• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 119
  • 71
  • 65
  • 44
  • 43
  • 32
  • 30
  • 25
  • 24
  • 24
  • 22
  • 21
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação clínica de restaurações de lesões cervicais não cariosas. / CLINICAL EVALUATION OF RESTORATIONS IN NON-CARIOUS CERVICAL LESIONS

Santiago, Sérgio Lima 05 July 2002 (has links)
Avaliou-se o desempenho clínico de um sistema restaurador adesivo (Excite – Tetric Ceram/ Vivadent) e do cimento de ionômero de vidro modificado por resina (Vitremer/ 3M) na restauração de lesões cervicais não cariosas por meio do sistema de avaliação do USPHS modificado. Um total de setenta restaurações, trinta e cinco por material, foi realizado por um único operador em trinta pacientes voluntários com idades de 23 a 68 anos. Previamente à execução das restaurações, foi realizada uma profilaxia com pedra-pomes e água a fim de remover quaisquer resíduos. As lesões cervicais não foram submetidas a qualquer tipo de preparo cavitário, sendo restauradas sob isolamento absoluto e de acordo com as instruções do fabricante. Todas as restaurações foram avaliadas pelo método direto por dois examinadores nos intervalos de tempo estipulados: inicial (baseline), 6 meses, 1 ano e 2 anos usando os critérios de retenção, integridade marginal, descoloração marginal, manutenção da forma anatômica (desgaste), cárie secundária e sensibilidade pós-operatória. Ao final de dois anos, os resultados de restaurações clinicamente satisfatórios (escores Alfa e Bravo) obtidos para a resina composta e cimento de ionômero de vidro modificado por resina foram respectivamente: retenção (79%, 100%); integridade marginal (100%, 100%); descoloração marginal (100%, 100%); desgaste (96%, 100%); cárie secundária (100%, 100%) e sensibilidade pós-operatória (100%, 100%). Os resultados foram submetidos à análise estatística com o teste exato de Fisher ou o teste Quiquadrado de Pearson com nível de significância de 5% (p<0,05). As comparações intragrupos foram realizadas com o teste de McNemar com nível de significância de 5%. Com base na análise estatística dos resultados concluiu-se que houve diferença estatisticamente significante entre os materiais no critério retenção no período de 2 anos, sendo que nos demais critérios os dois materiais não apresentaram diferenças estatisticamente significante. / The purpose of this study was to assess the clinical performance of a monocomponent adhesive system (Excite/Tetric-Ceram Vivadent) and a resin-modified glass ionomer cement (Vitremer – 3M) to restore non-carious cervical lesions using a modified USPHS system. A total of 70 restorations (thirty-five per material) were performed by one operator in 30 patients 23-68 aged. Prior to restorations, teeth were pumiced with a prophy cup and restored following manufacturer’s instructions. All restorations were directly evaluated by two examiners at baseline, 6 months, 1 year and 2 years using the following: retention, marginal integrity, marginal discoloration, wear, recurrent caries postoperative and sensitivity. After two years. The ratings (Alpha and Bravo) of clinical satisfactory restorations were as follows (Tetric-Ceram/Vitremer): retention (79%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (96%/100%), recurrent caries (100%/100%) and postoperative sensitivity (100%/100%). Statistical analysis was completed with Fisher’s exact or Pearson Chi-square tests at a significance level of 5% (P<0.05). Intra-groups comparison was completed with McNemar’s test at a significance level of 5% (P<0.05). Results showed that all restorations of resinmodified glass ionomer cement were clinically satisfactory and there was significant difference between materials in retention criterion at 2 years of evaluation.
12

Efeito do bisel na infiltração marginal em restaurações classe IV de resina composta

Mizuno, Sérgio Katsuo 14 February 2003 (has links)
O objetivo deste estudo foi avaliar o efeito do bisel na infiltração marginal em restaurações de resina composta em cavidades Classe IV sem e com bisel em todo ângulo cavossuperficial, submetidas à ciclagem térmica e mecânica. Foram preparadas nas mesmas dimensões, variando na ausência ou presença de bisel, 30 cavidades de Classe IV em incisivos inferiores de bovinos. No grupo 1 não foi realizado bisel e no grupo 2 o bisel foi realizado com uma extensão aproximada de 1,0 mm ao redor de todo o ângulo cavossuperficial. As cavidades foram restauradas com o mesmo sistema adesivo e resina composta Single Bond Z-250 (3M). Após a restauração foi executado um acabamento inicial com lâminas de bisturi. Em seguida, os dentes foram armazenados em água deionizada a uma temperatura de 37ºC durante sete dias. No sétimo dia foi realizada a complementação do acabamento e polimento. Os grupos foram submetidos à ciclagem térmica com o tempo de imersão de 30 segundos em cada banho, a uma temperatura de 5 ºC e 55ºC, por 500 ciclos. Logo após, os corpos-de-prova foram submetidos à ciclagem mecânica, utilizando a máquina universal de ensaio EMIC programada para executar um carregamento e descarregamento axial de compressão na face lingual de cada dente restaurado. Inicialmente, foi aplicada uma carga ascendente de 1 a 10 kgf e descendente de 10 a 1 kgf durante 30 segundos, perfazendo um total de 100 ciclos para cada corpo-de-prova. Durante este ensaio, a porção coronária dos dentes ficou submersa em fucsina básica a 0,5 %. Após o término da ciclagem mecânica, os corpos-de-prova permaneceram por mais 24 horas mergulhados na mesma solução e, em seguida, foram lavados em água corrente por 12 horas. Cada dente foi seccionado em fatias transversais de aproximadamente 1,0 mm, sendo selecionada a fatia que apresentou maior grau de infiltração. Para avaliação da infiltração marginal foi utilizado um programa de análise de imagens, Image Tools, no qual foi medida a extensão da penetração do corante em milímetros. Os valores em milímetros da extensão de penetração do corante foram para os grupos 1 e 2; sendo 1,02 mm e 0,0 mm respectivamente. Aplicando o teste estatístico, verificou-se que houve diferença estatisticamente significante (p < 0,05) entre os valores de infiltração do grupo 1 (ausência de bisel) com os do grupo 2 (presença de bisel). Concluiu-se que a presença do bisel diminui significativamente a infiltração marginal nas restaurações de Classe IV, restaurações estas confeccionadas com o sistema restaurador adesivo e resina composta. / The purpose of this study was to evaluate the effect of bevel in the microleakage in restorations of composite resin, in cavities Class IV with bevel and without bevel around all the cavosurface margins, submitted to a thermal and mechanical cycled. The same dimensions was prepared, varying in the bevel presence or absence, thirty cavites of Class IV bovine teeth. Thereby, in group 1 the bevel was not done and in group 2 the bevel of 1 mm length was done around all the cavosurface margins. The cavities was restored with Single Bond / Z-250 (3 M). After restored, all restorations were finished with a scalpel. Afterwards, they were stored in deionize water at 37º C for seven days followed by the polishing procedures. All the groups were submitted to thermocycling 500 times between 5 ºC and 55 ºC, in a 30 seconds dwell time. For the mechanical cycled test, it was used the EMIC machine which was programmed to execute an axial load of 10 kgf, during 30 seconds in the lingual surface of the restorations. During the mechanical cycled test, the crown of the teeth remained submerse in a 0,5% basic fuchsin, and continued submerse until 24 hours had been completed. After that, the teeth were left 12 hours in the running water, followed by the section. Each tooth was parted in transversal sections with approximately 1,0 mm and the section with the higher amount of dye penetration was selected. It was used a program (Image Tool) to make possible an analysis of the images, to determined the dye penetration in milimeters. Through the results it is clearly that, there was a significant statistic difference (p < 0,05) between group 1 (absence of bevel) and group 2 (presence of bevel), which had 1,02 mm and 0,0 mm averages of dye penetration respectively. It was concluded that the procedure of bevel execution reduce expressively the microleakage around the margins of the restorations.
13

Estudo da degradação microbiana in vitro do Poli (1,4-trans-isopreno) (in natura) e em cones dentários. / Study of in vitro degradation of poly (1,4-trans-isoprene)(in nature)and in dental cones

Souza, Lute Rafael de January 2012 (has links)
SOUZA, L. R. Estudo da degradação microbiana in vitro do Poli (1,4-trans-isopreno) (in natura) e em cones dentários. 2012. 80 f. Dissertação (Mestrado em Química) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-11-24T21:40:13Z No. of bitstreams: 1 2012_dis_lrsouza.pdf: 1340876 bytes, checksum: 7896c730622fb70cb15cf7a6f3caedb4 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-01-27T22:32:46Z (GMT) No. of bitstreams: 1 2012_dis_lrsouza.pdf: 1340876 bytes, checksum: 7896c730622fb70cb15cf7a6f3caedb4 (MD5) / Made available in DSpace on 2016-01-27T22:32:46Z (GMT). No. of bitstreams: 1 2012_dis_lrsouza.pdf: 1340876 bytes, checksum: 7896c730622fb70cb15cf7a6f3caedb4 (MD5) Previous issue date: 2012 / The gutta-percha cones used in endodontic therapy, consisting of poly (1,4-trans-isoprene), ZnO and/or BaSO4 and wax/resin, were meant to last a lifetime in root canals filled by them. However, there is evidence that these materials suffer degradation with the passage of time when there shutter intensified infections by microorganisms. The bacterium Enterococcus faecalis is one of those microorganisms commonly associated with persistent periapical infections. The prevalence of this bacterium in cases of re-treatment is between 29% and 79% of cases. The objective is to study the bacterial degradation of gutta-percha in medium containing E. faecalis, with the focus on organic matter, polyisoprene. Each sample cone was immersed in mineral salts medium with inoculum concentration of 5.4 x 105 CFU/mL for periods of 10 to 100 days. The cones were removed from contact with the inoculum at various times and analized. Were weighed and characterized by TGA, GPC, FTIR, NMR H1 and SEM. The growth of the inoculum was monitored by optical density measurements, determining of percentage of mineralization of CO2, measured dry biomass cells, measurements of pH and cell count. The antimicrobial activity of inorganic constituents of cones was verified by diffusion test pit. Was observed gradual loss of mass of the cones with the degradation time. The increase in the ash content at 800 °C, shows that there was a progressive loss of organic matter and an increased proportion of inorganic constituents. After contact with E. faecalis, polyisoprene isolated cones marks Odous® and Tanari® was analized and compared and the fresh polyisoprene by GPC and FTIR. The results show that in all three cases there is small and gradual loss of the molar mass of the polyisoprene constituents of material, the more evidente in polyisoprene in nature. Infrared spectra show that degradation also ocurrs with strutural modifications of the polymer, especially in the occurrence of deformation bands of C=O and OH/OOH, and variations in the pattern of cristalinity of the bands of C=C-H. The SEM images show that changes may ocurr in the surface morphology of the cones biodegraded, resulting the from selective attack to the organic component. The NMR H1 spectra of polyisoprene fresh show that the material has undergone minor structural changes in the molecules of polyisoprene during bioassay. All bioassays monitoring indicated that the inoculum grows continuously during the period of contact with the cones or polyisoprene in nature. The bacteria degrades the organic matter of the cones using them as a source of substrate and thereby causing voids cones that can cause failure in endodontic treatment. / Os cones de guta-percha usados em endodontia, compostos de poli (1,4-trans-isopreno), ZnO e/ou BaSO4 e ceras/resinas, foram feitos para durar a vida inteira nos canais radiculares por eles preenchidos. Entretanto, existem evidências de que esses materiais sofrem degradação com o decorrer do tempo de obturação intensificada quando existem infecções por microrganismos. A bactéria Enterococcus faecalis é um desses microrganismos, normalmente associada com infecções periapicais persistentes. A prevalência dessa bactéria em casos de re-tratamento ocorre entre 29 e 79% dos casos. O objetivo do trabalho é estudar a degradação bacteriana de cones de guta-percha em meio contendo E. faecalis, com o foco na matéria orgânica, o poliisopreno. Cada amostra de cone foi imersa em meio de sais minerais com inóculo de concentração de 5,4x105 UFC/mL por períodos de 10 a 100 dias. Os cones foram removidos do contato com o inóculo em tempos variados e analisados. Foram pesados e caracterizados por TGA, GPC, FTIR, MEV e RMN H1. O crescimento do inoculo foi monitorado através de medidas de densidade óptica, determinação da porcentagem de mineralização de CO2, medidas da biomassa seca de células, medidas de pH e contagem de células. A atividade antimicrobiana dos constituintes inorgânicos dos cones foi verificada mediante o teste de difusão em poço. Foi observada perda gradual de massa dos cones com o tempo de degradação. O aumento no teor de resíduos em 800°C, mostra que houve uma perda progressiva de matéria orgânica e um aumento na proporção de constituintes inorgânicos. Após o contato com E. faecalis, o poliisopreno isolado dos cones das marcas Odous® e Tanari® foi analisado e comparado com o poliisopreno in natura por GPC e FTIR. Os resultados mostram que nos três casos ocorre uma pequena e gradual perda de massa molar do poliisopreno constituintes do material, mais evidenciada no poliisopreno in natura. Os espectros de infravermelho mostram que a degradação também ocorre com modificações estruturais do polímero, especialmente no surgimento de bandas de deformação de C=O e OH/OOH; e variações no padrão de cristalinidade das bandas de C=C-H. As imagens de MEV mostram que podem ocorrer mudanças na morfologia da superfície dos cones biodegradados, resultado do ataque seletivo ao componente orgânico. Os espectros de RMN de H1 do poliisopreno in natura mostram que o material sofreu pequenas mudanças estruturais nas moléculas de poliisopreno durante o bioensaio. Todos os bioensaios de monitoramento indicaram que o inóculo cresce continuamente durante o período de contato com os cones ou com o poliisopreno in natura. A bactéria degrada a matéria orgânica dos cones usando-os como fonte de substrato e, consequentemente, causando vazios nos cones que podem ocasionar falhas no tratamanto endodôntico.
14

Efeito do selamento, reparo e recontorno sobre a longevidade de restaurações de resina composta em dentes posteriores segundo critério USPHS/RYGE

Fernández Godoy, Eduardo Maximiliano [UNESP] 15 July 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-15. Added 1 bitstream(s) on 2016-12-09T13:54:49Z : No. of bitstreams: 1 000867872.pdf: 1681629 bytes, checksum: 8c8d0ef7b0cc0f0f1c1d43325e7ab114 (MD5) / O objetivo geral deste trabalho foi determinar o efeito de selamento marginal, recontorno e reparo sobre a longevidade de restaurações de resina composta em dentes posteriores segundo Critério USPHS/Ryge. Foi realizado estudo experimental, longitudinal, prospectivo triplo-cego, incluímos 107 restaurações de resina composta de um grupo de 26 pacientes, de ambos os gêneros. Todos os pacientes foram recrutados na clínica da faculdade de Odontologia da Universidade do Chile em 2003 de acordo com os seguintes critérios de inclusão: apresentar restaurações de resina composta em dentes posteriores com defeitos, apresentando uma ou mais características clínicas classificadas como Bravo ou Charlie acordo com critérios USPHS/Ryge.Foram constituídos os seguintes grupos experimentais: 1.- Selamento, 2.- recontorno, 3.- Reparação, 4.- substituição, 5.- Sem intervenção.Os dentes dos voluntários foram avaliados e classificados pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (0.75), A longevidade das restaurações foi avaliada antes da intervenção e após 1, 2, 3, 4, 5 e 10 anos de observação. Resultados, em geral, os grupos estudados mostraram restaurações clinicamente aceitáveis após dez anos de acompanhamento. O selamento e o recontorno mostraram efeito de melhoria imediata, que se perdeu ao longo do tempo (p<0.05). O reparo foi efetivo e apresentou resultados semelhantes a substituição total da restauração após 10 anos de uso clínico (p>0.05). Conclusão: O reparo aumentou a longevidade da restauração de resina composta em dentes posteriores por 10 anos enquanto o recontorno e o selamento marginal mostraram benefícios somente até 4 anos. Estes procedimentos minimamente invasivos mostraram-se validos e poderiam ser adotados pelos programas de saúde pública e pela faculdade...(Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to determine the effect of marginal sealing, refurbishing and repair on the longevity of composite resin restorations in posterior teeth by criteria USPHS / Ryge. This clinical trial was longitudinal, tripleblind prospective. Were included 107 composite restorations of a group of 26 patients, of both genders. All patients were recruited in the clinic of Dentistry faculty of the University of Chile in 2003 according to the following inclusion criteria: presenting composite restorations in posterior teeth with defects, showing one or more clinical features classified as Bravo or Charlie according to USPHS / Ryge. According following criteria constituted the groups: 1.-Sealing, 2.-Refurbished 3. Repair, 4. No treatment and 5. Replacement. The restorations were evaluated and classified by USPHS criteria / Ryge by two trained and calibrated examiners (kappa 0.75), longevity of restorations was evaluated before the intervention and after 1, 2, 3, 4, 5 and 10 years. Results, in general, the groups showed restorations values acceptable to the ten year follow-up in the repair group, sealed and refurbished, the improvements were immediate and the effect remained se. Conclusions: Alternative treatments repair, sealing and refurbishing were able to improve some parameters deteriorated...(Complete abstract electronic access below)
15

Influência do design de restaurações endocrown em CAD/CAM na carga máxima de carregamento em molares tratados endodonticamente

Modena, Cláudia Freitas de Moura January 2015 (has links)
Made available in DSpace on 2016-04-08T03:07:19Z (GMT). No. of bitstreams: 1 000477941-Texto+Parcial-0.pdf: 609 bytes, checksum: 561d326f021051e1a109fba17cc15392 (MD5) Previous issue date: 2015 / Objectives: To evaluate in vitro the influence of different cavity design preparations for endocrown restorations on the fracture resistance of endodontically treated molars. Materials and methods: Fifty extracted healthy third molars were divided randomly into 5 groups (n= 10 per group): H= healthy, F1= 1 ferrule, F2= 2 ferrules (buccal and palatal), FT= total ferrule and NF= flat plateau. The teeth were submitted to root canal treatment after which the cavity preparations were made. The crowns of endocrown, in Lava Ultimate, were manufactured with the CAD-CAM CEREC/INLAB system and cemented with Single Bond Universal and Rely X Ultimate. The resistance to fracture testing was made in a universal testing machine with a speed of 1mm/min. The pattern of failure was then evaluated, taking into consideration only the presence or absence of fracture in the pulp floor. Results: (Means followed by the same letter do not differ statistically for ANOVA and Tukey): H:3970N ab; F1:3170N ab; F2: 3786N ab; TF: 2894N b; NF:4416N a. The most prevalent pattern of failure was the type recoverable in all groups. Conclusions: The type of cavity preparation for endocrown restoration may influence the fracture resistance of endodontically treated molars. The type of ferrule may determine the greater resistance to loading. The pattern of failure was predominantly recoverable. / Objetivos: avaliar in vitro a influência de diferentes designs de preparos cavitários para restaurações endocrown, na resistência máxima ao carregamento de molares endodonticamente tratados. Materiais e métodos: Cinquenta terceiros molares hígidos e extraídos foram divididos aleatoriamente em 5 grupos (n= 10 por grupo), H= hígido, F1= 1 férula, F2 = 2 férulas VL(vestibular e lingual), FT= férula total e SF= platô reto. Os dentes foram submetidos à endodontia e, após, realizados os preparos cavitários. As coroas de endocrown, em Lava Ultimate, foram confeccionadas através do sistema CAD-CAM CEREC/INLAB e cimentadas com Single Bond Universal e Rely X Ultimate. O ensaio de resistência à fratura foi realizado em uma máquina de ensaios universal com velocidade de 1mm/min até o rompimento do corpo de prova. Após, foi avaliado o padrão de falha o qual levou em consideração apenas a presença ou não de fratura do assoalho pulpar. Resultados: (médias seguidas de mesma letra não apresentam diferença estatística para ANOVA e Tukey): H:3970N AB; F1:3170N AB; F2: 3786N AB; FT 2894N B; SF:4416N A. O padrão de falha predominante foi do tipo fratura da restauração em todos os grupos. Conclusões: o tipo de preparo cavitário para restaurações endocrown pode influenciar na resistência à fratura de molares tratados endodonticamente. O tipo de férula utilizada pode determinar maior resistência ao carregamento. O padrão de falha foi predominantemente recuperável.
16

Efeito do selamento, reparo e recontorno sobre a longevidade de restaurações de resina composta em dentes posteriores segundo critério USPHS/RYGE

Fernández Godoy, Eduardo Maximiliano. January 2015 (has links)
Orientador: Osmir Batista de Oliveira Junior / Co-orientador: / Banca: Hermes Pretel / Banca: Andréa Abi Rached Dantas / Banca: Cláudia Silami de Magalhães / Banca: Allyson Nogueira Moreira / Resumo: O objetivo geral deste trabalho foi determinar o efeito de selamento marginal, recontorno e reparo sobre a longevidade de restaurações de resina composta em dentes posteriores segundo Critério USPHS/Ryge. Foi realizado estudo experimental, longitudinal, prospectivo triplo-cego, incluímos 107 restaurações de resina composta de um grupo de 26 pacientes, de ambos os gêneros. Todos os pacientes foram recrutados na clínica da faculdade de Odontologia da Universidade do Chile em 2003 de acordo com os seguintes critérios de inclusão: apresentar restaurações de resina composta em dentes posteriores com defeitos, apresentando uma ou mais características clínicas classificadas como Bravo ou Charlie acordo com critérios USPHS/Ryge.Foram constituídos os seguintes grupos experimentais: 1.- Selamento, 2.- recontorno, 3.- Reparação, 4.- substituição, 5.- Sem intervenção.Os dentes dos voluntários foram avaliados e classificados pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (0.75), A longevidade das restaurações foi avaliada antes da intervenção e após 1, 2, 3, 4, 5 e 10 anos de observação. Resultados, em geral, os grupos estudados mostraram restaurações clinicamente aceitáveis após dez anos de acompanhamento. O selamento e o recontorno mostraram efeito de melhoria imediata, que se perdeu ao longo do tempo (p<0.05). O reparo foi efetivo e apresentou resultados semelhantes a substituição total da restauração após 10 anos de uso clínico (p>0.05). Conclusão: O reparo aumentou a longevidade da restauração de resina composta em dentes posteriores por 10 anos enquanto o recontorno e o selamento marginal mostraram benefícios somente até 4 anos. Estes procedimentos minimamente invasivos mostraram-se validos e poderiam ser adotados pelos programas de saúde pública e pela faculdade...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the effect of marginal sealing, refurbishing and repair on the longevity of composite resin restorations in posterior teeth by criteria USPHS / Ryge. This clinical trial was longitudinal, tripleblind prospective. Were included 107 composite restorations of a group of 26 patients, of both genders. All patients were recruited in the clinic of Dentistry faculty of the University of Chile in 2003 according to the following inclusion criteria: presenting composite restorations in posterior teeth with defects, showing one or more clinical features classified as Bravo or Charlie according to USPHS / Ryge. According following criteria constituted the groups: 1.-Sealing, 2.-Refurbished 3. Repair, 4. No treatment and 5. Replacement. The restorations were evaluated and classified by USPHS criteria / Ryge by two trained and calibrated examiners (kappa 0.75), longevity of restorations was evaluated before the intervention and after 1, 2, 3, 4, 5 and 10 years. Results, in general, the groups showed restorations values acceptable to the ten year follow-up in the repair group, sealed and refurbished, the improvements were immediate and the effect remained se. Conclusions: Alternative treatments repair, sealing and refurbishing were able to improve some parameters deteriorated...(Complete abstract electronic access below) / Doutor
17

Avaliação da resistência à fratura de coroas CAD-CAM sobre pilares sólidos

Stona, Deborah January 2014 (has links)
Made available in DSpace on 2014-07-19T02:02:56Z (GMT). No. of bitstreams: 1 000459296-Texto+Completo-0.pdf: 283193 bytes, checksum: 3d97b7d2dd51eab591a5bbae03076040 (MD5) Previous issue date: 2014 / The aim of the study was to evaluate the fracture resistance of ceramic crowns using Cerec CAD-CAM system on solid pillars. Sixty replica synocta implant and RN solid abutment were embedded in acrylic resin, being randomly assigned (n=20 per group). Three types of ceramics were used: Mark II (feldspar), IPS Empress CAD (leucite) and IPS e. max CAD (lithium disilicate). The crowns were fabricated by CAD-CAM system using the Cerec software version 4. 1. After receiving glaze and were cemented with RelyX U200 cement under load of 1 Kg Half of the specimens of each ceramic was subjected to endurance EMIC DL-2000 test fracture in a universal testing machine with a speed of 1 mm / minute and the other half after 1,000,000 cycles of mechanical stress with a load of 100 N. According to two-way ANOVA, the interaction between the material and mechanical cycling was significant (p = 0. 0001). According to Tukey test (α = 5%) the fracture toughness without mechanical cycling and mechanical cycling, respectively, of Mark II (405N/454N) was statistically lower than ceramic IPS Empress CAD (1169N/1240N) and IPS e. max CAD (1378N/1025N) (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD not differ statistically (p > 0. 05). There was no statistical difference in the resistance to cyclic loading with and without fracture to the Mark II and IPS Empress CAD (p > 0. 05, Student's t test) ceramics. For ceramic IPS e. max CAD, the fracture resistance without mechanical cycling was statistically superior to that obtained with cycling (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD showed higher fracture resistance compared to ceramic Mark II. The cyclic loading negatively influenced only IPS e. max CAD. / O objetivo do estudo foi avaliar a resistência à fratura de coroas cerâmicas utilizando o sistema CAD-CAM Cerec sobre pilares sólidos. Sessenta réplicas de implante synocta RN e pilar sólido foram incluídos em resina acrílica autopolimerizável, sendo divididas aleatoriamente (n=20 por grupo). Três tipos de cerâmicas foram utilizadas: Mark II (feldspática), IPS Empress CAD (leucita) e IPS e. max CAD (dissilicato de lítio). As coroas foram confeccionadas através do sistema CAD-CAM utilizando o software Cerec versão 4. 1. Após receberam glaze e foram cimentadas com RelyX U200 sob carga de cimentação de 1 Kg. Metade dos corpos de prova de cada cerâmica foi submetida ao teste de resistência à fratura em máquina de ensaio universal EMIC-DL 2000 com velocidade de 1 mm/minuto e, a outra metade, após 1. 000. 000 de ciclos de fadiga mecânica com carga de 100 N. Segundo ANOVA de duas vias, a interação entre material e ciclagem mecânica foi significativa (p=0,0001). De acordo com o teste de Tukey (α=5%) a resistência à fratura, sem ciclagem mecânica e com ciclagem mecânica respectivamente, da cerâmica Mark II (405N/454N) foi estatisticamente menor que as cerâmicas IPS Empress CAD (1169N/1240N) e IPS e. max CAD (1378N/1025N) (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD não diferiram estatisticamente entre si (p>0,05). Não houve diferença estatística na resistência à fratura sem e com ciclagem mecânica para as cerâmicas Mark II e IPS Empress CAD (p>0,05, teste t-student). Para a cerâmica IPS e. max CAD, a resistência à fratura sem ciclagem mecânica foi estatisticamente superior à obtida com ciclagem (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD apresentaram maior resistência à fratura quando comparadas com a cerâmica Mark II. A ciclagem mecânica influenciou negativamente apenas a cerâmica IPS e. max CAD.
18

Efeito do bisel na infiltração marginal em restaurações classe IV de resina composta

Sérgio Katsuo Mizuno 14 February 2003 (has links)
O objetivo deste estudo foi avaliar o efeito do bisel na infiltração marginal em restaurações de resina composta em cavidades Classe IV sem e com bisel em todo ângulo cavossuperficial, submetidas à ciclagem térmica e mecânica. Foram preparadas nas mesmas dimensões, variando na ausência ou presença de bisel, 30 cavidades de Classe IV em incisivos inferiores de bovinos. No grupo 1 não foi realizado bisel e no grupo 2 o bisel foi realizado com uma extensão aproximada de 1,0 mm ao redor de todo o ângulo cavossuperficial. As cavidades foram restauradas com o mesmo sistema adesivo e resina composta Single Bond Z-250 (3M). Após a restauração foi executado um acabamento inicial com lâminas de bisturi. Em seguida, os dentes foram armazenados em água deionizada a uma temperatura de 37ºC durante sete dias. No sétimo dia foi realizada a complementação do acabamento e polimento. Os grupos foram submetidos à ciclagem térmica com o tempo de imersão de 30 segundos em cada banho, a uma temperatura de 5 ºC e 55ºC, por 500 ciclos. Logo após, os corpos-de-prova foram submetidos à ciclagem mecânica, utilizando a máquina universal de ensaio EMIC programada para executar um carregamento e descarregamento axial de compressão na face lingual de cada dente restaurado. Inicialmente, foi aplicada uma carga ascendente de 1 a 10 kgf e descendente de 10 a 1 kgf durante 30 segundos, perfazendo um total de 100 ciclos para cada corpo-de-prova. Durante este ensaio, a porção coronária dos dentes ficou submersa em fucsina básica a 0,5 %. Após o término da ciclagem mecânica, os corpos-de-prova permaneceram por mais 24 horas mergulhados na mesma solução e, em seguida, foram lavados em água corrente por 12 horas. Cada dente foi seccionado em fatias transversais de aproximadamente 1,0 mm, sendo selecionada a fatia que apresentou maior grau de infiltração. Para avaliação da infiltração marginal foi utilizado um programa de análise de imagens, Image Tools, no qual foi medida a extensão da penetração do corante em milímetros. Os valores em milímetros da extensão de penetração do corante foram para os grupos 1 e 2; sendo 1,02 mm e 0,0 mm respectivamente. Aplicando o teste estatístico, verificou-se que houve diferença estatisticamente significante (p < 0,05) entre os valores de infiltração do grupo 1 (ausência de bisel) com os do grupo 2 (presença de bisel). Concluiu-se que a presença do bisel diminui significativamente a infiltração marginal nas restaurações de Classe IV, restaurações estas confeccionadas com o sistema restaurador adesivo e resina composta. / The purpose of this study was to evaluate the effect of bevel in the microleakage in restorations of composite resin, in cavities Class IV with bevel and without bevel around all the cavosurface margins, submitted to a thermal and mechanical cycled. The same dimensions was prepared, varying in the bevel presence or absence, thirty cavites of Class IV bovine teeth. Thereby, in group 1 the bevel was not done and in group 2 the bevel of 1 mm length was done around all the cavosurface margins. The cavities was restored with Single Bond / Z-250 (3 M). After restored, all restorations were finished with a scalpel. Afterwards, they were stored in deionize water at 37º C for seven days followed by the polishing procedures. All the groups were submitted to thermocycling 500 times between 5 ºC and 55 ºC, in a 30 seconds dwell time. For the mechanical cycled test, it was used the EMIC machine which was programmed to execute an axial load of 10 kgf, during 30 seconds in the lingual surface of the restorations. During the mechanical cycled test, the crown of the teeth remained submerse in a 0,5% basic fuchsin, and continued submerse until 24 hours had been completed. After that, the teeth were left 12 hours in the running water, followed by the section. Each tooth was parted in transversal sections with approximately 1,0 mm and the section with the higher amount of dye penetration was selected. It was used a program (Image Tool) to make possible an analysis of the images, to determined the dye penetration in milimeters. Through the results it is clearly that, there was a significant statistic difference (p < 0,05) between group 1 (absence of bevel) and group 2 (presence of bevel), which had 1,02 mm and 0,0 mm averages of dye penetration respectively. It was concluded that the procedure of bevel execution reduce expressively the microleakage around the margins of the restorations.
19

Avaliação clínica de restaurações de lesões cervicais não cariosas. / CLINICAL EVALUATION OF RESTORATIONS IN NON-CARIOUS CERVICAL LESIONS

Sérgio Lima Santiago 05 July 2002 (has links)
Avaliou-se o desempenho clínico de um sistema restaurador adesivo (Excite – Tetric Ceram/ Vivadent) e do cimento de ionômero de vidro modificado por resina (Vitremer/ 3M) na restauração de lesões cervicais não cariosas por meio do sistema de avaliação do USPHS modificado. Um total de setenta restaurações, trinta e cinco por material, foi realizado por um único operador em trinta pacientes voluntários com idades de 23 a 68 anos. Previamente à execução das restaurações, foi realizada uma profilaxia com pedra-pomes e água a fim de remover quaisquer resíduos. As lesões cervicais não foram submetidas a qualquer tipo de preparo cavitário, sendo restauradas sob isolamento absoluto e de acordo com as instruções do fabricante. Todas as restaurações foram avaliadas pelo método direto por dois examinadores nos intervalos de tempo estipulados: inicial (baseline), 6 meses, 1 ano e 2 anos usando os critérios de retenção, integridade marginal, descoloração marginal, manutenção da forma anatômica (desgaste), cárie secundária e sensibilidade pós-operatória. Ao final de dois anos, os resultados de restaurações clinicamente satisfatórios (escores Alfa e Bravo) obtidos para a resina composta e cimento de ionômero de vidro modificado por resina foram respectivamente: retenção (79%, 100%); integridade marginal (100%, 100%); descoloração marginal (100%, 100%); desgaste (96%, 100%); cárie secundária (100%, 100%) e sensibilidade pós-operatória (100%, 100%). Os resultados foram submetidos à análise estatística com o teste exato de Fisher ou o teste Quiquadrado de Pearson com nível de significância de 5% (p<0,05). As comparações intragrupos foram realizadas com o teste de McNemar com nível de significância de 5%. Com base na análise estatística dos resultados concluiu-se que houve diferença estatisticamente significante entre os materiais no critério retenção no período de 2 anos, sendo que nos demais critérios os dois materiais não apresentaram diferenças estatisticamente significante. / The purpose of this study was to assess the clinical performance of a monocomponent adhesive system (Excite/Tetric-Ceram Vivadent) and a resin-modified glass ionomer cement (Vitremer – 3M) to restore non-carious cervical lesions using a modified USPHS system. A total of 70 restorations (thirty-five per material) were performed by one operator in 30 patients 23-68 aged. Prior to restorations, teeth were pumiced with a prophy cup and restored following manufacturer’s instructions. All restorations were directly evaluated by two examiners at baseline, 6 months, 1 year and 2 years using the following: retention, marginal integrity, marginal discoloration, wear, recurrent caries postoperative and sensitivity. After two years. The ratings (Alpha and Bravo) of clinical satisfactory restorations were as follows (Tetric-Ceram/Vitremer): retention (79%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (96%/100%), recurrent caries (100%/100%) and postoperative sensitivity (100%/100%). Statistical analysis was completed with Fisher’s exact or Pearson Chi-square tests at a significance level of 5% (P<0.05). Intra-groups comparison was completed with McNemar’s test at a significance level of 5% (P<0.05). Results showed that all restorations of resinmodified glass ionomer cement were clinically satisfactory and there was significant difference between materials in retention criterion at 2 years of evaluation.
20

Desgaste abrasivo da resina composta Filtek Z250 (4 diferentes cores, fotopolimerizadas por 3 diferentes tempos), através do método do disco retificado / Abrasive wear of Filtek Z250 composite resin (4 different colors, light-cured by 3 different times) through the retified disc method.

Freitas, Márcia Furtado Antunes de 24 May 2007 (has links)
O objetivo neste trabalho foi avaliar a influência da variação do tempo de fotopolimerização para diferentes cores (I, B1, B3 e C4) de uma resina composta (FiltekTM Z250, da 3M ESPE), sobre a taxa de desgaste abrasivo através do método do disco retificado. Cada espécime de resina composta fotopolimerizada estava contido numa cavidade semicircular localizada na periferia de um disco constituído por polimetilmetacrilato (PMMA), denominado disco estático, sendo que a superfície curva da resina no disco sofria desgaste por um rebolo de porcelana, denominado tecnicamente de disco dinâmico, sob carga padronizada e velocidade controlada, criando no espécime uma cavidade de aspecto semicircular. O deslocamento vertical do disco estático, ao ser desgastado, era detectado por um palpador, o qual transferia estes dados a um computador e criava os arquivos de desgaste, em função do tempo. Os dados obtidos foram tratados estatisticamente. Pôde-se concluir que 1) a resistência à abrasão do PMMA foi a maior de todas e 2) a resina de cor C4, a mais resistente de todas. / The aim at this study was estimate the influence of light-curing time variation of different colors (I, B1, B3 and C4) of composite resin (FiltekTM Z250, 3M ESPE), upon abrasive wear through the retified disc method. The porcelain existent in the named dynamic disc promoted a wear of each resin specimen located in the polimethylmetacrylate (PMMA) static disc, under a standardized charge and with controlled velocity. Vertical displacement of static disc was detected by a sensor that send data to a computer where wear arquives were plotted in function of time. After data statistical analysis, it could be concluded that: 1) PMMA resistance was greater than anyone of resins and 2) C4 was more resistant than all the other colors.

Page generated in 0.0886 seconds