• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e validação de métodos bioanalíticos para quantificação de hidroclorotiazida e cimetidina em plasma humano e aplicação em estudos da farmacocinética comparada

Eduardo Miranda de Sousa, Carlos 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T16:27:22Z (GMT). No. of bitstreams: 2 arquivo2084_1.pdf: 1052849 bytes, checksum: 5755ac115807355b687973e612634a6e (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / A adoção da Política nacional de Medicamentos Genéricos pelo Governo Federal (Lei n° 9.787 de 10 de fevereiro de 1999) envolve a produção de medicamentos de melhor qualidade, mais seguros e eficazes, comprovados através da realização de testes de equivalência farmacêutica e bioequivalência, contribuindo para aumento do acesso aos medicamentos e fortalecendo a indústria nacional através do desenvolvimento tecnológico. Para isto, é necessário o desenvolvimento e a validação de metodologias analíticas capazes de determinar o fármaco em fluidos biológicos. No Brasil, ainda existe uma carência de recursos humanos qualificados para atender a crescente demanda do mercado. Como colaborador da implementação da política nacional de Medicamentos Genéricos, este trabalho tem por objetivo o desenvolvimento e validação de métodos bioanalíticos para aplicação em estudos de biodisponibilidade relativa de dois fármacos (cimetidina e hidroclorotiazida) em voluntários sadios. Aplicou-se a técnica de extração liquido-liquido para purificação das amostras e para quantificação foi utilizada a cromatografia líquida de alta eficiência com detecção por espectrometria de massas em tandem (CL-EM/EM). Após o desenvolvimento, validação e aplicação das metodologias; os resultados dos parâmetros farmacocinéticos foram obtidos através das curvas de concentração sangüínea do fármaco versus tempo, e analisados estatisticamente para determinação da bioequivalência. Os seguintes parâmetros farmacocinéticos devem ser determinados: ASC, Cmax e Tmax. Os métodos demonstraram-se econômicos, práticos, rápidos, sensíveis, precisos e exatos segundo as normas da ANVISA e da FDA. Portanto, os estudos apresentaram ferramentas adequadas para avaliação das formulações de cimetidina comprimido (teste e referência) e das formulações de hidroclorotiazida comprimido (teste e referência), ambas mostraram-se bioequivalentes
2

Desenvolvimento e validação de metodologias analíticas para estudo farmacocinético comparativo de duas classes de fármacos (anti-retroviral e penicilínico) em individuos sadios

Mota Gonçalves, Talita January 2005 (has links)
Made available in DSpace on 2014-06-12T16:31:33Z (GMT). No. of bitstreams: 2 arquivo6105_1.pdf: 5576311 bytes, checksum: d9a7fdda3c20e4afdddacb6aed7e7b80 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / De acordo com os dados da Organização Mundial da Saúde (OMS), mais de um terço da população mundial não tem acesso a medicamentos. A partir do uso de medicamentos genéricos, um número maior de pessoas poderia ter acesso a medicamentos mais baratos o que ampliaria o padrão de saúde e garantiria mais qualidade de vida. No caso particular de agentes anti-retrovirais e antibióticos, significa um progresso extraordinário no acesso pleno aos direitos humanos e à equidade para a saúde. Para tal, é fundamental a realização de estudos de farmacocinética comparada de fármacos (Bioequivalência) entre o medicamento teste e o medicamento de referência. A introdução, no início dos anos 70, de métodos de análise mais sensíveis, exatos e precisos para a determinação dos princípios ativos dos medicamentos, tanto em matrizes simples como em amostras biológicas, representou um avanço notável na avaliação dos processos de absorção e de sua correlação com os parâmetros de formulação. Conseqüentemente, tornou indispensável o desenvolvimento contínuo de novas metodologias com sensibilidade e seletividade compatíveis com a aplicação em estudos, cada vez mais rigorosos, de bioequivalência/biodisponibilidade de medicamentos. No Brasil, ainda existe uma carência de recursos humanos qualificados para atender à demanda crescente desses estudos. Com o intuito de propor uma alternativa a esse cenário o presente trabalho teve como objetivo o desenvolvimento e a validação de novas metodologias bioanalíticas para a quantificação do anti-retroviral Indinavir e do antibiótico penicilínico Ampicilina, em plasma humano, aplicados na avaliação da qualidade biofarmacêutica de dois diferentes medicamentos. Os fármacos foram submetidos a diferentes tipos de extração e clean up ou limpeza das amostras. Obteve-se uma metodologia validada por cromatografia líquida de alta eficiência acoplada a um detector de Ultravioleta (CLAE-UV) com extração líquido-líquido (ELL) para o Indinavir, e uma metodologia validada por cromatografia líquida de alta eficiência acoplada a espectrômetro de massas (CL-EM/EM) com extração em fase sólida (EFS) para a Ampicilina. Os parâmetros farmacocinéticos como ASC, Cmax e Tmax foram utilizados na avaliação da biodisponibilidade dos medicamentos testados. De acordo com normas do FDA e ANVISA, as metodologias validadas demonstraram praticidade, sensibilidade, precisão e exatidão, apresentando-se como ferramentas adequadas para a avaliação dos estudos farmacocinéticos das formulações de ampicilina cápsulas (teste e referência) e das formulações de indinavir cápsulas (teste e referência), ambos bioequivalentes
3

Análise de estatinas em plasma humano utilizando microextração por dispositivo preenchido com sorvente (MEPS) e cromatografia líquida acoplada à espectrometria de massas sequencial (LC-MS/MS) / Determination of statins in human plasma using microextraction in packed syringe (MEPS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Ortega, Scarlet Nere 20 September 2013 (has links)
As elevadas taxas de colesterol plasmático representam um grande risco à saúde, uma vez que podem causar doenças cardiovasculares. Para o tratamento e prevenção da dislipidemia são utilizados medicamentos reguladores do colesterol, como as estatinas. Embora eficazes e extensamente utilizados, esses fármacos apresentam efeitos adversos se administrados na dosagem errada. Assim, faz-se necessário o desenvolvimento de um método de monitorização terapêutica a fim de se ajustar a concentração desses compostos no sangue. Este trabalho visa o desenvolvimento de um método para análise de pravastatina (PRA), atorvastatina (AT), fluvastatina (FLV) e sinvastatina (SV) em plasma humano usando cromatografia líquida acoplada à espectrometria de massas (LC-MS). Na etapa de preparo de amostras, de forma inédita, utilizou-se a técnica microextração por sorvente empacotado (MEPS) para a análise de plasma humano contendo quatro estatinas. Para a otimização das condições de extração avaliaram-se, por experimentos univariados, parâmetros como fase extratora, composição do solvente de eluição e de lavagem. Outros fatores como volume de amostra, ciclos de amostragem, ciclos de eluição e etapas de eluição foram avaliados empregando-se planejamento experimental multivariado. A extração foi realizada utilizando-se uma fase estacionária C18 Chromabond como sorvente. O método MEPS-LC-MS/MS desenvolvido foi validado baseando-se nas recomendações da agência nacional de vigilância sanitária (ANVISA) e apresentou linearidade, seletividade, precisão, exatidão e recuperação adequadas para as estatinas, excetuando-se para a sinvastatina. A faixa de linearidade obtida foi de 10-200 ng mL-1 (FLV e AT) e 20-200 ng mL-1 (PRA). Os limites de quantificação obtidos foram da ordem de 10 ng mL-1 (AT e FLV) e 20 ng mL-1 (PRA). Desta forma o método desenvolvido poderá ser utilizado para a determinação dos níveis de pravastatina, fluvastatina e atorvastatina em amostras de plasma humano. / Elevated plasma cholesterol level is a risk factor for coronary diseases, which are the most deadly sickness according to the World Health Organization (WHO). In order to fight the hypercholesterolemia in patients, statins are a well-established class of drugs to be prescribed. Even though they are efficient, some side effects can be associated with statin therapy, especially when interactions with other drugs occur. In these cases, monitoring the concentration can optimize the drug dosage to therapeutic effectiveness whilst minimizing the adverse effects. The aim of this work was to develop a method for analysis of pravastatin (PRA), atorvastatin (AT), fluvastatin (FLV) and simvastatin (SV) in human plasma. The experimental means chosen to attain the goal was liquid chromatography-tandem mass spectrometry (LC-MS/MS) and for the sample preparation, microextraction by packed sorbent (MEPS). To optimize the extraction conditions, parameters such as sorbent, elution and washing solution were evaluated. Other parameters such as sampling, elution cycles, sample volume and elution steps were evaluated using multivariate experimental design. The extraction was performed using C18 Chromabond as sorbent. The method was validated based on ANVISA recommendations and featured appropriated linearity, selectivity, accuracy, precision, and recovery, except for simvastatin. The calibration curve in plasma was obtained in the concentration range 10-200 ng mL-1 (FLV and AT) and 20-200 ng mL-1 (PRA) and the limit of quantification (LOQ) was 10 ng mL-1 (FLV and AT) and 20 ng mL-1 (PRA). The method developed proved to be suitable for the analysis of pravastatin, fluvastatin and atorvastatin in human plasma sample, but not simvastatin, and it can contribute to a more efficient usage of the statins in the treatment of hypercholesterolemia.
4

Análise de estatinas em plasma humano utilizando microextração por dispositivo preenchido com sorvente (MEPS) e cromatografia líquida acoplada à espectrometria de massas sequencial (LC-MS/MS) / Determination of statins in human plasma using microextraction in packed syringe (MEPS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Scarlet Nere Ortega 20 September 2013 (has links)
As elevadas taxas de colesterol plasmático representam um grande risco à saúde, uma vez que podem causar doenças cardiovasculares. Para o tratamento e prevenção da dislipidemia são utilizados medicamentos reguladores do colesterol, como as estatinas. Embora eficazes e extensamente utilizados, esses fármacos apresentam efeitos adversos se administrados na dosagem errada. Assim, faz-se necessário o desenvolvimento de um método de monitorização terapêutica a fim de se ajustar a concentração desses compostos no sangue. Este trabalho visa o desenvolvimento de um método para análise de pravastatina (PRA), atorvastatina (AT), fluvastatina (FLV) e sinvastatina (SV) em plasma humano usando cromatografia líquida acoplada à espectrometria de massas (LC-MS). Na etapa de preparo de amostras, de forma inédita, utilizou-se a técnica microextração por sorvente empacotado (MEPS) para a análise de plasma humano contendo quatro estatinas. Para a otimização das condições de extração avaliaram-se, por experimentos univariados, parâmetros como fase extratora, composição do solvente de eluição e de lavagem. Outros fatores como volume de amostra, ciclos de amostragem, ciclos de eluição e etapas de eluição foram avaliados empregando-se planejamento experimental multivariado. A extração foi realizada utilizando-se uma fase estacionária C18 Chromabond como sorvente. O método MEPS-LC-MS/MS desenvolvido foi validado baseando-se nas recomendações da agência nacional de vigilância sanitária (ANVISA) e apresentou linearidade, seletividade, precisão, exatidão e recuperação adequadas para as estatinas, excetuando-se para a sinvastatina. A faixa de linearidade obtida foi de 10-200 ng mL-1 (FLV e AT) e 20-200 ng mL-1 (PRA). Os limites de quantificação obtidos foram da ordem de 10 ng mL-1 (AT e FLV) e 20 ng mL-1 (PRA). Desta forma o método desenvolvido poderá ser utilizado para a determinação dos níveis de pravastatina, fluvastatina e atorvastatina em amostras de plasma humano. / Elevated plasma cholesterol level is a risk factor for coronary diseases, which are the most deadly sickness according to the World Health Organization (WHO). In order to fight the hypercholesterolemia in patients, statins are a well-established class of drugs to be prescribed. Even though they are efficient, some side effects can be associated with statin therapy, especially when interactions with other drugs occur. In these cases, monitoring the concentration can optimize the drug dosage to therapeutic effectiveness whilst minimizing the adverse effects. The aim of this work was to develop a method for analysis of pravastatin (PRA), atorvastatin (AT), fluvastatin (FLV) and simvastatin (SV) in human plasma. The experimental means chosen to attain the goal was liquid chromatography-tandem mass spectrometry (LC-MS/MS) and for the sample preparation, microextraction by packed sorbent (MEPS). To optimize the extraction conditions, parameters such as sorbent, elution and washing solution were evaluated. Other parameters such as sampling, elution cycles, sample volume and elution steps were evaluated using multivariate experimental design. The extraction was performed using C18 Chromabond as sorbent. The method was validated based on ANVISA recommendations and featured appropriated linearity, selectivity, accuracy, precision, and recovery, except for simvastatin. The calibration curve in plasma was obtained in the concentration range 10-200 ng mL-1 (FLV and AT) and 20-200 ng mL-1 (PRA) and the limit of quantification (LOQ) was 10 ng mL-1 (FLV and AT) and 20 ng mL-1 (PRA). The method developed proved to be suitable for the analysis of pravastatin, fluvastatin and atorvastatin in human plasma sample, but not simvastatin, and it can contribute to a more efficient usage of the statins in the treatment of hypercholesterolemia.
5

Avaliação da bioequivalência de formulações contendo lorazepam através de método bioanalítico utilizando a cromatografia líquida acoplada ao sistema de detecção por espectrometria de massa / A bioanalytical method using liquid chromatography coupled to MS/MS detection system for the quantification of Lorazepam in human plasma aiming bioequivalence studies.

Sampaio, Maurício Rocha de Magalhães 17 April 2008 (has links)
Desenvolveu-se método de alta sensibilidade e especificidade por cromatografia liquida de alta eficiência acoplada a detecção por espectrometria de massas (LC-MS/MS) para quantificação do lorazepam em plasma humano visando aplicação em estudo de bioequivalência entre duas formulações de comprimidos contendo esse fármaco. A preparação das amostras de plasma foi feita por extração líquido-líquido usando hexano:diclorometano (60:40 v/v) como solvente de extração. O padrão interno usado foi o bromazepam. A separação cromatográfica ocorreu utilizando-se coluna analítica modelo Gemini® C18 110 A (150 mm x 4,6 mm; partículas de 5µm). Mistura de metanol e tampão acetato de amônio 10 mM (80:20, v/v), acrescida de 0,1% de ácido fórmico ao final da preparação, foi usada como fase móvel. A interface entre HPLC e MS/MS foi a fonte de ionização por eletrospray (ESI) operando em modo positivo (ES+). O analito e o PI foram monitorados e quantificados através de multiple reaction monitoring (MRM). As transições monitoradas foram m/z 320,69 > 274,96 para o lorazepam e m/z 318,00 > 182,20 para o padrão interno. O método foi validado na faixa de concentração de 0,50 a 80,0 ng/ml em plasma humano. A bioequivalência entre as formulações foi determinada através dos intervalos de confiança 90 % obtidos para as razões dos parâmetros farmacocinéticos Cmax (99% - 114%), AUC0-t (93% - 105%) e AUC0-inf (96% - 107%). Concluiu-se que as duas formulações podem ser administradas de maneira intercambiável sem prejuízo da eficácia terapêutica. / A method of liquid chromatography coupled to mass spectrometric detection (LC-MS/MS) with high sensitivity and specificity was developed to quantify Lorazepam in human plasma. This method was applied in a bioequivalence study between two tablet formulations. The preparation of plasma samples were performed by liquid-liquid extraction using hexanedichloromethane (60:40 v/v) as extraction solvent. The internal standard was bromoazepam. The chromatographic separation was achieved using the Gemini® C18 110A (150 mm x 4.6mm; 5µm particles) analytical column. The mobile phase was prepared from a mixture of methanol and 10mM of ammonium acetate (80:20, v/v), and finally adding 0.1% of formic acid. The HPLC and MS/MS interface was the electrospray ionization source (ESI), operating in positive mode (ESI+). The analyte and internal standard were monitored and quantified through multiple reaction monitoring (MRM). The monitored transitions were m/z 320.69 > 274.96 for lorazepam and m/z 318.00 > 182.20 for the internal standard. The method was validated over the range 0.50 to 80.0 ng/mL in human plasma. The bioequivalence between the two formulations was determined inside the 90% confidence interval for the pharmacokinetic parameters, Cmax (99% - 114%), AUC0-t (93% - 105%) and AUC0-inf (96% - 107%). It was concluded that the two formulations can be administered in an interchangeable manner without losing the therapeutic efficiency.
6

Avaliação da bioequivalência de formulações contendo lorazepam através de método bioanalítico utilizando a cromatografia líquida acoplada ao sistema de detecção por espectrometria de massa / A bioanalytical method using liquid chromatography coupled to MS/MS detection system for the quantification of Lorazepam in human plasma aiming bioequivalence studies.

Maurício Rocha de Magalhães Sampaio 17 April 2008 (has links)
Desenvolveu-se método de alta sensibilidade e especificidade por cromatografia liquida de alta eficiência acoplada a detecção por espectrometria de massas (LC-MS/MS) para quantificação do lorazepam em plasma humano visando aplicação em estudo de bioequivalência entre duas formulações de comprimidos contendo esse fármaco. A preparação das amostras de plasma foi feita por extração líquido-líquido usando hexano:diclorometano (60:40 v/v) como solvente de extração. O padrão interno usado foi o bromazepam. A separação cromatográfica ocorreu utilizando-se coluna analítica modelo Gemini® C18 110 A (150 mm x 4,6 mm; partículas de 5µm). Mistura de metanol e tampão acetato de amônio 10 mM (80:20, v/v), acrescida de 0,1% de ácido fórmico ao final da preparação, foi usada como fase móvel. A interface entre HPLC e MS/MS foi a fonte de ionização por eletrospray (ESI) operando em modo positivo (ES+). O analito e o PI foram monitorados e quantificados através de multiple reaction monitoring (MRM). As transições monitoradas foram m/z 320,69 > 274,96 para o lorazepam e m/z 318,00 > 182,20 para o padrão interno. O método foi validado na faixa de concentração de 0,50 a 80,0 ng/ml em plasma humano. A bioequivalência entre as formulações foi determinada através dos intervalos de confiança 90 % obtidos para as razões dos parâmetros farmacocinéticos Cmax (99% - 114%), AUC0-t (93% - 105%) e AUC0-inf (96% - 107%). Concluiu-se que as duas formulações podem ser administradas de maneira intercambiável sem prejuízo da eficácia terapêutica. / A method of liquid chromatography coupled to mass spectrometric detection (LC-MS/MS) with high sensitivity and specificity was developed to quantify Lorazepam in human plasma. This method was applied in a bioequivalence study between two tablet formulations. The preparation of plasma samples were performed by liquid-liquid extraction using hexanedichloromethane (60:40 v/v) as extraction solvent. The internal standard was bromoazepam. The chromatographic separation was achieved using the Gemini® C18 110A (150 mm x 4.6mm; 5µm particles) analytical column. The mobile phase was prepared from a mixture of methanol and 10mM of ammonium acetate (80:20, v/v), and finally adding 0.1% of formic acid. The HPLC and MS/MS interface was the electrospray ionization source (ESI), operating in positive mode (ESI+). The analyte and internal standard were monitored and quantified through multiple reaction monitoring (MRM). The monitored transitions were m/z 320.69 > 274.96 for lorazepam and m/z 318.00 > 182.20 for the internal standard. The method was validated over the range 0.50 to 80.0 ng/mL in human plasma. The bioequivalence between the two formulations was determined inside the 90% confidence interval for the pharmacokinetic parameters, Cmax (99% - 114%), AUC0-t (93% - 105%) and AUC0-inf (96% - 107%). It was concluded that the two formulations can be administered in an interchangeable manner without losing the therapeutic efficiency.
7

DESENVOLVIMENTO E VALIDAÇÃO DE METODOLOGIAS PARA AVALIAÇÃO DE ETORICOXIBE POR CROMATOGRAFIA LÍQUIDA E ESPECTROMETRIA DE MASSAS / DEVELOPMENT AND VALIDATION OF METHODOLOGIES FOR THE EVALUATION OF ETORICOXIB BY LIQUID CHROMATOGRAPHY AND MASS SPECTROMETRY

Brum Junior, Liberato 31 May 2006 (has links)
Etoricoxib is a non-steroidal anti-inflammatory drug, from the coxibs group, that represents a second-generation of COX-2 inhibitors, used for the treatment of arthritis and pain. The methodologies for the evaluation of etoricoxib in pharmaceutical products and plasma were developed and validated in the present work. The reversed-phase liquid chromatography (RP-LC) analysis was carried out using a Synergi fusion C18 column (150 mm x 4.6 mm), maintained at a controlled-ambient temperature. The mobile phase consisted of phosphoric acid 0.01 M, pH 3.0/acetonitrile (62:38, V/V), run at a flow rate of 1.0 mL/min with detection at 234 nm. The chromatographic separation was obtained within 7.0 min and it was linear in the concentration range of 0.02-150 µg/mL. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated using a Luna C18 column (50 mm x 3.0 mm), maintained at 40 ºC and the mobile phase consisted of acetonitrile:water (95:5, V/V)/ 0.1% acetic acid (90:10, V/V), run at flow rate of 0.4 mL/min. The mass spectrometer, equipped with electrospray positive source, was used in multiple reaction monitoring mode (MRM), monitoring the transitions of 359.3>280.0 and 332.0>95.0, for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min and it was linear in the concentration range of 1-5000 ng/mL. The procedures were validated evaluating parameters such as the specificity, linearity, precision, accuracy, robustness, limit of detection and limit of quantitation. Besides, for the bioanalytical method, the matrix effects, recovery and stability studies were also analyzed, giving results within the acceptable range. The proposed methods were applied for the analysis of pharmaceutical products, showing significant correlation (r=0.9999) of the results. Moreover, the liquid-liquid and solid phase extraction methods developed and optimized allowed high mean recoveries of etoricoxib and internal standard from the plasma samples. The procedures can be applied for the biovailability studies and for the quality control of pharmaceutical products. / Etoricoxibe é um antiinflamatório não esteroidal, pertencente ao grupo dos coxibes, que representa a segunda geração dos inibidores seletivos da cicloxigenase-2. É indicado para o tratamento de artrites e dor aguda. No presente trabalho foram desenvolvidas e validadas metodologias para avaliação de etoricoxibe em produtos farmacêuticos e plasma humano. As análises por cromatografia líquida em fase reversa (CL-FR) foram realizadas utilizando coluna Synergi fusion C18 (150 mm x 4,6 mm), mantida a temperatura ambiente. A fase móvel foi composta de ácido fosfórico 0,01 M, pH 3,0/acetonitrila (62:38, V/V) na vazão de 1,0 mL/min e detecção no ultravioleta a 234 nm. A separação cromatográfica foi obtida no tempo de 7 minutos, sendo linear na faixa de concentração de 0,02-150 µg/mL. Paralelamente, desenvolveu-se e validou-se método por cromatografia líquida combinada à espectrometria de massas (CL-EM/EM). Realizaram-se as análises utilizando Luna C18 (50 mm x 4,6 mm), mantida a 40 ºC e fase móvel composta de acetonitrila:água (95:5, V/V)/ 0,1% ácido acético (90:10, V/V), na vazão de 0,4 mL/min. O espectrômetro de massas, equipado com fonte de electrospray positivo, foi empregado no modo de monitoramento de reação múltipla (MRM), monitorando as transições de 359,3>280,0 e 332,0>95,0, para o etoricoxibe e piroxicam (padrão interno), respectivamente. A separação cromatográfica foi obtida em 2 minutos, sendo linear na faixa de concentração de 1-5000 ng/mL. Os procedimentos foram validados, avaliando-se os parâmetros de especificidade, linearidade, precisão, exatidão, robustez, limite de detecção e quantificação, incluindo para o método bioanalítico os efeitos de matriz, a recuperação e estudos de estabilidade, cujos resultados cumpriram os requisitos preconizados. Os métodos propostos foram utilizados na análise de produtos farmacêuticos, demonstrando correlação significativa dos resultados (r=0,9999). Além disso, os métodos de extração líquido-líquido e em fase sólida desenvolvidos e otimizados propiciaram significativas percentagens de recuperação do etoricoxibe e do padrão interno nas amostras de plasma. Os procedimentos pesquisados podem ser aplicados para estudos de biodisponibilidade e para aprimorar o controle da qualidade de medicamentos.
8

DESENVOLVIMENTO E VALIDAÇÃO DE METODOLOGIAS PARA AVALIAÇÃO DE EZETIMIBA POR CROMATOGRAFIA LÍQUIDA E ESPECTROMETRIA DE MASSAS / DEVELOPMENT AND VALIDATION OF METHODOLOGIES FOR THE EVALUATION OF EZETIMIBE BY LIQUID CHROMATOGRAPHY AND MASS SPECTROMETRY

Oliveira, Paulo Renato de 30 March 2007 (has links)
Ezetimibe selectively inhibits the intestinal absorption of dietary cholesterol and related plant sterols, from the 2-azetidinones group, and is used for the treatment of hypercholesterolemia and phytosterolemia. The methodologies for the evaluation of ezetimibe in pharmaceutical products and plasma were developed and validated in the present work. The reversed-phase liquid chromatography (RP-LC) analysis was carried out using a Synergi fusion C18 column (150 mm x 4.6 mm), maintained at 45 oC. The mobile phase consisted of potassium phosphate buffer 0.03 M, pH 4.5/acetonitrile (35:65, V/V), run at a flow rate of 0.6 mL/min with detection at 234 nm. The chromatographic separation was obtained within 15 min and it was linear in the concentration range of 0.5-200 Hg/mL. The method was sucessfuly applied for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical products. The liquid chromatography-tandem mass spectrometry (LCMS/ MS) method was developed and validated using a Luna C18 column (50 mm x 3.0 mm) and the mobile phase consisted of acetonitrile:water (85:15, V/V), run at a flow rate of 0.4 mL/min. The mass spectrometer, equipped with electrospray positive source, was used in multiple reaction monitoring mode (MRM), monitoring the transitions of 392.0>161.0 and 359.3>280.0, for ezetimibe and etoricoxib (internal standard), respectively. The chromatographic separation was obtained within 2 min and it was linear in the concentration range of 0.25-20 ng/mL (ezetimibe) and 1-300 ng/mL (ezetimibe and its glucuronide matabolite). The procedures were validated evaluating parameters such as the specificity, linearity, precision, accuracy, robustness, limit of detection and limit of quantitation. Besides, for the bioanalytical method, the matrix effects, recovery and stability studies were also analyzed, giving results within the acceptable range. The proposed method was applied for the analysis of pharmaceutical products, showing significant correlation (P>0.05) of the results. Moreover, the liquid-liquid extraction method developed and optimized allowed high mean recoveries of ezetimibe and internal standard from the plasma samples. The procedures can be applied for the biovailability studies and for the quality control of pharmaceutical products. / Ezetimiba é um inibidor seletivo da absorção intestinal do colesterol e de fitosteróis, pertencente ao grupo das 2-ezetidinonas, indicado para o tratamento da hipercolesterolemia e fitosterolemia. No presente trabalho foram desenvolvidas e validadas metodologias para avaliação de ezetimiba em produtos farmacêuticos e plasma humano. As análises por cromatografia líquida em fase reversa (CL-FR) foram realizadas utilizando coluna Synergi fusion C18 (150 mm x 4,6 mm), mantida a 45 oC. A fase móvel foi composta de tampão fosfato de potássio 0,03 M, pH 4,5/acetonitrila (35:65, V/V), eluída na vazão de 0,6 mL/min e detecção no ultravioleta a 234 nm. A separação cromatográfica foi obtida no tempo de 15 minutos, sendo linear na faixa de concentração de 0,5-200 Hg/mL. O método foi aplicado para análise simultânea de ezetimiba e sinvastatina em produtos farmacêuticos comerciais. Paralelamente, desenvolveu-se e validou-se método por cromatografia líquida combinada à espectrometria de massas (CL-EM/EM). Executaram-se as análises utilizando coluna Luna C18 (50 mm x 4,6 mm) e fase móvel composta de acetonitrila:água (85:15, V/V) na vazão de 0,4 mL/min. O espectrômetro de massas, equipado com fonte de electrospray positivo, foi empregado no modo de monitoramento de reação múltipla (MRM), monitorando as transições de 392,0>161,0 e 359,3>280,0, para a ezetimiba e etoricoxibe (padrão interno), respectivamente. A separação cromatográfica foi obtida em 2 minutos, sendo linear nas faixas de concentração de 0,25-20 ng/mL (ezetimiba) e 1-300 ng/mL (ezetimiba e seu metabólito). Os procedimentos foram validados, avaliando-se os parâmetros de especificidade, linearidade, precisão, exatidão, robustez, limite de detecção e quantificação, incluindo para o método bioanalítico os efeitos de matriz, recuperação e estudos de estabilidade, cujos resultados cumpriram os requisitos preconizados. O método proposto foi utilizado na análise de produtos farmacêuticos, demonstrando correlação significativa dos resultados (P>0,05). Além disso, o método de extração líquido-líquido desenvolvido e otimizado propiciou significativa percentagem de recuperação da ezetimiba, seu metabólito e do padrão interno nas amostras de plasma. Os procedimentos pesquisados podem ser aplicados para estudos de biodisponibilidade e para aprimorar o controle da qualidade de medicamentos.
9

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Catai, Ana Paula Formenton 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
10

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Ana Paula Formenton Catai 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.

Page generated in 0.4544 seconds