• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Modelagem e análise de tensão em estrutura óssea com implante metálico, através do método dos elementos finitos /

Hayasaki, Cláudio Luís. January 2007 (has links)
Orientador: Edson Antonio Capello Sousa / Banca: Bento Rodrigues de Pontes Junior / Banca: Antonio Pedro Clapis / Resumo:O objetivo deste trabalho foi simular pelo método dos Elementos Finitos a estrutura óssea de coelhos (tíbia), quando sujeita a uma determinada carga transversal estática, e validar o modelo numérico obtido no software Ansys. O comportamento mecânico de estruturas biomecânicas, tais como tíbia, fêmur, ossos em geral, são muito similares a estruturas mecânicas, por exemplo vigas, barras, tubos, pontes, treliças, e outros. Houve algumas dificuldades em gerar o modelo tridimensional; pode-se numerálas. A primeira foi construir o modelo exatamente com todas as superfícies irregulares. Para resolver este problema, mediu-se ao longo do comprimento da tíbia a cada 5 milímetros, começando na posição do implante. A segunda dificuldade foi separar materiais distintos que constituem o osso, por exemplo, osso cortical e osso medular, bem como o da região do implante de titânio. Diferenciou-se as regiões onde ocorrem cada tipo de osso, incluindo a região osseointegrada. A terceira dificuldade foi representar a carga que agiu sobre a estrutura óssea. Adotou-se a carga como uma pressão distribuída que agiu sobre a região do implante. A quarta dificuldade foi adaptar e reconhecer os termos da bioengenharia, que representam novidades para os engenheiros mecânicos e para os engenheiros em geral. O modelo de elementos finitos foi simulado pelo software Ansys, onde foram aplicados elementos tetraédricos. Para validar o modelo, os resultados foram checados com a revisão bibliográfica. Foram comparados os resultados de tensões máximas geradas pelo modelo com as tensões máximas obtidas experimentalmente. Concluiu-se que a aproximação foi satisfatória,considerando a precisão do modelo construído computacionalmente. / Abstract: The goal of this paper was to simulate through the Finite Element Method, the bone structure of rabbits (tibia), when subjected to a determined static transversal loading, and validate the numerical model obtained in the software Ansys. The mechanical behaviour of biomechanical structures, as tibia, femur, bones in general, are too much similar as mechanical structures, for example beams, bars, pipes, bridges, trusses, and so on. There were several difficulties in generating the three-dimensional model; we can numerate them. The first was to build the model exactly with all the irregular surfaces. For solve this problem, we measured along the length of the tibia for each five millimeters, beginning on the position of the implant. The second difficulty was to separate different materials that constitute the body of the bone, for instance, the cortical bone and the medular bone, as well as the region of implant of titanium. We differentiate the regions where each type of bone occurs, including the osseointegrated region. The third difficulty was to represent the load that acted over the bone structure. We adopt the load as a distributed pressure located over the region of the implant. The finite element model was simulated by Ansys software, where was applied tetrahedricals elements. For validating the model, the results were checked with the bibliography revision. We compare the results of intensity of maximal stress generated by the model with the maximal stress obtained experimentally. We conclude that was a reasonable approach, considering the accuracy of the constructed model. / Mestre
92

Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de prótese dentária / Analysis of microbial contamination of device acrylic manufactured in dental laboratories

Temóteo, Guilherme de Alencar January 2014 (has links)
TEMÓTEO, Guilherme de Alencar. Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de próteses dentárias. 2014. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2014-07-21T11:40:44Z No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-07-21T11:50:50Z (GMT) No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Made available in DSpace on 2014-07-21T11:50:50Z (GMT). No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) Previous issue date: 2014 / The possible presence of potentially pathogenic microorganisms in denture newly arrived from prosthetic laboratories should be considered. This study evaluated the level of bacterial and fungal contamination of specimens of acrylic resin made in 14 dental laboratories registered with the Regional Council of Dentistry of Ceará, Fortaleza. Each laboratory was asked to fabricate 10 specimens of acrylic resin, from standard models of sterile silicone addition, unaware of the research objectives. Specimens received from laboratories were placed in individual tubes containing BHI broth, incubated at 37°C for 48 hours and then removed, washed and placed in sterile saline and stirred for microbial detachment. The suspension obtained was diluted (1:100, 1:1000) and plated on blood agar plates, and Sabouraud Dextrose Agar and Agar HiCrome ICU by incubation for 48 hours at 37°C. The number of colony forming units (CFU) bacterial and fungal viable was obtained, besides the identification and quantification of some species of bacteria, comparing the laboratory by means of the Kruskal-Wallis and Dunn (α = 0.05) tests. There was contamination originating from all laboratories analyzed, with a mean CFU counts of 101438 bacteria and 71047 fungi. Pseudomonas spp was the most prevalent microorganism identified (p < 0.05). It was concluded that there is a risk of contamination with potentially pathogenic bacteria and fungi in prosthetic devices newly arrived from dental laboratories. / A possível presença de microorganismos potencialmente patogênicos em próteses dentárias recém-chegadas dos laboratórios protéticos deve ser considerada. Este estudo avaliou o nível de contaminação bacteriana e fúngica de espécimes de resina acrílica confeccionados em 14 laboratórios de prótese dentária, inscritos no Conselho Regional de Odontologia do Ceará, na cidade de Fortaleza. Cada laboratório foi solicitado a confeccionar 10 espécimes de resina acrílica, a partir de modelos padronizados de silicona de adição estéreis, desconhecendo os objetivos da pesquisa. Os espécimes recebidos dos laboratórios foram colocados em tubos individuais contendo BHI caldo e incubados a 37°C por 48 horas e, em seguida, removidos, lavados, colocados em solução salina estéril e agitados para desprendimento microbiano. A suspensão obtida foi diluída em 1:100, 1:1000 e semeada em placas com Ágar Sangue, Sabouraud Dextrose Ágar e HICrome UTI Ágar®, para incubação por 48 horas a 37°C. Foi obtido o número de unidades formadoras de colônias (UFC) bacterianas e fúngicas viáveis, além da identificação e quantificação de algumas espécies de bactérias, comparando-se os laboratórios por meio dos testes de Kruskall-Wallis e Dunn (α=0.05). Houve contaminação advinda de todos os laboratórios analizados, com uma contagem de UFC média de 101438 de bactérias e 71047 de fungos. Pseudomonas spp foi o microorganismo a mais prevalente identificado (p<0,05). Foi concluido que existe risco de contaminação por bactérias potencialmente patogênicas e fungos em dispositivos protéticos recém chegados dos laboratórios.
93

Análise e comparação da interface implante/pilar de pilares de zircônia usinados por tecnologia CAD/CAM sobre implantes HE.

Rodríguez Ivich, Elí Jair January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:45:20Z (GMT). No. of bitstreams: 1 340525.pdf: 1688167 bytes, checksum: 70875b398c49ad9d4d9b2835008966ec (MD5) Previous issue date: 2016 / O objetivo deste estudo foi determinar a precisão marginal de diferentes pilares de zircônia usinados por sistemas de CAD/CAM instalados sobre implantes Hexágono Externo. Foram utilizados doze implantes de hexágono externo Easy Grip (Conexão Sistema de Prótese Ltda) de 10mm de comprimento e 4.0 mm de diâmetro. Foram utilizados quatro tipos de pilares: Grupo 1 Pilares de titânio pré-fabricados (30 N); Grupo 2 Pilares de zircônia: Dental Wings (20 N); Grupo 3 Pilares de zircônia: 3Shape (20 N); Grupo 4 Pilares Ti-base: (CEREC, Sirona) (35 N). As amostras foram apreendidas em um porta-amostra e segmentadas ao longo eixo. A espessura da interface implante-pilar foi mensurada por microscopia óptica em 6 diferentes pontos. Os valores da análise de variância resultaram que os tamanhos da interface do grupo 1 (Ti) foram significativamente menores do que os observados nos pilares ceâmicos (P <0,05). Os valores da interface do grupo 1 (Ti) não foram significativamente diferentes aos valores do grupo 4 (P>0.05). No entanto, foi encontrada uma diferença significativa entre as interfaces dos pilares de titânio (grupo 1 e 4) em comparação com os pilares de zircônia (grupo 2 e 3). Dentro dos limites deste estudo, mostrou-se que os pilares de zircônia não podem ser usinados com o mesmo grau de precisão que os pilares metálicos. As consequências mecânicas e o risco de infiltração microbiana da interface implante-pilares de zircônia devem ser avaliados em investigações clínicas. <br> / Abstract : The aim of this study was to determine the marginal accuracy of different zirconia abutments machined by CAD/CAM systems screwed on external hexagon implants. Twelve external hexagon (HE) ( Easy Grip, Prosthesis System Connection Ltd.) implants (10mm long and 4.0 mm) were used. Four types of abutments were used: Group 1 - prefabricated titanium abutments (30 N); Group 2 - zirconia abutments: Dental Wings (20 N); Group 3 - zirconia abutments: Tree Shape (20 N); Group 4 - Ti-base abutmetns: CEREC (35 N). The samples were placed in a sample port and segmented through the long axis. The thickness of the implant-abutment interface was measured by optical microscopy in 6 different points. One-way ANOVA have shown that the interfacial gaps from group 1 (Ti) were significantly lower than those observed in zirconia abutments (P <0.05), but were not significantly different from the values of Group 4 (P> 0.05). However, a significant difference was found between the interfaces of titanium abutments (Groups 1 and 4) compared with the zirconia abutments (Groups 2 and 3). Within the limits of this study showed that the zirconia abutments can not be machined with the same degree of precision as the metal abutments. The mechanical effects and the risk of microbial infiltration of zirconia implant-abutment interface should be evaluated in clinical research.
94

Estudo clínico comparativo da manutenção do aprofundamento de sulco nas vestibuloplastias mandibulares, através das técnicas de tuneilização submucosa e epitelização secundária

Marques, Eduvaldo Silvino de Brito [UNESP] 17 June 1993 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:55Z (GMT). No. of bitstreams: 0 Previous issue date: 1993-06-17. Added 1 bitstream(s) on 2015-12-10T14:29:09Z : No. of bitstreams: 1 000024654.pdf: 1012771 bytes, checksum: 98e16a90ccb14b054b40647b125162c8 (MD5) / Inúmeras tem sido as tentativas dos mais variados cirurgiões bucais, em realizar técnicas cirúrgicas com o intuito de melhorar os rebordos alveolares para a colocacão de próteses totais. Basicamente as técnicas empregadas para esta finalidade estão divididas em quatro grupos, que são: tuneilização submucosa; epitelização secundária; enxerto de tecidos moles e transposição de retalhos. Os pacientes foram selecionados na clínica de Cirurgia e Traumatologia Buco-Maxilo-Facial, da Faculdade de Odontologia de São José dos Campos em número de vinte, dentre aqueles que necessitavam de próteses totais e que tinham dificuldades na utilização das mesmas no que se refere a estabilidade e retenção. Foram dividas em dois grupos, e submetidos respectivamente as técnicas cirúrgicas de tuneilização submucosa com uso de goteiras, e epitelização secundária através da técnica de Clark, e, avaliados no que concerne a estabilidade após doze meses. Os resultados foram obtidos através de exames clínicos e radiográficos antes e após a realização das cirurgias, sendo que de um modo geral, são próximos aos relatados na literatura, atingindo-se critérios satisfatórios de funcionabilidade / For some time, oral surgeons have tried several surgical procedures to improve the alveolar ridge for prosthetic appliance construction. The techniques used for this purpose are divided into four groups: submucosal vestibuloplasty; secondary epithelization; soft tissue grafting and transpositional flaps. Twenty patients who had problems to wear dentures due to unsatisfactory retention and stability were selected at the Oral and MaxilloFacial Surgery and Traumatology Clinic of Dental School of São José dos Campos. They were divided in two groups and operated by submucosal vestibuloplasty using stents and secondary epithelization vestibuloplasty by Clark's technique and were evaluated twelve months after operations in relationship of the sulcus depth. The results were obtained by clinical and radiological examination before and after surgery, and they are similar to those found in the literature reaching satisfactory functional judgement
95

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever

Mesquita, Alfredo Mikail Melo [UNESP] 30 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-30Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 mesquita_amm_dr_sjc.pdf: 511472 bytes, checksum: bdcad35472f1cab510c82684030d9a0f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn’t difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated.
96

Taxa de sobrevida, carga para fratura e análise por elementos finitos de dentes anteriores restaurados com facetas cerâmicas variando o desenho do preparo

Bergoli, César Dalmolin [UNESP] 01 August 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-01Bitstream added on 2014-06-13T20:06:13Z : No. of bitstreams: 1 000757600.pdf: 2238658 bytes, checksum: e4af2fec93f2c954b6aa895e20cc674a (MD5) / O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 – Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos... / The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values
97

Disfunção craniomandibular em pacientes desdentados totais com alteração da dimensão vertical. -

Ricci, Weber Adad. January 2002 (has links)
Orientador : Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Helena de Freitas Oliveira Paranhos / Resumo: O presente estudo procurou avaliar a prevalência de sinais e sintomas de disfunção craniomandibular (D.C.M.) em 100 pacientes desdentados totais, portadores de próteses totais duplas, dos quais 58 apresentavam dimensão vertical normal (Grupo 1) e 42 dimensão vertical com alteração (Grupo 2). Os dados foram obtidos a partir de um índice anamnésico simplificado e de exame físico. Após a análise estatística, foi possível observar que: 1. em relação ao índice anamnésico utilizado, a análise estatística mostrou haver associação entre a dimensão vertical e os sintomas de D.C.M. (p=0,016); 2. quanto ao número de regiões sensíveis à palpação muscular, foi constatada uma associação estatisticamente significante com a dimensão vertical (p=0,014); 3. quando avaliados os grupos musculares isoladamente, apenas a palpação intraoral do músculo pterigóideo lateral apresentou associação estatisticamente significante com a dimensão vertical (p=0,05). Conclui-se, por meio deste estudo, que existe uma evidência de associação entre a dimensão vertical e os sinais e sintomas de D.C.M. considerando-se a metodologia empregada e a população estudada. / Abstract: The present study evaluated the prevalence of signs and symptoms of temporomandibular disorders in 100 patients wearing complete upper and lower dentures, 58 with normal vertical dimension (Group 1) and 42 with altered vertical dimension (Group 2). The data were obtained utilizing a simplified anamnestic index and of physical exam. After the statistical analysis, it was possible to conclude that: 1. there was a significant correlation between the vertical dimension and the symptoms of temporomandibular disorders, when utilizing the anamnestic index (p=0,016); 2. there was a significant correlation between the vertical dimension and the number of tenderness sites during muscle palpation (p=0,014); 3. when appraised the muscular groups separately, just the tenderness to the intra-oral palpation of the lateral pterygoid muscle showed a statistically significant correlation with the vertical dimension (p=0,05). It could be concluded that there was an association between the vertical dimension and the signs and symptoms of temporomandibular disorders, for this sub population that has been analysed. / Mestre
98

Efeito da terapia cirúrgica anti-infecciosa sobre biomarcadores imunológicos em pacientes portadores de peri-implantite

Zani, Sabrina Rebollo January 2015 (has links)
Made available in DSpace on 2015-06-16T02:06:48Z (GMT). No. of bitstreams: 1 000470529-Texto+Completo-0.pdf: 1858726 bytes, checksum: 5770182d321cd5a1e49c65dc3d839f41 (MD5) Previous issue date: 2015 / The objective of the present study was to evaluate the effects of an antiinfective surgical therapy over 20 peri-implant crevicular fluid biomarkers in patients with peri-implantitis and to compare these immunologic profiles with the clinical parameters. Fifty-two patients presenting implants affected by peri-implantitis were classified into 4 groups according with probing depth and the presence of bleeding and/or suppuration at mesio-buccal site of each implant with periimplantitis. Clinical parameters were measured and PICF samples were collected from the mesio-buccal site of every implant. All subjects were submitted to anti-infective surgical therapy. Clinical parameters and PICF biomarkers were re-measured at 6 and 12 months after treatment. PICF samples were analyzed using multiplex bead immunoassay for 20 biomarkers. Differences over time were analyzed using generalized estimating equations. The significance level established for all analyses was 5% (p <0. 05).The results demonstrated a significant reduction of the clinical parameters post-therapy. However, it was observed a significant increase of some pro-inflammatory biomarkers levels (IL-1β, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L). And IL-13 was the only anti-inflammatory cytokine, which had a significant increase in its levels after anti-infective surgical therapy. / O presente estudo tem por objetivo avaliar o efeito da terapia cirúrgica anti-infecciosa sobre 20 biomarcadores imunológicos em pacientes com periimplantite, e comparar esse perfil imunológico com os parâmetros clínicos. Foram selecionados 52 pacientes que apresentavam implantes com peri-implantite, os quais foram divididos em 4 grupos de acordo com a profundidade de sondagem e presença de sangramento e/ou supuração no sítio mésio-vestibular de cada implante com peri-implantite. Os parâmetros clínicos foram mensurados e amostras de fluido crevicular peri-implantar, coletadas do sítio mésio-vestibular de cada implante. Todos pacientes foram submetidos à terapia cirúrgica anti-infecciosa e reavaliados 6 e 12 meses após o tratamento. As amostras de fluido crevicular foram analisadas através do ensaio imunológico Luminex (multi-análise com micro-esferas) para detecção de 20 biomarcadores. Diferenças entre os grupos em relação aos níveis desses biomarcadores ao longo do tempo foram analisadas estatisticamente através das equações de estimação generalizadas. O nível de significância estabelecido foi de 5% (p < 0,05).Os resultados demonstraram reduções significativas dos parâmetros clínicos, entretanto mostraram aumentos significativos dos níveis de alguns biomarcadores pró-inflamatórios (IL-1β, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L) após a terapia cirúrgica. A IL-13 foi a única citocina anti-inflamatória que mostrou aumento significativo após o tratamento.
99

Taxa de sobrevida, carga para fratura e análise por elementos finitos de dentes anteriores restaurados com facetas cerâmicas variando o desenho do preparo /

Bergoli, César Dalmolin. January 2013 (has links)
Orientador: Marco Antonio Bottino / Co-orientador : Josete Barbosa Cruz Meira / Co-orientador : Luiz Felipe Valandro Soares / Banca: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Renata Faria / Banca: Carlos José Soares / Resumo: O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 - Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos... / Abstract: The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values / Doutor
100

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical /

Santos, Vivian Mayumi Miyazaki. January 2013 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Eduardo Shigueyuki Uemura / Banca: Luis Gustavo de Oliveira Vasconcellos / Resumo: O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / Abstract: The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant / Mestre

Page generated in 0.0285 seconds