1 |
SINGLE ENDED TRAVELING WAVE BASED FAULT LOCATION USING DISCRETE WAVELET TRANSFORMChang, Jin 01 January 2014 (has links)
In power transmission systems, locating faults is an essential technology. When a fault occurs on a transmission line, it will affect the whole power system. To find the fault location accurately and promptly is required to ensure the power supply. In this paper, the study of traveling wave theory, fault location method, Karrenbauer transform, and Wavelet transform is presented. This thesis focuses on single ended fault location method. The signal processing technique and evaluation study are presented. The MATLAB SimPowerSystem is used to test and simulate fault scenarios for evaluation studies.
|
2 |
Computational Pipeline for Human Transcriptome Quantification Using RNA-seq DataXu, Guorong 04 August 2011 (has links)
The main theme of this thesis research is concerned with developing a computational pipeline for processing Next-generation RNA sequencing (RNA-seq) data. RNA-seq experiments generate tens of millions of short reads for each DNA/RNA sample. The alignment of a large volume of short reads to a reference genome is a key step in NGS data analysis. Although storing alignment information in the Sequence Alignment/Map (SAM) or Binary SAM (BAM) format is now standard, biomedical researchers still have difficulty accessing useful information. In order to assist biomedical researchers to conveniently access essential information from NGS data files in SAM/BAM format, we have developed a Graphical User Interface (GUI) software tool named SAMMate to pipeline human transcriptome quantification. SAMMate allows researchers to easily process NGS data files in SAM/BAM format and is compatible with both single-end and paired-end sequencing technologies. It also allows researchers to accurately calculate gene expression abundance scores.
|
3 |
Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneosHerrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
|
4 |
Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneosHerrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
|
5 |
Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneosHerrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
|
6 |
Analýza dat ze sekvenování příští generace ke studiu aktivity transposonů v nádorových buňkách / Analysis of NGS data for study of transposon activity in cancer cellsHrazdilová, Ivana January 2013 (has links)
Theoretical part of this diploma thesis gives a brief characteristic of human mobile elements (transposons), which represents nearly 50% of human genome. It provides basic transposon clasification and describes types of transposons present in hunam genome, as well as mobilization, activation and regulation mechanisms. The work also deals with the domestication of transposons, describes the ways in which TE contribute to DNA damage and summarizes the diseases caused by mutagenic activity of transposons in the human genome. Conclusion of theoretical part describes next-generation sequencing technologies (NGS). As practical part, data from RNA-seq experimet were analyzed in order to compare differen transposon activity in normal and cancer cells from prostate and colorectal tissues. As like as publicly available sophisticated tools (TopHat), new scripts were created to analyze these data. The results show that cancer cells exhibit overexpression of transposons. This corresponds with the published results and suggests a connection of transposon activation with cancer development.
|
7 |
Spínané zdroje velkých výkonů - paralelní řazení zdrojů / High power switch-mode supplies - parallel connectionKadlec, Josef January 2016 (has links)
This doctoral thesis deals with the issue of high power switched-mode power supplies that are designed as modular systems. The thesis describes series, parallel and series-parallel possibility of connected converters. System can achieve extremely high output current for converters connected in parallel. For converters connected in series, the system can achieve extremely high output voltage. The main goal of this thesis is to develop so-called reconfigurable modular system. It is a system that can change converters connection of serial, parallel or series-parallel connection - during its operation. This option to change converters connection significantly extends the control range of output voltage and output current of the whole system. For all these mentioned variants of the modular system there are described and simulated suitable control schemes. The issue of interleaved PWM is described in the thesis. Output voltage ripple and current ripple equations were derived for each converters connection. These equations, which were derived either for systems with interleaved PWM or for systems without of phase shifted PWM, are also proved by simulations. Design of reconfigurable modular system with power of 9.6 kW that contains four converters was introduced in this thesis. Converters use modern transistors and diodes of SiC material. The proposed reconfigurable modular system was successfully manufactured. The measurement results are also shown in the work.
|
8 |
New Generation 4-Channel GNSS Receiver : Design, Production, and TestingAntoja Lleonart, Guillem January 2018 (has links)
Due to the current research needs and the lack of commercial multi-channel, multi-constellation GNSS receivers, a two-board solution has been developed so it can be mated with and take advantage of the processing power of the FPGA board branded as MicroZed. In order to achieve the proposed goals, an initial phase for assessing and updating the older design, building, and testing of SiGe modules (including both the electronics and casings) has been carried out. The results included demonstrate performances at logging GPS-L1 data with similar C/N0 and AGC values as the previous versions of the modules and offering navigation solutions with accuracies of a few meters. Secondly, a first iteration and design proposal for the new generation receiver has been proposed for GPS and GLONASS L1 and L2, which has been manufactured and tested. Partial tests have been performed due to the flaws of the current revision of the MicroZed Board in regards to its communication peripherals, and the results have validated the receiver’s design provided certain modifications are considered for future iterations. Furthermore, voltage and frequency tests have provided results with an error of less than 7%, and signal tests have provided C/N0 values similar to those of the SiGe modules of around 47[dB-Hz] which will be a useful baseline for future iterations. Finally, a design proposal for an Interface Board used between the older NT1065_PMOD Board and other FPGA boards carrying the standardized FMC connectors has been added to the report and negotiations with manufacturers have been engaged.
|
Page generated in 0.0764 seconds