• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudos de marcação do etidronato com sup(188)Re proveniente de diferentes gerações de sup(188)W/sup(188)Re

MARCZEWSKI, BARBARA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:22Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
2

Desenvolvimento da tecnologia de preparo de geradores de sup(188)W-sup(188)Re

OLIVEIRA, ALEXANDRE de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:34Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:34Z (GMT). No. of bitstreams: 1 09995.pdf: 3401015 bytes, checksum: aced83202c3f7ecb0a8933fda0aed0aa (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
3

Estudo comparativo da marcacao do anticorpo anti-CD20 com sup(188)Re / Comparative studies of antibody anti-CD20 labeled with 188Re

DIAS, CARLA R. de B.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:35Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
4

Estudos de marcação do etidronato com sup(188)Re proveniente de diferentes gerações de sup(188)W/sup(188)Re

MARCZEWSKI, BARBARA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:22Z (GMT). No. of bitstreams: 0 / O interesse pelo 188Re para aplicações terapêuticas na medicina nuclear é devido à meia-vida de 16,9 horas, emissão de partículas βֿ com energia máxima de 2,12 MeV e raios-γ de 155 keV adequados para a aquisição de imagens. O estudo apresenta a radiomarcação do HEDP (etidronato) com o 188Re eluído de geradores de 188W/188Re a base de Al2O3 e tipo-gel 188WZr. A dependência do rendimento do 188Re-HEDP na concentração do agente redutor, pH, tempo de reação, temperatura e adição de carregador Re2O7 foram avaliados. A partir das condições ótimas de marcação os rendimentos do 188Re-HEDP foram ≥ 98% tanto para os kits líquidos como liofilizados. A formulação padrão que representou esses resultados contém: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ácido ascórbico e adição de 20 μg de Re2O7. As reações foram conduzidas sob aquecimento de 100 °C por 30 minutos, seguidos de 60 minutos de incubação. Outro aspecto importante do trabalho foi o controle de qualidade radioquímico, comparando os resultados de CP, CCD e cromatografia iônica, além dos experimentos com a CLAE. A distribuição biológica realizada comprovou a captação pelo esqueleto e a estabilidade in vivo dos complexos de 188Re-HEDP. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
5

Desenvolvimento da tecnologia de preparo de geradores de sup(188)W-sup(188)Re

OLIVEIRA, ALEXANDRE de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:34Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:34Z (GMT). No. of bitstreams: 1 09995.pdf: 3401015 bytes, checksum: aced83202c3f7ecb0a8933fda0aed0aa (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
6

Estudo comparativo da marcacao do anticorpo anti-CD20 com sup(188)Re / Comparative studies of antibody anti-CD20 labeled with 188Re

DIAS, CARLA R. de B.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:35Z (GMT). No. of bitstreams: 0 / A Medicina Nuclear é uma modalidade de particular importância em oncologia e a investigação de novos radiofármacos direcionados a tumores, seja para diagnóstico e/ou terapia, é uma área de interesse para os pesquisadores. Rituximab (RTX) é um anticorpo monoclonal (AcM) quimérico (IgG 1) que se liga especificamente ao antígeno CD20 com alta afinidade e tem sido usado com sucesso para tratar Linfoma Não-Hodgkin (LNH) de células-B. O antígeno CD20 é expresso sobre mais de 90% dos LNH de células-B. Tecnécio-99m (99mTc) e rênio-188 (188Re) representam um atrativo par de radionuclídeos para uso médico devido as favoráveis propriedades de decaimento para diagnóstico (99mTc: T1/2 = 6 h, radiação γ = 140 keV) e terapia (188Re: T1/2 = 17 h, radiação máxima = 2,12 MeV) e por causa de sua disponibilidade graças aos sistemas de geradores correspondentes 99Mo/99mTc e 188W/188Re. Estes dois radionuclídeos podem ser conjugados aos anticorpos usando métodos químicos similares. O objetivo geral deste trabalho foi estudar a marcação do AcM anti-CD20 (Rituximab) com o radioisótopo 188Re usando duas técnicas: método direto de marcação [188Re(V)] e método de marcação via núcleo carbonila [188Re(I)]. Além do controle de qualidade, o anticorpo radiomarcado foi submetido a estudo biológico in vivo, in vitro e ex vivo. Para a marcação direta, o RTX foi reduzido pela incubação com o agente redutor 2-mercaptoetanol para a geração de grupos sulfidrilas (-SH) e posteriormente marcado com 188Re(V), fazendo-se um amplo estudo de variáveis para se chegar a uma formulação otimizada. Para a marcação usando o núcleo carbonila foram usados os radioisótopos 99mTc e 188Re e dois procedimentos de radiomarcação: (1) RTX nativo marcado com 99mTc(I) e (2) RTX reduzido (RTXred) marcado com 99mTc(I)/188Re(I). Também foi feito um estudo de variáveis para se chegar a formulação otimizada. O método de controle de qualidade para avaliação da pureza radioquímica mostrou um bom rendimento de marcação (93%) para o método direto. Na marcação com o núcleo carbonila, os resultados mostraram que os grupos -SH do anticorpo reduzido são uma possível via de ligação. A formação do composto 99mTc(I)-RTXred foi mais rápida do que 188Re(I)- RTXred, que por sua vez mostrou melhor estabilidade em plasma humano e nenhuma transquelação no desafio a histidina ou cisteína. Os dois compostos mostraram boa afinidade de ligação e uma biodistribuição em camundongos portadores de tumor coerente com a biodistribuição normal do anticorpo e razoável captação no tumor provando a eficiência do método de marcação e potencial uso clínico. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
7

Estudos de marcação do etidronato com 188Re proveniente de diferentes geradores de 188W/ 188Re / Studies of HEDP labelled with 188Re from different generators of 188W / 188Re.

Marczewski, Barbara Szot 21 December 2006 (has links)
O interesse pelo 188Re para aplicações terapêuticas na medicina nuclear é devido à meia-vida de 16,9 horas, emissão de partículas βֿ com energia máxima de 2,12 MeV e raios-γ de 155 keV adequados para a aquisição de imagens. O estudo apresenta a radiomarcação do HEDP (etidronato) com o 188Re eluído de geradores de 188W/188Re a base de Al2O3 e tipo-gel 188WZr. A dependência do rendimento do 188Re-HEDP na concentração do agente redutor, pH, tempo de reação, temperatura e adição de carregador Re2O7 foram avaliados. A partir das condições ótimas de marcação os rendimentos do 188Re-HEDP foram ≥ 98% tanto para os kits líquidos como liofilizados. A formulação padrão que representou esses resultados contém: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ácido ascórbico e adição de 20 μg de Re2O7. As reações foram conduzidas sob aquecimento de 100 °C por 30 minutos, seguidos de 60 minutos de incubação. Outro aspecto importante do trabalho foi o controle de qualidade radioquímico, comparando os resultados de CP, CCD e cromatografia iônica, além dos experimentos com a CLAE. A distribuição biológica realizada comprovou a captação pelo esqueleto e a estabilidade in vivo dos complexos de 188Re-HEDP. / The widespread interest in 188Re for therapeutic applications, is due to its attractive 16,9 hours half-life, emission of a βֿ particle with maximum energy of 2.12 MeV and gama-ray of 155 keV suitable for imaging. This work presents the radiollabeling of HEDP (etidronate) with 188Re eluted from alumina-based 188W/188Re generators and tungstate-based 188W/188Re gel generators. Dependence of the yield of the 188Re-HEDP on the concentration of the reduction agent, pH, reaction time, temperature and addition of carrier Re2O7 were evaluated. The radiollabeling of 188Re-HEDP procedure using the optimum conditions resulted a yield ≥ 98% for liquid and lyophilized kits. This basic formulation contains: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ascorbic acid and addition of 20 μg of Re2O7. The reactions were carried out with heating in boiling water for 30 minutes followed by 60 minutes of incubation. Another important aspect of this work was the radiochemical quality control compairing the results of PC, TLC and ion chromatography, along with the experiments with HPLC. The biological distribution proved the adequate bone uptake and in vivo stability of 188Re-HEDP complexes.
8

Comparação da marcação de diversos fosfonatos: MDP, EDTMP e clodronato com 188Re / Comparison of labeling various phosphonates: MDP, EDTMP and clodronate with 188Re

Barbezan, Angelica Bueno 26 October 2012 (has links)
A grande aplicação dos radiofármacos está em medicina nuclear diagnóstica representando 95% dos procedimentos realizados, porém, nos últimos anos, tem crescido consideravelmente a sua aplicação em procedimentos terapêuticos. Os radionuclídeos que emitem particulas ionizantes (α, β e elétrons Auger) são indicados para tratamento de tumores. Tumores malignos são responsáveis por aproximadamente 12% dos óbitos e representam a terceira causa de mortalidade no Brasil. O 188Re é um dos mais atrativos radioisótopos para uma variedade de aplicações terapêuticas em medicina nuclear, oncologia e intervenções cardiológicas, é totalmente favorável e conveniente pelo fato de que ele é livre de carregador e pode ser obtido de forma econômica na forma de um gerador de 188W/188Re, além de possuir uma meia-vida fisica de 16,9 horas e 100% de emissão de radiação β-. A partir da década de 2000 vêm sendo realizadas diversas investigações envolvendo marcações de moléculas com 188Re. Os tumores metastáticos são a forma mais comum de malignidade esquelética. Em casos metastáticos os principais objetivos do tratamento são a prevenção de fraturas patológicas e promover a sobrevida com o máximo de preservação de função permitindo que o paciente mantenha o máximo possível de mobilidade e controle da dor. O objetivo deste trabalho foi realizar a comparação das marcações de diversos fosfonatos (Metileno disfofonato de Sódio MDP, Ácido Etilenodiaminotetrametilenofosfônico EDTMP, e do diclorometilenobifosfonato de sódio - Clodronato) com 188Re para terapia de metastáses ósseas. Fosfonatos são inibidores da reabsorção óssea osteoclástica e são efetivos neste tratamento. As marcações do MDP, EDTMP e Clodronato com 188Re foram otimizadas utilizando como agente redutor o cloreto estanoso (SnCl2 2H2O) e como agente estabilizante o ácido ascórbico. As variáveis estudadas foram massa do ligante, massa do SnCl2.2H2O, massa do ácido ascórbico, tempo, pH e temperatura da reação. Os resultados mostraram que se obteve um excelente rendimento de marcação de 98% para o 188Re-MDP, de 83% para o 188Re-EDTMP e 85% para o 188Re-Clodronato. / The wide application of radiopharmaceuticals in nuclear medicine, representing 95% of procedures performed is in diagnosis, but in recent years, its application in therapeutic procedures has grown considerably. The radionuclides that emit ionizing particles (α, β, and Auger electrons) are indicated for the treatment of tumors. Malignant tumors account for approximately 12% of deaths and represent the third cause of mortality in Brazil. 188Re is one of the most attractive radioisotopes for a variety of therapeutic applications in nuclear medicine, oncology and cardiology interventions, is fully favorable and convenient because it is carrier free and can be obtained inexpensively in the form of a generator of 188W/188Re, and has a physical half-life of 16.9 hours and 100% of β-radiation emission. From the 2000s several investigations have been conducted involving molecules labeled with 188Re. Metastatic tumors are the most common form of malignancy in the skeleton. In metastatic cases the main goals of treatment are the prevention of pathological fractures and the promotion of survival with maximum preservation of function allowing the patient to maintain the greatest possible mobility and pain control. The objective of this study was to compare the labeling of various phosphonates (Sodium methylene diphosphonate - MDP, Ethylenediaminetetramethylene phosphonic acid - EDTMP, and sodium dichloromethylenediphosphonate - clodronate) with 188Re for bone metastases therapy. Phosphonates are inhibitors of osteoclastic bone resorption and are effective in treatment. The labeling of MDP, EDTMP and Clodronate with 188Re was optimized using stannous chloride (SnCl2·2H2O) as reducing agent, and ascorbic acid as stabilizing agent. The variables studied were the ligand mass, SnCl2.2H2O mass, mass of ascorbic acid, time, pH and temperature of the reaction. The results showed an excellent labeling yield of 98% for 188Re-MDP, 83% for 188Re-EDTMP and 85% for 188Re-Clodronate.
9

Comparação da marcação de diversos fosfonatos: MDP, EDTMP e clodronato com 188Re / Comparison of labeling various phosphonates: MDP, EDTMP and clodronate with 188Re

Angelica Bueno Barbezan 26 October 2012 (has links)
A grande aplicação dos radiofármacos está em medicina nuclear diagnóstica representando 95% dos procedimentos realizados, porém, nos últimos anos, tem crescido consideravelmente a sua aplicação em procedimentos terapêuticos. Os radionuclídeos que emitem particulas ionizantes (α, β e elétrons Auger) são indicados para tratamento de tumores. Tumores malignos são responsáveis por aproximadamente 12% dos óbitos e representam a terceira causa de mortalidade no Brasil. O 188Re é um dos mais atrativos radioisótopos para uma variedade de aplicações terapêuticas em medicina nuclear, oncologia e intervenções cardiológicas, é totalmente favorável e conveniente pelo fato de que ele é livre de carregador e pode ser obtido de forma econômica na forma de um gerador de 188W/188Re, além de possuir uma meia-vida fisica de 16,9 horas e 100% de emissão de radiação β-. A partir da década de 2000 vêm sendo realizadas diversas investigações envolvendo marcações de moléculas com 188Re. Os tumores metastáticos são a forma mais comum de malignidade esquelética. Em casos metastáticos os principais objetivos do tratamento são a prevenção de fraturas patológicas e promover a sobrevida com o máximo de preservação de função permitindo que o paciente mantenha o máximo possível de mobilidade e controle da dor. O objetivo deste trabalho foi realizar a comparação das marcações de diversos fosfonatos (Metileno disfofonato de Sódio MDP, Ácido Etilenodiaminotetrametilenofosfônico EDTMP, e do diclorometilenobifosfonato de sódio - Clodronato) com 188Re para terapia de metastáses ósseas. Fosfonatos são inibidores da reabsorção óssea osteoclástica e são efetivos neste tratamento. As marcações do MDP, EDTMP e Clodronato com 188Re foram otimizadas utilizando como agente redutor o cloreto estanoso (SnCl2 2H2O) e como agente estabilizante o ácido ascórbico. As variáveis estudadas foram massa do ligante, massa do SnCl2.2H2O, massa do ácido ascórbico, tempo, pH e temperatura da reação. Os resultados mostraram que se obteve um excelente rendimento de marcação de 98% para o 188Re-MDP, de 83% para o 188Re-EDTMP e 85% para o 188Re-Clodronato. / The wide application of radiopharmaceuticals in nuclear medicine, representing 95% of procedures performed is in diagnosis, but in recent years, its application in therapeutic procedures has grown considerably. The radionuclides that emit ionizing particles (α, β, and Auger electrons) are indicated for the treatment of tumors. Malignant tumors account for approximately 12% of deaths and represent the third cause of mortality in Brazil. 188Re is one of the most attractive radioisotopes for a variety of therapeutic applications in nuclear medicine, oncology and cardiology interventions, is fully favorable and convenient because it is carrier free and can be obtained inexpensively in the form of a generator of 188W/188Re, and has a physical half-life of 16.9 hours and 100% of β-radiation emission. From the 2000s several investigations have been conducted involving molecules labeled with 188Re. Metastatic tumors are the most common form of malignancy in the skeleton. In metastatic cases the main goals of treatment are the prevention of pathological fractures and the promotion of survival with maximum preservation of function allowing the patient to maintain the greatest possible mobility and pain control. The objective of this study was to compare the labeling of various phosphonates (Sodium methylene diphosphonate - MDP, Ethylenediaminetetramethylene phosphonic acid - EDTMP, and sodium dichloromethylenediphosphonate - clodronate) with 188Re for bone metastases therapy. Phosphonates are inhibitors of osteoclastic bone resorption and are effective in treatment. The labeling of MDP, EDTMP and Clodronate with 188Re was optimized using stannous chloride (SnCl2·2H2O) as reducing agent, and ascorbic acid as stabilizing agent. The variables studied were the ligand mass, SnCl2.2H2O mass, mass of ascorbic acid, time, pH and temperature of the reaction. The results showed an excellent labeling yield of 98% for 188Re-MDP, 83% for 188Re-EDTMP and 85% for 188Re-Clodronate.
10

Estudo comparativo da marcação do anticorpo anti-CD20 com 188Re / Comparative studies of antibody anti-CD20 labeled with 188Re

Dias, Carla Roberta de Barros Rodrigues 24 February 2010 (has links)
A Medicina Nuclear é uma modalidade de particular importância em oncologia e a investigação de novos radiofármacos direcionados a tumores, seja para diagnóstico e/ou terapia, é uma área de interesse para os pesquisadores. Rituximab (RTX) é um anticorpo monoclonal (AcM) quimérico (IgG 1) que se liga especificamente ao antígeno CD20 com alta afinidade e tem sido usado com sucesso para tratar Linfoma Não-Hodgkin (LNH) de células-B. O antígeno CD20 é expresso sobre mais de 90% dos LNH de células-B. Tecnécio-99m (99mTc) e rênio-188 (188Re) representam um atrativo par de radionuclídeos para uso médico devido as favoráveis propriedades de decaimento para diagnóstico (99mTc: T1/2 = 6 h, radiação γ = 140 keV) e terapia (188Re: T1/2 = 17 h, radiação máxima = 2,12 MeV) e por causa de sua disponibilidade graças aos sistemas de geradores correspondentes 99Mo/99mTc e 188W/188Re. Estes dois radionuclídeos podem ser conjugados aos anticorpos usando métodos químicos similares. O objetivo geral deste trabalho foi estudar a marcação do AcM anti-CD20 (Rituximab) com o radioisótopo 188Re usando duas técnicas: método direto de marcação [188Re(V)] e método de marcação via núcleo carbonila [188Re(I)]. Além do controle de qualidade, o anticorpo radiomarcado foi submetido a estudo biológico in vivo, in vitro e ex vivo. Para a marcação direta, o RTX foi reduzido pela incubação com o agente redutor 2-mercaptoetanol para a geração de grupos sulfidrilas (-SH) e posteriormente marcado com 188Re(V), fazendo-se um amplo estudo de variáveis para se chegar a uma formulação otimizada. Para a marcação usando o núcleo carbonila foram usados os radioisótopos 99mTc e 188Re e dois procedimentos de radiomarcação: (1) RTX nativo marcado com 99mTc(I) e (2) RTX reduzido (RTXred) marcado com 99mTc(I)/188Re(I). Também foi feito um estudo de variáveis para se chegar a formulação otimizada. O método de controle de qualidade para avaliação da pureza radioquímica mostrou um bom rendimento de marcação (93%) para o método direto. Na marcação com o núcleo carbonila, os resultados mostraram que os grupos -SH do anticorpo reduzido são uma possível via de ligação. A formação do composto 99mTc(I)-RTXred foi mais rápida do que 188Re(I)- RTXred, que por sua vez mostrou melhor estabilidade em plasma humano e nenhuma transquelação no desafio a histidina ou cisteína. Os dois compostos mostraram boa afinidade de ligação e uma biodistribuição em camundongos portadores de tumor coerente com a biodistribuição normal do anticorpo e razoável captação no tumor provando a eficiência do método de marcação e potencial uso clínico. / Nuclear Medicine is an unique and important modality in oncology and the development of new tumor-targeted radiopharmaceuticals for both diagnosis and therapy is an area of interest for researchers. Rituximab (RTX) is a quimeric monoclonal antibody (mAb) (IgG 1) that specifically binds to CD20 antigen with high affinity and has been successfully used for the treatment of Non-Hodgkin Lymphoma (NHL) of cell B. The CD20 antigen is expressed over more than 90% of cell B NHL. Technetium-99m (99mTc) and rhenium-188 (188Re) are an attractive radionuclide pair for clinical use due to their favorable decay properties for diagnosis (99mTc: T1/2 = 6 h, γ radiation = 140 keV) and therapy (188Re: T1/2 = 17 h, maximum energy = 2.12 MeV) and to their availability in the form of 99Mo/99mTc and 188W/188Re generators. The radionuclides can be conjugated to mAb using similar chemical procedures. The aim of this work was to study the labeling of anti-CD20 mAb (RTX) with 188Re using two techniques: the direct labeling method [188Re(V)] and the labeling method via the carbonyl nucleus [188Re(I)]. Besides the quality control, the radiolabeled mAb was submitted to in vivo, in vitro and ex vivo biological studies. For the direct labeling, RTX was reducing by incubation with 2-mercaptoethanol for generating sulphydryl groups (-SH) and further labeled with 188Re(V), in a study of several parameters in order to reach an optimized formulation. The labeling via the carbonyl nucleus both 99mTc and 188Re were employed through 2 different procedures: (1) labeling of intact RTX with 99mTc(I) and (2) reduced RTX (RTXred) labeled with 99mTc(I)/188Re(I). Also a parameter study was performed to obtain an optimized formulation. The quality control method for evaluating the radiochemical purity showed a good labeling yield (93%) for the direct method. The labeling method via carbonyl group, the results showed that the SH groups of RTXred are a possible way of labeling. The formulation of 99mTc(I)-RTXred was faster than 188Re(I)-RTXred, that on the other hand showed better stability in human plasma and no transquelation in the cysteine or histidine challenge studies. Both compounds showed good binding affinity and a biodistribution in mice bearing tumor compatible with the normal mAb distribution and a reasonable tumor uptake proving the efficiency of the labeling and the potential clinical use.

Page generated in 0.0472 seconds