• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • Tagged with
  • 19
  • 19
  • 19
  • 19
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A utiliza??o da pesquisa operacional para o gerenciamento dos leitos em um hospital particular: estudo de caso baseado em simula??o computacional

Freitas, H?rica D?bora Praxedes de 20 December 2013 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-02-22T22:00:14Z No. of bitstreams: 1 HericaDeboraPraxedesDeFreitas_DISSERT.pdf: 1504087 bytes, checksum: a718ad824d00dc4fe80cd4a7106319a9 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-02-24T20:33:31Z (GMT) No. of bitstreams: 1 HericaDeboraPraxedesDeFreitas_DISSERT.pdf: 1504087 bytes, checksum: a718ad824d00dc4fe80cd4a7106319a9 (MD5) / Made available in DSpace on 2016-02-24T20:33:31Z (GMT). No. of bitstreams: 1 HericaDeboraPraxedesDeFreitas_DISSERT.pdf: 1504087 bytes, checksum: a718ad824d00dc4fe80cd4a7106319a9 (MD5) Previous issue date: 2013-12-20 / O hospital ? um local de a??es complexas onde s?o realizadas diversas atividades de atendimento ? popula??o tais como: consultas, exames, cirurgias, pronto?atendimento, interna??es em enfermarias e unidades de terapias intensivas. Estas atividades se misturam ? ansiedade, ? impaci?ncia, ao desespero e ? ang?stia dos pacientes e de seus familiares, quest?es que envolvem equil?brio emocional tanto por parte dos profissionais que prestam servi?os, quanto das pessoas por elas atendidas. A crise da sa?de no Brasil agrava-se a cada ano e hoje se constitui num grande problema para os hospitais particulares. Os enfermos que acorrem ?s emerg?ncias aumentam progressivamente, e em contrapartida, n?o h? oferta de leitos hospitalares na mesma propor??o, gerando superlota??o, queda na qualidade da assist?ncia prestada aos pacientes, desgaste dos profissionais da ?rea de sa?de e dificuldade na gest?o dos leitos. Este trabalho apresenta uma pesquisa que busca construir uma ferramenta alternativa que possa contribuir com o gerenciamento de leitos de um hospital particular. Busca tamb?m, identificar poss?veis gargalos ou defici?ncias e, consequentemente, efetuar altera??es nesse fluxo para obter um aumento na capacidade de atendimento, reduzindo assim os custos, sem comprometer a qualidade dos servi?os prestados. A ferramenta utilizada foi a simula??o computacional baseada em eventos discretos, com a qual se pretende identificar os principais par?metros a serem considerados para uma adequada modelagem desse sistema. O presente estudo tomou como refer?ncia a interna??o de um hospital particular, com base no cen?rio atual, onde seus apartamentos encontram-se em n?vel de satura??o quanto a sua taxa de ocupa??o. O projeto de realoca??o dos leitos tem como objetivo atender ? crescente demanda por cirurgias e interna??es constatada pela atual administra??o. / The hospital is a place of complex actions, where several activities for serving the population are performed such as: medical appointments, exams, surgeries, emergency care, admission in wards and ICUs. These activities are mixed with anxiety, impatience, despair and distress of patients and their families, issues involving emotional balance both for professionals who provide services for them as for people cared by them. The healthcare crisis in Brazil is getting worse every year and today, constitutes a major problem for private hospitals. The patient that comes to emergencies progressively increase, and in contrast, there is no supply of hospital beds in the same proportion, causing overcrowding, declines in the quality of care delivered to patients, drain of professionals of the health area and difficulty in management the beds. This work presents a study that seeks to create an alternative tool that can contribute to the management of a private hospital beds. It also seeks to identify potential issues or deficiencies and therefore make changes in flow for an increase in service capacity, thus reducing costs without compromising the quality of services provided. The tool used was the Computational Simulation ?based in discrete event, which aims to identify the main parameters to be considered for a proper modeling of this system. This study took as reference the admission of a private hospital, based on the current scenario, where your apartments are in saturation level as its occupancy rate. The relocation of project beds aims to meet the growing demand for surgeries and hospital admissions observed by the current administration.
2

Propaga??o de danos em sistemas cooperativos: propriedades termodin?micas

Anjos Filho, Ant?nio Soares dos 14 November 2008 (has links)
Made available in DSpace on 2014-12-17T15:14:46Z (GMT). No. of bitstreams: 1 AntonioSAF.pdf: 1214999 bytes, checksum: c500092609bb7d7681af9a0f37dcaf88 (MD5) Previous issue date: 2008-11-14 / High-precision calculations of the correlation functions and order parameters were performed in order to investigate the critical properties of several two-dimensional ferro- magnetic systems: (i) the q-state Potts model; (ii) the Ashkin-Teller isotropic model; (iii) the spin-1 Ising model. We deduced exact relations connecting specific damages (the difference between two microscopic configurations of a model) and the above mentioned thermodynamic quanti- ties which permit its numerical calculation, by computer simulation and using any ergodic dynamics. The results obtained (critical temperature and exponents) reproduced all the known values, with an agreement up to several significant figures; of particular relevance were the estimates along the Baxter critical line (Ashkin-Teller model) where the exponents have a continuous variation. We also showed that this approach is less sensitive to the finite-size effects than the standard Monte-Carlo method. This analysis shows that the present approach produces equal or more accurate results, as compared to the usual Monte Carlo simulation, and can be useful to investigate these models in circumstances for which their behavior is not yet fully understood / Atrav?s de c?lculos de alta precis?o das fun??es de correla??o e dos par?metros de ordem, investigamos as propriedades cr?ticas de v?rios modelos ferromagn?ticos bidimensionais, a saber: (i) Potts q-estados; (ii) Ashkin-Teller isotr?pico; (iii) Ising de spin-1. Utilizamos simula??es computacionais, obtidas a partir de rela??es anal?ticas exatas, conectando as quantidades acima mencionadas e certas combina??es de Danos (diferen?as entre duas configura??es microsc?picas de um modelo), que s?o v?lidas para qualquer din?mica erg?dica. Todos os resultados encontrados (temperaturas e expoentes cr?ticos) concordam com os valores conhecidos, em v?rias casas decimais, destacando-se em particular a reprodu??o da linha de Baxter (no caso ii) onde os expoentes variam continuamente, resultado de dif?cil obten??o por m?todos tradicionais. Tamb?m mostramos que este m?todo ? menos sens?vel aos efeitos de tamanho finito que aqueles baseados no procedimento usual de simula??o de Monte-Carlo. Tais fatos indicam a potencialidade desta abordagem para investigar situa??es ainda insuficientemente exploradas, nos modelos acima analisados e em outros semelhantes
3

Simula??o computacional para avalia??o da qualidade ac?stica do audit?rio da escola de m?sica da UFRN

Alves, Jair da Silva 01 December 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-01-15T21:40:47Z No. of bitstreams: 1 JairDaSilvaAlves_DISSERT.pdf: 33462595 bytes, checksum: 8bd795ddf58f46634b22553c3d2e9f66 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-01-17T13:43:07Z (GMT) No. of bitstreams: 1 JairDaSilvaAlves_DISSERT.pdf: 33462595 bytes, checksum: 8bd795ddf58f46634b22553c3d2e9f66 (MD5) / Made available in DSpace on 2018-01-17T13:43:07Z (GMT). No. of bitstreams: 1 JairDaSilvaAlves_DISSERT.pdf: 33462595 bytes, checksum: 8bd795ddf58f46634b22553c3d2e9f66 (MD5) Previous issue date: 2017-12-01 / Em um ambiente utilizado principalmente para apresenta??es musicais, o grau de inteligibilidade das informa??es musicais e de outros aspectos ac?sticos ? o que possibilita a an?lise da qualidade dos sons que s?o recebidos pelos ouvintes e, consequentemente, permite uma avalia??o das caracter?sticas ac?sticas da sala. Essa an?lise ? realizada por meio da avalia??o de par?metros objetivos, os quais podem ser obtidos atrav?s de t?cnicas de medi??o e de simula??o computacional. Com o avan?o da tecnologia e o desenvolvimento de pesquisas referentes ? ac?stica arquitet?nica ao longo dos anos, v?rios softwares de avalia??o da qualidade ac?stica de salas foram desenvolvidos, tornando-os ferramentas essenciais para a previs?o do comportamento do som em diversos tipos de ambientes. Este estudo tem por objetivo avaliar, por meio de medi??o e simula??o computacional, par?metros que s?o capazes de representar o comportamento ac?stico do Audit?rio Onofre Lopes (AOL) da Escola de M?sica da Universidade Federal do Rio Grande do Norte (EMUFRN), no intuito de propor diretrizes gerais de projeto para otimiza??o das caracter?sticas ac?sticas desse ambiente. Os par?metros ac?sticos foram obtidos, primeiramente, a partir da medi??o da resposta impulsiva da sala. Atrav?s da constru??o de um modelo digital tridimensional do audit?rio, as caracter?sticas ac?sticas dos materiais que revestem as superf?cies internas da sala, bem como as caracter?sticas eletroac?sticas das fontes sonoras presentes no ambiente foram modeladas com o aux?lio de um software de simula??o computacional. Ap?s a valida??o do modelo, realizada atrav?s da compara??o dos resultados de Tempo de Reverbera??o (RT) obtidos nas medi??es e nas simula??es, os par?metros ac?sticos Early Decay Time (EDT), Clareza (C80), Defini??o (D50), Tempo Central (Ts) e Speech Transmission Index (STI) foram simulados e avaliados de acordo os valores recomendados na literatura. Como resultado da pesquisa, os valores coletados nas medi??es e simula??es apontaram que o AOL ? um espa?o que possui caracter?sticas ac?sticas inadequadas ? fala e pouco eficientes quando utilizado para m?sica. Dessa forma, algumas diretrizes de condicionamento ac?stico foram simuladas, com o objetivo de aperfei?oar a resposta temporal ac?stica para a utiliza??o do audit?rio como um espa?o destinado a m?ltiplos usos. / In a room used mainly for musical presentations, the intelligibility levels of musical information and other acoustic aspects allow the analysis of the quality of the sounds received by the listeners and, consequently, allows an evaluation of room's acoustic characteristics. This analysis is performed by the evaluation of objective parameters, which can be obtained by measurement and computational simulation techniques. With the advancement of technology and the development of research related to architectural acoustics over the years, several software for evaluating acoustic room quality were developed, making them essential tools for predicting the behavior of sound in different types of halls. The aim of this study is to evaluate, through computer measurement and simulation, parameters that are able to represent the acoustic behavior of the Onofre Lopes Auditorium (AOL) of the School of Music of the Federal University of Rio Grande do Norte (EMUFRN), in order to propose general guidelines to optimize its acoustic characteristics. These room's acoustic parameters were obtained by measuring it impulse response. Through the construction of a threedimensional digital model of the auditorium, the acoustic characteristics of the materials that covers its internal surfaces, as well electroacoustic characteristics of the sound sources present in this space were modeled with the aid of computer simulation software. After the validation of the model, by comparing Reverberation Time (RT) results obtained in the measurements and simulations, the acoustic parameters Early Decay Time (EDT), Clarity (C80), Definition (D50), Center Time (Ts) and Speech Transmission Index (STI) were simulated and evaluated according to the values recommended in the literature. As a result of this research, the values collected in the measurements and simulations pointed out that the AOL is a space that has inadequate acoustic characteristics to speech and may be considered inefficient when used for music. Thus, some acoustic conditioning guidelines were simulated to improve the acoustic temporal response to the use of the auditorium as a multipurpose hall.
4

Utiliza??o de um aplicativo de simula??o computacional na avalia??o de desempenho t?rmico de prot?tipo de habita??o de interesse social (his)

Oliveira, Rodrigo Porto 26 March 2010 (has links)
Made available in DSpace on 2014-12-17T13:57:01Z (GMT). No. of bitstreams: 1 RodrigoPO_DISSERT_1-86.pdf: 4545112 bytes, checksum: 1469a5c4c25aa35695d699dad3987af5 (MD5) Previous issue date: 2010-03-26 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO? Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Efici?ncia Energ?tica de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity / A presente disserta??o de mestrado teve como objetivo estudar comparativamente os dados das temperaturas do ar internas simuladas atrav?s de um aplicativo computacional de simula??o t?rmica, o DesignBuilder 1.2, e os dados registrados in loco atrav?s do HOBO? Temp Data Logger, em prot?tipo de Habita??o de Interesse Social (HIS), localizado no Campus Central da Universidade Federal do Rio Grande do Norte UFRN. O referido prot?tipo foi projetado e constru?do buscando estrat?gias de conforto t?rmico recomendadas para o clima do local de estudo, e constru?do com pain?is de concreto celular pela Construtora DoisA, interventora do projeto de pesquisa REPESC Rede de Pesquisa em Efici?ncia Energ?tica de Sistemas Construtivos, integrante do programa Habitare. A metodologia utilizada partiu da problem?tica, realizando uma revis?o bibliogr?fica, que levantou os principais aspectos relacionados ?s simula??es computacionais de desempenho t?rmico de edifica??es, como a caracteriza??o clim?tica da regi?o objeto de estudo e ?s exig?ncias de conforto t?rmico de usu?rios. O aplicativo computacional DesignBuilder 1.2 foi o utilizado como ferramenta de simula??o, realizando altera??es te?ricas no prot?tipo e comparando-os com os par?metros de conforto t?rmico adotados, com base na literatura t?cnica atual da ?rea. As an?lises dos resultados dos estudos comparativos foram realizadas atrav?s de sa?das gr?ficas para a compreens?o das amplitudes de temperatura do ar e situa??es de conforto t?rmico. Os dados utilizados para a caracteriza??o da temperatura do ar externa foi o Test Reference Year (TRY), definidos para a regi?o de estudo (Natal-RN). Neste sentido, tamb?m foram realizados estudos comparativos do TRY com os dados registrados nos anos 2006, 2007 e 2008, na esta??o clim?tica Davis Precision Station, localizada no Instituto Nacional de Pesquisas Espaciais INPE-CRN, em terreno cont?guo ao Campus Central da UFRN. Dos estudos comparativos entre as simula??es computacionais e os registros in loco realizados no prot?tipo objeto de estudo, conclui-se que simula??es em edifica??es naturalmente ventiladas ? uma tarefa complexa devido ?s limita??es dos aplicativos, principalmente devido ? complexidade do fen?meno de escoamento do ar, da influ?ncia das condi??es de contorno da ?rea e dos registros clim?ticos. Por fim, quanto ? utiliza??o do aplicativo DesignBuilder 1.2 no presente estudo, pode-se definir como uma boa ferramenta de simula??o computacional. Todavia, h? necessidade de alguns ajustes para maior confiabilidade na sua utiliza??o, tendo a necessidade de continua??o da pesquisa considerando a ocupa??o de usu?rios no prot?tipo, bem como as cargas t?rmicas de equipamentos, no sentido de aferi??o de sua sensibilidade
5

Simula??o computacional como ferramenta de aux?lio ao projeto: aplica??o em edif?cios naturalmente ventilados no clima de Natal/RN

Trindade, Sileno Cirne 08 December 2006 (has links)
Made available in DSpace on 2014-12-17T13:57:19Z (GMT). No. of bitstreams: 1 SilenoCT.pdf: 2677839 bytes, checksum: ab606ee9a9e47606999ca5cf548141a6 (MD5) Previous issue date: 2006-12-08 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study / A ventila??o natural se constitui no principal recurso passivo para obten??o do conforto t?rmico em climas quentes e ?midos, al?m de promover a redu??o do consumo energ?tico com condicionamento artificial. Entretanto, existem restri??es ao seu uso por parte dos arquitetos por n?o haver garantias de que ela possa resolver os problemas de conforto t?rmico, quando comparada aos sistemas artificiais. Nesse sentido, decidiu-se investigar formas de prever o comportamento da ventila??o natural atrav?s de ferramentas de simula??o computacional, visando auxiliar a decis?o arquitet?nica. O objeto de estudo ? o edif?cio pr?fabricado tipo galp?o devido ?s suas caracter?sticas geom?tricas e ? freq??ncia de uso na regi?o, especificamente no campus universit?rio central da UFRN. Foi utilizado um programa de din?mica de fluidos (Computational Fluid Dynamics - CFD) e um de simula??o do comportamento t?rmico e energ?tico de edifica??es (energy tool - ET). A pesquisa priorizou a discuss?o dos procedimentos necess?rios para viabilizar as an?lises da ventila??o em galp?es. Durante seu desenvolvimento, ? mostrado como o m?todo teve que ser adequado ? complexidade de sucessivas abordagens, resultando em simplifica??es e incertezas de resultados. Para exemplificar a abordagem s?o apresentados alguns resultados de simula??es. Ao final, as limita??es e potencialidades do m?todo s?o discutidas com base nas caracter?sticas dos c?digos de simula??es utilizados, das condi??es de simula??o e da representatividade dos modelos
6

O desempenho da compartimenta??o horizontal seletiva na promo??o da seguran?a contra inc?ndio em edifica??es

Cunha, Leonardo Jorge Brasil de Freitas 12 April 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-08-09T22:49:24Z No. of bitstreams: 1 LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-08-10T22:57:29Z (GMT) No. of bitstreams: 1 LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5) / Made available in DSpace on 2016-08-10T22:57:29Z (GMT). No. of bitstreams: 1 LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5) Previous issue date: 2016-04-12 / No trabalho apresentam-se os resultados da pesquisa que aborda o desempenho da compartimenta??o horizontal seletiva na promo??o da Seguran?a Contra Inc?ndio em Edifica??es - SCIE. A compartimenta??o horizontal ? uma medida de prote??o passiva de total controle por parte do arquiteto, pass?vel de ser definida logo nas primeiras fases do processo projetual. Contudo, nota-se uma cont?nua reconfigura??o dos ambientes em edifica??es acad?micas, objetivando ajust?-los ? demanda surgente por espa?o. Assim, um determinado ambiente concebido inicialmente como uma ampla sala de aula pode se transformar em duas ou mais salas menores, por exemplo. Independentemente do momento em que ocorre a subdivis?o, seja na fase de projeto ou durante a ocupa??o da edifica??o, as normas s? consideram o ambiente compartimentado quando s?o empregados os elementos classificados como corta-fogo. Entretanto, considerando que os minutos iniciais de um inc?ndio s?o os mais importantes na prote??o a vida, trabalhou-se a hip?tese de que uma forma de particionamento ignorado pelas prescri??es normativas ? capaz de favorecer a evacua??o e o resgate dos ocupantes ao promover exaust?o da fuma?a no ambiente incendiado. A partir de um modelo representativo de um ambiente acad?mico constru?do, utilizou-se a simula??o computacional para testar o desempenho de um tipo de compartimenta??o horizontal seletiva com diferentes combina??es de aberturas para exaust?o da fuma?a. Nos resultados obtidos demonstrou-se que a compartimenta??o horizontal seletiva ? capaz de promover benef?cios para os ocupantes durante a evacua??o, tanto por promover maior altura da camada livre de fuma?a, quanto por retardar o instante em que a temperatura limite para a sobreviv?ncia humana ? atingida. / The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room?s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.
7

Desenvolvimento de um simulador de bombeio por cavidades progressivas

Vidal, Francisco Jos? Targino 19 December 2005 (has links)
Made available in DSpace on 2014-12-17T14:55:57Z (GMT). No. of bitstreams: 1 FranciscoJTV.pdf: 1100058 bytes, checksum: 1324dc0f705af005f06ca71bee5c289c (MD5) Previous issue date: 2005-12-19 / The method of artificial lift of progressing cavity pump is very efficient in the production of oils with high viscosity and oils that carry a great amount of sand. This characteristic converted this lift method into the second most useful one in oil fields production. As it grows the number of its applications it also increases the necessity to dominate its work in a way to define it the best operational set point. To contribute to the knowledge of the operational method of artificial lift of progressing cavity pump, this work intends to develop a computational simulator for oil wells equipped with an artificial lift system. The computational simulator of the system will be able to represent its dynamic behavior when submitted to the various operational conditions. The system was divided into five subsystems: induction motor, multiphase flows into production tubing, rod string, progressing cavity pump and annular tubing-casing. The modeling and simulation of each subsystem permitted to evaluate the dynamic characteristics that defined the criteria connections. With the connections of the subsystems it was possible to obtain the dynamic characteristics of the most important arrays belonging to the system, such as: pressure discharge, pressure intake, pumping rate, rod string rotation and torque applied to polish string. The shown results added to a friendly graphical interface converted the PCP simulator in a great potential tool with a didactic characteristic in serving the technical capability for the system operators and also permitting the production engineering to achieve a more detail analysis of the dynamic operational oil wells equipped with the progressing cavity pump / O m?todo de eleva??o artificial por bombeio de cavidades progressivas tem se mostrado muito eficiente na produ??o de ?leos com alta viscosidade ou que carreiem uma grande quantidade de areia. Essa caracter?stica tem feito do mesmo o segundo m?todo de eleva??o mais utilizado nos campos de produ??o de petr?leo. ? medida em que aumenta o n?mero de suas aplica??es cresce tamb?m a necessidade de um maior dom?nio do conhecimento quanto ao seu funcionamento operacional, de maneira ? definir um ponto ?timo de opera??o. A fim de contribuir para a expans?o do conhecimento operacional do m?todo de eleva??o por bombeio de cavidades progressivas, este trabalho prop?e o desenvolvimento de um simulador computacional para po?os de petr?leo equipados com esse sistema, capaz de representar o comportamento din?mico do mesmo quando submetido ?s mais diversas condi??es operacionais. O sistema foi dividido em cinco subsistemas: motor de indu??o, escoamento multif?sico na coluna de produ??o, coluna de haste, bomba de cavidades progressivas e anular revestimento-coluna de produ??o. A modelagem e a simula??o de cada subsistema permitiram avaliar as caracter?sticas din?micas que definiram os crit?rios de acoplamento dos mesmos. Com a realiza??o do acoplamento foi poss?vel obter as caracter?sticas din?micas das principais vari?veis pertinentes ao sistema, tais como: press?o de recalque, press?o de suc??o, vaz?o da bomba, rota??o da coluna de haste e o torque aplicado ? haste polida. Os resultados apresentados, somados a uma interface gr?fica amig?vel, fazem do simulador de BCP uma ferramenta de grande potencial, tanto de car?ter did?tico, auxiliando na capacita??o t?cnica dos operadores do sistema, quanto para aux?lio na engenharia de produ??o, permitindo realizar uma an?lise mais detalhada da din?mica operacional dos po?os de petr?leo equipado com esse m?todo de eleva??o
8

Simula??o computacional do escoamento em bombas de cavidades progressivas

Pessoa, Paulo Alison Sousa 15 December 2009 (has links)
Made available in DSpace on 2014-12-17T14:57:56Z (GMT). No. of bitstreams: 1 PauloASP.pdf: 2445269 bytes, checksum: 158c07b839a3cc9c6803734bb383eed0 (MD5) Previous issue date: 2009-12-15 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The use of Progressing Cavity Pumps (PCPs) in artificial lift applications in low deep wells is becoming more common in the oil industry, mainly, due to its ability to pump heavy oils, produce oil with large concentrations of sand, besides present high efficiency when compared to other artificial lift methods. Although this system has been widely used as an oil lift method, few investigations about its hydrodynamic behavior are presented, either experimental or numeric. Therefore, in order to increase the knowledge about the BCP operational behavior, this work presents a novel computational model for the 3-D transient flow in progressing cavity pumps, which includes the relative motion between rotor and stator, using an element based finite volume method. The model developed is able to accurately predict the volumetric efficiency and viscous looses as well as to provide detailed information of pressure and velocity fields inside the pump. In order to predict PCP performance for low viscosity fluids, advanced turbulence models were used to treat, accurately, the turbulent effects on the flow, which allowed for obtaining results consistent with experimental values encountered in literature. In addition to the 3D computational model, a simplified model was developed, based on mass balance within cavities and on simplification on the momentum equations for fully developed flow along the seal region between cavities. This simplified model, based on previous approaches encountered in literature, has the ability to predict flow rate for a given differential pressure, presenting exactness and low CPU requirements, becoming an engineering tool for quick calculations and providing adequate results, almost real-time time. The results presented in this work consider a rigid stator PCP and the models developed were validated against experimental results from open literature. The results for the 3-D model showed to be sensitive to the mesh size, such that a numerical mesh refinement study is also presented. Regarding to the simplified model, some improvements were introduced in the calculation of the friction factor, allowing the application fo the model for low viscosity fluids, which was unsuccessful in models using similar approaches, presented in previous works / O uso de bombas de cavidades progressivas (BCP) para eleva??o artificial de petr?leo em po?os de baixa a m?dia profundidade est? se tornando mais comum na ind?stria do petr?leo devido, dentre outras caracter?sticas, ? sua habilidade de bombear ?leos pesados, produzir ?leo com grandes concentra??es de part?culas s?lidas, e tolerar grandes fra??es de g?s livre. Al?m disso, apresenta alta efici?ncia, quando comparado a outros sistemas de eleva??o artificial. Apesar de este sistema ser bastante utilizado na eleva??o de ?leo, poucas investiga??es acerca do seu comportamento hidrodin?mico podem ser encontradas na literatura. Desta forma, devido ? necessidade de obter um maior dom?nio do comportamento operacional da BCP, este trabalho apresenta um novo modelo computacional para escoamento 3-D transiente em bombas de cavidades progressivas, utilizando o m?todo dos volumes finitos baseado em elementos, no qual se inclui o movimento relativo entre o rotor e o estator. O modelo desenvolvido ? capaz de predizer com exatid?o par?metros operacionais, como efici?ncia volum?trica e perdas viscosas, assim como fornecer informa??es detalhadas dos campos de press?o e velocidade no interior da bomba. Para tornar poss?vel o estudo com BCP s bombeando fluidos de baixa viscosidade, foram utilizados modelos de turbul?ncia avan?ados para tratar adequadamente os efeitos turbulentos no escoamento, os quais permitiram obter informa??es coerentes com a literatura do comportamento da BCP em resultados experimentais. Al?m do modelo tridimensional, este trabalho apresenta um modelo simplificado baseado em um balan?o de massa entre as cavidades e na simplifica??o das equa??es do movimento para escoamento completamente desenvolvido ao longo das linhas de selo entre as cavidades. O modelo simplificado, baseado em abordagens j? utilizadas para este tipo de bomba, tem capacidade de predizer valores de vaz?o para um dado diferencial de press?o, apresentando exatid?o e requerendo pouco trabalho de CPU, tornando-se uma ferramenta de engenharia de uso f?cil, permitindo respostas num?ricas aproximadas em tempo-real. Os resultados apresentados neste trabalho consideraram uma BCP de estator r?gido e os modelos apresentados foram validados com resultados experimentais da literatura. Os resultados para o modelo tridimensional mostraram-se sens?veis ao tamanho da malha, de maneira que um estudo de refinamento de malha ? apresentado. J? no modelo simplificado foram introduzidos alguns melhoramentos no c?lculo do fator de atrito permitindo a aplica??o para fluidos de baixa viscosidade, o que n?o era poss?vel em modelos similares apresentados em trabalhos anteriores
9

Modos projetuais de simula??o: uso de ferramentas de simula??o t?rmica no processo projetual de arquitetura

Lima, Raoni Ven?ncio dos Santos 08 June 2012 (has links)
Made available in DSpace on 2014-12-17T13:56:51Z (GMT). No. of bitstreams: 1 RaoniVSL_TESE_CAPA_A_CAP 4.pdf: 3294621 bytes, checksum: 8a959519efff80a0112daae4f73d724f (MD5) Previous issue date: 2012-06-08 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This thesis aims to describe and demonstrate the developed concept to facilitate the use of thermal simulation tools during the building design process. Despite the impact of architectural elements on the performance of buildings, some influential decisions are frequently based solely on qualitative information. Even though such design support is adequate for most decisions, the designer will eventually have doubts concerning the performance of some design decisions. These situations will require some kind of additional knowledge to be properly approached. The concept of designerly ways of simulating focuses on the formulation and solution of design dilemmas, which are doubts about the design that cannot be fully understood nor solved without using quantitative information. The concept intends to combine the power of analysis from computer simulation tools with the capacity of synthesis from architects. Three types of simulation tools are considered: solar analysis, thermal/energy simulation and CFD. Design dilemmas are formulated and framed according to the architect s reflection process about performance aspects. Throughout the thesis, the problem is investigated in three fields: professional, technical and theoretical fields. This approach on distinct parts of the problem aimed to i) characterize different professional categories with regards to their design practice and use of tools, ii) investigate preceding researchers on the use of simulation tools and iii) draw analogies between the proposed concept, and some concepts developed or described in previous works about design theory. The proposed concept was tested in eight design dilemmas extracted from three case studies in the Netherlands. The three investigated processes are houses designed by Dutch architectural firms. Relevant information and criteria from each case study were obtained through interviews and conversations with the involved architects. The practical application, despite its success in the research context, allowed the identification of some applicability limitations of the concept, concerning the architects need to have technical knowledge and the actual evolution stage of simulation tools / Esta tese tem o objetivo de descrever e demonstrar o conceito desenvolvido para facilitar o uso de ferramentas de simula??o t?rmica durante o processo de projeto arquitet?nico. A despeito do impacto de elementos arquitet?nicos no desempenho de edifica??es, decis?es influentes s?o freq?entemente baseadas apenas em informa??es qualitativas. Apesar desse tipo de suporte ser adequado para boa parte das decis?es, o projetista ir?, eventualmente, ter d?vidas sobre algumas decis?es durante o projeto. Essas situa??es ir?o necessitar de informa??es adicionais para serem adequadamente abordadas. O conceito de modos projetuais de simula??o ? centrado na formula??o e resolu??o de dilemas de projeto, que s?o d?vidas de projeto que n?o podem ser satisfatoriamente compreendidas ou resolvidas sem o uso de informa??es quantitativas. O conceito busca combinar o poder de an?lise de ferramentas computacionais com a capacidade de s?ntese do projetista. Tr?s tipos de ferramentas s?o considerados: an?lise solar, t?rmica/energ?tica e CFD. Dilemas de projeto s?o formulados e enquadrados de acordo com o processo de reflex?o do arquiteto sobre aspectos de desempenho. Ao longo da tese, o problema ? investigado em tr?s diferentes esferas: profissional, t?cnica e te?rica. Essa abordagem de diferentes partes do problema buscou i) caracterizar diferentes categorias profissionais no que se refere ? pr?tica projetual e ao uso de ferramentas, ii) investigar trabalhos sobre o uso de ferramentas e iii) tra?ar analogias entre o conceito proposto e alguns conceitos e defini??es desenvolvidos em pesquisas sobre teoria de projeto. O conceito proposto foi aplicado em oito dilemas de projeto extra?dos de tr?s estudos de caso na Holanda. Os tr?s projetos investigados s?o resid?ncias, projetadas por escrit?rios de arquitetura holandeses. As informa??es e crit?rios mais relevantes de cada projeto foram obtidos atrav?s de entrevistas e conversas com os arquitetos envolvidos. A aplica??o pr?tica, embora bem sucedida no contexto da pesquisa, permitiu a identifica??o de limita??es de aplicabilidade do conceito, tanto no que diz respeito ? necessidade dos arquitetos de ter certo n?vel de dom?nio t?cnico quanto ao atual est?gio de evolu??o das ferramentas
10

An?lise de m?todos para aplica??o de ventila??o natural em projetos de edifica??es em Natal-RN

Cunha, Leonardo Jorge Brasil de Freitas 11 February 2010 (has links)
Made available in DSpace on 2014-12-17T13:57:01Z (GMT). No. of bitstreams: 1 LeonardoJBFC_DISSERT.pdf: 4968156 bytes, checksum: 1552078bbabf9200e90e9a2e93780139 (MD5) Previous issue date: 2010-02-11 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the C?digo de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained / A ventila??o natural ? uma estrat?gia bioclim?tica eficaz na promo??o do conforto t?rmico, da salubridade e no arrefecimento da massa edificada. Contudo, a despreocupa??o com a qualidade ambiental, as incertezas envolvidas no fen?meno e a populariza??o dos sistemas artificiais de climatiza??o costumam servir de argumento para os que negligenciam os benef?cios do condicionamento passivo. As incertezas podem ser reduzidas quando a ventila??o ? contemplada em todas as etapas de processo projetual, principalmente nas fases iniciais, na qual as decis?es t?m grande impacto no desempenho da edifica??o. As ferramentas dispon?veis para quantificar o impacto das decis?es projetuais consistem basicamente no c?lculo da taxa de renova??o ou na simula??o computacional de fluidos, comumente denominada CFD, sigla em ingl?s para din?mica computacional de fluidos , ambas com algum distanciamento da pr?tica do projeto e carentes de adapta??o para que possam ser utilizadas em estudos param?tricos. Assim, optou-se por verificar, atrav?s da simula??o computacional, a representatividade dos resultados obtidos com o m?todo de c?lculo simplificado da taxa de renova??o do ar, bem como torn?-lo mais compat?vel com as quest?es pertinentes ?s primeiras fases do processo projetual. O objeto de estudo consiste em um modelo resultante das recomenda??es do C?digo de Obras de Natal/ RN, cujas aberturas foram dimensionadas de acordo com a NBR 15220. A pesquisa mostrou a complexidade em agregar uma ferramenta CFD ao processo e a necessidade de um m?todo capaz de gerar dados na mesma velocidade com que as id?ias surgem e s?o descartadas durante o desenvolvimento do projeto. Ao final discute-se as concess?es necess?rias para a realiza??o das simula??es, a aplicabilidade e as limita??es tanto das ferramentas utilizadas quanto do m?todo adotado e a representatividade dos resultados obtidos

Page generated in 0.5234 seconds