• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • Tagged with
  • 63
  • 63
  • 21
  • 18
  • 15
  • 15
  • 15
  • 12
  • 12
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação de sistemas de captação de imagem com fonte de raios X em peças de ferro fundido

Ruy de Macedo Minari 17 December 2009 (has links)
Atualmente, no Brasil e exterior, as avaliações de peças industriais nos sistemas radiográficos são feitas durante ou após a fabricação de maneira a verificar a integridade interna das mesmas. Esses ensaios são de suma importância para atender os requisitos de normas, de projetos e de utilização, garantindo a qualidade e confiabilidade, reduzindo os riscos de quebra de equipamentos e para vidas humanas. Os ensaios radiográficos e fluoroscópicos industriais são métodos de ensaios não destrutivos que se baseiam na absorção diferenciada da radiação penetrante pela peça que está sendo ensaiada. Essa variação na quantidade de radiação absorvida é detectada através de um meio que irá nos indicar, entre outras coisas, a existência de uma descontinuidade interna. Este trabalho tem por objetivo fornecer uma base de dados concreta, baseada em experimentos práticos e reais, que gere conhecimento de suporte ao responsável pela instalação radioativa neste momento decisório através da comparação das diversas técnicas no ensaio de peças de ferro fundido nodular. Os ensaios de campo foram executados com equipamentos de raios X de energia máxima de 320 kV com potencial constante, em 15 peças de ferro fundido nodular, utilizando 05 técnicas de captação de imagem, que são: radiografia convencional, radiografia computadorizada, radiografia digital, fluoroscopia analógica e fluoroscopia digital. As radiografias resultantes dos diversos tipos de captação de imagem foram laudadas por inspetores qualificados pela norma de qualificação de pessoal na área aeronáutica (NAS 410, 2008), e os resultados dos ensaios, para verificar a melhor aderência de cada sistema de imagem com a Norma Nuclear CNEN-NE-3.01, onde qualquer atividade envolvendo radiação deve ser justificada em relação a outras alternativas e produzir um benefício líquido positivo. O nível da aceitabilidade das descontinuidades para que o inspetor possa laudar as radiografias é um acordo entre cliente e fornecedor e, neste caso, foi determinado o nível de qualidade de imagem de 2:4T um nível adequado de qualidade, 2:2T um nível bom e 2:1T um nível ótimo de qualidade de imagem. / Now a days, in Brazil and exterior, the evaluations of industrial parts through X-rays systems are made during or after producing verifying the internal integrity of them. Those testing are sum important for the norms requirements, of projects and utilization, guaranteeing the quality and reliability, reducing the equipment break risks and for human lives. The radiográficos and fluoroscópicos industrial testing are methods of non destructive testing that is based on the differentiated absorption of penetrating radiation by the part that is being tested. That variation in the radiation quantity absorbed is detected through an indicate environment, between other things, the existence of an internal descontinuidade. This paper has for objective supply a base of concrete facts, based in real and practical experiments, that manages knowledge of support to the responsible for the radioactive installation in this decisive moment through the comparison of diverse techniques tested in nodular cast iron parts. The field practice were performed with equipment of X-rays 320 kV maximum energy with constant potential, in 15 pieces nodular cast iron, utilizing 05 image collection techniques, that are: conventional x-ray, x-ray computerized, digital x-ray, fluoroscopia analog and fluoroscopia digital. The resultant x-rays of the diverse image collection kinds were attested by inspectors qualified by t personals qualification norm in the aeronautic area (IN THE 410, 2008), and the results of the testing, verify the better adhesion of each system of image to the Nuclear Norm CNEN-NE-3.01, where any activity involving radiation should be justified regarding other alternatives and produce a positive liquid benefit. The level of the acceptability of the descontinuidades for that the inspector be able to laudar the x-rays is an agreement between client and supplying and, in that case, was determined the image quality level of 2:4T, an adequate level of quality is 2:2T and great level of quality of 2:1T.
62

Efetividade dos filtros empregados em imagens radiográficas digitais na detecção dos quadros pulmonares de cães e gatos / Effectivity of the filters used in radiographic digital imaging in the detection of pulmonary patterns in dogs and cats

Carina Outi Baroni 10 December 2012 (has links)
A transição do sistema radiográfico convencional para os sistemas radiográficos digitais, ao longo de vinte anos, tem transformado as salas de laudos nos Serviços de Diagnóstico por Imagem tanto na Medicina quanto na Medicina Veterinária. Atualmente, com a introdução do sistema radiográfico computadorizado na rotina de alguns hospitais e laboratório de imagem, o uso das ferramentas do pós-processamento tem se tornado mais freqüente. Diante das vantagens e desvantagens destas ferramentas e da escassez de trabalhos a cerca dos filtros utilizados em imagens radiográficas digitais, o objetivo deste trabalho foi testar o uso dos filtros convencional, realce de borda e invertido, assim como a associação deles na detecção dos padrões pulmonares de cães e gatos. Foram selecionados 40 exames radiográficos do tórax de cães e gatos contendo as três projeções de eleição. Três observadores com diferentes graus de experiência e familiaridade com o sistema radiográfico computadorizado analisaram os filtros individualmente e depois em associação na detecção geral dos padrões pulmanres e individualmente. Obteve-se melhores valores de sensibilidade e especificidade, em geral, quando os observadores experientes utilizaram os três filtros em associação e, para o iniciante, os melhores resultados da sensibilidade e especificidade, em geral, foram no filtro convencional. Os resultados deste trabalho permitiram concluir que houve diferença estatística entre os observadores com distintos graus de experiência e familiaridade com o sistema digital. E que o uso em associação dos filtros pode incrementar o desempenho do radiologista na avaliação radiográfica do parênquima pulmonar. / The transition of the conventional radiographic system to the digital one has been transforming the radiographic routine human and veterinary medicine over the last twenty years. Currently, the introduction of the computed radiography system in some hospitals and imaging services has increased the use of post processing tools. Considering the advantages and disadvantages of these tools and the lack of knowledge about the filters used in digital radiographic images, the aim of this study was to test efficacy of the standard, edge enhancement and gray scale reversed filters and their association to detect pulmonary patterns of cats and dogs. This work selected forty canine and feline sets of thoracic radiographs, including three projections. Three different observers with different degrees of experience and familiarity with the computed radiographic system analyzed the filters individually and then associated in order to detect pulmonary patterns. The best results in sensibility and specificity were related to the more experienced observers using the three associated filters. However, for the beginner, the best sensibility and specificity results was reached with the use of the standard filter in general results. In conclusion were statistical differences between more experienced and familiarized observers with the digital system and the use of filters can increase the radiologist performance when evaluating the pulmonary patterns on the radiography.
63

Avaliação de materiais usando a radiografia computadorizada (CR) empregando um acelerador linear e cobalto - 60 como fontes de altas energias / Evaluation of materials using computed radiography (CR) employing a linear accelerator and cobalt - 60 as source of high energy

Heleno Ribeiro Simões 15 December 2012 (has links)
Nas construções de caldeiras de força, vasos de pressão e outros tipos de equipamentos para os diversos segmentos industriais têm exigido da engenharia de materiais um desenvolvimento tecnológico para melhores processos na obtenção de materiais fundidos, forjados, laminados, e outros. Desenvolver recursos tecnológicos que minimizem a presença de imperfeições que possam comprometer a integridade estrutural dos equipamentos que operam com pressão tem sido uma busca constante tanto nas usinas como nas indústrias de bens de capital nas fases das construções. Uma construção implica em seleção de materiais, projeto, fabricação, exames, inspeção, testes, certificação e dispositivos de alívio que atendam aos requisitos dos códigos e normas. Estes requisitos estão cada vez maiores e estabelecem limites para a existência destas imperfeições vão de encontro à necessidade de lançar mão de métodos de ensaios não destrutivos que permitam sempre a melhor probabilidade de detecção. Os processos de controle da qualidade têm buscado por meio das novas tecnologias aumentarem a sua sensibilidade, visando à detecção de descontinuidades que hoje são detectadas pelos métodos convencionais. Em termos de ensaios não destrutivos, as exigências para o ensaio radiográfico convencional estão no limite da sensibilidade dos filmes radiográficos industriais disponíveis, além do compromisso de buscar um tempo de exposição menor ser sempre um fator importante a ser considerado na qualidade, segurança e produtividade tanto na fábrica como no campo. O objetivo deste trabalho foi estudar e avaliar a técnica de radiografia computadorizada (RC) em relação à radiografia convencional para inspeção dos materiais, utilizando os parâmetros de avaliação, tais como, relação sinal ruído, resolução espacial, ferramentas para detectabilidade, sensibilidade ao contraste e tons de cinza, que são aplicáveis nas avaliações de imagens digitais. Para a avaliação da técnica de radiografia industrial digital foi utilizado um corpo-de-prova fabricada pelo processo de fundição com espessura de 75 a 150 mm, com defeitos típicos do processo. O corpo-de-prova foi radiografado com a técnica convencional e digital. Na técnica convencional foram utilizados os filmes radiográficos industriais tipos I e II do ASTM E 1815, um acelerador linear Varian modelo Linatron 400 de 4 MeV e duas fontes de Cobalto-60 com atividades diferentes. Na técnica computadorizada foram utilizados as mesmas fontes de radiação, uma placa de fósforo denominada IPX e um equipamento CR-50P ambos da GE IT. Pelos resultados obtidos pode-se verificar que a radiografia digital com os equipamentos avaliados, atende satisfatoriamente os códigos e normas que são utilizadas na avaliação de peças fundidas. A técnica mostrou-se mais qualitativa quando na avaliação das descontinuidades localizadas nas seções críticas, pois o sistema RC possibilita a utilização de ferramenta de perfil de linha que fornece os valores de nível de cinza ao longo de uma trajetória linear demarcada na área da imagem da descontinuidade. Com isto, mesmo em poucos experimentos e um único sistema de RC pode-se concluir que a técnica é bastante vantajosa na detecção de descontinuidades nos processos de fabricação e que atendeu tanto os requisitos do ASTM E 272 para o cobre ou o ASME Seção VIII Divisão 1, Apêndice 7 que referenciam os padrões radiográficos conforme as normas ASTM E-186 e ASTM E-280 para aços fundidos. / In the constructions of power boilers, pressure vessels and other equipment for several industries has required the development of materials engineering technology for better processes in obtaining materials cast, forged, rolled, and others. Develop technological resources that minimize the presence of imperfections that could compromise the structural integrity of the equipment operating pressure has been a constant search both in plants and in capital goods industries phases of construction. A construction involves materials selection, design, fabrication, testing, inspection, testing, certification, and relief devices that meet the requirements of codes and standards. These requirements are increasing and establish limits for the existence of these imperfections go against the need to resort to non-destructive testing methods that enable always the best probability of detection. The processes of quality control have sought through new technologies increase their sensitivity in order to detect discontinuities of today are detected by conventional methods. In terms of non-destructive testing, requirements for conventional radiographic testing are at the limit of sensitivity of available industrial radiographic films, besides the commitment to seek a lower exposure time is always an important factor to be considered in quality, safety and productivity both in the factory and in the field. The aim of this work was to study and evaluate the technical radiography Computed (RC) compared to conventional radiography for inspection of materials, using evaluation parameters such as signal to noise ratio, spatial resolution, and tools for detectability, contrast sensitivity and grayscale, which apply in evaluations of digital images. For the evaluation of industrial radiography technique it was used a test specimen manufactured by the casting process with thickness from 75 to 150 mm, with typical defects in the process. The test specimen was X-rayed with the conventional and digital techniques. In the conventional technique were used industrial radiographic films types I and II to ASTM E 1815, a linear accelerator Varian model 400 Linatron 4 MeV and two cobalt-60 sources with different activities. In the technique computed were used the same radiation source, a phosphor plate IPX and an apparatus called CR-50P both GE IT. From the results it can be seen that with digital radiography equipment evaluated satisfactorily meets the codes and standards that are used in the evaluation of castings. The technique was more qualitative evaluation when the discontinuities located in critical sections for the system to use RC allows tool profile line shows values of gray level along a linear path demarcated in the image area discontinuity. With this, even in a few experiments a single system and RC can be concluded that the technique is quite advantageous in the detection of discontinuities in the manufacturing processes and that both met the requirements of ASTM E 272 for copper or ASME Section VIII Division 1, Appendix 7 that reference radiographic patterns according to ASTM E-186 and ASTM E-280 for steel castings.

Page generated in 0.1183 seconds