• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 14
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

骨形成因子 (Bone Morphogenetic Protein-BMP) とフィブリン糊混合剤の骨・軟骨誘導能に関する研究

HATTORI, TOSHIKADO, 服部, 寿門 09 1900 (has links)
名古屋大学博士学位論文 学位の種類 : 博士(医学)(論文) 学位授与年月日:平成3年2月1日 服部寿門氏の博士論文として提出された
12

Evaluation in vitro et in vivo d’un polymère biorésorbable à la Gentamycine dans le traitement expérimental d’infections ostéo-articulaires / In vitro and in vivo evaluation of a gentamicin-loaded bioresorbable polymer in the experimental treatment of osteoarticular infections

Marcheix, Pierre-Sylvain 21 December 2016 (has links)
Le traitement d'une infection ostéo-articulaire nécessite une prise en charge longue, obligeant à des chirurgies itératives et à un traitement antibiotique systémique prolongé. À ce jour, le polyméthacrylate de méthyle est le vecteur d’antibiotique local le plus fréquemment utilisé chez l’homme pour traiter une infection ostéo-articulaire. Cependant les PMMA sont non résorbables et obligent à multiplier les interventions chirurgicales afin d’aboutir au traitement définitif de l’infection ostéo-articulaire. Le PMMA ne permet pas une libération complète de l’antibiotique avec de surcroît des doses inférieures à la CMI du germe en cause, pouvant faciliter l’émergence de bactéries résistantes. L'objectif de notre travail était d’obtenir une libération locale efficace et prolongée d’antibiotique grâce à un polymère entièrement résorbable. Le cahier des charges établi pour l’élaboration de ce polymère était le suivant : système matriciel offrant une libération de gentamicine à une dose de 1 à 2 mg/jour/g de mélange sur une période de plus de 10 jours. De plus, le polymère devait être bio-résorbable, c’est-à-dire qu’il devait pouvoir être dégradé jusqu'à obtenir des fragments pouvant être éliminés naturellement par l'organisme. Afin de répondre à ces exigences, il a été créé le PLA50P, Poly(D,L-acide lactique) de haut poids moléculaire. Afin d’obtenir le mélange gentamycine-PLA, une technique de compression des poudres des deux composants a été mise en œuvre. Ce polymère pouvait être stérilisé par -irradiation, sans influence sur les caractéristiques de relargage du polymère.La cinétique in vitro de la gentamicine relarguée par le PLA50GS montrait un pic maximum de gentamicine libérée obtenu à 12 jours et une stabilisation ensuite jusqu’à 63 jours de la quantité relarguée. La quantité cumulée de gentamicine relarguée à 3 semaines in vitro est de 54 % de la quantité contenue initialement dans PLA50GS. In vivo, nous observions une libération in situ de 5,1 µg/mL de gentamicine à J3, de 1,9 µg/mL de gentamicine à J7 et de 0 µg/mL à 5 semaines avec disparition de PLA50GS à l’examen macroscopique. Nous avons ainsi pu mettre en évidence, in vitro et in vivo, un relargage de la gentamicine à des doses supérieures à la CMI du germe et ce pendant plus de trois semaines.Afin de confirmer ces observations, nous avons ensuite mis au point un modèle d’infection périostée chez le rat. Pour ce faire nous avons utilisé des rats âgés de 10 à 12 semaines avec une injection au contact de l’os et au 1/3 moyen de la patte arrière de deux fois 100 ml de SAMS d’origine animale. L’utilisation du PLA50GS a montré sa supériorité par rapport à une administration parentérale d’une dose équivalente de Gentamicine avec une négativation du contage bactériologique chez tous les rats traités par le polymère chargé à la Gentamicine. Nous avons ensuite voulu traiter une infection articulaire grâce à notre polymère. Nous avons donc créé un modèle animal utilisant un lapin femelle de 4 kg avec une injection de 1 ml d’une solution à 103 CFU/ml de staphylococcus méthi-sensible d’origine léporidée. Le PLA50GS nous a permis de réduire très significativement la charge bactérienne intra-articulaire (baisse de 3 à 4 log10 soit 1000 à 10000 fois moins de bactéries) alors que le traitement antibiotique par voie générale dit de référence ne nous a pas permis de réduire l’infection intra-articulaire de façon significative par rapport au groupe non traité. Le PLA50GS nous a ainsi permis de réduire l’infection de 3 log10 par rapport aux autres groupes avec 2 lapins sur 6 guéris de leur infection.Le PLA50GS présente, ainsi, les caractéristiques suivantes : (i) stabilité de la Gentamicine au sein du polymère, (ii) polymère sous forme de poudre stable, (iii) relargage prolongé de la Gentamicine pendant plusieurs semaines, (iv) effet « burst » présent mais limité, (v) très bonne biotolérance, et (vi) efficacité supérieure aux traitements antimicrobiens classiques. / The treatment of soft-tissue infections, osteomyelitis, and acute or chronic septic arthritis is a lengthy process that involves repeated surgical procedures and the systemic administration of antibiotics for at least 6 weeks to 3 months. Poor diffusion of antibiotics into bones and joints requires high doses given parenterally for long periods. At present, the antibiotic vector most widely used in humans with bone or joint infections is polymethylmethacrylate. Because PMMA is not bioabsorbable, multiple surgical procedures are required to eradicate infection. Furthermore, PMMA does not release its full antibiotic load over time and may yield local antibiotic concentrations lower than the minimal inhibitory concentration of the causative organism, thereby promoting the emergence of resistant strains. The objective of our work was to develop a fully bioabsorbable polymer capable of ensuring the prolonged and efficient release of its antibiotic load, thus improving the management of bone and joint infections. The specifications for the polymer included the release by the matrix system of 1-2 mg of gentamicin per day and per gram of mixture over more than 10 days. Other specifications were appropriate physical characteristics, a drug release rate sufficient to ensure optimal treatment safety, and ease of implantation. The polymer was also to be bioabsorbable, i.e., subject to degradation into fragments capable of being eliminated naturally by the body. High-molecular weight PLA50P, Poly(D,L-lactic acid) was created and found to meet these specifications. Use of this polymer as large particles (0.5 to 1 mm) limited the initial burst phenomenon. A gentamicin-PLA50P mixture was obtained by compression of the two components prepared in powder form. The antibiotic load was set at 20% to limit the initial burst. The polymer can be sterilized by gamma irradiation, which has no effect on drug release characteristics.In vitro kinetic studies of gentamicin release by the polymer showed a peak on day 12 followed by a plateau that lasted until day 63. After 3 weeks, the cumulative amount of gentamicin released in vitro was 54% of the total amount loaded onto the polymer. In vivo gentamicin concentrations measured in situ were 5.1 µg/mL on day 3, 1.9 µg/mL on day 7, and 0 µg/mL on day 35, when the polymer was no longer visible to the naked eye. Thus, both in vivo and in vitro, gentamicin was released in concentrations greater than the MIC of the microorganism, for longer than 3 weeks.To test the gentamicin-loaded polymer, we created a rat model of periosteal infection. Rats aged 10-12 weeks received two 100 mL injections of methicillin-susceptible Staphylococcus aureus collected from animals, into the middle third of the hind leg, in contact with the bone. Treatment with gentamicin-loaded PLA50P proved superior over parenteral administration of an equivalent gentamicin dose, consistently reverting the bacteriological cultures to negative. We then created a rabbit model of septic arthritis. A doe weighing 4 kg received an add intraarticular injection of 1 mL of a solution containing 103 cfu/mL of a methicillin-sensitive S. aureus strain collected from another rabbit. Gentamicin-loaded PLA50P treatment induced a highly significant drop in the intraarticular bacterial load (by 3-4 log10), whereas standard systemic gentamicin therapy failed to significantly diminish bacterial counts comparatively to the untreated controls. Thus, gentamicin-loaded PLA50P diminished the bacterial load by 3 log10 comparatively to the other groups and allowed eradication of the infection in 2 of the 6 rabbits.In sum, gentamicin-loaded PLA50P (i) ensures the stability of the antibiotic; (ii) is available as a stable powder; (iii) ensures the prolonged release of gentamicin over several weeks; (iv) produces a limited burst effect; (v) exhibits very good biotolerance; (vi) and is more effective than standard antimicrobial therapy.
13

Micro-structuration de la surface des matériaux avec ligands bioactifs pour mimer la matrice extra-cellulaire osseuse / Micro-engineered substrates as bone extracellular matrix mimics

Bilem, Ibrahim 31 August 2016 (has links)
Actuellement, il est largement reconnu que la décision des cellules souches de maintenir leur caractère souche ou se différencier vers une lignée spécialisée dépend particulièrement de la nature de leur microenvironnement, appelé niche cellulaire. Une des composantes essentielles de cette niche cellulaire est la matrice extracellulaire (MEC), qui au-delà de sa fonction de support cellulaire, détermine le devenir des cellules souches en fonction de sa composition biochimique, sa structure et sa localisation. D’un point de vue rationnel, un biomatériau destiné à remplacer la fonction d’un tissu endommagé doit non seulement jouer le rôle d’échafaudage cellulaire mais également mimer les propriétés de la MEC dans son ensemble. Malheureusement, il est extrêmement difficile de concevoir des biomatériaux mimétiques de la MEC naturelle tenant compte de sa complexité structurelle et fonctionnelle. Pour pallier à cette problématique, il semble nécessaire d’effectuer un travail en amont de déconstruction/reconstruction de la complexité de la MEC en étudiant l’effet individuel puis combiné de ses propriétés sur la différenciation des cellules souches. Ce projet de doctorat rentre dans le cadre de ce travail et vise à déterminer le rôle spécifique ou concomitant de différentes propriétés inhérentes à la MEC sur la différenciation ostéoblastique des cellules souches mésenchymateuses humaines (hCSMs). En effet, nous avons évalué l’effet de la composition biochimique de la MEC et la distribution spatiale des ligands sur la différenciation des hCSMs, en fonctionnalisant la surface d’un matériau modèle avec les peptides RGD et/ou BMP-2, distribués d’une manière aléatoire ou structurée. / Actually, it is well-established that maintaining the stemness character of stem cells or eliciting their lineage-specific differentiation is closely related to the nature of their microenvironment, known as stem cell niche. The extracellular matrix (ECM), a key component of stem cell niche, not only provides a support function for stem cells but also dictates their fate decision. From a rational point of view, a biomaterial intended to replace a damaged tissue should mimic the natural ECM in all its aspects, including its biochemistry, 3D structure, topography, porosity, rigidity…. etc. Unfortunately, the design of biomaterials that fully mimic the natural ECM is still a big challenge, due to its high structural and functional complexity. Towards the development of finely-tuned biomaterials, it seems important to start by deconstructing and then reconstructing the complexity of the ECM. In this context, the thesis project, herein, seeks to evaluate both the individual and the synergistic effect of different properties inherent to the natural ECM on human mesenchymal stem cells (hMSCs) osteogenic differentiation. Indeed, we investigated whether the biochemical composition of the ECM and the spatial distribution of its components modulate hMSCs osteogenesis. This was achieved by creating different artificial ECMs, in vitro, containing RGD and/or BMP-2 mimetic peptides, distributed randomly or as specific micropatterns on the surface of a model material.
14

Bad to the Bone: The Effects of Therapeutic Glucocorticoids on Osteoblasts and Osteocytes

Gado, Manuel, Baschant, Ulrike, Hofbauer, Lorenz C., Henneicke, Holger 04 April 2024 (has links)
Despite the continued development of specialized immunosuppressive therapies in the form of monoclonal antibodies, glucocorticoids remain a mainstay in the treatment of rheumatological and auto-inflammatory disorders. Therapeutic glucocorticoids are unmatched in the breadth of their immunosuppressive properties and deliver their anti-inflammatory effects at unparalleled speed. However, long-term exposure to therapeutic doses of glucocorticoids decreases bone mass and increases the risk of fractures – particularly in the spine – thus limiting their clinical use. Due to the abundant expression of glucocorticoid receptors across all skeletal cell populations and their respective progenitors, therapeutic glucocorticoids affect skeletal quality through a plethora of cellular targets and molecular mechanisms. However, recent evidence from rodent studies, supported by clinical data, highlights the considerable role of cells of the osteoblast lineage in the pathogenesis of glucocorticoid-induced osteoporosis: it is now appreciated that cells of the osteoblast lineage are key targets of therapeutic glucocorticoids and have an outsized role in mediating their undesirable skeletal effects. As part of this article, we review the molecular mechanisms underpinning the detrimental effects of supraphysiological levels of glucocorticoids on cells of the osteoblast lineage including osteocytes and highlight the clinical implications of recent discoveries in the field.

Page generated in 0.0472 seconds