• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 2
  • Tagged with
  • 11
  • 11
  • 11
  • 9
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simulation of the upgraded Phase-1 Trigger Readout Electronics of the Liquid-Argon Calorimeter of the ATLAS Detector at the LHC

Grohs, Johannes Philipp 10 May 2016 (has links) (PDF)
In the context of an intensive upgrade plan for the Large Hadron Collider (LHC) in order to provide proton beams of increased luminosity, a revision of the data readout electronics of the Liquid-Argon-Calorimeter of the ATLAS detector is scheduled. This is required to retain the efficiency of the trigger at increased event rates despite its fixed bandwidth. The focus lies on the early digitization and finer segmentation of the data provided to the trigger. Furthermore, there is the possibility to implement new energy reconstruction algorithms which are adapted to the specific requirements of the trigger. In order to constitute crucial design decisions, such as the digitization scale or the choice of digital signal processing algorithms, comprehensive simulations are required. High trigger efficiencies are decisive at it for the successful continuation of the measurements of rare StandardModel processes as well as for a high sensitivity to new physics beyond the established theories. It can be shown that a significantly improved resolution of the missing transverse energy calculated by the trigger is achievable due to the revised segmentation of the data. Various energy reconstruction algorithms are investigated in detail. It can be concluded that these will facilitate reliable trigger decisions for all expected working conditions and for the whole possible energy range.
2

Simulation of signal and background processes for collider experiments

Schumann, Steffen 12 March 2008 (has links) (PDF)
This thesis is concerned with the theoretical modelling of scattering processes as they are studied at high-energy collider experiments. Special attention is thereby given to an accurate simulation of multi-particle final states that are expected to constitute the key signatures for the existence of physics beyond the Standard Model of particle physics.
3

Studies of Charged Higgs Boson Observability in the H->tb Decay at the ATLAS Experiment within the Minimal Supersymmetric Standard Model / Studien zur Beobachtbarkeit von elektrisch geladenen Higgs Bosonen im H->tb Zerfallskanal innerhalb des Minimal Supersymmetrischen Standardmodells am ATLAS Experiment

Göpfert, Thomas 19 January 2011 (has links) (PDF)
This thesis presents a Monte Carlo study of the search for charged Higgs bosons heavier than the mass of the top quark within the Minimal Supersymmetric Standard Model (MSSM) at the ATLAS experiment at the CERN Large Hadron Collider. Charged Higgs bosons are predicted in many non-minimal Higgs extensions of the Standard Model. Their discovery would be a clear signal for the existence of New Physics beyond the Standard Model, possibly the first experimental evidence to be found if the MSSM is realized in nature. The feasibility of detecting the heavy charged Higgs boson with a mass up to 600 GeV is studied in the decay channel H->tb for an integrated luminosity of 30 inverse femtobarns at a center-of-mass energy of 10 TeV. A major difficulty for charged Higgs boson reconstruction is the combinatorial background in the complex multi-jet final state environment. It is shown that this can be overcome by applying a kinematic fitting procedure and by a subsequent cut-based event and candidate selection. An iterative solution of the developed kinematic fit with non-linear constraints is presented. In addition, the reconstruction of charged Higgs bosons makes high demands on the ability to identify jets containing b-hadrons. A special b-tagging algorithm is introduced and a comparison with first ATLAS data is presented showing good agreement of the expected performance. This study is performed with a realistic simulation of the ATLAS detector and takes into account all dominant experimental uncertainties and statistical uncertainties arising from limited Monte Carlo statistics. The result is given in terms of discovery and exclusion contours in the (m(H), tan(beta)) parameter space in the mhmax scenario of the MSSM. This study indicates that the heavy charged Higgs boson can be discovered in this decay channel only for large values of tan(beta). It, however, can contribute to a combined H sensitivity including other decay channels. Compared to previous studies the discovery reach could be improved. / Die vorliegende Arbeit präsentiert eine Monte Carlo Studie zur Suche nach geladenen Higgs Bosonen mit einer Masse größer als die des top Quarks im Kontext des Minimal Supersymmetrischen Standardmodells (MSSM) am ATLAS Experiment am CERN Large Hadron Collider. Geladene Higgs Bosonen werden von vielen Erweiterungen des Standardmodells vorhergesagt. Ihre Entdeckung wäre ein klares Indiz für neue Physik jenseits des Standardmodells, möglicherweise der erste experimentelle Befund für das MSSM. Eine Machbarkeitsstudie zur Entdeckung geladener Higgs Bosonen mit Massen bis zu 600 GeV im Zerfallskanal H->tb für eine integrierte Luminosität von 30 inversen femtobarn und einer Schwerpunktsenergie von 10 TeV wird vorgestellt. Eine der Hauptschwierigkeiten bei der Rekonstruktion geladener Higgs Bosonen ist der durch den komplexen Endzustand mit vielen Jets auftretende kombinatorische Untergrund. Es wird gezeigt, dass die Rekonstruktion durch Anwendung eines kinematischen Fits mit anschließender schnittbasierter Ereignis- und Kandidatenselektion möglich ist. Eine iterative Lösung des entwickelten kinematischen Fits mit nicht-linearen Zwangsbedingungen wird vorgestellt. Des Weiteren stellt die Rekonstruktion geladener Higgs Bosonen hohe Ansprüche an die Möglichkeit, Jets, welche b-Hadronen beinhalten, zu identifizieren. Ein spezieller b-tagging Algorithmus wird vorgestellt und ein Vergleich mit den ersten ATLAS Daten zeigt eine gute Übereinstimmung mit den erwarteten Eigenschaften. Die Studie wurde mit einer realistischen ATLAS Detektorsimulation durchgeführt und beinhaltet alle dominanten experimentellen Unsicherheiten sowie die statistische Unsicherheiten aufgrund begrenzt vorhandener simulierter Ereignisse. Die erwarteten Entdeckungs- und Ausschlusskonturen im mhmax Szenario des MSSM werden als Funktion der geladenen Higgs Boson Masse und tan(beta) gegeben. Die durchgeführte Studie zeigt, dass geladene Higgs Bosonen in diesem Zerfallskanal nur bei großen Werten von tan(beta) entdeckt werden können. Dennoch kann dieser Zerfallskanal zur H Sensitivität beitragen, wenn andere Zerfallskanäle mit in Betracht gezogen werden. Im Vergleich zu vorherigen Studien konnte die Sensitivität erhöht werden.
4

Emittance Compensation for SRF Photoinjectors

Vennekate, Hannes 20 September 2017 (has links) (PDF)
The advantages of contemporary particle injectors are high bunch charges and good beam quality in the case of normal conducting RF guns and increased repetition rates in the one of DC injectors. The technological edge of the concept of superconducting radio frequency injectors is to combine the strengths of both these sides. As many future accelerator concepts, such as energy recovery linacs, high power free electron lasers and certain collider designs, demand particle sources with high bunch charges and high repetition rates combined, applying the superconductivity of the accelerator modules to the injector itself is the next logical step. However, emittance compensation — the cornerstone for high beam quality — in case of a superconducting injector is much more challenging than in the normal conducting one. The use of simple electromagnets generating a solenoid field around the gun’s resonator interferes with its superconducting state. Hence, it requires novel and sophisticated techniques to maintain the high energy gain inside the gun cavity, while at the same time alleviating the detrimental fast transverse emittance growth of the bunch. In the case of the ELBE accelerator at the Helmholtz-Zentrum Dresden-Rossendorf, a superconducting electron accelerator provides beam for several independent beamlines in continuous wave mode. The applications include IR to THz free electron lasers, neutron and positron generation, to Thompson backscattering with an inhouse TW laser, and hence, call for a flexible CW injector. Therefore, the development of a 3.5 cell superconducting electron gun was initiated in 1997. The focus of this thesis lies on three approaches of transverse emittance compensation for this photoinjector: RF focusing, the installation of a superconducting solenoid close to the cavity’s exit, and the introduction of a transverse electrical mode of the RF field in the resonator. All three methods are described in theory, examined by numerical simulation, and experimentally reviewed in the particular case of the ELBE SRF Gun II at HZDR and a copy of its niobium resonator at Thomas Jefferson National Laboratory, Newport News, VA, USA.
5

Automating methods to improve precision in Monte-Carlo event generation for particle colliders / Automatisierung von Methoden zur Verbesserung der Praezision bei der Monte-Carlo Eventgeneration fuer Teilchenbeschleunigerexperimente

Gleisberg, Tanju 24 April 2008 (has links) (PDF)
This thesis concerns with numerical methods for a theoretical description of high energy particle scattering experiments. It focuses on fixed order perturbative calculations, i.e. on matrix elements and scattering cross sections at leading and next-to-leading order. For the leading order a number of algorithms for the matrix element generation and the numeric integration over the phase space are studied and implemented in a computer code, which allows to push the current limits on the complexity of the final state and the precision. For next-to-leading order calculations necessary steps towards a fully automated treatment are performed. A subtraction method that allows a process independent regularization of the divergent virtual and real corrections is implemented, and a new approach for a semi-numerically evaluation of one-loop amplitudes is investigated.
6

QCD jet evolution at high and low scales / QCD Jet Evolution an hohen und niedrigen Skalen

Winter, Jan-Christopher 23 April 2008 (has links) (PDF)
This thesis deals with a broad range of aspects that concern the simulation of QCD jet physics by Monte Carlo event generators. Phenomenological work is presented in validating the CKKW approach for merging tree-level matrix elements and parton showers. In the second part the main project is documented comprising the definition, realization and verification of a new QCD colour-dipole cascade. Finally, a new cluster-hadronization model is introduced.
7

Event generation at lepton colliders / Generierung von Ereignissen an Leptonbeschleunigern

Kuhn, Ralf 01 September 2002 (has links) (PDF)
The Monte-Carlo simulation package APACIC++/AMEGIC++ is able to describe current and future electron-positron annihilation experiments, namely the LEP collider at CERN and the TESLA collider at DESY. APACIC++ is responsible for the complete generation of one event and AMEGIC++ deals with the exact calculation of matrix elements. The development of both programs was the major task of my thesis. / Das Monte Carlo Simulationspaket APACIC++/AMEGIC++ ist in der Lage Elektron-Positron Annihilationsexperimente wie sie bei Lep am Cern stattfanden und zukuenftig an einem Linearbeschleuniger, z.B. Tesla am Desy durchgefuehrt werden zu beschreiben. Dabei ist APACIC++ verantwortlich fuer die gesamte Generierung eines Ereignisses und AMEGIC++ ein dedizierter Matrixelement-Generator. Die Entwicklung beider Programme war das Hauptthema meiner Dissertation.
8

Measurement of the Partial Widths Ratio Gamma(Ds*+ -> Ds+ pi0) / Gamma(Ds*+ -> Ds+ gamma) at the BABAR Experiment / Messung des Partialbreitenverhältnisses Gamma(Ds*+ -> Ds+ pi0) / Gamma(Ds*+ -> Ds+ gamma) mit dem BABAR-Experiment

Dickopp, Martin 11 July 2004 (has links) (PDF)
Unter Benutzng von 90.4/fb Daten, die das BABAR-Experiment in den Jahren 1999 bis 2002 genommen hat, wurden die Zerfälle Ds*+ -> Ds+ pi0 und Ds*+ -> Ds+ gamma mit zwei verschiedenen Methoden rekonstruiert. Die Rekonstruktions-Effizienzen wurden mittels Signal-Monte Carlo-Ereignissen und D*0-Zerfällen ermittelt. Auf diese Weise wurde das Partialbreiten-Verhältnis Gamma(Ds*+ -> Ds+ pi0) / Gamma(Ds*+ -> Ds+ gamma) auf vier verschiedene Weisen gemessen. Zusätzlich wurde das Partialbreiten-Verhältnis Gamma(D*0 -> D0 pi0) / Gamma(D*0 -> D0 gamma) gemessen. / Using 90.4/fb of data taken at the BABAR experiment in the years 1999 to 2002, the decays Ds*+ -> Ds+ pi0 and Ds*+ -> Ds+ gamma have been reconstructed with two different methods. Signal Monte Carlo events as well as D*0 decays have been used to determine the reconstruction efficiencies. Thereby, the partial widths ratio Gamma(Ds*+ -> Ds+ pi0) / Gamma(Ds*+ -> Ds+ gamma) has been measured in four different ways. Additionally, the partial widths ratio Gamma(D*0 -> D0 pi0) / Gamma(D*0 -> D0 gamma) has been measured.
9

Das Lichtpulsersystem des elektromagnetischen CsI(Tl)-Kalorimeters des Babar-Detektors / The Light Pulser System of the Electromagnetic CsI(Tl) Calorimeter of the Babar Detector

Kocian, Martin Lukas 18 November 2000 (has links) (PDF)
A light pulser system for the Babar CsI(Tl) calorimeter, capable of monitoring the light yield of the 6580 crystals and of checking the function and linearity of the readout electronics, was developed in a collaboration with groups from Bochum and Edinburgh. The light pulser system is based on the coupling of light from Xenon flashlamps through optical fibers into the individual crystals. The absolute intensity is measured by two special reference systems whose stability is monitored using a radioactive source. During the construction phase the light pulser was used to check the electronics in order to ensure its functioning before the insertion of the calorimeter into the detector where the preamplifier electronics is inaccessable for repair. In monitoring the short term performance of the light pulser system, the stability over one week is better than 0.15 %. Over six months between February and August 2000 the crystal response, as measured by the light pulser, of the three rings of the endcap that are closest to the beam dropped by up to 2 % in comparison with the three outer rings of the endcap, due to radiation damage. Through linearity measurements with the light pulser a flaw in the ADC boards of the calorimeter electronics, which will be fixed in the near future, and cross-talk between channels was found. By a software correction of these effects implemented by members of the collaboration an improvement of the energy resolution of the calorimeter was achieved. / Fuer das CsI(Tl)-Kalorimeter des Babar-Detektors wurde in Zusammenarbeit mit Gruppen aus Bochum und Edinburgh ein Lichtpulsersystem entwickelt, das in der Lage ist, die Lichtausbeute der 6580 Kristalle zu monitorieren und die Funktionsfaehigkeit und Linearitaet der Kalorimeterelektronik zu ueberpruefen. Das Lichtpulsersystem basiert auf der Einkopplung des Lichts von Xenon-Blitzlampen ueber Lichtleitfasern in einzelne Kristalle. Die absolute Lichtmenge wird durch zwei spezielle Lichtnormale gemessen, deren Stabilitaet durch eine radioaktive Quelle monitoriert wird. In der Aufbauphase kam der Lichtpulser fuer die Ueberpruefung der Elektronik zum Einsatz, um deren Funktionsfaehigkeit sicherzustellen, bevor das Kalorimeter in den Detektor eingebaut wurde, weil danach die Vorverstaerkerelektronik fuer Reparaturen nicht mehr zugaenglich war. In der Monitorierung ist die Kurzzeitstabilitaet des Lichtpulsersystems ueber eine Woche besser als 0,15 %. Ueber sechs Monate zwischen Februar und August 2000 sank, bedingt durch Strahlenschaeden, die mit dem Lichtpulser gemessene Antwort der Kristalle fuer die strahlnaechsten drei Ringe der Endkappe um bis zu 2 % staerker als in den aeusseren drei Ringen der Endkappe. Durch die Linearitaetsmessungen mit dem Lichtpulser konnte ein Fehler in der Kalorimeterelektronik im Bereich der ADC-Karten, der in naher Zukunft behoben werden wird, sowie ein Uebersprechen zwischen den Kanaelen gefunden werden. Durch Softwarekorrekturen dieser Effekte von seiten der Kollaboration konnte eine Verbesserung der Energieaufloesung des Kalorimeters erreicht werden.
10

Entwicklung zweier Spektrometer für laserbeschleunigte Protonenstrahlen

Richter, Tom 10 October 2013 (has links) (PDF)
Durch die Fokussierung eines ultrakurzen und hochintensiven Laserpulses auf ein Festkörpertarget können Pulse von Protonen und anderen positiv geladenen Ionen mit Teilchenenergien von einigen MeV pro Nukleon erzeugt werden. Die Charakterisierung dieser Teilchenstrahlung erfordert die Identifizierung der Ionenspezies und die Bestimmung ihrer spektralen Verteilung möglichst nach jedem Puls. Im Rahmen dieser Diplomarbeit wurden zwei Spektrometer entwickelt und am DRACO-Lasersystem des Forschungszentrums Dresden implementiert. Neben der Inbetriebnahme eines Thomson-Spektrometers mit einer Mikrokanalplatte und einem Fluoreszenzschirm als Auslese erfolgte die Entwicklung eines Flugzeitspektrometers. Die Verwendung einer Mikrokanalplatte mit nur 180ps Anstiegszeit als Signalverstärker sorgt darin für eine verbesserte Energieauflösung und einen flexibleren Einsatz im Experimentierbetrieb. Ein dem Flugzeitsignal überlagertes Störsignal, welches durch die Einstreuungen eines elektromagnetischen Impulses in den Aufbau verursacht wurde, konnte erfolgreich durch die Anwendung verschiedener Filter unterdrückt werden. Als Ergebnis dieser Arbeit steht eine anwendungsbereite Diagnostik für laserbeschleunigte Protonen und Ionen zur Verfügung. / By focusing an ultra-short high-intensity laser pulse on a solid target, pulses of protons and other positive charged ions with energies of several MeV per nucleon are generated. It is necessary to identify the species of those particles and obtain their energy spectra in a single-shot regime. Within this diploma thesis two spectrometers have been developed and implemented in the DRACO-laboratory of the Forschungszentrum Dresden. Besides a Thomson spectrometer with read-out via microchannel plate and phosphor screen, a time-of-flight spectrometer was developed. The usage of a microchannel plate with 180ps rise time as a signal amplifier leads therein to a better energy resolution and a more flexible handling in experimental operation. A noise signal generated by stray pick-up of an electromagnetic pulse and superimposing the time-of-flight signal was considerably reduced by the application of different filters. As a result of this work a ready-to-use diagnostic for laser accelerated protons and ions is available.

Page generated in 0.3804 seconds