• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um potenciostato/galvanostato portátil e eletrodos impressos para determinações in situ em análises em fluxo com transmissão de dados em tempo real / Development of a portable potentiostat/galvanostat and screen-printed electrodes for in situ determinations in flow analysis with data transmission in real time

Santos, Vagner Bezerra dos 19 July 2013 (has links)
Made available in DSpace on 2016-06-02T20:34:45Z (GMT). No. of bitstreams: 1 5296.pdf: 9754630 bytes, checksum: 1116c7f7ac323deb5c484942710d0111 (MD5) Previous issue date: 2013-07-19 / Financiadora de Estudos e Projetos / The main purpose of this work was to develop a potentiostat/galvanostat (PG004) to perform the electroactive metallic ions determination in water samples automatically. A dry thermostated electrochemical cell and a flow system with multicommutation were developed based on the use of the solenoid micropumps and valves with screen-printed electrodes (SPE) for the electrochemical measurements with detection employing stopped flow or continuous flow techniques. Two types of the SPE were developed: i) the SPE based on bismuth film (SPE-BiF) electrochemically deposited for on-line and in situ or ex situ modes, and ii) the boron doped diamond coupled to the SPE (SPE-BDD). These devices, and the electrodes were optimized and their performances were evaluated firstly by employing commercially available potentiostat/galvanostat. Thus, individual or simultaneous determination of Zn2+, Cd2+, and Pb2+ ions were carried out using the stopped flow technique and detection employing square-wave anodic stripping voltammetry (SWASV) to the SPE-BiF, and differential pulse (DPASV) for the SPE-BDD. Limits of detection (LDs) of 1.60 μg L-1, 0.30 μg L-1 and 0.09 μg mL-1, respectively were obtained for the simultaneous determination of Zn2+, Cd2+, and Pb2+ ions by using the SPE BiF ex-situ with SWASV. For the BDD-SPE-DPASV, LDs of 2.50 μg L-1, 0.38 μg L-1 and 0.10 μg L-1 were obtained, respectively, for the determination mentioned previously. Determination of analytes individually or simultaneously were also carried out with SPE-BDD employing multiple pulse amperometry (MPA), and LDs of 150 μg L-1, 87.0 μg L-1 and 13.0 μg mL-1 were obtained respectively for simultaneous determination of Zn2+, Cd2+, and Pb2+ ions with a sampling rate of 54 determinations per hour. In parallel with the electroanalyticals determinations, the PG004 was developed according to the following sequence. i) development of the electronic circuits; ii) calibrations of the PG004; iii) assembly of the PG004 with the flow module coupled to it; iv) coupling of the peripheral devices to the CPU of the PG004 for the wireless transmission of the data with Bluetooth®, Wi-Fi® and 3G protocol, and a GPS receiver), and v) connections of the power unit (12 V batteries) and solar board. Then, the PG004 was employed to determine Cd2+ and Pb2+ ions with SPE-BDD and SWASV in laboratory to simulate in situ conditions. Then, the PG004 was placed to the field for in situ determinations of Cd2+ and Pb2+ ions with good results: i) individual and simultaneous determinations of the Cd2+ and Pb2+ ions with recoveries ranged from 93.3 to 109%; ii) voltammograms with no noises and with good resolutions; iii) reception of the geographical coordinates using the GPS receiver and sending experimental data via mobile technology (GPRS); iv) great autonomy of energy due to the solar board; v) automated capture, filtration and thermostatic temperature control for in situ analysis; vi) SPE-BDD and SPE-BiF reusable at the end of the analysis and vii) low waste generation per determination (700 μL). / O objetivo central deste trabalho foi desenvolver um potenciostato/galvanostato (PG004) para aplicação na determinação de íons metálicos eletroativos em amostras de águas naturais de modo automatizado. Foram também desenvolvidos uma célula eletroquímica termostatizada a seco e sistemas em fluxo com multicomutação baseado no emprego de microbombas, válvulas solenoide e eletrodos impressos para determinações eletroquímicas com detecção com parada de fluxo ou com detecção com fluxo contínuo. Os eletrodos foram de dois tipos: i) eletrodos impressos de filme de bismuto (SPE-BiF) depositados eletroquimicamente em modo online e in situ ou ex situ; ii) diamante dopado com boro acoplado a eletrodo impresso (SPE-BDD). Estes aparatos e eletrodos foram otimizados e seus desempenhos foram avaliados primeiramente empregando-se potenciostatos/ galvanostatos comerciais. Para isso, determinações em modo individual ou simultâneo dos íons Zn2+, Cd2+ e Pb2+ foram realizadas empregando-se a técnica de parada de fluxo e detecção por voltametria de redissolução anódica por onda quadrada (SWASV) empregando SPE-BiF e por pulso diferencial (DPASV) empregando SPE-BDD. Limites de detecção (LDs) de 1,60 μg L-1, 0,30 μg L-1 e 0,09 μg L-1 foram obtidos para a determinação simultânea dos íons de Zn2+, Cd2+ e Pb2+, respectivamente, empregando-se SPE-BiF ex situ com SWASV. No caso de SPEBDD- DPASV, foram obtidos LDs de 2,50 μg L-1, 0,38 μg L-1 e 0,10 μg mL-1, respectivamente para a determinação supramencionada. Determinações dos analitos, separados ou simultaneamente, também foram realizadas com SPE-BDD empregando amperometria de múltiplos pulsos (MPA); os LDs obtidos foram 150 μg L-1, 87,0 μg L-1 e 13,0 μg L-1 respectivamente, com uma frequência de amostragem de 54 determinações por hora. Em paralelo às determinações eletroanalíticas supracitadas, desenvolveu-se o PG004 na seguinte sequência: i) desenvolvimento do circuito eletrônico; ii) calibrações PG004; iii) montagem do PG004 com o módulo em fluxo acoplado; iv) acoplamento dos periféricos de transmissão de dados sem fio (wireless) para comunicação Bluetooth®, Wi-Fi® e 3G, e receptor GPS à CPU do PG004; v) montagem da unidade de alimentação a base de baterias de 12 V e X placas de captação de energia solar. Em seguida, o PG004 foi empregado na determinação dos íons Cd2+ e Pb2+ com SPE-BDD e SWASV em laboratório com simulação das condições em campo. Posteriormente, o PG004 foi conduzido a campo para as determinações in situ dos íons Cd2+ e Pb2+. Resultados satisfatórios foram obtidos, tais como: i) determinações individuais e simultâneas dos íons Cd2+ e Pb2+ com percentual de recuperação entre 93,3 a 109 %; ii) voltamogramas não ruidosos com boa resolução; iii) recepção das coordenadas geográficas com o GPS e envio de dados experimentais via tecnologia de telefonia móvel (GPRS); iv) autonomia maior de energia com uso das placas de captação de energia solar; v) sistema automatizado de captação, filtração e controle termostático da temperatura para análises in situ; vi) SPE-BiF ou SPE-BDD reaproveitados e/ou reutilizados ao fim das análises e vii) baixa geração de resíduo por determinação (700 μL).
2

Desenvolvimento de dispositivos eletroquímicos baseados em papel para monitoramento não invasivo de lactato em suor / Development of wearable electrochemical paper-based devices for noninvasive monitoring of lactate in sweat

Gomes, Nathalia Oezau 22 February 2019 (has links)
O lactato é um metabólito chave formado pelo metabolismo anaeróbico da glicose nos músculos, e tem se tornado um biomarcador importante no âmbito clínico e esportivo. Atualmente, existem biossensores eletroquímicos portáteis que são capazes de determinar os níveis de lactato no organismo em tempo real. No entanto, tal método é invasivo uma vez que requer amostras de sangue. O presente projeto tem como objetivo desenvolver um biossensor eletroquímico descartável para detecção de lactato no suor. Para isto a configuração do dispositivo foi feita utilizando a celulose bacteriana como substrato para obtenção de um dispositivo que seja resistente à deformação mecânica, especialmente quando molhado e, também, permeável ao suor. A impressão dos eletrodos de carbono neste substrato foi efetuada utilizando o processo de serigrafia. Com os dispositivos produzidos foram realizados experimentos de voltametria cíclica e espectroscopia de impedância eletroquímica, a fim de caracterizar o sensor desenvolvido e investigar a influência do pré-tratamento eletroquímico na sua performance analítica. A partir da modificação da superfície eletródica com nanocubos de Azul da Prússia foi possível desenvolver um sensor eletroquímico para detecção de peróxido de hidrogênio. A cronoamperometria foi utilizada para a determinação da curva analítica para o peróxido de hidrogênio. Com todos os parâmetros da cronoamperometria otimizados, uma dependência linear da corrente catódica com a concentração de peróxido de hidrogênio foi obtida, com a equação: Ip = 0,1 + 4,30 [H2O2], com r2 = 0,999 (n = 3). Esta curva analítica mostrou que a metodologia apresenta um Limite de Detecção e de Quantificação de mol L-1 e mol L-1, respectivamente. Para a configuração do biossensor eletroquímico a enzima lactato oxidase foi incorporada à superfície do papel pelo método de ligação covalente. Adotando esta metodologia foi verificado um aumento da área eletroativa que possibilitou uma melhora significativa no desempenho do sensor desenvolvido. No qual se obteve uma região linear de 1-24,0 mmol L-1 em suor sintético, obtendo-se Limites de detecção e Quantificação de e mol L-1. Tais parâmetros se mostraram adequados já que o suor pode apresentar níveis de aproximadamente 25 mmol L-1 de lactato. De modo geral, foi possível desenvolver uma plataforma eletroquímica no substrato de celulose bacteriana para a detecção de lactato em amostras de suor sintético. O dispositivo desenvolvido apresentou uma boa durabilidade e resistência ao se executarem sucessivas medidas corroborando a viabilidade deste substrato na projeção de sensores vestíveis para a aplicação direta na pele e monitoramento dos níveis de lactato em tempo real. / Lactate is a key metabolite formed in the anaerobic metabolism of glucose in the muscles. It has become an important biomarker in the clinical and sport scopes. Currently, there are portable biosensors that are able to determine lactate levels in real time. However, these methods are invasive since they require blood samples. Herein, we aim to develop a disposable wearable electrochemical biosensor for detection of lactate in sweat. For this purpose the configuration of the device was made with bacterial cellulose substrate in order to be permeable to sweat and resistant to mechanical deformation, especially when wet. The fabrication of the electrodes was made through screen printing technique. Electrochemical impedance spectroscopy and cyclic voltammetry were used to characterize the sensor developed in order to investigate the influence of the electrochemical pre-treatment in the analytical performance of the electrodes. To develop an electrochemical sensor for the detection of hydrogen peroxide the screen printed electrode was modified with Prussian blue nanocubes. Chronoamperometry experiments were used to detect of hydrogen peroxide. From optimized chronoamperometry parameters, a linear dependence of the cathodic current with the hydrogen peroxide concentration was obtained with the equation: Ip = 0.1 + 4.30 [H2O2], with r2 = 0.999 (n = 3). The limit of detection (LOD) and the limit of quantification (LOQ) were mol L-1 e mol L-1, respectively. For the configuration of the electrochemical biosensor the lactate oxidase enzyme was immobilized on the paper surface by the covalent bonding method. Adopting this methodology was verified an increase of the electroactive area that allowed a significant improvement in the performance of the developed sensor. In which a linear concentration range of 1-24.0 mmol L-1 was obtained in the synthetic sweat, obtaining LOD and LOQ of mol L-1 e mol L-1, respectively. Such parameters were adequate since sweat may have lactate levels of approximately 25 mmol L-1. Finally, it was possible to develop an electrochemical platform using the bacterial cellulose substrate for the detection of lactate in samples of synthetic sweat. The developed device presented a good durability and resistance when performing electrochemical measurements assuring the feasibility of this substrate in the projection of wearable sensors for the direct application to skin and monitoring of lactate levels in real time.
3

Detecção e quantificação eletroquímica de substâncias de interesse clínico, ambiental e forense utilizando eletrodo de pasta de grafite modificado com trisilanol poss ligado a suportes porosos e eletrodos impressos obtidos via screen-printed / Electrochemical detection and quantification of clinical, environmental and forensic interest substances using carbon paste electrode modified with trisilanol-poss bonded to porous supports and screen-printed electrodes

Cumba, Loanda Raquel [UNESP] 04 March 2016 (has links)
Submitted by LOANDA RAQUEL CUMBA null (loandacumba@gmail.com) on 2016-04-18T17:28:50Z No. of bitstreams: 1 Tese Final - Loanda Cumba (2016).pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-04-19T16:39:26Z (GMT) No. of bitstreams: 1 cumba_lr_dr_ilha.pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) / Made available in DSpace on 2016-04-19T16:39:26Z (GMT). No. of bitstreams: 1 cumba_lr_dr_ilha.pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) Previous issue date: 2016-03-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho descreve a preparação, caracterização e aplicação eletroanalítica de um metalosilsesquioxano ligado em uma sílica mesoporosa (MCM-41) e em uma zeólita (H-FAU-Si/Al 40) com hexacianoferrato de níquel adsorvido em sua superfície. Algumas técnicas espectroscópicas como: Espectroscopia no infravermelho por transformada de Fourier (FTIR), Microscopia eletrônica de varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS) e Voltametria cíclica, foram utilizadas na caracterização dos materiais formados. Os espectros na região do Infravermelho para o MTTiPNiH e ZTTiPNiH apresentaram as bandas de seus precursores (TTiP, MCM-41 e H-FAU-Si/Al 40), apenas duas absorções diferiram dos demais espectros, uma em, aproximadamente, 2168 cm-1 e outra a 2098 cm-1, tais resultados foram atribuídos ao estiramento ν (C≡N). Para o MTTIPNiH, através das micrografias pode-se observar partículas com tamanhos variados, entre 0,30 µm a 0,60 µm. Para o ZTTiPNiH as micrografias apresentaram um pequeno aumento no tamanho de partículas, aproximadamente de 50 nm, quando comparado a seus precursores. O EDS determinou a composição química semi-quantitativa dos elementos carbono, oxigênio, silício, titânio, fósforo, níquel e ferro, presentes em ambas as amostras. O eletrodo de pasta de grafite exibiu um par redox bem definido com potencial de médio padrão (E°’) de +0,53 V e +0,51 V para o MTTiPNiH e ZTTiPNiH, respectivamente, atribuído ao processo redox FeII(CN)6 / FeIII(CN)6 em presença de níquel. O eletrodo de pasta de grafite modificado com MTTiPNiH apresentou atividade eletrocatalítica para dipirona e para o sulfito, já o eletrodo de pasta de grafite modificado com ZTTiPNiH apresentou atividade eletrocatalítica apenas para o sulfito. Em uma segunda etapa, prepararam-se eletrodos impressos via screen-printed para detecção e quantificação de pindolol utilizando a técnica de voltametria de onda quadrada em uma faixa de concentração de 0,10 µmol L-1 – 10,0 µmol L-1. Após a detecção de pindolol, o protocolo de detecção foi utilizado na avaliação e recuperação desta substância a partir de urina humana. Eletrodos impressos via screen-printed foram empregados pela primeira vez na detecção da substância psicoativa Synthacaine. A detecção eletroquímica indireta para MPA/2-AI simultaneamente, utilizando eletrodos impressos apresentou resultados satisfatórios. Após a detecção simultânea de MPA e 2-AI, amostras reais de Synthacaine foram utilizadas para quantificar, através de técnicas eletroquímicas, estes analitos por meio do protocolo de detecção anteriormente proposto. / This research describes the preparation, characterization and electroanalytical application of a metalosilsesquioxane bonded in mesoporous silica (MCM-41) and in zeolite (H-FAU-Si/Al 40) with nickel hexacyanoferrate adsorbed on their surface. Techniques as fourier transform infra-red spectroscopy (FTIR), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and cyclic voltammetry were used in the characterization of the synthesized materials. The spectra in the infrared region for MTTiPNiH and ZTTiPNiH showed the bands of their precursors (TTiP, MCM-41 and H-FAU Si/Al 40), only two absorption differed from the others spectra, one at, approximately, 2168 cm-1 and another at 2098 cm-1 , which were attributed to stretching ν(C≡N). For MTTIPNiH through the micrographs can be observed particles with varied sizes between 0.30 µM to 0.60 µm. For ZTTiPNiH the micrographs showed a small increase in particle size, approximately, 50 nm, as compared to their precursors. EDS determined the semi-quantitative chemical composition of carbon, oxygen, silicon, titanium, phosphorus, nickel and iron present in both samples. The carbon paste electrode exhibited a well-defined redox couple with E°' = +0.53 V and +0.51 V for MTTiPNiH and ZTTiPNiH, respectively, attributed to the redox process FeII(CN)6 / FeIII(CN)6 in presence of nickel. Carbon paste electrode modified with MTTiPNiH showed electrocatalytic activity to dipyrone and sulfite. However the carbon paste electrode modified with ZTTiPNiH showed electrocatalytic activity only for sulfite. In a second step, screenprinted electrodes were produced for the detection and quantification of pindolol using square wave voltammetry technique at a concentration range of 0.10 µmol L-1 to 10.0 µmol L-1 . After pindolol detection, the protocol of detection was used in the evaluation and recovery of pindolol from human urine. Screen-printed electrodes were used for the first time in the detection of psychoactive substance Synthacaine. Indirect electrochemical detection for MPA/2-AI simultaneously, using Screen-printed electrodes showed satisfactory results. After the simultaneous detection of MPA and 2-AI, real samples of Synthacaine were used to quantify through electrochemical techniques, these analytes by protocol of detection previously proposed.
4

Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares / Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals

Fialho, Ana Cristina Vasconcelos 21 October 2011 (has links)
Made available in DSpace on 2016-06-02T19:02:40Z (GMT). No. of bitstreams: 1 3890.pdf: 2739392 bytes, checksum: fdb93cb69cafb89992f3e6a155deacfb (MD5) Previous issue date: 2011-10-21 / The Biosafety is a very important tool for the Control of Hospital Infection establishing through methods, techniques and standards, measures to be adopted in order to prevent and control risks that may contribute to hospital infection. This work reports the development of an impedimetric immunosensor for detection of pathogenic bacteria, specifically Staphylococcus aureus (S. aureus), in hospital critical areas (Surgical Centers and Intensive Care Units) to contribute to the hospital infection control. Different parameters were studied: direct immobilization of protein A of S. aureus on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for protein A and anti- S. aureus antibodies; blocking with bovine serum albumin (BSA) and immunoassay (antigen-antibody reaction, Ag-Ab). Electrochemical techniques (electrochemical impedance spectroscopy - EIS and cyclic voltammetry - CV) and non electrochemical (microscopy) were used for the characterization and construction of the immunosensor. The impedance measurements and cyclic voltammetry showed the good results with self-assembled monolayer of cystamine 2 x 10-2 mol L-1 and glutaraldehyde 2,5% with incubation periods of 2 and 1h, respectively; immobilization of protein A 1:20 (tincub = 12 h) and anti-S. aureus monoclonal Ab (tincub = 3 h) and step blocking with 0.5% BSA (tincub = 1 h). For the Ag-Ab interaction S. aureus ATCC - 6535 strains (analyte) were used and incubation for 30 min. The immunosensor developed has proven to be an effective method for monitoring of S. aureus in a hospital environment and that can be applied as an indicative tool of the effectiveness of the standards and procedures applied to the control of hospital infection. / A Biossegurança constitui uma ferramenta de grande relevância para o Controle da Infecção Hospitalar estabelecendo através de métodos, técnicas e normas, condutas a serem adotadas com o intuito de prevenir e controlar os riscos que podem favorecer à infecção hospitalar. Este trabalho relata o desenvolvimento de um imunossensor impedimétrico para detecção de Staphylococcus aureus (S. aureus), em áreas críticas hospitalares (Centros Cirúrgicos e Unidades de Terapia Intensiva) visando contribuir para o controle de infecção hospitalar. Diferentes parâmetros foram estudados: imobilização direta da proteína A de S. aureus na superfície do transdutor ou eletrodo de trabalho (screen-printed electrode - SPE); imobilização da proteína A sobre SPEs modificados com monocamadas auto-organizadas (SAMs) de cistamina (CYS) e glutaraldeído (GA); diferentes tempos de incubação e diluições foram utilizados tanto para os modificadores como para a proteína A e anticorpos anti-S. aureus; bloqueio com soroalbumina bovina (SAB) e imunoensaio (reação antígeno-anticorpo, Ag-Ac). Técnicas eletroquímicas (espectroscopia de impedância eletroquímica - EIS e voltametria cíclica - VC) e não eletroquímicas (microscopias) foram utilizadas para a caracterização e construção do imunossensor. As medidas de impedância e voltametria cíclica mostraram bons resultados com monocamadas auto-organizadas de cistamina 2 x 10-2 mol L-1 e glutaraldeído 2,5% com tempos de incubação de 2 e 1 h, respectivamente;assim como as imobilizações da proteína A 1:20 (tincub = 12 h); Ac monoclonais anti-S. aureus (tincub = 3 h) e etapa de bloqueio com SAB 0,5% (tincub = 1 h). Na interação Ag-Ac utilizou-se cepas de S. aureus ATCC - 6535 (analito) e incubação de 30 min. O imunossensor desenvolvido indicou ser um método efetivo para monitoramento de S. aureus em ambiente hospitalar e que pode ser aplicado como instrumento indicativo da efetividade das normas e condutas aplicadas para o controle de infecção hospitalar.
5

Detecção e quantificação eletroquímica de substâncias de interesse clínico, ambiental e forense utilizando eletrodo de pasta de grafite modificado com trisilanol poss ligado a suportes porosos e eletrodos impressos obtidos via screen-printed /

Cumba, Loanda Raquel January 2016 (has links)
Orientador: Devaney Ribeiro do Carmo / Resumo: O presente trabalho descreve a preparação, caracterização e aplicação eletroanalítica de um metalosilsesquioxano ligado em uma sílica mesoporosa (MCM-41) e em uma zeólita (H-FAU-Si/Al 40) com hexacianoferrato de níquel adsorvido em sua superfície. Algumas técnicas espectroscópicas como: Espectroscopia no infravermelho por transformada de Fourier (FTIR), Microscopia eletrônica de varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS) e Voltametria cíclica, foram utilizadas na caracterização dos materiais formados. Os espectros na região do Infravermelho para o MTTiPNiH e ZTTiPNiH apresentaram as bandas de seus precursores (TTiP, MCM-41 e H-FAU-Si/Al 40), apenas duas absorções diferiram dos demais espectros, uma em, aproximadamente, 2168 cm-1 e outra a 2098 cm-1, tais resultados foram atribuídos ao estiramento ν (C≡N). Para o MTTIPNiH, através das micrografias pode-se observar partículas com tamanhos variados, entre 0,30 µm a 0,60 µm. Para o ZTTiPNiH as micrografias apresentaram um pequeno aumento no tamanho de partículas, aproximadamente de 50 nm, quando comparado a seus precursores. O EDS determinou a composição química semi-quantitativa dos elementos carbono, oxigênio, silício, titânio, fósforo, níquel e ferro, presentes em ambas as amostras. O eletrodo de pasta de grafite exibiu um par redox bem definido com potencial de médio padrão (E°’) de +0,53 V e +0,51 V para o MTTiPNiH e ZTTiPNiH, respectivamente, atribuído ao processo redox FeII(CN)6 / FeIII(CN)6 em... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This research describes the preparation, characterization and electroanalytical application of a metalosilsesquioxane bonded in mesoporous silica (MCM-41) and in zeolite (H-FAU-Si/Al 40) with nickel hexacyanoferrate adsorbed on their surface. Techniques as fourier transform infra-red spectroscopy (FTIR), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and cyclic voltammetry were used in the characterization of the synthesized materials. The spectra in the infrared region for MTTiPNiH and ZTTiPNiH showed the bands of their precursors (TTiP, MCM-41 and H-FAU Si/Al 40), only two absorption differed from the others spectra, one at, approximately, 2168 cm-1 and another at 2098 cm-1 , which were attributed to stretching ν(C≡N). For MTTIPNiH through the micrographs can be observed particles with varied sizes between 0.30 µM to 0.60 µm. For ZTTiPNiH the micrographs showed a small increase in particle size, approximately, 50 nm, as compared to their precursors. EDS determined the semi-quantitative chemical composition of carbon, oxygen, silicon, titanium, phosphorus, nickel and iron present in both samples. The carbon paste electrode exhibited a well-defined redox couple with E°' = +0.53 V and +0.51 V for MTTiPNiH and ZTTiPNiH, respectively, attributed to the redox process FeII(CN)6 / FeIII(CN)6 in presence of nickel. Carbon paste electrode modified with MTTiPNiH showed electrocatalytic activity to dipyrone and sulfite. However the carbon paste electrode... (Complete abstract click electronic access below) / Doutor
6

Desenvolvimento de sensor impresso nanoestruturado modificado com ftalocianina de cobalto para aplicação em Imunossensores

LEITE, Diego Ricardo da Silva 04 February 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-09-20T12:39:54Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Diego_Ricardo_daSilva_Leite_DISSERTAÇÃO.pdf: 2264802 bytes, checksum: 0e31f6102f6a8c9b24148d435e822ef1 (MD5) / Made available in DSpace on 2016-09-20T12:39:54Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Diego_Ricardo_daSilva_Leite_DISSERTAÇÃO.pdf: 2264802 bytes, checksum: 0e31f6102f6a8c9b24148d435e822ef1 (MD5) Previous issue date: 2016-02-04 / CAPES / Atualmente, têm-se buscado métodos que viabilizem um diagnóstico eficaz, prático, rápido e de baixo custo na detecção de doenças que se revelem atrativos para os serviços de saúde pública. Nesse contexto, os imunossensores têm apresentado respostas promissoras, revelando-se como métodos analíticos práticos, rápidos e econômicos. Recentemente, a utilização de nanomateriais de alótropos de carbono, destacando-se os nanotubos de carbono (NTC), têm resultado em melhoria na sensibilidade por aumentar transferência eletrônica, sobretudo quando aliados a polímeros condutores. O objetivo deste trabalho foi desenvolver plataforma nanoestruturada para aplicação em imunossensores. Como objeto de estudo, foi detectado anticorpos contra o nucleocapsídeo do vírus da hepatite B (HBV), visto que este marcador é o mais importante no controle e vigilância de bolsas de sangue em serviços hemoterápicos. No presente trabalho, eletrodos de tinta de carbono serigrafados sobre substrato de politileno tereftalato (PET) foram modificados por 0,0063% de nanotubos de carbono (NTC-COOH) e 6% em concentração de ftalocianina de cobalto (CoPc) que foram recobertos com filmes de polipirrol (PPi). O filme foi obtido por cronoamperometria (0,8V, 80s) usando soluções de 0,1 M de pirrol (Pi) em meio ácido. Foi observada uma boa reprodutibilidade e estabilidade dos eletrodos sobretudo pós-inserção do filme quando caracterizado eletroquimicamente. Além disso, as imagens de microscopia eletrônica mostraram uma baixa produção de pirroles. Os sensores desenvolvidos com a associação de nanotubos de carbono funcionalizados apresentaram melhor desempenho analítico em relação ao controle (sem NTC). A imobilização do antígeno do núcleo capsídeo da hepatite B (HBc-Ag) foi confirmada por decréscimo da área eletroativa dos voltamogramas cíclicos. A resposta aos anticorpos anti-HBc foi evidenciada por técnica de voltametria de onda quadrada, mostrando que a plataforma desenvolvida é promissora para aplicação em sensor para hepatite. / Currently, they have been sought methods that enable effective diagnosis, practical, fast and low-cost in detecting diseases that may prove attractive to public health services. In this context, immunosensors have shown promising responses, revealing himself as analytical methods of practical, fast and economical. Recently, the use of carbon allotropes of nanomaterials, highlighting carbon nanotubes (CNT), have resulted in improved sensitivity by increasing wire transfer, especially when combined with conductive polymers. The aim of this study was to develop nanostructured platform for immunosensors application. As study object was detected antibodies against the nucleocapsid of hepatitis B virus (HBV), as this marker is the most important in the control and surveillance of blood bags in haemotherapic services. In this study, carbon ink electrodes screen printed on the substrate polythene terephthalate (PET) have been modified for 0.0063% of carbon nanotubes (CNT-COOH) and 6% concentration of cobalt phthalocyanine (CoPc) were coated with polypyrrole films (PPy). The film was obtained by chronoamperometry (0.8 V, 80 s) using 0.1 M solution of pyrrole (Py) in acidic. Was observed a good reproducibility and stability particularly after insertion of the film electrode when electrochemically characterized. Furthermore, electron microscopy images showed a low production pyrroles. The sensors developed in association with functionalized carbon nanotubes showed better analytical performance compared to the control (without NTC). The immobilization of the capsid antigen hepatitis B core (HBc-Ag) was confirmed by decreasing the area of the electroactive cyclic voltammograms. The response to anti-HBc antibody was evidenced by technical square wave voltammetry, showing that the platform is developed promising for application to sensor hepatitis.
7

Desenvolvimento de novos sensores eletroquímicos descartáveis para fins analíticos / Development of new disposable electrochemical sensors for analytical purposes

Souza, Ana Paula Ruas de 16 October 2015 (has links)
O presente trabalho trata do desenvolvimento de sensores eletroquímicos que possuam características descartáveis e ao uso destes dispositivos para a determinação de diferentes analitos em amostras biológicas, farmacêuticas e de interesse ambiental. O desenvolvimento e a aplicação dos sensores foram divididos em seis capítulos. O primeiro capítulo corresponde a fabricação de conjuntos de microeletrodos em suporte de CD-RW e placa fenolite utilizando impressão com tinta toner. Os conjuntos de microeletrodos foram fabricados por meio da deposição de duas máscaras de toner em um substrato de cobre ou ouro. Os eletrodos fabricados neste capítulo foram caracterizados e aplicados nos capítulos subsequentes. Os resultados da aplicação do conjunto de microeletrodos de cobre (DCRM) foram descritos no segundo capítulo. Os dispositivos foram aplicados para a determinação de peróxido de hidrogênio em amostras de antisséptico bucal e clareadores dentais. As determinações foram realizadas em solução de tampão fosfato (pH 7.0) por meio da técnica de amperometria (E = -0,2 V). Estes sensores foram também aplicados para determinação de ácido acetilsalítico (AAS) em amostras farmacêuticas em solução de hidróxido de sódio 0,1 mol L-1 por amperometria (E = 0,6 V). A determinação de nitrato em amostra de água de rio foi realizada por amperometria (E = -0,45V) em solução de sulfato de sódio 0,1 mol L-1 (pH = 2,0). Os resultados obtidos com o sensor demonstraram o sucesso das aplicações. As principais vantagens deste dispositivo dizem respeito à simplicidade de fabricação, baixo custo do equipamento e rapidez das análises. A caracterização eletroquímica do sensor e a determinação de ciclopirox olamina em solução de tampão BR 0,1 mol L-1 (pH = 5,0) utilizando o conjunto de microeletrodos de ouro (CD-RW) foi apresentada no terceiro capítulo. Os resultados obtidos mostraram que é possível realizar a determinação desta espécie de interesse em soluções oftalmológicas. O desenvolvimento, a caracterização e aplicação de um novo conjunto de microeletrodos de ouro fabricados a partir da redução eletroquímica da 5-bromo-1,10-fenantrolina em solução de dimetilformalmida (DMF) foi investidada no quarto capítulo. A superfície foi bloqueada com um filme isolante de 1,10-fenantrolina e o sensor foi caracterizado como um conjunto de microeletrodos de ouro. O sensor foi aplicado para a determinação de peróxido de hidrogênio, nas condições descritas anteriormente a fim de avaliar a aplicabilidade deste dispositivo. Os resultados obtidos foram promissores. A utilização de um eletrodo de microbanda impresso na configuração \"back-to-back\" foi descrita no quinto capítulo. A configuração faz uso da impressão de um novo eletrodo nas costas de um eletrodo impresso \"tradicional\", aumentando com isso a sensibilidade do sensor. O eletrodo impresso na configuração \"back-to-back\" foi utilizado para a determinação de íons Pb(II) em amostras de água potável por meio da técnica de voltametria de redissolução anódica por onda quadrada e os resultados obtidos foram concordantes com os encontrados utilizando espectrometria de emissão atômica por plasma acoplado. Os eletrodos de microbanda impressos na configuração \"back-to-back\" modificados com nanotubos de carbono para a determinação de capsaicina e dopamina e com ftalocianina de cobalto (II) para determinação de hidrazina foram investigados no sexto capítulo. Os resultados obtidos foram concordantes com aqueles descritos em outros trabalhos encontrados na literatura. / This work presents results on the fabrication of disposable electrochemical sensors and the use of such devices for the determination of different analytes in biological, pharmaceutical and environmental samples. The development and application of these sensors have been divided into six chapters. The first chapter describes the fabrication of a microelectrode ensemble (CD-RW) using ink toner. The sensor was fabricated by deposition of two toner pattern masks on copper and gold substrates. The electrodes fabricated according this procedure were characterized and applied in subsequent chapters. The second chapter describes the use of a disposable copper random microarrays (DCRM) for the amperometric determination of three analytes: hydrogen peroxide in real samples (oral antiseptic and dental whitening) at -0.2 V in phosphate buffer (pH 7.0) solution, acetylsalicylic acid (ASA) in pharmaceutical formulations at 0.6 V in 0.10 mol L-1 NaOH solution and nitrate in river samples at -0.45V in a 0.10 mol L-1 sodium sulfate solution (pH 2.0). The good results obtained with the DCRM demonstrated the successful application of this new sensor. The main advantages of the proposed manufacturing procedure are the simplicity, low cost of equipment and the high speed of production. The third chapter presents results on the use of a gold random microarray (GRM) for the determination of ciclopirox olamine in 0.10 mol L-1 Britton Robinson buffer solution (pH 5.0). Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V. The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products and the results obtained agreed well with those found by potentiometric titration and the labeled values. The fourth chapter describes the fabrication of a random assembly of microelectrodes (RAMs) by electrochemical reduction of 5-bromo-1,10- phenathroline in N,N-dimethylformamide (DMF), generating the 1,10-phenanthroline radical, which was covalently grafted on gold electrodes. After several potential cycles, the gold surface was partially blocked with an insulating film of 1,10-phenanthroline and the resulting modified electrode exhibited the characteristics of RAMs for the electrochemical reduction of the reversible probe 1,4-benzoquinone in DMF. This sensor was applied for hydrogen peroxide detection at -0.2 V in phosphate buffer (pH 7.0) solution. The fifth chapter reports on the use of screen-printed back-to-back microband electroanalytical sensors for quantification of lead(II) ions in drinking water samples in 0.01 mol L-1 HCl and the validation of the results by ICP-OES. The sixth chapter shows results on the use of back-to-back screen-printed microband electrodes modified with single-walled carbon nanotubes and cobalt phthalocyanine. The electroanalytical applications of this novel electrode configuration were exemplified towards the sensing of dopamine, capsaicin and hydrazine.
8

Desenvolvimento de novos sensores eletroquímicos descartáveis para fins analíticos / Development of new disposable electrochemical sensors for analytical purposes

Ana Paula Ruas de Souza 16 October 2015 (has links)
O presente trabalho trata do desenvolvimento de sensores eletroquímicos que possuam características descartáveis e ao uso destes dispositivos para a determinação de diferentes analitos em amostras biológicas, farmacêuticas e de interesse ambiental. O desenvolvimento e a aplicação dos sensores foram divididos em seis capítulos. O primeiro capítulo corresponde a fabricação de conjuntos de microeletrodos em suporte de CD-RW e placa fenolite utilizando impressão com tinta toner. Os conjuntos de microeletrodos foram fabricados por meio da deposição de duas máscaras de toner em um substrato de cobre ou ouro. Os eletrodos fabricados neste capítulo foram caracterizados e aplicados nos capítulos subsequentes. Os resultados da aplicação do conjunto de microeletrodos de cobre (DCRM) foram descritos no segundo capítulo. Os dispositivos foram aplicados para a determinação de peróxido de hidrogênio em amostras de antisséptico bucal e clareadores dentais. As determinações foram realizadas em solução de tampão fosfato (pH 7.0) por meio da técnica de amperometria (E = -0,2 V). Estes sensores foram também aplicados para determinação de ácido acetilsalítico (AAS) em amostras farmacêuticas em solução de hidróxido de sódio 0,1 mol L-1 por amperometria (E = 0,6 V). A determinação de nitrato em amostra de água de rio foi realizada por amperometria (E = -0,45V) em solução de sulfato de sódio 0,1 mol L-1 (pH = 2,0). Os resultados obtidos com o sensor demonstraram o sucesso das aplicações. As principais vantagens deste dispositivo dizem respeito à simplicidade de fabricação, baixo custo do equipamento e rapidez das análises. A caracterização eletroquímica do sensor e a determinação de ciclopirox olamina em solução de tampão BR 0,1 mol L-1 (pH = 5,0) utilizando o conjunto de microeletrodos de ouro (CD-RW) foi apresentada no terceiro capítulo. Os resultados obtidos mostraram que é possível realizar a determinação desta espécie de interesse em soluções oftalmológicas. O desenvolvimento, a caracterização e aplicação de um novo conjunto de microeletrodos de ouro fabricados a partir da redução eletroquímica da 5-bromo-1,10-fenantrolina em solução de dimetilformalmida (DMF) foi investidada no quarto capítulo. A superfície foi bloqueada com um filme isolante de 1,10-fenantrolina e o sensor foi caracterizado como um conjunto de microeletrodos de ouro. O sensor foi aplicado para a determinação de peróxido de hidrogênio, nas condições descritas anteriormente a fim de avaliar a aplicabilidade deste dispositivo. Os resultados obtidos foram promissores. A utilização de um eletrodo de microbanda impresso na configuração \"back-to-back\" foi descrita no quinto capítulo. A configuração faz uso da impressão de um novo eletrodo nas costas de um eletrodo impresso \"tradicional\", aumentando com isso a sensibilidade do sensor. O eletrodo impresso na configuração \"back-to-back\" foi utilizado para a determinação de íons Pb(II) em amostras de água potável por meio da técnica de voltametria de redissolução anódica por onda quadrada e os resultados obtidos foram concordantes com os encontrados utilizando espectrometria de emissão atômica por plasma acoplado. Os eletrodos de microbanda impressos na configuração \"back-to-back\" modificados com nanotubos de carbono para a determinação de capsaicina e dopamina e com ftalocianina de cobalto (II) para determinação de hidrazina foram investigados no sexto capítulo. Os resultados obtidos foram concordantes com aqueles descritos em outros trabalhos encontrados na literatura. / This work presents results on the fabrication of disposable electrochemical sensors and the use of such devices for the determination of different analytes in biological, pharmaceutical and environmental samples. The development and application of these sensors have been divided into six chapters. The first chapter describes the fabrication of a microelectrode ensemble (CD-RW) using ink toner. The sensor was fabricated by deposition of two toner pattern masks on copper and gold substrates. The electrodes fabricated according this procedure were characterized and applied in subsequent chapters. The second chapter describes the use of a disposable copper random microarrays (DCRM) for the amperometric determination of three analytes: hydrogen peroxide in real samples (oral antiseptic and dental whitening) at -0.2 V in phosphate buffer (pH 7.0) solution, acetylsalicylic acid (ASA) in pharmaceutical formulations at 0.6 V in 0.10 mol L-1 NaOH solution and nitrate in river samples at -0.45V in a 0.10 mol L-1 sodium sulfate solution (pH 2.0). The good results obtained with the DCRM demonstrated the successful application of this new sensor. The main advantages of the proposed manufacturing procedure are the simplicity, low cost of equipment and the high speed of production. The third chapter presents results on the use of a gold random microarray (GRM) for the determination of ciclopirox olamine in 0.10 mol L-1 Britton Robinson buffer solution (pH 5.0). Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V. The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products and the results obtained agreed well with those found by potentiometric titration and the labeled values. The fourth chapter describes the fabrication of a random assembly of microelectrodes (RAMs) by electrochemical reduction of 5-bromo-1,10- phenathroline in N,N-dimethylformamide (DMF), generating the 1,10-phenanthroline radical, which was covalently grafted on gold electrodes. After several potential cycles, the gold surface was partially blocked with an insulating film of 1,10-phenanthroline and the resulting modified electrode exhibited the characteristics of RAMs for the electrochemical reduction of the reversible probe 1,4-benzoquinone in DMF. This sensor was applied for hydrogen peroxide detection at -0.2 V in phosphate buffer (pH 7.0) solution. The fifth chapter reports on the use of screen-printed back-to-back microband electroanalytical sensors for quantification of lead(II) ions in drinking water samples in 0.01 mol L-1 HCl and the validation of the results by ICP-OES. The sixth chapter shows results on the use of back-to-back screen-printed microband electrodes modified with single-walled carbon nanotubes and cobalt phthalocyanine. The electroanalytical applications of this novel electrode configuration were exemplified towards the sensing of dopamine, capsaicin and hydrazine.
9

Desenvolvimento de metodologias eletroanalíticas para a determinação de metais em biocombustíveis empregando a análise por injeção em batelada (BIA) / Development of electroanalytical procedures for determination of metals in biofuels employing batch injection analysis (BIA)

Tormin, Thiago Faria 20 December 2016 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Nesta tese foi demonstrado que a associação da técnica eletroanalítica Voltametria de Redissolução Anódica de Onda Quadrada (SWASV, do inglês, Square-Wave Anodic Stripping Voltammetry) com a Análise por Injeção em Batelada (BIA, do inglês, Batch- Injection Analysis) permite o desenvolvimento de métodos analíticos para a determinação de metais (Cu, Cd, Pb, Hg e Zn) em amostras de etanol combustível e biodiesel. Metais podem ser incorporados aos biocombustíveis em processos de armazenagem e transporte, podendo causar danos irreversíveis ao biocombustível, o qual pode danificar motores e causar problemas ambientais. Logo, justifica-se o presente trabalho pela necessidade do desenvolvimento de métodos analíticos visando o controle de qualidade em relação ao teor de metais nestas amostras, preferencialmente métodos de fácil manuseio, rápidos, de baixo custo e robustos. BIA-SWASV permitiu a determinação direta (sem qualquer diluição da amostra) de Cd, Pb, Cu e Zn em etanol combustível empregando eletrodos de Au e filme de Hg. Limites de detecção na faixa de 0,6 a 5 pg L-1, faixa linear de 12,5 a 200 pg L-1 e valores de recuperação entre 87 e 109% foram obtidos para análises de 1 mL de amostra e tempo de deposição de 90 s (tempo total de cada medida de ~200 s). O tempo de injeção da amostra pela micropipeta eletrônica usada no sistema BIA foi de 40 s, ou seja, a deposição dos metais ocorreu mesmo após o término da injeção (transporte difusional das espécies ao eletrodo). Além disso, esta tese apresenta a associação de eletrodos impressos (SPE, do inglês, Screen-Printed Electrode) ao sistema BIA visando o desenvolvimento de métodos analíticos com características portáteis. Este sistema foi combinado a outros componentes que funcionam com uso de baterias como, pipetas eletrônicas, mini-potenciostatos e computador laptop, e aplicado à determinação de metais (Pb, Cu e Hg) em amostras de biodiesel após digestão ácida. Empregaram-se nos experimentos SPE’s com tinta condutora de Au (SPGE, do inglês, Screen-Printed Gold Electrode) como eletrodo de trabalho, reduzindo o volume de amostra a 200 pL (em eletrodos convencionais utilizou-se 1000 pL) com tempo de injeção de 40 s (velocidade de injeção de 5 gL s-1) e, nestas condições, obtiveram-se limites de detecção abaixo de 1,0 gg L-1 (equivalente a 6 gg g-1), faixa linear entre 20 e 280 gg L-1 e valores de recuperação entre 90 e 110% para amostras de biodiesel fortificadas. O baixo consumo de amostra no sistema BIA prolongou o tempo de vida útil do SPGE para um dia inteiro de análises (210 injeções). O sistema BIA associado a técnicas eletroanalíticas permitiu o desenvolvimento de métodos analíticos de baixo custo, simples, precisos, que empregam pequeno volume de amostra, portáteis (sobretudo com o emprego de SPE’s), que podem ser aplicados para a determinação de rotina e em campo de metais em amostras de etanol combustível e biodiesel. / In this thesis it is shown that the association of electroanalytical technique Square- Wave Anodic Stripping Voltammetry (SWASV) with Batch-Injection Analysis (BIA) allows the development of analytical methods for determination of metals (Cu, Cd, Pb, Hg and Zn) in ethanol fuel and biodiesel samples. Metals can be incorporated into biofuels during storage and transportation processes, which can damage engines and cause environmental problems. Therefore, it becomes necessary to develop analytical methods aiming the quality control of metals in these samples, preferably methods that are easy to operate, fast, inexpensive and robust. BIA-SWASV allowed direct determination (no dilution of the sample) of Cd, Pb, Cu and Zn in fuel ethanol employing Au and Hg film electrodes. Detection limits in the range of 0.6 to 5 pg L"1, linear range from 12.5 to 200 pg L-1 and recovery values of between 87 and 109% were obtained for analysis of 1 mL of sample and deposition time of 90 s (total time of each measurement of ~200 s). The time of sample injection by the electronic micropipette used by the BIA system was 40 s, that is, the deposition of metal occurred even after the end of injection (diffusional transport of species to the electrode). In addition, in this thesis it is presented the combination of Screen-Printed Electrodes (SPE) to the BIA system aimed to the development of analytical methods with portable characteristics. This system was combined with other components that operate using batteries as electronic pipettes, mini- potentiostat and laptop computer, and applied to the determination of metals (Pb, Cu and Hg) in biodiesel samples after acid digestion. It was used in the experiments SPE's with Au conductive ink as a working electrode (SPGE), reduced the volume of sample to 200 pL (in conventional electrodes was used 1000 pL) with injection time of 40 s (injection rate of 5 pL s-1), and in these conditions, detection limits lower than 1,0 pg L-1 (equivalent to 6 pg g-1), linear range between 20 and 280 pg L-1 and recovery values between 90 and 110% for biodiesel fortified samples were obtained. The low sample consumption extended the lifetime SPGE’s for a whole day of analysis (210 injections). BIA system associated with electroanalytical techniques allowed the development of inexpensive,simple, accurate, portable (especially with the use of SPE's) analytical methods, employing reduced sample volume, which can be applied for the routine and on-site determinations of metals in ethanol fuel and biodiesel samples. / Tese (Doutorado)

Page generated in 0.0543 seconds