• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da acurácia dos métodos radiográficos convencional e digital direto na análise da extensão de lesões de cárie oclusais em molares decíduos. estudo in vitro / Accuracy evaluation of conventional and direct digital radiographic methods in the analysis of occlusal carious lesions extension in primary molars. An In Vitro Study

Silva, Paulo Renato Dias da 28 March 2008 (has links)
Esta pesquisa in vitro, avaliou comparativamente a acurácia do diagnóstico do método radiográfico digital com o método radiográfico convencional, na detecção de lesões de cárie oclusal em molares decíduos. O material foi composto por 55 dentes posteriores decíduos, que apresentavam pigmentações e pelo menos um sítio suspeito de lesão de cárie oclusal, sem restaurações e superfícies sem selantes. As radiografias digitais foram executadas com o sistema Dixi3 (Planmeca, Helsink, Finland) e as radiografias convencionais com o filme Insight (Kodak Eastman Co., EUA), ambas de modo padronizado, em idênticas condições geométricas. As imagens foram avaliadas individualmente por três radiologistas, em ideais condições de interpretação radiográfica e sem acesso aos recursos de manipulação de imagens do sistema digital. Os achados foram classificados de acordo com o seguinte critério: 0 - ausência de radiolucidez no esmalte, 1- radiolucidez confinada ao esmalte, 2- radiolucidez no esmalte até o limite dentina-esmalte, 3- radiolucidez no esmalte e na metade mais externa da dentina, 4- radiolucidez no esmalte alcançando a metade mais interna da dentina. O padrão ouro foi obtido pelo estudo histológico. Os dados foram analisados através do teste de Freidman (P <= 0,05). Os resultados obtidos com os filmes radiográficos convencionais foram similares aos resultados obtidos com as radiografias digitais diretas e o padrão ouro, porém os resultados obtidos com o sistema radiográfico digital foram significativamente menores que o histológico. Nas condições deste estudo, concluímos que o método de radiografia digital subestimou a extensão das lesões de cárie oclusal em molares decíduos. / This in vitro research, evaluated the accuracy of the direct digital radiographic method compared to the conventional radiographic method in the analysis of the extension of occlusal carious lesions in primary molars. The material was composed by 55 primary molars presenting pigmentation and, at least, one suspect site of occlusal carious lesion, these teeth had neither restoration nor surfaces with sealant. Digital radiographs were obtained with the Dixi3 system (Planmeca, Helsink, Finland) and the conventional radiographs with the Insight film (Kodak Eastman Co., USA), both in standard form and identical geometrical conditions. The images were evaluated individually by three radiologists, in ideal conditions for radiographic interpretation and with no access to the resources of imaging manipulation from the digital system. The results were rated according to the following criteria: 0 - absence of radiolucence in the enamel: 1 - radiolucence confined to the enamel, 2 - radiolucence in the enamel to the limit dentine-enamel, 3 - radiolucence in the enamel and in the half outer part of the dentine, 4 - radiolucence in the enamel reaching to the half inner part of the dentine. The gold standard was obtained by histological study. Data were compared by the Friedman`s test (P <= 0.05). The results obtained with the conventional radiographic films were similar to those obtained with both direct digital radiographs and gold standard; however, the results obtained with the digital radiographic system were significantly lower than those observed in the histological analysis. In the conditions of this study, it was concluded that the direct digital radiographic method significantly underestimate the extension of the occlusal caries lesions in primary molars.
2

Performance diagnostica da RM na avaliação de reações periosteais em sarcomas ósseos utilizando a radiografia convencional como padrão de referência / Diagnostic performance of MRI in the assessment of periosteal reactions in bone sarcomas using radiography as the reference standard

Sá Neto, José Luiz de 17 September 2015 (has links)
Objetivo: Avaliar o desempenho diagnóstico da ressonância magnética (RM) na avaliação da presença de reação periosteal (RP) em sarcomas primários de ossos longos, utilizando a radiologia convencional (RC) como padrão de referência. Materiais e Métodos: Estudo retrospectivo com aprovação do Comitê de Ética Institucional. A partir do Sistema de Informática da Radiologia (RIS) e do Sistema de Arquivo de Imagens do HCRP identificamos retrospectivamente os casos de 42 pacientes consecutivos (idade média de 22 anos, sendo 20 homens, 22 mulheres) que realizaram tratamento de osteossarcoma ou sarcoma de Ewing no HCRP e cujos exames de RM e RC estavam disponíveis para reavaliação. Foram incluídos apenas casos de tumores de ossos longos e com confirmação histopatológica. Três radiologistas musculoesqueléticos avaliaram retrospectivamente a presença ou ausência de RP e identificaram para cada caso a ausência ou presença de cada um dos padrões de RP agressiva nas imagens da RC e da RM: Triângulo de Codman, multilamelada e espiculada. A classificação dos Radiologistas foi realizada de forma independente e às cegas em relação ao diagnóstico definitivo e em relação as demais avaliações realizadas. As leituras das imagens de RM e RC realizadas pelo mesmo observador tiveram um intervalo de pelo menos três meses entre elas. Usamos as leituras dos três observadores para avaliar a confiabilidade interobservador por meio do coeficiente Kappa. Finalmente uma análise consensual das leituras realizadas pelos três observadores tanto para a RC quanto para a RM foi utilizada para calcular o desempenho diagnóstico da ressonância magnética na detecção de RP e na classificação de cada padrão agressivo de RP. O radiologista com maior tempo de experiencia fez a classificação consensual da presença ou ausência de cada subtipo de reação periosteal nos casos em que houve discordância entre os observadores. 8 Resultados: A concordância interobservador para a detecção de RP foi quase perfeita para a RC e substancial a quase perfeita para a RM. A concordância interobservador para a classificação dos diferentes padrões de RP foi moderada a substancial para a presença do triângulo de Codman. A avaliação dos padrões de RP multilamelada e espiculada foi menos consensual entre os radiologistas tanto para RC quanto para a RM. O diagnóstico por RM e RC e a classificação de cada RP agressiva foram estatisticamente associadas com o diagnóstico por RC (p <0,05). A RM mostrou alta especificidade e valor preditivo negativo elevado, mas moderada sensibilidade na detecção de reações periosteais quando comparada com a RC. Conclusão: Nossos resultados sugerem que a detecção de RP por meio da RM e da RC apresenta alta reprodutibilidade. A RM mostrou alta especificidade e sensibilidade moderada para a identificação de RP em comparação com a RC. No entanto, a reprodutibilidade da classificação em diferentes padrões de RP agressivas foi relativamente baixo, tanto para RC quanto para RM em relação às RPs multilameladas e espiculadas. / Objective - To evaluate the diagnostic performance of magnetic resonance imaging (MR) assessing the presence of periosteal reaction (PR) in primary long bone sarcomas using conventional radiography (CR) as the reference standard. Materials and methods After institutional board approval, we retrospectively reviewed the MRI and conventional radiographies of 42 consecutive patients (mean age 22 years, 20 men, 22 women). We included only cases of osteosarcoma or Ewings sarcoma in the long bones with histopathological confirmation. Three experienced musculoskeletal radiologists retrospectively evaluated the presence or absence of periosteal reaction and each pattern of aggressive periosteal reaction in radiographs and MR imaging: Codman triangle, multi layered and spiculated. Radiologists classification was blinded and independent. The readings of the MR images and CR performed by the same observer had an interval of at least three months between them. We use the readings of three observers to assess the interobserver reliability through the Kappa coefficient. Finally a consensus analysis of readings performed by the three observers for both CR and MR was used to calculate the diagnostic performance of MR in detecting PR and classification of each PR aggressive pattern. The radiologist with greater experience made the consensus score of the presence or absence of each periosteal reaction subtype where there was disagreement among observers. 10 Results The interobserver agreement for the detection of PR was almost perfect for the CR and substantial to almost perfect for the MR. The interobserver agreement for the classification of different patterns of PR was moderate to substantial for the presence of Codman triangle. The evaluation of PR multilammelated standards and spiculated was less consensus among radiologists as well for CR as to MR. The diagnostic and the classification of each aggressive PR with MR imaging and with CR were statistically associated with the diagnosis by CR (p <0.05). MR showed high specificity and high negative predictive value, but moderate sensitivity in detecting periosteal reactions when compared to the CR. Conclusions Our results suggest that detection of PR through MR and CR has high reproducibility. MRI showed high specificity and moderate sensitivity for the identification of PR compared to CR. However, the reproducibility of the classification into different patterns of aggressive PRs was relatively low for both CR and for MR regarding the multilamellated and spiculated PRs.
3

Avaliação da acurácia dos métodos radiográficos convencional e digital direto na análise da extensão de lesões de cárie oclusais em molares decíduos. estudo in vitro / Accuracy evaluation of conventional and direct digital radiographic methods in the analysis of occlusal carious lesions extension in primary molars. An In Vitro Study

Paulo Renato Dias da Silva 28 March 2008 (has links)
Esta pesquisa in vitro, avaliou comparativamente a acurácia do diagnóstico do método radiográfico digital com o método radiográfico convencional, na detecção de lesões de cárie oclusal em molares decíduos. O material foi composto por 55 dentes posteriores decíduos, que apresentavam pigmentações e pelo menos um sítio suspeito de lesão de cárie oclusal, sem restaurações e superfícies sem selantes. As radiografias digitais foram executadas com o sistema Dixi3 (Planmeca, Helsink, Finland) e as radiografias convencionais com o filme Insight (Kodak Eastman Co., EUA), ambas de modo padronizado, em idênticas condições geométricas. As imagens foram avaliadas individualmente por três radiologistas, em ideais condições de interpretação radiográfica e sem acesso aos recursos de manipulação de imagens do sistema digital. Os achados foram classificados de acordo com o seguinte critério: 0 - ausência de radiolucidez no esmalte, 1- radiolucidez confinada ao esmalte, 2- radiolucidez no esmalte até o limite dentina-esmalte, 3- radiolucidez no esmalte e na metade mais externa da dentina, 4- radiolucidez no esmalte alcançando a metade mais interna da dentina. O padrão ouro foi obtido pelo estudo histológico. Os dados foram analisados através do teste de Freidman (P <= 0,05). Os resultados obtidos com os filmes radiográficos convencionais foram similares aos resultados obtidos com as radiografias digitais diretas e o padrão ouro, porém os resultados obtidos com o sistema radiográfico digital foram significativamente menores que o histológico. Nas condições deste estudo, concluímos que o método de radiografia digital subestimou a extensão das lesões de cárie oclusal em molares decíduos. / This in vitro research, evaluated the accuracy of the direct digital radiographic method compared to the conventional radiographic method in the analysis of the extension of occlusal carious lesions in primary molars. The material was composed by 55 primary molars presenting pigmentation and, at least, one suspect site of occlusal carious lesion, these teeth had neither restoration nor surfaces with sealant. Digital radiographs were obtained with the Dixi3 system (Planmeca, Helsink, Finland) and the conventional radiographs with the Insight film (Kodak Eastman Co., USA), both in standard form and identical geometrical conditions. The images were evaluated individually by three radiologists, in ideal conditions for radiographic interpretation and with no access to the resources of imaging manipulation from the digital system. The results were rated according to the following criteria: 0 - absence of radiolucence in the enamel: 1 - radiolucence confined to the enamel, 2 - radiolucence in the enamel to the limit dentine-enamel, 3 - radiolucence in the enamel and in the half outer part of the dentine, 4 - radiolucence in the enamel reaching to the half inner part of the dentine. The gold standard was obtained by histological study. Data were compared by the Friedman`s test (P <= 0.05). The results obtained with the conventional radiographic films were similar to those obtained with both direct digital radiographs and gold standard; however, the results obtained with the digital radiographic system were significantly lower than those observed in the histological analysis. In the conditions of this study, it was concluded that the direct digital radiographic method significantly underestimate the extension of the occlusal caries lesions in primary molars.
4

Performance diagnostica da RM na avaliação de reações periosteais em sarcomas ósseos utilizando a radiografia convencional como padrão de referência / Diagnostic performance of MRI in the assessment of periosteal reactions in bone sarcomas using radiography as the reference standard

José Luiz de Sá Neto 17 September 2015 (has links)
Objetivo: Avaliar o desempenho diagnóstico da ressonância magnética (RM) na avaliação da presença de reação periosteal (RP) em sarcomas primários de ossos longos, utilizando a radiologia convencional (RC) como padrão de referência. Materiais e Métodos: Estudo retrospectivo com aprovação do Comitê de Ética Institucional. A partir do Sistema de Informática da Radiologia (RIS) e do Sistema de Arquivo de Imagens do HCRP identificamos retrospectivamente os casos de 42 pacientes consecutivos (idade média de 22 anos, sendo 20 homens, 22 mulheres) que realizaram tratamento de osteossarcoma ou sarcoma de Ewing no HCRP e cujos exames de RM e RC estavam disponíveis para reavaliação. Foram incluídos apenas casos de tumores de ossos longos e com confirmação histopatológica. Três radiologistas musculoesqueléticos avaliaram retrospectivamente a presença ou ausência de RP e identificaram para cada caso a ausência ou presença de cada um dos padrões de RP agressiva nas imagens da RC e da RM: Triângulo de Codman, multilamelada e espiculada. A classificação dos Radiologistas foi realizada de forma independente e às cegas em relação ao diagnóstico definitivo e em relação as demais avaliações realizadas. As leituras das imagens de RM e RC realizadas pelo mesmo observador tiveram um intervalo de pelo menos três meses entre elas. Usamos as leituras dos três observadores para avaliar a confiabilidade interobservador por meio do coeficiente Kappa. Finalmente uma análise consensual das leituras realizadas pelos três observadores tanto para a RC quanto para a RM foi utilizada para calcular o desempenho diagnóstico da ressonância magnética na detecção de RP e na classificação de cada padrão agressivo de RP. O radiologista com maior tempo de experiencia fez a classificação consensual da presença ou ausência de cada subtipo de reação periosteal nos casos em que houve discordância entre os observadores. 8 Resultados: A concordância interobservador para a detecção de RP foi quase perfeita para a RC e substancial a quase perfeita para a RM. A concordância interobservador para a classificação dos diferentes padrões de RP foi moderada a substancial para a presença do triângulo de Codman. A avaliação dos padrões de RP multilamelada e espiculada foi menos consensual entre os radiologistas tanto para RC quanto para a RM. O diagnóstico por RM e RC e a classificação de cada RP agressiva foram estatisticamente associadas com o diagnóstico por RC (p <0,05). A RM mostrou alta especificidade e valor preditivo negativo elevado, mas moderada sensibilidade na detecção de reações periosteais quando comparada com a RC. Conclusão: Nossos resultados sugerem que a detecção de RP por meio da RM e da RC apresenta alta reprodutibilidade. A RM mostrou alta especificidade e sensibilidade moderada para a identificação de RP em comparação com a RC. No entanto, a reprodutibilidade da classificação em diferentes padrões de RP agressivas foi relativamente baixo, tanto para RC quanto para RM em relação às RPs multilameladas e espiculadas. / Objective - To evaluate the diagnostic performance of magnetic resonance imaging (MR) assessing the presence of periosteal reaction (PR) in primary long bone sarcomas using conventional radiography (CR) as the reference standard. Materials and methods After institutional board approval, we retrospectively reviewed the MRI and conventional radiographies of 42 consecutive patients (mean age 22 years, 20 men, 22 women). We included only cases of osteosarcoma or Ewings sarcoma in the long bones with histopathological confirmation. Three experienced musculoskeletal radiologists retrospectively evaluated the presence or absence of periosteal reaction and each pattern of aggressive periosteal reaction in radiographs and MR imaging: Codman triangle, multi layered and spiculated. Radiologists classification was blinded and independent. The readings of the MR images and CR performed by the same observer had an interval of at least three months between them. We use the readings of three observers to assess the interobserver reliability through the Kappa coefficient. Finally a consensus analysis of readings performed by the three observers for both CR and MR was used to calculate the diagnostic performance of MR in detecting PR and classification of each PR aggressive pattern. The radiologist with greater experience made the consensus score of the presence or absence of each periosteal reaction subtype where there was disagreement among observers. 10 Results The interobserver agreement for the detection of PR was almost perfect for the CR and substantial to almost perfect for the MR. The interobserver agreement for the classification of different patterns of PR was moderate to substantial for the presence of Codman triangle. The evaluation of PR multilammelated standards and spiculated was less consensus among radiologists as well for CR as to MR. The diagnostic and the classification of each aggressive PR with MR imaging and with CR were statistically associated with the diagnosis by CR (p <0.05). MR showed high specificity and high negative predictive value, but moderate sensitivity in detecting periosteal reactions when compared to the CR. Conclusions Our results suggest that detection of PR through MR and CR has high reproducibility. MRI showed high specificity and moderate sensitivity for the identification of PR compared to CR. However, the reproducibility of the classification into different patterns of aggressive PRs was relatively low for both CR and for MR regarding the multilamellated and spiculated PRs.
5

Avaliação de sistemas de captação de imagem com fonte de raios X em peças de ferro fundido

Ruy de Macedo Minari 17 December 2009 (has links)
Atualmente, no Brasil e exterior, as avaliações de peças industriais nos sistemas radiográficos são feitas durante ou após a fabricação de maneira a verificar a integridade interna das mesmas. Esses ensaios são de suma importância para atender os requisitos de normas, de projetos e de utilização, garantindo a qualidade e confiabilidade, reduzindo os riscos de quebra de equipamentos e para vidas humanas. Os ensaios radiográficos e fluoroscópicos industriais são métodos de ensaios não destrutivos que se baseiam na absorção diferenciada da radiação penetrante pela peça que está sendo ensaiada. Essa variação na quantidade de radiação absorvida é detectada através de um meio que irá nos indicar, entre outras coisas, a existência de uma descontinuidade interna. Este trabalho tem por objetivo fornecer uma base de dados concreta, baseada em experimentos práticos e reais, que gere conhecimento de suporte ao responsável pela instalação radioativa neste momento decisório através da comparação das diversas técnicas no ensaio de peças de ferro fundido nodular. Os ensaios de campo foram executados com equipamentos de raios X de energia máxima de 320 kV com potencial constante, em 15 peças de ferro fundido nodular, utilizando 05 técnicas de captação de imagem, que são: radiografia convencional, radiografia computadorizada, radiografia digital, fluoroscopia analógica e fluoroscopia digital. As radiografias resultantes dos diversos tipos de captação de imagem foram laudadas por inspetores qualificados pela norma de qualificação de pessoal na área aeronáutica (NAS 410, 2008), e os resultados dos ensaios, para verificar a melhor aderência de cada sistema de imagem com a Norma Nuclear CNEN-NE-3.01, onde qualquer atividade envolvendo radiação deve ser justificada em relação a outras alternativas e produzir um benefício líquido positivo. O nível da aceitabilidade das descontinuidades para que o inspetor possa laudar as radiografias é um acordo entre cliente e fornecedor e, neste caso, foi determinado o nível de qualidade de imagem de 2:4T um nível adequado de qualidade, 2:2T um nível bom e 2:1T um nível ótimo de qualidade de imagem. / Now a days, in Brazil and exterior, the evaluations of industrial parts through X-rays systems are made during or after producing verifying the internal integrity of them. Those testing are sum important for the norms requirements, of projects and utilization, guaranteeing the quality and reliability, reducing the equipment break risks and for human lives. The radiográficos and fluoroscópicos industrial testing are methods of non destructive testing that is based on the differentiated absorption of penetrating radiation by the part that is being tested. That variation in the radiation quantity absorbed is detected through an indicate environment, between other things, the existence of an internal descontinuidade. This paper has for objective supply a base of concrete facts, based in real and practical experiments, that manages knowledge of support to the responsible for the radioactive installation in this decisive moment through the comparison of diverse techniques tested in nodular cast iron parts. The field practice were performed with equipment of X-rays 320 kV maximum energy with constant potential, in 15 pieces nodular cast iron, utilizing 05 image collection techniques, that are: conventional x-ray, x-ray computerized, digital x-ray, fluoroscopia analog and fluoroscopia digital. The resultant x-rays of the diverse image collection kinds were attested by inspectors qualified by t personals qualification norm in the aeronautic area (IN THE 410, 2008), and the results of the testing, verify the better adhesion of each system of image to the Nuclear Norm CNEN-NE-3.01, where any activity involving radiation should be justified regarding other alternatives and produce a positive liquid benefit. The level of the acceptability of the descontinuidades for that the inspector be able to laudar the x-rays is an agreement between client and supplying and, in that case, was determined the image quality level of 2:4T, an adequate level of quality is 2:2T and great level of quality of 2:1T.

Page generated in 0.1173 seconds