81 |
Experimentální studium využití sondových metod pro diagnostiku nízkoteplotního zamagnetovaného plazmatu / Experimental study of the use of probe methods for diagnostic of low-temperature magnetized plasmaZanáška, Michal January 2015 (has links)
The ball-pen probe is a relatively new diagnostic method, that has been designed for direct measurement of plasma potential in magnetized plasmas. Nowadays, it is routinely used at several high-temperature plasma devices in Europe and it has been tested also in conditions of low-temperature plasma, which are substantially different from that of high-temperature plasma. The measurements performed so far showed, that ball-pen probe could be used also in low-temperature plasma. However, more measurements were needed to prove the applicability of ball-pen probe. Therefore, the main aim of this work is to compare the method of ball-pen probe with simultaneous measurements using Langmuir and emissive probe. Measurements were performed in DC discharge of cylindrical magnetron at various discharge conditions and radial positions of probes. Powered by TCPDF (www.tcpdf.org)
|
82 |
Studium sondových diagnostik okrajového plazmatu v tokamaku pomocí počítačových simulací / Study of probe diagnostics of tokamak edge plasma via computer simulationPodolník, Aleš January 2019 (has links)
The aim of the thesis is to examine plasma-wall interaction using computer modeling. Tokamak- relevant plasma conditions are simulated using the particle-in-cell model family SPICE working in three or two dimensions. SPICE model was upgraded with a parallel Poisson equation solver and a heat equation solver module. Plasma simulation aimed at synthetic Langmuir probe measurements were performed. First set considered a flush-mounted probe and the effect of variable magnetic field angle was studied with aim to compare existing probe data evaluation techniques and assess their operational space, in which the plasma parameters estimation via fit to the current-voltage characteristic is accurate. Second simulation set studied a protruding probe pin. Effective collecting area of such probe was investigated with intentions of density measurement collection. This area was found to be influenced by a combination of two factors. First, the density dampening inside the magnetic pre-sheath of the probe head, and the second, the extension of the area caused by Larmor rotation. A comparison with experimental results obtained at COMPASS tokamak was was performed, confirming these results. Keywords Langmuir probe, simulation, particle-in-cell, tokamak, Poisson equation, COMPASS 1
|
83 |
Diagnostika technologického plazmatu / Diagnostics of plasmas for technological applicationsTurek, Zdeněk January 2020 (has links)
The subject of the master thesis is the extension of the measurement of plasma para- meters by the Langmuir probe in a system with a planar magnetron and a hollow cathode operating in pulse mode. The main tasks are to modify the measuring circuit to increase the maximum probe current and to put the USB oscilloscope into operation for data collection with higher resolution and higher sampling rate. Furthermore, the function of the entire device will be verified using test circuits and also by measuring the probe characteristics in discharges in a system with a magnetron and a hollow cathode in both continuous and pulse mode. 1
|
84 |
Termodynamická metoda stanovení účinnosti vodního stroje. / Thermodynamic method for assessing hydraulic machine efficiencyMizera, Ladislav January 2011 (has links)
The master´s thesis contained basic information about the method of thermodynamic efficiency of hydraulic machines. The first part briefly mentioned our opinion on the most widely used method for determining the efficiency of hydraulic machines. Another section of thesis is characterization and measurement procedure using the thermodynamic method. Another section describes measurements of water plants and laboratory measurements, which took place in the past. The final part describes the results of laboratory measurements, which took place in the lab of VUT FSI Brno, and evaluating and comparing the results.
|
85 |
Agreagační chování polysacharidů ve vodných roztocích / Aggregation Behaviour of Polysaccharides in Aqueous SolutionsMravec, Filip January 2008 (has links)
Tato práce je zaměřena na agregační chování nativního a hydrofobně modifikovaného hyaluronanu, v různých molekulových hmotnostech a stupních substituce, ve vodném prostředí. Pro studium bylo vybráno šest fluorescenčních sond s různými vlastnostmi (Pyren; Nilská červeň; Perylen; Akridinová oranž; 6-(p-Toluidino)-2-nafthalenesulfonová kyselina; PRODAN). a výsledky získané pomocí těchto sond byly porovnány s jednoduchým anionaktivním tenzidem (Dodecylsíran sodný). U všech použité sond byly testovány jejich spektrální vlastnosti v závislosti na polaritě okolí a/nebo na koncentraci. Pro stanovení vlastností nepolárního jádra hyaluronového agregátu byly vybrány dvě sondy (Pyren, Nilská červeň). U domén byly sledovány polarita a viskozita vnitřního prostředí a jejich závislost na iontové síle a teplotě. Pro modifikované hyaluronany bylo stanoveno, že jejich kritická agregační koncentrace klesá s rostoucí molekulovou hmotností a stupněm substituce. Pro vlastní doménu platí, že její kompaktnost roste s rostoucí iontovou silou, ale klesá s rostoucí teplotou.
|
86 |
Aspectos cinéticos, estructurales y de reactividad de los dianiones de bifenilo y tetrafenilenoBlasco, Inmaculada 22 July 2016 (has links)
En la presente memoria se aborda el estudio de la reactividad de dianiones de hidrocarburos aromáticos policíclicos (HAPs). En el capítulo I se llevó a cabo una síntesis eficaz del fluorometilciclopropano y posterior estudio como sonda de radicales. Se estudió el mecanismo de reacción a través del cual tiene lugar la alquilación de dianiones de HAP (bifenilo y naftaleno) con fluoruros de alquilo primarios, con el fin de elucidar si este mecanismo transcurre vía TE, o si existe competencia con la sustitución nucleófila bimolecular SN2. En el capítulo II se ha conseguido establecer una ruta eficaz para la síntesis asimétrica del 2,7,10,15-tetra-terc-butiltetrafenileno, obteniendo ambos enantiómeros con excelentes excesos enantioméricos. Se ha llevado a cabo un estudio cinético para el cálculo de la energía de racemización del 2,7,10,15-tetra-terc-butiltetrafenileno.
|
87 |
Charakterizace nově vyvinutých fluorescenčních sond v buněčných systémech / Characterization of newly developed fluorescence probes in cellular systemsKadlecová, Julie January 2021 (has links)
Nanoparticles (NP) are currently a progressive area of scientific research. The possibility of synthesizing them according to the required parameters opens up possibilities for their wide use also in biomedicine. One example is a nanoparticle that can detect cellular processes, such as pH. We already know that the pH of healthy and cancer cells differs by the opposite gradient on the intracellular and extracellular side of the membrane. In this context, this work deals with the study of fluorescent silicon nanoparticles (SiNP) tested on a human keratinocyte cell line from a healthy donor (HaCaT) and from skin cancer donor (A431). Once found that even the highest concentrations of SiNP used are not cytotoxic, they can be further studied by fluorescence, confocal and super-resolution microscopy. In order to assess the pH detection properties of these SiNPs, a method for measuring intracellular pH with a fluorescent raciometric probe SNARF-1 using fluorescence spectroscopy and flow cytometry was introduced. Since the pH values of the intracellular environment are closely related to cellular metabolism, the metabolism of A431 and HaCaT cells was characterized and compared. To do this, methods for measuring analog glucose consumption (2-NBDG) and another new method for measuring real-time metabolism...
|
88 |
Riego de precisión para la eficiencia hídrica en la agricultura MediterráneaMartínez Gimeno, María Amparo 02 September 2020 (has links)
Tesis por compendio / [EN] The present Doctoral Thesis is framed around the three axes of the efficient irrigation: water distribution system selection, determination of irrigation water needs and plant water status assessment.
The experiment detailed in Chapter II is focused on the selection of the drip irrigation system better adapted to the peculiarities of citrus crops. The possible advantages of subsurface drip irrigation and the installation of irrigation laterals with higher density of emitters per plant were evaluated. Specifically, in the study was assessed the performance of the mandarin (Citrus clementina, Hort. Ex Tan. 'Arrufatina') under a surface (SI) and subsurface drip irrigation (SSI) with 7 (SI7, SSI7) or 14 emitters (SI14, SSI14) per plant, as well as a third SS treatment (SSIA), identical to SSI7 but equipped with an additional drip line buried between the tree rows. Treatments were assessed in terms of yield, fruit composition, water productivity (WP) and water savings. Results showed that, on average, water savings were 23.0% in the SSI treatment compared to the SI treatment without significant differences in either yield or fruit composition. SSIA was the treatment with the lowest irrigation volumes and the highest yield.
Chapter III proposes a methodology for estimating irrigation water needs for mandarins based on the use of capacitance water content probes (e.f. FDR). The calculation procedure is defined in three sequential parts: i) soil water content thresholds determination adapted to plants requirements for different phenological stages; ii) standardizing measurements from capacitance probes by using a hydrological simulation software to minimize equipment uncertainty; and finally iii) an extrapolation procedure for adapting critical soil water content thresholds to different soil conditions. Validating this strategy in a citrus orchard (Citrus clementina, Hort. Ex Tan. 'Arrufatina') a water saving of 26% was reached without significant differences in yield and increasing the WP by 33%.
In the experiments described in the Chapter IV a leaf turgor pressure sensor (Yara ZIM-probe) was evaluated as plant water status indicator in order to further asses the possibility to implement water status determinations in a more holistic irrigation scheduling approach. This technology, through a patch of an intact leaf and a pressure transductor, provides a signal (Pp) which is inversely correlated with the turgor pressure. The first experiment was made in Persimmon trees (Diospyros kaki L.f.). The turgor pressure sensor was assessed in an experimental plot with different irrigation doses and rootstocks with different drought tolerance [Diospyros lotus (L) and Diospyros virginiana (V)]. The information provided by the sensor was compared with concomitant measurements of midday stem water potential (¿stem) and trunk diameter variations. Three states of leaf turgor associated with specific plant water status were established from the study of the Pp signal evolution together with the ¿stem. Persimmon trees exhibited the inversed Pp curve phenomena under water stress (maximum values at night). Using the information from the sensors, it was possible to differentiate plant water status between rootstocks, pointing L as the most sensitive to the water deficit. The second experiment was made in mandarin (Citrus clementina, Hort. Ex Tan. 'Arrufatina'). Similarly, Pp values were compared with ¿stem measurements. In this case, the curves practically did not suffer inversions when the plant water status was inadequate, but an increase in the minimum and maximum Pp values was recorded at night and at noon, respectively. There was a good correlation between the concomitant hourly spot measurements of ¿stem and Pp that were taken at midday during two drought periods (coefficient of determination, r2 = 0.40 - 0.74). The analysed strategies and technologies have demonstrated that water
use efficiency can be optimized at the plot level. Consumptive water use can
be reduced using subsurface irrigation systems, achieving net savings in water
consumption. By estimating the irrigation dose by means of capacitance soil
water content probes, the efficiency in the application of the irrigation is improved and the water losses due to deep percolation are reduced,
minimizing the leaching of nutrients and with it, the risk of aquifer
contamination. In any case, it would be advisable to study the viability of these
proposals in the global and integral context of water resources management
at watershed and irrigation district level. / [ES] La presente Tesis Doctoral se enmarca en torno a los tres ejes que requiere cualquier riego para considerarse eficiente: 1) selección del sistema de distribución de agua, 2) determinación de las necesidades de riego y 3) control del estado hídrico de la planta.
El ensayo detallado en el Capítulo II se centró en la selección del sistema de riego por goteo que mejor se adaptara a las particularidades del cultivo de los cítricos. Se estudió la respuesta productiva de mandarino (Citrus clementina, Hort. Ex Tan. 'Arrufatina') en función de diversos sistemas de riego superficial (SI) y subterráneo (SSI) con 7 (SI7, SSI7) y 14 emisores (SI14, SSI14) por planta dispuestos en doble línea, así como un tercer tratamiento subterráneo (SSIA), idéntico a SSI7, pero equipado con una línea adicional subterránea situada entre filas de árboles. Los resultados mostraron que el ahorro de agua empleando el sistema SSI, en comparación con SI, puede llegar a ser del 23% sin mermas en la producción ni en la calidad de la fruta, incrementando por lo tanto la WP. El sistema SSIA fue el tratamiento que empleó menor volumen de agua de riego y obtuvo mayor rendimiento productivo.
En el Capítulo III se propone una metodología de cálculo de las necesidades de riego para mandarinos basada en el uso de sondas de humedad de tipo capacitivo (e.f. FDR). El procedimiento de cálculo se define en tres fases secuenciales: i) determinación de umbrales de humedad de suelo adaptados a los requerimientos de las plantas en distintas fases fenológicas; ii) estandarización de las lecturas de las sondas capacitivas mediante un programa de simulación hidrológica que permita reducir los efectos de la variabilidad intrínseca de los equipos; y, por último, iii) un procedimiento para extrapolar los umbrales de humedad definidos en el trabajo a cualquier parcela con distintas características edáficas. La validación de esta estrategia en una parcela de cítricos (Citrus clementina, Hort. Ex Tan. 'Arrufatina') supuso un ahorro de agua del 26% sin reducciones significativas en la producción, mejorando la WP un 33%.
En los ensayos descritos en el Capítulo IV se realiza la evaluación de los sensores de turgencia de hojas (Yara ZIM-probe) como indicadores del estado hídrico de la planta. Un primer experimento se realizó en caqui (Diospyros kaki L.f.), evaluando los sensores de turgencia en un ensayo de campo con distintas dosis de riego y portainjertos con diferente tolerancia a la sequía [Diospyros lotus (L) y Diospyros virginiana (V)]. La información que proporcionaba el sensor se comparó con medidas de potencial hídrico de tallo al mediodía solar (¿stem) y variaciones del diámetro del tronco. La evolución del Pp junto con los valores de ¿stem, permitió establecer tres estados de turgencia asociados a estados hídricos concretos. Los árboles insuficientemente regados con ¿stem por debajo de los -0.8 MPa, mostraron curvas Pp con signos de inversión (valores máximos durante la noche). Así mismo, con la información procedente de los sensores, fue posible diferenciar el estado hídrico entre patrones, señalando a L como el portainjerto más sensible al déficit hídrico. El segundo experimento se realizó en mandarino (Citrus clementina, Hort. Ex Tan. 'Arrufatina'). Del mismo modo, los valores de Pp se compararon con las medidas de ¿stem. En este caso, las curvas prácticamente no sufrieron inversiones cuando el estado hídrico de la planta era inadecuado, pero sí se determinó un aumento de los valores de Pp mínimos y máximos registrados por la noche y al mediodía, respectivamente. Así mismo, se realizaron dos ciclos de medidas horarias que mostraron que existe una buena correlación entre Pp y ¿stem (coeficiente de determinación, r2 = 0.40 - 0.74). Las estrategias y tecnologías investigadas han demostrado que es posible
optimizar la eficiencia del uso del agua en parcela. Con la implementación de
sistemas de riego subterráneo se puede reducir el uso consuntivo de agua,
obteniendo ahorros netos en el consumo hídrico. Mediante la estimación de
la dosis de riego a través de sensores de humedad, se mejora la eficiencia en
la aplicación del riego y se reducen así las pérdidas por percolación profunda,
minimizando el lavado de nutrientes y, con ello, el riesgo de contaminación
de los acuíferos. En todo caso, sería recomendable estudiar la viabilidad de
estas propuestas en el contexto global e integral de la gestión de los recursos
hídricos a nivel de un distrito de riego y cuenca hidrográfica. / [CA] La present Tesi Doctoral s'emmarca al voltant de tres eixos que requerix qualsevol reg per a considerar-se eficient: 1) selecció del sistema de distribució d'aigua, 2) determinació de les necessitats de reg i, 3) control de l'estat hídric de la planta.
L'assaig detallat al Capítol II es centrà en la selecció del sistema de reg per degoteig que millor s'adaptara a les particularitats del cultiu dels cítrics. S'estudià la resposta productiva del mandarí (Citrus clementina, Hort. Ex Tan. 'Arrufatina') en funció dels diversos sistemes de reg superficial (SI) i subterrani (SSI) amb 7 (SI7, SSI7) i 14 emissors (SI14, SSI14) per planta disposats en doble línia, així com un tercer tractament subterrani (SSIA), idèntic a SSI7, però equipat amb una línia addicional subterrània col·locada entre fileres d'arbres. L'efecte dels tractaments s'avaluà en xifres de producció, qualitat de la fruita, productivitat de l'aigua (WP) i estalvi d'aigua. Els resultats mostraren que l'estalvi d'aigua amb el sistema SSI poden arribar a ser del 23% en comparació amb SI, sense minves en la producció ni en la qualitat de la fruita, incrementant per tant la WP. El sistema SSIA fou el tractament que emprà menys volum d'aigua de reg i obtingué un major rendiment productiu.
Al Capítol III es proposa una metodologia de càlcul de les necessitats de reg per a mandarins basada en l'ús de sondes d'humitat de tipus capacitiu (e.f. FDR). El procediment de càlcul es definix en tres fases seqüencials: i) determinació de límits d'humitat de sòl adaptats als requeriments de les plantes en diverses fases fenològiques; ii) estandardització de les lectures de les sondes capacitives mitjançant un programa de simulació hidrològica que permet reduir els efectes de la variabilitat intrínseca dels equips; i, per últim, iii) un procediment per a extrapolar els límits d'humitat definits al treball a qualsevol parcel·la amb diferents característiques edàfiques. La validació d'aquesta estratègia en una parcel·la de cítrics (Citrus clementina, Hort. Ex Tan. 'Arrufatina') suposà un estalvi d'aigua del 26% sense reduccions significatives en la producció, millorant la WP un 33%.
Als assajos descrits al Capítol IV es realitza l'avaluació dels sensors de turgència de fulles (Yara ZIM-probe) com a indicadors de l'estat hídric de la planta. Un primer experiment es realitzà en caqui (Diospyros kaki L.f.), avaluant els sensors de turgència en un assaig de camp amb diverses dosis de reg i portaempelts amb diferent tolerància a la sequera [Diospyros lotus (L) i Diospyros virginiana (V)]. La informació que proporcionava el sensor es comparà amb mesures de potencial hídric de tija al migdia solar (¿stem) i variacions del diàmetre de tronc. L'estudi determinà que l'anàlisi visual de les corbes dels valors diaris de Pp és un bon indicador de l'estat hídric de la planta. L'evolució de Pp juntament amb els valors de ¿stem, permeté establir tres estats de turgència associats a estats hídrics concrets. Els arbres insuficientment regats amb ¿stem per baix dels -0.8 MPa, mostraren corbes Pp amb signes d'inversió (valors màxims durant la nit). Així mateix, amb la informació procedent dels sensors fou possible diferenciar l'estat hídric entre patrons, assenyalant a L com el portaempelt més sensible al dèficit hídric. El segon experiment es realitzà en mandarí (Citrus clementina, Hort. Ex Tan. 'Arrufatina'). Els valors de Pp es compararen amb les mesures de ¿stem. En aquest cas, les corbes pràcticament no sofriren inversions quan l'estat hídric era inadequat, però sí es determinà un augment dels valors de Pp mínims i màxims registrats a la nit i al migdia, respectivament. Així mateix, es realitzaren dos cicles de mesures horàries que mostraren que existix una bona correlació entre Pp i ¿stem (coeficient de determinació, r2 = 0.40 -0.74 ).
Les estratègies i tecnologies investigades han demostrat que és possible
optimitzar l’eficiència de l’ús de l’aigua en parcel·la. Amb la implementació de
sistemes de reg subterrani es pot reduir l’ús consumptiu d’aigua, obtenint
estalvis nets en el consum hídric. Amb l’estimació de la dosi de reg mitjançant
sensors d’humitat, es millora l’eficiència en l’aplicació del reg i es reduix així
les pèrdues per percolació profunda, minimitzant el llavat de nutrients, i amb
això, el risc de contaminació dels aqüífers. En tot cas, seria recomanable
estudiar la viabilitat d’aquestes propostes al context global i integral de la
gestió dels recursos hídrics a nivell de districte de reg i conca hidrogràfica. / Martínez Gimeno, MA. (2020). Riego de precisión para la eficiencia hídrica en la agricultura Mediterránea [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/149394 / Compendio
|
89 |
Techniky zavádění nasojejunálních sond / Nasojejunal tube placement techniquesSoučková, Veronika January 2013 (has links)
Author's title and name: Bc. Veronika Součková Institute: Charles University, Prague 1. Faculty of medicine Kateřinská 32, 121 08, Prague 2 Study branch: follow-up Master's - intensive care Study programme: specialization in intensive care Title: Nasojejunal tube placement techniques Consultant: MUDr. František Novák, Ph.D. Number of pages: 81 Number of attachments: 3 Number of tables, grafs and pictures: 24 Year of presentation: 2013 Keywords: Nasojejunal tube, placement techniques, enteral nutrition, endoscopy, fluoroscopy, blind bedside technique This dissertation is dedicated to the issue and options in the field of nasojejunal tubes placement technique. Theoretical part aims at the description of methods and procedures of placing the nasojejunal tube and briefly mentions possible complications and principles of enteral nutrition, which is administrated by this method. Empirical part of the dissertation aims at the comparison of placement the nasojejunal tube using the blind bedside technique developed at intensive care unit in General University Hospital in Prague to, endoscopic and fluoroscopic methods. The research brings description and comparison of the most frequently used methods of placement the feeding tube into the small intestine.
|
90 |
Snímače proudu / Current sensorsVaculík, Vlastimil January 2012 (has links)
This diploma theisis deals with the theoretical analysis of the known types of current sensors, including for example, current transformers, shunts, and advanced sensors using Hall sensor or Rogowski coil. Subsequently, the rest of the work deals with the issue of current transducers with Hall sensors, without using a ferromagnetic circuit. For optimal currnet measure and overall precision, several possible options are designed and calculated. This includes number of sensing elements and distribution of sensors around the wires. Based on calaculation of magnetic intensity, related 3D charts ale plotted unsing Excel software. These charts illustrate the theoretical calculations of field distribution around conductors for various number of sensor. In the last part, components ale designed for practical implementation and scheme of electrical wiring. According to this scheme there is PCB designed as well. Whole current meter ir practically build and its results are compared with theoretical assumtions that are discussed in conclusion part of this theisis.
|
Page generated in 0.0499 seconds