• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 4
  • 3
  • 1
  • Tagged with
  • 195
  • 195
  • 126
  • 103
  • 101
  • 82
  • 49
  • 48
  • 38
  • 38
  • 35
  • 34
  • 33
  • 31
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Aplicação do protocolo SNMP para o monitoramento on line de uma microgeração fotovoltaica / Application of the SNMP protocol for on-line monitoring of a photovoltaic microgeneration

Santos, Francisco Sérgio dos [UNESP] 19 May 2017 (has links)
Submitted by FRANCISCO SÉRGIO DOS SANTOS null (fsergio.santos@gmail.com) on 2017-06-23T13:10:13Z No. of bitstreams: 1 TESE_FRANCISCO_SERGIO_DOS_SANTOS.pdf: 6603447 bytes, checksum: a50e5f7ef38c8d0f9877a04d8d72b92e (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-23T17:33:38Z (GMT) No. of bitstreams: 1 santos_fs_dr_bot.pdf: 6603447 bytes, checksum: a50e5f7ef38c8d0f9877a04d8d72b92e (MD5) / Made available in DSpace on 2017-06-23T17:33:38Z (GMT). No. of bitstreams: 1 santos_fs_dr_bot.pdf: 6603447 bytes, checksum: a50e5f7ef38c8d0f9877a04d8d72b92e (MD5) Previous issue date: 2017-05-19 / Rede de computadores são elementos fundamentais no processo de comunicação. Esses componentes exigem o acompanhamento constante de suas tarefas e são administrados por sistemas de informações que coletam os dados diariamente, para orientar os analistas de suporte na correção das falhas na infraestrutura e a ferramenta utilizada na gestão de recursos de rede de computadores é o protocolo SNMP. As infraestruturas de geração de energia elétrica também são elementos complexos e necessitam de acompanhamento. São utilizados sistemas de informação que disponibilizam dados para os usuários e responsáveis técnicos para avaliarem o funcionamento e corrigir as possíveis falhas. As redes de computadores e os sistemas de geração distribuídas estão convergindo para o ambiente do usuário, e as ferramentas de gestão são importantes são mecanismos na gestão da produção e consumo de energia elétrica. Assim, este trabalho tem como objetivo desenvolver um sistema de monitoramento on line para sistema de microgeração fotovoltaica utilizando o protocolo de rede de computadores Single Network Management Protocol (SNMP) para realizar a interface de comunicação com as variáveis de medições elétricas e meteorológicas. O desenvolvimento do projeto compõe dois componentes: hardware e software. O software é composto de dois módulos um para ser utilizado na Web, aplicações Desktop para uso em computadores que suportem sistemas operacionais como o Windows, Linux ou Mac e em dispositivos móveis. As funcionalidades programadas são cadastros das informações para o funcionamento do sistema, relatórios e gráficos que disponibilizam as informações ordenadas em vários níveis, diariamente, semanalmente, anualmente. Nos componentes de hardware foram utilizados cinco microcontroladores Atmel AVR, (Arduino) todos ligados à sensores e programados para a leitura de geração e consumo de energia elétrica e variáveis ambientais, como velocidade do vento, radiância solar, temperatura e níveis de chuva no período, e controle do sistema de bombeamento com duas motos bombas. Todos os experimentos foram realizados na central de microgeração distribuída fotovoltaica (MGD-PV) do Sítio Modelo da fazenda Lageado e no Laboratório de Energias Renováveis do Departamento de Engenharia Rural, nas Faculdades de Ciências Agronômicas da UNESP, campus de Botucatu. O laboratório de Energias Renováveis é o Servidor do sistema e as distâncias são muito variáveis entre todos os microcontroladores, de 32 metros a 260 metros e para realizar o processo de coleta dos dados nos diversos pontos e suprir essa distância foi necessário a construção e configuração de uma infraestrutura de comunicação baseada nas tecnologias ZigBee, para conectar os cincos microcontroladores. Os dados são coletados em intervalos regulares de cinco minutos, às variáveis ambientais são acompanhadas vinte e quatro horas por dia e às variáveis de geração de energia elétrica entre sete da manhã e dezessete horas da tarde. Os dados foram coletados entre setembro de 2016 e fevereiro de 2017. Os componentes de hardware e de software apresentaram rendimentos satisfatórios no processamento das informações através da interface criada pelo protocolo SNMP na comunicação e nas transmissões dos dados gerados pelos sensores, na configuração e mapeamento os objetos para construção da MIB para serem utilizados nas medições elétricas e variáveis ambientais. / Computer networks are fundamental elements in the communication process. Such components demand constant supervision of their tasks and are managed by information systems, which daily collect data to guide support analysts when correcting glitches in the infrastructure. Protocol SNMP is the tool used for managing resources of the computer network. The infrastructures of electric energy generation are also complex elements and require monitoring. Information systems are utilized, which provide data to users and technical professionals, so they can evaluate functioning and correct possible errors. Computer networks and systems of distributed generation are converging towards the user’s environment, so, management tools are important mechanisms in the control of production and consumption of electric energy. Thus, this work aims at developing an online monitoring system for photovoltaic microgeneration using the Single Network Management Protocol (SNMP) to perform the communication interface with the variables of electrical and metereological measurements. The project development is composed of two elements: hardware and software. The software consists of two modules: one to be used on the Web, Desktop apps for use in computers that can carry operational systems such as Windows, Linux or Mac and one to be used in mobile devices. Programmed functionalities include information register for the functioning of the system; reports and graphs that show information ordained in several levels, daily, weekly and annually. As to hardware, we used five microcontrolers Atmel AVR, (Arduino) connected to sensors and programmed for reading the production and consumption of electric energy as well as environmental variables, such as wind speed, solar radiance, temperature and rain levels during the period and control of the pumping system with two motor pumps. All experiments were carried out at the Distributed Photovoltaic Microgeneration Central (MGD-PV) on a Model Farm and at the Renewable Energies Laboratory of the Agronomy College at UNESP, in Botucatu. The Renewable Energies Laboratory is the server of the system and the distances among all microcontrolers vary from 32 to 260 meters. Therefore, in order to collect data from several locations and neutralize such distance, we needed to build and configure a communication infrastructure based on ZigBee technologies to connect the five microcontrolers. Data are collected during five-minute intervals; environmental variables are followed twenty four hours a day and the variables of electric energy production between 7am and 5pm. Data were collected between September 2016 and February 2017. Hardware and software components showed satisfactory performance at processing information through the interface created by the SNMP protocol regarding communication and transmission of the data generated by sensors as well as on the configuration and mapping objects for the construction of the MIB to be used in electrical measurements and environmental variables.
132

Análise da influência de diferentes estratégias de arrefecimento no desempenho e durabilidade de inversores de sistemas fotovoltaicos conectados à rede

Perin, Aryston Luiz January 2016 (has links)
Inversores de sistemas fotovoltaicos são equipamentos de eletrônica de potência que fornecem energia elétrica em corrente alternada (CA) a partir de uma fonte de energia elétrica em corrente contínua (CC), no caso, os módulos fotovoltaicos. Estes inversores quando em operação aumentam sua temperatura. Este aumento de temperatura é indesejável, porém é inerente ao seu funcionamento. Equipamentos eletrônicos possuem um limite seguro de temperatura de operação, acima do qual podem ocorrer instabilidades de operação, redução da vida útil ou até mesmo falha drástica. O conhecimento da eficiência de conversão elétrica e das perdas responsáveis pelo aquecimento é importante para o adequado dimensionamento de inversores quando aplicados em sistemas fotovoltaicos conectados à rede, assim como para o desenvolvimento do inversor como produto. Para proteção, para aumento da vida útil, para maior confiabilidade, para maior estabilidade e para maior segurança de operação de componentes, inversores possuem rotinas em seus algoritmos de controle com estratégias automatizadas dedicadas ao gerenciamento térmico. Estas rotinas de proteção e gerenciamento térmico, sempre quando acionadas, tendem a reduzir a capacidade de conversão de potência do inversor, seja pelo acionamento de um ventilador auxiliar, seja pelo deslocamento do ponto de operação em máxima potência. Fabricantes de inversores tratam deste assunto pelo termo “temperature derating” (em inglês) Esta tese apresenta um estudo relacionado a influência da temperatura sobre o desempenho de inversores fotovoltaicos conectados à rede. Avalia tipos de estratégias de gerenciamento térmico e proteção de uso corrente em inversores comerciais. Apresenta resultados de ensaios experimentais para determinação de parâmetros térmicos característicos dos inversores. Descreve um modelo preditivo da temperatura de operação em regime transiente. A partir da determinação experimental de parâmetros térmicos, o modelo preditivo de temperatura de operação foi implementado no software de simulação dinâmica para dimensionamento e avaliação de sistemas fotovoltaicos FVCONECT, desenvolvido no LABSOL/UFRGS, estando o mesmo apto para simular a operação e estimar perdas anuais de desempenho energético decorrentes das rotinas de gerenciamento térmico, dos seus efeitos e das limitações impostas durante a operação de inversores fotovoltaicos conectados à rede. Um dos resultados da simulação é a evolução da temperatura do inversor, permitindo avaliar a frequência e amplitude dos ciclos térmicos ao qual o inversor é submetido e, consequentemente, determinar uma estimativa para durabilidade do inversor. / Photovoltaic inverters are electronic power devices that provide electrical energy in alternating current (AC) from a source of electrical energy in direct current (DC) - a photovoltaic generator, in this case. Inverters increase their temperature when in operation. This rise in temperature is not desirable, but inherent to its operation. Any electronic equipment has a safe operating temperature limit. When this limit is surpassed, operating instability, life reduction or even drastic failure may occur. The knowledge of the electrical conversion efficiency and the losses responsible for the heating is important for the proper sizing of grid-tie inverters in photovoltaic systems, as well as for the development of the inverter as a product. In order to increase the useful life of the device and its components, for greater reliability, safety, stability and security of operation, inverters have routines in their algorithms of control with automated strategies dedicated to the thermal management. These protection and thermal management routines, whenever activated, tend to reduce the power conversion capacity of the inverter, either by the activation of an auxiliary fan or by the displacement of the operating point at maximum power. Inverter manufacturers address this issue by the term "temperature derating". This thesis presents a methodology to evaluate the influence of the performance of different strategies to avoid excessive temperature of the inverter components on its performance and durability It is also made an evaluation of different thermal management strategies and protection used in commercial inverters. Results of experimental tests for determination of thermal parameters characteristic of the inverters are presented. A predictive model of transient operating inverter temperature is also described. From the experimental determination of thermal parameters, the predictive model of operating temperature was implemented to the FVCONECT, a dynamic simulation software for sizing and evaluation of photovoltaic systems developed in LABSOL / UFRGS. With this modification, the software was able to simulate the operation and estimate losses of energy due to the thermal management routines, their effects and the limitations imposed during the operation of grid-tie inverters. One of the results of the simulation is the evolution of the inverter temperature, allowing to evaluate the frequency and amplitude of thermal cycles to which the inverter is subjected and, as a consequence, an estimate of durability of the inverter.
133

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
134

Desenvolvimento de metodologia para avaliação do potencial de utilização de sistemas de energia solar fotovoltaica em meios urbanos

Torres, Rafael Gerzson January 2015 (has links)
Este trabalho visa desenvolver uma metodologia, através de ferramentas computacionais de simulação, de avaliação de mapas solares para a análise de sombreamentos e da radiação solar incidente sobre as coberturas e telhados das edificações dentro do ambiente urbano e aplicá-la para a cidade de Porto Alegre. Desta forma é possível identificar os melhores espaços para alocar futuras instalações fotovoltaicas e evitar possíveis perdas por sombreamento ao longo do ano. Para tanto, foram selecionadas quatro regiões de estudo, cada uma representando uma tipologia de bairro e edificações. Os bairros Centro Histórico, São Geraldo, São Sebastião e Santana foram selecionados por representarem: edificações comerciais de escritórios, galpões comerciais (depósitos e oficinas), residencial de baixa altura e prédios residenciais, respectivamente. Após o desenvolvimento dos mapas solares, são realizadas estimativas para capacidade de instalação e produção de energia elétrica por sistemas fotovoltaicos em cada edificação. O software EnergyPlus produziu modelos termoenergéticos para quatro edificações típicas representando cada uma das regiões de estudo e, assim, proceder um balanço de energia em escala anual para o consumo energético e a produção de energia. Considerando as hipóteses de simulação e premissas de cálculo utilizadas, verifica-se que existe potencial para a geração distribuída de energia em escala urbana para as regiões de estudo. Um resultado significativo ocorreu para a região do bairro São Geraldo, onde as dez maiores áreas de telhado equivalem a 53% do potencial total de instalação fotovoltaica aplicada a edificações da região de estudo. Ainda, realizado o balanço de energia, foram analisados os cenários de investimento para cada tipologia de edificação típica, resultando em um retorno sobre o investimento entre 9 e 13 anos, dependendo do tipo de edificação. / This work aims to develop a methodology, through computer simulation tools, for evaluating solar maps for shading analysis and incident solar radiation on the building roofs within the urban environment. This methodology is applied in the city of Porto Alegre. Thus, it is possible to identify the best areas to allocate future photovoltaic systems and avoid possible shading losses throughout the year. Therefore were selected four study areas, each one representing one type of neighborhood and respective buildings. The neighborhoods Centro Histórico, São Geraldo, São Sebastião and Santana were selected because they represent: commercial/office buildings, warehouses/workshops, low-rise residential and residential buildings, respectively. After the development of solar maps, estimates were made for the capacity of installation and the electric energy produced by photovoltaic systems in each building roof. The EnergyPlus software produced an energy model for a typical building of each study area (neighborhood) and make an energy balance in annual scale for the energy consumption and energy production. Considering the simulation hypothesis and assumptions, it appears that there is potential for the distributed generation in urban scale for the four study areas. A significant result was found for the São Geraldo region, where only the top ten building roof areas equals to 53% of the total potential of building applied photovoltaic in the respective neighborhood region. Also, performing the energy balance, investment scenarios were analyzed for each typical building, resulting in a return on investment between 9 and 13 years, depending on the building type.
135

Caracterização da geração distribuída de eletricidade por meio de sistemas fotovoltaicos conectados à rede, no Brasil, sob os aspectos técnico, econômico e regulatório / Characterization of the Distributed Generation of electricity by Grid-Connected Photovoltaic Systems in Brazil, with respect to technical, economic and regulatory aspects.

Ricardo da Silva Benedito 29 October 2009 (has links)
Este trabalho caracteriza a Geração Distribuída de eletricidade, no Brasil, por meio de Sistemas Fotovoltaicos Conectados à Rede (SFCR), a partir de aspectos técnicos, econômicos e regulatórios. O país possui, atualmente, 35 SFCR em operação, totalizando uma potência instalada de 161,32 kWp. A maior parte dessa potência se encontra nas Regiões Sul e Sudeste e foi implementada por universidades, centros de pesquisa e concessionárias de energia elétrica, com uma pequena participação da iniciativa privada. Foi calculado o custo de geração, a partir da energia solar, utilizando-se SFCR, para dezesseis localidades estrategicamente selecionadas. Esse valor varia em função da maior ou menor disponibilidade do recurso solar e da taxa de desconto adotada, tendo sido encontrado o valor médio de US$ 0,56 /kWh, cerca de 2,1 vezes maior que a tarifa residencial média nas mesmas cidades. Argumentando-se que a tarifa convencional tende a crescer nos próximos anos, pressionada pelo descompasso entre oferta e demanda, e que o custo de geração fotovoltaico tende a diminuir, no mesmo período, devido a ganhos de produtividade no processo de fabricação de componentes fotovoltaicos, elaborou-se um modelo matemático para prever o momento em que esses dois indicadores equiparar-se-ão. Verificou-se que o tempo médio de equiparação será de 7 anos, podendo ser menor que 5,0 anos em localidades onde a tarifa é mais cara que a média nacional e a irradiação média anual é superior à verificada no restante do país. Por fim, o trabalho analisa o enquadramento que a legislação faz dos geradores fotovoltaicos interligados à rede pública de distribuição, apontando os pontos favoráveis e os entraves legais à disseminação dos SFCR. / This work characterizes the Distributed Generation of electricity from Grid-Connected Photovoltaic Systems (GCPS) in Brazil, according to technical, economic and regulatory aspects. The country currently has 35 GCPS in operation, totaling an installed power of 161.32 kWp. Most of this power is in the South and Southeast and has been implemented by universities, research centers and electric power utilities, with a small participation of private initiative. The solar energy generation cost from GCPS was calculated for sixteen strategically selected localities. This value varies varies according to the greater or minor availability of the solar resource and the adopted discounting rate. The average value found was 0.56 US$ /kWh, about 2,1 times bigger than the average residential tariff in the same cities. Arguing that the conventional tariff tends to grow in coming years, pressed by the imbalance between supply and demand, and that the cost of photovoltaic generation tends to decrease over the same period due to productivity gains in the manufacturing process of photovoltaic components, a mathematical model was developed to predict the time that these two indicators will be equal. It was found that the average time of equalization will be 7.0 years and may be less than 5.0 years in locations where the conventional energy is more expensive than the national average and average annual irradiation is higher than that in the rest of the country. Finally, this work presents how the Brazilian legislation deals with the photovoltaic generators connected to the public distribution network, showing the points for and legal obstacles to the dissemination of GCPS.
136

Análise de um mecanismo de compensação de reativos incorporado aos inversores de um sistema fotovoltaico conectado à rede elétrica / Analysis of a reactive power compensation mechanism incorporated into inverters of a grid-connected photovoltaic system

Ricardo da Silva Benedito 14 November 2014 (has links)
No Brasil, quando uma unidade consumidora (UC) sob regime de microgeração ou de minigeração distribuída tem parte ou a totalidade da sua demanda por potência ativa suprida pela planta geradora, mas sua demanda por potência reativa é atendida exclusivamente pela rede elétrica, verifica-se uma aparente deterioração do fator de potência dessa UC, sob a ótica da concessionária. Esse efeito decorre do fato de que o fator de potência, de acordo com a regulamentação vigente, é determinado apenas a partir das medições dos fluxos de potência ativa e reativa trocados entre a UC e a rede elétrica e não também entre a planta geradora e UC. Para consumidores do Grupo A (tensão de fornecimento igual ou superior a 2,3 kV) nessa situação, de acordo com o perfil da carga, pode haver cobrança por excedentes de reativos, constituindo-se assim uma barreira. Especificamente no caso de sistemas fotovoltaicos conectados à rede, existe a possibilidade de se utilizar os próprios inversores c.c.-c.a para suprir a demanda de reativos da UC e, dessa forma, minimizar o problema apresentado. Com o objetivo de se avaliar essa alternativa no contexto brasileiro, tendo-se em vista condições reais de operação e os limites normativos de injeção de potência reativa para inversores de sistemas fotovoltaicos, foi realizado um estudo de caso de uma planta fotovoltaica instalada no telhado do prédio da Administração do Instituto de Energia e Ambiente da Universidade de São Paulo. O estudo mostrou que a compensação realizada por meio do inversor selecionado evitou a cobrança de excedentes de reativos sem afetar de forma significativa a produtividade do sistema fotovoltaico. Do ponto de vista elétrico, verificou-se que a injeção de reativos pelo inversor não provocou variações significativas de tensão no ponto de acoplamento ou no alimentador e, ainda, se verificou considerável liberação de capacidade do sistema supridor da concessionária. Dessa forma, a análise dos resultados indica uma tendência a se considerar a compensação de reativos proporcionada pelo próprio inversor a opção mais viável para se lidar com os excedentes de reativos, comparativamente a métodos convencionais de compensação ou à situação em que nenhuma ação compensatória seja implementada. / In Brazil, when a consumer unit (CU) under a distributed microgeneration or minigeneration scheme has part or all of its demand for active power supplied by the generating plant, but its demand for reactive power is served exclusively by the grid, the power factor of this CU appears deteriorated, from the perspective of the utility. This effect is due to the fact the power factor, according to the current regulations, is determined only from measurements of the flows of active and reactive power exchanged between the UC and the grid and not also between the generating plant and UC. Users of group A (supply voltage equal to or greater than 2.3 kV) in this situation, according to the CU load profile, may be charged due the reactive power excess, thus constituting a barrier. Specifically in the case of grid-connected photovoltaic systems, there is the possibility of using the d.c.- a.c. inverters to suply the CU reactive power demand and, thus, minimizing the presented problem. In order to evaluate this alternative in the Brazilian context, keeping in view real operating conditions and regulatory limits for the reactive power injection for photovoltaic inverters, we conducted a case study with a photovoltaic plant installed on the roof of the University of São Paulo Institute for Energy and Environment administration building. The study showed that the compensation performed by the selected inverter prevented the reactive power excess charging without affecting significantly the photovoltaic system productivity. From an electrical point of view, it was found that the injection of reactive power by the inverter did not cause significant voltage variations at the coupling point or at the transformer and, additionally, there was a significant release in the utility suply system capacity. Thus, the analysis results indicates a tendency to consider the compensation provided by the inverter itself the most viable option for dealing with the surplus of reactive power compared to conventional compensation methods or to the situation in which no compensatory action is implemented.
137

Implementação de infraestrutura laboratorial para análise operacional e capacitação em sistemas híbridos para geração de eletricidade / Implementation of Laboratory Infrastructure for Operational Analysis and Capacity Building in Hybrid Systems for Electricity Generation,

Kauê José Felipe Novaes Candido de Souza 24 May 2018 (has links)
Este trabalho apresenta o processo de ampliação da infraestrutura laboratorial de minirredes e sistemas híbridos do Laboratório de Sistemas Fotovoltaicos do Instituto de Energia e Ambiente da Universidade de São Paulo, (LSF-IEE/USP). O trabalho também contempla uma revisão do estado da arte de sistemas híbridos e minirredes, apresentando principalmente os aspectos técnicos, como formas de acoplamento, e interações com a rede elétrica de distribuição. Descrevem-se os sistemas híbridos presentes no LSF e a infraestrutura para sua interconexão. Posteriormente são realizados os processos de comissionamento e testes operacionais da interconexão dos sistemas híbridos entre si e com a rede elétrica. Ao final é proposto um curso de aperfeiçoamento em minirredes e sistemas híbridos utilizando a infraestrutura presente no LSF. / This work presents the expansion of the micro-grid and hybrid systems infrastructure at the Laboratory of Photovoltaic Systems of the Institute of Energy and Environment at the University of São Paulo (LSF-IEE / USP). The work also presents a review of the state of the art of hybrid systems and micro-grid, presenting mainly the technical aspects, such as types of system interconnections and interactions with the main grid. The hybrid systems existent in the LSF, as well as the infrastructure for their interconnection are described. Subsequently, the commissioning process and the operational tests with the interconnection of the hybrid systems with each other and with the main grid are performed. At the end, a capacity building course on micro-grids and hybrid systems using the existent infrastructure in the LSF is proposed.
138

Considerações sobre a fabricação nacional de módulos fotovoltaicos / Considerations about Brazilian domestic photovoltaics modules manufacturing

Daniel Nascimento Vivacqua 26 September 2016 (has links)
Este trabalho buscou entender a situação da atividade de fabricação de módulos fotovoltaicos no Brasil com o objetivo de avaliar a possibilidade de estimular a indústria nacional e o uso dessa fonte alternativa mais acentuadamente. Para tanto, foi necessário analisar os benefícios energéticos e econômicos da cadeia de produção, além de entender o estado da arte atual de todo o processo. É um ramo industrial que está sendo implantado no Brasil e este estudo teve como objetivo obter informações relevantes dos problemas e facilidades que os empreendedores enfrentam, e quais são os custos e benefícios à sociedade em geral, inclusive para obtenção dos sistemas fotovoltaicos pelo consumidor final. O trabalho contém uma avaliação do estado da produção e utilização dos sistemas de energia solar fotovoltaica no mundo e o que ocorre no Brasil. Buscou-se conhecer as possíveis, e/ou mais relevantes, ações regulatórias e iniciativas da área privada para viabilizar este ramo industrial. São considerados os impactos da atividade em pauta, procurando mostrar as relações de custo-benefício em projetos de geração centralizada (Leilões de Energia de Reserva) e de geração distribuída. / This study aims to understand the status of the manufacturing activity of photovoltaic modules in Brazil to evaluate the possibility of stimulating the local production and its widespread use. It was necessary to evaluate the energetic and economic benefits of the production chain. In addition, the study focused the understanding of the current state of the art of the whole process. Photovoltaic solar energy is an industrial branch recently receiving impulse in Brazil. This study aims to obtain relevant information about the difficulties faced by the entrepreneurs and the benefits and costs to the society. The study assess the state of the production and use of solar PV systems in the world and what happens in Brazil. At this study, we sought to understand what are the possible, and/or more relevant, regulatory actions and private area initiatives to enable this industrial branch and its diffusion to the final consumers. The impacts of the related activity are considered, trying to show the cost-benefit relationship in centralized generation projects (Reserve Energy Auctions) and distributed generation.
139

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
140

Proposta de implementação de seguidor solar considerando condições nubladas

Bellini, Douglas January 2017 (has links)
Orientadora: Profa. Dra. Ahda Pionkoski Grilo Pavani / Coorientador: Prof. Dr. Ricardo da Silva Benedito / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Energia, Santo André, 2017.

Page generated in 0.0918 seconds