• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 4
  • 1
  • 1
  • Tagged with
  • 46
  • 38
  • 27
  • 22
  • 17
  • 17
  • 17
  • 16
  • 16
  • 16
  • 15
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo do acionamento do motor síncrono de ímãs permanentes: abordagem baseada no controle vetorial com ângulo de torque constante

Sá, Franciéli Lima de 30 July 2010 (has links)
Made available in DSpace on 2016-12-12T17:38:37Z (GMT). No. of bitstreams: 1 FRANCIELI LIMA DE SA.pdf: 957791 bytes, checksum: 54a198d079685e3726016b54e682ffdc (MD5) Previous issue date: 2010-07-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work is introduced a study of Permanent Magnet Synchronous Motor (PMSM), involving issues about constructive characteristics, modeling, control and simulation. Initially, are studied the constructive characteristics, principally in that refers of the magnets disposition in the rotor. Then, are shown some applications for the PMSM. The mathematic model of PMSM is developed starting of stationary reference frame and utilizing the rotation transformation for obtain the equations of currents and voltage in the rotor reference frame. The feed shape of the PMSM is an analysis of extreme importance in the study of this motor, for this reason also is show in this work. The vector control is analyzed in the sequence, utilizing the direct method for the rotor flux and considering the approach with Constant torque control. Are presents some techniques for the design of controllers of speed and current loops. Through the performed simulations, are analyzed and compared the several technical approached. The results obtained show that the vector control approach with constant torque angle applied to the PMSM presents a good dynamic response for motor drive. / Neste trabalho, é apresentado um estudo do Motor Síncrono de Ímãs Permanentes (MSIP) envolvendo questões pertinentes às características construtivas, modelamento, controle e simulação. Inicialmente, são estudadas as características construtivas, principalmente no que se refere à disposição dos ímãs no rotor. Em seguida são mostradas algumas aplicações para o MSIP. O modelo matemático do MSIP é desenvolvido partindo do referencial estacionário e utilizando a transformação de rotação para se obter as equações de corrente e tensão no referencial girante. A forma de alimentação do MSIP é uma análise de extrema importância no estudo deste motor, e por esta razão também é mostrada neste trabalho. O controle vetorial é analisado na seqüência, utilizando o método direto pelo fluxo de rotor e considerando a abordagem com controle de torque constante. São apresentadas algumas técnicas para o projeto dos controladores das malhas de corrente e velocidade. Através das simulações realizadas, são analisadas e comparadas as diversas técnicas abordadas. Os resultados obtidos mostram que o controle vetorial com abordagem do ângulo de torque constante aplicado ao MSIP apresenta uma boa resposta dinâmica para o acionamento do motor.
42

Uma modelagem da máquina síncrona considerando o efeito da curvatura da sapata polar

Alves, Aylton José 15 April 2011 (has links)
This work develops a new mathematical model to the salient pole synchronous machines (SPSM), based on the abc reference system. The model considers the distribution and coil pitch factors of windings and develops a new function for the variable air gap, generated by the curvature of the polar mass. As a result, the development of the modeling takes into account the spatial harmonic components of: magneto motive force MMF(θ)h, electromagnetic ux density B(θ)h and variation function of the air gap g(θ)h. It is also proposed a new and simplied methodology using the locked rotor tests, volt-ampere method, to obtain the constants of the synchronous machine design, which allow the calculation of the modeling parameters and the terminals magnitudes determination. It presents also contributions to traditional methods of obtaining experimental inductances, using the locked rotor test. Yet it develops procedures and makes the simulation of the main temporal magnitudes at the generator terminals connected to the utility grid, electrical torque, speed, voltage and current. The model is validated through the theoretical and experimental confrontation of inductances, and also of the voltages and currents at the generator terminals connected to the utility grid. / Este trabalho desenvolve uma nova modelagem matemática para as máquinas síncronas de polos salientes (MSPS), baseada no sistema abc de referência. A modelagem considera os fatores de distribuição e de passo de bobina dos enrolamentos e desenvolve uma nova função para o entreferro variável, gerado pela curvatura da sapata polar. Como conseqüência o desenvolvimento da modelagem leva em consideração os componentes harmônicos espaciais de: força magneto motriz FMM(θ)h, densidade de uxo eletromagnético B(θ)h e da função de variação do entreferro g(θ)h. É também proposto uma nova e simplificada metodologia a partir dos testes de rotor bloqueado, método volt-ampere, para a obtenção das constantes de projeto da máquina síncrona que possibilitam os cálculos dos parâmetros da modelagem, bem como a determinação das grandezas terminais. Também apresenta contribuições aos métodos tradicionais de obtenção de indutâncias experimentais, a partir dos testes de rotor bloqueado. Ainda desenvolve os procedimentos e faz a simulação das principais grandezas temporais nos terminais do gerador conectado à rede da concessionária: torque elétrico, velocidade, corrente e tensão. A modelagem é convalidada através das confrontações teórico-experimental das indutâncias, e também dos resultados de correntes e tensões nos terminais do gerador conetado à rede da concessionária. / Doutor em Ciências
43

Uma proposta de regulador automático de tensão microcontrolado para geradores síncronos isolados

Alves, Guilherme Henrique 16 September 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os sistemas de controle de excitação em máquinas síncronas devem detectar com bastante rapidez as mudanças causadas pela entrada de carga no gerador isolado e atuar no sistema de excitação de forma rápida e eficiente, para manter a tensão terminal em níveis desejados. Ao contrário de outros trabalhos realizados nesta área com circuitos eletrônicos analógicos, em muitos casos, este controlador pode ser construído utilizando tecnologia microcontrolada por possuir alto nível de eficiência no controle, circuito com flexibilidade para implementação de diferentes estratégias de controle e baixo custo para produção. A abordagem deste trabalho consiste em uma proposta para aplicação de um controle de excitação automático utilizando uma malha PID, com opções de controle manual, monitoramento de tensão terminal e temperatura de estator da máquina, utilizando um microcontrolador PIC16F877A da empresa Microchip Technology. Os resultados obtidos a partir de ensaios práticos em laboratório com partidas diretas de motores de indução (1 e 2 cv) com um gerador de 2 kVA mostra que a atuação do controlador recuperou a tensão terminal em pouco tempo, para o setpoint adotado. E por fim, os resultados obtidos foram comparados com os tempos de resposta de outro conhecido regulador automático de tensão encontrado no mercado, para comprovar o bom desempenho de controle deste projeto. / The excitation control systems in synchronous machines must very quickly detect changes caused by load increase on the isolated generator and act on the excitation system in a rapid and efficient way in order to maintain terminal voltage at optimal desired levels. Unlike other works related with this area which used analog-based electronic circuits, this controller can in many case be built utilizing microcontrolled technology which is more efficient and flexible to implement different control strategies, as well as having a low cost of production. The approach of this research consists in a proposal to apply an automatic excitation controller, utilizing a PID control loop, including manual adjustments and monitorings of terminal voltage and stator temperature of the machine. It employs a PIC16F877A microcontroller from the Microchip Technology Company. The results obtained through practical tests in laboratory with a direct online start of induction motors (1 and 2 HP) on a 2 kVA generator show that the controller acts to recover the terminal voltage to the adopted setpoint in a reduced time. Finally, the results were also compared to the time of response provided from another well-known automatic voltage regulator found in the market, in order to prove the good control performance of this project. / Dissertação (Mestrado)
44

Efeitos da operação do gerador de indução no comportamento do gerador síncrono operando em um sistema isolado alimentando cargas não lineares / Effects of the induction generator operation on the synchronous generator behavior operating on an isolated system feeding nonlinear loads

Oliveira, José Mário Menescal de 13 July 2018 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-09-14T11:19:37Z No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-09-17T10:48:33Z (GMT) No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-09-17T10:48:33Z (GMT). No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-13 / This thesis demonstrates the effects of harmonic pollution in a salient pole synchronous generator and an induction generator operating in parallel on an isolated system, supplying a non-linear load. The main contributions of this research-study consist of identifying and quantifying the oscillations that non-linear load cause on the electric variables of synchronous and induction generators, such as, the electromagnetic conjugate that presents oscillations of sixth harmonic due to the distorted currents. / Este trabalho mostra os efeitos da poluição harmônica em um gerador síncrono de polos salientes e um gerador de indução operando em paralelo em um sistema isolado suprindo carga não linear. As principais contribuições deste trabalho consistem em identificar e quantificar as oscilações que a carga não linear utilizada provoca nas variáveis elétricas dos geradores síncronos e dos geradores de indução, tal como, o conjugado eletromagnético que apresenta oscilações de sexto harmônico devido as correntes distorcidas.
45

Estudo de máquinas elétricas especiais: motor monofásico de pólos inscritos / not available

Cesar Augusto Moreira Amêndola 29 August 2002 (has links)
Este trabalho trata de um estudo teórico sobre o MMPI. Inicialmente, apre-sentamos um levantamento bibliográfico sobre o MMPI evidenciando os seus aspectos construtivos, seu funcionamento, suas características operacionais e suas possíveis aplicações. Em seguida, elaboramos um modelo físico fundamentado nas teorias do Motor de Indução Duplamente Alimentado (MIDA) e do Motor de Histerese (MH), o qual agrega as principais características operacionais do MMPI e reproduz o processo dinâmico de inscrição de pólos na periferia do rotor. A partir deste modelo físico propomos um modelo matemático, baseado na teoria dos circuitos magneticamente acoplados, constituído pelo equacionamento do MIDA, do MH e das fontes de alimentação do estator e do rotor. Deduzimos teoricamente todos os parâmetros necessários para a simulação computacional. Executamos a sua simulação computacional no software Matlab/SimulinkTM, cujos resultados ilustram o comportamento dinâmico das suas tensões, correntes, fluxos e mecânica. Comparando-se os resultados obtidos na simulação computacional com testes laboratoriais executados pelo CE-PEL, concluímos que o modelo matemático proposto e os parâmetros deduzidos podem ser considerados validados. Finalizando, sugerimos um motor monofásico de pólos lisos a imãs permanentes como uma alternativa mais simples do ponto de vista construtivo, porém com características operacionais semelhantes às do MMPI. / This work deals with a theoretical study on Written-PoleTM single-phase motor. Initially, we present the results from the bibliographical research on the Written-PoleTM motor, evidencing its constructional features, operation process, operational characteristics and some possible applications. Afterwards, we elaborate a physical model based in the theories of the doubly fed induction motor and the hysteresis motor, which incorporates the operational characteristic of Written-PoleTM motor and reproduces the written-pole dynamic process. Starting from this physical model we propose a mathematical model, based on the theory of the magnetically coupled circuits, constituted by the set of differential equations deduced from the doubly fed induction motor, the hysteresis motor and the stator and rotor voltage sources. We deduced theoretically all the computational simulation necessary parameters. We perform its computational simulation in the software Matlab/SimulinkTM, whose results illustrate the dynamic behavior of its voltages, currents, fluxes, torques and speed. Comparing the results obtained from the computational simulation with the CEPEL\'s test results, we concluded that the proposed mathematical model and the deduced parameters can be considered validated. Finally, we suggest a permanent-magnet smooth-pole single-phase motor as an alternative to Written-PoleTM motor. This alternative, even being simpler from the constructional point-of-view, presents operational characteristics similar to the Written-PoleTM single-phase motor.
46

Controle de tensão terminal e potência reativa de um grupo motor gerador diesel conectado à rede de distribuição / Terminal voltage control and reactive power of a powerplant diesel generator connected to the distribution network

Rodolpho Vilela Alves Neves 19 March 2013 (has links)
Este trabalho apresenta uma estratégia de controle coordenado para potência reativa e tensão terminal de um grupo moto gerador (GMG) para uso em um sistema de geração distribuída (GD). A partir da construção de uma superfície fuzzy, baseada no comportamento do erro e da derivada do erro de uma malha de controle, foi realizada a sintonia de controladores fuzzy PD+I para potências ativa e reativa e tensão terminal. O controlador coordenado fuzzy PD+I ajusta automaticamente a tensão nos terminais da máquina e a potência reativa fornecidas à rede de distribuição. A estratégia coordenada é dada através de um parâmetro que regula a malha de potência reativa a partir do erro de tensão terminal, priorizando o ajuste da tensão e ponderando a malha de controle de potência reativa. Para avaliar o desempenho do sistema de controle, a GD é conectada a uma rede de distribuição e submetida a eventos como entrada e saída de cargas locais. O conjunto de cargas locais é composto por um motor de indução, uma carga RLC e um retificador trifásico não controlado. Sete cenários foram simulados para avaliar a estratégia de controle em diferentes regimes de operação do GMG. Resultados para tensão terminal, fator de potência e fluxo de potências entre o sistema, as cargas e a rede, ilustram a eficiência da estratégia de controle apresentada. A estratégia de controle coordenado para potência reativa e tensão terminal se mostrou capaz de melhorar os índices de fator de potência controlando o fluxo de potência do barramento em que a GD estava conectada, sem prejudicar a tensão terminal do gerador, mantendo a GD em limites seguros de operação. / This work presents a coordinated control strategy to terminal voltage and reactive power for a diesel generation set used as a distributed gerenation system (DG). From desired control actions, a fuzzy surface was designed for fuzzy PD+I controllers. Fuzzy PD+I controllers automatically adjust the terminal voltage and the reactive power delivered to the grid. The coordinated control strategy weighs the control action for the reactive power through a variable parameter, prioritizing the terminal voltage adjustment. To illustrate the system control performance, the DG is connected to a grid dynamic model and the system is subjected to connection and disconnection of loads at the local bus. The local loads set was composed of an induction machine, a RLC load and an uncontrolled three-phase rectifier. Seven scenarios were simulated to evaluate the control strategy in different DG regime of operation. Results for terminal voltage, power factor and reactive power among the DG, the local loads and the grid, illustrates the control strategy efficiency improved the power factor by regulating the reactive power injected at the bus, maintaining the DG terminal voltage in safe operation limits.

Page generated in 0.1576 seconds