• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 14
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 50
  • 50
  • 28
  • 14
  • 13
  • 13
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Nitrogen Doping of Electrochemically Activated Carbon Screen Printed Electrodes

Galloway, Ethaniel L, Bishop, Gregory W, Ph.D. 06 April 2022 (has links)
Screen printed electrodes (SPEs), which are prepared by patterning conductive inks or pastes onto an insulating support (e.g., plastic film), are widely employed as sensing and biosensing platforms due to their ease of fabrication and relatively low cost. This is especially applicable to electrodes of this nature prepared with carbon-based inks (SPCEs). To date, the most successful and significant commercial application of SPEs has been as test strips for glucose meters. Despite the maturity of this technology, SPE research remains very active as improvements in sensitivity and selectivity, which often involve modifying the electrode surface, hold the key to advancing their utility in routine applications and extending their benefits to other target analytes. Recent studies in the Bishop research group have demonstrated that nitrogen-doped SPCEs (N-SPCEs) exhibit enhanced electrochemical response towards hydrogen peroxide (H2O2), a product of oxidase enzyme (e.g., glucose oxidase, lactate oxidase, etc.) reactions and a common target in biosensing strategies. The presence of nitrogen heteroatoms on the carbon surface facilitates breakage of oxygen-oxygen bonds, a key step in reduction of H2O2. Since previous studies showed only modest incorporation of nitrogen species on SPCEs prepared from commercial ink, these studies aim to investigate the possibility of enhancing N-doping by performing a simple pre-treatment strategy that reportedly increases surface oxygen content of SPCEs prior to N-doping. Since surface oxygen sites have been previously reported to be preferentially modified with nitrogen during N-doping strategies, this seems like a promising technique for improving sensitivity of N-SPCEs for H2O2 reduction. To quantify the actuality of these claims, experimental groups were fabricated having undergone no enhancement, pretreatment enhancement only, nitrogen-doping enhancement only, and a combination of the pretreatment and nitrogen-doping enhancements. Here the electrochemical behaviors of pretreated SPCEs, N-SPCEs, and pretreated N-SPCEs for the detection of H2O2 by completing comparative cyclic voltammetry (CV) experiments with and with out the presence of H2O2 and with it present in varying concentrations is compared. It is projected that, if successful, the fabricated electrodes that have undergone both the pretreatment protocol and the nitrogen-doping process will have an increased sensitivity and detection limit towards H2O2.
22

Peroxide Sensing Using Nitrogen-Doped and Platinum Nanoparticle-modified Screen-Printed Carbon Electrodes

Ogbu, Chidiebere 01 August 2019 (has links)
Nitrogen-doped carbon materials have garnered much interest due to their abilities to behave as electrocatalysts for reactions important in energy production (oxygen reduction) and biosensing (hydrogen peroxide reduction). Here, we demonstrate fabrication methods and determine electrocatalytic properties of nitrogen-doped screen-printed carbon (N-SPCE) electrodes. Nitrogen doping of graphite was achieved through a simple soft-nitriding technique which was then used in lab-formulated screen-printing inks to prepare N-SPCEs. N-SPCEs displayed good electrocatalytic activity, reproducibility and long term stability towards the electrochemical reduction of hydrogen peroxide. N-SPCEs exhibited a wide linear range (20 µM to 5.3 mM), reasonable limit of detection of 2.5 µM, with an applied potential of -0.4 V (vs. Ag/AgCl). We also demonstrate that nitrided-graphite can similarly be used as a platform for the deposition of electrocatalytic platinum nanoparticles, resulting in Pt-N-SPCEs with a lower limit of detection (0.4 µM) and better sensitivity (0.52 µA cm-2 µM-1) towards H2O2 reduction.
23

CYCLIC VOLTAMMETRIC DETERMINATION OF 17-α-ETHINYL ESTRADIOL ON DISPOSABLE SCREEN-PRINTED CARBON ELECTRODES

Qian, Zepeng 12 August 2019 (has links)
No description available.
24

Desenvolvimento de um biossensor mimético descartável para pesticidas organofosforados e carbamatos para o controle de qualidade de águas de abastecimento / Development of a disposable mimetic biosensor for organophosphorus and carbamate pesticides aiming quality control of water supply

Lívia Flório Sgobbi 26 February 2016 (has links)
A enzima acetilcolinesterase (AChE) tem sido amplamente aplicada no desenvolvimento de biossensores para detecção de pesticidas. No entanto, a aplicação de tais dispositivos é limitada devido à falta de robustez, que está associada com a baixa estabilidade enzimática, além de seu alto custo. Uma alternativa às enzimas é a utilização de moléculas sintéticas que mimetizem o comportamento enzimático, com menor custo e maior estabilidade; tais moléculas são denominadas moléculas biomiméticas. Neste trabalho são apresentados três potenciais catalisadores: o ácido [4-(1E)etanohidrazonoil]benzóico, o iodeto de pralidoxima (2-PAM) e o polímero polihidroxamicalcanoato (PHA); com grupos funcionais alfa nucleófilos hidrazona, oxima e ácido hidroxâmico, respectivamente. Tais moléculas foram avaliadas baseando-se em dois critérios para classificação de biomiméticos da AChE: 1) catálise da hidrólise do substrato acetiltiocolina (ATCh) e 2) interação com pesticida organofosforado. O método espectrofotométrico de Ellman revelou que o polímero PHA foi a molécula mais eficiente, uma vez que a constante de velocidade de segunda ordem obtida foi de 13867 mol-1 L s-1, 5 vezes superior a da 2-PAM e 232 vezes a da hidrazona. Posteriormente, todas as moléculas foram avaliadas por método espectrofotométrico em relação à interação com o organofosforado paraoxon. Apenas o PHA apresentou interação nas condições estudadas. Cálculos teóricos mostraram como ocorre a aproximação entre o PHA e ATCh, e com o paraoxon. Diante dos resultados obtidos, o PHA foi a molécula biomimética escolhida para aplicação no sensor eletroquímico para detecção de organofosforados. Primeiramente, o PHA foi imobilizado na superfície de um eletrodo impresso descartável a partir da formação de uma blenda com o polímero polietileno glicol metil éter, evitando sua solubilização. A oxidação da tiocolina formada a partir da catálise do ATCh realizada pelo PHA imobilizado foi verificada em 0,46 V vs Ag/AgCl, por voltametria de pulso diferencial. A equação obtida a partir da curva de calibração referente ao intervalo de concentração de paraoxon de 1,0 a 10,0 µmol L-1 foi I(%) = [4,8x106 C (mol L-1) + 0,8169]×100 (R2 = 0,99969), com limite de detecção de 3,63x10-7 mol L-1. Amostras de água de abastecimento foram analisadas, com concentrações adicionadas de paraoxon de 3,0; 6,0 e 8,0 µmol L-1, com recuperação de 115%; 106% e 94,5%, respectivamente. Os resultados apresentados mostraram que foi possível desenvolver um sensor eletroquímico biomimético para detecção de pesticida paraoxon. / Acetylcholinesterase enzyme (AChE) has been widely applied in biosensor development for pesticide detection. However, the application of those biosensors is limited due to their lack of robustness associated with low enzymatic stability and AChE high cost. An alternative to enzymes, it is the use of synthetic molecules which mimic enzymatic behavior, besides its low cost and superior stability, those are classified as biomimetic molecules. In this work is presented three potential catalysts: [4-(1E)ethanehydrazonoyl]benzoic acid, pralidoxime iodide (2-PAM), and polyhydroxamicalkalnoate polymer (PHA) with alpha nucleophile functional groups, such as hydrazone, oxime, and hydroxamic acid, respectively. The aforementioned molecules were evaluated based on two criteria for classification as AChE biomimetic: 1) catalysis of acetylthiocholine substrate (ATCh) hydrolysis and 2) interaction with organophosphorus pesticide. Spectrophotometrical Ellman´s method revealed that PHA polymer was the most efficient one, since its second order rate constant was 13867 mol-1 L s-1, which was 5 times superior than 2-PAM one and 232 times higher than hydrazone. Then, each molecule was analyzed through spectrophotometric method to verify the interaction with paraoxon organophosphorus pesticide. Only the PHA exhibited such interaction in the studied conditions. Theoretical calculations showed how the approach between PHA and ATCh, and also with paraoxon occurred. Regarding the obtained results, PHA was the chosen biomimetic molecule to be applied in the electrochemical sensor for organophosphorus detection. First of all, PHA was immobilized on the surface of disposable screen printed electrode through blend formation with polyethylene glycol methyl ether (mpEG), avoiding PHA dissolution. The oxidation of thiocholine generated towards ATCh catalysis performed by immobilized PHA was verified at 0.46 V vs Ag/AgCl by differential pulse voltammetry. The linear equation obtained through calibration curve for paraoxon concentration range of 1.0 to 10.0 µmol L-1 was I(%) = [4.8x106 C (mol L-1) + 0.8169]×100 (R2 = 0.99969), with limit of detection of 3.63x10-7 mol L-1. Water supply samples were analyzed considering the added paraoxon concentrations of 3.0; 6.0 e 8.0 µmol L-1, recovering 115%; 106% and 94.5%, respectively. The presented results showed that a biomimetic electrochemical sensor was successfully developed for detection of paraoxon organophosphorus pesticide.
25

Desenvolvimento de um biossensor mimético descartável para pesticidas organofosforados e carbamatos para o controle de qualidade de águas de abastecimento / Development of a disposable mimetic biosensor for organophosphorus and carbamate pesticides aiming quality control of water supply

Sgobbi, Lívia Flório 26 February 2016 (has links)
A enzima acetilcolinesterase (AChE) tem sido amplamente aplicada no desenvolvimento de biossensores para detecção de pesticidas. No entanto, a aplicação de tais dispositivos é limitada devido à falta de robustez, que está associada com a baixa estabilidade enzimática, além de seu alto custo. Uma alternativa às enzimas é a utilização de moléculas sintéticas que mimetizem o comportamento enzimático, com menor custo e maior estabilidade; tais moléculas são denominadas moléculas biomiméticas. Neste trabalho são apresentados três potenciais catalisadores: o ácido [4-(1E)etanohidrazonoil]benzóico, o iodeto de pralidoxima (2-PAM) e o polímero polihidroxamicalcanoato (PHA); com grupos funcionais alfa nucleófilos hidrazona, oxima e ácido hidroxâmico, respectivamente. Tais moléculas foram avaliadas baseando-se em dois critérios para classificação de biomiméticos da AChE: 1) catálise da hidrólise do substrato acetiltiocolina (ATCh) e 2) interação com pesticida organofosforado. O método espectrofotométrico de Ellman revelou que o polímero PHA foi a molécula mais eficiente, uma vez que a constante de velocidade de segunda ordem obtida foi de 13867 mol-1 L s-1, 5 vezes superior a da 2-PAM e 232 vezes a da hidrazona. Posteriormente, todas as moléculas foram avaliadas por método espectrofotométrico em relação à interação com o organofosforado paraoxon. Apenas o PHA apresentou interação nas condições estudadas. Cálculos teóricos mostraram como ocorre a aproximação entre o PHA e ATCh, e com o paraoxon. Diante dos resultados obtidos, o PHA foi a molécula biomimética escolhida para aplicação no sensor eletroquímico para detecção de organofosforados. Primeiramente, o PHA foi imobilizado na superfície de um eletrodo impresso descartável a partir da formação de uma blenda com o polímero polietileno glicol metil éter, evitando sua solubilização. A oxidação da tiocolina formada a partir da catálise do ATCh realizada pelo PHA imobilizado foi verificada em 0,46 V vs Ag/AgCl, por voltametria de pulso diferencial. A equação obtida a partir da curva de calibração referente ao intervalo de concentração de paraoxon de 1,0 a 10,0 µmol L-1 foi I(%) = [4,8x106 C (mol L-1) + 0,8169]×100 (R2 = 0,99969), com limite de detecção de 3,63x10-7 mol L-1. Amostras de água de abastecimento foram analisadas, com concentrações adicionadas de paraoxon de 3,0; 6,0 e 8,0 µmol L-1, com recuperação de 115%; 106% e 94,5%, respectivamente. Os resultados apresentados mostraram que foi possível desenvolver um sensor eletroquímico biomimético para detecção de pesticida paraoxon. / Acetylcholinesterase enzyme (AChE) has been widely applied in biosensor development for pesticide detection. However, the application of those biosensors is limited due to their lack of robustness associated with low enzymatic stability and AChE high cost. An alternative to enzymes, it is the use of synthetic molecules which mimic enzymatic behavior, besides its low cost and superior stability, those are classified as biomimetic molecules. In this work is presented three potential catalysts: [4-(1E)ethanehydrazonoyl]benzoic acid, pralidoxime iodide (2-PAM), and polyhydroxamicalkalnoate polymer (PHA) with alpha nucleophile functional groups, such as hydrazone, oxime, and hydroxamic acid, respectively. The aforementioned molecules were evaluated based on two criteria for classification as AChE biomimetic: 1) catalysis of acetylthiocholine substrate (ATCh) hydrolysis and 2) interaction with organophosphorus pesticide. Spectrophotometrical Ellman´s method revealed that PHA polymer was the most efficient one, since its second order rate constant was 13867 mol-1 L s-1, which was 5 times superior than 2-PAM one and 232 times higher than hydrazone. Then, each molecule was analyzed through spectrophotometric method to verify the interaction with paraoxon organophosphorus pesticide. Only the PHA exhibited such interaction in the studied conditions. Theoretical calculations showed how the approach between PHA and ATCh, and also with paraoxon occurred. Regarding the obtained results, PHA was the chosen biomimetic molecule to be applied in the electrochemical sensor for organophosphorus detection. First of all, PHA was immobilized on the surface of disposable screen printed electrode through blend formation with polyethylene glycol methyl ether (mpEG), avoiding PHA dissolution. The oxidation of thiocholine generated towards ATCh catalysis performed by immobilized PHA was verified at 0.46 V vs Ag/AgCl by differential pulse voltammetry. The linear equation obtained through calibration curve for paraoxon concentration range of 1.0 to 10.0 µmol L-1 was I(%) = [4.8x106 C (mol L-1) + 0.8169]×100 (R2 = 0.99969), with limit of detection of 3.63x10-7 mol L-1. Water supply samples were analyzed considering the added paraoxon concentrations of 3.0; 6.0 e 8.0 µmol L-1, recovering 115%; 106% and 94.5%, respectively. The presented results showed that a biomimetic electrochemical sensor was successfully developed for detection of paraoxon organophosphorus pesticide.
26

Filme condutor obtido eletroquimicamente à partir do Cloridrato de Amiodarona

Araujo, Tatiana da Silva January 2016 (has links)
Orientador: Prof. Dr. Hugo Barbosa Suffredini / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Ciência e Tecnologia/Química, 2016. / O objetivo deste trabalho foi o de apresentar um novo material com característica condutora, obtido a partir da eletrooxidação do fármaco cloridrato de amiodarona. Foram utilizados o eletrodo de carbono impresso, eletrodo de platina, carbono vítreo e diamante dopado com boro (DDB) e a técnica de voltametria cíclica para a deposição do material. O material depositado foi caracterizado aplicando-se a técnica de Microscopia Eletrônica de Varredura (MEV) que possibilitou a visualização do material depositado nos diferentes materiais dos eletrodos. Com o uso da Espectroscopia de Energia Dispersiva (EDS), obteve-se uma análise química qualitativa do filme aderido ao eletrodo de carbono impresso, que indicou a presença de átomos de iodo, elemento presente na molécula de cloridrato de amiodarona, confirmando a deposição do fármaco estudado. A análise por UV-vis também confirmou a adesão do material, quando dissolvido em N-metil-2-Pirrolidona. Análises de ângulo de contato indicaram o caráter mais hidrofílico do material, quando comparado com o substrato não modificado. Finalmente, pôde-se concluir que ocorreu a formação de um filme condutor oriundo da molécula de cloridrato de amiodarona. / The aim of this work was to synthesize a new conductive material from the drug amiodarone hydrochloride. Several carbonaceous materials were used as substrate, as glassy carbon, boron-doped diamond and screen-printed carbon electrode. Platinum electrodes were also used with the same purpose. All synthesized materials were characterized by Scanning Electron Microscopy (SEM), which enabled the visualization of the modifications for all studied materials. Energy Dispersive Spectroscopy (EDS) were used to promote the qualitative analysis of the samples, indicating the presence of iodine atoms, an element present in the original amiodarone molecule. UV-vis spectroscopy also confirmed the adhesion of the material. Contact angle analysis indicates that the modification has the surface more hydrophobic than the pristine material. Finally, it was possible to conclude that a conductor film from amiodarone hydrochloride was adequately synthesized in all studied substrates.
27

Desenvolvimento de plataformas sensoras para detecção eletroquímica do antígeno NS1 do vírus da dengue

DIAS, Ana Carolina Matos da Silva 06 May 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-07-14T14:18:26Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese de Doutorado - Ana Carolina M.S. Dias.pdf: 7391913 bytes, checksum: 55ab68bd39f956f754684f4b795a7baa (MD5) / Made available in DSpace on 2016-07-14T14:18:27Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese de Doutorado - Ana Carolina M.S. Dias.pdf: 7391913 bytes, checksum: 55ab68bd39f956f754684f4b795a7baa (MD5) Previous issue date: 2015-05-06 / FACEPE / A infecção pelo vírus dengue (DENV) é uma das doenças tropicais mais negligenciadas e de maior importância de saúde pública no mundo. Novos métodos de diagnóstico da doença têm sido estudados através da detecção da proteína NS1 do DENV. O antígeno NS1 é um importante marcador precoce da fase aguda da dengue, secretado em altas concentrações pelo vírus no sangue de pessoas infectadas logo nos primeiros dias, porém, não é muito utilizado na rotina laboratorial para diagnóstico da doença devido ao alto custo dos ensaios. A presente tese descreve o desenvolvimento de duas plataformas sensoras eletroquímicas baseadas em eletrodos impressos (EIs) modificados com nanomateriais para detecção do antígeno NS1 do DENV. Os EIs foram confeccionados utilizando-se a impressão de tinta de carbono sobre o polietileno tereftalato (PET), suporte para impressão dos moldes. Inicialmente, foram estudados os efeitos de nanotubos de carbono e sua contribuição na transferência de elétrons, condutividade e aumento de área eletroativa da plataforma sensora. O estudo foi baseado na incorporação de nanotubos de carbono funcionalizados com grupos carboxílicos à tinta de carbono. Para detecção do NS1, um imunoensaio do tipo “sanduíche” foi realizado, no qual a captura específica do NS1 pôde ser avaliada através das reações redox da enzima peroxidase conjugada ao anticorpo. Uma faixa linear entre 0,04 g/mL e 2 g/mL de NS1 foi obtida, indicando boa performance analítica do imunossensor, com coeficiente de correlação linear de 0,996 (p<0.0001, n=8) e limite de detecção de 0,012 g/mL de NS1. Posteriormente, foi investigada a contribuição de nanopartículas metálicas no desenvolvimento de sensores eletroquímicos livres de marcação. Foram utilizadas nanopartículas de ouro (NPsAu) funcionalizadas com grupos amina para a imobilização covalente de anticorpos. Na síntese das NPsAu, foi utilizado o polietilenoimina como agente redutor e funcionalizante para promover uma ligação amida com o anticorpo anti-NS1. O imunossensor desenvolvido mostrou curva de calibração com faixa de concentração linear entre 0,1 g/mL e 2 g/mL de NS1 (r = 0,995, p<0.0001, n=7) e limite de detecção de 0,03 g/mL de NS1. A contribuição dos nanomateriais para as plataformas sensoras desenvolvidas mostrou-se efetiva na sensibilidade analítica, devido ao aumento de área eletroativa e maior quantidade de anticorpos imobilizados. A aplicação destes nanomateriais nos imunossensores proporciona novas alternativas de diagnóstico para detecção da proteína NS1 do DENV. / Infection by Dengue Virus (DENV) is one of the most neglected tropical diseases and of higher importance of public health worldwide. New methods of diagnosis of the disease have been studied through the detection of NS1 protein of DENV. NS1 antigen is an important early marker of acute dengue infection secreted in high concentrations by the virus in the blood of infected people in first days, however it is not widely used in the laboratory routine for diagnosis of the disease due to high cost of assays. The present thesis describes the development of two electrochemical sensor platforms based on screen-printed electrodes (SPEs) modified with nanomaterials for detection of NS1 antigen of DENV. SPEs were prepared using carbon ink printing on the polyethylene terephthalate (PET), support for molds printing. Initially, the effects of carbon nanotubes and their contribution to the electron transfer, conductivity and increase of electroactive area of the sensor platform were studied. The study was based on the incorporation of carbon nanotubes functionalized with carboxylic groups to the carbon ink. For NS1 detection, a sandwich-type immunoassay was carried out, wherein the specific capture of NS1 may be assessed by redox reactions of peroxidase enzyme conjugated to the antibody. A linear range between 0.04 g/mL and 2 g/mL NS1 was obtained, indicating good analytical performance of the immunosensor, with linear correlation coefficient of 0.996 (p<0.0001, n=8) and limit of detection of 0.012 g/mL NS1. Subsequently, the contribution of metal nanoparticles in the development of label-free electrochemical sensors was investigated. Gold nanoparticles (AuNPs) functionalized with amine groups were used for covalent immobilization of antibodies. In the synthesis of AuNPs, polyethyleneimine was used as a reducing and functionalizing agent to promote an amide bond with anti-NS1 antibody. The developed immunosensor showed calibration curve with linear concentration range between 0.1 g/mL and 2 g/mL NS1 (r = 0.995, p<0.0001, n = 7) and limit of detection of 0.03 g/mL NS1. The contribution of nanomaterials for the sensor platforms developed proved effective in the analytical sensitivity due to the increase of electroactive area and larger amount of immobilized biomolecules. The application of these nanomaterials in immunosensors provides new alternatives of diagnosis for detection of NS1 protein of DENV.
28

Vliv způsobu předúpravy tištěných uhlíkových elektrod na jejich elektrochemické chování / Effect of pretreatment methods on electrochemical behavior of screen-printed carbon electrodes

Weiss, Vojtěch January 2017 (has links)
The aim of this work is the thick-film electrochemical sensor characterization. In the theoretical part, the thesis describes sensor, three-electrode system, characterization electrode using cyclic voltammetry and electrode pretreatment methods. The experimental part compares the results of cyclic voltammetry of bare carbon electrodes, chemically pre-treated electrodes, electrochemically pre-treated electrodes and electrodes modified by plasma oxidation.
29

Desenvolvimento e aplicação de eletrodos compósitos impressos à base de grafite e poliuretana / Development and application of graphite and polyurethane screen-printed composite electrodes

Saciloto, Thalita Rocha 07 November 2014 (has links)
Um método de fabricação para eletrodos compósitos impressos à base de grafite e resina poliuretana (EIGPU) foi desenvolvido, iniciando-se pela tinta e processo para a impressão, além da otimização dos parâmetros para garantir a aplicabilidade e maximização da resposta dos mesmos. Os parâmetros otimizados na fabricação da tinta foram a composição de 60% grafite e 40% poliuretana (m/m), a natureza e quantidade de solvente, dimensão do conjunto impresso, quantidade de demãos aplicadas no processo de \"screen-printing\", espessura da máscara adesiva e o tipo de isolante que define os contatos elétricos e a área ativa do eletrodo. Também foi proposto e desenvolvido um procedimento de ativação da superfície do eletrodo, que consiste em uma compressão do compósito, seguido de tratamento eletroquímico da superfície do eletrodo de trabalho, que se mostraram fundamentais para o desempenho adequado do sensor. Os resultados desses estudos inciais foram avaliados usando K3[Fe(CN)6], como sonda eletroquímica. Em seguida, o EIGPU foi avaliado quanto ao seu potencial para determinação de analitos de interesse farmacológico, usando como modelo o paracetamola (APAP) e suas misturasb com cafeína (CAF) em amostras de fármacos (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1); ambiental: Zn2+, Pb2+, Cu2+ e Hg2+ simultaneamente em amostras de etanol combustível (LOD=300, 65, 30, 46 nmol L-1, respectivamente) e biológico: epinefrina (EP) em amostras artificiais de fluido cérebro-espinal sintético (LOD=42,8 e 768 nmol L-1, para DPV e SWV, respectivamente). Para isso, foram usadas Voltametria Cíclica (CV), Voltametria de Pulso Diferencial (DPV), Voltametria de Pulso Diferencial de Redissolução Anódica (DPASV) e Voltametria de Onda Quadrada (SWV). Na determinação dos analitos de interesse ambiental, os eletrodos impressos foram modificados com sílica SBA-15, antes e após organofuncionalização com a espécie benzotiazol-2-tiol. Os compósitos modificados foram preparados substituindo quantidades correspondentes de pó de grafite de modo a obter eletrodos com 5% (m/m) do modificador. Antes de realizar as análises, foram feitas as otimizações dos parâmetros envolvidos em cada técnica escolhida e obtidas as curvas analíticas. Em seguida, o EIGPU foi utilizado na determinação dos analitos nas respectivas matrizes. A quantidade dos analitos presentes nas amostras foi determinada pelo método de adição de padrão, em triplicata. Os resultados foram comparados com aqueles obtidos por Cromatografia Líquida de Alta Eficiência (HPLC) e Espectroscopia de Absorção Atômica (AAS), para as análises farmacêuticas e ambientais, respectivamente. / A method for the fabrication of a graphite polyurethane composite based screen printed electrodes (EIGPU) was proposed by developing a ink and a imprinting procedure after optimizing parameters such as ink composition 60% graphite and 40% polyurethane (m/m), nature and quantity of solvent, dimensions of the electrode set, number of ink layers, deepness of the adhesive mask and nature of the insulating that defines the active electrode area and the electrical contacts. Procedures for activating the electrode surface, by mechanically compressing the ink followed by an electrochemical treatment of the surface were also developed. The results of this phase were evaluated using K3[Fe(CN)6] as an electrochemical probe. Than the EIGPU was evaluated regarding its potentialities for the determination of analytes with pharmacological interest using paracetamola (APAP) and its mixturesb with caffeine (CAF) in pharmaceutical formulations (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1), environmental relevance as metal ions Zn2+, Pb2+, Cu2+ e Hg2+ determined simultaneously in ethanol fuel samples (LOD=300, 65, 30, 46 nmol L-1, respectively) and biologically important as epinephrine (EP) contained in artificial cerebro-spinal fluid. (LOD=42,8 e 768 nmol L-1, for DPV e SWV, respectively).These applications were achieved by means of Cyclic Voltammetry (CV), Differential Pulse Voltammetry (DPV), Square Wave Voltammetry (SWV) and Differential Pulse Anodic Stripping Voltammetry (DPASV). In the determination of the metal ions in ethanol fuel, the electrodes were modified with SBA-15 silica organofunctionalized with benzothiazol-2-thiol. The composities were prepared by substituting corresponding amounts of graphite powder in order to have 5% (m/m) of the modifier in the final device. Before performing the analysis several parameters were optimized for each case for each technique before measuring the analytical curves. After, the EIGPU was used in the determination of the different analytes in the chosen matrices. The amount of analytes present in the samples was determined using addition method in triplicate. The results were compared with those obtained using high performance liquid chromatography (HPLC) and Atomic Absorption Spectrocopy (AAS), as comparision methods.
30

Desenvolvimento de dispositivos eletroquímicos baseados em papel para monitoramento não invasivo de lactato em suor / Development of wearable electrochemical paper-based devices for noninvasive monitoring of lactate in sweat

Gomes, Nathalia Oezau 22 February 2019 (has links)
O lactato é um metabólito chave formado pelo metabolismo anaeróbico da glicose nos músculos, e tem se tornado um biomarcador importante no âmbito clínico e esportivo. Atualmente, existem biossensores eletroquímicos portáteis que são capazes de determinar os níveis de lactato no organismo em tempo real. No entanto, tal método é invasivo uma vez que requer amostras de sangue. O presente projeto tem como objetivo desenvolver um biossensor eletroquímico descartável para detecção de lactato no suor. Para isto a configuração do dispositivo foi feita utilizando a celulose bacteriana como substrato para obtenção de um dispositivo que seja resistente à deformação mecânica, especialmente quando molhado e, também, permeável ao suor. A impressão dos eletrodos de carbono neste substrato foi efetuada utilizando o processo de serigrafia. Com os dispositivos produzidos foram realizados experimentos de voltametria cíclica e espectroscopia de impedância eletroquímica, a fim de caracterizar o sensor desenvolvido e investigar a influência do pré-tratamento eletroquímico na sua performance analítica. A partir da modificação da superfície eletródica com nanocubos de Azul da Prússia foi possível desenvolver um sensor eletroquímico para detecção de peróxido de hidrogênio. A cronoamperometria foi utilizada para a determinação da curva analítica para o peróxido de hidrogênio. Com todos os parâmetros da cronoamperometria otimizados, uma dependência linear da corrente catódica com a concentração de peróxido de hidrogênio foi obtida, com a equação: Ip = 0,1 + 4,30 [H2O2], com r2 = 0,999 (n = 3). Esta curva analítica mostrou que a metodologia apresenta um Limite de Detecção e de Quantificação de mol L-1 e mol L-1, respectivamente. Para a configuração do biossensor eletroquímico a enzima lactato oxidase foi incorporada à superfície do papel pelo método de ligação covalente. Adotando esta metodologia foi verificado um aumento da área eletroativa que possibilitou uma melhora significativa no desempenho do sensor desenvolvido. No qual se obteve uma região linear de 1-24,0 mmol L-1 em suor sintético, obtendo-se Limites de detecção e Quantificação de e mol L-1. Tais parâmetros se mostraram adequados já que o suor pode apresentar níveis de aproximadamente 25 mmol L-1 de lactato. De modo geral, foi possível desenvolver uma plataforma eletroquímica no substrato de celulose bacteriana para a detecção de lactato em amostras de suor sintético. O dispositivo desenvolvido apresentou uma boa durabilidade e resistência ao se executarem sucessivas medidas corroborando a viabilidade deste substrato na projeção de sensores vestíveis para a aplicação direta na pele e monitoramento dos níveis de lactato em tempo real. / Lactate is a key metabolite formed in the anaerobic metabolism of glucose in the muscles. It has become an important biomarker in the clinical and sport scopes. Currently, there are portable biosensors that are able to determine lactate levels in real time. However, these methods are invasive since they require blood samples. Herein, we aim to develop a disposable wearable electrochemical biosensor for detection of lactate in sweat. For this purpose the configuration of the device was made with bacterial cellulose substrate in order to be permeable to sweat and resistant to mechanical deformation, especially when wet. The fabrication of the electrodes was made through screen printing technique. Electrochemical impedance spectroscopy and cyclic voltammetry were used to characterize the sensor developed in order to investigate the influence of the electrochemical pre-treatment in the analytical performance of the electrodes. To develop an electrochemical sensor for the detection of hydrogen peroxide the screen printed electrode was modified with Prussian blue nanocubes. Chronoamperometry experiments were used to detect of hydrogen peroxide. From optimized chronoamperometry parameters, a linear dependence of the cathodic current with the hydrogen peroxide concentration was obtained with the equation: Ip = 0.1 + 4.30 [H2O2], with r2 = 0.999 (n = 3). The limit of detection (LOD) and the limit of quantification (LOQ) were mol L-1 e mol L-1, respectively. For the configuration of the electrochemical biosensor the lactate oxidase enzyme was immobilized on the paper surface by the covalent bonding method. Adopting this methodology was verified an increase of the electroactive area that allowed a significant improvement in the performance of the developed sensor. In which a linear concentration range of 1-24.0 mmol L-1 was obtained in the synthetic sweat, obtaining LOD and LOQ of mol L-1 e mol L-1, respectively. Such parameters were adequate since sweat may have lactate levels of approximately 25 mmol L-1. Finally, it was possible to develop an electrochemical platform using the bacterial cellulose substrate for the detection of lactate in samples of synthetic sweat. The developed device presented a good durability and resistance when performing electrochemical measurements assuring the feasibility of this substrate in the projection of wearable sensors for the direct application to skin and monitoring of lactate levels in real time.

Page generated in 0.0629 seconds