• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1943
  • 43
  • 24
  • 21
  • 21
  • 21
  • 11
  • 10
  • 9
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 2025
  • 1645
  • 856
  • 732
  • 368
  • 365
  • 257
  • 214
  • 209
  • 207
  • 177
  • 171
  • 170
  • 169
  • 168
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Incorporação de elipticinas em membranas-modelo : estudo por difração de raios-X

Zacharias, Carlos Renato 23 July 1991 (has links)
Orientador: Iris Concepcion Linares de Torriani / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:36:17Z (GMT). No. of bitstreams: 1 Zacharias_CarlosRenato_M.pdf: 1469619 bytes, checksum: e9cc5cddd872cec2596db426ff3bd55e (MD5) Previous issue date: 1991 / Resumo: A incorporação de Elipticina, uma droga anticancerígena, em membranas-modelo é estudada por técnicas de difração de raios-X à baixo ângulo. Através de diagramas de difração estudamos as alterações estruturais dos fosfolipideos, induzidas pela Elipticina, assim como o processo de cristalização da droga nas bicamadas. Usando diferentes sistemas de membranas-modelo (DPPC, CL, EPC). com várias concentrações Lipídeo:Droga, mostramos que a permeabilidade e a carga liquida dos fosfolipídeos, bem como o pH da fase aquosa contribuem no mecanismo de incorporação da droga. A presença de ELPT incorporada na região hidrofóbica induz variações na espessura da bicamada. A cristalização da droga é dependente da concentração e pH, sendo observada apenas na fase aquosa / Abstract: The incorporation of Ellipticine, an anticancer drug, in lipid model membranes is studied by low angle X-ray diffraction technique. Using diffraction patterns we have studied the structural changes of the lipid bilayers induced by Ellipticine, as well as the crystallization mechanism of the compound in the multilayer system. Using different model membrane systems (DPPC, CL, EPC). with different Lipids: Drug concentrations, we show that the permeability and net charge of the phospholipids. As well as the pH of the aqueous phase, contributed to drug incorporation. The Ellipticine located in the hydrophobic region of the bilayer induces changes in its thickness. The formation of Ellipticine crystals is observed only in the aqueous phase and is pH- and concentration-dependent / Mestrado / Física / Mestre em Física
52

Métodos de análise de fases cristalinas por difracao de raios X

Zeballos Velasquez, Elvira Leticia 22 March 1991 (has links)
Orientador: Iris Concepcion Linares de Torriani / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-09-27T18:38:02Z (GMT). No. of bitstreams: 1 ZeballosVelasquez_ElviraLeticia_M.pdf: 1483512 bytes, checksum: 1ff6f5144edc9afe85b9e34fcad6716a (MD5) Previous issue date: 1990 / Resumo: Neste trabalho vários métodos analíticos destinados à identificação de fases e a determinação de suas concentrações em misturas de multicomponentes são estudados em detalhe e aplicados na análise de amostras provenientes da síntese do material supercondutor Y-Ba-Cu-O para varias relações catiônicas. Para a identificação das fases são aplicados métodos computacionais de simulação de difratogramas. A comparação dos difratogramas calculados com os experimentais permite a determinação das fases presentes. As concentrações das fases identificadas são calculadas pelo Método de Padrão Externo usando as Intensidades de Referência. Estas intensidades são calculadas teoricamente. Na nossa aplicação, a análise qualitativa reportou a presença da fase supercondutora ba2Cu3O7-d , das fases semicondutores Y2BaCuO5 e BaCuO2, e do CuO, com uma presença dominante da primeira fase em todas as nossas amostras. Na maioria das amostras esteve presente o Y2BaCuO5 e o CuO em percentagens variáveis. Somente em uma amostra foi detectada a fase de BaCuO2. Os nossos resultados permitem confirmar a utilidade de métodos computacionais para identificar fases (ou componentes) de misturas complexas, cujo estudo seria extremamente complicado usando métodos tradicionais. A conveniência do método quantitativo aplicado neste trabalho para o cálculo das concentrações também é evidente, estabelecendo-se uma metodologia conveniente para este tipo de análise de fases / Abstract: In this work several analytical methods have been studied and applied to the identification of phases and determination of individual concentrations in multicomponent mixtures obtained from the synthesis of the superconductor material Yba2Cu3O7-d for several cationic ratios. Single phase components were identified by computer simulation of the experimental diffractograms. Concentrations were then calculated by the External Standard Method using the reference intensities calculated for each of the components. The results of the qualitative methods applied to our samples confirmed the presence of the superconducting phase Yba2Cu3O7-d, the semiconducting phases Y2BaCuO5 and BaCuO2, and CuO. In most of the samples Y2BaCuO5 and CuO were present in variable quantities. Only one of the samples contained the BaCuO2 phase. Our results confirmed the practical applicability of the computer simulation methods for the identification of single phase components in complex mixtures which would be hard to analyze by traditional methods. Furthermore, the quantitative method used in this work proved to be quite convenient when combined with the computer simulation of the diffractograms thus establishing a very practical methodology for this type of phase analysis / Mestrado / Física / Mestre em Física
53

Espalhamento de raios X a baixo angulo : estudo de hemoglobinas extracelulares em solução

Souza, Christina Franco de 22 July 1990 (has links)
Orientador: Iris Concepcion Linares de Torriani / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:33:13Z (GMT). No. of bitstreams: 1 Souza_ChristinaFrancode_D.pdf: 4793967 bytes, checksum: 74b68cad0c27d2b7d2b2fb027fe59ab2 (MD5) Previous issue date: 1990 / Resumo: A técnica de espalhamento de raios X a baixo ângulo tem sido bastante utilizada nos últimos anos no estudo de proteínas em solução. Curvas de espalhamento de alta resolução, além de fornecerem parâmetros dimensionais, possibilitam a obtenção de informações sobre a estrutura quaternária de macromoléculas através de simulações com modelos. Neste trabalho, estudamos a eritrocruorina do anelídeo Glossoscolex paulistus (massa molecular de 3.23x106). Curvas de espalhamento a baixo ângulo de várias concentrações da proteína em solução foram obtidas com um gerador convencional de raios X. A partir destes dados foi possível determinar os valores de raio de giro e dimensão máxima na molécula por gráficos de Guinier e transformada indireta de Fourier. Obtivemos, também, curvas de alta resolução no síncrotron do LURE, Orsay, França. As intensidades espalhadas. por apresentarem uma série de máximos nos ângulos maiores, pareceram apropriadas ao cálculo de modelos. Para tal usamos um programa de computador desenvolvido por O. Glatter [7]. O modelo inicial, composto de 186 esferas idênticas, foi estruturado com base em informações disponíveis de microscopia eletrônica. Modificações sistemáticas deste modelo levaram a uma estrutura final que consiste de 12 subunidades principais arranjadas em duas camadas hexagonais sobrepostas formando um cilindro com uma subunidade adicional no centro. Durante o processo de ajuste do modelo, diferentes pesos foram atribuídos às esferas que compunham as subunidades principais. 0 modelo final simula bem as curvas experimentais e contém informação sobre as regiões de maior densidade eletrônica na molécula, sugerindo uma possível localização dos grupos heme / Abstract: Small angle X-ray scattering is a technique that has been widely used during the last decade for the study of proteins in solution. High resolution scattering curves, can not only provide information on the dimensional parameters of the molecules, but also lead to a description of the quaternary structure of the protein by filling the experimental intensity curves and distance distribution functions with those calculated for a model molecule. This work reports studies of erythrocruorin from the annelid species Glossoscolex paulistus (molecular weight 3,23 x 106). Small angle scattering curves from various concentrations of this protein in solution were obtained with a conventional X-ray generator. The radius of gyration and maximum dimension of the molecule were obtained from Guinier plots and inverse Fourier transform. High resolution intensity curves were obtained al the synchrotron source at LURE, Orsay, France. These curves presented a number of maxima at higher angles and seemed adequate for model calculations. These were performed using the computer program developed by O. Glatter [7]. The initial model, formed by 186 identical spheres, was built using the information available from electron microscopy. Systematic modifications of this model lead us to a final structure consisting of 12 principal subunits, arranged in two superposed hexagonal layers forming a hexagonal cylinder, with an additional subunit in its center. During the filling procedure, different weights were assigned to the spheres composing the structure. The final model reproduces the experimental scattering curves and contains information on the more electron-dense regions in the molecule, thus suggesting the possible site of the heme groups / Doutorado / Física / Doutor em Ciências
54

Algumas aplicações da fluorescência de raios x por excitação radioisotópica em rochas e minérios / Not available.

Claudio Lisias Seignemartin 10 January 1975 (has links)
São apresentados, em primeiro lugar, alguns dos principais conceitos em que se fundamenta a técnica da fluorescência de raios X por excitação radioisotópica. Seguem-se algumas considerações sobre a parte instrumental, analisando fontes, câmaras de excitação e detetores e, principalmente a conjugação destes fatores, aqui denominada simplesmente geometria. Nos itens seguintes são analisados os fatores responsáveis pela introdução de ergos nas dosagens, e os processos analíticos, onde é enfatizado o método da dupla diluição com padrões, utilizado na parte experimental deste trabalho. São apreciadas algumas das possíveis aplicações da metodologia proposta, principalmente no campo da pesquisa mineral, e, a seguir a técnica apresentada é comparada a outros métodos analíticos, incluindo a própria fluorescência de raios X convencional. Três exemplos de dosagens efetivamente realizadas demonstram a praticidade e aplicabilidade do método. / Not available.
55

Algumas aplicações da fluorescência de raios x por excitação radioisotópica em rochas e minérios / Not available.

Seignemartin, Claudio Lisias 10 January 1975 (has links)
São apresentados, em primeiro lugar, alguns dos principais conceitos em que se fundamenta a técnica da fluorescência de raios X por excitação radioisotópica. Seguem-se algumas considerações sobre a parte instrumental, analisando fontes, câmaras de excitação e detetores e, principalmente a conjugação destes fatores, aqui denominada simplesmente geometria. Nos itens seguintes são analisados os fatores responsáveis pela introdução de ergos nas dosagens, e os processos analíticos, onde é enfatizado o método da dupla diluição com padrões, utilizado na parte experimental deste trabalho. São apreciadas algumas das possíveis aplicações da metodologia proposta, principalmente no campo da pesquisa mineral, e, a seguir a técnica apresentada é comparada a outros métodos analíticos, incluindo a própria fluorescência de raios X convencional. Três exemplos de dosagens efetivamente realizadas demonstram a praticidade e aplicabilidade do método. / Not available.
56

Levantamento das condições de biossegurança em radioproteção nos consultórios odontológicos de Campo Grande/MS / Survey on X-ray biosecurity protection condictions at dentistry offices in Campo Grande/MS

Pereira, Nara Rejane Santos January 2008 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by wesley oliveira leite (leite.wesley@yahoo.com.br) on 2009-09-15T20:16:21Z No. of bitstreams: 1 2008_NaraRejaneSantosPereira.pdf: 437366 bytes, checksum: cf38da86572d7f5f5a6790015ac52065 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2010-01-29T13:20:07Z (GMT) No. of bitstreams: 1 2008_NaraRejaneSantosPereira.pdf: 437366 bytes, checksum: cf38da86572d7f5f5a6790015ac52065 (MD5) / Made available in DSpace on 2010-01-29T13:20:07Z (GMT). No. of bitstreams: 1 2008_NaraRejaneSantosPereira.pdf: 437366 bytes, checksum: cf38da86572d7f5f5a6790015ac52065 (MD5) Previous issue date: 2008 / O uso dos raios X em Odontologia resulta em um diagnóstico apurado, e muitas vezes, definitivo de estruturas bucais nos tratamentos odontológicos, em função disto diminuir os riscos da infecção cruzada durante exames radiográficos merece tanta consideração quanto controlar os riscos do uso da radiação ionizante e de dar destino adequado aos resíduos produzidos. Objetivou-se neste estudo examinar as condições e as condutas dos cirurgiões-dentistas de Campo Grande (MS) com relação à biossegurança, a radioproteção e aos resíduos dos procedimentos radiográficos. Procedeu-se a seleção aleatória de 120 profissionais entre os 600 questionários enviados aos profissionais com consultórios registrados na Vigilância Sanitária Municipal, entre os que responderam a um questionário contendo questões abertas, fechadas e respostas textuais com múltiplas alternativas, após assinarem o Termo de Consentimento Livre e Esclarecido. Os resultados obtidos demonstraram que os entrevistados conhecem satisfatoriamente biossegurança do exame radiográfico e o processamento radiográfico; mais da metade dos profissionais entrevistados não sabe indicar as técnicas radiográficas; são pouco informados sobre gerenciamento de resíduos, mas apresentam bom conhecimento sobre radioproteção. Com base nestes dados, foi elaborado um protocolo de biossegurança em radioproteção obedecendo às normas preconizadas para o controle de infecção cruzada e proteção radiológica, onde estão descritos os passos para o preparo do ambiente de trabalho, do paciente e da equipe profissional, pois, garantir a qualidade das imagens radiográficas com o mínimo de exposição para o paciente e equipe é um desafio e uma obrigação para o cirurgião-dentista. _________________________________________________________________________________________ ABSTRACT / The use of X-ray in Dentistry results in a refined diagnosis, and many times, definitive of buccal structures in dental treatments, due to minimize the risks of the crossed infection during X-ray examinations it deserves as much consideration how the control of risks of the ionizing radiation use and to give appropriate destination to the produced residues. The aim of this study was to examine the conditions and the behaviors of Campo Grande (MS) dentists with regards to the biosecurity, X-ray protection and to the residues of X-ray procedures. A random election of 120 professionals of 600 questionnaires sent to the professionals with dentistry's offices registered in the Mayor Monitoring Sanitary; among who had answered to a questionnaire contend opened questions, closed and literal answers with multiple choices, after signing the Term of Free and Clarified Assent. Obtained results showed that the interviewed dentists satifactory know biosecurity on X-ray examination and processing; more than the half of the interviewed professionals does not know how to indicate X-ray techniques; they are poorly informed on management of residues, but they present good knowledge on X-ray protection. Based on these data, a X-ray biosecurity protocol was elaborated obeying the norms praised for the control of crossed infection and X-ray protection, where the steps for the preparation of the work environment, of the patient and the professional team are described, therefore, to guarantee the quality of the X-ray images with the minimum of exposition for the patient and its team is a challenge and an obligation for the dentist.
57

Análise por difração de raios-x da interface plasma-superfície durante a nitretação a plasma

Clarke, Thomas Gabriel Rosauro January 2004 (has links)
O presente trabalho apresenta o desenvolvimento de um equipamento utilizado para acompanhamento e monitoramento do processo de nitretação a plasma enquanto ele ocorre, ou seja, de forma in-situ. Os resultados obtidos com a utilização deste equipamento são demonstrados e confirmam a potencialidade da técnica na caracterização de mecanismos de nitretação a plasma. Ensaios de adaptação à técnica foram realizados, visando adquirir experiência no reconhecimento e detecção de fases formadas durante o processo e de possibilidades de caracterização proporcionadas pela técnica. Desta forma a influência de três composições gasosas na formação de camadas nitretadas em aço médio carbono AISI 1045 foi avaliada de forma in-situ por difração de raios-X e post-mortem por metalografia, GDOS e microdureza Vickers. A composição gasosa de 76% N2 – 24% H2 mostrou alto poder de nitretação, e formou camadas de compostos espessas e zonas de difusão profundas, com aumentos consideráveis de dureza. A composição gasosa de 5% N2 – 95% H2, formou camadas de compostos pequenas e zonas de difusão profundas, além de aumentos de dureza superficial. Em uma segunda avaliação, amostras de aço AISI 1045, foram nitretadas em duas composições gasosas: 5% N2 – 95% H2 e 25% N2 – 75% H2, nas temperaturas de 450ºC, 480ºC, 520ºC, 540ºC e 560ºC. Com o acompanhamento in-situ por difração de raios-X de trechos específicos de 2Θ correspondentes às linhas de difração das fases γ’ e ε, foi possível obter o tempo de incubação da fase γ’ para cada combinação composição gasosa - temperatura, que foram comparados com dados já existentes para nitretação a gás. Também foi possível o acompanhamento do crescimento, desenvolvimento e de mudanças na largura das linhas destas fases O tempo de incubação da fase γ’ permitiu a comparação entre os resultados das nitretações a plasma e os resultados previstos por um diagrama de Lehrer, e uma boa correlação entre as fases previstas pelo diagrama e as encontradas na prática foi encontrada. As amostras foram avaliadas ainda por difração de raios-X em ângulos rasantes, que permitiu a caracterização das camadas mais superficiais das amostras e, com base nestes resultados e nos resultados das análises in-situ, obteve-se um mapa prático de previsão de fases para a nitretação a plasma.
58

Caracterização tecnológica das argilas aluvionares da Região Metropolitana de Fortaleza / Technological characterization of alluviums clays the metropolitan region of Fortaleza

Moreira, Marcos Aurélio Marcelino January 2015 (has links)
MOREIRA, Marcos Aurélio Marcelino. Caracterização tecnológica das argilas aluvionares da Região Metropolitana de Fortaleza. 2015. 104 f. Dissertação (Mestrado em Geologia)-Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Jairo Viana (jairo@ufc.br) on 2017-05-23T22:02:58Z No. of bitstreams: 1 2015_dis_mammoreira.pdf: 12962540 bytes, checksum: 0276faa11d6d883d7b6b262d67284699 (MD5) / Approved for entry into archive by Jairo Viana (jairo@ufc.br) on 2017-05-23T22:03:09Z (GMT) No. of bitstreams: 1 2015_dis_mammoreira.pdf: 12962540 bytes, checksum: 0276faa11d6d883d7b6b262d67284699 (MD5) / Made available in DSpace on 2017-05-23T22:03:09Z (GMT). No. of bitstreams: 1 2015_dis_mammoreira.pdf: 12962540 bytes, checksum: 0276faa11d6d883d7b6b262d67284699 (MD5) Previous issue date: 2015 / In the metropolitan area of Fortaleza various ceramic industries, whose main product is the manufacture of bricks, has been facing major problems due to the need to reuse the ceramic body, or even the loss of it after firing, for not meeting the specifications of the market. This occurs mostly due to the mixing ratio of the raw material introduced into the process is inadequate, due to the lack of knowledge of its characteristics, resulting in additional electricity consumption, under-utilization of equipment and skilled labor and hence increase in production costs. The technological characterization of clays used in some ceramics of the region can provide input for improvement of the process used in these industries. The methodology used in this work involved the selection of extraction areas for technological characterization of the clay and setting a ratio of adequate mixing for the manufacture of bricks, based on the raw material used by each selected ceramic industry, and to evaluate the quality of material for the manufacture of clay tiles. Parallel analyzes were performed X-ray diffraction and fluorescence and scanning electron microscopy, where we observed a predominance of kaolinite and ilíticas clays in alluvial clays of the region, being also observed interstratified kaolinite and smectite associations. Such analysis was also applied in order to identify properties that could interfere with the ceramic process. Based on the results of technological characterization was identified that only one sample may be used directly in the manufacture of tiles or bricks, without the need for mixing. Among the remaining samples, the proportions set to mixtures of clays seem to be satisfactory for the manufacture of products for red ceramics. / Na Região Metropolitana de Fortaleza várias indústrias cerâmicas, cujo principal produto é a fabricação de tijolos, tem enfrentado grandes problemas devido à necessidade de reaproveitamento da massa cerâmica, ou mesmo a perda da mesma após a queima, por não atender as especificações do mercado. Isso decorre na maioria das vezes devido à proporção de mistura da matéria-prima introduzida no processo ser inadequada, decorrente da falta de conhecimento de suas características, acarretando no consumo adicional de energia elétrica, subutilização dos equipamentos e mão-de-obra e, consequentemente, aumento dos custos de produção. A caracterização tecnológica das argilas utilizadas em algumas cerâmicas da região pode fornecer subsídios para melhoria do processo utilizado nessas indústrias. A metodologia utilizada nesse trabalho envolveu a seleção de áreas de extração para caracterização tecnológica da argila e definição de uma proporção de mistura adequada para fabricação de tijolos, com base na matéria-prima utilizada por cada indústria cerâmica selecionada, além de avaliar a qualidade do material argiloso para fabricação de telhas. Paralelamente foram realizadas análises de difração/fluorescência de raios X e microscopia eletrônica de varredura, onde foi possível verificar uma predominância de argilas cauliníticas e ilíticas nas argilas aluvionares da região, sendo também observadas associações intestratificadas de caulinita e esmectita. Tais análises também foram aplicadas com o propósito de identificar propriedades que pudessem interferir no processo cerâmico. Com base nos resultados de caracterização tecnológica foi identificado que somente uma amostra pode ser utilizada diretamente na fabricação de telhas ou tijolos, sem a necessidade de mistura. Com relação às demais amostras, as proporções definidas para misturas de argilas se mostraram satisfatórias para fabricação de produtos voltados para cerâmica vermelha.
59

Análise da equação de Scherrer pela teoria dinâmica da difração de Raios X aplicada a distribuições de tamanho de cristalitos

Muniz, Francisco Tiago Leitâo January 2017 (has links)
MUNIZ, F. T. L. Análise da Equação de Scherrer pela Teoria Dinâmica da difração de raios X aplicada a distribuições de tamanho de cristalitos.2017. 100 f. Tese (Doutorado em Física) - Centro de Ciências, Universidade Federal do Ceará, 2017. / Submitted by Pós-Graduação em Física (posgrad@fisica.ufc.br) on 2017-06-05T19:11:22Z No. of bitstreams: 1 2017_Tese_ftlmuniz.pdf: 16101227 bytes, checksum: a17650253be340430065485513198f24 (MD5) / Approved for entry into archive by Giordana Silva (giordana.nascimento@gmail.com) on 2017-06-07T09:41:59Z (GMT) No. of bitstreams: 1 2017_Tese_ftlmuniz.pdf: 16101227 bytes, checksum: a17650253be340430065485513198f24 (MD5) / Made available in DSpace on 2017-06-07T09:41:59Z (GMT). No. of bitstreams: 1 2017_Tese_ftlmuniz.pdf: 16101227 bytes, checksum: a17650253be340430065485513198f24 (MD5) Previous issue date: 2017 / CNPq / The Scherrer equation is a widely used tool to determine the crystallite size of polycrystalline samples. However, it is not clear if one can apply it to large crystallite sizes because its derivation is based on the kinematical theory of X-ray diffraction. For large and perfect crystals, it is more appropriate to use the dynamical theory of X- ray diffraction. Due to appearance of polycrystalline materials with a high degree of crystalline perfection and large sizes, it is the authors' belief that it is important to establish the crystallite size limit for which the Scherrer equation can be applied. In this work, the diffraction peak profiles are calculated using the dynamical theory of X-ray diffraction for several Bragg reflections and crystallite sizes for Si, LaB6 and CeO2. The full width at half-maximum is then extracted and the crystallite size is computed using the Scherrer equation. It is shown that for crystals with linear absorption coeficients below 2117.3 cm -1 the Scherrer equation is valid for crystallites with sizes up to 600 nm. It is also shown that as the size increases only the peaks at higher 2θ angles give good results, and if one uses peaks with 2θ > 60° the limit for use of the Scherrer equation would go up to 1 μm. Next, a study was carried out taking into account crystallite size distributions. The diffraction profiles were calculated by dynamic theory considering narrow and wide distributions (Gaussian and Lognormal) of crystallite size to crystals of LaB6. It was shown that the larger the value of the standard deviation, ie, the wider the distribution function, the greater the error in the crystallite size value obtained by the Scherrer equation in these profiles. It has also been shown that for any of the centered distributions in any region of size and for any standard deviation value used in this work, the integrated width (FWHM int ) of the diffraction peaks provides better results for the crystallite size in comparison to the peak width (FWHM). / A equação de Scherrer é uma ferramenta amplamente utilizada para determinar o tamanho de cristalito em amostras policristalinas. No entanto, não é inteiramente clara confiabilidade de sua aplicação para cristalitos de tamanhos grandes porque a sua dedução é baseada na teoria cinemática de difração de raios X. Para cristais grandes e perfeitos, é mais adequado utilizar a teoria dinâmica de difração de raios X. Por causa do aparecimento de materiais policristalinos com um alto grau de perfeição cristalina e de tamanhos grandes acreditamos que seja importante estabelecer um limite de tamanho de cristalito para os quais a equação de Scherrer pode ser aplicada. Neste trabalho, os perfis de difração dos picos são calculados utilizando a teoria dinâmica da difração de raios X para várias reflexões de Bragg e tamanhos de cristalitos de Si, LaB6 e CeO2. A largura a meia altura dos picos (FWHM) é então extraída e o tamanho de cristalito é calculado utilizando a equação de Scherrer. Mostrou-se que para cristais com coeficientes de absorção linear abaixo de 2117,3 cm -1 a equação de Scherrer é válida para cristalitos com tamanhos até 600 nm. Mostra-se também que à medida que o tamanho aumenta apenas os picos com valores de 2_ mais elevados fornecem bons resultados, e se formos utilizar picos com 2θ > 60° o limite para o uso da equação de Scherrer ir até 1 μm. Em seguida foi feito um estudo levando em consideração distribuições de tamanho de cristalito (gaussiana e lognormal) para cristais de LaB6. Foram calculados os perfis de difração pela teoria dinâmica considerando distribuições de tamanho de cristalito estreitas e largas. Foi mostrado que quanto maior o valor do desvio padrão, ou seja, mais alargada for a função distribuição, maior também será o erro no valor do tamanho de cristalito obtido pela equação de Scherrer nestes perfis. Também foi mostrado que, para quaisquer das distribuições centralizadas em qualquer região de tamanho e para qualquer valor de desvio padrão utilizados, a largura integrada (FWHMint) dos picos de difração fornece melhores resultados para o tamanho de cristalito do que a largura do pico (FWHM).
60

Comparação entre a avaliação radiográfica e a tomográfica do ângulo articular metatarsal distal

Cruz, Eduardo Pedrini January 2015 (has links)
INTRODUÇÃO: O hallux valgus é a deformidade mais comum do pé do adulto e é frequentemente incapacitante requerendo tratamento cirúrgico. O ângulo articular metatarsal distal (AAMD) é uma das variáveis importantes no estudo da deformidade, mas possui baixa correlação interobservadores quando avaliado pela radiografia. O objetivo deste estudo foi avaliar um método tomográfico de aferir este ângulo comparando-o com a medida radiográfica existente. MATERIAL E MÉTODOS: O AAMD de 77 pés (43 pacientes) foi avaliado através de tomografia computadorizada por dois observadores. Os valores encontrados foram comparados entre os observadores e entre a medição radiográfica utilizando o coeficiente de correlação e concordância (CCC) proposto por King e análise de Bland-Altmann para concordância entre os métodos. RESULTADOS: Foi encontrado índice de concordância alto na medição tomográfica entre os observadores com CCC = 0,90 e p < 0,001. Em relação a mensuração radiográfica com a tomográfica houve uma concordância com CCC = 0,667 de com p < 0,001. Na análise gráfica de Bland-Altman a presença de round sign positivo sugere um aumento da diferença da medição radiográfica com a tomográfica e está associado a valor alto do AAMD. CONCLUSÃO: A mensuração do AAMD pelo método tomográfico demonstrou maior correlação interobservadores do que o método radiográfico. Em casos em que há dúvida sobre alteração patológica da inclinação da cabeça metatarsal com ângulos articulares metatarsais distais (AAMD) elevados e, principalmente, com a presença de round sign positivo, a tomografia pode ser um método alternativo para planejamento cirúrgico pré-operatório.

Page generated in 0.1051 seconds