1

Bezdrátový přenos výkonu 20 kW / Wireless power transfer 20 kW

Tománek, Radek January 2019 (has links)
This thesis deals with the design of wireless power transfer at a distance of 600 mm dimensioned to 20 kW. The transfer is provided by inductive coupling of resonant circuits with 800 mm diameter coils. It contains a description of the design and calculations of individual parts, stating specific values. It also includes description and schematics of control circuits.
2

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit

Park, Sangtak January 2011 (has links)
An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation range, much less than its entire gap. To provide effective solutions to these problems, we present complete analytical and numerical models of various electrostatic actuators coupled with resonant drive circuits that are able to drive electrostatic actuators at much lower input voltage than that of conventional actuation methods and to extend their operation range beyond their conventional pull-in points in the presence of high parasitic capacitance. Moreover, in order to validate the analytical and numerical models of various electrostatic actuators coupled with the resonant drive circuits, we perform the experiment on the microplate and the micromirror coupled with the resonant drive circuit. For instance, using a high voltage amplifier, we manage to rotate the micromirror with sidewall electrodes by 6 ° at 180 V. However, using the resonant drive circuit, we are able to rotate the same micromirror by 6 ° at much lower input voltage, 8.5 V. In addition, the presented work also facilitates the stability analysis of electrostatic actuators coupled with the resonant drive circuits and provides how the effect of the parasitic capacitance can be minimized. For example, the resonant drive circuit placed within a positive feedback loop of a variable gain amplifier is able to extend the operation range much further even in the presence of very high parasitic capacitance. The resonant drive circuit with the proposed feedback controllers is also able to minimize the detrimental effects of the parasitic capacitance and to displace a parallel-plate actuator over its entire gap without the saddle-node bifurcation. Finally, we present a new displacement measurement method of electrostatic actuators coupled with the resonant drive circuits by sensing the phase delay of an actuation voltage with respect to an input voltage. This new measurement method allows us to easily implement feedback control into existent systems employing an electrostatic actuator without any modification or alteration to the electrostatic actuator itself. Hence, this research work presents the feasibility of electrostatic actuators coupled with the resonant drive circuit in various industrial and medical applications, in which the advantages of miniaturization, low supply voltage, and low power consumption are greatly appreciated.
3

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit

Park, Sangtak January 2011 (has links)
An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation range, much less than its entire gap. To provide effective solutions to these problems, we present complete analytical and numerical models of various electrostatic actuators coupled with resonant drive circuits that are able to drive electrostatic actuators at much lower input voltage than that of conventional actuation methods and to extend their operation range beyond their conventional pull-in points in the presence of high parasitic capacitance. Moreover, in order to validate the analytical and numerical models of various electrostatic actuators coupled with the resonant drive circuits, we perform the experiment on the microplate and the micromirror coupled with the resonant drive circuit. For instance, using a high voltage amplifier, we manage to rotate the micromirror with sidewall electrodes by 6 ° at 180 V. However, using the resonant drive circuit, we are able to rotate the same micromirror by 6 ° at much lower input voltage, 8.5 V. In addition, the presented work also facilitates the stability analysis of electrostatic actuators coupled with the resonant drive circuits and provides how the effect of the parasitic capacitance can be minimized. For example, the resonant drive circuit placed within a positive feedback loop of a variable gain amplifier is able to extend the operation range much further even in the presence of very high parasitic capacitance. The resonant drive circuit with the proposed feedback controllers is also able to minimize the detrimental effects of the parasitic capacitance and to displace a parallel-plate actuator over its entire gap without the saddle-node bifurcation. Finally, we present a new displacement measurement method of electrostatic actuators coupled with the resonant drive circuits by sensing the phase delay of an actuation voltage with respect to an input voltage. This new measurement method allows us to easily implement feedback control into existent systems employing an electrostatic actuator without any modification or alteration to the electrostatic actuator itself. Hence, this research work presents the feasibility of electrostatic actuators coupled with the resonant drive circuit in various industrial and medical applications, in which the advantages of miniaturization, low supply voltage, and low power consumption are greatly appreciated.
4

MEMS-Laser-Display-System / MEMS Laser Display System

Specht, Hendrik 19 October 2011 (has links) (PDF)
In der vorliegenden Arbeit werden die im Zusammenhang mit der Strahlablenkung stehenden Systemaspekte der auf MEMS-Scanner basierenden Laser-Display-Technologie theoretisch analysiert und aus den Ergebnissen die praktische Implementierung eines Laser-Display-Systems als Testplattform vorgenommen. Dabei werden mit einem Ansatz auf Basis zweier 1D-Scanner und einem weiteren Ansatz mit einem 2D-Scanner zwei Varianten realisiert. Darüber hinaus erfolgt die Entwicklung eines bildbasierten Multiparametertestverfahrens, welches sowohl für den Test komplettierter Strahlablenkeinheiten bzw. Projektionsmodule als auch zum umfassenden und zeiteffizienten Test von MEMS-Scannern auf Wafer-Level geeignet ist. Mit diesem Verfahren erfolgt eine Charakterisierung der zwei realisierten Varianten des Laser-Displays. Ausgehend von den Eigenschaften des menschlichen visuellen Systems und den daraus resultierenden Anforderungen an das Bild sowie einer systemtheoretischen Betrachtung des mechanischen Verhaltens von MEMS-Scannern bildet die Ansteuersignalerzeugung für den resonanten Betrieb der schnellen und den quasistatischen Betrieb der langsamen Achse einen Schwerpunkt. Neben dem reinen digitalen Regler- bzw. Filterentwurf sowie mehreren Linearisierungsmaßnahmen beinhaltet dieser auch die Herleitung einer FPGA-basierten Videosignalverarbeitung zur Konvertierung von Scannpattern, Zeitregime und Auflösung mit einer entsprechenden Synchronisierung von Strahlablenkung und Lasermodulation. Auf Grundlage der daraus resultierenden Erkenntnisse über den Zusammenhang zwischen Scanner-/Systemparametern und Bildparametern werden Testbild-Bildverarbeitungsalgorithmus-Kombinationen entwickelt und diese, angeordnet in einer Sequenz, mit einem Kalibrierverfahren zu einem Testverfahren für MEMS-Scanner vervollständigt. Die Ergebnisse dieser Arbeit entstanden im Rahmen von industriell beauftragten F&E-Projekten und fließen in die andauernde Fortführung des Themas beim Auftraggeber ein.
5

MEMS-Laser-Display-System: Analyse, Implementierung und Testverfahrenentwicklung

Specht, Hendrik 20 May 2011 (has links)
In der vorliegenden Arbeit werden die im Zusammenhang mit der Strahlablenkung stehenden Systemaspekte der auf MEMS-Scanner basierenden Laser-Display-Technologie theoretisch analysiert und aus den Ergebnissen die praktische Implementierung eines Laser-Display-Systems als Testplattform vorgenommen. Dabei werden mit einem Ansatz auf Basis zweier 1D-Scanner und einem weiteren Ansatz mit einem 2D-Scanner zwei Varianten realisiert. Darüber hinaus erfolgt die Entwicklung eines bildbasierten Multiparametertestverfahrens, welches sowohl für den Test komplettierter Strahlablenkeinheiten bzw. Projektionsmodule als auch zum umfassenden und zeiteffizienten Test von MEMS-Scannern auf Wafer-Level geeignet ist. Mit diesem Verfahren erfolgt eine Charakterisierung der zwei realisierten Varianten des Laser-Displays. Ausgehend von den Eigenschaften des menschlichen visuellen Systems und den daraus resultierenden Anforderungen an das Bild sowie einer systemtheoretischen Betrachtung des mechanischen Verhaltens von MEMS-Scannern bildet die Ansteuersignalerzeugung für den resonanten Betrieb der schnellen und den quasistatischen Betrieb der langsamen Achse einen Schwerpunkt. Neben dem reinen digitalen Regler- bzw. Filterentwurf sowie mehreren Linearisierungsmaßnahmen beinhaltet dieser auch die Herleitung einer FPGA-basierten Videosignalverarbeitung zur Konvertierung von Scannpattern, Zeitregime und Auflösung mit einer entsprechenden Synchronisierung von Strahlablenkung und Lasermodulation. Auf Grundlage der daraus resultierenden Erkenntnisse über den Zusammenhang zwischen Scanner-/Systemparametern und Bildparametern werden Testbild-Bildverarbeitungsalgorithmus-Kombinationen entwickelt und diese, angeordnet in einer Sequenz, mit einem Kalibrierverfahren zu einem Testverfahren für MEMS-Scanner vervollständigt. Die Ergebnisse dieser Arbeit entstanden im Rahmen von industriell beauftragten F&E-Projekten und fließen in die andauernde Fortführung des Themas beim Auftraggeber ein.