• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Double Network Formation During Aging of a Natural Rubber Vulcanizate

Ohlemacher, Crittenden John January 2005 (has links)
No description available.
2

Estudo experimetal comparativo da histotoxicidade entre o copolímero de poli (ácido láctico-co-glicólico) e a blenda poli (ácido láctico-co-glicólico) / poli (isopreno)

Kim, Jung Ho January 2012 (has links)
Introdução: A aplicação clínica de biomateriais está se expandindo para diversas especialidades médicas. Dentre os diversos tipos de biomateriais, os classificados como temporários merecem atenção especial, pois são assimilados pelo organismo após exercerem sua função, evitando, assim, procedimento cirúrgico para sua retirada. O copolímero de poli (ácido láctico-co-glicólico) (PLGA) é um tipo de biomaterial temporário, rotineiramente utilizado na medicina na forma de fios de sutura e implantes ortopédicos. A mistura do PLGA com o poli (isopreno) resulta em uma blenda (PLGA / PI), de alta resistência e tenacidade, que foi desenvolvida pelo Laboratório de Biomateriais do Instituto de Engenharia da UFRGS. Entretanto, não existem estudos “in vivo” testando a reação óssea desta blenda. Objetivo: Testar a histotoxicidade da blenda de PLGA / PI em relação ao biopolímero já consagrado PLGA. Método: Foram utilizados 46 ratos machos wistar (Rattusnorvegicus - linhagem albina), divididos em 2 grupos conforme o material implantado (PLGA ou PLGA / PI) na calota craniana, e subdivididos em tempos de morte (15, 30, 60 e 90 dias). Os procedimentos foram realizados na Unidade de Experimentação Animal (UEA) do Hospital de Clínicas de Porto Alegre (HCPA). Após a morte, a calota craniana foi retirada, submetida ao exame histopatológico e aplicado o escore de Dadas e cols (14) modificado. Resultados: A diferença da histotoxicidade dos dois materiais não foi significativa nos períodos 15, 30 e 90 dias, porém foi significativa no período 60 dias. Conclusão: A histotoxicidade do PLGA / PI, ao final do estudo (90 dias), foi semelhante ao PLGA, demonstrando equivalência em longo prazo. O período de 60 dias pós-cirúrgico (grupo da blenda) foi o único em que a histotoxicidade mostrou-se significativamente maior. Mais estudos devem ser feitos para melhorar o entendimento desta variação. / Introduction: Clinical application of biomaterials is expanding to various medical specialties. Among the different types of biomaterials, those classified as temporary deserve special attention because they are assimilated by the body after exercising their function, thereby avoiding surgical procedure for their removal. Co-polymer poly (lactic-co-glycolic acid) (PLGA) is a type of temporary biomaterial, routinely used in medicine as suture threads and orthopedic implants. The mixture of PLGA with poly (isoprene) results in a high-strength and thoughness blend (PLGA / PI), developed by the Biomaterials Laboratory of the Engineering Institute/ UFRGS. However, there are no studies “in vivo” testing the bone reaction of that blend. Objective: To Test histotoxicity of PLGA / PI blend over the already established biopolymer, PLGA. Method: Forty six male Wistar rats (Rattus norvegicus – albino strain), divided into 2 groups according to the material (PLGA or PLGA / PI) implanted in the skull and sub divided into periods of death (15, 30, 60 and 90 days). The procedures were developed in the Animal Experiment Unit (AEU) of Hospital de Clínicas de Porto Alegre (HCPA). After death, the skull was removed, submitted to histopathologic examination and the modified Dadas’ et all score was used (14). Results: The histotoxicity difference of the two materials was not significant in the periods of 15, 30 and 90 days, but it was significant in the period of 60 days. Conclusion: At the end of the study (90 days), the PLGA / PI histotoxicity was similar to PLGA, showing longterm equivalence. The 60-day post-surgical period was the only one in which histotoxicity was significantly higher (blend group). More studies shall be done in in order to better understand that variation.
3

Estudo experimetal comparativo da histotoxicidade entre o copolímero de poli (ácido láctico-co-glicólico) e a blenda poli (ácido láctico-co-glicólico) / poli (isopreno)

Kim, Jung Ho January 2012 (has links)
Introdução: A aplicação clínica de biomateriais está se expandindo para diversas especialidades médicas. Dentre os diversos tipos de biomateriais, os classificados como temporários merecem atenção especial, pois são assimilados pelo organismo após exercerem sua função, evitando, assim, procedimento cirúrgico para sua retirada. O copolímero de poli (ácido láctico-co-glicólico) (PLGA) é um tipo de biomaterial temporário, rotineiramente utilizado na medicina na forma de fios de sutura e implantes ortopédicos. A mistura do PLGA com o poli (isopreno) resulta em uma blenda (PLGA / PI), de alta resistência e tenacidade, que foi desenvolvida pelo Laboratório de Biomateriais do Instituto de Engenharia da UFRGS. Entretanto, não existem estudos “in vivo” testando a reação óssea desta blenda. Objetivo: Testar a histotoxicidade da blenda de PLGA / PI em relação ao biopolímero já consagrado PLGA. Método: Foram utilizados 46 ratos machos wistar (Rattusnorvegicus - linhagem albina), divididos em 2 grupos conforme o material implantado (PLGA ou PLGA / PI) na calota craniana, e subdivididos em tempos de morte (15, 30, 60 e 90 dias). Os procedimentos foram realizados na Unidade de Experimentação Animal (UEA) do Hospital de Clínicas de Porto Alegre (HCPA). Após a morte, a calota craniana foi retirada, submetida ao exame histopatológico e aplicado o escore de Dadas e cols (14) modificado. Resultados: A diferença da histotoxicidade dos dois materiais não foi significativa nos períodos 15, 30 e 90 dias, porém foi significativa no período 60 dias. Conclusão: A histotoxicidade do PLGA / PI, ao final do estudo (90 dias), foi semelhante ao PLGA, demonstrando equivalência em longo prazo. O período de 60 dias pós-cirúrgico (grupo da blenda) foi o único em que a histotoxicidade mostrou-se significativamente maior. Mais estudos devem ser feitos para melhorar o entendimento desta variação. / Introduction: Clinical application of biomaterials is expanding to various medical specialties. Among the different types of biomaterials, those classified as temporary deserve special attention because they are assimilated by the body after exercising their function, thereby avoiding surgical procedure for their removal. Co-polymer poly (lactic-co-glycolic acid) (PLGA) is a type of temporary biomaterial, routinely used in medicine as suture threads and orthopedic implants. The mixture of PLGA with poly (isoprene) results in a high-strength and thoughness blend (PLGA / PI), developed by the Biomaterials Laboratory of the Engineering Institute/ UFRGS. However, there are no studies “in vivo” testing the bone reaction of that blend. Objective: To Test histotoxicity of PLGA / PI blend over the already established biopolymer, PLGA. Method: Forty six male Wistar rats (Rattus norvegicus – albino strain), divided into 2 groups according to the material (PLGA or PLGA / PI) implanted in the skull and sub divided into periods of death (15, 30, 60 and 90 days). The procedures were developed in the Animal Experiment Unit (AEU) of Hospital de Clínicas de Porto Alegre (HCPA). After death, the skull was removed, submitted to histopathologic examination and the modified Dadas’ et all score was used (14). Results: The histotoxicity difference of the two materials was not significant in the periods of 15, 30 and 90 days, but it was significant in the period of 60 days. Conclusion: At the end of the study (90 days), the PLGA / PI histotoxicity was similar to PLGA, showing longterm equivalence. The 60-day post-surgical period was the only one in which histotoxicity was significantly higher (blend group). More studies shall be done in in order to better understand that variation.
4

Estudo experimetal comparativo da histotoxicidade entre o copolímero de poli (ácido láctico-co-glicólico) e a blenda poli (ácido láctico-co-glicólico) / poli (isopreno)

Kim, Jung Ho January 2012 (has links)
Introdução: A aplicação clínica de biomateriais está se expandindo para diversas especialidades médicas. Dentre os diversos tipos de biomateriais, os classificados como temporários merecem atenção especial, pois são assimilados pelo organismo após exercerem sua função, evitando, assim, procedimento cirúrgico para sua retirada. O copolímero de poli (ácido láctico-co-glicólico) (PLGA) é um tipo de biomaterial temporário, rotineiramente utilizado na medicina na forma de fios de sutura e implantes ortopédicos. A mistura do PLGA com o poli (isopreno) resulta em uma blenda (PLGA / PI), de alta resistência e tenacidade, que foi desenvolvida pelo Laboratório de Biomateriais do Instituto de Engenharia da UFRGS. Entretanto, não existem estudos “in vivo” testando a reação óssea desta blenda. Objetivo: Testar a histotoxicidade da blenda de PLGA / PI em relação ao biopolímero já consagrado PLGA. Método: Foram utilizados 46 ratos machos wistar (Rattusnorvegicus - linhagem albina), divididos em 2 grupos conforme o material implantado (PLGA ou PLGA / PI) na calota craniana, e subdivididos em tempos de morte (15, 30, 60 e 90 dias). Os procedimentos foram realizados na Unidade de Experimentação Animal (UEA) do Hospital de Clínicas de Porto Alegre (HCPA). Após a morte, a calota craniana foi retirada, submetida ao exame histopatológico e aplicado o escore de Dadas e cols (14) modificado. Resultados: A diferença da histotoxicidade dos dois materiais não foi significativa nos períodos 15, 30 e 90 dias, porém foi significativa no período 60 dias. Conclusão: A histotoxicidade do PLGA / PI, ao final do estudo (90 dias), foi semelhante ao PLGA, demonstrando equivalência em longo prazo. O período de 60 dias pós-cirúrgico (grupo da blenda) foi o único em que a histotoxicidade mostrou-se significativamente maior. Mais estudos devem ser feitos para melhorar o entendimento desta variação. / Introduction: Clinical application of biomaterials is expanding to various medical specialties. Among the different types of biomaterials, those classified as temporary deserve special attention because they are assimilated by the body after exercising their function, thereby avoiding surgical procedure for their removal. Co-polymer poly (lactic-co-glycolic acid) (PLGA) is a type of temporary biomaterial, routinely used in medicine as suture threads and orthopedic implants. The mixture of PLGA with poly (isoprene) results in a high-strength and thoughness blend (PLGA / PI), developed by the Biomaterials Laboratory of the Engineering Institute/ UFRGS. However, there are no studies “in vivo” testing the bone reaction of that blend. Objective: To Test histotoxicity of PLGA / PI blend over the already established biopolymer, PLGA. Method: Forty six male Wistar rats (Rattus norvegicus – albino strain), divided into 2 groups according to the material (PLGA or PLGA / PI) implanted in the skull and sub divided into periods of death (15, 30, 60 and 90 days). The procedures were developed in the Animal Experiment Unit (AEU) of Hospital de Clínicas de Porto Alegre (HCPA). After death, the skull was removed, submitted to histopathologic examination and the modified Dadas’ et all score was used (14). Results: The histotoxicity difference of the two materials was not significant in the periods of 15, 30 and 90 days, but it was significant in the period of 60 days. Conclusion: At the end of the study (90 days), the PLGA / PI histotoxicity was similar to PLGA, showing longterm equivalence. The 60-day post-surgical period was the only one in which histotoxicity was significantly higher (blend group). More studies shall be done in in order to better understand that variation.
5

Μελέτη της προσρόφησης πολυμερών σε πορώδη υλικά

Μαγιάφα, Μαρία 04 February 2014 (has links)
Στην εργασία αυτή μελετήθηκε o ρυθμός ροής υδατικών διαλυμάτων, σε διάφορα pH περιβάλλοντος, διαμέσου ενός νανοπορώδους υλικού τροποποιημένου με πολυμερικές ψήκτρες. Ειδικότερα, ερευνήθηκε το σύστημα του σύνθετου υλικού πορώδους ανοδικής αλουμίνας με πολυμερικές ψήκτρες του γραμμικού δισυσταδικού συμπολυμερούς πολύ(Ισοπρένιου)–b–πολυ(Ακρυλικού Οξέους) (ΙΑΟ). Η προσρόφηση καθώς και η κινητική προσρόφησης του IAO στο νανοπορώδες υλικό διερευνήθηκε κυρίως μέσω τεχνικών δονητικής φασματοσκοπίας. Πιο συγκεκριμένα με τεχνικές υπερύθρου μετασχηματισμού κατά Φουριέ (Fourier Transform Infrared Spectroscopy ή FT-IR), εγγύ υπερύθρου (N-IR) και Αποσβεννύμενη Ολική Ανάκλαση στο μέσο υπέρυθρο (ATR-IR). Ακόμη, με σκοπό την ποσοτικοποίηση της προσροφημένης ποσότητας του ΙΑΟ εφαρμόστηκε η τεχνική της θερμοσταθμικής ανάλυσης (TGA). Τέλος, για την απόκτηση μιας λεπτομερούς εικόνας σχετικά με τη δομή του σύνθετου νανο-πορώδους υλικού τα δείγματα χαρακτηρίστηκαν και με ηλεκτρονική μικροσκοπία (SEM/EDS). / In the present study the flow rate of aqueous solutions of different pH values through a nanoporous material functionalized with polymeric brushes was investigated using spectroscopic and thermogravimetric methods. In particular, the system under study was a composite material of porous anodic alumina with polymeric brushes of the diblock copolymer poly(Isoprene)–b–poly(Acrylic Acid) (IAO). The adsorption and adsorption kinetics of the IAO onto nanoporous alumina were explored mainly through techniques of vibrational spectroscopy. More specifically Fourier Transformed Infrared Spectroscopy (FT-IR), Near Infrared (N-IR) and Attenuated Total Reflectance (ATR-IR) were employed for this purpose. Moreover, for the quantification of the adsorbed amount of IAO, thermogravimetric analysis was applied (TGA). Finally, to obtain a comprehensive picture of the structure of the nanoporous composite materials used in this study, samples were additionally characterized by electron microscopy (SEM/EDS).

Page generated in 0.0506 seconds