Spelling suggestions: "subject:"residual""
181 |
Utilização de águas receptoras de efluentes urbanos em sistemas de irrigação localizada superficial e subsuperficial na cultura da alface americana (Lactuca sativa L.)Biscaro, Guilherme Augusto [UNESP] 06 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-06Bitstream added on 2014-06-13T20:43:42Z : No. of bitstreams: 1
biscaro_ga_dr_botfca.pdf: 709283 bytes, checksum: bb063114527e6c67e93b18508e3b3028 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve como finalidade avaliar a viabilidade do uso da água do Ribeirão Lavapés, que recebe os esgotos doméstico e industrial não tratados da cidade de Botucatu, São Paulo, para utilização em sistemas de irrigação localizada por gotejamento dispostos superficialmente e subsuperficialmente. Avaliou-se os coeficientes de uniformidade e eficiência da mangueira gotejadora, o uso ou não do tanque reservatório e a aplicação de cloro na água. Realizou-se a caracterização química do solo antes da aplicação das águas residuárias e as alterações de suas características no decorrer de quatro ciclos de cultivo de alface; analisou-se também a presença de coliformes fecais, Salmonella spp e formas evolutivas de parasitas humanos (cistos de protozoários e ovos de helmintos) nas amostras de planta, na água de irrigação e no solo. Concluiu-se que os tratamentos propostos não apresentaram diferenças estatisticamente significativas, sendo a melhor combinação a disposição superficial das mangueiras gotejadoras, a aplicação de cloro e a utilização da água diretamente do Ribeirão Lavapés, sem necessidade do tanque reservatório. / This study was carried out to evaluate the viability of using the Ribeirão Lavapés's water, which receives the domestic and industrial not treated sewers of the city of Botucatu, São Paulo, for application in drip irrigation systems, disposed superficially and sub-superficially. It was evaluated the uniformity coefficients, the efficiency of the drip tape, the possible use of the reservatory tank, and also the application of chlorine in the water. Chemical characterization of soil before the application of the waste waters, and changes of its characteristics during the four cycles of lettuce cultivation, were analyzed; it was also observed the presence of fecal coliformes, Salmonella spp., and evolutionary forms of human parasites (protozoa cysts and helmint eggs) in plant samples, in irrigation water, and in the soil. Treatments did not present any significant differences, where the best combination was the superficial arrangement of the drip tapes, the application of chlorine, and the utilization of water directly from the Ribeirão Lavapés, being not necessary the use of the reservatory tank.
|
182 |
Sistema de tratamento de águas residuárias de suinocultura em reator anaeróbio compartimentado seguido de filtro aeróbio e reator anóxicoBraz, Guilherme Henrique Rodrigues [UNESP] 16 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:47Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-12-16Bitstream added on 2014-06-13T19:11:31Z : No. of bitstreams: 1
000749710.pdf: 2411858 bytes, checksum: 2af5b0f6a4954628035e6d23916bfc05 (MD5) / A digestão anaeróbia é uma alternativa de baixo custo para o tratamento de águas residuárias de suinocultura, com possibilidade de produção de energia. Neste trabalho foi utilizado um sistema de tratamento, em escala piloto, composto por reator um anaeróbio compartimentado (ABR) com duas câmaras, um filtro aerado submerso (FAS) e um reator de fluxo ascendente com manta de lodo (USB) anóxico para o tratamento de águas residuárias de suinocultura. Na primeira câmara do ABR foram aplicados tempos de detenção hidráulicos (TDH) de 40,6 a 10,6 h e carga orgânicas volumétricas (COV) de 4,8 a 37 g DQO (L d)-1. Os maiores valores para produção volumétrica de metano e a produção específica de metano no ABR foram de 0,843 L CH4 (L d)-1 e 0,254 L CH4 (g DQOtotal removida)-1 e a concentração de metano no biogás variou de 75 a 83%. No FAS e no USB anóxico foram utilizados TDH que variaram de 12,7 a 3,3 horas e de 10,8 a 2,8 horas, e COV variando de 5 a 18,7 g DQO (L d)-1 e 3,4 a 28,1 g DQO (L d)-1, respectivamente. No FAS foram utilizados 3 diferentes ciclos de aeração intermitente e foi utilizado anéis de plástico de conduíte como meio suporte. A produção de nitrito no FAS chegou a 171 mg L-1 durante o ensaio 4 e no biogás do USB obteve-se 37% de N2. A concentração de coliformes totais e termotolerantes no afluente alcançou valores 1,1x1012 e 2,4x1011 NMP(100 ml)-1, respectivamente Com a inclusão do pós-tratamento foi possível obter eficiências de remoção de DQOtotal, sólidos suspensos totais (SST), P-total, e coliformes totais e termotolerantes de até 85, 88, 77 e 5,07 log NMP (100 ml) -1, respectivamente para o sistema de tratamento. As maiores remoções de micronutrientes foi de 85% para Cu, 84% para Fe, 78 % para Mn e 90% para Zn / Anaerobic treatment is a low cost alternative for treating swine wastewater, with the possibility of energy producing. In this work we used a treatment system , pilot scale , composed by anaerobic baffled reactor (ABR ) , submerged aerated filter (SAF ) and reactor upflow sludge blanket ( USB ) for the treatment of anoxic swine wastewater. ABR were applied hydraulic retention time (HRT) from 40.6 to 10.6 h and organic loading rate (OLR) from 4.8 to 37 g COD (L d)-1. The highest values for volumetric methane production and specific methane production in ABR were 0.843 L CH4 (L d)-1and 0.254 L CH4 (g total COD removed)-1 and the concentration of methane in the biogas ranged 75-83 %. In FAS and anoxic USB the HRT were used ranging from 12.7 to 3.3 and 10.8 to 2.8 hours, respectively , and OLR ranging from 5 to 18.7 g COD (L d)-1 and 3 4 to 28.1 g COD (L d)-1. FAS were used in three different cycles of intermittent aeration and used plastic rings conduit as packing material. The production nitrite in the FAS reached 171 mg L-1 in test 4 when the biogas produced in anoxic USB obtained 37 % N2. The concentration of thermotolerant and total coliforms in the affluent reached values 1.1 X1012and 2.4 x1011 MPN (100 ml) -1. With the inclusion of post- treatment was possible to obtain total COD removal efficiencies, Total suspended solids (TSS ) , total P , and total and fecal coliforms up to 85,88,77 and 5,07 log MPN (100 ml) -1, respectively. Removal of micronutrients has reached values higher than 85% for Cu, Fe 84 % to 78% to 90% Mn and Zn
|
183 |
Tratamento físico-químico de efluentes de curtume por meio de filtros de membrana seletiva /Geromel, Camila Gabriela Alexandre. January 2012 (has links)
Orientador: Tsunao Matsumoto / Banca: Dib Gebara / Banca: Luís Fernando Rossi Léo / Resumo: Historicamente, as indústrias de curtimento de couro são consideradas extremamente poluidoras devido aos seus rejeitos com altas concentrações de matéria orgânica e metais pesados, características que influenciam em vários parâmetros de análise de efluentes, tais como DBO, DQO e sólidos totais. Vários trabalhos foram desenvolvidos, tendo como objeto de estudo o efluente da empresa Fuga Couros Jales Ltda, sediada no município de Jales/SP. O reator anaeróbio UASB em etapa única foi utilizado primeiramente, como dispositivo de tratamento, e posteriormente foi analisado este mesmo reator combinado a pré-tratamento físico químico e pós-tratamento biológico, no entanto nenhum deles apresentou satisfatória eficiência da remoção de DBO, assim como também não atenderam as exigências da legislação vigente, em praticamente quase todos os parâmetros analisados. O presente trabalho teve como objeto de estudo o efluente deste Curtume e seu objetivo principal foi reduzir a carga de compostos de enxofre por oxidação química e reduzir a carga orgânica e de sólidos nas etapas de coagulação-floculação-sedimentação com posterior separação por membrana microfiltrante, e a redução dos sólidos remanescentes no efluente, na etapa de ultrafiltração por membrana, a concentrações aceitáveis para o descarte de efluentes. Para tanto, foram analisados previamente em jar-test uma faixa de pH adequada de trabalho para adição de cloreto férrico e o policloreto de alumínio, assim como analisar seus comportamentos quanto à eficiência de remoção de sólidos e, com relação ao peróxido de hidrogênio, permanganato de potássio e sulfato manganoso quanto à sua eficiência na oxidação de sulfeto. Posteriormente, foram analisadas as interações entre cada um destes reagentes e, em posse dos resultados destas análises, optou-se por aplicar o sulfato... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Historically, the industries of leather tanning are considered highly polluting due to its tailings with high concentrations of organic matter and heavy metals, characteristics that influence on several effluent parameters, such as BOD, COD and total solids. Several studies have been developed, object of to study, the effluent from the company Fuga Couros Jales Ltda, whose locate in Jales/SP city, Brazil. The UASB reactor in single step was used on time first as a treatment device, and later the same reactor combined physical and chemical pre-treatment and post-biological treatment, however none showed removal efficiencies of DBO satisfactory, and also did not reached the goal of the current legislation practically in all analyzed parameters. This research had as object of its study the tannery effluent and its main goal was to reduce the sulfur compounds concentration by chemical oxidation, organic loading and solids reduction in the stages of coagulation-flocculation-sedimentation with subsequent microfiltration membrane separation, and, the reduction of solids still remaining in the wastewater, in ultrafiltration membrane step to acceptable concentrations for effluent disposal. Therefore, were analyzed previously in Jar-Test a pH range suitable for working with the ferric chloride and polyaluminium chloride, and, analyzing their behavior as regards the solids removal efficiency and, with respect to hydrogen peroxide, potassium permanganate and manganous sulfate as the efficiency in the sulfide oxidation. Subsequently, we analyzed the interactions between each of these reagents, and ownership of the results of these analyzes, we chose to apply the manganous sulfate and ferric chloride to the physical-chemical treatment. The proposed treatment presents a good sulfide and suspended solids removal (62% and 96%.), However... (Complete abstract click electronic access below) / Mestre
|
184 |
Avaliação da qualidade da agua subterranea e microbiologia do solo em area irrigada com efluente de lagoa anaerobiaBurbarelli, Rodrigo Carminatti 05 August 2018 (has links)
Orientadores: Jose Roberto Guimarães, Antonio Roberto Siviero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-05T17:55:09Z (GMT). No. of bitstreams: 1
Burbarelli_RodrigoCarminatti_M.pdf: 837636 bytes, checksum: a680551b3d7d19e7c9c5a552bce15c34 (MD5)
Previous issue date: 2004 / Resumo: Neste projeto avaliou-se a influência da aplicação de efluente de lagoa de estabilização anaeróbia e água no solo, alterações em sua flora microbiana e principalmente alterações na qualidade das águas subterrâneas. Isso se deu por meio de análises de indicadores microbiológicos de poluição e alguns parâmetros físico-químicos, tanto do solo quanto da água subterrânea. O efluente da lagoa de estabilização foi aplicado no solo de duas formas, diretamente e também após receber aplicação de cloro para a remoção de microrganismos. A técnica de aplicação utilizada foi a de sulcos rasos, como forma de pós-tratamento do efluente. Visou-se o reuso agrícola do efluente, ou seja, a utilização da água para irrigação e dos nutrientes presentes nesse efluente, principalmente nitrogênio e fósforo, pela cultura de milho (Zea mays). Além disso, a carga orgânica remanescente no efluente favorece o metabolismo microbiano no solo, onde pode ocorrer a conversão da matéria orgânica complexa em formas químicas mais simples, acessíveis à planta. Este sistema possui a vantagem de reduzir e, em alguns casos eliminar o uso de fertilizantes industrializados. Além de suprir a demanda de água requerida no manejo de culturas agrícolas, protege os corpos d¿água receptores da deterioração causada pelo lançamento deste efluente. Os parâmetros microbiológicos monitorados no solo foram fungos totais e bactérias heterotróficas ou totais e os parâmetros físico-químicos foram pH no início e final do experimento e umidade do solo coletado. Com relação à água subterrânea e efluente da lagoa anaeróbia, os parâmetros microbiológicos monitorados foram coliformes totais, Escherichia coli, Streptococcus faecalis e bactérias heterotróficas durante a primeira safra. Na segunda e terceira safras passou-se a monitorar ovos de helmintos e cistos de protozoários, também os parâmetros físico-químicos pH e condutividade elétrica. Os dados colhidos durante o desenvolvimento do projeto foram comparados com os índices estabelecidos pela legislação vigente e aspectos de saúde. Esse trabalho é parte do edital do projeto temático CT-HIDRO 2001, financiado pelo CNPQ e pelo Fundo Setorial de Recursos Hídricos. Projeto este que envolve várias faces da engenharia sanitária/ambiental. Os resultados desta pesquisa recomendam a desinfecção dos efluentes para uso na forma de irrigação ou reuso / Abstract: The present project the influence of stabilization ponds effluent and water application on soil and changes in its microflora but the main aim was the evaluation of groundwater quality. This research took place by the assessment of microbiological indicators of pollution and a little physicochemical parameters both in soil and groundwater. The effluent application on soil happened directly and after desinfection by chlorine to microbial removal. The technique of application of effluent used was the shallow ruts like a post treatment and reuse of its nutrients like nitrogen and phosphorus in maize crops (Zea mays). Furthermore the organic matter that remains on in the effluent improves the microbial metabolism in soil converting this complex organic matter to simple chemical forms assessable to crops. The main advantage of this system is reduce or eliminate the use of fertilizer and water supply necessity protecting the water bodies of degradation. Soil was controlled by microbiological analyses of total fungi and total bacteria and physicochemical analyses of moisture and pH in the beginning and the end of the experiment. Groundwater quality was assessed by microbiological analises: Escherichia coli, Streptococcus faecalis (Enterococos) and heterophic bacteria in the first harvest. In the second and third harvest was assess by physicochemical analyses: pH and electrical condutctivity. Besides helminth eggs and protozoan cists like a new microbiological analysis. The presents work data was compared to the present legislation and heal aspects. This work is part of a licence of the project CT-HIDRO 2001 financed by CNPq and Fundo Setorial de Recursos Hídricos. This project involves many faces of environmental engeneering. The results reached in this work suggests that the desinfection of efluente is necessary to the use of this water in irrigation and reuse / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
185 |
Coalescencia de imisciveis em filme de agua residuaria / Coalescence of immiscible in wasterwater LonaBufo, Moacir José, 1938- 26 October 2006 (has links)
Orientador: Liliane Maria Ferrareso Lona / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-07T08:12:19Z (GMT). No. of bitstreams: 1
Bufo_MoacirJose_D.pdf: 987875 bytes, checksum: 8fa242d4879a20b9592f76cbbb4e5681 (MD5)
Previous issue date: 2006 / Resumo: Águas residuárias urbanas e industriais, cujo destino final em nível mundial é o rio, sempre apresentam imiscíveis na forma de película e gotas, sejam de óleos comestíveis ou óleos lubrificantes ou solventes petroquímicos. A grande dificuldade em separar estes imiscíveis está no diâmetro de gotas inferior a 40 microns. A melhor tecnologia, hoje, produz água tratada ainda com gotas de 20 microns e com teor de imiscível igual a 10 mg/litro. O autor do presente trabalho, em 1984, acidentalmente criou um coalescedor a filme, e realizou ensaios numa instalação em escala piloto, para encontrar uma solução para um problema de imiscível em água, de uma indústria petroquímica. Os ensaios qualitativos realizados mostraram que a tecnologia é eficiente para separar imiscíveis em água. Os estudos, naquela época, não tiveram continuidade. O regime de operação da instalação piloto era contínuo. A aparelhagem da piloto era totalmente em vidro. O controle destes ensaios foi por meio visual que é bastante significativo pelo fato de ser um controle simnão, isto é, ou tem turbidez ou não tem turbidez. A água residuária entrando no coalescedor era homogênea e na saída do coalescedor havia a formação de duas camadas distintas com uma interface de separação. A camada inferior apresentava uma turvação e a camada superior não apresentava turvação. Este fato mostra de forma inquestionável de que ocorreu um processo de aglutinação de partículas ou coalescência. Desta forma, o objetivo deste trabalho é dar continuidade ao trabalho iniciado em 1984, visando desenvolver uma metodologia para explicar o fenômeno da coalescência neste tipo de coalescedor e também desenvolver um modelo para o seu dimensionamento, visto que o fluxograma do processo já está estabelecido. Este trabalho é assim definido como teórico, uma vez que já existe o trabalho experimental realizado em 1984. A consulta em literatura tem três enfoques: O primeiro é conhecer o fenômeno da coalescência em termos científico. O segundo enfoque foi conhecer o estado da arte da tecnologia de coalescedor. O terceiro foi uma compilação de todos aqueles conhecimentos científicos e tecnológicos julgados pertinentes para a condução deste estudo. Adotouse, neste trabalho, o método de dedução indutiva e a antiga técnica da equação da proporcionalidade para propor um mecanismo e uma equação cinética da coalescência em filme de líquido. Também foi usada a equação da continuidade de NavierStokes para determinar o perfil de concentração das gotas ao longo do filme, visando gerar um modelo de dimensionamento para o coalescedor proposto. Foi constatado que o comportamento de imiscível em água é específico para cada espécie química e também depende da intensidade de energia aplicada ao meio. Por este motivo, a consolidação da tecnologia de separação de gotas de imiscível proposta só poderá ser realizada mediante um estudo numa instalação em escala industrial. Qualquer estudo em escala piloto vem somente confirmar o que já foi realizado e no máximo fornecer valores isolados de concentração de gotas de imiscível / Abstract: Urban and industrial wastewaters always have immiscible chemicals. These immiscibles are chemicals such as edible oils, lubricant oil and petrochemical solvents. The final destinations of these wastewaters is the river. It is very difficult to separate immiscibles with diameter drop less than 40 µm from the wastewater. The best separation technology available today still produces clean water with drops below 20 microns and with immiscible content of 10 mg/l. In 1984 the author of this work accidentally created one coalescence film equipment. The pilot scale test results were successful in separating immiscibles from wastewater in a petrochemical plant. The glass pilot plant operated continuously. The kind of control plant it is visual to detect the turbidity. The homogenous liquid wastewater is fed to the top of the coalescence equipment. The liquid issue. the bottom of equipment had two phases. The lower phase was turbid and the upper phase was not. Unfortunately the investigation was stopped at the time. Based on the research developed in 1984, the objective of this work is to study the phenomena of coalescence of the liquid film and to develop a kinetic coalescence model and a design model for a coalescence equipment. This present work is theoretical based on the experimental date (process flowsheet and design equipment) obtained in 1984. There are three main objectives: the first objective is to understand the coalescence phenomena; the second is to understand the development of coalescer technology; the third is to compile all relevant scientific and technological knowledge for this research. The investigation used the inductive deduction method and the old proportional equation technique to suggest a mechanism and kinetic equation to describe the film coalescence phenomenon. The NavierStokes equation was used to determine the drop concentration profile in the film, in order to produce a way to design the equipment. One conclusion is that each immiscible chemical behave differently in water. The applied energy also plays a role. Another pilot plant will only confirm what has been done and give isolated immiscible products drop concentration / Doutorado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
|
186 |
Sistema combinado filtro anaerobio-biofiltro aerado submerso : avaliação da partida e da nitrificação de esgoto sanitario / Anaerobic filter-aerated submerged biological filter combined system: start-up and nitrification evaluation in sanitary wastewaterDomingues, Ligia Maria 21 February 2005 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T10:54:06Z (GMT). No. of bitstreams: 1
Domingues_LigiaMaria_M.pdf: 3689935 bytes, checksum: 34e7505224ee444054fb9606a9599e36 (MD5)
Previous issue date: 2005 / Resumo: Este trabalho fundamentou-se na concepção, construção e operação de um sistema combinado anaeróbio-aeróbio, constituído de filtro anaeróbio (FA) e biofiltro aerado submerso (BAS), em escala de laboratório, aplicado ao tratamento de esgoto sanitário. Para atingir o objetivo principal de avaliar o desempenho global do sistema, o trabalho foi dividido em 3 etapas: estudo hidrodinâmico, avaliação da partida e avaliação da nitrificação em diferentes TDH. Baseado numa rotina de monitoramento dos parâmetros físicos, químicos e microbiológicos foi possível avaliar e adequar as condições requeridas para a nitrificação. Verificou-se o desempenho do sistema para diferentes taxas de carregamento volumétrico orgânico e de amônia, relacionando-o com as populações de bactérias nitrificadoras existentes. Constatou-se que remoção de matéria orgânica alcançada foi equivalente para os TDH de 8h (média de 86 ± 6 % para 1,89 ± 0,61 kg DQO/m3.dia com DQO efluente de 87 ± 46 mg O2/L) e 10h (média de 87 ± 4 % para 1,88 ± 0,83 kg DQO/m3 dia com DQO efluente de 89 ± 32 mg O2/L). Para TDH total de 8h (4h de aeração) e taxa de carregamento volumétrico de amônia de 0,33 ± 0,05 kg /m3.dia no BAS a remoção de amônia foi de 27 ± 14 % e a nitrificação completa foi de 20 ± 8 %, para 108 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. Para TDH total de 10h (5h de aeração) e taxa de carregamento volumétrico de amônia de 0,39 ± 0,10 kg /m3.dia no BAS a remoção de amônia foi de 47 ± 20 % e a nitrificação foi de 40 ± 19 %, para 1012 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. A concepção do sistema FA-BAS operando com TDH de 10 h foi adequada à nitrificação, quando aplicada ao tratamento de esgoto doméstico com média concentração de amônia (em torno de 30 mg/L). Indicou ainda ter grande potencial para tratar esgoto com maior concentração de amônia (acima de 50 mg/L) / Abstract: The present project was based on the conception, construction and operation of an anaerobic-aerobic combined system. This was formed by an anaerobic filter (AF) and an aerated submerged biofilter (ASB), in a laboratory scale, and used for sanitary wastewater. The main objective of this project was to analyze the general performance of the system, and for that, it was divided in 3 parts: hydrodynamic study, start-up evaluation and nitrification analysis in different HRT. Based on a frequent monitoring of physical, chemical and microbiological parameters, it was possible to evaluate and adequate the required conditions for nitrification. The performance of the system for different organic and ammonia volumetric loading rates were verified. Afterwards it was related to the populations of nitrifying bacteria. The system demonstrated organic matter removal not only for HRT of 8 h (average of 86 ± 6% for 1,89 ± 0,61 kg COD/m3.day, with effluent COD of 87 ± 46 mg O2/L) but also for HRT of 10 h (average of 87 ± 4 % for 1,88 ± 0,83 kg COD/m3.day, with effluent COD of 89 ± 32 mg O2/L). For total HRT of 8 h (4 h of aeration) and volumetric loading rates of ammonia of 0,33 ± 0,05 kg/m3.day at ASB, the ammonia removal was 27 ± 14% and the complete nitrification was 20 ± 8 %, for 108 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. For total HRT of 10 h (5 h of aeration) and volumetric loading rates of ammonia of 0,39 ± 0,10 kg/m3.day at ASB, the ammonia removal was 47 ± 20 % and the complete nitrification was 40 ± 19 %, for 1012 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. The system AF-ASB operated with HRT of 10 h demonstrated to be useful for nitrification if applied to sewage treatment with average concentration of ammonia (around 30 mg/L). It can also be pointed out that the system can be used to treat sewage with higher concentrations (over 50 mg/L) / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
187 |
Proposição de metodologia para determinação de parametros de projeto e operação de reatores biologicos de lodos ativados por bateladaPereira, Renata Ugliani Henrique 08 August 1996 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T13:06:41Z (GMT). No. of bitstreams: 1
Pereira_RenataUglianiHenrique_M.pdf: 2973368 bytes, checksum: fca632d0fdd3c4a40c10b751115ea1a7 (MD5)
Previous issue date: 1996 / Resumo: o uso de reatores biológicos tipo lodos ativados por batelada (LAB), vem sendo intensificado nos últimos anos em vários países, pela sua simplicidade operacional, possibilidade de automação, flexibilidade de estratégias de operação que podem permitir a remoção de nutrientes principalmente (N e P) e obtenção de choques devido aos picos de cargas volumétricas e/ou orgânicas, baixa produção de lodo e alta eficiência de remoção de compostos orgânicos, aliado à economia de energia e implantação comparada com os sistemas de lodos ativados convencionais e suas variantes. No entanto, porém, não existem, parâmetros e modelos matemáticos bem definidos que possam ser aplicados ao projeto e operação desse tipo de sistema, e neste trabalho, apresenta-se e testa-se com sucesso, uma nova modelagem matemática para projeto e operação desse tipo de sistema, além de uma nova metodologia de desenvolvimento de estudos de tratabilidade em reatores piloto, de forma que possam ser estabelecidos parâmetros otimizados que permitam a determinação das seguintes variáveis: a) número ideal de reatores que devem compor uma bateria; b) volume ideal de cada reator; c) parcela do volume total de cada reator que deve ser reservada para preservação do lodo ativado; d) duração ideal de um ciclo total de tratamento e respectivas percentagens desse período destinado às operações de enchimento e reação... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The use of sequencing batch reactors (SBR) of activated sludge has increased in many countries because of the operational simplicity and the automation possibilities. An operacional strategy flexibility allowed nutrients removal (N and P), absortion of volumetric and/or organics load picks, sludge low production and high efficiency of organics compounds. SBR is more economic for building and operation than conventional activated sludges systems. Nevertheless, the SBR system lacks of mathematical parameters and modes definition. In the present work, a new mathematic model to design and operation of this tecnology and a methodology to execute pilot investion in laboratory reactors was tested with success. The new method can predict and optimize the follow parameter: a) reactors number in a full scale wastewater treatment plant; b) volume of each reactors; c) portion of the volume to preserve the sedimented activated sludge at the end of the cyde; d) ideal extend of the total fill and react periods of one cyde treatment... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
|
188 |
Estudo sobre a aplicabilidade da cinetica do tratamento biologico a reatores de lodos ativados por bateladaYamassaki, Claudia Mayumi 31 July 1996 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T14:00:08Z (GMT). No. of bitstreams: 1
Yamassaki_ClaudiaMayumi_M.pdf: 4365383 bytes, checksum: 6e6b0dc5fc3eb0392d0a50a01171c64f (MD5)
Previous issue date: 1996 / Abstract: The use of sequencing batch reactors (SBR) has increased in many countries because of the operational simplicity and the automation possibilities. An operational strategy flexibility allowed nutrients removal (N and P), absortion of volumetric and/or organics load picks, sludge low production and high efficiency of organics compounds. SBR is more economic for building and operation than conventional activated sludges systems. Nevertheless, the SBR system lacks of mathematical parameters and models definition. The present work analysed the kinetic coefficients of aerobic digestion in continuos flow activated sludge. A methodology for the determination of kinetic coefficients for intermitent flow activated sludge, using the sludge age, was tested. The kinetic coefficients were determined for both biologic reactors using chemical painting wastewater. Each reactor has a different coefficient. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
|
189 |
Desempenho do reator batelada sequencial nos processos de nitrificação e desnitrificaçãoMoreira, Mauro de Paula 04 June 2001 (has links)
Orientador : Ranulfo Monte Alegre / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-28T00:35:06Z (GMT). No. of bitstreams: 1
Moreira_MaurodePaula_D.pdf: 27752894 bytes, checksum: 99102d140dea3b370d6d32fe4ca4b978 (MD5)
Previous issue date: 2001 / Resumo: Estudou-se o desempenho de um Reator Batelada Sequencial (RBS) aplicado ao tratamento de água residuária de abatedouro avícola, utilizando várias estratégias de operação, com o objetivo de reduzir a carga carbonácea e promover a remoção dos macronutrientes. Em alguns experimentos, adicionou-se uma fonte de carbono no início da fase anóxica para promover a redução de nitrato por processo de desnitrificação.
No início de cada experimento o reator partia com dois litros de licor misto e era alimentado até que se atingisse quatro litros. Em experimentos com ciclo de 21 horas, nos quais foram adicionados 300 mL de água residuária bruta como fonte de carbono interna no . início da fase anóxica, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 85%, 76%, 32%, 54% e 70% a 25°C, respectivamente. Quando foi utilizada solução de acetato de
sódio de 190 mg DQO/L como fonte de carbono externa, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 72%, 90%, 41%, 65% e 73%, respectivamente. Em experimentos com ciclo de 12 horas, sem fase anóxica, que não foram adicionadas fonte de carbono, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 81%, 86%, 83%, 54% e 72%, respectivamente, sendo esta a estratégia de operação que mostrou ser a mais adequada para remoção de DQO e macronutrientes simultaneamente. Estes resultados mostraram que ocorreu desnitrificação na fase de reação aerada, contrariando informações da literatura que relatam que a desnitrificação ocorre em fase anóxica. A remoção de matéria carbonácea e macronutrientes depende da duração e ordem das etapas, bem como da condição de partida do reator, porém as características da água residuária
bruta e do lodo biológico também influenciam o desempenho do reator / Abstract: The performance of the feed batch reactor applied to poultry wastewater treatment was investigated. Several strategies of reactor operation were used to reduce the carbon demand and macronutrients, inc1udingthe addition of a carbon source at the beginning of the anoxic step to promote the nitrate reduction and the denitrification. At the beginning of each experiment the reactor started with two litres of mixed liquor and it was fed with wastewater until final volume of four litres. The COD, phosphorus,
ammonia, nitrite and nitrate reduction reached 85%, 76%, 32%, 54% and 70% at 25°C, respectively, in experiments with duration of 21 hours in which 300 mL of raw wastewater were added at the beginning of the anoxic step as carbon source. When it was added sodium acetate solution to increase the COD in 190 mg COD/L as carbon source, the reduction of COD, phosphorus, ammonia, nitrite and nitrate reached values of 72%, 90%, 41%, 65% and 73%, respectively. The best operation strategy to simultaneously COD and macronutrients reduction showed to be experiments with 12 hours of duration without anoxic step and addition of carbon source, when the COD, phosphorus, ammonia, nitrite and nitrate reduction reached
81%, 86%, 83%, 54% and 72 , respectively. These results showed that the denitrification occurred in oxic phase despite the literature reports that asseverate that denitrification occurs only in anoxic phase. The duration and order of the steps of the sequencing batch reactor as well the initial
condition at each run beginning influence the carbon and macronutrients remova!, beside the wastewater and sludge characteristics / Doutorado / Doutor em Engenharia de Alimentos
|
190 |
Pos-tratamento de esgoto : sistema sequencial de leitos cultivados (constructed wetlands) vertical e horizontal / Post-treatment of sawage : sequential system of vertical and horizontal constructed wetlandsSantos, Regina Maria Ferreira dos 13 August 2018 (has links)
Orientadores: Denis Miguel Roston, Marcelus Alexander Acorinte Valentim / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-13T08:39:55Z (GMT). No. of bitstreams: 1
Santos_ReginaMariaFerreirados_M.pdf: 5222301 bytes, checksum: 6d989174a6a53d3154acb1d4dba174b2 (MD5)
Previous issue date: 2009 / Resumo: A Região Metropolitana de Campinas - RMC passa hoje por uma situação crítica devido ao comprometimento da qualidade de suas bacias hidrográficas e da forte pressão de demanda. O reúso se mostra como a alternativa mais plausível para satisfazer as demandas menos restritivas, liberando as águas de melhor qualidade para usos mais nobres, como o abastecimento doméstico. Inserida na RMC, mais precisamente na zona rural do Município de Sumaré, encontra-se a área de eventos, Estância Árvore da Vida - EAV. Esta área apresenta uma população fixa de aproximadamente 500 pessoas e uma população variável que pode chegar a até 10.000 pessoas durante os eventos realizados ao longo do ano. Esta propriedade tem como Estação de Tratamento um sistema de Lodos Ativados com disposição do efluente final em corpo d'água. Para melhoria da qualidade do efluente da ETE em funcionamento com vistas ao reúso, este trabalho teve como proposta avaliar um Sistema Sequencial de Pós-Tratamento por Leitos Cultivados (constructed wetland). O sistema piloto compreende: três leitos cultivados; dois de fluxo vertical em paralelo seguidos de um de fluxo horizontal, e na sequencia adaptou-se um canal para cloração do efluente. A desinfecção não faz parte do foco principal do trabalho, sua conotação foi de uma proposta inicial com vistas a estudos posteriores de um dispositivo simples e de baixo custo, que permita a aplicação do desinfetante sem a utilização de energia elétrica. As etapas de campo, construção, cultivo das macrófitas (Typha sp.) e avaliação do sistema, transcorreu ao longo de 11 meses. Os três leitos, construídos de fibra de vidro e possuíam a mesma área superficial, 2,75m2. Em termos operacionais, o sistema teve ótimo desempenho, não apresentou problemas de ordem hidráulica, indícios de colmatação do meio filtrante, odores ou surgimento de plantas invasoras. Os resultados obtidos ao longo da pesquisa apontaram: (i) Potencialidade do Sistema Sequencial (LCFVs seguidos de LCFH) na remoção de 74% de DQO, 88% de P, 97% de Turbidez, 93,5% de Cor, 93,85% de SST; (ii) Remoção de Nitrogênio amoniacal de 57,8% e acréscimo de nitrato de 40% nos LCFVs com maciço filtrante de 0,80m de altura (0,07m de brita 1 no topo, 0,60m de areia média no meio, 0,13m de brita1 no fundo); (iii) Indicação da ocorrencia da nitrificação no LCFH com o crescimento de 48,6% da DBO5 e 13% de nitrato; iv) Perfeita adaptação das macrófitas nos três leitos. Assim, recomenda-se a utilização de Sistema Sequencial de Leitos Cultivados (constructed wetlands) de Fluxo Vertical e Horizontal associado a lodos ativados tratando esgoto doméstico, entretanto, para o reuso do efluente, uma etapa de desinfecção criteriosa é altamente recomendável. / Abstract: The Metropolitan Region of Campinas - MRC faces nowadays a critical situation due to the damaged water quality of the hydrographical basins and its high demand. The reuse appears to be the most plausible alternative to satisfy the less restrictive demands, setting free the water of the best quality to nobler uses, like domestic supply. The area of events Estância Árvore da Vida - EAV is located in the MRC, precisely in the countryside of Sumaré City. This area has a fixed population of about 100 people and a fluctuating population that can reach the amount of 10.000 during the events in the whole year. The property has as a Treatment Station a system of Activated Mud with final effluent disposition in river. In order to improve the quality of the functioning ETE's effluent aiming the reuse, the present work looks forward to evaluating an Integrated System of Post-Treatment by Constructed Wetlands. The pilot system comprehends: three constructed wetlands, two of vertical in parallel flow followed by one of horizontal flow and an effluent's chlorination canal. The disinfection does not consist in the main focus of this work; it's connotation was of an initial proposal looking forward to later studies on a simple and low-cost device, which allows the application of the disinfectant without using electric energy. The field's steps, construction, macrófitas' cultivation Thypha sp. and the system evaluation, occurred during 11 months. The three bottom places were built of glass fiber and they had the same superficial area, 2,75m2. In operational terms, the system had a great performance; there were no hydraulics problems, no clogging of the filtering environment, smelling or rising of invaders plants. The obtained results during the research pointed: (i) Sequential System Potential (LCFVs followed by LCFH) by the removing of 74% of COD, 88% of P, 97% of Turbidity, 93,5% of Color, 93,85% of SST; (ii) Amoniacal nitrogen removing of 57,8% and 40% increasing of nitrate on the LCFVs with 0,80m of filtering material (0,07m of gravel on the top, 0,60m of tiny sand on the middle and 0,13m of gravel on the bottom); (iii) Indication of nitrification occurrence on LCFH with 48,6% growing of BOD5 and 13% of nitrate; iv) Perfect adaptation of the macrophytes on the three bottom places. Therefore it's recommended the use of the Sequential System of constructed wetlands of vertical and horizontal flow associated to activated mud treating domestic sewer, however for the effluent's reuse it's highly recommended a rigorous disinfection procedure. / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
|
Page generated in 0.0594 seconds