• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 33
  • 33
  • 15
  • 12
  • 11
  • 10
  • 10
  • 10
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Pulsformdiskrimination und Lichtausbeutemessungen von LAB-basierten Flüssigszintillatoren

Kögler, Toni 28 February 2011 (has links)
Die Grundlage vieler zukünftiger Flüssigszintillator-Neutrinoexperimente (SNO+, Daya Bay, LENA) ist das Lösungsmittel Lineare-Alkyl-Benzene (LAB, C6H5CnH2n+1, n = 10 - 13). Zusammen mit dem weit verbreiteten Szintillator 2,5-Diphenyloxazole (PPO) ist es ein farb- und geruchsloses Detektormaterial mit hohem Flammpunkt. Im Vergleich zu toluol- oder xylolbasierten Szintillatoren ist LAB+PPO preiswert und nicht gesundheitsschädlich. Die Eigenschaften von LAB machen es ebenfalls interessant für die Anwendung an nELBE, die Neutronenfugzeitanlage im Helmholtz-Zentrum Dresden - Rossendorf. Ein neuer Ansatz zur Bestimmung der Lichtausbeute im niederenergetischen Bereich (bis 2 MeV) wird vorgestellt. Kombiniert wurden Messungen mit (quasi) monoenergetischen Gammastrahlungs-Prüfstrahlern und einem in dieser Arbeit aufgebauten Compton-Spektrometer. Letzteres ermöglicht die Bestimmung der Lichtausbeute bis zu 5 keVee. Der Birks-Parameter wurde für eine Lösung von LAB + 3 g/l PPO sowie für den Flüssigszintillator NE-213 bestimmt. Die relative Lichtausbeute in Bezug auf letzteren konnte mit diesen Messmethoden ebenfalls ermittelt werden. Zur spektralen Analyse des Lumineszenzlichtes wurden Messungen an Fluoreszenz- und UV/VIS- Spektrometern durchgeführt. Die Pulsformdiskriminationsfähigkeit auf LAB basierenden Szintillatoren wurde während eines Flugzeitexperiments in einem gemischten n-gamma-Feld eines Cf(252)-Prüfstrahlers ermittelt. Dabei kamen unterschiedliche Algorithmen der semi-analogen und digitalen Pulsformdiskrimination zum Einsatz. / Linear alkyl benzene (LAB, C6H5CnH2n+1, n = 10 - 13) is the proposed solvent for the SNO+, the Daya Bay Neutrino and LENA experiment. In solution with the commonly used scintillator PPO it is a colourless, odourless and cheap liquid scintillator with a high fash point and low health hazard compared to toluene based ones. The properties of LAB make this scintillator interesting also for nELBE, the neutron time-of-fight facility at Helmholtz-Zentrum Dresden - Rossendorf. A new approach to measure the light yield in the low-energy range using a combination of quasi-monoenergetic photon sources and a Compton-spectrometer is described. The latter allows the measurement of the light yield down to 5 keVee (electron equivalent). The Birks- Parameter was determined for a homemade solution (LAB + 3 g/l PPO) and for NE-213. The light yield (relative to this standard scintillator) was confrmed by measurements using a fuorescence spectrometer. The ability of pulse-shape-discrimination in a mixed n-gamma- field of a Cf(252) source was tested using different digital and semi-analogue techniques.
32

Detektionsmethoden für Gammastrahlung in der therapeutischen Medizin mit CdZnTe-Detektoren

Weinberger, David 06 April 2018 (has links)
CdZnTe-Detektoren, zur direkten Messung von Gammastrahlung, die bei der Behandlung mit beschleunigten Teilchen entsteht, besitzen das Potential eine Reichweitenkontrolle zu ermöglichen und die Strahlendosis zu erfassen. Jedoch stellt die Identifizierung einzelner, energetisch nahe beieinander liegenden Photonenenergien, bei einem solchen Volumendetektor eine besondere Herausforderung dar. Die vorliegende Arbeit beschäftigt sich mit der Entwicklung von Methoden zur Korrektur der Signalformen am Volumenhalbleiter CdZnTe und der damit verbundenen Verbesserung der Energie- und Zeitinformation des Detektors. Dies ist wichtig für den Einsatz in der therapeutischen Medizin mit beschleunigten Teilchen, da Ladungsträger durch Gammastrahlung in unterschiedlichen Tiefen des Detektors generiert werden und einen tiefenabhängigen Fehler in der Detektorgenauigkeit erzeugen. / CdZnTe detectors, used for the direct measurement of gamma radiation generated during the treatment with accelerated particles, have the potential to provide a range control and to detect the radiation dose. However, the identification of individual energetically close photon energies in such a volume detector is a particular challenge. The present work deals with the development of methods for correcting the signal forms of the CdZnTe and the associated improvement of the energy and time information of the detector This is important for use in accelerated particle medicine because charge carriers are generated by gamma radiation at different depths of the detector and produce a depth dependent error in detector accuracy.
33

Étude et exploitation de bolomètres de nouvelle génération à électrodes concentriques pour la recherche de matière noire froide non-baryonique dans l’expérience Edelweiss II / Study of new germanium bolometers with interleaved concentric electrodes fot non-baryonic cold dark matter direct detection in the Edelweiss-II experiment

Domange, Jocelyn 30 September 2011 (has links)
EDELWEISS est une expérience de détection directe de matière noire froide non-baryonique sous forme de particules massives et faiblement interagissantes (connues sous l'acronyme de WIMPs), qui constituent actuellement les candidats les plus populaires pour rendre compte de la masse manquante de l'Univers. Dans ce but, EDELWEISS utilise des bolomètres de germanium opérés à température cryogénique (20 mK environ) dans le Laboratoire Souterrain de Modane (LSM) à la frontière franco-italienne. En particulier, depuis 2008, un nouveau type de détecteur est en fonctionnement, équipé d'électrodes concentriques pour optimiser le rejet des évènements de surface (détecteurs à grilles coplanaires). Cette thèse se décompose en plusieurs axes de recherche. Tout d'abord, nous avons réalisé des mesures concernant la collecte des charges dans les cristaux. Les lois de vitesse des porteurs (électrons et trous) ont été déterminées dans le germanium à 20 mK dans la direction <100>, et une étude complète de la répartition des charges a été menée, avec une évaluation de l'anisotropie du transport et de la diffusion transverse des porteurs. Ces résultats permettent d'avoir une meilleure compréhension du fonctionnement interne des détecteurs d'Edelweiss. Ensuite, des études portant sur l'amélioration des performances ont été effectuées. Nous avons en particulier permis d'optimiser la procédure de régénération des cristaux et améliorer le rejet passif des évènements de surface (β). Le volume utile de détection des détecteurs a été évalué en utilisant les raies de deux radio-isotopes activés cosmiquement, le 68Ge et le 65Zn. Enfin, une étude exhaustive portant sur l'étude des spectres à basse énergie a été menée, ce qui permet de mettre au point une méthode d'analyse systématique pour la recherche de WIMPs de basse masse dans EDELWEISS. / EDELWEISS is a direct non-baryonic cold dark matter detection experiment in the form of weakly interacting massive particles (also known as WIMPs), which currently constitute the most popular candidates to account for the missing mass in the Universe. To this purpose, EDELWEISS uses germanium bolometers at cryogenic temperature (20 mK approximately) in the Underground Laboratory of Modane (LSM) at the French-Italian border. Since 2008, a new type of detector is operated, equipped with concentric electrodes to optimize the rejection of surface events (coplanar-grid detectors). This thesis work is divided into several research orientations. First, we carried out measurements concerning charge collection in the crystals. The velocity laws of the carriers (electrons and holes) have been determined in germanium at 20 mK in the <100> orientation, and a complete study of charge sharing has been done, including an evaluation of the transport anisotropy and of the straggling of the carriers. These results lead to a better understanding of the inner properties of the EDELWEISS detectors. Then, studies relating to the improvement of the performances were carried out. In particular, we have optimized the space-charge cancellation procedure in the crystals and improved the passive rejection of surface events (β). The fiducial volume of the detectors has been evaluated using two X-ray lines from cosmically activated radionuclides: 68Ge and 65Zn. Lastly, an exhaustive study of the low energy spectra has been carried out, which makes it possible to develop a systematic analysis method for the search of low-mass WIMPs in EDELWEISS.

Page generated in 0.0329 seconds