• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 4
  • Tagged with
  • 17
  • 17
  • 17
  • 11
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Retreatability of root canals obturated using a bioceramic sealer and gutta percha

Maronga, Godfrey Obaigwa January 2020 (has links)
Magister Scientiae Dentium - MSc(Dent) / Statement of problem: Although bioceramic endodontic sealer cements offer various advantages over conventional zinc oxide-based and resin-based cements, questions have been raised about the ability to retreat root canals that have been sealed using these cements. Aims and Objectives: The aim of the study was to determine the retreatability of root canals sealed using a bioceramic calcium silicate-based sealer cement. The objectives were to determine the possibility of achieving working length and apical patency when obturation is done with the master GP placed at working length and when it is short by 3mm. The time it took to achieve these parameters when it was possible to achieve them was also determined. The role of XP Endo Finisher R, a supplementary retreatment file, in achieving working length and apical patency was also to be evaluated. However, this latter aspect was eliminated after the pilot study, when it was found not to have an effect in regaining working length and apical patency.
2

Analysis of coronal discoloration from commonly used obturation materials.

Elkhazin, Mohamed M. A. January 2007 (has links)
<p>The objective of this study was to assess coronal discoloration due to four commonly used endodontic sealers with gutta-percha, using spectrophotometric analysis. Extracted human teeth were obturated with the experimental sealers and GP. The sealers that were tested included AH Plus, EndoRez, and Kerr Pulp Canal Sealer. The teeth were maintained in a moist environment at 37 C. Immediate pretreatment readings of the crowns of the extracted teeth with a spectrometer were used as baseline data. Subsequent readings were taken every two weeks for two months. Results were analysed using Wilcoxson Signed Rank sum test and Kruskal Wallis test.</p>
3

Analysis of coronal discoloration from commonly used obturation materials.

Elkhazin, Mohamed M. A. January 2007 (has links)
<p>The objective of this study was to assess coronal discoloration due to four commonly used endodontic sealers with gutta-percha, using spectrophotometric analysis. Extracted human teeth were obturated with the experimental sealers and GP. The sealers that were tested included AH Plus, EndoRez, and Kerr Pulp Canal Sealer. The teeth were maintained in a moist environment at 37 C. Immediate pretreatment readings of the crowns of the extracted teeth with a spectrometer were used as baseline data. Subsequent readings were taken every two weeks for two months. Results were analysed using Wilcoxson Signed Rank sum test and Kruskal Wallis test.</p>
4

Influência do tempo após manipulação na citotoxicidade e genotoxicidade de diferentes cimentos endodônticos /

Oliveira, Tatiana Rocha de. January 2011 (has links)
Orientador: Carlos Henrique Ribeiro Camargo / Banca: Cácio de Moura Netto / Banca: Marcia Carneiro Valera / Resumo: Objetivo deste estudo foi avaliar a citotoxicidade e a genotoxidade de quatro cimentos endodônticos: AH Plus (Dentsply De Trey, Alemanha); Endo Rez (Ultradent, USA); RoekoSeal (Coltene Whaledent, Alemanha) e o Cimento experimental à base de óleo-resina de Copaiba (Brasil). A avaliação foi realizada em três diferentes tempos após manipulação: 0h, 12h e 24h. Os espécimes foram preparados, deixados por 12 e 24h em estufa (37 °C a 100% umidade a 5% de CO2) e colocados em contato com meio de cultura (82,4 mm2 superfície/ml) por 24 h. Células V79 foram expostas à diferentes diluições dos cimentos por 24 h e a viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro. Para o teste de genotoxicidade os extratos que apresentaram concentrações de citototoxicidade média foram selecionados para o teste cometa após 24 h de exposição. A viabilidade celular e o dano ao DNA foram comparados aos grupos controles e analisados pelos testes de Kruskal-Wallis e Dunn (p<0,05). No teste de citotoxicidade, todos os cimentos apresentaram diferença significativa em relação ao controle, com exceção do RoekoSeal. A viabilidade celular de acordo com cimento utliizado pode ser classificada da maior toxicidade para a menor seguindo: EndoREZ > AH Plus > Copaíba > RoekoSeal. O dano ao DNA verificado no teste cometa pode ser classificado do maior para o menor em: EndoREZ > RoekoSeal > AH Plus > Copaíba. Conclui-se que o cimento EndoREZ é citotóxico e genotóxico nos tempos e diluições estudadas / Abstract: The aim of this study was to evaluate cytotoxicity and the genotoxicity of four different root canal sealers, AH Plus (Dentsply De Trey, Germany); Endo REZ (Ultradent, USA); RoekoSeal (Coltene Whaledent, Germany) and the experimental root canal sealer based on Copaiba oil-resin sealer (Brazil). The evaluation of the materials was performed after three different times of manipulation: 0h, 12h and 24h. The specimens were prepared, incubated in a humidified incubator (37°C with 5% CO2 in air for 12h and 24h) and them put in contact with the culture medium (82,4 mm2surface/ml) during 24h. V79 cells were exposed at different dilutions of the sealers during 24h and the cell's viability was measured by the MTT test in a spectrophotometer. For the genotoxicity tests, the extracts from the concentrations with medium citotoxicity were selected for the comet assay after 24h of exposure. The cellular viability and the DNA damage were compared with the control groups and analyzed by the tests of Kruskal-Wallis and Dunn (p<0,05). The citotoxicity test showed that all root canal sealers showed a statistically significant difference when compared with the control group, with the exception of the RoekoSeal. The ranking of cell's viability according with sealer utilized from the most to the least toxicic material was: EndoRez > AH Plus > Copaíba > RoekoSeal. The ranking of DNA damage verified at the comet assay, from the most to the least was: EndoREZ > RoekoSeal > AH Plus > Copaíba. It was conclude that, at the times and dilutions studied, the EndoREZ sealer is genotoxic and citotoxic / Mestre
5

Analysis of coronal discoloration from commonly used obturation materials

Elkhazin, Mohamed M. A. January 2007 (has links)
Magister Scientiae Dentium - MSc(Dent) / The objective of this study was to assess coronal discoloration due to four commonly used endodontic sealers with gutta-percha, using spectrophotometric analysis. Extracted human teeth were obturated with the experimental sealers and GP. The sealers that were tested included AH Plus, EndoRez, and Kerr Pulp Canal Sealer. The teeth were maintained in a moist environment at 37 C. Immediate pretreatment readings of the crowns of the extracted teeth with a spectrometer were used as baseline data. Subsequent readings were taken every two weeks for two months. Results were analysed using Wilcoxson Signed Rank sum test and Kruskal Wallis test. / South Africa
6

AVALIAÇÃO DA BIOCOMPATIBILIDADE DE 4 CIMENTOS ENDODÔNTICOS:ESTUDO EM TECIDO CONJUNTIVO SUBCUTÂNEO DE RATOS / Analysis of the biocompatibility of four endodontic sealers: study in the subcutaneous connective tissue of rats

Silveira, Camila Maggi Maia 27 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 CAMILAMAIA.pdf: 8374902 bytes, checksum: 212930917cb97231aed01c002e3154e7 (MD5) Previous issue date: 2008-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was evaluate the biocompatibility of four root canal sealers, Epiphany, AH Plus, Pulp Canal Sealer, Sealapex. Sterile polyethylene tubes containing freshly mixed test materials were inserted into the connective tissues of the sixty rats. The animals were divided into four groups. After anesthesia, the dorsal skin was shaved, disinfected, incisioned and two pocket were carefully prepared by blunt dissection and each animal received two implantations in opposite sides, one containing the material nd another as control (empty polyethylene tube). After periods of 7, 15 and 30 days, the implants were removed with the surrounding tissue and immersed in 10% formalin solution for 48 hours. After fixing the tissue it was processed for paraffin embedding which were cut in serial sections with the microtome set at 4 μm, stained with hematoxylin and eosin and assessed by light microscopy. The descriptive analysis was conducted by a pathologist who was blinded to which group and experimental period the glass slides pertained to, following the criteria: A) the thickness of the fibrous capsule: thin, intermediate or thick; B) Connective tissue composition: fibrous or loose, necrosis, nerve, blood vessels; C) the severity of the inflammatory reaction: mild, moderate, severe; D) presence of giant cells. The results revealed that after a period of 7 days all the sealers induced moderate-to-severe inflammatory reaction and Sealapex presented mild inflammatory reaction. At the 15-day, Epiphany and AH Plus sealers conducted to moderate inflammatory reaction, Pulp Canal Sealer severe inflammatory reaction, and Sealapex had the same intensity. After 30 days of the implantation of the sealers, mild inflammatory reactions were observed for the Epiphany, AH Plus and Sealapex, and moderate inflammatory reaction for the Pulp Canal Sealer. The results of this study revealed that Sealapex presented lowest level of inflammatory reaction in all the observed periods, yet all the sealers induced acceptable biological compatibility. More extensive experiments will be necessary to fully predict the clinical behavior of the sealers in patients undergoing endodontic therapy. / O objetivo deste estudo foi avaliar a biocompatibilidade de quatro cimentos endodônticos: Epiphany, AH Plus, Pulp Canal Sealer EWT e Sealapex. Tubos de polietileno contendo os materiais prontamente manipulados foram introduzidos no tecido conjuntivo subcutâneo de 60 ratos. Os animais foram divididos em 4 grupos. Após anestesia, tricotomia, desinfecção, incisão e divulsão tecidual, cada animal recebeu dois implantes contralaterais: um implante contendo o material e um controle (tubo vazio). Após os períodos de sete, 15 e 30 dias os implantes foram removidos com margem de tecido e fixados em solução de formol a 10% por 48 horas. Após a fixação das amostras, procedeu-se a remoção dos tubos, inclusão em blocos de parafina e cortes seriados de 4μm, que foram corados com Hematoxilina e Eosina e examinados por microscopia óptica de luz comum. A análise descritiva das lâminas foi realizada por um Patologista, que desconhecia a que grupo e período experimental as lâminas pertenciam, seguindo os seguintes critérios; A) Espessura da cápsula: delgada, intermediária ou espessa; B) Constituição do tecido conjuntivo: fibroso ou frouxo; presença de necrose; feixes vásculo-nervosos; eventos vasculares; C) Severidade do infiltrado inflamatório: discreto, moderado ou intenso; D) Presença de células gigantes multinucleadas inflamatórias (CGMI). Os resultados mostraram que depois de sete dias todos os cimentos apresentaram uma resposta inflamatória de moderada a intensa e o Sealapex mostrou-se com resposta inflamatória discreta. Com 15 dias os cimentos Epiphany e AH Plus apresentaram resposta moderada; para o Pulp Canal Sealer EWT a resposta foi severa e o Sealapex manteve-se com infiltrado inflamatório discreto. No final do período de avaliação, 30 dias, as reações teciduais apresentaram-se discretas para os cimentos AH Plus, Epiphany, Sealapex e moderada para o Pulp Canal Sealer EWT. Os resultados deste estudo revelaram que o cimento Sealapex foi o que apresentou menor resposta inflamatória em todos os períodos, ainda que todos os cimentos tenham demonstrado compatibilidade biológica aceitável. Contudo mais experimentos serão necessários para o total conhecimento do comportamento clínico dos cimentos em dentes submetidos a terapia endodôntica.
7

Comparação in vitro da adesão de diferentes cimentos endodônticos à dentina radicular e aos componentes sólidos da obturação

Barbizam, João Vicente Baroni [UNESP] 26 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-26Bitstream added on 2014-06-13T18:42:18Z : No. of bitstreams: 1 barbizam_jvb_dr_arafo.pdf: 425567 bytes, checksum: 60f631b7710a86a21e5f8d7f64f0ba90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo é avaliar in vitro, por meio dos testes de push-out e tração, a adesão de diferentes cimentos endodônticos à dentina e aos componentes sólidos da obturação, guta-percha e resilon. Sessenta dentes humanos uniradiculares tiveram suas coroas removidas e foram divididos em três gupos de vinte dentes. Cada grupo foi instrumentado pela técnica rotatória até uma lima tipo Profile 40.04 e alargados com uma broca de preparo de pino com 1,5 mm de diâmetro, sob irrigação com hipoclorito de sódio 2,5% (NaOCl) seguido de irrigação final com EDTA 17%; gel de clorexidina 2%(CHX) alternado com soro fisiológico e seguido por EDTA 17% ou apenas com soro fisiológico, como controle. A seguir, foram obturados com os cimentos AH 26, Endo Fill, Endo Rez e Epiphany. Após 48 horas de incubação a 37 graus Celsius e 100% de umidade, os dentes foram cortados tranversalmente em discos de 2 mm de espessura. As amostras foram submetidas à força de compressão pelo teste de push-out. Para o teste de tração, discos de guta-percha e resilon foram criados e os cimentos AH 26, Endo Fill, Endo Rez e Epiphany foram colocados em contato com o material sólido da obturação por meio de anéis metálicos contendo os cimentos em seu interor. Após incubação as amostras foram submetidas ao teste de tração. Ambos os testes foram realizados em máquina de ensaios (1mm/min) e os resultados expressos em Mpa. O teste Anova e Newman-Keuls evidenciaram que cimento Epiphany apresentou maior adesão à dentina no teste de push-out, seguido pelos cimentos Endo Rez e AH 26 que foram semelhantes entre si e, por último o cimento Endo Fill. O uso da CHX aumentou a adesão à dentina de todos os cimentos testados. No teste de tração aos componentes sólidos, o cimento AH 26 mostrou ter uma maior adesão que os demais cimentos, que foram semelhantes entre si. / The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin and to the filling core material, using push-out and tensile tests. Sixty extracted single-rooted human teeth were divided into three groups and evenly instrumented with the crown-down technique up to a file #55 followed by a root canal enlargement using a 1,5 mm diameter post drill. Teeth were prepared under irrigation with 2.5% NaOCl + EDTA 17 %, 2% CHX associated to a saline solution + EDTA 17% or just saline solution, as control. All teeth were completely filled with AH 26, Endo Rez, Endo Fill and Epiphany sealers. After 48 hours of storage in 100% humidity at 37°C, all samples were sectioned transversally into 2mm thickness disks and the push-out tests were performed. For the tensile tests, gutta-percha and resilon disks were created and metallic rings with the sealers were positioned over the core material disks, in the same time/temperature conditions. Both push-out and tensile tests were performed using the universal testing machine (1 mm/min) and the maximum load at failure expressed in MPa. Two-way ANOVA and Newman-Keuls tests showed that Ephipany sealant presented the highest bond strength to dentin followed by Endo REZ and AH 26 that were similar to each other and Endo Fill with the lowest values of bonding to dentin. 2% CHX irrigation increased the bonding strength of all sealers to dentin. Tensile tests to the filling core materials showed that AH 26 presented the highest values of bonding. No statistical differences were found between the other sealers.
8

Influência do tempo após manipulação na citotoxicidade e genotoxicidade de diferentes cimentos endodônticos

Oliveira, Tatiana Rocha de [UNESP] 01 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-01Bitstream added on 2014-06-13T19:52:05Z : No. of bitstreams: 1 oliveira_tr_me_sjc.pdf: 620321 bytes, checksum: e26df581da35d3b46846dc2f7153d000 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo deste estudo foi avaliar a citotoxicidade e a genotoxidade de quatro cimentos endodônticos: AH Plus (Dentsply De Trey, Alemanha); Endo Rez (Ultradent, USA); RoekoSeal (Coltene Whaledent, Alemanha) e o Cimento experimental à base de óleo-resina de Copaiba (Brasil). A avaliação foi realizada em três diferentes tempos após manipulação: 0h, 12h e 24h. Os espécimes foram preparados, deixados por 12 e 24h em estufa (37 °C a 100% umidade a 5% de CO2) e colocados em contato com meio de cultura (82,4 mm2 superfície/ml) por 24 h. Células V79 foram expostas à diferentes diluições dos cimentos por 24 h e a viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro. Para o teste de genotoxicidade os extratos que apresentaram concentrações de citototoxicidade média foram selecionados para o teste cometa após 24 h de exposição. A viabilidade celular e o dano ao DNA foram comparados aos grupos controles e analisados pelos testes de Kruskal-Wallis e Dunn (p<0,05). No teste de citotoxicidade, todos os cimentos apresentaram diferença significativa em relação ao controle, com exceção do RoekoSeal. A viabilidade celular de acordo com cimento utliizado pode ser classificada da maior toxicidade para a menor seguindo: EndoREZ > AH Plus > Copaíba > RoekoSeal. O dano ao DNA verificado no teste cometa pode ser classificado do maior para o menor em: EndoREZ > RoekoSeal > AH Plus > Copaíba. Conclui-se que o cimento EndoREZ é citotóxico e genotóxico nos tempos e diluições estudadas / The aim of this study was to evaluate cytotoxicity and the genotoxicity of four different root canal sealers, AH Plus (Dentsply De Trey, Germany); Endo REZ (Ultradent, USA); RoekoSeal (Coltene Whaledent, Germany) and the experimental root canal sealer based on Copaiba oil-resin sealer (Brazil). The evaluation of the materials was performed after three different times of manipulation: 0h, 12h and 24h. The specimens were prepared, incubated in a humidified incubator (37°C with 5% CO2 in air for 12h and 24h) and them put in contact with the culture medium (82,4 mm2surface/ml) during 24h. V79 cells were exposed at different dilutions of the sealers during 24h and the cell’s viability was measured by the MTT test in a spectrophotometer. For the genotoxicity tests, the extracts from the concentrations with medium citotoxicity were selected for the comet assay after 24h of exposure. The cellular viability and the DNA damage were compared with the control groups and analyzed by the tests of Kruskal-Wallis and Dunn (p<0,05). The citotoxicity test showed that all root canal sealers showed a statistically significant difference when compared with the control group, with the exception of the RoekoSeal. The ranking of cell’s viability according with sealer utilized from the most to the least toxicic material was: EndoRez > AH Plus > Copaíba > RoekoSeal. The ranking of DNA damage verified at the comet assay, from the most to the least was: EndoREZ > RoekoSeal > AH Plus > Copaíba. It was conclude that, at the times and dilutions studied, the EndoREZ sealer is genotoxic and citotoxic
9

Comparação "in vitro" da adesão de diferentes cimentos endodônticos à dentina radicular e aos componentes sólidos da obturação /

Barbizam, João Vicente Baroni. January 2006 (has links)
Orientador: Mário Tanomaru Filho / Banca: Marco Antônio Húngaro Duarte / Banca: Manoel Damião de Souza Neto / Banca: Luis Geraldo Vaz / Banca: Idomeo Bonetti Filho / Resumo: O objetivo desse estudo é avaliar "in vitro", por meio dos testes de push-out e tração, a adesão de diferentes cimentos endodônticos à dentina e aos componentes sólidos da obturação, guta-percha e resilon. Sessenta dentes humanos uniradiculares tiveram suas coroas removidas e foram divididos em três gupos de vinte dentes. Cada grupo foi instrumentado pela técnica rotatória até uma lima tipo Profile 40.04 e alargados com uma broca de preparo de pino com 1,5 mm de diâmetro, sob irrigação com hipoclorito de sódio 2,5% (NaOCl) seguido de irrigação final com EDTA 17%; gel de clorexidina 2%(CHX) alternado com soro fisiológico e seguido por EDTA 17% ou apenas com soro fisiológico, como controle. A seguir, foram obturados com os cimentos AH 26, Endo Fill, Endo Rez e Epiphany. Após 48 horas de incubação a 37 graus Celsius e 100% de umidade, os dentes foram cortados tranversalmente em discos de 2 mm de espessura. As amostras foram submetidas à força de compressão pelo teste de push-out. Para o teste de tração, discos de guta-percha e resilon foram criados e os cimentos AH 26, Endo Fill, Endo Rez e Epiphany foram colocados em contato com o material sólido da obturação por meio de anéis metálicos contendo os cimentos em seu interor. Após incubação as amostras foram submetidas ao teste de tração. Ambos os testes foram realizados em máquina de ensaios (1mm/min) e os resultados expressos em Mpa. O teste Anova e Newman-Keuls evidenciaram que cimento Epiphany apresentou maior adesão à dentina no teste de push-out, seguido pelos cimentos Endo Rez e AH 26 que foram semelhantes entre si e, por último o cimento Endo Fill. O uso da CHX aumentou a adesão à dentina de todos os cimentos testados. No teste de tração aos componentes sólidos, o cimento AH 26 mostrou ter uma maior adesão que os demais cimentos, que foram semelhantes entre si. / Abstract: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin and to the filling core material, using push-out and tensile tests. Sixty extracted single-rooted human teeth were divided into three groups and evenly instrumented with the crown-down technique up to a file #55 followed by a root canal enlargement using a 1,5 mm diameter post drill. Teeth were prepared under irrigation with 2.5% NaOCl + EDTA 17 %, 2% CHX associated to a saline solution + EDTA 17% or just saline solution, as control. All teeth were completely filled with AH 26, Endo Rez, Endo Fill and Epiphany sealers. After 48 hours of storage in 100% humidity at 37°C, all samples were sectioned transversally into 2mm thickness disks and the push-out tests were performed. For the tensile tests, gutta-percha and resilon disks were created and metallic rings with the sealers were positioned over the core material disks, in the same time/temperature conditions. Both push-out and tensile tests were performed using the universal testing machine (1 mm/min) and the maximum load at failure expressed in MPa. Two-way ANOVA and Newman-Keuls tests showed that Ephipany sealant presented the highest bond strength to dentin followed by Endo REZ and AH 26 that were similar to each other and Endo Fill with the lowest values of bonding to dentin. 2% CHX irrigation increased the bonding strength of all sealers to dentin. Tensile tests to the filling core materials showed that AH 26 presented the highest values of bonding. No statistical differences were found between the other sealers. / Doutor
10

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Brito Júnior, Manoel 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls

Page generated in 0.2058 seconds