• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 163
  • 5
  • 3
  • Tagged with
  • 171
  • 125
  • 29
  • 28
  • 26
  • 25
  • 24
  • 23
  • 19
  • 18
  • 18
  • 18
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Utilização dos produtos obtidos por sensoriamento remoto na caracterização da qualidade do ar na Região Metropolitana de São Paulo / Use of remote sensing derived products in the air quality characterization over the Metropolitan Area of São Paulo.

Luciene Natali 28 July 2008 (has links)
O objetivo desse trabalho foi estudar a relação entre profundidade óptica de aerossóis (AOD), obtida por sensoriamento remoto, e a concentração de material particulado (MP10 e MP2,5) medida próximo à superfície sobre a Região Metropolitana de São Paulo (RMSP). A profundidade óptica foi derivada a partir de medidas de radiâncias fornecidas pelos sensores MODIS. Estes sensores estão posicionados a bordo dos satélites EOS-TERRA e EOS-AQUA, operados pela NASA. As concentrações de MP10 e MP2,5 foram obtidas nas estações da rede operacional da CETESB. Foram feitos alguns estudos de caso considerando diferentes situações atmosféricas, aos quais se aplicou a metodologia proposta por Castanho (2005) que busca reduzir as incertezas na determinação da profundidade óptica derivada do MODIS e identificar qual o modelo de aerossol é mais adequado para aplicação em estudos de qualidade do ar. Os valores de AOD calculados para as diferentes situações foram comparados com aqueles obtidos pela AERONET e com as concentrações anteriormente citadas, buscando uma validação dos mesmos. Valores médios de AOD foram calculados para áreas de 10 km x 10 km ao redor das estações de monitoramento do MP. Testes foram realizados para verificar os efeitos de sazonalidade, da quantidade de água na coluna atmosférica, da resposta da AOD por faixas de concentração de MP10, da geometria do sensor, da presença de nuvens e da presença de aerossol acima da Camada de Mistura (CM). Os resultados foram apresentados por estações com o objetivo de se visualizar diferentes condições sobre a região estudada. Alguns dos fatores relevantes observados durante a comparação entre a concentração de MP10 e a AOD foram: a influência do período do ano e da quantidade de água na coluna atmosférica. A geometria do sensor foi fator determinante para melhora das correlações, quando limitado o ângulo de espalhamento em 140°. Situações em que há ausência de nuvens, identificadas através de imagens do MODIS no visível, também apresentaram melhores resultados. Outro fator de extrema importância foi a estrutura vertical da CM. Através de medidas obtidas de um LIDAR foi verificado que a presença de aerossóis acima da CM, a qual é determinada principalmente pelas condições atmosféricas, é determinante para as correlações entre AOD e o MP. / The main purpose of this work was to study the relationship between the Aerosol Optical Depth (AOD), obtained by remote sensing, and the particulate material concentration (PM10 and PM2.5), near to the surface over the Metropolitan Area of Sao Paulo (MASP). The Aerosol Optical Depth was retrieved based on reflectance measurements provided by MODIS sensors. These sensors are carried aboard EOS-TERRA and EOS-AQUA satellites, which are operated by NASA. The PM10 and PM2.5 concentrations were obtained in the CETESB operational network. Case studies were performed, considering several atmospheric conditions, applying the methodology proposed by CASTANHO (2005), designed both to reduce the uncertainty in the determination of the MODIS derived Optical Depth and to identify which aerosol model is more appropriated for air quality studies. Some derived results were compared with AERONET data and with the previously mentioned concentrations as a cross-check test. Mean AOD values were calculated using 10 km x 10 km area ground around PM monitoring stations. Tests were performed to estimate the effects of seasonality, atmospheric column water content, AOD response to PM10 concentration, sensor geometry, clouds and aerosol concentration above the Mixing Layer (ML). To stress the different conditions of the studied region, the results were presented considering each station. Some of the relevant observed factors in the PM10 concentration and AOD comparison were the year period influence and the atmospheric column water content. The sensor geometry was an important factor to the improvement of the obtained correlations when the scattering angle was bounded to 140°. Cloudless situations, identified by MODIS true color images, also improved the results. Another important factor was the Mixing Layer vertical structure. Using LIDAR measurements it was verified that the presence of aerosols above the ML, which is determined mainly by atmospheric conditions, is crucial for the correlations between AOD and PM.
52

Caracterização geofísica da estrutura de impacto de Araguainha, MT/GO / Gephysical Characterization of the Araguainha impact structure, MT/GO.

Marcos Alberto Rodrigues Vasconcelos 17 April 2007 (has links)
Araguainha é a maior e mais bem exposta cratera complexa da América do Sul, formada em sedimentos horizontais da Bacia do Paraná. Sua portentosa estrutura com aproximados 40 km de diâmetro e 25 km de cavidade transiente revela um contraste negativo de densidade e susceptibilidade magnética na região do soerguimento central. Esta feição permite inferir um limite de propriedade física entre o Núcleo Central Soerguido (NCS) e o Embasamento Granítico Soerguido (EGS), que por sua vez apresenta baixa razão de Koenigsberger. A caracterização geofísica de Araguainha é sustentada por modelamento 2,5D com base em informações gravimétricas, aeromagnéticas e magnéticas terrestres, o que permite classificá-la como uma estrutura concêntrica e simétrica, com profundidade média do embasamento a 1,0 km, exceto para a borda sul, que apresenta soerguimento mais acentuado. A interface embasamento/sedimento é seccionada por pares espelhados de falhas radiais que surgem no estágio de modificação da cratera. Estas estruturas rúpteis conferem as maiores profundidades à região da bacia anelar e promovem constricção dos sedimentos com tensão horizontal radial. A observação e interpretação destas deformações permitem caracterizar Araguainha como uma estrutura de impacto de domínio rúptil-dúctil. / Araguainha is the largest and the best-exposed complex crater of South America, formed in horizontal sediments of the Paraná Basin. Its portentous structure with 40 km in diameter and 25 km of transient cavity reveals a negative contrast of density and magnetic susceptibility in the central uplift. That feature allows to infer a limit of physical property between the uplifted central core and the uplifted granite basement, which shows a low Konigsberger?s ratio. The geophysical characterization of Araguainha is sustained by 2,5D modeling with gravity, aeromagnetic, and ground magnetic information and It allows to classify it as a concentric, symmetrical structure, with average basement depth of 1.0 km, except in the southern rim, that shows a bigger uplift. The basement/sediment interface is cut by specular pairs of radial faults that appears in the modification stage of the crater. These brittle structures are responsible for the biggest depths in the annular basin region, and they promote a sediment constriction with horizontal radial tension. The observation and interpretation of these deformations allow to characterize Araguainha as an impact brittle-ductile domain structure.
53

Crescimento da grama bermuda DiscoveryTM irrigada por gotejamento subsuperficial, sob tensões de água no solo /

Almeida, Amanda Maria de January 2019 (has links)
Orientador: João Carlos Cury Saad / Resumo: O adequado manejo de irrigação aliado ao uso de sistemas de irrigação por gotejamento subsuperficial podem maximizar a eficiência de uso da água como fator de produção em cultivos de gramados esportivos e ornamentais. Objetivou-se avaliar os parâmetros fitotécnicos da grama bermuda DiscoveryTM sob tensões de água no solo em gotejamento subsuperficial a diferentes profundidades. O experimento foi conduzido na Faculdade de Ciências Agronômicas (FCA) da Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP) na cidade de Botucatu-SP, no período de 05 de março de 2018 a 01 de junho de 2019. O delineamento experimental adotado foi de blocos em faixas, com quatro repetições, sendo os tratamentos constituídos por quatro tensões de água no solo (30, 40, 50 e 60 kPa) e três profundidades de instalação da linha lateral (0, 5 e 10 cm abaixo do tapete). Foram avaliados nos meses de janeiro a maio de 2019 os parâmetros fitotécnicos: medida indireta de clorofila, altura de folhas, massa de aparas secas, comprimento e massa seca de raízes. Ao final, avaliou-se também se houve obstrução dos emissores. A medida indireta de clorofila, altura de folhas e massa de aparas secas diminuíram com as tensões de água no solo acima de 30 kPa e com o aumento da profundidade de instalação da linha lateral. As maiores expressões do comprimento radicular e da massa seca do gramado foram observadas na tensão de 30 kPa e com a linha lateral posicionada a 10 cm de profundidade. A profundidade de insta... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
54

Influência do ângulo entre a crista óssea e a superfície radicular na profundidade do sulco gengival clínico / Influence of the angle between the bone crest and root surfaces in the depth of the clinical gingival sulcus

Alvarez, Carlos Federico Franco 26 October 2011 (has links)
Foi desenvolvido projeto de pesquisa clínica e radiográfica para avaliar a influência do ângulo formado entre a superfície dental e a crista óssea na determinação da profundidade de sondagem do sulco gengival e complementarmente no comportamento da margem gengival por vestibular de dentes molares inferiores inclinados para mesial. Para tanto foram incluídos 30 sítios mesiais e 30 distais no grupo teste, com igual número de sítios controles de molares inferiores com inclinação normal. Nos dentes que forneceram esses sítios também foi feita a determinação da profundidade do sulco gengival na região vestibular central do dente, identificando-se a qualidade e quantidade de gengiva ceratinizada, respectivamente pela metodologia de Kan et al. (2010) e pela mensuração com sonda periodontal da distância da margem gengival à junção mucogengival. Foram incluídos pacientes periodontal e sistemicamente saudáveis, excluindo-se pacientes que tivessem sido submetidos a procedimentos ósseos regenerativos prévios nas áreas de interesse, diabéticos relutantes ao controle médico, usuários de drogas e/ou álcool, portadores de alterações sistêmicas que interfiram no metabolismo ósseo (como por exemplo, osteoporose e hiperparatireoidismo). Os exames foram realizados por examinador competente, devidamente calibrado. Para análise radiográfica as imagens foram transferidas para o computador, realizando-se as mensurações dos ângulos interessados com o programa de computador MB-Ruler Pro (MB-Software solutions). A análise estatística foi realizada no programa GraphPad Prism versão 5.03 para Windows (GraphPad, Usa). Os resultados obtidos em linhas gerais mostraram que houve influência significativa do ângulo entre a superfície dental e a crista óssea (p > 0,0001) na determinação do sulco gengival proximal em áreas de dentes inclinados, porém não há essa influência na profundidade de sondagem do sulco gengival por vestibular para áreas com qualidade e quantidade de gengiva comparáveis ao controle (p=0,08). A despeito desses resultados, não se encontrou correlação definida entre nenhum dos parâmetros de interesse analisados. Dentro dos limites do estudo os resultados também evidenciaram que, embora possam ocorrer variações desses parâmetros, a saúde periodontal pode ser mantida pelo indivíduo nas condições analisadas. / A clinical and radiographic research project was developed to assess the influence of the angle formed between the tooth surface and the alveolar bone crest in determining the probing depth of the gingival sulcus and complementary also to evaluate the behavior of the buccal gingival margin of mesially inclined molars. Therefore, 30 mesial and 30 distal sites of inclined lower molars were included in the test group, with an equal number of sites of lower molars with normal inclination in the control group. In addition in all the teeth of both test and control groups the depth of the clinical gingival sulcus at the central buccal region of the tooth was assessed by measuring with a periodontal probe, identifying the quality of the keratinized gingiva through the methodology of Kan et al. (2010) and determining the width of keratinized gingiva by measuring the distance from the free gingival margin to the mucogingival junction. The study was done in systemic and periodontally healthy individuals, excluding patients who had undergone bone-regenerative procedures in the areas of interest, diabetics reluctant to medical control, alcohol and / or drug users, and individuals suffering from systemic conditions that might interfere with bone metabolism (like osteoporosis and hyperparathyroidism). The examinations were performed by a competent and properly calibrated examiner. The radiographic images were then transferred to a computer in order to analyze the measurements of the involved angles with the computer program MB-Ruler Pro (MB-Software solutions). Statistical analysis was performed using GraphPad Prism version 5.03 for Windows (GraphPad, Usa). The results in general showed that there was significant influence of the angle between the tooth surface and the alveolar bone crest on the depth of the gingival sulcus in proximal areas of inclined teeth (p > 0,0001), but there was no such influence in the probing depth of the buccal gingival sulcus of these inclined molars provided that the quality and quantity of gingiva were similar to controls comprised by molars with normal inclination (p=0,08). Despite this significance, there was no definite correlation between any of the analyzed parameters of interest. The results also showed that, although there may be variations of these parameters, within the limits of this study the conditions of periodontal health can be maintained by the individual.
55

Resistência ao cisalhamento de sistemas adesivos autocondicionantes e de condicionamento total aplicados em dentina, em profundidades diferentes / Shear bond of different self etch and total etch adhesive systems applied in different dentin depth

Rosa, Ana Carolina Maito Villela 12 August 2009 (has links)
Objetivos: O propósito deste estudo foi o de avaliar, quanto à resistência ao cisalhamento, o comportamento de quatro sistemas adesivos, Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE e Self Etch Bond em função das faces vestibulares e linguais e da profundidade da dentina. Material e Método: Quarenta terceiros molares extraídos tiveram suas raízes removidas e as coroas seccionadas no sentido mésio-distal. As faces vestibulares e linguais foram incluídas em anel de PVC/resina acrílica e divididas em grupos, um vestibular e um lingual para cada adesivo selecionado. Para se avaliar as diferentes profundidades de dentina, os mesmos corpos-de-prova preparados para a avaliação da resistência adesiva da camada superficial foram utilizados. Os espécimes foram então identificados e desgastados, posterior e seqüencialmente, para as profundidades de 0,5, 1,0, 1,5, 2,0mm. Cada profundidade foi avaliada por meio do método de cisalhamento ISO TR 11405, usando uma máquina universal de testes (EMIC-2000), regulada a 0,5mm/minuto e célula de carga de 200 Kgf. Os resultados foram submetidos à análise estatística de variância (Testes ANOVA, Tukey e Scheffé). Resultados: Houve diferença estatística significante (p<0,01) para dois fatores de variação (adesivo e profundidade) e para a interação adesivo x profundidade (p<0,01). O adesivo Adper Single Bond 2, apresentou maiores valores em relação aos outros três adesivos. O adesivo Adper Prompt L-Pop, autocondicionante teve valores maiores que o adesivo autocondicionante e também o de condicionamento total da Vigodent. Enquanto que, o Self Etch Bond, apresentou os menores valores de resistência adesiva ao cisalhamento em relação aos demais sistemas adesivos. Conclusões: Baseado nestes achados pode-se concluir que a resistência ao cisalhamento da dentina é dependente do sistema adesivo utilizado, da profundidade do substrato e da interação entre estes dois fatores. / Objective: The aim of this study was to evaluate the dentin shear bond strength of four adhesive systems: Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond related to buccal and lingual surfaces and dentin depth. Material and Methods: Fourty extracted third molars had the roots removed and the crowns bisected on the mesio-distal direction. The buccal and lingual surfaces were included in PVC/acrylic resin ring and divided into buccal and lingual groups to each selected adhesives. The same specimens prepared to evaluation of superficial shear resistance were used in order to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0mm. Each depth was evaluated by ISO TR 11405, using an EMIC-2000 machine regulated at 0.5mm/min and 200 Kgf of cell load. The results were submitted to statistical analysis (ANOVA, Tukey and Scheffé Tests). Results: Data showed statistical differences to adhesive and depth variation factors (p<0,01) and to adhesive/depth (p<0,01) interaction. The Adper Single Bond 2 showed highest mean values of shear bond strength. The Adper Prompt L-Pop, a self-etching adhesive, showed higher mean values compared to Magic Bond DE and Self Etch Bond, a total and self etching adhesives, respectivelly. Conclusions: Based on these findings it can be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and the adhesive/depth interaction.
56

Determinação de grandezas dosimétricas de interesse em mamografia usando detectores termoluminescentes / Determination of dosimetric quantities of interest in Mammography using thermoluminescent detectors.

Mendoza, Raul Ernesto Camargo 10 February 2010 (has links)
Os órgãos de saúde internacionais e nacionais, como o Ministério da Saúde na portaria 453/98 da Vigilância Sanitária, exigem que a Dose de Entrada na Pele seja avaliada para cada equipamento mamográfico através da leitura de um sistema câmara de ionização-eletrómetro corrigida pelo fator de retroespalhamento. Ao não existir menção explícita na portaría de valores utilizáveis para o fator de retroespalhamento, este trabalho visa à determinação experimental do fator de retroespalhamento, através da utilização dos dosímetros termoluminescentes TLD-100. No estudo são verificadas as dependências geométricas e espectrais do fator de retroespalhamento, assim como do valor da Dose de Entrada na Pele, e da Dose em Profundidade, correspondentes com as técnicas radiográficas empregadas nos exames mamográficos convencionais de rotina. Foram avaliados feixes na faixa de 0,35 mmAl até 0,43 mmAl, tensões do tubo de 25kV, 28kV, 30kV, e 32kV, assim como os três tamanhos de campo disponíveis no Mamógrafo Senographe DMR utilizado, e distancias focofilme iguais a 56cm, 61cm e 66cm. Os resultados obtidos foram comparados com publicações existentes, as quais apresentam resultados obtidos através de Simulação Monte Carlo, câmaras de ionização, e dosímetros TLD-100. Os resultados obtidos neste trabalho permitem estabelecer e discutir as dependências das grandezas dosimétricas estudadas com a Camada Semi-Redutora, tensão do tubo, combinação ânodo-filtro, tamanho de campo, distância foco-filme e espessura da mama. / National and international health organizations such as the Brazilian Ministry of Health, through its Secretary of Health Surveillance establishes in the publication Nº 453/98 that in all mammographic equipments must be evaluated the entrance-skin dose through the readings of an ionization chamber-electrometer system corrected by the backscatter factor, among others factors. Nevertheless, there is no explicit mention for useful values of backscatter factor in this document; the main aim of this work is the experimental determination of backscatter factor through the use of TLD-100 dosimeters. In this study, the geometric and spectral dependencies of the backscatter factor, entrance-skin dose and the in-depth dose were evaluated, corresponding to the most radiographic techniques employed in conventional mammographic procedures, i.e., beam qualities in the range of 0.35 mmAl to 0.43 mmAl, tube voltages from 25kV to 32kV, focus-film distances from 56cm to 66cm, and three field sizes were evaluated. Our results were compared with those previously published obtained through Monte Carlo simulation, ionization chambers and TLD dosimeters. The results obtained in this work allow studying the dependency of the mentioned dosimetric quantities with the half-value layer, tube voltage, anode-filter combination, field size, focusfilm distance and breasting thickness of the breast.
57

Resistência ao cisalhamento de sistemas adesivos autocondicionantes e de condicionamento total aplicados em dentina, em profundidades diferentes / Shear bond of different self etch and total etch adhesive systems applied in different dentin depth

Ana Carolina Maito Villela Rosa 12 August 2009 (has links)
Objetivos: O propósito deste estudo foi o de avaliar, quanto à resistência ao cisalhamento, o comportamento de quatro sistemas adesivos, Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE e Self Etch Bond em função das faces vestibulares e linguais e da profundidade da dentina. Material e Método: Quarenta terceiros molares extraídos tiveram suas raízes removidas e as coroas seccionadas no sentido mésio-distal. As faces vestibulares e linguais foram incluídas em anel de PVC/resina acrílica e divididas em grupos, um vestibular e um lingual para cada adesivo selecionado. Para se avaliar as diferentes profundidades de dentina, os mesmos corpos-de-prova preparados para a avaliação da resistência adesiva da camada superficial foram utilizados. Os espécimes foram então identificados e desgastados, posterior e seqüencialmente, para as profundidades de 0,5, 1,0, 1,5, 2,0mm. Cada profundidade foi avaliada por meio do método de cisalhamento ISO TR 11405, usando uma máquina universal de testes (EMIC-2000), regulada a 0,5mm/minuto e célula de carga de 200 Kgf. Os resultados foram submetidos à análise estatística de variância (Testes ANOVA, Tukey e Scheffé). Resultados: Houve diferença estatística significante (p<0,01) para dois fatores de variação (adesivo e profundidade) e para a interação adesivo x profundidade (p<0,01). O adesivo Adper Single Bond 2, apresentou maiores valores em relação aos outros três adesivos. O adesivo Adper Prompt L-Pop, autocondicionante teve valores maiores que o adesivo autocondicionante e também o de condicionamento total da Vigodent. Enquanto que, o Self Etch Bond, apresentou os menores valores de resistência adesiva ao cisalhamento em relação aos demais sistemas adesivos. Conclusões: Baseado nestes achados pode-se concluir que a resistência ao cisalhamento da dentina é dependente do sistema adesivo utilizado, da profundidade do substrato e da interação entre estes dois fatores. / Objective: The aim of this study was to evaluate the dentin shear bond strength of four adhesive systems: Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond related to buccal and lingual surfaces and dentin depth. Material and Methods: Fourty extracted third molars had the roots removed and the crowns bisected on the mesio-distal direction. The buccal and lingual surfaces were included in PVC/acrylic resin ring and divided into buccal and lingual groups to each selected adhesives. The same specimens prepared to evaluation of superficial shear resistance were used in order to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0mm. Each depth was evaluated by ISO TR 11405, using an EMIC-2000 machine regulated at 0.5mm/min and 200 Kgf of cell load. The results were submitted to statistical analysis (ANOVA, Tukey and Scheffé Tests). Results: Data showed statistical differences to adhesive and depth variation factors (p<0,01) and to adhesive/depth (p<0,01) interaction. The Adper Single Bond 2 showed highest mean values of shear bond strength. The Adper Prompt L-Pop, a self-etching adhesive, showed higher mean values compared to Magic Bond DE and Self Etch Bond, a total and self etching adhesives, respectivelly. Conclusions: Based on these findings it can be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and the adhesive/depth interaction.
58

Extensão do palato mole e profundidade da nasofaringe na fissura transforame unilateral operada / Width of the soft palate and depth of the nasopharynx in transforame unilateral cleft [Doctoral Thesis]

Souza, Olívia Mesquita Vieira de 18 October 2013 (has links)
Introdução: Ao consideramos que o crescimento craniofacial no indivíduo com fissura labiopalatina (FLP) é influenciado pela própria fissura e pelas cirurgias para sua correção, surgem questionamentos importantes quanto ao uso de medidas normativas obtidas com indivíduos que não apresentaram FLP para interpretar achados na fissura. Em 1957, Subtelny publicou medidas da extensão (ETV) e espessura (EPV) do palato mole e da profundidade da velofaringe (PN) e seus achados são usados como normas de referência para interpretar medidas na FLP. As normas foram calculadas a partir de telerradiografias obtidas ao longo de 18 anos em 30 norte-americanos sem fissura. No gerenciamento da FLP medidas das estruturas e espaços velofaríngeos podem contribuir para o diagnóstico da disfunção velofaríngea e documentação sistemática de resultados do tratamento. Objetivo: O objetivo principal deste estudo foi estabelecer ETV, EPV, e PNF na FLP operada e fala normal. Metodologia: As medidas foram determinadas a partir de telerradiografia em norma lateral para sujeitos com fissura transforame incisivo unilateral operada (FTIUO) que obtiveram fala normal após palatoplastia. A razão entre a medida de profundidade da nasofaringe e extensão velar (RPE) também foi estabelecida e os achados foram comparados com os dados de Subtelny. Os prontuários dos pacientes estudados foram consultados para confirmar fala normal no dia da radiográfica. As medidas foram realizadas com o programa Dolphin Imaging, versão 11.0, com análise de Arnett-Gunson FAB. Medidas da média e desvio padrão foram usadas para descrição dos achados com apresentação em tabelas e gráficos. O teste t não pareado foi usado para testar a hipótese de existência de diferença estatisticamente significante entre as medidas deste estudo e as normas de Subtelny, considerando-se estatisticamente significantes os resultados onde p < 0,05. Resultados: Foi analisado um total de 260 telerradiografias, sendo que 120 do gênero feminino e 140 masculino, com idades entre 5 e 14 anos. Comparando-se as medidas com os dados de Subtelny, observou-se: a) diferenças significantes para a medida ETV dos 05 aos 11 anos e 13 anos, sugerindo que o palato de pacientes com FTIUO com fala normal é mais curto do que de Subtelny na maioria das idades estudadas; b) diferenças significantes para a medida EPV nas idades de 5, 11, 12 e 14 anos, sugerindo que o palato de pacientes com FTIUO com fala normal é mais espesso do que de Subtelny, em algumas das idades estudadas; c) diferenças significantes para a medida PNF dos 05 aos 13 anos, sugerindo que espaço nasofaríngeo em pacientes com FTIUO com fala normal é mais estreito do que de Subtelny na maioria das idades estudadas; e d) diferença estatisticamente significante na RPE para as idades de 05 a 09 anos e 12 e 13 anos, sugerindo potencial para fechamento velofaríngeo e, portanto, corroborando o critério de fala normal. Discussão: Este estudo revelou medidas de EPV, ETV, e PNF para indivíduos com FTIUO significantemente diferentes daquelas propostas por Subtelny. Mesmo na presença de palato mais curto os pacientes estudados apresentavam fala normal sugerindo fechamento velofaríngeo adequado. Este achado pode ser decorrente de aumento de tecido linfático na população com FTIUO, o que foi confirmado com a medida de PNF que indica nasofaringe significantemente mais estreita na população estudada. O palato mole neste estudo foi muito mais espesso nos pacientes com fissura o que pode ser resultado da cicatrização velar ou uso de procedimento cirúrgico envolvendo a sobreposição de músculos o que explica aumento de tecido mole na área estudada. Conclusão: Como muitos dos achados deste estudo foram significantemente diferente das normas estabelecidas por Subtelny, sugere-se que as medidas propostas em 1957 não são representativas da população com FTIUO e fala normal. Propõe-se a importância de estabelecerem-se medidas normativas das estruturas e espaços velofaríngeos para populações específicas, de forma a contribuir para documentação de resultados do tratamento e complementar o processo diagnóstico e a definição da conduta para tratar a DVF. Telerradiografias são obtidas sistematicamente para os pacientes com FLP ao redor dos 8 anos na maioria dos centros craniofaciais ao redor do mundo, as medidas estudadas podem (e deveriam) ser obtidas para todos os pacientes (com e sem fala normal) nesta idade. / Introduction: Considering that craniofacial growth in individuals with cleft lip and palate (CLP) is affected by the cleft and the surgeries to correct the anomaly, important questions can be made regarding interpreting clinical findings for individuals with CLP using normative data obtained with a population without CLP. In 1957, Subtelny published data about the length (LSP) and width (WSP) of the soft palate and depth of the nasopharynx (DNP) and his findings are used until today as reference for interpretation of measures of velopharyngeal structure and space in the population with CLP. Subtelnys norms were calculated using cephalometric X-rays (CEPH) obtained during the first 18 years of life of 30 North-American speakers without CLP. While managing CLP measures of velopharyngeal structures and spaces can contribute in the diagnosis of velopharyngeal dysfunction (VPD) and systematic documentation of treatment outcome. Objective: The primary objective of this study was to establish LSP, WSP, and DNP in individuals with CLP and normal speech. Methodology: The measures of LSP, WSP and DNP were determined using CEPHs obtained from a group of individuals with operated unilateral cleft lip and palate (OUCLP) and normal speech after primary palatoplasty. The ratio between the measures of DNP and LSP (RDL) was also calculated and all findings were compared to Subtelnys. All CEPHs in a UCLPs data bank were considered for this study. Patients charts were reviewed to confirm normal speech. The measures were obtained using Arnett and Gunson FAB cephalometric analysis in Dolphin Imaging program (version 11.0). Mean and standard deviation measures were used to describe the findings which are presented in tables and graphs. Students t-test (unpaired) was used to test the hypothesis that this studys findings were significantly different than Subtelnys, with significance established at p<0.05. Results: A total of 260 CEPHs were studied, 120 from females and 140 from males between 5 and 13 years of age. Comparing this studys measures to Subtelnys we observed: a) significant difference in LSP between 5 and 11 years and 13 years, suggesting that the soft palate in individuals with OUCLP with normal speech is significantly shorten than Subtelnys for most ages studied; b) significant difference in WSP at 5, 11, 12 and 14 years of age, suggesting that the soft palate in individuals with OUCLP with normal speech is significantly thicker than the palates in Subtelnys for some age groups; c) significant difference in DNP between 5 and 13 years of age, suggesting that nasopharyngeal space in individuals with OUCLP with normal speech is significantly narrower than Subtelnys, for most ages studied; d) significant difference in RPE was found between 5 and 9 years and at 12 and 13 years of age suggesting potential for velopharyngeal closure and, therefore, corroborating criteria of normal speech. Discussion: This study revealed measures of LSP, WSP and DNP significantly different for individuals with OUCLP and normal speech when compared to Subtelnys norms for several age groups. Even though a much shorten soft palate was found (LSP), all patients studied presented with normal speech indicative of adequate velopharyngeal closure. This finding may be related to enlarged lymphatic tissue (adenoids) in the population with OUCLP and is supported in this study by reduced measures of DNP which revealed nasopharynx significantly narrower for the individuals with OUCLP when compared to the norms. The soft palate in this study was thicker which may be the result of velar scarring or the use of a surgical procedure involving muscle transpositioning during palatal repair which can explain more soft tissue in the area studied. Conclusion: Most findings for this study were significantly different than the reference norms established by Subtelny, suggesting that the norms, proposed in 1957 are not representative of population with OUCLP with normal speech. Establishing population specific normative data about size of velopharyngeal structures and spaces is important and can contribute adding an information about the outcome of cleft repair and also complement the diagnostic process supporting the identification of the best treatment for VPD. Since CEPH are systematically obtained for patients with CLP around 8 years of age in most craniofacial centers around the world, measures of LSP, WSP, DNP and RDL can (and should) be obtained for all patients(with and without normal speech) at this age.
59

Detecção de gestos manuais utilizando câmeras de profundidade / Detection of hand gestures using depth cameras

Prado Neto, Elias Ximenes do 28 May 2014 (has links)
É descrito o projeto de um sistema baseado em visão computacional, para o reconhecimento de poses manuais distintas, além da discriminação e rastreamento de seus membros. Entre os requisitos prioritários deste software estão a eficácia e a eficiência para essas tarefas, de forma a possibilitar o controle em tempo real de sistemas computacionais, por meio de gestos de mãos. Além desses fatores, a portabilidade para outros dispositivos e plataformas computacionais, e a possibilidade de extensão da quantidade de poses iniciais, também consiste em condições importantes para a sua funcionalidade. Essas características tendem a promover a popularização da interface proposta, possibilitando a sua aplicação para diversas finalidades e situações; contribuindo dessa forma para a difusão deste tipo de tecnologia e o desenvolvimento das áreas de interfaces gestuais e visão computacional. Vários métodos foram desenvolvidos e pesquisados com base na metodologia de extração de características, utilizando algoritmos de processamento de imagens, análise de vídeo, e visão computacional, além de softwares de aprendizado de máquina para classificação de imagens. Como dispositivo de captura, foi selecionada uma câmera de profundidade, visando obter informações auxiliares aos vários processos associados, reduzindo assim os custos computacionais inerentes e possibilitando a manipulação de sistemas eletrônicos em espaços virtuais tridimensionais. Por meio desse dispositivo, foram filmados alguns voluntários, realizando as poses manuais propostas, de forma a validar os algoritmos desenvolvidos e possibilitar o treinamento dos classificadores utilizados. Esse registro foi necessário, já que não foram encontradas bases de dados disponíveis contendo imagens com informações adequadas para os métodos pesquisados. Por fim, foi desenvolvido um conjunto de métodos capaz de atingir esses objetivos, através de sua combinação para adequação a diferentes dispositivos e tarefas, abrangendo assim todos os requisitos identificados inicialmente. Além do sistema implementado, a publicação da base de imagens de poses de mãos produzida também consiste em uma contribuição para as áreas do conhecimento associadas a este trabalho. Uma vez que as pesquisas realizadas indicam que esta base corresponde ao primeiro conjunto de dados disponibilizado, compatíveis com vários métodos de detecção de gestos manuais por visão computacional, acredita-se que esta venha a auxiliar ao desenvolvimento de softwares com finalidades semelhantes, além possibilitar uma comparação adequada entre o desempenho desses, por meio de sua utilização. / A project of a computer vision based system is described here, for the recognition of different kinds of hand poses, in addition to the discrimination and tracking of its members. Among the software requirements priority, were the efficiency and effectiveness in these tasks, in order to enable the real time control of computer systems by hand gestures. Besides these features, the portability to various devices and computational platforms, and the extension possibility of initial pose number, are also importants conditions for its functionality. Several methods have been developed and researched, based on the methodology of feature extraction, using image processing, video analysis, and computer vision algorithms; in addition to machine learning software for image classification. As capture device, was selected a depth camera, in order to obtain helper information to several associated processes, so reducing the computational costs involved, and enabling handling electronic systems in three-dimensional virtual spaces. Through this device, some volunteers were recorded, performing the proposed hand poses, in order to validate the developed algorithms and to allow the used classifiers training. This record was required, since available databases containing images with relevant information for researched methods was not found. Finally, were developed a set of methods able to achieve these goals, through its combination for adaptation to different devices and tasks, thus covering all requirements initially identified. Besides the developed system, the publication of the hand poses image database produced, is also an contribution to the field of knowledge related with this work. Since the researches carried out indicated that this database is the first set of available data, compatible with different computer vision detection methods for hand gestures, it\'s believed that this will assist in developing software with similar purposes, besides permit a proper comparison of the performances, by means of its use.
60

Utilização de técnicas de GPGPU em sistema de vídeo-avatar. / Use of GPGPU techniques in a video-avatar system.

Tsuda, Fernando 01 December 2011 (has links)
Este trabalho apresenta os resultados da pesquisa e da aplicação de técnicas de GPGPU (General-Purpose computation on Graphics Processing Units) sobre o sistema de vídeo-avatar com realidade aumentada denominado AVMix. Com o aumento da demanda por gráficos tridimensionais interativos em tempo real cada vez mais próximos da realidade, as GPUs (Graphics Processing Units) evoluíram até o estado atual, como um hardware com alto poder computacional que permite o processamento de algoritmos paralelamente sobre um grande volume de dados. Desta forma, É possível usar esta capacidade para aumentar o desempenho de algoritmos usados em diversas áreas, tais como a área de processamento de imagens e visão computacional. A partir das pesquisas de trabalhos semelhantes, definiu-se o uso da arquitetura CUDA (Computer Unified Device Architecture) da Nvidia, que facilita a implementação dos programas executados na GPU e ao mesmo tempo flexibiliza o seu uso, expondo ao programador o detalhamento de alguns recursos de hardware, como por exemplo a quantidade de processadores alocados e os diferentes tipos de memória. Após a reimplementação das rotinas críticas ao desempenho do sistema AVMix (mapa de profundidade, segmentação e interação), os resultados mostram viabilidade do uso da GPU para o processamento de algoritmos paralelos e a importância da avaliação do algoritmo a ser implementado em relação a complexidade do cálculo e ao volume de dados transferidos entre a GPU e a memória principal do computador. / This work presents the results of research and application of GPGPU (General-Purpose computation on Graphics Processing Units) techniques on the video-avatar system with augmented reality called AVMix. With increasing demand for interactive three-dimensional graphics rendered in real-time and closer to reality, GPUs (Graphics Processing Units) evolved to the present state as a high-powered computing hardware enabled to process parallel algorithms over a large data set. This way, it is possible to use this capability to increase the performance of algorithms used in several areas, such as image processing and computer vision. From the research of similar work, it is possible to define the use of CUDA (Computer Unified Device Architecture) from Nvidia, which facilitates the implementation of the programs that run on GPU and at the same time flexibilize its use, exposing to the programmer some details of hardware such as the number of processors allocated and the different types of memory. Following the reimplementation of critical performance routines of AVMix system (depth map, segmentation and interaction), the results show the viability of using the GPU to process parallel algorithms in this application and the importance of evaluating the algorithm to be implemented, considering the complexity of the calculation and the volume of data transferred between the GPU and the computer\'s main memory.

Page generated in 0.5375 seconds