• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 53
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 194
  • 172
  • 100
  • 56
  • 54
  • 45
  • 42
  • 41
  • 41
  • 41
  • 40
  • 38
  • 34
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeito do ruído contralateral na amplitude das emissões otoacústicas evocadas por clique em crianças com audição normal e crianças com neuropatia Auditiva/Dessincronia Auditiva / The effect of the contralateral stimulation of the noise in the amplitude of the click-evoked otoacoustic emissions in children having normal hearing and children with Auditory Neuropathy/ Auditory Dsy-synchrony

Melo, Ana Dolores Passarelli de 20 April 2007 (has links)
A utilização das emissões otoacústicas (EOs) têm contribuído na avaliação do sistema auditivo eferente por meio do estudo do efeito da estimulação acústica simultânea à pesquisa das EOs, descrito na literatura como supressão das EOs. Este trabalho teve por objetivo comparar o efeito da estimulação contralateral do ruído na amplitude das emissões otoacústicas evocadas por clique (EOE-c), em crianças que apresentam audição normal e em crianças com Neuropatia Auditiva/Dessincronia Auditiva. A casuística foi constituída de 16 crianças com audição normal e 11 crianças com o diagnóstico audiológico de Neuropatia Auditiva/Dessincronia Auditiva. As EOE-c foram pesquisadas, utilizando-se o clique linear na intensidade de 60 dB NPS e, para a estimulação contralateral do ruído, foi utilizado o ruído branco na intensidade de 65 dB NPS, com monitoramento do nível de pressão sonora, gerado no conduto auditivo externo, por meio do microfone sonda. Os resultados demonstraram que, nas crianças com audição normal, além da redução da amplitude das EOE-c, foi observada supressão das EOE-c, ou seja, a ausência do registro das EOE-c com a estimulação contralateral do ruído. Nas crianças com Neuropatia Auditiva/Dessincronia Auditiva, foi observado que a estimulação contralateral do ruído não provocou mudanças significativas na amplitude das EOE-c. Este trabalho permitiu concluir que a amplitude das EOE-c do grupo de crianças com audição normal se comportou de maneira estatisticamente diferente do grupo de crianças com Neuropatia Auditiva/Dessincronia Auditiva na presença da estimulação contralateral do ruído, e que a média da redução da amplitude das EOE-c frente à estimulação contralateral do ruído nas crianças com audição normal é estatisticamente maior que a redução da amplitude das EOEc nas crianças com Neuropatia Auditiva/Dessincronia Auditiva. / The use of otoacoustic emissions (EOs) has contributed to the evaluation of the efferent auditory system through the effect of the acoustic stimulation simultaneous to the EOs, described in the literature as EOs suppression. This study had the objective of comparing the effect of the contralateral stimulation of the noise in the amplitude of the click-evoked otoacoustic emissions (EOE-c), in children having normal hearing and in children with Auditory Neuropathy/ Auditory Dsy-synchrony. The casuistry was constituted by 16 children having normal hearing and 11 children diagnosed audiologically as having Auditory Neuropathy/ Auditory Dsy-synchrony. The EOE-c were scrutinized by using the linear click in the intensity of 60 dB SPL, and to the contralateral noise stimulation, the white noise was employed in the intensity of 65 dB SPL, with the monitoring of the level of sound pressure generated in the external auditory conduit, by using the microphone probe. The results have shown that in children with normal hearing, besides the reduction of amplitude of the EOE-c, it was noticed their suppression, that is, the absence of the record of the EOE-c with the contralateral noise stimulation. It was observed that the contralateral noise stimulation havent provoked significative change in the amplitude of the EOE-c in children with Auditory Neuropathy/ Auditory Dsy-synchrony. This study allowed us to conclude that the amplitude of EOE-c in children with normal hearing presented a different statistical result in the group of children with Auditory Neuropathy/ Auditory Dsy-synchrony in the presence of the contralateral noise stimulation and the average of the amplitude reduction of the EOE-c in the face of children with normal hearing is statistically higher than the amplitude reduction of the EOE-c in the children with Auditory Neuropathy/Auditory Dsy-synchrony.
62

Função da orelha média e das curvas de crescimento nas respostas das emissões otoacústicas / Middle-ear and growth functions on the responses of the otoacoustic emissions

Campos, Ualace de Paula 28 June 2011 (has links)
INTRODUÇÃO: Dentre as medidas da função coclear, a curva de crescimento das Emissões Otoacústicas por produto de distorção (CCEOA PD) permite o registro da amplitude da emissão em função do crescimento sistemático nos níveis de tons primários. A CCEOA PD fornece parâmetros específicos sobre o limiar e o comportamento não-linear das EOA PD, porém a variabilidade das respostas inter e intrasujeitos reduz a confiabilidade dessa medida na avaliação da robustez das respostas cocleares e a relação dessa robustez com os limiares auditivos. OBJETIVOS: Esta pesquisa estudou as interações entre as medidas timpanométricas da orelha média e as medidas de função coclear em adultos jovens sem queixas auditivas, de acordo com as variáveis: antecedentes de alterações de orelha média, sexo e orelha direita / esquerda. MÉTODOS: Participaram 69 indivíduos com audição normal e idades entre 18 e 34 anos, sendo 21 homens e 48 mulheres. A caracterização das condições de orelha média foi obtida pela anamnese, com a informação dos antecedentes de alterações de orelha média e pela timpanometria com sondas de admitância de 226 e 1000 Hz. A audiometria foi realizada com resolução de 01 dB NA, o que possibilitou comparações mais refinadas entre o limiar psicoacústico da audiometria tonal, a amplitude do DP-Gram e os limiares das CCEOA PD. Além dessas variáveis, a interferência dos fatores sexo e orelha foram testadas em todas as análises. RESULTADOS/DISCUSSÃO: Os resultados apontaram que as curvas de crescimento sofreram influência significativa das variáveis sexo, antecedentes de alterações de orelha média e orelha direita \\ esquerda, porém, apenas a interferência dos antecedentes foi constante e causou um padrão de modificação, ou seja, o grupo com antecedentes apresentou respostas aquém das respostas do grupo sem antecedentes. Os limiares audiométricos também apresentaram alta correlação com as amplitudes das EOA PD e com os limiares das CCEOA PD, quando identificadas as variáveis que interferiram nos resultados. Considerando que o ruído de fundo foi controlado nessa pesquisa, durante a avaliação das EOA PD e CCEOA PD, os resultados confirmaram a importância da consideração dessas variáveis na composição de grupos com audição normal em pesquisas com medidas de emissões otoacústicas. Ainda sobre os resultados, foi possível, por meio da medida da curva de crescimento (slope e limiar), demonstrar que o padrão de crescimento das CCEOA PD é diferente nos casos de modificação nas condições de orelha média e isso foi verificado tanto pelos antecedentes de alterações de orelha média quanto pelas medidas timpanométricas com sonda de admitância de 1000 Hz. CONCLUSÃO: O limiar das CCEOA - PD estudado nessa pesquisa apresentou correlação positiva com valores audiométricos e negativa com o DP-Gram. A inclinação da curva de crescimento (slope) também apresentou alta correlação com os antecedentes de alterações de orelha média, apontando o potencial valor desta medida no estudo da função coclear saudável e alterada e, conseqüentemente, sua possível utilização nas medidas prescritivas de amplificação / INTRODUCTION: The Distortion Product Otoacoustic Emissions Input/Output function (DPOAE I/O function) is a subdivision of DPOAE, where the response amplitude is recorded such as a systematic growth function in the primary tones. The DPOAE I/O function provides specific parameters about the DPOAEs threshold and non-linearity. However, the response variability reduces the measure reliability to evaluate the cochlear robustness and the relationship between robustness and hearing thresholds. OBJECTIVE: This research studied the interaction between the tympanometric measures and cochlear functions measures in young adults without hearing complaints, considering the variables: middle-ear alteration antecedents, gender and right / left ear. METHODS: 69 normal hearing subjects, aged from 18 to 34 years participated of the study. From the total, 21 were men and 48 women. To reach the proposed objectives, the middle ear conditions were assessed by anamneses and 226 and 1000 Hz admittance probe-tone tympanometry. The audiometric thresholds were searched with 01 dBHL resolution to enable refined comparisons among pure-tone audiometry and DP-Gram amplitude and DPOAE I/O function thresholds. The gender and ear interference were also evaluated in all analyses. RESULTS/DISCUSSION: The results showed that the variables gender, antecedents and ear affected the I/O functions responses, but only the middle-ear alterations antecedents presented a constant modification pattern. In other words, the group with antecedents presented mainly reduced responses in comparison with no antecedents group. The audiometric thresholds also presented high correlation with DPOAE amplitudes and DPOAE I/O functions thresholds, after the detection of the variables affecting the results. As the background noise was controlled during this study, the results confirmed the importance of monitoring these variables in the normal hearing group compositions to perform researches with DPOAE. Regarding the DPOAE I/O functions (slope and threshold), the growth pattern was modified according the middle ear conditions, verified by the antecedents of middle ear alterations and 1000 Hz admittance probe-tone tympanometry. CONCLUSION: The DPOAE I/O function threshold studied presented positive correlation with audiometric thresholds and negative correlation with DP-Gram. The DPOAE I/O functions slope also showed high correlation with antecedents of middle ear alterations, denoting the potential value of this measure in the study of the healthy and damaged cochlear function and, hence, it possible application in amplification prescriptive measures
63

Função coclear e resolução temporal em indivíduos com zumbido / Cochlear function and temporal resolution in tinnitus

Sanches, Seisse Gabriela Gandolfi 02 March 2009 (has links)
Introdução: O zumbido pode estar, em muitos casos, relacionado a alguma causa coclear, agindo como o início de processos dentro do sistema nervoso, resultando na sua percepção. Estudos recentes apontam que alterações cocleares podem prejudicar o mecanismo de compressão coclear, o que, por sua vez, pode comprometer a habilidade de resolução temporal envolvida no processamento auditivo. Quando a função coclear está preservada, o desempenho nas tarefas de processamento auditivo será mais eficiente. Para avaliar o grau do comprometimento coclear, informações sobre o limiar de emissões otoacústicas e o efeito de compressão coclear, ambos estimados pelas curvas de crescimento de emissões otoacústicas, aliados às medidas dos limiares auditivos para altas freqüências entre 9 e 20 kHz, contribuem na avaliação da função coclear em indivíduos que apresentem limiares auditivos dentro da normalidade na audiometria convencional. O estudo desta condição periférica e a sua influência sobre a habilidade auditiva de resolução temporal podem contribuir para a compreensão da percepção auditiva em indivíduos com zumbido e audição normal. Objetivo: verificar as medidas das Emissões otoacústicas por produto de distorção (EOAPD), dos limiares auditivos para altas freqüências (acima de 8 kHz), e a habilidade auditiva de resolução temporal, avaliada por meio do teste GIN (Gaps-in-noise), em adultos que apresentam limiares auditivos dentro da normalidade, com e sem queixa de zumbido. Método: Participaram do estudo um total de 48 adultos, com limiares auditivos entre 0,25 e 8 kHz dentro da normalidade, compondo 2 grupos: Grupo Controle formado por 28 sujeitos (55 orelhas), sem queixa de zumbido, com idades entre 22 e 40 anos (média 28,8), sendo 10 homens e 18 mulheres; e o Grupo Pesquisa formado por 20 indivíduos (40 orelhas) que apresentavam queixa de zumbido, com idades entre 21 e 56 anos (média 33,8 anos), sendo 3 homens e 17 mulheres. Os sujeitos foram submetidos a: audiometria tonal nas freqüências de 8 a 20 kHz; medidas de EOAPD com obtenção do DP-grama e da curva de crescimento; Teste GIN. Resultados: Para as curvas de crescimento das EOAPD, houve diferença significante entre os grupos, sendo que o grupo com zumbido apresentou limiares mais elevados em 2002 Hz. As medidas do DP-grama apresentaram amplitude de respostas menores para o grupo de indivíduos com zumbido em relação ao grupo Controle, sendo que esta diferença foi significante em 6006 Hz. Os limiares tonais para freqüências entre 9 kHz e 20 kHz foram significativamente mais elevados para os indivíduos com zumbido. Os resultados do teste GIN mostraram menor porcentagem de acertos e limiares de identificação do intervalo de silêncio mais longos para os indivíduos com zumbido em relação ao grupo Controle. Conclusão: Os indivíduos com zumbido, mesmo apresentando limiares auditivos dentro da normalidade, apresentaram alterações nas EOAPD e na audiometria em freqüências acima de 8 kHz, sugerindo alteração coclear. O teste GIN identificou dificuldade na habilidade auditiva de resolução temporal nos indivíduos com zumbido. / Introduction: In many cases tinnitus may be related to some cochlear cause, acting as the beginning of processes within the nervous system which will result in its perception. Recent studies point out that cochlear alterations may damage the cochlear compression mechanism, which may hinder the temporal processing skill that is involved in the auditory processing. When the cochlear function is preserved, the performance in auditory processing tasks is more efficient. Information on otoacoustic emissions threshold and on cochlear compression effect, both estimated by the DP-growth of otoacoustic emissions, associated to extended high-frequency hearing thresholds, contribute for the assessment of the cochlear function in individuals with normal hearing thresholds in the conventional audiometry. The investigation of this peripheral condition and its influence upon the auditory skill of temporal resolution may contribute for the understanding of hearing perception in individuals with tinnitus and with normal hearing. Aim: to investigate measures of distortion product otoacoustic emission (DPOAE), extended high-frequency hearing thresholds, and the temporal resolution using the GIN (Gaps-in-noise) test in adults with normal hearing thresholds with and without tinnitus complaint. Method: 48 adults with normal hearing thresholds at frequencies from 0,25 to 8 kHz took part in this study, divided into two groups: Control Group composed by 28 subjects (55 ears) without tinnitus complaint, ranging in age from 22 to 40 years (mean age= 28,8), 10 men and 18 women; and Study Group composed by 20 individuals (40 ears) with tinnitus complaint, ranging in age from 21 to 56 years (mean age = 33,8), 3 men and 17 women. Subjects underwent extended high-frequency audiometry; DPOAE evaluation obtaining the DP-gram and the DP-growth; and the GIN test. Results: There was a statistical significant difference between the groups for the DP-growth, the tinnitus group presented higher thresholds at 2002 Hz. DP-gram measures presented lower amplitude responses in the tinnitus group when compared to the Control group; this difference was statistically significant at 6006 Hz. Hearing thresholds for frequencies between 9 kHz and 20 kHz were statistically higher in individuals with tinnitus. Results of the GIN test showed lower percentage of correct responses and longer time interval for identification of gaps in noise for individuals with tinnitus than for individuals from the Control group. Conclusion: Individuals with tinnitus, even presenting normal hearing thresholds, present altered DPOAE and extended high-frequency audiometry suggesting cochlear impairment. The GIN test identified difficulty in the auditory skill of temporal resolution in individuals with tinnitus.
64

The Effect of Noise on DPOAEs and Pure-tone Thresholds

West, A. D., Burks, Christopher A., Foren, D., Fagelson, Marc A. 01 November 2002 (has links)
No description available.
65

Suppression in Otoacoustic Emissions Evoked by Closely-spaced Two-tone Burst Stimuli

Smurzynski, Jacek, Jedrzejczak, W., Blinowska, Krzysztof 01 January 2008 (has links)
No description available.
66

Spontaneous and Distortion Product Otoacoustic Emissions and Extended High-frequency Hearing Sensitivity

Fleenor, L., Smurzynski, Jacek 10 September 2006 (has links)
No description available.
67

New Clinical Applications of Otoacoustic Emissions

Smurzynski, Jacek 16 September 2016 (has links)
No description available.
68

Active Cochlear Processes and their Influence on the Generation of Otocoustic Emissions

Smurzynski, Jacek 10 February 2011 (has links)
No description available.
69

Performance of Otoacoustic Emission Tests when Used to Predict Auditory Status

Smurzynski, Jacek 22 October 2004 (has links)
No description available.
70

Time-course of Contralateral Suppression of Spontaneous Otoacoustic Emissions

Smurzynski, Jacek 01 January 2006 (has links)
No description available.

Page generated in 0.0496 seconds