• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 984
  • 20
  • 20
  • 20
  • 16
  • 15
  • 11
  • 6
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1026
  • 410
  • 396
  • 352
  • 215
  • 206
  • 172
  • 115
  • 101
  • 99
  • 98
  • 93
  • 79
  • 76
  • 75
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Perfil longitudinal de uma lagoa facultativa de tratamento secundário de esgoto doméstico aplicada nas condições ambientais do sul do Brasil

Gotardo Jackeline Tatiane January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental. / Made available in DSpace on 2013-07-16T01:59:55Z (GMT). No. of bitstreams: 1 220881.pdf: 2856009 bytes, checksum: 1e69416a0660a25b0e0c0e7b15428907 (MD5) / Neste trabalho, estudou-se uma lagoa facultativa de tratamento de esgoto secundário, em escala piloto, na região sul do Brasil, avaliando as características do perfil longitudinal e o desempenho da mesma na remoção da matéria carbonácea, nitrogenada e qualidade bacteriológica. A lagoa piloto possui volume útil de 17,5m3 e área superficial de 15,2 m2 (profundidade de 1,15 m, comprimento de 9,5 m e largura de 1,60 m). Para caracterizar o comportamento da matéria carbonácea foram avaliados 3 pontos distintos na extensão longitudinal da lagoa. O monitoramento foi conduzido em 3 fases operacionais (fase 1: TDH=20d, Tmédia=28ºC, primavera/verão; fase 2: TDH=10 d, Tmédia=24ºC, verão/outono; fase 3: TDH=20d, Tmédia=19ºC, inverno/primavera), sendo avaliado as características físico-químicas e bacteriológicas semanalmente e monitoramento climatológico/operacional três vezes por semana. A avaliação foi efetuada através dos seguintes parâmetros: pH, OD, temperatura, transparência por disco de Secchi, turbidez, Alcalinidade Total, DQOt, DQOs, DBOt, DBOs, SS, Clorofila a, N-NH4+, N-NO2-, N-NO3-, P-PO43- reativo, coliformes totais, Escherichia coli e comunidade planctônica. Os resultados obtidos na avaliação do perfil longitudinal não demonstraram diferença significativa dos parâmetros nos 3 pontos avaliados, caracterizando a lagoa como reator de mistura completa. O coeficiente cinético calculado nas diferentes condições operacionais apresentou valores de DBO5 entre 0,12-0,20 d-1 para mistura completa. A DQO apresentou valores de coeficiente cinético entre 0,04-0,19 d-1 para mistura completa. A relação entre taxa aplicada e taxa removida de DQO resultou na equação y=-39,9 + 1,02x, (y=taxa removida; x=taxa aplicada), r2=0,81. A relação entre a taxa aplicada e taxa removida de DBO5 apresentou a equação y= -4,03 + 0,71x, r2=0,6. A eficiência na transformação do nitrogênio foi de 62 %, 40% e 42%, respectivamente para a primeira, segunda e terceira fase. A eficiência na transformação do fosfato reativo foi em média 26 %, 60% e 71%, respectivamente para a primeira, segunda e terceira fase. A qualidade sanitária, através do indicador E coli e em termos de unidade logarítmica, apresentou eficiência significativa, valores de 2,6 log; 1,4 log e 1,2 log, respectivamente para a primeira, segunda e terceira fase. A comunidade planctônica avaliada qualitativamente apresentou predominância de espécies de Euglenophyta (73%) e Clorophyta (69%). O perfil horário demonstrou que ocorrem oscilações horárias na qualidade do efluente. Através dos dados obtidos pelo balanço hídrico, constatou-se diluição máxima do efluente de 20% na terceira fase do estudo, porém não comprometeu a eficiência da lagoa. De um modo geral, a fase 3 (TDH=20d) apresentou resultados mais eficazes na remoção da matéria carbonácea e do fosfato reativo. A fase 1 (TDH=20d) foi mais eficaz na avaliação da qualidade sanitária através do indicador E. coli e na transformação do nitrogênio amoniacal. Entretanto, a fase 2 (TDH=10d), apesar de valores menos expressivos, apresentou valores satisfatórios para todos os parâmetros.
92

Avaliação de desreguladores endócrinos e do micropoluente colesterol em estações de tratamento de esgoto sanitário / Endocrine disruptors. Effluent treatment station. Gas chromatography. Ecotoxicity. Emerging micropollutants

Pessoa, Germana de Paiva 23 November 2012 (has links)
PESSOA, G. P. Avaliação de desreguladores endócrinos e do micropoluente colesterol em estações de tratamento de esgoto sanitário. 2012. 213 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2013-06-24T14:16:57Z No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-06-28T17:31:36Z (GMT) No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) / Made available in DSpace on 2013-06-28T17:31:36Z (GMT). No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) Previous issue date: 2012-11-23 / Endocrine disruptors chemicals (EDCs), whose presence in sewage is mainly attributed to the natural hormones 17 -estradiol (E2) and estrone (E1) and to the synthetic one 17-ethinylestradiol (EE2), the main active ingredient of oral contraceptives, can cause a series of disturbances in the reproductive organs of humans and animals, since such compounds are not readily removed by biological processes of conventional treatment, being improperly released into water bodies. However, the above mentioned compounds are found at low concentrations (ng L -1/μg L -1) in aqueous environmental matrices, which make their detection and quantification an analytical challenge. Thus, an analytical methodology using gas chromatography coupled to mass spectrometry (GC/MS) was developed and optimized in order to evaluate the removal efficiency of EDs and the micropollutant cholesterol (CHOL) in wastewater treatment plants (WWTPs) from the Metropolitan Area of Fortaleza, as well as to detect them in surface waters. Acute and chronic ecotoxicity tests with effluents and EDs using the microcrustacean Daphnia magna as bioindicator. Five WWTPs were evaluated, which were divided in four types of technologies, namely: two WWTPs with facultative pond followed by maturation pond (FP+MP1 and FP+MP2), facultative pond (FP), activated sludge followed by chlorination step (AS+Cl) and upflow anaerobic sludge blanket reactor followed by chlorination step (UASB+Cl). The mean concentrations for micropollutants in effluents were: 557.4 ng.L-1 (E1), 144.4 ng.L-1 (E2), 266.4 ng.L-1 (E2-17A), 421.4 ng.L-1 (EE2) and 4691.9 ng.L-1 (CHOL). The maximum values obtained in surface water were: 212.75 ng.L-1 (E1), 256.25 ng.L-1 (E2) and 1175 ng.L-1 (CHOL). The estrogens E2-17A and EE2 were not detected. Regarding the EDs removal, the lowest removal efficiencies were found for low-rate systems (stabilization ponds) with 68.1% (FP+MP1), 79.9% (FP+MP2) and 54.0% (FP). The high-rate systems obtained satisfactory removal efficiency: 93.4% (LA+Cl), 95.4% (UASB+Cl). For CHOL, the best removal was obtained by the WWTP FP+MP2 with 94%, followed by the WWTPs AS+Cl (88%) and UASB+Cl (82%). No toxicity was detected in the effluent from the WWTP FP+MP2, however, in the effluents from FP+MP1 and FP, maximum EC50-48h was 61% and 57%, respectively. The toxicity level in the effluents from WWTPs UASB and AS was higher than that obtained in the influents. Probably, the toxicity increase was due to the presence of residual chlorine in the effluent since it was collected after the chlorination step. Concerning the chronic toxicity, significant effect in terms of reproduction (p <0.05) was detected only in the effluent from the WWTP FP+MP2 with NOEC (no observed effect concentration) of 20% and OEC (observed effect concentration) of 30%. In the effluents from the WWTPs AS+Cl and UASB+Cl, the OEC value for survival evaluation was 5%, evidencing the high toxicity. In the assay with a multielement estrogens solution, the survival chronic effect was not observed. However, there was a chronic effect in terms of sex change, showing values of NOEC and OEC of 2 and 4 μg.L-1, respectively. In terms of reproduction, NOEC was 4 μg.L-1 and CEO of 1 μg.L-1. Based on these results, it can be concluded that there is a need for optimization of WWTPs operational parameters in order to improve micropollutants removal efficiency. / Os desreguladores endócrinos (DEs), cuja presença em esgotos sanitários deve-se principalmente aos hormônios naturais 17 β-estradiol (E2) e estrona (E1) e ao sintético 17α-etinilestradiol (EE2), principal substância ativa do contraceptivo oral, podem causar uma série de distúrbios nos órgãos reprodutores dos seres humanos e animais, haja vista que tais compostos não são prontamente removidos por processos biológicos de tratamento convencionais, sendo lançados de forma inadequada em corpos d’água. No entanto, os compostos supramencionados se encontram em baixas concentrações (ng.L-1/μg.L -1) em matrizes ambientais aquosas, tornando sua detecção e quantificação um desafio analítico. Deste modo, buscou-se desenvolver e otimizar uma metodologia analítica utilizando a técnica de cromatografia gasosa acoplada a espectrometria de massas (CG/MS) com o objetivo de avaliar a eficiência de remoção dos DEs e do micropoluente colesterol (CHOL) em Estações de Tratamento de Esgotos (ETEs) da Região Metropolitana de Fortaleza, assim como detectá-los em águas superficiais. Foram realizados ensaios de ecotoxicidade aguda e crônica com os efluentes e DEs, utilizando o microcrustáceo Daphnia magna como bioindicador. Foram avaliadas cinco ETEs, sendo quatro tipos de tecnologias, a saber: duas ETEs com lagoa facultativa seguida de lagoa de maturação (LF+LM1 e LF+LM2), lagoa facultativa (LF), lodos ativados seguido da etapa de cloração (LA+Cl) e reator de manta de lodo e fluxo ascendente seguido da etapa de cloração (UASB+Cl). As concentrações médias para os micropoluentes nos efluentes foram: 557,4 ng.L-1 (E1); 144,4 ng.L-1 (E2); 266,4 ng.L-1 (E2-17A); 421,4 ng.L-1 (EE2) e 4691,9 ng.L-1 (CHOL). Os valores máximos obtidos nas águas superficiais foram de: 212,75 ng.L-1 (E1); 256,25 ng.L-1 (E2) e 1175 ng.L-1 (CHOL). Os estrogênios E2-17A e EE2 não foram detectados. Com relação à remoção dos DEs, as menores eficiências de remoção foram encontradas para os sistemas de baixa taxa (lagoas de estabilização) com 68,1% (LF+LM1); 79,9% (LF+LM2) e 54,0% (LF). Os sistemas de alta taxa obtiveram eficiências de remoção satisfatórias: 93,4% (LA+Cl); 95,4% (UASB+Cl). Para o CHOL o melhor índice de remoção foi obtido na ETE LF+LM2 com 94%, seguida das ETEs LA+Cl (88%) e UASB+Cl (82%). Com relação à avaliação ecotoxicológica aguda, não foi detectada toxicidade no efluente proveniente da ETE LF+LM2, entretanto, nos efluentes da LF+LM1 e LF, a CE50-48h máxima foi de 61% e 57%, respectivamente. O nível de toxicidade nos efluentes das ETE LA+Cl e UASB+Cl foi maior que o obtido nos afluentes. Provavelmente, o aumento de toxicidade deve-se à presença de cloro residual no efluente, uma vez que este era coletado após a etapa de cloração. Tratando-se de toxicidade crônica, foi detectado efeito significativo em termos de reprodução (p < 0,05) apenas no efluente proveniente da ETE LF+LM2 com CENO (concentração de efeito não observado) de 20% e CEO (concentração de efeito observado) de 30%. Nos efluentes provenientes das ETE LA+Cl e UASB+Cl, o valor de CEO para a avaliação de sobrevivência foi de 5%, evidenciando a elevada toxicidade. No ensaio realizado com a solução multielementar de estrogênios, o efeito crônico de sobrevivência não foi observado, no entanto foi observado um efeito crônico em termos de mudança de sexo, apresentando valores de CENO e CEO de 2 e 4 μg.L-1, respectivamente. Em termos de reprodução, o CENO foi de 4 μg.L-1 e o CEO de 1 μg.L-1. Diante dos resultados obtidos, pode-se concluir que existe uma necessidade de otimização dos parâmetros operacionais das ETEs com o objetivo de melhorar a eficiência de remoção de micropoluentes.
93

Avaliação da microaeração na eficiência, estabilidade operacional, qualidade do biogás e controle de odor em sistemas anaeróbios de tratamento / Assessment microaeração in efficiency, stability operations, quality biogas and odor control systems anaerobic

Oliveira, Carla Jamile Sobreira de January 2013 (has links)
OLIVEIRA, C. J. S. Avaliação da microaeração na eficiência, estabilidade operacional, qualidade do biogás e controle de odor em sistemas anaeróbios de tratamento. 2013. 105 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-04-04T13:48:52Z No. of bitstreams: 1 2013_dis_cjsoliveira.pdf: 2330417 bytes, checksum: 9f62cfbdec9bd08e9aaf71a603699a02 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-05-06T18:16:21Z (GMT) No. of bitstreams: 1 2013_dis_cjsoliveira.pdf: 2330417 bytes, checksum: 9f62cfbdec9bd08e9aaf71a603699a02 (MD5) / Made available in DSpace on 2014-05-06T18:16:21Z (GMT). No. of bitstreams: 1 2013_dis_cjsoliveira.pdf: 2330417 bytes, checksum: 9f62cfbdec9bd08e9aaf71a603699a02 (MD5) Previous issue date: 2013 / This research work evaluated the feasibility of the micro-aerobic process to remove sulfide from biogas in order to control biogas quality and odors in wastewater treatment plants (WWTP). Moreover, the impact of micro-aeration over the anaerobic system stability was evaluated, and a comparison of the micro-aerobic biotechnology with a chemical absorption process (NaOH) for sulfide removal from biogas was performed. The experiments were performed in a continuous mode in two acrylic-constructed mesophilic (28º C) bioreactors fed with synthetic wastewater. The experiment consisted into four operation phases for both reactors, being the two first phases used for the stabilization of the systems. During the operation phase III, sodium sulfate was introduced into the reactors at a COD/SO42- ratio of ~7. At the operation phase IV, the hydrogen sulfide removal systems were applied into the reactors, i.e. the reactor 1 (R1) was operated under strictly anaerobic conditions with a biogas caustic scrubbing, and the reactor 2 (R2) was operated at micro-aerobic conditions by using a 0,2 mL.min-1 atmospheric air injection into the headspace of the system. Physical-chemical analyses, such as COD, pH, alkalinity, sulfate, dissolved sulfide was performed, and biogas was characterized in terms of N2, O2, CH4, CO2, H2S, NH3. During the operation phases III and IV, both rectors showed a good stability in terms of COD removal (>80%) and sulfate removal (>90%). During the micro-aerobic process, the introduced oxygen did not affect organic matter removal. Regarding biogas quality, content of methane in the micro-aerobic system decreased to a value of 76% (phase III) and 52% (phase IV), due to the dilution with the nitrogen present in air. Meanwhile, when nitrogen interference was removed, similar concentrations to the anaerobic phase (phase III) were obtained, suggesting that methanogenic archaea was not significantly affected by the introduced oxygen. Regarding to sulfide removal, the micro-aerobic process was effective, both removing sulfide from the liquid and the gaseous phases, showing an average removal of 42% e 94%, respectively. The biogas cleaning process applied to R1 showed a 100% sulfide removal from biogas and 100% removal of CO2 and NH3. In this way, both, the micro-aerobic and the scrubbing processes were efficient for sulfide removal and can be used for odor control in WWTP. The preliminary economical study considering two technologies (micro-aerobic and the scrubbing) showed that even taking into account the initial investment for the aeration and the electricity costs for the continuous aeration, the operational costs with the chemical acquisition for the scrubbing process are much higher. Likely, the micro-aerobic process will be more advantageous than the scrubbing process after a detailed economic analysis or a life cycle assessment, however, it is necessary to perform more research in order to confirm these hypotheses. / Esta pesquisa avaliou o sistema microaeróbio como estratégia simples de remoção de sulfeto de hidrogênio da fração gasosa com vistas ao controle de odor e qualidade do biogás em estações de tratamento de esgotos (ETE). Adicionalmente, foi avaliado o impacto da microaeração na estabilidade operacional do sistema anaeróbio, além de um estudo comparativo entre a tecnologia microaeróbia e absorção química (NaOH) na remoção de H2S presente no biogás. Os experimentos foram conduzidos em fluxo contínuo em dois reatores mesofílicos (28°C) construídos em acrílico e alimentados com água residuária sintética. O experimento foi dividido em quatro fases de operação, para ambos os reatores, de modo que as duas primeiras fases foram para a estabilização dos reatores. Na fase III foi introduzido sulfato de sódio, em uma relação DQO/SO42- de aproximadamente 7. Por fim, na fase IV foram adicionados aos reatores os sistemas de remoção de H2S, ou seja, o reator 1 (R1) foi operado em condições estritamente anaeróbias com lavagem cáustica do biogás, enquanto que o reator 2 (R2) foi modificado para operar em condições microaeróbias a partir da injeção de 0,2 mL.min-1 de ar atmosférico em seu headspace. Foram realizadas análises físico-químicas no afluente e efluente dos reatores, como DQO, pH, alcalinidade, sulfato, sulfeto dissolvido e feita a caracterização do biogás em termos de N2, O2, CH4, CO2, H2S, NH3. Foi observado nas fases III e IV que ambos os reatores apresentaram boa estabilidade em termos de remoção de DQO (>80%) e remoção de sulfato (>90%). Durante o processo microaeróbio o oxigênio adicionado não modificou a remoção da matéria orgânica. Em relação à qualidade do biogás, observou-se que o conteúdo de metano no sistema provido de microaeração foi reduzido de 76% (Fase III) para 52% (Fase IV), devido à diluição com o nitrogênio presente no ar atmosférico. Entretanto, ao retirar a interferência do N2 foram obtidas concentrações próximas ao da fase totalmente anaeróbia (Fase III), indicando, portanto, que as arquéias produtoras de metano não foram afetadas significativamente pelo oxigênio introduzido. Em relação à remoção de sulfeto, o processo microaeróbio foi efetivo na redução tanto na fase líquida como na gasosa, com remoção média de 42% e 94%, respectivamente. O processo de lavagem do biogás aplicado no R1 promoveu remoção de 100% do H2S do biogás bem como 100% de CO2 e NH3. Dessa forma, tanto o processo microaeróbio como a lavagem foram eficientes na remoção do H2S e podem ser empregados no controle de odor em ETE. O estudo econômico preliminar das duas tecnologias (microaeróbio e lavagem cáustica) mostra que apesar do investimento inicial necessário para a instalação do processo microaeróbio e os custos de eletricidade para aeração contínua dos reatores, os custos operacionais com a aquisição do reagente químico no processo de lavagem superam os custos totais ao longo do tempo. Por fim, espera-se que o sistema microaeróbio seja mais vantajoso do que a lavagem química tanto sob o ponto de vista econômico em uma análise mais detalhada quanto na análise de ciclo de vida, mas que novos estudos devam ser conduzidos para comprovar tais hipóteses.
94

Biorreator à membrana de leito móvel em bateladas sequenciais para a remoção de nutrientes e matéria orgânica de efluentes sanitários

Kellner, Ronaldo Luis January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:01:57Z (GMT). No. of bitstreams: 1 327417.pdf: 2106085 bytes, checksum: 376fec6024ab7da7581d28ca7a72bf76 (MD5) Previous issue date: 2014 / Este trabalho aborda o tratamento de efluentes sanitários considerando a remoção de nutrientes como nitrogênio e fósforo, bem como a degradação da matéria orgânica em biorreatores à membrana. A operação do biorreator compreendeu 210 dias, nos quais o sistema foi operado com intermitência entre etapas anóxicas e aeróbias para a adequada ocorrência dos fenômenos biológicos. Assim, os objetivos deste trabalho são: avaliar a remoção de nutrientes em um Biorreator à Membrana de Leito Móvel em Bateladas Sequenciais. Para a realização destes objetivos, foram utilizadas metodologias de mensuração dos componentes estudados, como nitrogênio total, nitrogênio amoniacal, nitrito, nitrato, DQO, fósforo total, ortofosfato, além de análises pontuais como respirometria, Velocidade específica de consumo de amônia, de nitrato e de fosfato. Em termos de DBO e DQO atingiu-se 99,8 e 97,3% de remoção respectivamente. Para o nitrogênio total, obteve-se 86% de remoção, sendo que para amônia atingiu-se 99,5%. Para o fósforo, identificou-se grande flutuação na remoção em função da temperatura, atingindo em média 70% durante o período mais frio e cerca de 56% para todo o período. Identificou-se, ainda, a influência positiva do material suporte na remoção de fósforo, através dos ensaios da Velocidade específica de consumo de fosfato. O sistema se mostrou eficiente e estável na remoção dos compostos testados, atingindo melhores respostas do que sistemas convencionais para o tratamento de efluentes.<br> / Abstract : This paper addresses the treatment of wastewater considering the removal of nutrients such as nitrogen and phosphorus, as well as the degradation of organic matter in membrane bioreactors The operation of the bioreactor comprised 210 days in which the system was operated intermittently between anoxic and aerobic steps to the proper occurrence of biological phenomena. Thus , the specific objectives of this study were to assess the nutrient removal in a Membrane Bioreactor Moving Bed in Sequential Batch . Methodologies for measuring the components studied , such as total nitrogen , ammonia nitrogen , nitrite, nitrate , COD , total phosphorus , orthophosphate were used in addition to individual analyzes as respirometry , the removal rate of ammonia , nitrate and phosphate. In terms of BOD and COD was reached 99.8 and 97.3 % removal respectively. For total nitrogen, was obtained 86 % removal , and ammonia was reached to 99.5%. To phosphorus, we identified large fluctuations in removing a function of temperature , averaging 70 % during the coldest period and about 56 % for the entire period . It was also identified the positive influence of carriers for phosphorus removal by FISH and the rate of removal of phosphate. The system is efficient and stable in the removal of the compounds tested, achieving better response than conventional systems for effluent treatment .
95

Remoção de Cryptosporidium spp. no tratamento de águas por filtração em margem

Jangada, Victor Hugo January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:12:45Z (GMT). No. of bitstreams: 1 327994.pdf: 1803321 bytes, checksum: 56a909b73b9a9f302a055a42abe66ab2 (MD5) Previous issue date: 2014 / Com a crescente preocupação a respeito da poluição hídrica e as possíveis doenças que possam ser causadas através da contaminação com protozoários, surge a filtração em margem como uma das possíveis soluções para o problema, já que pode remover através de filtração os organismos que são resistentes a desinfecção química e algumas vezes podem acabar atingindo as redes de distribuição. Sendo assim, este trabalho objetivou avaliar a eficiência da filtração em margem em colunas de sedimento para remoção de Cryptosporidium spp. através do uso microesferas de poliestireno para simulação deste protozoário. Para consecução desta pesquisa, foi realizado um estudo contendo 5 colunas filtrantes a fim de simular os primeiros metros da filtração em margem, onde foram aplicadas as microesferas simuladoras do protozoário Cryptosporidium spp. Previamente a aplicação das microesferas, procurou-se identificar a quantidade de tempo necessária para que o sistema piloto fosse considerado aclimatado. O controle da qualidade da água produzida pela filtração em margem foi realizado através do monitoramento dos seguintes os parâmetros: carbono orgânico total, coliformes totais, condutividade, cor aparente, cor verdadeira, E. Coli, oxigênio dissolvido, pH, sólidos dissolvidos totais, temperatura e turbidez. A análise das microesferas de poliestireno foi realizada em microscópio de fluorescência. Com base nos resultados obtidos, considera-se aclimatado o sistema piloto após 45 dias de operação, pois nessa altura já é possível alcançar resultados suficientemente bons para se enquadrarem na Portaria nº 2914/2011. Foi também possível concluir que a filtração em margem mostrou-se efetiva na remoção de microesferas de poliestireno a partir de 3 m de leito filtrante. No que diz respeito a turbidez como indicador da presença de Cryptosporidium spp., considera-se que este não corresponde a um indicador confiável, pois houve a presença das microesferas de poliestireno até mesmo quando a turbidez alcançava valores menores que 0,5 uT, como recomenda a legislação brasileira.<br> / Abstract : With the increasing concern about water pollution and possible diseases that may be caused by contamination with protozoa, rises the bank filtration as a possible solution to the problem, since it can remove by filtration, organisms that are resistant to chemical disinfection and can sometimes end up reaching the distribution networks. Thus, this study aimed to evaluate the efficiency of bank filtration by sediment columns for the removal of Cryptosporidium spp. through the use of microspheres for simulation of this protozoan. To achieve this research, was performed a study containing 5 filter columns to simulate the first few meters of bank filtration, where the microspheres simulating the protozoan Cryptosporidium spp. was applied. Previously the application of microspheres, sought to identify the amount of time required for the pilot system to be considered acclimated. The control of the water quality produced by bank filtration was performed by monitoring the following parameters: total organic carbon, total coliform, conductivity, apparent color, true color, E. Coli, dissolved oxygen, pH, total solids dissolved, temperature and turbidity. The analysis of polystyrene microspheres was performed with a fluorescence microscope. Based on the results obtained, it is considered acclimated the pilot system after 45 days of operation, because then it is possible to achieve results good enough to fit the Brazilian legislation. It was also concluded that the bank filtration proved to be effective in the removal of polystyrene microspheres from 3 m filter bed. Regarding the turbidity as an indication of the presence of Cryptosporidium spp., it is considered that this does not correspond to a reliable indicator because there was the presence of polystyrene microspheres even when the turbidity reached values lower than 0,5 NTU, as recommended in Brazilian legislation.
96

Lectinas da esponja marinha Haliclona (Soestella) caerulea / Lectins from the marine sponge Haliclona (Soestella) caerulea

Carneiro, Rômulo Farias January 2013 (has links)
CARNEIRO, R. F. Lectinas da esponja marinha Haliclona (Soestella) caerulea. 2013. 127 f. Dissertação (Mestrado em Bioquímica) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2015-01-22T17:27:45Z No. of bitstreams: 1 2013_dis_rfcarneiro.pdf: 4260974 bytes, checksum: c0be525bfa10b20a04540ce33ef61d2e (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2015-12-08T21:36:29Z (GMT) No. of bitstreams: 1 2013_dis_rfcarneiro.pdf: 4260974 bytes, checksum: c0be525bfa10b20a04540ce33ef61d2e (MD5) / Made available in DSpace on 2015-12-08T21:36:29Z (GMT). No. of bitstreams: 1 2013_dis_rfcarneiro.pdf: 4260974 bytes, checksum: c0be525bfa10b20a04540ce33ef61d2e (MD5) Previous issue date: 2013 / Lectins are proteins/glycoproteins that recognize carbohydrate of a specific way, but not participate in the metabolism of the same and do not belong to any of major classes of immunoglobulins. Lectins are ubiquitous proteins, present in all known organisms. In animal cells, lectins have been found in the cytoplasm, in the nucleous and as membrane-associated proteins, in diverse organelles and cells. Animal lectins can be classified into distinct families based on their physicochemical characteristics, especially in their function and identity of primary and tertiary structure. The aim of this study was to purify, characterize structural and biologically new lectins from the marine sponge Haliclona (Soestella) caerulea. H. caerulea specimens were collected in Paracuru beach, Ceará. Two lectins (H-1 and H-3) were isolated by classical techniques of protein chemistry. The primary structure of H-3 was determined by mass spectrometry and RACE. The toxic activity of lectins was evaluated against Artemia nauplii and Escherichia coli and Staphylococcus aureus strains. H-1 and H-3 showed distinct characteristics of the lectin previously isolated from H. caerulea. H-1 is a monomeric protein of 40 kDa whereas H-3 is a heterogeneus protein with chains of 9, 16 and 18 kDa. H-3 binds human erythrocytes of A and B type and was inhibited by GalNAc and PSM, H-1 binds different blood groups and could not be inhibited by any sugar tested. H-1 was toxic to Artemia nauplii (LC50 = 6.4 μg.mL-1) and H-3 was not considered toxic (LC50 = 414.2 μg.mL-1). H-3 is a blue protein that interacts with a chromophore of 597 Da of maximum absorbance at 620 nm. The primary structure of H-3 revealed a unique amino acid sequence no similar to any animal lectins known. H-3 has a hybrid glycan comprising by Hex7NAcHex7DeoxiHex2. The α-chain of H-3 undergoes complex proteolytic processing that not been fully elucidated. Moreover, H-3 was crystallized, but was not possible to obtain a diffraction pattern that permits solving the structure. In short, two new lectins were isolated and out first observed the interaction between a lectin and natural chromophore. Furthermore, for the first time given the composition glicidic out of a sponge lectin. / Lectinas podem ser definidas como proteínas/glicoporteínas que reconhecem carboidratos de maneira específica, mas não participam do metabolismo dos mesmos e não pertencem a nenhuma das principais classes de imunoglobulinas. As lectinas são proteínas ubíquas, estando presente em todos os organismos conhecidos. Em células animais, lectinas têm sido encontradas no citoplasma, no núcleo e associadas a membranas das mais diversas organelas e nos mais variados tipos celulares. Tais lectinas animais podem ser classificadas em famílias distintas com base em suas características físico químicas, função e especialmente em sua identidade de estrutura primária e terciária. O objetivo deste trabalho foi purificar duas novas lectinas da esponja marinha Haliclona (Soestella) caerulea e caracterizar estruturalmente uma delas. Espécimes de H.caerulea foram coletados na praia do paracuru, Ceará. Duas lectinas (H-1 e H-3) foram isoladas por técnicas clássicas de química de proteínas. A estrutura primária de uma delas foi determinada por espectrometria de massas e RACE. A atividade tóxica das lectinas foi avaliada frente à náuplios de Artemia e cepas das bactérias Escherichia coli e Staphylococus aureus. H-1 e H-3 apresentaram características distinhas da lectina previamente isolada de H. caerulea. H-1 é uma proteína monomérica de aporoximadamente 40 kDa enquanto que H-3 é uma proteína trimérica com cadeias com massa aproximada de 9, 16 e 18 kDa. H-3 aglutina eritrócitos humanos do tipo A e B e foi inibida GalNAc e PSM, H-1 aglutina diversos grupos sanguineos e não pôde ser inibida por nenhum açúcar testado. H-1 foi tóxica a naúplios de Artemia (LC50=6,4 μg.mL-1) e H-3 foi considerada não tóxica (LC50=414,2 μg.mL-1). H-3 é uma proteína azul, pois interage com um cromóforo de 597 Da com absorção máxima a 620 nm. A estrutura primária de H-3 foi determinada e revelou-se única, não sendo conhecida nenhuma lectina com estrutura similar. H-3 apresenta um glicano híbrido composto por Hex7NAcHex7DeoxiHex2. A cadeia α de H-3 sofre um processamento proteolítico complexo que ainda não foi completamente elucidado. Além disso, H-3 foi cristalizada, mas não foi possível a obtenção de um padraão de difração que permita a resolução da estrutura. Em suma, duas novas lectinas foram isoladas e fora observado pela primeira vez a interação entre uma lectina e um cromóforo natural. Pela primeira vez também, fora determinada a composição glicídica de uma lectina de esponja.
97

Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião / Development and application system of flake-dissolved air flotation for treating wash water filter

Chaves, Karina Oliveira January 2012 (has links)
CHAVES, K. O. Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião. 2012. 125 f. Dissertação (Mestrado em Engenharia Civil) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T17:27:18Z No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:04:58Z (GMT) No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) / Made available in DSpace on 2012-09-25T14:04:58Z (GMT). No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) Previous issue date: 2012 / In Brazil the filter backwash wastewater is normally released in to the water resources without proper treatment, representing a potential danger to the environment. Thus, it is necessary to treat this wastewater in order to dispose it in accordance to federal and state environmental laws. Studies show that Dissolved Air Flotation (DAF) technology has been feasible for this purpose. It is believed that the incorporation of flocculation in curtains and air dissolved flotation system in the same unit can promote high efficiency and significant size reduction, which translates in a technological innovation: the Floculator - Dissolved Air Flotation (FFAD) unit. A FFAD pilot unit was built to evaluate the treatment of Gavião Water Treatment Plant filter backwash wastewater, owned by the Water and Wastewater Company of Ceará (CAGECE). This research had as main objective to quantify and verify the compliance of the filter backwash wastewater parameters to the Resolution No. 430/11 and 357/05 of CONAMA and Ordinance No. 154/2002 of SEMACE. Treatability studies were performed with filter backwash wastewater using Jartest to evaluate the influence of cationic polymer dosages and the feasibility of decreasing flocculation velocity gradients (35 to 5.6 s-1) in the FFAD. Experimental runs of the flocculation - flotation system were performed to evaluate the best polymer dosage and the process parameters such as recirculation rates (TR) and surface application rates (TAS). These parameters were compared by observing the lower residual turbidity and best removal efficiency in the clarified water (AC). The treated wastewater was again characterized using physicalchemical and bacteriological parameters and compared to the specific legislation. The results showed that the use of 1 mg.L-1 of polymer, recirculation rate of 15% and surface application rate of 57 m3.m-2.d-1, presented the highest turbidity efficiency removal (> 98%) and a very stable performance against sudden changes in the influent quality (94.4 to 410UT). It should be noted that the unity showed also a high average efficiency total coliforms removal (98.5%), apparent color removal (97.6%), DOC removal (92.6%), of aluminum (84.1%) removal and turbidity (99.2 %) removal. Given these results, it was concluded that the AC coming from the treatment of ALF by ETA WTP Gavião FFAD met the discharge parameters listed for water resources. / No cenário brasileiro, os resíduos de Estações de Tratamento de Água (ETAs) são normalmente lançados in natura em corpos hídricos, apresentando-se como potencialmente danosos ao meio ambiente, sendo necessário tratá-los para que sejam descartados conforme os aspectos legais. Estudos demonstram que a tecnologia da Flotação por Ar Dissolvido (FAD) tem sido viável para este fim. Acredita-se que a incorporação da floculação em cortinas numa mesma unidade de flotação possa promover elevada eficácia ao sistema, traduzindo-se como uma inovação tecnológica: o Floco-Flotador por Ar Dissolvido (FFAD). Uma unidade piloto de FFAD foi construída para o tratamento da água de lavagem dos filtros da ETA Gavião, pertencente à Companhia de Água e Esgoto do Ceará (CAGECE). Esta pesquisa teve como objetivo quantificar e verificar o atendimento da água de lavagem dos filtros (ALF) desta ETA e da água clarificada via FFAD aos padrões de lançamento de efluentes conforme as Resoluções nº 430/11 e 357/05 do CONAMA e Portaria nº 154/2002 da SEMACE. Estudos de tratabilidade da ALF em Jartest foram realizados para avaliar a influência da dosagem de polímeros catiônicos e a viabilidade de gradientes de velocidade decrescente (35 a 5,6 s-1) a serem empregados no equipamento de FFAD desenvolvido. Ensaios de flotação foram realizados a fim de avaliar a dosagem do polímero e os parâmetros de processo como taxas de recirculação (TR) e taxas de aplicação superficial (TAS). Após definidos estes parâmetros, ensaios de FFAD foram realizados em triplicata para coleta da AC a fim de compará-la com os principais padrões de lançamento de efluente em corpos hídricos classe II. Somente os parâmetros pH, Fluoreto, Amônia, E. coli e Sólidos dissolvidos da ALF atenderam aos padrões de lançamento. Ao aplicar polímero a 1 mg.L-1, taxa de recirculação de 15%, gradientes de velocidade decrescente (19,3 a 5,6 s-1), taxa de aplicação superficial de 57 m3.m-2.d-1 com tempo de detenção hidráulico de 22 minutos no FFAD, os resultados alcançaram elevada eficiência na remoção de turbidez (superior a 98%) mesmo enfrentando variações bruscas na qualidade da ALF (94,4 a 410 UT). Observou-se também significativa eficiência média na remoção de coliformes totais (98,5%), cor aparente (97,6%), DQO (92,6%) e remoção de alumínio (84,1%). Diante destes resultados, constatou-se que a ALF da ETA Gavião tratada via Floco-flotação por ar dissolvido atendeu aos referidos padrões de lançamento em corpos hídricos.
98

Cromatografia de permeação em gel em escala semi-preservativa aplicada à caracterização, purificação e fracionamento do ácido hialurônico produzido por cultivo de microorganismos / Gel permeation chromatography in semi-preparative scale apply to the characterization, purification and fractionation of microbial hyaluronic acid

Sousa, Anayla dos Santos 20 March 2007 (has links)
SOUSA, A. S. Cromatografia de permeação em gel em escala semi-preservativa aplicada à caracterização, purificação e fracionamento do ácido hialurônico produzido por cultivo de microorganismos. 94 f. 2007. Dissertação (Mestrado em Engenharia Química) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-22T12:38:11Z No. of bitstreams: 1 2007_dis_assousa.pdf: 1171864 bytes, checksum: 6a1b99afa67f29d1d865de66d7e597e6 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-03-28T19:12:59Z (GMT) No. of bitstreams: 1 2007_dis_assousa.pdf: 1171864 bytes, checksum: 6a1b99afa67f29d1d865de66d7e597e6 (MD5) / Made available in DSpace on 2016-03-28T19:12:59Z (GMT). No. of bitstreams: 1 2007_dis_assousa.pdf: 1171864 bytes, checksum: 6a1b99afa67f29d1d865de66d7e597e6 (MD5) Previous issue date: 2007-03-20 / Hyaluronic acid (HA) is a linear, unbranched polymer, composed by simple disaccharide units, whose molar mass may range in a wide interval of distribution (104-107 Da). It is used in pharmaceutical and cosmetic applications depending on its average molecular mass. The fractionation of macromolecules of the order of magnitude of the HA may be performed by gel permeation or size-exclusion chromatography (GPC). The objective of this work is to study the characterization, purification and fractionation of microbial HA by using GPC. HA was supplied by the Department of Biotechnological Processes (DPB/FEQ/UNICAMP), having been produced by microorganisms – Streptococcus zooepidemicus – in synthetic culture media. After being centrifuged from the fermentation broth, HA was precipitated with ethanol and then dissolved in saline solution, this pre-purification procedure being performed up to four times. The presence of proteic contaminants was identified by electrophoresis in polyacrylamide gel under denaturant conditions (SDS-PAGE) and quantified by the Bradford method. For the HA sample which had been precipitated in ethanol and dissolved in 0.1 M NaNO3 four times, protein concentration was found to be nearly 100 μg/mL. The sodium salt of commercial (Sigma Aldrich - EUA) microbial HA was used as standard in order to measure a calibration curve to assess HA concentration in the samples. For the sample precipitated in ethanol and dissolved in 0.1 M NaNO3 four times, AH concentration was found to be approximately 780 μg/mL. Molar mass distribution of HA samples was assessed by GPC, both in analytical and semi-preparative scale, using refractive index (RI) and UV/Vis (280 nm) detectors, 0.1 M NaNO3 as mobile phase, flow rate 0.8 mL/min and tracers dextran and pullulan (polymers of similar hydrodynamic volume as compared to HA) as molar mass standards. The samples showed molar mass distributions in the range of 103 to 107 Da, after being precipitated and dissolved four times. For these samples, the average molar mass was found to be in the order of magnitude of 105 Da. In the semi-preparative column Superose, it was possible to separate HA fractions, with molar mass above 105 Da, and free of proteic contaminants, in an elution interval of 10 minutes / O Ácido Hialurônico (AH) é um polímero linear, não ramificado, composto por unidades dissacarídicas simples, cuja massa molar pode se distribuir num largo intervalo (104-107 Da). É usado em aplicações farmacêuticas e cosméticas dependendo de sua massa molar média. A separação de macromoléculas da ordem de grandeza do AH é possível através da Cromatografia de permeação em gel (GPC). Este trabalho tem como objetivo estudar a caracterização, purificação e fracionamento do AH produzido por microorganismos, utilizando GPC. O AH, cedido pelo Departamento de Processos Biotecnológicos (DPB/FEQ/UNICAMP), foi obtido por cultivo de microorganismos - Streptococcus zooepidemicus - em meio de cultura sintético. Após centrifugação do caldo de fermentação, o AH foi precipitado com etanol e ressuspenso em solução salina, sendo esta etapa de pré-purificação executada até quatro vezes. A presença de contaminantes protéicos foi identificada por eletroforese em gel de poliacrilamida sob condições desnaturantes (SDS-PAGE) e quantificada pelo método de Bradford, obtendo-se 97,20 μg/mL, para a amostra de AH após quatro precipitações em etanol e ressuspensões em NaNO3 0,1 M. Para as determinações de concentração de AH nas amostras estudadas, utilizou-se o sal sódico de AH microbial comercial (Sigma Aldrich - EUA) como padrão. Quantificando-se a amostra de AH após quatro precipitações em etanol e ressuspensões em NaNO3 0,1 M, obteve-se 783,70 μg/mL. A distribuição da massa molar do AH foi avaliada por GPC, em escala analítica, utilizando coluna Shodex OHPak-SB806M-HQ e, em escala semi-preparativa, a coluna Superose 6, detectores de índice de refração e UV/Vis (280 nm), NaNO3 0,1 M como fase móvel, vazão de 0,8 mL/min e padrões de Dextrana e Pullulan (polímeros de volume hidrodinâmico semelhante ao AH) como marcadores de massa molar (5,2x103 - 7,9x106 Da e 5,8x103 – 8,53x105 Da, respectivamente). A amostra apresentou uma distribuição polimérica na faixa de 103 a 107 Da, após quatro precipitações em etanol e ressuspensões em NaNO3 0,1 M, sendo sua massa molar média da ordem de 105 Da. Foi possível separar frações de AH, acima de 105 Da, livre de contaminantes protéicos, num intervalo de aproximadamente 10 minutos, na coluna Superose 6
99

Proposta de modelo para escolha de tecnologias de tratamento de água em pequenas comunidades do semiárido / Proposed model for selection of water treatment technology for small communities of the semi-arid

Ponte, Fernando Victor Galdino 10 February 2011 (has links)
PONTE, F. V. G. Proposta de modelo para escolha de tecnologias de tratamento de água em pequenas comunidades do semiárido. 2011. 223 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-05T16:55:41Z No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-17T16:35:54Z (GMT) No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) / Made available in DSpace on 2016-05-17T16:35:54Z (GMT). No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) Previous issue date: 2011-02-10 / The water supply systems in Ceará semiarid are deficient with regard to water quality. The water treatment in communities are not being very efficient, since there is no standardization of water treatment plants in relation to the quality of the raw water that is captured. Therefore, it was developed a simplified model of choice selection of water treatment technologies for small communities, which was developed using Excel 2007, where you can make a correct choice of the treatment plant that will supply water to a location. The model consists of two steps. In the first stage are the criteria for exclusion, since it is a simplified model and parameters such as hardness, chloride, fluoride, among others need to be well analyzed, due to their treatment are not feasible for small rural communities and are not in the model‟s result. The second step is the selection of technologies for water treatment itself, on which selecting the source and its characteristics, the model will be able to bring the best result for an effective treatment. In addition to the model‟s results are the hydraulic design and the plant water treatment plants chosen. The technologies used were the Complete Cycle, the Direct Ascendant Filtration, the Double Filtration and Oxidation followed by rapid Ascendant Filtration. The selection criteria were included by a bibliographic review of established authors in water treatment and the criteria for choosing the technology that removes iron were developed in the pilot plant at ETA GAVIÃO. / Os pequenos sistemas de abastecimento de água no semiárido cearense apresentam uma deficiência no que diz respeito à qualidade. O tratamento da água nestas comunidades não está sendo bem eficiente, já que não há uma metodologia para escolha da tecnologia apropriada para o tratamento de água em função da qualidade da água bruta. Tendo em vista essa problemática, foi desenvolvido um modelo simplificado de escolha de tecnologia de tratamento de água para pequenas comunidades, utilizando o Excel 2007. O modelo tem duas etapas: Na primeira, encontram-se os critérios de exclusão, parâmetros tais como a dureza, os cloretos, o flúor, dentre outros. Devido seu tratamento ser tecnicamente inviável em pequenas comunidades rurais, não foram considerados no resultado do modelo. A segunda etapa é a de seleção das tecnologias de tratamento de água propriamente dito, onde ao se selecionar o manancial e algumas de suas características, o modelo será capaz de trazer o melhor sistema para um tratamento eficiente. Juntamente com o resultado do modelo, encontram-se os dimensionamentos hidráulicos e as plantas das estações de tratamento de água propostas. As tecnologias usadas foram o Ciclo Completo, a Filtração Direta Ascendente, a Dupla Filtração e a Oxidação seguida de Filtração rápida Ascendente. Os critérios de seleção foram definidos através de revisão bibliográfica, com exceção dos critérios para escolha da tecnologia para remoção de ferro, que foram encontrados em corridas experimentais realizadas na instalação piloto existente na ETA GAVIÃO.
100

Uso de um reator anaeróbio de manta de lodo e fluxo ascendente (UASB) na remoção de sulfato, DQO e das espécies metálicas níquel (NI2+), zinco (ZN2+) e cobre (CU2+) / Using an anaerobic sludge blanket and upflow (UASB) in removing sulphate, COD, metal species nickel (Ni 2+), zinc (Zn 2+) and copper (CU2 +)

Albuquerque, Vinicius Farias de 28 August 2009 (has links)
ALBUQUERQUE, V. F. Uso de um reator anaeróbio de manta de lodo e fluxo ascendente (UASB) na remoção de sulfato, DQO e das espécies metálicas níquel (NI2+), zinco (ZN2+) e cobre (CU2+). 2009. 91 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-29T14:35:55Z No. of bitstreams: 1 2009_dis_vfalbuquerque.pdf: 1470923 bytes, checksum: 47fb93ddf051bd3d2704da63be6774eb (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-25T18:46:01Z (GMT) No. of bitstreams: 1 2009_dis_vfalbuquerque.pdf: 1470923 bytes, checksum: 47fb93ddf051bd3d2704da63be6774eb (MD5) / Made available in DSpace on 2016-05-25T18:46:01Z (GMT). No. of bitstreams: 1 2009_dis_vfalbuquerque.pdf: 1470923 bytes, checksum: 47fb93ddf051bd3d2704da63be6774eb (MD5) Previous issue date: 2009-08-28 / This work had the objective of analyze the efficiency of the use of an anaerobic upflow sludge bed reactor (UASB) inoculated with methanogenic sludge proceeding from a beer industry in a treatment of a synthetic effluent with sulfate and subsequently added with the metal ions zinc (Zn2+), nickel (Ni2+) and cooper (Cu2+). The reactor was operated with a hydraulic retention time (HRT) of 18 hours and a flow of 14,9 L/day with ethanol as electron donor. The organic loading rate (OLR) was 1,5 kgDQO/m3.d during the whole running period of the reactor. The continuous flow experiment was divided into four stages after stable conditions had been achieved. At stages 1 (DQO/SO4 2- = 2,26), 2 (DQO/SO4 2- = 1,13) e 3 (DQO/SO4 2- = 0,57) the influent was added with sulfate at different concentrations allowing the analysis of the reactor behavior under different relations DQO/SO4 2-. Finally, at the stage four the metals ions were added. The stage 1 (sulfate concentration of 500 mg/L) showed average removal efficiencies of COD and sulfate of 83,61% and 67,00%, respectively, in addiction to show that the reactor remained stable during this period. Now, in step 2 (sulfate concentration of 1000 mg/L), the reactor was undergoing a period of instability due to shock load caused by new sulfate concentration, but still showed good average removal efficiencies of COD (70%) and sulfate (62%). Step 3 (sulfate concentration of 2000 mg/L) showed that under low relations DQO/SO4 2- income ends up falling, mainly due to lack of electron donor for sulfate reduction. The average removal efficiencies of COD and sulfate were 62% and 44% respectively. In step 4, was added the metal ions, initially at a concentration of 50 mg/L, there was obtained as average removal efficiencies for Zn2+, Ni2+,and Cu2+ the following values, respectively 99.17% and 99.15% 99.90%. For the influent concentration of metal ions of 150 mg/L the average removal efficiencies of nickel, zinc and copper were 99.4%, 99.5% and 99.8%, respectively. Samples of sludge taken from different heights of the reactor were also analysed to determine the distribution of metals along the length of reactor. The overall results showed good removal efficiencies of COD and sulphate, and show removal efficiencies of initial concentrations of metal ions above 99%, demonstrating the feasibility of using biological reduction of sulfate in the treatment of effluents containing high concentrations of organic matter, sulfate and heavy metals. / Este trabalho teve como objetivo analisar a eficiência do uso de um reator anaeróbio de fluxo ascendente e manta de lodo inoculado com lodo metanogênico proveniente de uma indústria de cerveja no tratamento de efluente sintético contendo um meio basal constituído de sulfato e posteriormente adicionado dos íons metálicos zinco (Zn2+), níquel (Ni2+) e cobre (Cu2+). O reator foi operado com um tempo de detenção hidráulico (TDH) de 18 horas e vazão de 14,9 L/dia, com o etanol como doador de elétrons. A carga orgânica volumétrica (COV) foi de 1,5 kgDQO/m3.d durante todo período de funcionamento do reator. O experimento em fluxo contínuo foi dividido em quatro etapas após a obtenção de condições estáveis de operação. Nas etapas 1 (DQO/SO4 2- = 2,26), 2 (DQO/SO4 2- = 1,13) e 3 (DQO/SO4 2- = 0,57) o afluente foi adicionado de sulfato em diferentes concentrações, permitindo a análise do comportamento do reator sob diferentes relações DQO/SO4 2-. Finalmente, na etapa quatro foram adicionados os íons metálicos. A etapa 1 (concentração de sulfato de 500 mg/L) mostrou eficiências médias de remoção de DQO e sulfato de 83,61% e 67,00%, respectivamente, além de mostrar que o reator se manteve estável durante este período. Já na etapa 2 (concentração de sulfato de 1000 mg/L), o reator passou por um período de instabilidade devido ao choque de carga ocasionado pela nova concentração de sulfato, mas ainda apresentou boas eficiências médias de remoção de DQO (70%) e sulfato (62%). A etapa 3 (concentração de sulfato de 2000 mg/L) mostrou que sob relações DQO/SO4 2- baixas o rendimento acaba caindo, principalmente devido à falta de doador de elétrons para a redução de sulfato. As eficiências médias de remoção de DQO e sulfato foram de 62% e 44%, respectivamente. Na etapa 4, adicionou-se os íons metálicos inicialmente na concentração de 50 mg/L, obtendo-se como eficiências médias de remoção para o Zn2+, Ni2+ e Cu2+ os seguintes valores, respectivamente: 99,17%, 99,15% e 99,90%. Para a concentração afluente dos íons metálicos de 150 mg/L as eficiências médias de remoção de níquel, zinco e cobre foram de 99,4%, 99,5% e 99,8%, respectivamente. Também foram analisadas amostras de lodo retiradas de diferentes alturas do reator para verificar a distribuição dos metais ao longo da extensão do reator. Os resultados gerais mostraram boas eficiências de remoção de DQO e sulfato, além de mostrarem eficiências de remoção das concentrações iniciais dos íons metálicos acima de 99%, mostrando a viabilidade do uso da redução biológica de sulfato no tratamento de efluentes contendo altas concentrações de matéria orgânica, sulfato e metais pesados.

Page generated in 0.0642 seconds