• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 17
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 57
  • 15
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

AVALIAÇÃO DENTOESQUELÉTICA E TEGUMENTAR DA RETRAÇÃO ANTERIOR EM DUAS FASES / Dentoskeletal and tegumentary assessment of the two- step retraction anterior

Marchiori, Geraldo Eugênio 04 October 2012 (has links)
Made available in DSpace on 2016-08-03T16:31:01Z (GMT). No. of bitstreams: 1 Geraldo Marchiori.pdf: 2085554 bytes, checksum: 64f4cf5b53c27500df06108f0655da54 (MD5) Previous issue date: 2012-10-04 / The present study consisted of evaluating dental, skeletal and tegumentary changes promoted by fixed orthodontic treatment with two-step retraction anterior, by means of lateral cephalograms. To this end, we selected 14 patients who required extraction of four premolars, all with Class I malocclusion. The anterior retraction was performed by the retraction of canine (prior to incisors bonding) and of incisors. Twelve patients did not use any device for anchoring. Lateral cephalograms were examined at the beginning and end of canine retraction and by the end of the fixed orthodontic treatment. Cephalograms were scanned to obtain cephalometric measurements using the software Radiocef® (RadiomemoryR- Belo Horizonte, Brazil). Data were submitted to analysis of variance and Tukey s test (p<0.05). Results indicated few skeletal changes, except for a slight retraction of the point A, and increase in mandibular length, in lower-anterior and total facial height, and slight mandibularcounterclockwiserotation due to the craniofacial growth. After canine retraction, there was a lingual inclination and retrusion of upper and lower incisors, which remained stable to the upper incisors at the end of the treatment. In the same period,the lower incisors retruded with a slope similar to the initial. Besides that, no significant loss of anchoring was detected. These dental changes resulted in retrusion of upper and lower lips after canine retraction, and the lower lip continued to retract by the end of the treatment. In conclusion, the treatment using two-step retraction anterior did not lead to a significant loss of anchoring, and reduced the facial convexity. / O objetivo do presente estudo consistiu em avaliar as alterações dentoesqueléticas e tegumentares promovidas pelo tratamento ortodôntico fixo com a retração anterior em duas fases, por meio de telerradiografias em norma lateral. Foram selecionados 14 pacientes com idade média de 14,6 anos que necessitavam de extrações dos quatro primeiros pré-molares, todos apresentando má oclusão de Classe I. A retração anterior foi realizada inicialmente pela retração dos caninos (previamente à colagem dos incisivos) e subsequentemente, pelos incisivos. Doze pacientes não utilizaram qualquer dispositivo para ancoragem e dois pacientes utilizaram como ancoragem o Arco Extra-Bucal (AEB) de uso noturno. Foram avaliadas as telerradiografias em norma lateral ao início, final da retração dos caninos e final de tratamento ortodôntico fixo. As telerradiografias foram escaneadas e mensuradas por meio do programa Radiocef® (RadiomemoryR- Belo Horizonte, Brasil). Os dados foram submetidos à Análise de Variância e teste de Tukey (p<0,05). Os resultados demonstraram poucas alterações esqueléticas, exceto por uma retrusão suave do ponto A e aumento do comprimento mandibular, da altura facial ântero-inferior e total e rotação suave anti-horária mandibular devido ao crescimento craniofacial. Após a retração dos caninos, houve uma inclinação para lingual e retrusão dos incisivos superiores e inferiores, que permaneceram estáveis para os incisivos superiores no período final de tratamento. Já os incisivos inferiores neste mesmo período, retruíram mais com uma inclinação semelhante àquela inicial. Além disso, não houve perda de ancoragem de forma estatisticamente significante. Estas alterações dentárias refletiram em retrusão dos lábios superior e inferior após a retração dos caninos, sendo que o lábio inferior continuou a retrair no período final de tratamento. Conclui-se que o tratamento com a retração em duas fases não representou perda de ancoragem estatisticamente significante, além de diminuir a convexidade facial.
32

Verificação da presença e abertura dos túbulos dentinários em pacientes portadores de recessão gengival com e sem hipersensibilidade dentinária por microscopia eletrônica de varredura

Vieira, Isabela Defilipo 20 June 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T11:30:14Z No. of bitstreams: 1 isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T11:51:38Z (GMT) No. of bitstreams: 1 isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5) / Made available in DSpace on 2016-07-13T11:51:38Z (GMT). No. of bitstreams: 1 isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5) Previous issue date: 2011-06-20 / O objetivo deste estudo foi verificar a presença e abertura dos túbulos dentinários em pacientes portadores de recessão gengival com e sem hipersensibilidade dentinária por microscopia eletrônica de varredura. Foram selecionados 11 pacientes onde foram avaliados os dentes sensíveis e não sensíveis, sendo constituídos dois grupos (n = 11), onde GE – experimental, onde foram considerados os dentes com hipersensibilidade e GC – controle, os dentes não sensíveis. Para a seleção dos dentes do GE, utilizou-se jato de ar por 3 segundos, sendo escolhido aquele em que o paciente relatou maior dor e para o GC utilizou-se o mesmo procedimento, sendo selecionado, aleatoriamente, um dos dentes em que o paciente não relatou dor. No exame periodontal foi mensurado o nível clínico de inserção no sítio vestibular, sendo o exame realizado por um único examinador devidamente calibrado. A partir das moldagens com silicona de adição foram obtidas réplicas negativas para análise em microscópio eletrônico de varredura para verificação da presença e características dos túbulos dentinários frente aos GE e GC. A medida de 2 mm do nível clínico de inserção foi prevalente com 63,60% (n = 7) para o GC, seguida de 3 mm com 45,50% (n = 5) para o GE. O nível clínico de inserção dos dentes do GC atingiu uma média de 2,45 ± 0,69 mm e do GE, 3,18 ± 1,16 mm. Quanto à presença e características ultramicroscópicas dos túbulos dentinários, a Prova dos Sinais demonstrou que a média de abertura dos túbulos dentinários do GE foi maior que do GC, 57,72 Rm e 34,82 Rm, respectivamente. Quanto ao número de túbulos dentinários, a situação se repetiu, porém com uma média de 1,45 para o GC e 3,18 para o GE (p = 0,044). Portanto, com base nos resultados obtidos neste estudo, foi possível concluir que pacientes portadores de recessão gengival com hipersensibilidade dentinária cervical apresentam túbulos dentinários em maior número e abertos ou semiabertos com diferentes diâmetros e que a técnica da réplica negativa analisada por microscopia eletrônica de varredura demonstrou ser uma importante ferramenta para visualização de túbulos dentinários. / The aim of this study was to determine the presence and opening of dentinal tubules, by scanning electron microscopy, in teeth of patients with gingival recession with and without dentin hypersensitivity. Eleven patients were selected, and sensitive and non-sensitive teeth were evaluated and divided into two groups (n = 11), where GE – experimental, which were considered hypersensitive teeth and GC – control, non-sensitive teeth. For the selection of the teeth of GE, air blast was used for 3 seconds, and was chose the one which the patient reported increased pain and the GC used the same procedure, selecting randomly, a tooth where the patient reported no pain. Periodontal examination measured the clinical attachment level at buccal side, and the examination was performed by a single examiner calibrated. From the impressions with vinyl polysiloxane, negative replica was obtained for analysis in scanning electron microscope to detect the presence and characteristics of dentinal tubules compared to the GE and GC. The measurement of 2 mm of clinical attachment level was prevalent in 63.60% (n = 7) for the GC, followed by 3 mm with 45.50% (n = 5) for GE. The clinical attachment level of the teeth of GC averaged 2.45 ± 0.69 mm and GE, 3.18 ± 1.16 mm. Regarding the presence and ultramicroscopic characteristics of dentinal tubules, the Statistical Test Signals showed that the average opening of dentinal tubules of GE was higher than the GC, 57.72 3m and 34.82 3m, respectively. Regarding the number of dentinal tubules, the situation was repeated, but with an average of 1.45 for GC and 3.18 for GE (p = 0.044). Therefore, based on the results of this study, it can be concluded that patients with gingival recession and dentin hypersensitivity present dentinal tubules in greater numbers and open or half-open with different diameters and that the technique of negative replica analyzed by scanning electron microscopy is an important tool for visualization of dentinal tubules.
33

In vitro comparison of force decay between three orthodontic sliding retraction methods

Steiger, Pamela 01 January 2014 (has links)
Objective: The purpose of this in vitro study was to determine if there is a difference in force decay between three sliding retraction methods under a standardized force delivery system (200 gm at 25 mm stretch) at 2, 4, 6, and 8 weeks. Background: In order to achieve proper esthetics, occlusion and stability, orthodontic treatment may require extractions. Elastomeric chains, Nickel Titanium (NiTi) coils, and active ligatures are commonly used to close these extraction spaces. Methods: Twenty samples of each retraction method (elastomeric chains, NiTi Coils and active ligatures) were evaluated under standardized conditions (200 gm at 25 mm). The force of each retraction method was measured at 0, 2, 4, 6, and 8 weeks on a customized force gauge test stand (Shimpo FGV-1XY force gauge; Shimpo Instruments, Itasca, IL). Ten control samples were evaluated at 0 weeks and left un-stretched until the final measurement at 8 weeks. All samples were stored in a bath of Fusayama/Meyer artificial saliva (Pickering Laboratories, Mountain View, California) at 37°C in order to simulate the oral cavity. Results: At 2 weeks, the NiTi coils maintained their force while both the elastomeric chains and active ligatures experienced a statistically significant decrease in force over time. At 4, 6, and 8 weeks, the force of the elastomeric chains and active ligatures continued to decay and demonstrated a statistically significant decrease in force as compared to the NiTi coils and each other. At 8 weeks, the NiTi coils, elastomeric chains and active ligatures maintained 94.0%, 66.8% and 50.9%, respectively. This signifies a hierarchy of force decay with NiTi coils maintaining the largest amount of force, followed by the elastomeric chains and then the active ligatures. Conclusion: There is a significant difference in the amount of force decay of the three retraction methods over time under a standard initial force delivery of 200 gm over a 25 mm stretch. NiTi coils provide the light and constant force desired for efficient and biologically compatible tooth movement. The elastomeric chains maintained a larger amount of force than expected and have proven to achieve comparable tooth movement to NiTi coils in clinical studies. Active ligatures do not appear to be an effective means of force delivery. A force gauge is recommended to evaluate all forces placed clinically.
34

Designing bioinspired materials with tunable structures and properties from natural and synthetic polymers

Varadarajan, Anandavalli 08 August 2023 (has links) (PDF)
Biological systems are composed of complex materials which are responsible for performing various functions, such as providing structural support, mobility, functional adaptation to the environment, damage repair, and self-healing. These complex materials display excellent mechanical properties and can rapidly adapt to external stimuli. Thus, nature inspires in terms of source materials, functions, and designs to develop new-generation structural and functional materials. Polymers (natural or synthetic) are excellent sources of developing materials to mimic the functions of soft segments in biological systems. This dissertation focuses on synthesizing and characterizing two different materials with tunable structures and properties: complexes from natural polysaccharides or polyelectrolytes and bioinspired hydrogels from synthetic polymers. Oppositely charged polyelectrolytes can form polyelectrolyte complexes (PECs) due to the electrostatic interactions. The structure and properties of PECs can be tuned by varying the salt concentration, as the addition of salt can facilitate associative phase separation. PECs were prepared from two biopolymers, positively charged chitosan and negatively charged alginate. Rheological experiments for the complexes displayed a tunable shear modulus with changing salt concentrations. The microstructural study conducted using small-angle X-ray scattering provided insights regarding the length scales of these complexes, and the results follow the observed rheological and phase behavior. Elastic biopolymers such as resilin display remarkable mechanical properties, including high stretchability and resilience, which many species exploit in nature for mechanical energy storage to facilitate their movement. Such properties of resilin have been attributed to the balanced combination of hydrophilic and hydrophobic segments present in the chain. In this work, we synthesized hydrogels with hydrophilic and hydrophobic components to mimic the properties of resilin. With this system, we determined the tensile, retraction (ability to revert to the original state after stretching), and swelling properties when (i) the concentration of the hydrophobic polymer was varied and (ii) additional hydrophobic components were included. The stretchability, stiffness, and strength of the gels varied as the compositions were altered. The fundamental understanding of the structure-property-function relationship for materials presented in this work provides insights into engineering materials for applications such as tissue engineering, drug delivery, wound healing, artificial muscles, soft robotics, and power amplification.
35

An Investigation of the Role of Macrophages in Spinal Cord Injury and Repair

Horn, Kevin Paul January 2010 (has links)
No description available.
36

Genetic Engineering of Functional Large Amyloid Fibers

Roth, David Eugene 29 January 2016 (has links)
"Template" and "adder" proteins can be genetically encoded to produce large amyloid fibers when mixed together. Escherichia coli is used to clone a "template" protein, Gd20, which will cooperatively self-assemble with two "adder" proteins, P7Q and P7S, to yield two different large amyloid fibers. Atomic force microscopy (AFM) is used to image the fibers and AFM tip approach/retraction force is used to quantify molecular packing in the fibers. Glutamine (Q)-containing P7Q and serine (S)-containing P7S both have the same hydrophobic core, charge, and hydrogen bonding potential. However, P7Q is highly alpha-helical while P7S contains a beta-sheet core. After 72 hours, the Gd20:P7Q template:adder protein mixture produces tightly packed ~0.3 μm high and ~1.9 μm wide fibers that exhibit a low retraction force of ~44 nN after indentation. The Gd20:P7S mixture produces larger ~1.1 μm high and ~9.7 μm wide fibers exhibiting a much higher retraction force of ~503 nN showing they are much less molecularly packed. These results indicate that the adder protein alpha-helical character is important for self-assembly and molecular packing inside of the large amyloid fiber. The experimental results show that large amyloid fibers with predictable size and mechanical properties can be anticipated and encoded at the genetic level. / Master of Science
37

AVALIAÇÃO DE FORÇAS LIBERADAS POR ALÇAS EM FORMA DE GOTA UTILIZADAS EM MECÂNICA ORTODÔNTICA PARA FECHAMENTO DE ESPAÇOS / EVALUATION OF FORCES DELIVERED BY TEARDROP LOOPS USED IN ORTHODONTIC MECHANICS FOR CLOSING SPACES

D'ornellas, Mauro Cordeiro 22 January 2010 (has links)
The purpose of this research was to investigate the influence of height, crosssection and metal alloy in the mechanical act of teardrop loops used in incisors retraction and in en masse retraction of incisors and canines, aiming analyze the mechanical behavior of these loops in relation to optimum forces presented in the literature. Two hundred and forty loops were submitted to a tensile load on the testing machine considered heights of 6mm, 8mm and 10mm; cross-sections of 0.018in.x 0.025in and 0.019in.x 0.025in and wire materials of stainless steel and beta-titanium alloys. It was obtained magnitudes of horizontal force (N) and load-deflection (N/mm) for each loop across activations of 0.5mm, 1mm, 1.5mm, 2mm and 2.5mm. The results showed that height (p<0.01), cross-section and metal alloy (p<0.05) were considered significant factors with reference to horizontal force and load-deflection. There was no influence of one factor but a combination of these trying to achieve very light forces. This study suggest that is necessary a large orthodontic biomechanics knowledge with respect to loops design used in incisors retraction and in en masse retraction of incisors and canines, selecting adequate height, crosssection and metal alloy. / O objetivo desta pesquisa foi investigar os efeitos da altura, secção transversal e tipo de liga no desempenho mecânico de alças confeccionadas em forma de gota, indicadas para a retração de incisivos e para a retração em massa de incisivos e caninos, buscando avaliar o comportamento das mesmas em relação às magnitudes de força ótima existentes na literatura. Foram submetidas a um ensaio mecânico 240 alças, considerando as alturas de 6mm, 8mm e 10mm; as seções transversais de 0.018 x 0.025 e de 0.019 x 0.025 e as ligas de aço inoxidável e beta-titânio (TMA). Foram obtidos valores de força horizontal (N) e carga-deflexão (N/mm) para cada alça mediante ativações de 0.5mm, 1mm, 1.5mm, 2mm e 2.5mm. Os resultados mostraram que a altura (p<0.01), a secção transversal e a liga (p<0.05) foram consideradas fatores significativos na força horizontal e cargadeflexão gerada. Não houve influência de um fator sobre os demais, mas sim, uma combinação destes, buscando atingir forças muito leves. Este estudo sugere que é necessário amplo conhecimento da biomecânica ortodôntica na confecção de alças direcionadas para a retração dos dentes anteriores, selecionando adequadamente a altura, a secção transversal e a liga.
38

Estudo comparativo da ação biomecânica de alças ortodônticas confeccionadas em fios retangulares\" / Comparative study of biomechanical action of orthodontic loops made with rectangular wires

Cecilio, Eliane 10 November 2006 (has links)
No tratamento das maloclusões muitas vezes se impõe a necessidade de extrações dentárias para cumprir as metas do tratamento ortodôntico em busca da oclusão normal. Um dos recursos para o fechamento de espaços após exodontias é a utilização de arcos de retração com alças. Atualmente existe, no mercado, uma grande disponibilidade de arcos pré-fabricados, fornecidos por diversos fabricantes, que apresentam variações na forma e número de alças, espessura dos fios e ligas metálicas diferentes. O conhecimento das propriedades mecânicas e das forças liberadas por estes arcos é de extrema importância para que se obtenha uma resposta biológica adequada durante a movimentação dentária. O presente estudo procurou avaliar, experimentalmente, as forças liberadas por alguns tipos mais utilizados de arcos com alças produzidos com fios de secção retangular com variações de geometria (espessura, número e forma das alças), liga metálica e fabricante, impondo-lhes diferentes ativações. Buscou-se ainda determinar a quantidade de ativação onde ocorre o limite de proporcionalidade e, finalmente, fazer comparações entre os arcos com o intuito de fornecer ao ortodontista subsídios para a escolha do arco adequado. Para tal foram utilizados 19 tipos diferentes de arcos submetidos a testes de tração. Foram registradas as forças continuamente até uma deformação das alças de 4 mm. As comparações foram realizadas por meio de testes estatísticos isolando-se apenas uma característica de variação permitindo uma melhor compreensão do fator preponderante na alteração da força. Os resultados revelaram variações importantes nas forças a cada 0,5 mm de ativação, sendo de forma geral, ativações de 0,5 e 1,0 mm as que liberam forças mais adequadas. Os limites de proporcionalidade ocorreram na sua maioria acima de 1,5 mm de ativação até 2,5 mm, podendo em arcos mais flexíveis ocorrer acima de 4,0 mm. As comparações estatísticas demonstraram diferenças significativas entre todos os grupos avaliados, revelando que todas as variações (geometria, espessura, material e fabricante) exercem influência sobre a força gerada, sendo que a liga metálica parece ser preponderante. / In malocclusion treatments, dental extractions become necessary, in some cases, in order to achieve orthodontic goals of normal occlusion. One of the devices employed to close spaces after dental extraction is the use of retraction arches with loops. Nowadays, there is a wide range of pre-manufactured arches in the market, which present variations in shape, number of loops, thickness of the wire and metallic alloys. It is extremely important to understand mechanical properties as well as the forces delivered by these arches in order to achieve proper biological response during tooth movement. The present study tried to evaluate, experimentally, forces delivered by some of the most frequently employed arches made of rectangular wires with different geometrical characteristics (thickness, number and shape of loops), metallic alloys and made by different manufacturers, when submitted to different levels of activation. It was tried to determine the activation level at proportional limit and compare these values for different arches, in order to provide the orthodontists with accurate data which may help them to choose the proper arches. Nineteen different types of arches were submitted to tension tests. Forces were continuously measured up to 4 mm level of loop deformation. Statistical tests were employed to make comparisons, with only one type of variation for each test, which allowed a better comprehension of the main factor in force change. Results revealed important variations in forces at 0.5 mm intervals, and generally, 0.5 mm and 1.0 mm levels of activation delivered the most proper forces. Proportional limit occurred, mostly, over 1.5 mm and up to 2.5 mm levels of activation, except for more flexible arches, when it occurred above 4.0 mm. Statistical comparisons showed significant differences between all groups studied, demonstrating that all variations (geometry, thickness, material and manufacturer) can influence the delivered force. In spite of this, metallic alloys seemed to be the most important factor determining force deliverance variation.
39

Estudo do agregado graúdo reciclado de concreto como agente de cura interna em concreto com cinza de casa de arroz

Jordani, Bárbara 31 March 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-06-15T14:11:52Z No. of bitstreams: 1 BÁRBARA JORDANI_.pdf: 2132585 bytes, checksum: 322ec6d990fc948ff3060abffa46014a (MD5) / Made available in DSpace on 2016-06-15T14:11:52Z (GMT). No. of bitstreams: 1 BÁRBARA JORDANI_.pdf: 2132585 bytes, checksum: 322ec6d990fc948ff3060abffa46014a (MD5) Previous issue date: 2016-03-31 / FAPERGS - Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPQ - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nos últimos anos o setor da construção civil está buscando alternativas para substituir as matérias primas utilizadas no processo de produção do concreto, visando preservar o meio ambiente reduzindo extrações da natureza. Diante disso, surge a reciclagem de materiais, que vem ganhando cada vez mais espaço dentro da atividade da construção civil. Uma das alternativas é a utilização de agregados reciclados de concreto (ARC), que podem ser empregados como substituição ao agregado natural. Outra possibilidade é o uso de pozolanas provenientes de resíduos, e dentre as diferentes opções a cinza de casca de arroz se destaca. A cinza de casca de arroz ainda não é largamente utilizada no ocidente, porém vem sendo explorada, sendo um resíduo do setor agropecuário. Após o processo de queima da casca do arroz, surge a cinza que possui grande concentração de sílica. O uso destas pozolanas contribui para diminuir o consumo de cimento. Além disto, o emprego de agregados reciclados pré-saturados pode atuar como um agente de cura interna de concretos, o que, em caso de concretos com pozolanas, pode ser um aspecto positivo para obter-se uma boa hidratação da pasta aglomerante. Este trabalho propõe investigar o efeito do emprego de agregados graúdos reciclados de resíduo de concreto (AGRC) como agente de cura interna em concretos produzidos com pozolana, frente a aspectos vinculados à durabilidade e ao comportamento mecânico. Avaliou-se a substituição do agregado graúdo natural (AN) por (AGRC) em teor determinado pelo Método de Dosagem para Cura Interna, seco e úmido, associado com a substituição de cimento por cinza de casca de arroz em teor de 20%, em dois ambientes de cura (U.R 60% e 100%). Para o estudo foi utilizado três relações a/agl (0,31; 0,42; e 0,53). Os resultados apontaram um efeito positivo do emprego da CCA em concretos fabricados com AGRC. A substituição de cimento por CCA em média pode aumentar a resistência à compressão. Os concretos fabricados com relação a/agl 0,31, para todos os concretos ensaiados, retornaram resistências na faixa de 35-45 MPa. Também foi possível notar retrações significativas até os 28 dias. Já para cura interna cabe ressaltar que o AGRC empregado saturado não apresenta comportamento de agente de cura interna, principalmente no ambiente crítico de ambiente com umidade relativa na ordem de 60%, considerada baixa. / During the last years, the construction sector has been looking for alternatives to replace the raw materials used for concrete production, in order to reduce environmenal impact. The waste recycling as raw material for civil construction can be one of solutions to this problem. One example of this kind of solution is to use the recycled concrete aggregate, which can be used as alternative for the natural aggregate. Another possibility is to use some waste as pozzolanic material, as the rice husk ash. After the burning of the rice hull, it becomes the ash, which has a large concentration of silica. The use of these pozzolans can contribute to reduce the consumption of cement. Furthermore, the usage of pre-saturated recycled aggregate can act as an internal concrete curing agent, which in the case of concretes with pozzolans can be a good way to obtain a better hydration of the binder paste. This study proposes to investigate the effect of the usage of concrete recycled coarse aggregate (RCCA) as an internal curing agent in concrete produced with pozzolan, in order to evaluate the durability and mechanical behaviour. It was evaluated the replacement of natural coarse aggregate (AN) by RCCA. The content of RCCA is related to the binder consumption and it was employed dry and wet. The cement replacement by rice husk ash was done at 20% and it was used three water to binder (w/t) relationships (0.31, 0.42, and 0.53). The curing process was developed in two cure environments (U.R 60% and 100%).The results indicated that the CCA produces positive effect on concrete made with AGRC. The concrete made with respect to w/b 0.31 for all tested concretes returned resistances in the range of 35-45 MPa. The effect of RCCA as internal curing agent is significant when the concrete is cured in a humid environment only for compressive strength. In dry environment, it does not work as internal curing agent. It was also noted significant retractions up to 28 days. As for domestic demand it is noteworthy that the saturated employee AGRC has no internal curing agent behaviour, especially in the critical environment with relative humidity of around 60%, considered low.
40

A influência do polímero superabsorvente nas propriedades de concreto convencional / The Influence of superabsorbent polymer in conventional concrete properties

João, Fernanda Aparecida 24 September 2016 (has links)
Made available in DSpace on 2016-12-08T17:19:27Z (GMT). No. of bitstreams: 1 FERNANDA APARECIDA JOAO.pdf: 13614051 bytes, checksum: 7d071a80e981abbf95a9074b2c139bba (MD5) Previous issue date: 2016-09-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Cracks in concrete are a problem caused by the shrinkage of the mixture. This retraction can be plastic, autogenous, by drying or carbonation may occur and more than one type of retraction. One of the retraction methods of warfare is by curing of the concrete, the usual method of healing with external wetting, causes waste of water. Thus a new curing method has been studied via light aggregates or saturated superabsorbent polymer, inserted into the concrete mass, known as internal cure. The research in this paper aims to verify the influence of superabsorbent polymer as an internal curing agent to combat the decline in conventional concrete. The materials used for the development of this research were cement, natural sand, coarse aggregate (gravel), water and superabsorbent polymer of sodium polyacrylate. Initially it was performed characterization tests of the raw materials used, then made the specimens and then the characterization of concrete specimens with and without superabsorbent polymer. Properties in the fresh state (consistency) and hardened (compressive strength and shrinkage) were evaluated. The samples were subjected to physical-chemical and structural micro, through techniques of X-ray diffraction, infrared spectroscopy Fourier transform (FTIR), stereoscopic images and scanning electron microscopy. Six mixtures were prepared, a reference superabsorbent polymer with five levels (PSA). The PSA was inserted into the concrete as addition and replacement of mixing water with different grades and sizes. The tests showed that the superabsorbent polymer has affected the workability of concrete mixtures, the compressive strength after 28 and 60 days of curing and shrinkage. The polymer did not change the phases of the concrete, and microstructure was possible to see that the PSA was not crowded. The test results in some mixtures showed improved mechanical properties over the internal cure with superabsorbent polymer. / As fissuras no concreto são um problema ocasionado pela retração da mistura. Esta retração pode ser plástica, autógena, por secagem ou carbonatação, e pode ocorrer de forma combinada. Um dos métodos de combate à retração é realizado durante a cura do concreto. O método usual de cura com molhagem externa ocasiona desperdício de água. Desta forma, um novo método conhecido como cura interna vem sendo estudado, por meio da utilização de agregados leves ou polímeros superabsorventes saturados, inseridos na massa de concreto. A pesquisa realizada no presente trabalho tem como objetivo verificar a influência do polímero superabsorvente como agente de cura interna para combater a retração em concreto convencional. Os materiais utilizados para o desenvolvimento desta pesquisa foram: cimento CP-II 32 Z, agregado miúdo (areia natural média), agregado graúdo (brita no 0 e no 1), água e polímero superabsorvente de poliacrilato de sódio. Inicialmente, foram realizados ensaios normalizados de caracterização das matérias primas utilizadas para produzir os corpos de prova. Em seguida, realizou-se a caracterização dos corpos de prova de concreto com e sem polímero superabsorvente. Posteriormente, foram avaliadas as propriedades no estado fresco (consistência) e no endurecido (resistência à compressão e retração). Os corpos de prova foram submetidos à caracterização físico-química e micro estrutural, por meio de técnicas de difratometria de raios X, espectroscopia de infravermelho com transformada de Fourier (FTIR), imagens de estereoscópio e microscopia eletrônica de varredura. Foram produzidas seis misturas, uma de referência e cinco com teores diferentes de polímero superabsorvente (PSA). O PSA foi inserido no concreto tanto como adição quanto como substituição da água de amassamento, com diferentes teores e tamanhos. Os ensaios mostraram que o polímero superabsorvente afetou a trabalhabilidade das misturas de concreto, a resistência à compressão aos 28 e aos 60 dias de cura e a retração. O polímero não interferiu no processo de hidratação do concreto, além disso, foi possível visualizar que o PSA não ficou aglomerado na microestrutura. Os resultados dos ensaios em algumas misturas mostraram melhora nas propriedades mecânicas por meio da cura interna com o polímero superabsorvente estudado.

Page generated in 0.0649 seconds