• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 1
  • Tagged with
  • 54
  • 54
  • 36
  • 33
  • 16
  • 13
  • 12
  • 11
  • 11
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo comparativo in vivo da osseointegração em duas diferentes superfícies de implantes em liga TiAlV. Caracterização topográfica, análise de frequência por ressonância e histométrica /

Colombo, Luara Teixeira. January 2019 (has links)
Orientador: Francisley Ávila Souza / Banca: Idelmo Rabgel Garcia Junior / Banca: Osny Ferreira Júnior / Resumo: Objetivo: Avaliar o comportamento biológico do tecido ósseo ao redor de implantes manufaturados em liga Ti6Al-4V diante das superfícies modificadas por jateamento de óxido de alumínio seguido condicionamento ácido (SBAS) e a superfície usinada (MS). Material e Métodos: Dez coelhos receberam aleatoriamente 20 implantes de hexágono externo com dimensões de 4,0 mm de diâmetro e 10 mm de comprimento em suas tíbias direita e esquerda, sendo um implante de cada superfície em cada tíbia. Os implantes de ambos os grupos foram analisados através de microscopia eletrônica de varredura (MEV-EDX) e microscopia de força atômica (AFM). Discos com as mesmas superfícies foram submetidos à análise de rugosidade média (Ra) e secção transversal. Nos períodos de 3 e 6 semanas foi mensurado o coeficiente de estabilidade primária por meio da análise de frequência por ressonância (ISQ), seguido da eutanásia dos animais. As peças obtidas foram submetidas ao processamento de inclusão em resina fotopolimerizável e levadas ao micrótomo para corte calcificado. Foi mensurada em porcentagem a extensão linear de contato entre tecido ósseo mineralizado e implante (ELCOMI) e área óssea neoformada (AON). Os dados foram submetidos à análise de variância e ao teste t de Tukey. Resultados: MEV e AFM mostraram diferenças na topografia das superfícies. Os valores médios obtidos pelas análises de frequência por ressonância, Ra e secção transversal para SBAS foram estatisticamente superiores (p<0,05) quando comparad... (Resumo completo, clicar acesso eletrônico abaixo) / Objective: Evaluate the biological behavior of bone tissue around implants manufactured in Ti-6Al-4V alloy before surfaces modified by aluminum oxide blasting followed by acid etching (SBAS) and machined surface (MS).Material and Methods: Ten rabbits randomly received 20 external hexagon implants with dimensions of 4.0 mm in diameter and 10 mm in length on theirright and left tibiae, one implant of each surface on each tibia. The implants of both groups were analyzed by scanning electron microscopy (SEM-EDX) and atomic force microscopy (AFM). Disks withthe same surfaces were submitted to analysis of average roughness (Ra) and cross section. In the periods of 3 and 6 weeks, the primary stability coefficient was measured by means of resonance frequency analysis (ISQ), followed by euthanasia of the animals. The obtained pieces were submitted to the inclusion processing in photopolymerizable resin and taken to the microtome for cutting without decalcification. The bone interface contact (BIC) and neoformed bone area (NBA) was measured in percentage. Data were submitted to analysis of variance and Tukey t test. Results: SEM and AFM showed differences in surface topography. The mean values obtained by the resonance, Ra and cross sectionanalyzes for SBAS were statistically higher (p <0.05) when compared to MS. The mean values in percentage of BICfor SBAS were 69.65 and 71.56 respectively for 3 and 6 weeks, while for MS the mean values were 54.06and 55.99 respectively for the same periods. The mean values of NBAin the SBAS group were 69.86 and 79.59 for the 3 and 6 week periods, while forMS the mean values were 59.59and 74.32, respectively, in the same groups. There were statistically superior differences (p <0.05) in SBAS implants for BICin the 3 and 6 week periods and AON in the 3 week period. Conclusion: The surface modification of the SBAS implants providedchanges... (Complete abstract electronic access below) / Mestre
22

Estudo da osseointegração de implantes de liga Ti30Ta instalados sem estabilidade primária. Influência da associação adesivo fibrínico/ácido tranexâmico e da superfície bioativa /

Wada, Cristiane Mayumi. January 2016 (has links)
Orientador: Maria Cristina Rosifini Alves Rezende / Banca: Carlos Roberto Grandini / Banca: Claudia Eliana Bruno Marino / Resumo: Quando implantes de titânio são instalados imediatamente após a extração dentária podem ocorrer ancoragem primária diminuída e retardo e/ou deficiência do processo de osseointegração. Isto se dá em razão da ampla interface entre as paredes circundantes do alvéolo e a superfície do implante. Evidências científicas demonstram que a resposta dos biomateriais quando inseridos num organismo vivo não depende apenas da sua composição, mas, sobretudo de sua superfície. Particularmente para os implantes dentários, o uso de ligas, o processo de usinagem e os tratamentos superficiais irão determinar características essenciais no desempenho clínico desses dispositivos. A liga Ti30Ta é altamente biocompatível, apresenta boa combinação de elevada resistência e baixo módulo de elasticidade, demonstrando excelente indicação para uso biomédico. O propósito deste trabalho foi avaliar histomorfometricamente em ratos o reparo ósseo ao redor de implantes de liga Ti30Ta com supertfície bioativa (tratamento hidrotérmico/biomimético) e associados à adesivo fibrínico/ácido tranexâmico. Foram confeccionados 32 implantes de Titânio CP Grau 4 (Grupo A/Ticp) e 32 implantes da liga Ti30Ta (Grupo B/Ti30Ta), os quais foram divididos em grupos com 8 implantes cada: GA1(Ticp), GA2(Ticp/ácido fibrínico/ácido tranexâmico), GA3(Ticp/superfície bioativa), GA4(Ticp/ Superfície Bioativa/Adesivo Fibrínico Ácido Tranexâmico), GB1(Ti30Ta), GB2 (Ti30Ta/ ácido fibrínico/ácido tranexâmico), GB3 (Ti30Ta/ sup... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: When implants are installed immediately after tooth extraction it may occur decreased primary anchor and delay and/or deficiency of osseointegration process. This occur because of the large interface between the sorrounding walls of the socket and the surface of the implant. Scientific evidence shows that the response of biomaterials when inserted into a living organism depends not only on its composition, but mainly its surface. Particularly for dental implants, use of alloys, the process of machining and surface treatments will determine the essential clinical performance characteristics of these devices. The Ti-30T alloy is highly biocompatible and exhibits good combination of high strengh and low modulus of elasticity, demonstrating excellent indication for biomedical use. The purpose of this study was to evaluate histomorphometrically in rats bone healing around Ti-30Ta alloy implants with bioactive surface (hydrothermal/biomimetic treatment) and associated with fibrin gle/tranexamic acid. They were made 32 CP titanium Grade 4 (Group A/Ticp) and 32 implants of Ti-30Ta alloy (Group B/Ti-30Ta). These groups (n=8) were divided into groups . GA1 9Ticp), GA2 (Ticp/fibrin glue/tranexamic acid), GA3 (Ticp/bioactive surface) and GA4 (Ticp/bioactive surface/ fibrin glue/tranexamic acid) and GB1 (Ti-30Ta), GB2 (Ti-30Ta/ fibrin glue/ tranexamic acid), GB3 (Ti-30Ta bioactive surface) and GB4 (Ti-30Ta /bioactive surface/fibrin glue/tranexamic acid). The implants of Group A and B were identified, packed individually and sterilized by gamma irradiation and implanted in the righ tibia of 64 male rats. The animal were euthanized at 60 days postoperatively. The pieces were processed in MMA (Stevenel's blue/red Alizarin S) for histomorphometric analysis. The results showed statistically significant differences to both the contact percentage of bone / implant to bone as percentage area within the confines of the threads between the groups. Thus, superior... / Mestre
23

Estudo de implantes de Ticp com superfícies modificadas por feixe de laser com e sem deposição química de apatitas: análises topográfica, biomecânica e histométrica em coelhos

Queiroz, Thallita Pereira [UNESP] 16 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-16Bitstream added on 2014-06-13T19:01:26Z : No. of bitstreams: 1 queiroz_tp_dr_araca.pdf: 6726778 bytes, checksum: 065d55c84b04f648183adf1b94784bd6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O sucesso da reabilitação com implantes osseointegráveis é dependente de vários fatores, destacando-se as propriedades físico-químicas da superfície, que interferem nas respostas biológicas e conseqüente reparo ósseo da interface osso/implante. O propósito deste estudo foi avaliar as superfícies de implantes de titânio comercialmente puro (Ticp) modificadas por feixe de laser (SL) sem e com deposição de hidroxiapatita pelo método biomimético, sem (SHAST) e com tratamento térmico (SHACT), comparando-as com implantes de superfície modificada por tratamento ácido (SA) e com superfície usinada (SU), empregando-se análises topográfica, biomecânica e histométrica. Quarenta e cinco coelhos receberam 150 implantes, sendo 2 implantes de cada superfície por tíbia. Após 30, 60 e 90 dias, os animais foram submetidos à eutanásia e os implantes localizados superiormente foram expostos, removidos por torque-reverso para análise biomecânica e as superfícies foram analisadas topograficamente. O implante localizado mais inferiormente em cada tíbia foi removido com o tecido ósseo ao redor e processado para obtenção de cortes histológicos não-descalcificados para análise histométrica da extensão linear de contato osso/implante (ELCOI) e da área óssea (AO) entre as espiras da região cortical superior. Aos 30 e 60 dias, os grupos SL, SHAST, SHACT e SA apresentaram valores de torque-reverso estatisticamente superiores (p<0,05) ao torque de SU. Aos 30 dias, os grupos SHAST e SHACT foram estatisticamente superiores ao grupo SA e o grupo SHAST foi superior ao SL. Aos 90 dias a diferença foi observada somente entre SHAST e SU. A análise topográfica revelou diferença estatística significante (p<0,05) entre a rugosidade de SL, SHAST e SHABT quando comparadas com SA e SU. A análise histométrica da ELCOI mostrou... / The success of rehabilitation with dental implants is dependent on several factors, highlighting the physical and chemical properties of the implant surface, which interfere with the biological responses and subsequent bone repair of bone-implant interface. The purpose of this study was to evaluate the surfaces of implants of commercially pure titanium (cp Ti) modified by laser beam (LS) with and without hydroxyapatite deposition by the biomimetic method, without (HAB) and with thermal treatment (HABT) comparing them with implants surface modified by treatment with acid (AS) and machined surface (MS), employing topographical, biomechanics and histometric analysis. Forty-five rabbits received 150 implants (2 implants of each surface in each tibia). After 30, 60 and 90 days, the animals were euthanized and the implants superiorly located were exposed, removed by removal torque for biomechanical analysis and the surfaces were examined topographically. The implant located more inferiorly in each tibia was removed with the bone tissue around and it was processed to obtain non-decalcified histological sections for histometric analysis of the percentage of bone-implant contact (BIC) and bone area (BA) between the threads of higher cortical. At 30 and 60 days, the groups LS, HAB, HABT and AS obtained removal torque values statistically superior (p <0.05) than the removal torque of MS. At 30 days, the HAB and HABT groups were statistically superior to the AS group and HAB was higher than LS. At 90 days, HAB was statistically significant different from MS. The topographical analysis showed statistically significant difference (p <0.05) between the roughness of LS, HAB and HABT when compared with AS and MS. The histometric analysis of BIC showed that LS, HAB and HABT were statistically superior to the AS and MS, in three... (Complete abstract click electronic access below)
24

Avaliação das propriedades de superfície de ligas de titânio anodizadas com elementos bioativos /

Reis, Bárbara Araújo dos January 2018 (has links)
Orientador: Luis Geraldo Vaz / Resumo: O titânio comercialmente puro e suas ligas vêm sendo amplamente utilizados para confecção de implantes dentários e ortopédicos devido à adequada resistência mecânica, resistência à corrosão e biocompatibilidade. Entretanto, para aprimorar o tratamento com o uso de implantes, novas ligas e novos tratamentos de superfície vêm sendo pesquisados. A técnica de funcionalização de superfície, baseada em processos úmidos, é amplamente utilizada para desenvolver superfícies a base de óxido de titânio que induza e aumente a osseocondução. Assim, o objetivo deste estudo foi caracterizar a superfície de discos de Ti-6Al-4V e Ti-35Nb-7Zr-Ta após anodização para funcionalização com íons cálcio (Ca) e fósforo (P) ou fluoreto e dopagem com magnésio (Mg++) em diferentes condições experimentais, sendo a liga Ti-6Al-4V utilizada como controle. As ligas foram analisadas antes e após a realização dos tratamentos (anodização e dopagem), para avaliação das propriedades de superfície- composição química, energia livre de superfície (ELS), morfologia/ topografia e rugosidade média (Ra). Para interpretação dos resultados referentes a ELS e Ra foi aplicado teste estatístico por um operador cego, de acordo com o tipo de distribuição e nível de significância de 5%. As micrografias obtidas demonstraram que a anodização com Ca e P propiciou a formação de superfícies com poros interconectados e a anodização com ácido fluorídrico (HF) resultou em superfícies com formação de nanotubos. Todos íons adicionados ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Commercially pure titanium and its alloys have been widely used in the manufacture of dental and orthopedic implants due to adequate mechanical strength, corrosion resistance and biocompatibility. However, to improve the treatment with the use of implants to optimize osseointegration, new alloys and new surface treatments have been researched. The surface functionalization technique, based on wet processes, is widely used to develop titanium oxide based surfaces that induce and increase osseoconduction. The aim of this study was to characterize the surface of Ti-6Al-4V and Ti-35Nb-7Zr-Ta discs after anodization for functionalization with calcium ions (Ca) and phosphorus (P) or fluoride and doping with magnesium (Mg ++) in different experimental conditions. The Ti-6Al-4V alloy was used as a control. The alloys were analyzed before and after the treatments (anodization and doping), to evaluate the surface properties - chemical composition, surface free energy (ELS), morphology / topography and medium roughness (Ra). For the interpretation of the ELS and Ra results, a statistical test was applied according to the type of distribution and level of significance of 5%. The obtained micrographs showed that the anodization with Ca and P allowed the formation of surfaces with interconnected pores and the anodization with hydrofluoric acid resulted in surfaces with formation of nanotubes. All ions added to the electrolytes were incorporated into the samples, detected by ELS. The roughn... (Complete abstract click electronic access below) / Mestre
25

Influência do selante de superfície em propriedades físicas e mecânicas de resinas compostas submetidas a envelhecimentos artificiais

Catelan, Anderson [UNESP] January 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 catelan_a_me_araca.pdf: 509697 bytes, checksum: 775138bff151daa12592bcd4fc83894b (MD5) / O propósito deste estudo foi avaliar a influência do selante de superfície (Biscover LV, Bisco) na microdureza Knoop, rugosidade de superfície e alteração de cor de resinas compostas microhíbridas e nanoparticulada submetidas a envelhecimentos artificiais. Cem espécimes foram confeccionados para cada resina composta, Supreme XT (3M/Espe), Vit-l-escence (Ultradent) e Opallis (FGM). Após 24h, as superfícies das amostras foram polidas e o selante foi aplicado em 50 amostras de cada compósito. A rugosidade de superfície (Ra) foi determinada com um perfilômetro (SJ-400, Mitutoyo) e cut-off de 0,25mm; a microdureza Knoop foi avaliada em um microdurômetro (HMV-2000, Shimadzu), com carga de 50g durante 15s; e a análise cromática inicial foi avaliada de acordo com o sistema CIE L*a*b* em espectrofotômetro de reflexão (UV-2450, Shimadzu). Após as avaliações iniciais, 10 espécimes de cada grupo foram envelhecidos durante 252h em câmara de envelhecimento acelerado de UV (EQUV, Equilam) ou imersos por 4 semanas em uma das três soluções corantes (refrigerante de cola, suco de laranja ou vinho tinto) ou água destilada como controle. Após os envelhecimentos, as propriedades testadas foram re-avaliadas. Os dados de microdureza, rugosidade, alteração de cor foram analisados pela ANOVA e teste de Fischer (α=0,05). Os envelhecimentos artificiais causaram mudanças de cor em todos os grupos e diminuíram os valores de microdureza para todos os materiais, exceto para os compósitos Vit-l-escence e Supreme XT selados, mas não alteraram os valores de rugosidade. O armazenamento em água destilada teve o menor efeito sobre a microdureza e os menores valores de ΔE comparado com os outros processos de envelhecimento (p<0,05). Os materiais selados apresentaram os menores valores de rugosidade e microdureza comparados aos compósitos não selados. Independente do material estudado... / The purpose of this study was to evaluate the influence of surface sealant (Biscover LV, Bisco) on the Knoop microhardness, surface roughness and color alteration of microhybrids and nanofilled composite resins submitted to artificial aging. One hundred specimens were made for each of the composite resins; Supreme XT (3M/Espe), Vit-l-escence (Ultradent) and Opallis (FGM). After 24h, the samples’ surfaces were polished and sealant was applied to 50 samples of each composite. The surface roughness (Ra) was determined using a perfilometer (SJ-400, Mitutoyo) and cut-off of 0.25mm; the Knoop microhardness was evaluated in a microdurometer (HMV-2000, Shimadzu), with 50g load during 15s; and the initial chromatic analysis was evaluated in accordance with CIE L*a*b* system in reflection spectrophotometer (UV-2450, Shimadzu). After the initial evaluations, 10 specimens of each group were aged during 252h in a UV-accelerated aging chamber (EQUV, Equilam) or immersed for 4 weeks in one of three staining solutions (cola soft drink, orange juice or red wine) or distilled water as control. After aging, the properties tested were reevaluated. The microhardness, surface roughness and color alteration data were analyzed by ANOVA and Fischer’s test (α=0.05). The artificial aging caused color changes in all the groups and decreased the microhardness values for all the materials, except for the Vit-l-escence and Supreme XT sealed composites, but had no effect on the roughness values. The storage in distilled water had the least effect on microhardness and resulted in the lowest values of TE compared with other aging processes (p<0.05). The sealed materials presented the lowest values of surface roughness and microhardness compared to the unsealed composites. Regardless of the material studied, the red wine solution demonstrated the highest level of staining (p<0.0001). Intermediate ΔE values were... (Complete abstract click electronic access below)
26

Modulação da expressão de miRNAs na diferenciação de osteoblastos em nanosuperfícies / Modulation of miRNA expression in osteoblast differentiation in nanosurfaces

Sartori, Elisa Mattias [UNESP] 27 April 2016 (has links)
Submitted by ELISA MATTIAS SARTORI null (elisamsartori@gmail.com) on 2016-06-23T20:05:53Z No. of bitstreams: 1 Elisa Mattias Sartori.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-06-27T18:58:23Z (GMT) No. of bitstreams: 1 sartori_em_dr_arafo.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5) / Made available in DSpace on 2016-06-27T18:58:23Z (GMT). No. of bitstreams: 1 sartori_em_dr_arafo.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5) Previous issue date: 2016-04-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: Este estudo teve como objetivo avaliar a modulação dos miRNAs que afetam o potencial osteogênico de CTMs em diferentes topografias de superfície de discos de vidro. Material e Métodos: Células tronco mesenquimais humanas foram plaqueadas nas diferentes superfícies e comparadas após 3, 7 e 14 dias para atividade de fosfatase alcalina, expressão de genes (Osteocalcina, Osteopontina, Sialo Proteína Óssea, Osterix, Runx2, BMP2 e ALP) e expressão de miRNAs. Microscopia eletrônica de varredura das superfícies com células foram obtidas para avaliação de adesão celular. Resultados: Atividade de fosfatase alcalina nas diferentes superfícies foi significantemente maior na superfície com nanotopografia. Do mesmo modo, a expressão de genes relacionados com osteoblastos foi mais elevada na superfície nano. Com 14 dias foi observado um aumento de 3.5 e 9 vezes para os genes Runx2 e Osterix, respectivamente. O gene da BMP2 e ALP também apresentou um aumento de 4 e 7 vezes comparado ao controle. Utilizando a tecnologia de sequenciamento de RNA (RNA-Seq) onde todos os RNAs existentes foram sequenciados, um total de 123 miRNAs com diferença de expressão foram encontrados comparando a superfície controle (dia 7) com a superfície nano (dia 14). 48 miRNAs apresentaram uma redução na expressão e 75 apresentaram um aumento de expressão. Alguns destes apresentaram marcadores para genes osteogênicos já identificados, tais como hsa-miR-135b-5p marcador para OCN, BSP, Runx2, CO15A1 e OSX, hsa-miR-122-5p marcador para OPN, hsa-miR-196a-5p marcador para BMP4, hsa-miR-26b-5p marcador para BMP2 e hsa-miR-148b-3p marcador para OPN. Conclusão: As superfícies com nanotopografia tem o potencial de melhorar a resposta de osseointegração de maneira a reduzir o tempo de osseointegração e também aumentar a produção de tecido ósseo ao redor dos implantes favorecendo assim áreas de qualidade óssea baixa. A utilização de miRNAs para alterar a resposta de diferenciação pode também ajudar a controlar o processo de osseointegração. / Purpose: This study aimed to evaluate the modulation of miRNAs that affect the osteogenic potential of MSCs in different surface topographies of glass disks. Material and Methods: Human mesenchymal stem cells (hMSCs) were plated on different surfaces of glass disks and compared at 3,7 and 14 days for alkaline phosphatase (ALP) activity, expression of genes (Osteocalcin, Osteopontin, Bone Sialo Protein, Osterix, Runx2, BMP2 and ALP) and expression of miRNAs. Scanning electron microscopy of surfaces with cells were obtained to analyse the attachment of cells. Results: ALP activity on different surfaces was significantly greater in the nanotopography surface. At day 14 there was a 3.5-fold and a 9-fold increase for Runx2 and Osterix gene, respectively. BMP2 and ALP also increased by 4- and 7-fold compared to control. Using RNA sequencing technology (RNA-Seq) a total of 123 miRNAs were found differently expressed comparing control (day 7) to nano surface (day 14). 48 miRNAs were downregulated and 75 were upregulated. Some of them regulated osteogenic genes such as hsa-miR-135b-5p that targets OCN, BSP, RUNX2, CO15A1 and OSX, hsa-miR-122-5p wich targets OPN, hsa-miR-196a-5p targets BMP4, hsa-miR-26b-5p that targets BMP2 and hsa-miR-148b-3p that targets OPN. Conclusion: Surfaces with nanotopography have the potential to improve osseointegration response in order to reduce the time of osseointegration and also increase the production of bone tissue around the implants improving low bone quality areas. The use of miRNAs to affect differentiation response may also help control the osseointegration process. / CAPES: BEX8187/14-2
27

Avaliação da resistência de união de reparos em resinas compostas convencionais e bulkfill /

Trevisan, Tamara Carolina. January 2016 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Weber Adad Ricci / banca: Gustavo Moncada / Resumo: Técnicas de reparos de restaurações vêm sendo amplamente utilizadas como um tratamento alternativo e conservador á substituição de restaurações defeituosas. O conhecimento do material a ser reparado e de um protocolo ideal, permitiria uma melhor relação biomecânica entre dente e material restaurador e possibilitaria técnicas eficazes e menos invasivas. O objetivo do presente estudo foi avaliar a resistência de união de reparo de diferentes resinas compostas, sob a influência de tratamentos de superfície, especialmente em relação a uma nova proposta comercial denominada de resinas "bulk fill". Para isso, foram confeccionados corpos de prova com diâmetro de 8mm por 4mm de altura, de diferentes classes de resinas compostas: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). Estes passaram por processo de envelhecimento artificial, realizado por meio de armazenamento em estufa com saliva artificial por 3 meses, sendo realizada a troca da saliva semanalmente, e finalizado com termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. Foram distribuídos aleatoriamente em três subgrupos, de acordo com o tratamento de superfície (n=5): G1- Controle- sem tratamento prévio; G2- Jateamento óxido alumínio; G3- Jateamento óxido de sílica. Após a aplicação dos respectivos tratamentos de superfície, cada espécime foi reparado com resina composta Z100 em incrementos de aproximadamente 2mm e fotopolimerizado em um aparelho de fotopolimerização convencion... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
28

Estudo comparativo da interação celular entre quatro tipos de implantes dentários / Comparative study of cellular interactions between four types of dental implants

Fabiana Ferreira Alves 26 February 2015 (has links)
O tratamento de superfície dos implantes dentários é um critério importante para a osseointegração. Considerando a variedade de modificações das superfícies encontradas, estas podem acelerar ou melhorar o processo de osseointegração. Para tanto foram estudadas as características da composição química e a rugosidade, a partir das quais foram encontradas diferentes respostas celulares em estudos comparativos in vitro. O objetivo deste estudo foi comparar a adesão e o crescimento dos OSTEO-1 em implantes dentários com diferentes tratamentos de superfície. Foram utilizados quatro tipos de implantes dentários comercialmente disponíveis, com os seguintes tratamentos de superfície: (A) jateamento e condicionamento ácido com revestimento de fosfato e cálcio (CaP); (B) duplo condicionamento ácido; (C) condicionamento ácido; (D) oxidação anódica. Os implantes de mesmo tamanho foram fixados com dispositivo biocompatível no fundo dos poços das placas de cultura de 12 poços e cobertas com meio de cultura de células. Os OSTEO-1 foram colocados no corpo do implante. Nos períodos de 24, 48 e 72 horas mais tarde, as culturas foram submetidas ao ensaio de redução de MTT para avaliar a viabilidade celular. Os dados foram utilizados para analisar a adesão celular (24h) e para obter as curvas de crescimento das células (24, 48 e 72h). Os experimentos foram realizados em triplicata. Os dados foram comparados por ANOVA, complementado pelo teste de Tukey (p <0,05). Os OSTEO-1 aderiram ao corpo de todos os tipos de implantes testados. A maior taxa de crescimento celular foi observada em culturas semeadas sobre tratamento de superfície A. O menor crescimento celular foi apresentado por culturas semeadas no tratamento de superfície D (p <0,05). Com base nesta investigação in vitro é possível concluir que todos os implantes dentários testados, independentemente do tratamento de superfície, não são citotóxicos para os OSTEO-1. No entanto, as características físico-químicas do tipo de tratamento de superfície dos implantes dentários influencia o crescimento celular. A superfície A pareceu ter o comportamento mais compatível com os OSTEO-1, uma vez que promoveu mais crescimento celular. / The surface treatment of dental implants is a major feature for osseointegration. The variety of surface modifications found may be speed up or enhance the osseointegration process. In much was studied the chemical composition and characteristics of roughness, from which found different cellular responses in comparative studies in vitro.The aim of this study was to compare the adhesion and growth of osteoblast-like cells in response to dental implants characterized by different superficial treatments. Four types of dental implants with different superficial treatments were used. The commercially available implants presented the following superficial characteristics: (A) sandblasted with acid-etched and calcium phosphates (CaP) coating; (B) double acid-etched; (C) anodized, or (D) acid-etched. The implants of the same size (n= 3 per group/experimental time) were fixed with a biocompatible device on the bottom of the wells of 12 wells cell culture plates and covered with cell culture medium. Osteoblast-like cells (Osteo 1 cell line) were plated on the top of the implants (5x104 cells/implant). Twenty-four, 48 and 72 hours later, the cultures were submitted to the MTT reduction assay to assess cell viabilities. Data was used for analyze cell adhesion (24 h) and to obtain cell growth curves ( 24, 48 and 72 h). The experiments were done in triplicate. Data were compared by ANOVA complemented by the Tukey\'s test (p<0.05). Osteoblast-like cells adhered on the top of all types of implants tested. The highest cell growth was observed in cultures plated on the top of sandblasted with acid-etched and CaP coating surfaces. The smallest cell growth was presented by cultures plated on double acid-etched surfaces (p < 0.05). Based on this in vitro investigation, it is possible to conclude that all dental implants tested irrespective to the surface treatment, are non-cytotoxic for osteoblast-like cells. However, the physicochemical chacteristics of the type of dental implants surface treatment influences the cell growth. In fact, the surface treated by sandblasting with acid-etched and CaP coating seemed to the most compatible with osteoblast-like cell biology, once it promoted the highest cell growth.
29

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Ricardo Sgura 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.
30

Estudo das características físico-químicas e biológicas pela adesão de osteoblastos em superfícies de titânio modificadas pela nitretação em plasma / Study of physical-chemical and osteoblast adhesion characteristics of titanium surfaces modified by plasma nitriding

José Sandro Pereira da Silva 27 January 2009 (has links)
INTRODUÇÃO: Superfícies de titânio modificadas por diferentes métodos foram estudadas com base nos parâmetros físicos e químicos de caracterização superficial e sua influência no comportamento de células pré-osteoblásticas (MC3T3) in vitro. MÉTODOS: Discos de titânio comercialmente puro grau II foram submetidos a três métodos de modificação de superfície (polimento, nitretados em plasma em configuração planar e gaiola catódica). As diferentes superfícies foram caracterizadas para observar o efeito do processamento na estrutura da camada superficial, na rugosidade e molhabilidade. Ensaios de adesão e proliferação celular usando linhagens de células pré-osteoblásticas MC3T3 foram realizados para avaliar o efeito das novas superfícies no comportamento celular in vitro. RESULTADOS: Os resultados demonstraram que a nitretação em plasma na configuração de gaiola catódica produz superfícies mais rugosas (p<0,02) e com menores ângulos de contato com a água. CONCLUSÕES: A adesão celular é maior nas superfícies mais rugosas do que nas superfícies polidas (p<0,05) e reagem de modo diferente a composição química do substrato e à topografia da superfície. / PURPOSE: The aim of this study was to evaluated the physico-chemical properties of different titanium surfaces modified by means of low temperature plasma nitridind on rat osteoblast cell adhesion and proliferation. METHODS: Pure Titanium discs grade II was submitted to three different surface preparations (polishing, glow discharge plasma nitriding in planar and cathodic cage configurations). Surface parameters as roughness, wettability and chemichal composition was determined to compare influency of gas mixture on the modified surface material properties. Cellular morphology was observed by scanning electron microscopy. To evaluate the effect of the surface on cellular response, osteoblast cells (MC3T3) adhesion and proliferation was quantified and data analised by Kruskal-Wallis and Friedman statistical tests. RESULTS: plasma nitriding discs shows rougher surfaces( p<0,02) in cathodic cage configuration and lower contact angle values. MC3T3 cells attached on rough surfaces produced by cathodic cage configuration was statistically significant p<0,05 compared to polished discs. CONCLUSIONS: Glow discharge plasma nitriding improve titanium surface roughness and wettability. MC3T3 cell adhesion behavior is related to substrate chemical composition and topography.

Page generated in 0.0798 seconds