Spelling suggestions: "subject:"modificação eletroquímica"" "subject:"codificação eletroquímica""
1 |
Modificação eletroquímica da superfície de filmes finos de ouro SERS e SPR ativosJarske, André Oliveira Silva January 2011 (has links)
Thin metal films have attracted much interest because they provide a way to produce surface plasmon resonance (SPR) in the Kretschmann configuration. This technique is a very sensitive for determining small changes at the interface between a metallic layer and
a dielectric medium, and the metals generally used are silver and gold once their surface plasmon resonances are located in the visible range. Thin films of gold, due their stability and diversity applications, have been extensively studied by electrochemistry, surface enhanced Raman spectroscopy (SERS) and techniques of Microscopic such as AFM and
STM. The Raman technique has been used to the analysis of organics compounds in determined system. However, in very low concentration levels is inefficient due to weak signal or interference from noise. A developed method to markedly increase the signal of a species presented at many levels is the SERS. One of the major considerations for the formation of a SERS-active surface is surface roughness, and this has been realized by various ways. In the present work, we analyzed the efects of various oxidation-reduction cycles (ORCs) on the surface of the thin films of gold using the techniques of cyclic voltammetry, microscopy, UV-Vis spectroscopy and SPR, which will be used to evaluate
the efficiency of electrochemically modified substrates as SERS and SPR active. Initially,
the film was cycling in a solution of H2SO4 to remove impurities from the surface. After
this procedure, the 50 nm and 100 nm thick gold films, deposited on a glass substrate,
were subjected to a series of ORCs in a solution of H2SO4 containing 0,005 M KCl
electrolyte. As the number of ORCs is increased, the roughness of the film increased. We used techniques of microscopy, Spectroscopy UV-Vis, Resonance Plasmon Surface and Cyclic Voltammetry to characterize the surface of the film as a function of roughness. A “home − made” SPR system based on the configuration of Kretschmann was utilized for analyzed the changes provoked in surface film before and after the electrochemically
modified. The medium size of the gold islands deposited was analyzed for Atomic Force
Microscopy (AFM) and Scanning Tunneling Microscopy (STM). This same metallic film,
after passing for oxidation processes and reduction, was used to obtain a spectrum SER
using an organic molecule the 2-thiouracil adsorbed on the surface of the film. The results observed for AFM, STM and cyclic voltammetry shows that surfaces electrochemically modified increase the roughness, and that the changes modified o depth of the signal SPR. These change provoked electrochemistry after various ORC improve significantly the Raman sign of molecules adsorbed on the surfaces of the metallic films. Finally, we conducted an evaluation of the roughness factor obtained through the techniques of AFM, STM and cyclic voltammetry. _______________________________________________________________________________________ RESUMO: Filmes finos metalicos tem despertado muito interesse devido a possibildade de produzir Ressonancia de Plasmons de Superfıcie (SPR) utilizando uma configuracao de Kretschmann. Esta tecnica e muito sensıvel na determinacao de pequenas mudancas na interface entre uma camada metalica e um meio dieletrico, e os metais usados geralmente
sao prata e ouro, uma vez que a ressonancia de plasmon da superfıcie desses metais
esta localizada na regiao do visıvel. Esses filmes, devido a sua estabilidade e diversidade de aplicacoes, tem sido extensivamente estudados por tecnicas eletroquımicas, espectroscopia Raman intenficada por superfıcie (SERS) e por tecnicas de microscopia tais como o AFM e STM. A Espectroscopia Raman tem sido utilizada para a analise de compostos
organicos em determinados sistemas. No entanto, em sistemas que possuem concentracoes muito baixas, o sinal Raman e extremamente fraco e ineficiente, ou sofre interferencias de ruıdos. Um dos metodos desenvolvidos para aumentar significativamente o sinal de uma especie adsorvida sobre uma superfıcie metalica em varios nıveis e o SERS. Uma das consideracoes importantes para a formacao de um substrato SERS ativo e a rugosidade da superfıcie, e a obtencao dessas superfıcies tem sido realizado de diversas maneiras. No presente trabalho, analisamos o efeito de diferentes ciclos de oxidacao-reducao (ORCs) sobre a superfıcie de filmes finos de ouro, utilizando as tecnicas de voltametria cıclica, microscopias, espectroscopia UV-Vis e SPR, que serao utilizadas para avaliar a eficiencia dos substratos modificados eletroquimicamente como SERS e SPR ativos. Inicialmente, o filme e ciclado em uma solucao de H2SO4 para remover as impurezas da superfıcie. Apos este procedimento, os filmes com espessuras de 50 e 100 nm, depositados sobre um substrato de vidro, foram submetidos a uma serie de ORCs em uma solucao de H2SO4.
|
2 |
Redução de oxigênio molecular em soluções aquosas através da metodologia de modificação de eletrodos / Reduction of molecular oxygen in aqueous solutions through modifying electrodes\' methodologyZacarias, Nara Alexiou 27 September 2007 (has links)
Este trabalho consistiu de estudos da viabilidade da geração e identificação de radicais livres envolvidos em processos oxidativos avançados por via eletroquímica. Para a geração e identificação de radicais livres em eletrodos modificados com organotióis via eletroquímica, escolheu-se uma técnica pouco aplicada para este fim; a espectroscopia de impedância eletroquímica, e o ajuste dos dados experimentais pela proposta de modelos de circuitos equivalentes. O eletrodo de trabalho utilizado (Au) foi caracterizado em meio ácido e básico e diversas monocamadas auto-organizadas conhecidas foram adsorvidas sobre o mesmo e também caracterizadas por esta técnica. Parâmetros importantes como constante dielétrica, capacitância de uma monocamada livre de defeitos e grau de recobrimento foram determinados com êxito. Também foram empregadas moléculas menos utilizadas como modificadoras de eletrodos (fenotiazinas e derivados). As mesmas foram caracterizadas no sistema Au/adsorvente/NaOH, pois, o pH alto garante a formação do radical superóxido e do ânion hidroperóxido. Os mesmos modelos de circuitos equivalentes puderam ser empregados na obtenção dos parâmetros físicos relativos a essas moléculas no sistema eletroquímico utilizado. Em uma etapa subsequente obteve-se a valiosa informação, se as moléculas adsorvidas sobre Au poderiam ser usadas para a geração de superóxido e outros radicais. As monocamadas de tióis, quando utilizadas para gerar radicais livres, se mostraram aptas a gerar superóxido em meio alcalino saturado com oxigênio molecular. Como se demonstrou na etapa de caracterização, as SAM-3 e SAM-6 não formaram um empacotamento totalmente hidrofóbico. Por este motivo, mesmo que superóxido tenha sido gerado, não pôde ser detectado. Já para a fenotiazina e seu metil-derivado, a cinética de adsorção e a utilização de soluções aquosas impediram a formação de um filme completo e homogêneo, imprescindível para a constituição de uma interface hidrofóbica e isolante. Além disso, possíveis reações de complexação entre as moléculas e superóxido, reações entre a fenotiazina cátion-radical e superóxido fazem necessários mais estudos acerca da natureza eletroquímica do sistema, que já é bastante conhecido fotoquimicamente. Posterior a modificação, todos os eletrodos se mostraram ser bastante sensíveis ao pH e aos eletrólitos utlizados, alterando-se a estrutura interna muito facilmente, o qual implica uma limitação no tempo de uso e reprodutibilidade quando da geração de um radical tão reativo quanto superóxido. / This work consisted in testing the viability of investigations into the electrochemical generation and identification of free radicals involved in advanced oxidative processes. In these studies, a technique which is rarely used for the electrochemical generation and identification of free radicals at organothiole-modified electrodes, electrochemical impedancy spectroscopy, was chosen and the experimental data obtained were fitted by equivalent circuit models. A working electrode (Au) was characterized in both acidic and basic media and several known self-assembled monolayers were adsorbed over this electrode and also characterized using this technique. Important parameters such as dielectric constants, capacitance of the monolayers free of defects and coverage were determined with success. Other lesser-known molecules such as phenothiazines and their derivatives were also used .The modified electrodes were characterized in NaOH solution, since the high pH assures the production of superoxide radicals and hydroperoxylate anions. The equivalent circuit model was employed to obtain physical parameters for these molecules in the electrochemical systems studied. In a subsequent step, a valuable piece of information was obtained; it was noted that the molecules adsorbed over Au could be used in order to generate superoxide and other radicals. The ability of thiol monolayers used in the generation of free radicals, to produce superoxides in alkaline media saturated with molecular oxygen was demonstrated. However, characterization of the self-assembled monolayers, SAM-3 and SAM-6, revealed that these were not able to pack in a completely hydrophobic manner. This may account for the fact that the superoxide could not be detected even when it was believed to have formed. For the phenothiazine-modified electrodes, the adsorption kinetics and the utilization of aqueous solutions prevented the formation of an intact and homogeneous film, which is essential in establishing a hydrophobic and isolating interface. Furthermore, possible complexation reactions between the molecules and the superoxide and reactions between the phenothiazine cation-radical and superoxide, point to the need for further studies regarding the electrochemical nature of this system, whose photochemical properties are very well known. Following modification, all the electrodes were shown to be too sensitive to pH and to the electrolytes used, since the inner structure was easily modified, which implies that they would have a limited time of use and in addition that the reproducibility of the rate of generation of reactive radical species such as superoxides could be compromised.
|
3 |
Redução de oxigênio molecular em soluções aquosas através da metodologia de modificação de eletrodos / Reduction of molecular oxygen in aqueous solutions through modifying electrodes\' methodologyNara Alexiou Zacarias 27 September 2007 (has links)
Este trabalho consistiu de estudos da viabilidade da geração e identificação de radicais livres envolvidos em processos oxidativos avançados por via eletroquímica. Para a geração e identificação de radicais livres em eletrodos modificados com organotióis via eletroquímica, escolheu-se uma técnica pouco aplicada para este fim; a espectroscopia de impedância eletroquímica, e o ajuste dos dados experimentais pela proposta de modelos de circuitos equivalentes. O eletrodo de trabalho utilizado (Au) foi caracterizado em meio ácido e básico e diversas monocamadas auto-organizadas conhecidas foram adsorvidas sobre o mesmo e também caracterizadas por esta técnica. Parâmetros importantes como constante dielétrica, capacitância de uma monocamada livre de defeitos e grau de recobrimento foram determinados com êxito. Também foram empregadas moléculas menos utilizadas como modificadoras de eletrodos (fenotiazinas e derivados). As mesmas foram caracterizadas no sistema Au/adsorvente/NaOH, pois, o pH alto garante a formação do radical superóxido e do ânion hidroperóxido. Os mesmos modelos de circuitos equivalentes puderam ser empregados na obtenção dos parâmetros físicos relativos a essas moléculas no sistema eletroquímico utilizado. Em uma etapa subsequente obteve-se a valiosa informação, se as moléculas adsorvidas sobre Au poderiam ser usadas para a geração de superóxido e outros radicais. As monocamadas de tióis, quando utilizadas para gerar radicais livres, se mostraram aptas a gerar superóxido em meio alcalino saturado com oxigênio molecular. Como se demonstrou na etapa de caracterização, as SAM-3 e SAM-6 não formaram um empacotamento totalmente hidrofóbico. Por este motivo, mesmo que superóxido tenha sido gerado, não pôde ser detectado. Já para a fenotiazina e seu metil-derivado, a cinética de adsorção e a utilização de soluções aquosas impediram a formação de um filme completo e homogêneo, imprescindível para a constituição de uma interface hidrofóbica e isolante. Além disso, possíveis reações de complexação entre as moléculas e superóxido, reações entre a fenotiazina cátion-radical e superóxido fazem necessários mais estudos acerca da natureza eletroquímica do sistema, que já é bastante conhecido fotoquimicamente. Posterior a modificação, todos os eletrodos se mostraram ser bastante sensíveis ao pH e aos eletrólitos utlizados, alterando-se a estrutura interna muito facilmente, o qual implica uma limitação no tempo de uso e reprodutibilidade quando da geração de um radical tão reativo quanto superóxido. / This work consisted in testing the viability of investigations into the electrochemical generation and identification of free radicals involved in advanced oxidative processes. In these studies, a technique which is rarely used for the electrochemical generation and identification of free radicals at organothiole-modified electrodes, electrochemical impedancy spectroscopy, was chosen and the experimental data obtained were fitted by equivalent circuit models. A working electrode (Au) was characterized in both acidic and basic media and several known self-assembled monolayers were adsorbed over this electrode and also characterized using this technique. Important parameters such as dielectric constants, capacitance of the monolayers free of defects and coverage were determined with success. Other lesser-known molecules such as phenothiazines and their derivatives were also used .The modified electrodes were characterized in NaOH solution, since the high pH assures the production of superoxide radicals and hydroperoxylate anions. The equivalent circuit model was employed to obtain physical parameters for these molecules in the electrochemical systems studied. In a subsequent step, a valuable piece of information was obtained; it was noted that the molecules adsorbed over Au could be used in order to generate superoxide and other radicals. The ability of thiol monolayers used in the generation of free radicals, to produce superoxides in alkaline media saturated with molecular oxygen was demonstrated. However, characterization of the self-assembled monolayers, SAM-3 and SAM-6, revealed that these were not able to pack in a completely hydrophobic manner. This may account for the fact that the superoxide could not be detected even when it was believed to have formed. For the phenothiazine-modified electrodes, the adsorption kinetics and the utilization of aqueous solutions prevented the formation of an intact and homogeneous film, which is essential in establishing a hydrophobic and isolating interface. Furthermore, possible complexation reactions between the molecules and the superoxide and reactions between the phenothiazine cation-radical and superoxide, point to the need for further studies regarding the electrochemical nature of this system, whose photochemical properties are very well known. Following modification, all the electrodes were shown to be too sensitive to pH and to the electrolytes used, since the inner structure was easily modified, which implies that they would have a limited time of use and in addition that the reproducibility of the rate of generation of reactive radical species such as superoxides could be compromised.
|
4 |
Desenvolvimento de novos sensores eletroquímicos descartáveis para fins analíticos / Development of new disposable electrochemical sensors for analytical purposesSouza, Ana Paula Ruas de 16 October 2015 (has links)
O presente trabalho trata do desenvolvimento de sensores eletroquímicos que possuam características descartáveis e ao uso destes dispositivos para a determinação de diferentes analitos em amostras biológicas, farmacêuticas e de interesse ambiental. O desenvolvimento e a aplicação dos sensores foram divididos em seis capítulos. O primeiro capítulo corresponde a fabricação de conjuntos de microeletrodos em suporte de CD-RW e placa fenolite utilizando impressão com tinta toner. Os conjuntos de microeletrodos foram fabricados por meio da deposição de duas máscaras de toner em um substrato de cobre ou ouro. Os eletrodos fabricados neste capítulo foram caracterizados e aplicados nos capítulos subsequentes. Os resultados da aplicação do conjunto de microeletrodos de cobre (DCRM) foram descritos no segundo capítulo. Os dispositivos foram aplicados para a determinação de peróxido de hidrogênio em amostras de antisséptico bucal e clareadores dentais. As determinações foram realizadas em solução de tampão fosfato (pH 7.0) por meio da técnica de amperometria (E = -0,2 V). Estes sensores foram também aplicados para determinação de ácido acetilsalítico (AAS) em amostras farmacêuticas em solução de hidróxido de sódio 0,1 mol L-1 por amperometria (E = 0,6 V). A determinação de nitrato em amostra de água de rio foi realizada por amperometria (E = -0,45V) em solução de sulfato de sódio 0,1 mol L-1 (pH = 2,0). Os resultados obtidos com o sensor demonstraram o sucesso das aplicações. As principais vantagens deste dispositivo dizem respeito à simplicidade de fabricação, baixo custo do equipamento e rapidez das análises. A caracterização eletroquímica do sensor e a determinação de ciclopirox olamina em solução de tampão BR 0,1 mol L-1 (pH = 5,0) utilizando o conjunto de microeletrodos de ouro (CD-RW) foi apresentada no terceiro capítulo. Os resultados obtidos mostraram que é possível realizar a determinação desta espécie de interesse em soluções oftalmológicas. O desenvolvimento, a caracterização e aplicação de um novo conjunto de microeletrodos de ouro fabricados a partir da redução eletroquímica da 5-bromo-1,10-fenantrolina em solução de dimetilformalmida (DMF) foi investidada no quarto capítulo. A superfície foi bloqueada com um filme isolante de 1,10-fenantrolina e o sensor foi caracterizado como um conjunto de microeletrodos de ouro. O sensor foi aplicado para a determinação de peróxido de hidrogênio, nas condições descritas anteriormente a fim de avaliar a aplicabilidade deste dispositivo. Os resultados obtidos foram promissores. A utilização de um eletrodo de microbanda impresso na configuração \"back-to-back\" foi descrita no quinto capítulo. A configuração faz uso da impressão de um novo eletrodo nas costas de um eletrodo impresso \"tradicional\", aumentando com isso a sensibilidade do sensor. O eletrodo impresso na configuração \"back-to-back\" foi utilizado para a determinação de íons Pb(II) em amostras de água potável por meio da técnica de voltametria de redissolução anódica por onda quadrada e os resultados obtidos foram concordantes com os encontrados utilizando espectrometria de emissão atômica por plasma acoplado. Os eletrodos de microbanda impressos na configuração \"back-to-back\" modificados com nanotubos de carbono para a determinação de capsaicina e dopamina e com ftalocianina de cobalto (II) para determinação de hidrazina foram investigados no sexto capítulo. Os resultados obtidos foram concordantes com aqueles descritos em outros trabalhos encontrados na literatura. / This work presents results on the fabrication of disposable electrochemical sensors and the use of such devices for the determination of different analytes in biological, pharmaceutical and environmental samples. The development and application of these sensors have been divided into six chapters. The first chapter describes the fabrication of a microelectrode ensemble (CD-RW) using ink toner. The sensor was fabricated by deposition of two toner pattern masks on copper and gold substrates. The electrodes fabricated according this procedure were characterized and applied in subsequent chapters. The second chapter describes the use of a disposable copper random microarrays (DCRM) for the amperometric determination of three analytes: hydrogen peroxide in real samples (oral antiseptic and dental whitening) at -0.2 V in phosphate buffer (pH 7.0) solution, acetylsalicylic acid (ASA) in pharmaceutical formulations at 0.6 V in 0.10 mol L-1 NaOH solution and nitrate in river samples at -0.45V in a 0.10 mol L-1 sodium sulfate solution (pH 2.0). The good results obtained with the DCRM demonstrated the successful application of this new sensor. The main advantages of the proposed manufacturing procedure are the simplicity, low cost of equipment and the high speed of production. The third chapter presents results on the use of a gold random microarray (GRM) for the determination of ciclopirox olamine in 0.10 mol L-1 Britton Robinson buffer solution (pH 5.0). Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V. The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products and the results obtained agreed well with those found by potentiometric titration and the labeled values. The fourth chapter describes the fabrication of a random assembly of microelectrodes (RAMs) by electrochemical reduction of 5-bromo-1,10- phenathroline in N,N-dimethylformamide (DMF), generating the 1,10-phenanthroline radical, which was covalently grafted on gold electrodes. After several potential cycles, the gold surface was partially blocked with an insulating film of 1,10-phenanthroline and the resulting modified electrode exhibited the characteristics of RAMs for the electrochemical reduction of the reversible probe 1,4-benzoquinone in DMF. This sensor was applied for hydrogen peroxide detection at -0.2 V in phosphate buffer (pH 7.0) solution. The fifth chapter reports on the use of screen-printed back-to-back microband electroanalytical sensors for quantification of lead(II) ions in drinking water samples in 0.01 mol L-1 HCl and the validation of the results by ICP-OES. The sixth chapter shows results on the use of back-to-back screen-printed microband electrodes modified with single-walled carbon nanotubes and cobalt phthalocyanine. The electroanalytical applications of this novel electrode configuration were exemplified towards the sensing of dopamine, capsaicin and hydrazine.
|
5 |
Desenvolvimento de novos sensores eletroquímicos descartáveis para fins analíticos / Development of new disposable electrochemical sensors for analytical purposesAna Paula Ruas de Souza 16 October 2015 (has links)
O presente trabalho trata do desenvolvimento de sensores eletroquímicos que possuam características descartáveis e ao uso destes dispositivos para a determinação de diferentes analitos em amostras biológicas, farmacêuticas e de interesse ambiental. O desenvolvimento e a aplicação dos sensores foram divididos em seis capítulos. O primeiro capítulo corresponde a fabricação de conjuntos de microeletrodos em suporte de CD-RW e placa fenolite utilizando impressão com tinta toner. Os conjuntos de microeletrodos foram fabricados por meio da deposição de duas máscaras de toner em um substrato de cobre ou ouro. Os eletrodos fabricados neste capítulo foram caracterizados e aplicados nos capítulos subsequentes. Os resultados da aplicação do conjunto de microeletrodos de cobre (DCRM) foram descritos no segundo capítulo. Os dispositivos foram aplicados para a determinação de peróxido de hidrogênio em amostras de antisséptico bucal e clareadores dentais. As determinações foram realizadas em solução de tampão fosfato (pH 7.0) por meio da técnica de amperometria (E = -0,2 V). Estes sensores foram também aplicados para determinação de ácido acetilsalítico (AAS) em amostras farmacêuticas em solução de hidróxido de sódio 0,1 mol L-1 por amperometria (E = 0,6 V). A determinação de nitrato em amostra de água de rio foi realizada por amperometria (E = -0,45V) em solução de sulfato de sódio 0,1 mol L-1 (pH = 2,0). Os resultados obtidos com o sensor demonstraram o sucesso das aplicações. As principais vantagens deste dispositivo dizem respeito à simplicidade de fabricação, baixo custo do equipamento e rapidez das análises. A caracterização eletroquímica do sensor e a determinação de ciclopirox olamina em solução de tampão BR 0,1 mol L-1 (pH = 5,0) utilizando o conjunto de microeletrodos de ouro (CD-RW) foi apresentada no terceiro capítulo. Os resultados obtidos mostraram que é possível realizar a determinação desta espécie de interesse em soluções oftalmológicas. O desenvolvimento, a caracterização e aplicação de um novo conjunto de microeletrodos de ouro fabricados a partir da redução eletroquímica da 5-bromo-1,10-fenantrolina em solução de dimetilformalmida (DMF) foi investidada no quarto capítulo. A superfície foi bloqueada com um filme isolante de 1,10-fenantrolina e o sensor foi caracterizado como um conjunto de microeletrodos de ouro. O sensor foi aplicado para a determinação de peróxido de hidrogênio, nas condições descritas anteriormente a fim de avaliar a aplicabilidade deste dispositivo. Os resultados obtidos foram promissores. A utilização de um eletrodo de microbanda impresso na configuração \"back-to-back\" foi descrita no quinto capítulo. A configuração faz uso da impressão de um novo eletrodo nas costas de um eletrodo impresso \"tradicional\", aumentando com isso a sensibilidade do sensor. O eletrodo impresso na configuração \"back-to-back\" foi utilizado para a determinação de íons Pb(II) em amostras de água potável por meio da técnica de voltametria de redissolução anódica por onda quadrada e os resultados obtidos foram concordantes com os encontrados utilizando espectrometria de emissão atômica por plasma acoplado. Os eletrodos de microbanda impressos na configuração \"back-to-back\" modificados com nanotubos de carbono para a determinação de capsaicina e dopamina e com ftalocianina de cobalto (II) para determinação de hidrazina foram investigados no sexto capítulo. Os resultados obtidos foram concordantes com aqueles descritos em outros trabalhos encontrados na literatura. / This work presents results on the fabrication of disposable electrochemical sensors and the use of such devices for the determination of different analytes in biological, pharmaceutical and environmental samples. The development and application of these sensors have been divided into six chapters. The first chapter describes the fabrication of a microelectrode ensemble (CD-RW) using ink toner. The sensor was fabricated by deposition of two toner pattern masks on copper and gold substrates. The electrodes fabricated according this procedure were characterized and applied in subsequent chapters. The second chapter describes the use of a disposable copper random microarrays (DCRM) for the amperometric determination of three analytes: hydrogen peroxide in real samples (oral antiseptic and dental whitening) at -0.2 V in phosphate buffer (pH 7.0) solution, acetylsalicylic acid (ASA) in pharmaceutical formulations at 0.6 V in 0.10 mol L-1 NaOH solution and nitrate in river samples at -0.45V in a 0.10 mol L-1 sodium sulfate solution (pH 2.0). The good results obtained with the DCRM demonstrated the successful application of this new sensor. The main advantages of the proposed manufacturing procedure are the simplicity, low cost of equipment and the high speed of production. The third chapter presents results on the use of a gold random microarray (GRM) for the determination of ciclopirox olamine in 0.10 mol L-1 Britton Robinson buffer solution (pH 5.0). Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V. The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products and the results obtained agreed well with those found by potentiometric titration and the labeled values. The fourth chapter describes the fabrication of a random assembly of microelectrodes (RAMs) by electrochemical reduction of 5-bromo-1,10- phenathroline in N,N-dimethylformamide (DMF), generating the 1,10-phenanthroline radical, which was covalently grafted on gold electrodes. After several potential cycles, the gold surface was partially blocked with an insulating film of 1,10-phenanthroline and the resulting modified electrode exhibited the characteristics of RAMs for the electrochemical reduction of the reversible probe 1,4-benzoquinone in DMF. This sensor was applied for hydrogen peroxide detection at -0.2 V in phosphate buffer (pH 7.0) solution. The fifth chapter reports on the use of screen-printed back-to-back microband electroanalytical sensors for quantification of lead(II) ions in drinking water samples in 0.01 mol L-1 HCl and the validation of the results by ICP-OES. The sixth chapter shows results on the use of back-to-back screen-printed microband electrodes modified with single-walled carbon nanotubes and cobalt phthalocyanine. The electroanalytical applications of this novel electrode configuration were exemplified towards the sensing of dopamine, capsaicin and hydrazine.
|
Page generated in 0.0877 seconds