• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 13
  • 11
  • 9
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Promoção da saúde do trabalhador de enfermagem: intervenção para o uso de luvas na punção venosa / Health promotion of nursing workers: intervention for the use of gloves in venous puncture.

Amanda Zapparoli Trandafilov 24 August 2009 (has links)
A execução da punção venosa periférica é uma atividade que expõe o profissional que a executa ao contato com sangue que pode ser um veículo transmissor de infecções. O objetivo do estudo foi validar o treinamento estruturado no modelo de promoção da saúde visando a mudança de comportamento de trabalhadores de enfermagem para o uso de luvas no procedimento de punção venosa periférica. Os delineamentos do estudo foram descritivo e quase-experimental e os procedimentos foram: adaptação da ferramenta, validação das variáveis do questionário, aplicação e avaliação do treinamento. A ferramenta de multimídia promoção da saúde no trabalho: uso de luvas na punção venosa foi adaptada da ferramenta promoção da saúde no trabalho: uso de luvas na administração de medicamentos, disponibilizada pela Rede de Prevenção de Acidentes de Trabalho, composta por questões prétreinamento, que identificam o comportamento dos profissionais, treinamento sobre o uso adequado de luvas e pós-treinamento, que identifica mudanças no comportamento. O procedimento de adaptação seguiu as etapas: definição do índice, criação do script, produção e disponibilização do software e controle de qualidade pós-produção. As variáveis do questionário foram validadas quanto ao conteúdo por 10 enfermeiros pesquisadores e quanto à consistência interna por meio do coeficiente alfa de Cronbach a partir de dados coletados com 30 trabalhadores de enfermagem, de outubro a novembro de 2008, do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, obtendo-se alfa global = 0,83. O treinamento foi aplicado em amostra de 96 trabalhadores de enfermagem do mesmo hospital, entre dezembro de 2008 e janeiro de 2009 em duas etapas: autoaplicação do treinamento e aplicação de um questionário um mês após a realização da primeira etapa. Na análise dos dados utilizou-se estatística descritiva, o teste Exato de Fisher e Correlação de Spearman. Os resultados identificaram que os fatores que influenciam o uso de luvas pelos trabalhadores são: percepção de benefícios (82,3%), autoeficácia do uso de luvas como equipamento de proteção individual (92,7%) e os que influenciam o não uso de luvas são: diminuição da sensibilidade tátil (82,3%), dificuldade para fixar o cateter (82,3%), tamanho inadequado (69,8%) e uso de luvas apenas quando conhecido o diagnóstico do paciente (54,2%). Apenas 20% dos sujeitos referiram estar satisfeitos com a qualidade das luvas oferecidas. Antes da aplicação do treinamento, 17,7% dos trabalhadores referiram usar luvas em 100% das vezes que executavam punção venosa e 75,1% dos sujeitos referiram a intenção de usá-las em todas as punções realizadas após o treinamento. Na avaliação realizada um mês depois do treinamento foi identificado que 35,4% dos sujeitos referiram que utilizaram luvas em todas as punções venosas realizadas, mostrando diferença estatisticamente significativa entre as variáveis (p=0,00). Houve correlação estatisticamente significativa entre a variável intenção de uso após o treinamento com as variáveis uso de luvas antes do treinamento e uso de luvas pelos colegas de trabalho (p<0,05). Conclui-se a eficácia do treinamento, no entanto sugere-se que outras medidas preventivas à exposição do trabalhador a material biológico devam ser associadas ao treinamento proposto. / The peripheral venous puncture is an activity that exposes professionals who perform it to blood potential carrier of infections. This study aimed to validate the structured training in the health promotion model with a view to change the behavior of nursing workers in the use gloves in the peripheral venous puncture procedure. This is a descriptive and quasi-experimental study whose procedures were: instrument adaptation, validation of the questionnaire variables, application and evaluation of training. The multimedia tool health promotion at work: the use of gloves in venous puncture was adapted from the tool health promotion at work: the use of gloves in the administration of medication available by the Network for the Prevention of Occupational Accidents. It is composed of pre-training questions that identify professionals behavior and training on the adequate use of gloves, and post training questions that identify behavioral changes. The procedure to adapt the instrument followed the stages: index definition, script elaboration, production and availability of software and post production quality control. The questionnaire variables were content validated by ten nursing researchers and their internal consistency was analyzed through Cronbachs Alfa coefficient (0.83) based on data collected from 30 nursing workers from October to November 2008 at the Hospital das Clínicas, University of São Paulo at Ribeirão Preto Medical School. Training was applied in a sample of 96 nursing workers at the same hospital with data collected between December 2008 and January 2009 in two stages: self-application of training and application of a questionnaire one month after the first stage completion. Descriptive statistics, Fishers exact test and Spearmans correlation were used in data analysis. Results revealed that the factors influencing workers use of gloves were: perception of benefits (82.3%), self-efficacy in the use of gloves as individual protection equipment (92.7%); and factors influencing the non-use of gloves were: diminished tactile sensitivity (82.3%), difficulty in fixing the catheter (82.3%), gloves inadequate size (69.8%) and use of gloves only when the patients diagnosis is known (54.2%). Only 20% of participants reported being satisfied with the quality of available gloves. Before the application of training, 17.7% of the workers reported using gloves in 100% of times they perform peripheral venous puncture and 75.1% reported intention to use them in all venous punctures performed after training. The evaluation carried out one month after training revealed that 35.4% of the participants reported the use of gloves in all venous punctures, which showed a statistically significant difference between variables (p=0.00). There was a statistically significant correlation between the variable commitment with a plan of action with the variables previous behavior and use of gloves by co-workers (p<0.05). The conclusion is that training is efficacious though we suggest that other preventive measures to workers exposure to biological material are associated to the proposed training.
12

O impacto do uso de diferentes tipos de luvas e das mãos nuas na inspeção e preparo do instrumento cirúrgico limpo / The impact of the use of different kinds of gloves and bare hands when handling surgical instruments

Camila Quartim de Moraes Bruna 17 March 2015 (has links)
Introdução: A inspeção e o acondicionamento dos instrumentais cirúrgicos limpos em caixas e bandejas, implicam na manipulação desses produtos. Na prática, é possível observar grande descompasso entre o cuidado dispensado a essa etapa, quando comparado ao rigor exigido para remoção completa de contaminantes por meio da limpeza. A falta de consenso quanto ao uso de luvas nessa etapa do processo chama a atenção e não se sabe se esse detalhe repercute na qualidade final do material quanto à segurança para o paciente cirúrgico. Objetivos: Determinar se há diferenças na resposta citotóxica relacionada ao uso de distintos tipos de luvas e das mãos nuas na inspeção e preparo do instrumental cirúrgico limpo e avaliar a carga microbiológica de instrumentais cirúrgicos preparados sem luvas e sua repercussão na esterilização. Método: Esta pesquisa realizou um experimento laboratorial com abordagem pragmática, utilizando cânulas de oftalmologia que foram manipuladas com diferentes tipos de luvas e com as mãos nuas. Posteriormente, o teste de citotoxicidade foi realizado por meio da difusão em ágar. Pinças anatômicas também fizeram parte da amostra para a análise exploratória microbiológica, após serem manipuladas sem luvas, e posteriormente, submetidas à avaliação de sua esterilidade, após autoclavação. Resultados: Nenhuma das amostras de cânulas de oftalmologia manipuladas por diferentes tipos de luvas e por mãos nuas apresentou efeito citotóxico.Todas as culturas microbiológicas das pinças anatômicas manipuladas sem luvas apresentaram crescimento de microrganismos aeróbios e anaeróbios, embora nenhum microrganismo tenha sido recuperado após a autoclavação. Conclusão: Não houve evidências de diferenças de resposta citotóxica relacionada ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas implica aumento dos custos do processo e na geração de resíduos, além do potencial risco alergênico ao látex. Esta pesquisa teve como relevância subsidiar a elaboração de protocolos para a etapa de preparo de instrumentais cirúrgicos limpos / Introduction: The aim of reprocessing surgical instruments is to provide instruments that are clean, in good working condition and ultimately sterile thus ensuring patient safety. During instrument there is no agreement about the necessity for glove use. Therefore, there is little reason for employees to wear gloves to protect themselves from possible residual contaminants on cleaned instruments that had previously been used during clean or sterile surgery. On the other hand, the use of the gloves to handle surgical instruments during preparation increases medical waste, increases medical costs and could increase the prevalence of glove allergies in staff. Aim: In this study we investigated the risk posed to patients from staff wearing different types of gloves or no gloves to prepare surgical kits. Method: Five cleaned ophtalmic cannulas were handled using different kinds of gloves and with bare hands, package and steam sterilized. An in vitro cytotoxicity test was conducted, using the agar diffusion test. Microbiological tests were conducted as well, in samples handled with bare hands. Results: All test samples showed the same mild reactivity (grade 2) indicating that handling instruments with gloves or bare hands did not leave any residual toxic products on the instrument surface. Conclusion: We found no difference in the iatrogenic risk to patients of either increased toxicity or increased risk of microbial contamination if surgical instruments are prepared with or without gloves. However, the use of gloves has some inherent disadvantages, such as the risk of latex sensitization of the workers and increased medical costs due to purchase and waste disposal
13

Aplicação de poli(anilina-co-3-aminobenzóico) e octadecil-trimetóxi-silano como revestimentos protetores de ligas de alumínio / Applicatio Polyaniline with 3-aminobenzoic and octadecyl-trimethyl-silane as protective coatings for aluminum alloys.

Marcela Jordan Sinisterra 25 April 2016 (has links)
Tendo em conta os constantes problemas que apresentasse com os processos de corrosão, o presente trabalho de pesquisa tem como foco principal a alteração nas propriedades de superfície das ligas de alumínio empregadas nas aeronaves, AA2024 e AA7075, utilizando mono e bicamadas baseadas de octadecil-trimetóxi-silano (ODTMS) + poli(anilina-co-3-aminobenzoico/PAni3ABA) a fim de encontrar melhores condições para a redução da corrosão puntiformes. Posteriormente, avalia-se as características protetoras dos filmes através de testes de corrosão, como potencial de circuito aberto, curvas de polarização anódica e espectroscopia de impedância eletroquímica visando a caracterização do comportamento eletroquímico das amostras. Também foram realizadas análises de microscopia óptica para verificar a eficiência de proteção contra a corrosão dos revestimentos propostos antes e após os ensaios de corrosão. Os resultados obtidos demonstram que as camadas utilizadas melhoram a resistência contra a corrosão na seguinte ordem: PAni3ABA > ODTMS + PAni3ABA > ODTMS, sendo a primeira a que apresentou os melhores resultados como maiores deslocamentos do Ecorr para valores mais positivos, diminuição da icorr e menor número de pontos de corrosão após a realização das curvas de polarização. Além de testes de aderência para os filmes também foram efetuadas caracterizações das ligas por MEV. / Taking into account the constant problems that presents with corrosion processes, this research work has focused primarily on the change in surface properties of aluminum alloys used in aircraft, AA2024 and AA7075, with mono and bilayers using as a base octadecyl trimethoxy silane (ODTMS) + poly (aniline-co-3-aminobenzoic / PAni3ABA) to find optimum conditions for reducing corrosion punctiform. Later, it evaluates the protective features of the films through corrosion tests such as open circuit potential, anodic polarization curves and electrochemical impedance spectroscopy in order to characterize the electrochemical behavior of the samples. They were also carried out optical microscopy analysis to verify the efficiency of protection against corrosion of the coatings proposed before and after corrosion testing. The results obtained show that the layers used improve corrosion resistance in the following order: PAni3ABA> ODTMS + PAni3ABA> ODTMS, the first being the one that presented the best results as larger shifts towards more positive values, reduced and fewer corrosion points after performing the polarization curves. In addition to compliance tests for the films were also made characterizations of alloys by SEM.
14

Avaliação da segurança microbiológica das luvas de látex para procedimento em uma unidade de terapia intensiva / Evaluation of the microbiological safety of latex gloves for procedures in an Intensive Therapy Unit

Adriano Menis Ferreira 19 October 2007 (has links)
Introdução: a utilização de luvas de látex para procedimentos é essencial nas atividades que envolvem risco biológico no cuidado à saúde, no entanto ainda é controversa a segurança microbiológica das luvas de procedimento, considerando sua exposição ambiental. Objetivos: quantificar as Unidades Formadoras de Colônias (UFC) das luvas de látex para procedimentos em momentos distintos (início, meio e fim das caixas) na situação real e controle de enluvamento; avaliar a contaminação das luvas conforme o tempo de exposição ambiental das caixas; isolar o microrganismo mais freqüente e determinar o perfil de sensibilidade aos antibióticos. Material e Método: trata-se de um estudo comparativo e prospectivo realizado em uma unidade de terapia intensiva de um hospital-escola. Após aprovação do comitê de ética em pesquisa, procedeu-se à coleta das amostras microbiológicas das luvas de látex por meio da digito-pressão em placas de Petri, preparadas com meio de cultura Mueller Hinton (MH). Esse procedimento foi realizado em 31 caixas de luvas de látex para procedimentos em diferentes momentos (início, meio e fim das caixas) e em situação real de enluvamento e controle. O Etest® foi utilizado na determinação do perfil de sensibilidade aos antibióticos (Ciprofloxacina®, Oxacilina®, Cefepime®, Gentamicina®, Amicacina® e Vancomicina®). Os dados foram submetidos a análise estatística por meio do Teste de Cochran e Spearman, considerando nível de significância de a=0,05. Para comparação do número de UFC, realizou-se análise de variância (ANOVA) com medidas repetidas. Resultados: totalizaram-se 372 placas de Petri, das quais 186 foram obtidas na situação real de enluvamento e 186 no controle. A média de UFC foi de 4,7, na situação controle, e de 6,2 na situação real de enluvamento, não demonstrando diferenças estatisticamente significantes (p=0,601). Em relação à avaliação dos pares de luvas no início, meio e fim da caixa na situação real de enluvamento e controle, não foram evidenciadas diferenças significantes no crescimento microbiano (UFC). Na associação entre o tempo de abertura ao término da caixa de luvas e o número de UFC, tanto na situação real de enluvamento quanto no controle, não houve correlação (p=0,63). Quanto aos microrganismos, a bactéria Staphylococcus spp. foi a mais freqüente. Com relação ao perfil de sensibilidade, 13 cepas (24,8%) apresentaram resistência a pelo menos 2 antibióticos; destas, 3 (5,5%) tiveram resistência a vancomicina. Conclusão: os resultados corroboraram a hipótese inicial da pesquisa quanto à segurança microbiológica das luvas de látex para procedimentos considerando os baixos valores de UFC. / Introduction: the use of latex gloves is essential and unquestionable in activities that involve biological risk in the health care. However, it is still controversial the microbiological safety of gloves for procedures considering their environmental exposition. Objectives: quantify the Colony-Forming Units (CFU) of latex gloves for procedures in different moments (beginning, middle and end of boxes) in real situation and gloving control; evaluate the contamination of gloves regarding the boxes time of environmental exposition; isolate the most frequent microorganism and determine the sensibility profile to antibiotics. Material and Method: It is a comparative and prospective study performed in an intensive therapy unit of a school hospital. After approval of the committee of ethics in research the collection of microbiological sample of latex gloves through digital pressure in Petri plaques prepared with culture media Mueller Hinton (MH) was initiated. This procedure was performed in 31 latex gloves boxes for procedures in different moments (beginning, middle and end of boxes) and, in real gloving and control situations. The Etest® was used to determine the sensibility profile of antibiotics (Ciprofloxacin®, Oxacillin®, Cefepime®, Gentamicin®, Amikacin® e Vancomycin®). The data was statistically analyzed through the Cochran and Spearman test considering a level of significance of a=0,05. Analysis of variance (ANOVA) with repetitive measures was used for the comparison of number of UFC. Results: a total of 372 Petri plaques were obtained, 186 in real gloving situation and 186 in the control situation. The CFU average was 4,7 in the control situation, and 6,2 in the real gloving situation, with no statistically significant differences (p=0,601). There was no evidence of significant differences in the microbial growth (UFC) in the evaluation of gloves pairs in the beginning, middle and end of boxes in both the real and control situations. There was no correlation (p=0.63) in the association between time of opening and finishing the box of gloves with the number of CFU, both in the real and control situations. The Staphylococcus spp. was the most frequent microorganism. Regarding the sensibility profile, 13 strains (24.8%) were resistant to at least two antibiotics; from these three (5.5%) resisted Vancomycin®. Conclusion: The results obtained support the initial hypothesis regarding the microbiological safety of latex gloves for procedures considering the low levels of CFU.
15

Análise microbiológica e genético-molecular da biota orotraqueal de paciente crítico: subsídios na prevenção da pneumonia associada à ventilação mecânica / Microbiological and genetic molecular analysis of the orotracheal biota of critical patients: support in the prevention of mechanical ventilator-associated pneumonia.

Souza, Paula Regina de 18 September 2009 (has links)
A assistência em Unidade de Terapia Intensiva (UTI) é constantemente desafiada por infecções, que resultam no aumento da morbimortalidade, no tempo de internação e nos custos. Objetivos: avaliar os paciente críticos com tubo endotraqueal submetidos à ventilação mecânica na perspectiva clínica e microbiológica com a finalidade de determinar a dispersão de Staphylococcus aureus, Staphylococcus coagulase-negativa e Pseudomonas aeruginosa na assistência respiratória destes pacientes. Assim, analisou aspectos quantitativos, perfil de sensibilidade aos antibióticos, similaridade genética e formação de biofilme em tubo traqueal considerando a presença ou não de PAVM. Trata-se de um estudo observacional prospectivo realizado na UTI de um hospital de emergência no interior do Estado de São Paulo. A coleta de dados clínicos envolveu pacientes adultos com período 48 horas de intubação endotraqueal em ventilação mecânica mediante consentimento do responsável. As amostras foram procedentes da saliva, secreção traqueal e tubo traqueal dos referidos pacientes; e da luvas utilizadas na aspiração do tubo endotraqueal. Utilizou-se no processamento das amostras recursos clássicos e avançados da microbiologia como Enterobacterial Repetitive Intergenic Consensus Sequence (ERIC-PCR), Eletroforese em Campo Pulsado e a microscopia eletrônica de varredura. A análise estatística pelo SPSS foi subsidiada em medidas de tendência central, tabelas de contingências, regressão múltipla e kappa, p<0,05. Na avaliação clínica dos 44 pacientes críticos, 34 (77,32%) eram masculinos, idade média de 39,9, e o motivo de hospitalização 19 (43,2%) foi devido à traumas. O período de hospitalização foi em média 10,9 dias (DP 9,3) e de permanência do tubo endotraqueal de 6,6 dias (DP 3,3). A ocorrência de infecção hospitalar foi de 31,2%, sendo que 15 (34,1%) eram PAVM; e 34,5% representaram o percentual de óbito. O período de permanência do tubo endotraqueal 8 dias foi fator de risco para PAVM (RR 4,00, p < 0,001) e regressão múltipla. Na análise microbiológica verificou-se que a presença das cepas foi variável em termos quantitativos segundo sua procedência. Houve predominância de contaminação nas luvas direitas com as cepas de Staphylococcus coagulase-negativa. A prevalência de resistência a oxacilina foi de 16,1% para Staphylococcus aureus e 22,6% Staphylococcus coagulasenegativa. Em termos de similaridade genética observou-se apenas um caso de Pseudomonas aeruginosa isoladas da saliva e tubo traqueal de um mesmo paciente. E, em 12 cepas evidenciou-se uma forte relação genética procedentes da saliva, do tubo traqueal. Dos Staphylococcus aureus e Staphylococcus coagulase-negativa ambos resistente a oxacilina foram similares as cepas procedentes da saliva e secreção traqueal. O biofilme presente nos 30 tubos apresentou estruturas celulares e microbianas específicas como: hemácias, rede de fibrina, leucócitos, além de cocos, bacilos, filamentos e leveduras, dentre outras. Embora com número reduzido de amostras os resultados sinalizaram para a possibilidade de dispersão microbiana endógena tendo a cavidade orofaríngea como o principal reservatório. Outras investigações em diferentes UTIs, em termos de microbiota, condições clínicas e institucionais são promissoras para que se possa de fato ampliar as evidências em torno do risco de infecção respiratória do paciente crítico em ventilação mecânica. / Care in Intensive Care Units (ICU) is constantly challenged by infections, which result in the increase of morbimortality, hospitalization length of stay and costs. Objectives: to assess critical patients with endotracheal tube on mechanical ventilation in the clinical and microbiological perspective, aiming to determine the diffusion of Staphylococcus aureus, coagulase-negative Staphylococcus and Pseudomonas aeruginosa in respiratory care to these patients. Quantitative aspects, sensitivity profile to antibiotics, genetic similarity and biofilm formation in tracheal tube considering the presence of mechanical ventilator-associated pneumonia (MVAP) were analyzed. It is an observational and prospective study carried out in the ICU of an emergency hospital in the interior of the state of São Paulo. Collection of clinical data involved adult patients in a period 48 hours of endotracheal intubation in mechanical ventilation, with the consent of the responsible person. Samples were collected from saliva, tracheal secretion and tracheal tube of the mentioned patients; and from the gloves used in aspiration of the endotracheal tube. Classic and advanced microbiological resources such as Enterobacterial Repetitive Intergenic Consensus Sequence (ERIC-PCR), Pulsed-Field Electrophoresis and electron scanning microscopy were used to analyze samples. Statistical analysis was done using SPSS and was supported by central tendency measures, contingency tables, multiple regression and kappa, p<0.05. The clinical evaluation showed that, of the 44 critical patients, 34 (77.32%) were male, with average age of 39.9 years. Trauma was the reason for hospitalization of 19 (43.2%) patients. The average period of hospitalization was 10.9 days (SD 9.3) and the period with endotracheal was 6.6 days (SD 3.3). The occurrence of cross infection was 31.2%, of which 15 (34.1%) were MVAP; and 34.5% represented the percentage of deaths. Length of stay of endotracheal tube 8 days was risk factor for MVAP (RR 4.00, p < 0.001) and multiple regression. Microbiological analysis showed that the presence of strains varied in quantitative terms according to their origin. There was predominance of contamination in right gloves with strains of coagulase-negative Staphylococcus. The prevalence of oxacillin resistance was 16.1% for Staphylococcus aureus and 22.6% for coagulase-negative Staphylococcus. As to the genetic similarity, it was observed only one case of Pseudomonas aeruginosa isolated from the saliva and tracheal tube of a same patient. In 12 strains, strong genetic relation from saliva and tracheal tube was evidenced. Staphylococcus aureus and coagulase-negative Staphylococcus, both oxacillin resistant, were similar to strains from saliva and tracheal secretion. Biofilm present in 30 tubes presented specific cellular and microbial structures, such as: red cells, fibrin network, leukocytes, besides cocci, rods, threads and yeasts, among others. Although with a reduced number of samples, results show the possibility of endogenous microbial diffusion, with the oropharynx cavity as the main reservoir. Further research in different ICUs, in terms of microbiota, clinical and institutional conditions, can broaden evidences regarding the risk of respiratory infection of critical patients on mechanical ventilation.
16

Análise microbiológica e genético-molecular da biota orotraqueal de paciente crítico: subsídios na prevenção da pneumonia associada à ventilação mecânica / Microbiological and genetic molecular analysis of the orotracheal biota of critical patients: support in the prevention of mechanical ventilator-associated pneumonia.

Paula Regina de Souza 18 September 2009 (has links)
A assistência em Unidade de Terapia Intensiva (UTI) é constantemente desafiada por infecções, que resultam no aumento da morbimortalidade, no tempo de internação e nos custos. Objetivos: avaliar os paciente críticos com tubo endotraqueal submetidos à ventilação mecânica na perspectiva clínica e microbiológica com a finalidade de determinar a dispersão de Staphylococcus aureus, Staphylococcus coagulase-negativa e Pseudomonas aeruginosa na assistência respiratória destes pacientes. Assim, analisou aspectos quantitativos, perfil de sensibilidade aos antibióticos, similaridade genética e formação de biofilme em tubo traqueal considerando a presença ou não de PAVM. Trata-se de um estudo observacional prospectivo realizado na UTI de um hospital de emergência no interior do Estado de São Paulo. A coleta de dados clínicos envolveu pacientes adultos com período 48 horas de intubação endotraqueal em ventilação mecânica mediante consentimento do responsável. As amostras foram procedentes da saliva, secreção traqueal e tubo traqueal dos referidos pacientes; e da luvas utilizadas na aspiração do tubo endotraqueal. Utilizou-se no processamento das amostras recursos clássicos e avançados da microbiologia como Enterobacterial Repetitive Intergenic Consensus Sequence (ERIC-PCR), Eletroforese em Campo Pulsado e a microscopia eletrônica de varredura. A análise estatística pelo SPSS foi subsidiada em medidas de tendência central, tabelas de contingências, regressão múltipla e kappa, p<0,05. Na avaliação clínica dos 44 pacientes críticos, 34 (77,32%) eram masculinos, idade média de 39,9, e o motivo de hospitalização 19 (43,2%) foi devido à traumas. O período de hospitalização foi em média 10,9 dias (DP 9,3) e de permanência do tubo endotraqueal de 6,6 dias (DP 3,3). A ocorrência de infecção hospitalar foi de 31,2%, sendo que 15 (34,1%) eram PAVM; e 34,5% representaram o percentual de óbito. O período de permanência do tubo endotraqueal 8 dias foi fator de risco para PAVM (RR 4,00, p < 0,001) e regressão múltipla. Na análise microbiológica verificou-se que a presença das cepas foi variável em termos quantitativos segundo sua procedência. Houve predominância de contaminação nas luvas direitas com as cepas de Staphylococcus coagulase-negativa. A prevalência de resistência a oxacilina foi de 16,1% para Staphylococcus aureus e 22,6% Staphylococcus coagulasenegativa. Em termos de similaridade genética observou-se apenas um caso de Pseudomonas aeruginosa isoladas da saliva e tubo traqueal de um mesmo paciente. E, em 12 cepas evidenciou-se uma forte relação genética procedentes da saliva, do tubo traqueal. Dos Staphylococcus aureus e Staphylococcus coagulase-negativa ambos resistente a oxacilina foram similares as cepas procedentes da saliva e secreção traqueal. O biofilme presente nos 30 tubos apresentou estruturas celulares e microbianas específicas como: hemácias, rede de fibrina, leucócitos, além de cocos, bacilos, filamentos e leveduras, dentre outras. Embora com número reduzido de amostras os resultados sinalizaram para a possibilidade de dispersão microbiana endógena tendo a cavidade orofaríngea como o principal reservatório. Outras investigações em diferentes UTIs, em termos de microbiota, condições clínicas e institucionais são promissoras para que se possa de fato ampliar as evidências em torno do risco de infecção respiratória do paciente crítico em ventilação mecânica. / Care in Intensive Care Units (ICU) is constantly challenged by infections, which result in the increase of morbimortality, hospitalization length of stay and costs. Objectives: to assess critical patients with endotracheal tube on mechanical ventilation in the clinical and microbiological perspective, aiming to determine the diffusion of Staphylococcus aureus, coagulase-negative Staphylococcus and Pseudomonas aeruginosa in respiratory care to these patients. Quantitative aspects, sensitivity profile to antibiotics, genetic similarity and biofilm formation in tracheal tube considering the presence of mechanical ventilator-associated pneumonia (MVAP) were analyzed. It is an observational and prospective study carried out in the ICU of an emergency hospital in the interior of the state of São Paulo. Collection of clinical data involved adult patients in a period 48 hours of endotracheal intubation in mechanical ventilation, with the consent of the responsible person. Samples were collected from saliva, tracheal secretion and tracheal tube of the mentioned patients; and from the gloves used in aspiration of the endotracheal tube. Classic and advanced microbiological resources such as Enterobacterial Repetitive Intergenic Consensus Sequence (ERIC-PCR), Pulsed-Field Electrophoresis and electron scanning microscopy were used to analyze samples. Statistical analysis was done using SPSS and was supported by central tendency measures, contingency tables, multiple regression and kappa, p<0.05. The clinical evaluation showed that, of the 44 critical patients, 34 (77.32%) were male, with average age of 39.9 years. Trauma was the reason for hospitalization of 19 (43.2%) patients. The average period of hospitalization was 10.9 days (SD 9.3) and the period with endotracheal was 6.6 days (SD 3.3). The occurrence of cross infection was 31.2%, of which 15 (34.1%) were MVAP; and 34.5% represented the percentage of deaths. Length of stay of endotracheal tube 8 days was risk factor for MVAP (RR 4.00, p < 0.001) and multiple regression. Microbiological analysis showed that the presence of strains varied in quantitative terms according to their origin. There was predominance of contamination in right gloves with strains of coagulase-negative Staphylococcus. The prevalence of oxacillin resistance was 16.1% for Staphylococcus aureus and 22.6% for coagulase-negative Staphylococcus. As to the genetic similarity, it was observed only one case of Pseudomonas aeruginosa isolated from the saliva and tracheal tube of a same patient. In 12 strains, strong genetic relation from saliva and tracheal tube was evidenced. Staphylococcus aureus and coagulase-negative Staphylococcus, both oxacillin resistant, were similar to strains from saliva and tracheal secretion. Biofilm present in 30 tubes presented specific cellular and microbial structures, such as: red cells, fibrin network, leukocytes, besides cocci, rods, threads and yeasts, among others. Although with a reduced number of samples, results show the possibility of endogenous microbial diffusion, with the oropharynx cavity as the main reservoir. Further research in different ICUs, in terms of microbiota, clinical and institutional conditions, can broaden evidences regarding the risk of respiratory infection of critical patients on mechanical ventilation.

Page generated in 0.0778 seconds