagittal plane immediately after rapid maxillary expansion. / Este estudo teve o objetivo de avaliar os efeitos ântero-posteriores e verticais da maxila decorrentes da expansão rápida em 33 pacientes com expansores dento-muco-suportado (tipo Haas) e dento-suportado (Hyrax) analisados pela tomografia computadorizada cone beam (TCCB). O grupo Haas foi composto por 18 indivíduos (13 meninas e 5 meninos) e o grupo Hyrax, 15 indivíduos (9 meninas e 6 meninos), ambos com idade esquelética média de 10 anos e 11 meses. Todos os expansores foram ativados até uma abertura de 8 mm do parafuso. Os resultados foram obtidos pela análise de TCCB antes (T1) e imediatamente após (T2) à fase ativa de expansão rápida da maxila (ERM), desconsiderando o fator crescimento. As medidas foram submetidas à análise de variância de modelo misto com medidas repetidas, sendo, as variáveis idade e sexo, controladas pelo modelo estatístico. Houve um deslocamento anterior da maxila no grupo Haas após a ERM, com aumento do ângulo SNA em 1 grau em média, não ocorrendo alteração no grupo Hyrax, e uma tendência de diminuição do plano palatino e do plano oclusal em relação à base do crânio em ambos os grupos. Não foram observadas mudanças significativas na posição dos incisivos superiores, havendo uma tendência de verticalização dos mesmos. Dentro dos limites deste estudo, não foram observadas alterações significativas no plano sagital para ambos os aparelhos imediatamente após o procedimento de expansão rápida da maxila.
250

Avaliação de hipersensibilidade a metais e toxicidade genética associadas ao uso de aparelhos ordotônticos fixos

Westphalen, Graziela Henriques January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:10Z (GMT). No. of bitstreams: 2 000386676-0.pdf: 3018083 bytes, checksum: d24f83f7441985d1dc1910ac8f3fa8e9 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the hypersensitivity to metals and the genetic toxicity associated with the use of fixed orthodontic appliances. Hypersensitivity reactions were verified through the patch test carried out by a dermatologist before and two months after the placement of orthodontic appliances in a group of patients. The genetic toxicity was evaluated by using the micronucleus test and the comet assay. The sample was constituted of cells of the oral epithelium of the patients. For micronucleus test, cells were sampled before and 30 days after the placement of orthodontic appliance. For comet assay, the sample was obtained before and 10 days after the placement of orthodontic appliance. For either the micronucleus test or the comet assay, slides were mounted and processed according to standard protocols and analyzed under light microscope. Statistical analysis was performed by non-parametric tests (Fisher’s Exact Test, McNemar and Wilcoxon) and descriptive analysis. Regarding hypersensitivity, no differences were observed between the reactions before and after placement of the orthodontic appliances, which indicates that they did not sensitize patients. The comet assay showed low DNA damage level either before or after orthodontic appliance placement. Conversely, micronucleus test revealed a significant increase of permanent chromosomal damages in the period of 30 day after the placement of orthodontic appliance. Thus, more studies are still needed to understand the genetic toxicity potential of orthodontic devices, and long term studies of follow-up of the orthodontic patients are suggested. / O objetivo desse estudo foi avaliar a hipersensibilidade a metais e a toxicidade genética associadas ao uso de aparelhos ortodônticos fixos. As reações de hipersensibilidade foram verificadas por análise dermatológica utilizando o teste de contato, antes e dois meses após a montagem do aparelho ortodôntico em um grupo de pacientes. A toxicidade genética foi avaliada pelo teste de micronúcleos e pelo ensaio cometa, a partir de células da mucosa bucal dos pacientes. Para o teste de micronúcleos, as células foram coletadas antes e 30 dias após a montagem do aparelho ortodôntico. Para o ensaio cometa, a amostra foi obtida antes e 10 dias após o início do tratamento ortodôntico. Para os dois testes foram preparadas lâminas, cuja leitura foi realizada em microscópio óptico. Na análise estatística empregaram-se testes não paramétricos (Teste Exato de Fisher, McNemar, Wilcoxon) e análise descritiva. Em relação às reações de hipersensibilidade, não foi observada diferença antes e após a montagem do aparelho ortodôntico, o que indica que os pacientes não foram sensibilizados pelo aparelho. O ensaio cometa mostrou baixos níveis de dano no DNA nas células avaliadas, tanto antes quanto após a montagem do aparelho. No entanto, no teste de micronúcleos foi observado um aumento significativo de danos cromossômicos permanentes no período de trinta dias após a montagem do aparelho ortodôntico. Dessa forma, pesquisas adicionais são necessárias a fim de avaliar o potencial genotóxico dos aparelhos ortodônticos fixos, em associação a estudos de longo prazo de acompanhamento dos pacientes.

Page generated in 0.0694 seconds