• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Microextração de canabinoides em urina usando dispositivo empacotado com polímero molecularmente impresso e análise por cromatografia líquida - espectrometria de massas sequencial / Microextraction of cannabinoids in urine using device packed with molecularly imprinted polymer and analysis by liquid chromatography - sequential mass spectrometry

Douglas Morisue Sartore 30 July 2018 (has links)
O preparo da amostra é uma das etapas mais importantes em toda a análise química. O isolamento e a concentração dos componentes da amostra são cruciais e busca-se sempre que essas etapas sejam as mais simples e consumam o mínimo possível de tempo e reagentes. Nos últimos anos, um tipo de material tem se mostrado bastante útil para análises químicas a partir de fluidos biológicos, os polímeros molecularmente impressos (MIPs). Os MIPs são sintetizados por reações de polimerização, na presença de uma molécula molde (template). A molécula molde se liga aos monômeros funcionais do polímero durante a reação de polimerização e permanece ligada à superfície das cadeias poliméricas quando a reação se completa. Terminada a polimerização, realiza-se a completa lavagem das moléculas molde, assim, restam na superfície polimérica cavidades tridimensionais complementares à molécula empregada como molde. Essas cavidades permitem a ligação reversível e preferencial da molécula molde ou outras com estrutura química semelhante. A Cannabis sativa é a droga ilícita mais consumida em todo o mundo e nos últimos anos muita atenção tem se voltado a seus efeitos toxicológicos no corpo humano e a aplicações medicinais. Nesta dissertação, foi sintetizado um MIP com a molécula molde catequina para a extração e posterior análise por LC-MS/MS dos canabinóides Δ9-tetrahidrocanabinol (THC), 11-hidroxi-Δ9-tetrahidrocannabinol (THC-OH) e 11-nor-Δ9-tetrahidrocannabinol-9-ácido carboxílico (THC-COOH) em amostras de urina. O MIP produzido foi empacotado em microdispositivo e empregado no preparo das amostras de urina por microextração por sorvente empacotado (MEPS). O método desenvolvido apresentou boa linearidade (valores de r de 0,977 para o THC e 0,994 para THC-OH e THC-COOH). Os limites de detecção e de quantificação foram respectivamente de 5 ng mL-1 e 20 ng mL-1, para os compostos THC e THC-OH, na faixa linear de 25 a 250 ng mL-1. Para o composto THC-COOH os limites de detecção e quantificação alcançados foram de 1 ng mL-1 e 5 ng mL-1, respectivamente, na faixa linear de 5 a 170 ng mL-1. O método apresentou valores razoáveis de precisão entre 3,2% (THC-COOH) e 25,1% (THC) e de exatidão, que variou entre -18,4 e 17,4 (ambos para o THC). O MIP empregado no preparo da amostra mostrou-se mais seletivo e específico do que materiais normalmente empregados para a extração dos canabinoides das amostras de urina, além de a técnica de extração por MEPS apresentar baixo consumo de solventes e amostra para a extração dos analitos e posterior análise por LC-MS/MS. / The sample preparation is one of the most important steps in every chemical analysis. The isolation and concentration of the sample components are crucial and it is always sought that these steps are simple and consume the lowest amount of time and reagents. In the recent years, a type of material has proved to be very useful for chemical analyzes of biological fluids, the molecularly imprinted polymers (MIPs). MIPs are synthesized by polymerization reactions in the presence of a template molecule. The template molecule binds to the functional monomers of the polymer during the polymerization reaction and remains bonded to the surface of the polymeric chains after the reaction is complete. After the polymerization is finished, the complete washing of the template molecules is carried out, thus, three-dimensional cavities, complementary to the molecule used as a template, remain on the polymer surface. These cavities allow the reversible and preferential bonding of the template molecule or others with similar chemical structure. Cannabis sativa is the most commonly consumed illicit drug in the world and in recent years much attention has focused on its toxicological effects on human body and for medical applications. In this master dissertation, a MIP was synthesized with the catechin molecule as template, for extraction and subsequent analysis by LC-MS/MS of the cannabinoids Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. The MIP produced was packed in a microdevice and used in the preparation of the urine samples by microextraction by packed sorbent (MEPS). The developed method showed good linearity (r values of 0.977 for THC and 0.994 for THC-OH and THC-COOH). The detection and quantification limits were respectively 5 ng mL-1 and 20 ng mL-1 for THC and THC-OH in the linear range from 25 to 250 ng mL-1. For the compound THC-COOH the limits of detection and quantification achieved were 1 ng mL-1 and 5 ng mL-1, respectively, in the linear range from 5 to 170 ng mL-1. The method presented reasonable values of precision, between 3.2% (for THC-COOH) and 25.1% (for THC) and displayed accuracy ranging from -18.4 to 17.4 (both for THC). The MIP used in the sample preparation was more selective and specific than other materials usually employed for the extraction of the cannabinoids from the urine samples. The MEPS technique also showed low consumption of solvents and sample for sample preparation, extraction of analytes and subsequent analysis by LC-MS/MS.
12

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Ana Paula Formenton Catai 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
13

Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samples

Fernanda Zampieri Leandro 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.

Page generated in 0.0416 seconds